Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “spectrometry data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Mapping Soil Cation‐Exchange Capacity using Bayesian Modeling and Proximal Sensors at the Field Scale

Core Ideas A Bayesian inference approach (INLA‐SPDE) was used to map topsoil and subsoil CEC. DEM, gamma‐ray spectrometer and EM induction data were combined to map CEC. Posterior marginal distributions of the model parameters and responses were estimated. Gamma‐ray data performed best in the topsoil, followed by DUALEM421S and elevation. Elevation data performed best in the subsoil, followed by gamma‐ray and DUALEM421S. Cation exchange capacity (CEC) affects soil fertility, acidity, and structural resilience. This is particularly the case in sugarcane growing areas of Australia because the soil there is sandy (>60%), strongly acidic (pH < 5.5), and strongly sodic (exchangeable sodium percentage [ESP] > 15%). Unfortunately, obtaining information on CEC at the field extent is time‐consuming and expensive. Here, we used a digital soil mapping approach to add value to limited (40) topsoil (0–0.3 m) and subsoil (0.6–0.9 m) CEC information. We first collected proximally sensed ancillary data from three sources, including a digital elevation model (DEM), γ‐ray (γ‐ray) spectrometer (RS700) and electromagnetic (EM) induction instruments. We then use a Bayesian inference approach (Integrated Nested Laplace Approximation with Stochastic Partial Differential Equation, INLA‐SPDE) implemented in R software to model the CEC and ancillary data. Accuracy (RMSE), bias (ME), and concordance (Lin's) of models were also generated from the different sources of ancillary data, either in combination or alone. We concluded, overall, that the INLA–SPDE approach could provide estimations of the posterior marginal distributions of the model parameters as well as the model responses as reported by other researchers. We also concluded that using the ancillary data sources in combination was most accurate (e.g., RMSE = 0.72) to predict CEC, least biased (e.g., ME = 0.07) and had the highest concordance (e.g., Lin's = 0.69) in both the topsoil and subsoil than using the ancillary data alone. The best ancillary data, when used alone for mapping CEC in the topsoil, was γ‐ray spectrometry, followed by EM data and elevation. For subsoil CEC, it was elevation, followed by γ‐ray spectrometry and then soil electrical conductivity (EC a ) data. The maps of the credibility interval (CI) indicated that better predictions were achieved in the topsoil and indicated where improvements in prediction could be achieved in the subsoil.

Li, Nan↗

A fast data acquisition system for the study of transient events by high repetition rate time-of-flight mass spectrometry

Recent advances in commercially available data acquisition electronics embodying high speed A/D conversion coupled to increased memory storage have now made practical (at least within time intervals of a third of a millisecond or more) the capturing of all of the data generated by a high repetition rate time-of-flight mass spectrometer producing complete spectra every 25 to 35 microseconds. Such a system was assembled and interfaced with a personal computer for control and management of data. The applications are described for recording time-resolved spectra of individual vapor plumes induced from the pulsed-laser heating of material. Each laser pulse triggers the system to generate automatically a 3-dimensional (3-D) presentation of the time-resolved spectra with m/z labeling of the major mass peaks, plus an intensity versus time display of both the laser pulse and the resulting vapor pulse. The software also permits storing of data and its presentation in various additional forms.

Lincoln, K. A.↗

Acquisition and processing of data for isotope-ratio-monitoring mass spectrometry

Methods are described for continuous monitoring of signals required for precise analyses of 13C, 18O, and 15N in gas streams containing varying quantities of CO2 and N2. The quantitative resolution (i.e. maximum performance in the absence of random errors) of these methods is adequate for determination of isotope ratios with an uncertainty of one part in 10(5); the precision actually obtained is often better than one part in 10(4). This report describes data-processing operations including definition of beginning and ending points of chromatographic peaks and quantitation of background levels, allowance for effects of chromatographic separation of isotopically substituted species, integration of signals related to specific masses, correction for effects of mass discrimination, recognition of drifts in mass spectrometer performance, and calculation of isotopic delta values. Characteristics of a system allowing off-line revision of parameters used in data reduction are described and an algorithm for identification of background levels in complex chromatograms is outlined. Effects of imperfect chromatographic resolution are demonstrated and discussed and an approach to deconvolution of signals from coeluting substances described.

NASA Discipline Exobiology↗

MZA: A Data Conversion Tool to Facilitate Software Development and Artificial Intelligence Research in Multidimensional Mass Spectrometry

Modern mass spectrometry-based workflows employing hybrid instrumentation and orthogonal separations collect multidimensional data, potentially allowing deeper understanding in omics studies through adoption of artificial intelligence methods. However, the large volume of these rich data challenges existing data storage and access technologies, therefore precluding informatics advancements. Here we present MZA™ (pronounced m-za), the mass-to-charge (m/z) generic data storage and access tool designed to facilitate software development and artificial intelligence research in multidimensional mass spectrometry measurements. Composed by a data conversion tool and a simple file structure based on the HDF5 format, MZA provides easy, cross-platform and efficient programmatic access to raw MS-data, enabling fast development of new tools in data science programming languages such as Python and R. The software executable and example Python and R scripts are freely available at https://github.com/PNNL-m-q/mza.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Design and implementation of a data analysis pipeline for paper spray ionization mass spectrometry of UO 2 Cl 2

Ambient mass spectrometry is an emerging characterization method for nuclear materials analysis. SRNL has recently acquired a new JEOL AccuTOF™-DART® LP 4G with a Filter Spray™ front end sample injection system, to develop new methods for ambient mass spectrometry of uranium analytes. Preliminary measurements of uranium-containing samples have demonstrated a need to rapidly evaluate large datasets generated with tailored data analysis scripts. To address this gap a data analysis pipeline written in R within the R Studio environment has been developed. The pipeline comprises a series of processing steps where the data are ingested, analyte peaks of interest are extracted, subsequent ratio and normalization calculations are performed, and results are presented in a series of graphical plots. In detail, the data files containing up to several hundred chronological spectra of a single sample in netCDF format were first extracted into RStudio. Then, initial 3D plots of the data were created in respect to the time, intensity, and mass to charge domains. These graphics serve as an initial easily visualized survey of instrument data. Next, a .csv format file containing the names, masses, and abundances of isotopes of interest were ingested into RStudio and were used to automatically collect intensity values at the mass value. Uranium isotope ratios were plotted against gadolinium isotope ratios (gadolinium was used as an internal standard) and assessed for ion beam stability and intensity. The spectra were filtered by applying a threshold intensity for the 158GdO+ mass channel. A Monte Carlo experiment was performed by creating a theoretical distribution of the data in order to determine the ratio of the uranium isotopes. The results show that the developed data analysis pipeline successfully filters high quality data from overall poor quality runs. Our results also support the idea that paper spray ionization mass spectrometry can be used for both detection and quantification of trace amounts of uranium compounds.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Integrated Algorithms for High-Throughput Examination of Covalently Labeled Biomolecules by Structural Mass Spectrometry

Mass spectrometry based structural proteomics approaches for probing protein structures are increasingly gaining in popularity. The potential for such studies is limited because of the lack of analytical techniques for the automated interpretation of resulting data. In this article, a suite of algorithms called ProtMapMS is developed, integrated, and implemented specifically for the comprehensive automatic analysis of mass spectrometry data obtained for protein structure studies using covalent labeling. The functions include data format conversion, mass spectrum interpretation, detection, and verification of all peptide species, confirmation of the modified peptide products, and quantification of the extent of peptide modification. The results thus obtained provide valuable data for use in combination with computational approaches for protein structure modeling. The structures of both monomeric and hexameric forms of insulin were investigated by oxidative protein footprinting followed by high-resolution mass spectrometry. The resultant data was analyzed both manually and using ProtMapMS without any manual intervention. The results obtained using the two methods were found to be in close agreement and overall were consistent with predictions from the crystallographic structure.

59 BASIC BIOLOGICAL SCIENCES↗

An Automated Platform for High-Resolution Tissue Imaging Using Nanospray Desorption Electrospray Ionization Mass Spectrometry

An automated platform has been developed for acquisition and visualization of mass spectrometry imaging (MSI) data using nanospray desorption electrospray ionization (nano-DESI). The new system enables robust operation of the nano-DESI imaging source over many hours. This is achieved by controlling the distance between the sample and the probe by mounting the sample holder onto an automated XYZ stage and defining the tilt of the sample plane. This approach is useful for imaging of relatively flat samples such as thin tissue sections. Custom software called MSI QuickView was developed for visualization of large data sets generated in imaging experiments. MSI QuickView enables fast visualization of the imaging data during data acquisition and detailed processing after the entire image is acquired. The performance of the system is demonstrated by imaging rat brain tissue sections. High resolution mass analysis combined with MS/MS experiments enabled identification of lipids and metabolites in the tissue section. In addition, high dynamic range and sensitivity of the technique allowed us to generate ion images of low-abundance isobaric lipids. High-spatial resolution image acquired over a small region of the tissue section revealed the spatial distribution of an abundant brain metabolite, creatine, in the white and gray matter that is consistent with the literature data obtained using magnetic resonance spectroscopy.

Environmental Molecular Sciences Laboratory↗

Data and scripts associated with a manuscript investigating dissolved organic matter and microbial community linkages across seven globally distributed rivers

This data package is associated with the publication “Meta-metabolome ecology reveals that geochemistry and microbial functional potential are linked to organic matter development across seven rivers” submitted to Science of the Total Environment. This data package includes the data necessary to replicate the analyses presented within the manuscript to investigate dissolved organic matter (DOM) development across broad spatial distances and within divergent biomes. Specifically, we included the Fourier transform ion cyclotron mass spectrometry (FTICR-MS) data, geochemistry data, annotated metagenomic data, and results from ecological null modeling analyses in this data package. Additionally, we included the scripts necessary to generate the figures from the manuscript. Complete metagenomic data associated with this data package can be found at the National Center for Biotechnology (NCBI) under Bioproject PRJNA946291. This dataset consists of (1) four folders; (2) a file-level metadata (flmd) file; (3) a data dictionary (dd) file; (4) a factor sheet describing samples; and (5) a readme. The FTICR Data folder contains (1) the processed Fourier transform ion cyclotron mass spectrometry (FTICR-MS) data; (2) a transformation-weighted characteristics dendrogram generated from the FTICR-MS data; and (3) the script used to generate all FTICR-MS related figures. The Geochemical Data folder contains (1) the single geochemistry data file and (2) the R script responsible for generating associated figures. The Metagenomic Data folder contains (1) annotation information across different levels; (2) carbohydrate active enzyme (CAZyme) information from the dbCAN database (Yin et al., 2012); (3) phylogenetic tree data (FASTAs, alignments, and tree file); and (4) the scripts necessary to analyze all of these data and generate figures. The Null Modeling Data folder contains (1) data generated during null modeling for each river and all rivers combined and (2) the R scripts necessary to process the data. All files are .csv, .pdf, .tsv, .tre, .faa, .afa, .tree, or .R.

54 ENVIRONMENTAL SCIENCES↗

High-resolution ultrahigh-pressure long column reversed-phase liquid chromatography for top-down proteomics

We report development of an approach providing high-resolution RPLC of proteins and its utility for mass spectrometry-based top-down proteomics. A chromatographic peak capacity of ~450 was achieved for proteins and large polypeptides having MWs up to 43 kDa in the context of proteomics applications. RPLC column lengths from 20 to 200 cm, particle sizes from 1.5 to 5 m, bonding alkyl chains from C1 to C2, C4, C8, and C18, and particle surface structures that spanned porous, superficially porous (porous shell, core-shell), and nonporous were investigated at pressures up to14K psi. Column length was found as the most important factor for >20 kDa proteins in gradient RPLC, and shortening column length degraded RPLC resolution and sensitivity regardless of the size and surface structure of the packing particles used. The alkyl chains bonded to the silica particle surface significantly affected the RPLC recovery and efficiency, and short alkyl C1-C4 phases provided higher sensitivity and resolution than C8 and C18 phases. Long gradient separations (e.g., >10 hours) with long columns (e.g., 100 cm) were particularly effective in conjunction with use of high accuracy mass spectrometers (e.g., the Orbitrap Elite) for top-down proteomics with improved proteoform coverage by allowing multiple HCD, CID, and ETD dissociation modes. It was also found that HCD produced small fragments useful for proteoform identification, while low energy CID and ETD often complemented HCD by providing large fragments.

columns and stationary phases↗

A Preprocessing Tool for Enhanced Ion Mobility–Mass Spectrometry-Based Omics Workflows

The ability to improve the data quality of ion mobility–mass spectrometry (IM-MS) measurements is of great importance for enabling modular and efficient computational workflows and gaining better qualitative and quantitative insights from complex biological and environmental samples. We developed the PNNL PreProcessor, a standalone and user-friendly software housing various algorithmic implementations to generate new MS-files with enhanced signal quality and in the same instrument format. Different experimental approaches are supported for IM-MS based on Drift-Tube (DT) and Structures for Lossless Ion Manipulations (SLIM), including liquid chromatography (LC) and infusion analyses. The algorithms extend the dynamic range of the detection system, while reducing file sizes for faster and memory-efficient downstream processing. Specifically, multidimensional smoothing improves peak shapes of poorly defined low-abundance signals, and saturation repair reconstructs the intensity profile of high-abundance peaks from various analyte types. Further, other functionalities are data compression and interpolation, IM demultiplexing, noise filtering by low intensity threshold and spike removal, and exporting of acquisition metadata. Several advantages of the tool are illustrated, including an increase of 19.4% in lipid annotations and a two-times faster processing of LC-DT IM-MS data-independent acquisition spectra from a complex lipid extract of a standard human plasma sample. The software is freely available at https://omics.pnl.gov/software/pnnl-preprocessor.

59 BASIC BIOLOGICAL SCIENCES↗

Flying Cages in Traveling Wave Ion Mobility: Influence of the Instrumental Parameters on the Topology of the Host–Guest Complexes

Supramolecular mass spectrometry has emerged in the last decade as an orthogonal method to access, at the molecular level, the structures of noncovalent complexes extracted from the condensed phase to the rarefied gas phase using electrospray ionization. It is often considered that the soft nature of the ESI source confers to the method the capability to generate structural data comparable to those in the condensed phase. In the present paper, using the ammonium ion/cucurbituril combination as a model system, we investigate using ion mobility and computational chemistry the influence of the instrumental parameters on the topology, i.e., internal versus external association, of gaseous host/guest complex ions. MS and theoretical data are confronted to condensed phase data derived from nuclear magnetic resonance spectroscopy to assess whether the instrumental parameters can play an insidious role when trying to derive condensed phase data from mass spectrometry results. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Screening Fuels for Autoignition with Small-Volume Experiments and Gaussian Process Classification

Partially reacting candidate fuels under highly dilute conditions across a range of temperatures provides a means to classify the candidates based on traditional ignition characteristics using much lower quantities (sub-mL) than the full octane tests. Using a classifier based on a Gaussian Process model, synthetic species profiles obtained by plug flow reactor simulations at seven temperatures are used to demonstrate that the configuration can be used to classify 95% of the samples correctly for autoignition sensitivity exceeding a threshold (S = 8) and 100%of the samples correctly for research octane number exceeding a threshold (RON = 90). Molecular beam mass spectrometry (MBMS) experimental data at four temperatures is then used as the model input in a real-world test. Despite the nontrivial relationship between the MBMS measurements and speciation as well as experimental noise it is still possible to classify 95% of the samples correctly for RON and 85% of the samples correctly for S in a 'leave-one-out' cross validation exercise. The test data set consists of 45 fuels and includes a variety of primary reference fuels, ethanol blends and other oxygenates.

33 ADVANCED PROPULSION SYSTEMS↗

Cell-Type-Specific Proteomics Analysis of a Small Number of Plant Cells by Integrating Laser Capture Microdissection with a Nanodroplet Sample Processing Platform

Plant organs and tissues contain multiple cell types, which are well organized in 3-dimensional structure to efficiently perform physiological functions such as homeostasis, response to environmental perturbation, pathogen infection. It is critically important to perform molecular measurements at the cell-type-specific level to discover mechanisms and unique features of cell populations that govern differentiation and respond to external perturbations. Although mass spectrometry-based proteomics has been demonstrated as an enabling discovery tool to study plant physiology, conventional approaches require millions of cells to generate robust biological conclusions. Such requirements mask the cell-to-cell heterogeneities and limit the comprehensive profiling of plant proteins at spatially resolved and cell-type-specific resolutions. This protocol describes a recently-developed proteomics workflow for studying a small number of plant cells by integrating laser capture microdissection, microfluidic nanodroplet-based sample preparation, with ultrasensitive liquid chromatography-mass spectrometry. Using poplar as a model tree species, we provide detailed protocols, including plant tissue harvest, tissue preparation, cryosectioning, laser microdissection, protein digestion, mass spectrometry measurement, and data analysis. We show the workflow enables the precise identification and quantification of thousands of proteins from hundreds of isolated plant root and leaf cells.

59 BASIC BIOLOGICAL SCIENCES↗

Proteomics Analysis of Human Contaminant Proteins

Complete characterization of unknowns via proteomics remains challenging. There exist regions of mass spectrometry-based proteomics data where empirical measurements are not attributed to peptides, and/or sequenced peptides from mass spectra are not attributed to any source. These uncharacterized regions are known as the “dark” proteome. Many proteomics tools rely on some a priori knowledge of sample composition; few tools allow for investigation of unknowns without relying on composition assumptions. Further, the potential low abundance of minor traces in these uncharacterized regions can make elucidation of the “dark” proteome challenging. Herein, we describe the development and evaluation of approaches to study the “dark” proteome and move towards an untargeted approach for more complete characterization, namely by studying minor human protein traces in non-human samples and combining that approach with non-human source organism identification without relying on assumptions. Human protein markers, in the form of genetically variant peptides, have been extensively examined in a variety of human matrices, including blood, plasma, and hair, but have yet to be investigated in non-human samples, such as cell cultures, as human contaminant traces. Genetically variant peptides are those that are found in proteins carrying single nucleotide polymorphisms. In this work, we aimed to (1) investigate the feasibility of detecting human contaminant genetically variant peptides (GVPs) in a diverse set of non-human organisms using public proteomics data and a computational pipeline, as well as to (2) develop a combined capability for untargeted source organism characterization and GVP detection. To our knowledge, this is the first report of applying these approaches towards a more complete proteomic characterization of unknowns. We successfully demonstrate the feasibility of broad human contaminant GVP detection in proteomics data, develop a better understanding of GVP detectability, characterize the sample-to-sample variability in GVP detection, and identify a core set of GVPs that can potentially be used as markers indicative of the human contaminant traces portion of the “dark” proteome. Further, we developed and evaluated a combined pipeline, MARLOWE-GVP, that enables both untargeted source organism characterization and GVP detection. We show high accuracy of correct source organism characterization and high degree of similarity of human contaminant GVP detection compared to the conventional approach. Success on both these efforts have allowed us to advance our understanding and characterization of the “dark” proteome.

59 BASIC BIOLOGICAL SCIENCES↗

Characterization techniques for TRU waste from the Analytical Laboratory Hot Cells at Idaho National Laboratory

Characterization techniques for TRU waste from the Analytical Laboratory Hot Cells at Idaho National Laboratory Since the first reactor went hot in 1942, there has been a never ending desire to improve the nuclear reactor and the fuel that it burns. The Idaho National Laboratory has been a key player in reactor and fuel development. As more research projects begin, the spectrum of waste parameters grows. Over the years, the Analytical Laboratory (AL) at the Materials and Fuels Complex (MFC) at Idaho National Laboratory (INL) has supported a large range of various research projects. Each project brings its own challenge and analytical technique that, in turn, yields its own unique waste parameters. The AL Hot Cells at INL consist of 6 small cells that can support around 12 different fuel research projects at a time along with infrastructure and environmental samples. Each different project yields different levels of transuranic (TRU) material, RCRA constituents, dose, and contamination levels. The waste parameters from each project dictate a path forward for the waste Low-Level Waste (LLW), Contact Handled TRU (CH-TRU), Mixed Contact Handled TRU (M-CH-TRU), Remote Handled TRU (RH-TRU), or Mixed Remote Handled TRU (M-RH-TRU). With visual examination techniques and process knowledge as an aid, there have been waste handling methods developed that allow debris and sample material to be segregated. Unique characterization mechanisms have been applied for each debris and sample material that are generally more accurate than smear and surface contamination data. For debris found in the Hot Cells, analytical data is gathered and conservatively summarized for each fuel type and research method. This consists of data from Quadrupole Inductively Coupled Plasma Mass Spectrometry (Q-ICP-MS), Gamma Spectroscopy, and some data verification through Thermal Ionization Mass Spectrometry (TIMS) and Multi-Collector Inductively Coupled Plasma Mass Spectrometry (MC-ICP-MS). This data gives a range of TRU isotope concentrations. Fuel age is taken into account to determine the dominant TRU activity isotopes. Cesium concentrations are also gathered. Each parameter/fuel type then ties a measured Cesium number to TRU content based on historical analytical data. Debris in the hot cells is segregated by project and packaged in individual 2 gallon metal paint cans. Each can is counted by gamma spectroscopy in a calculated and measured geometry. Using process knowledge to determine the fuel or project type, newly counted cesium numbers can be applied to the historic analytical data and TRU content can be estimated. The TRU content allows waste debris to be segregated between CH-TRU and RH-TRU. Packaging techniques can allow for the minimization if RH-TRU waste. Sample material received into the AL must be dissolved into a liquid matrix in order to be analyzed in most cases. When analysis is complete, these liquids go through a consolidation, complexation, neutralization, and solidification process where real time analytical data can be used to calculate TRU content and RCRA constitutes. These calculations allow for no further analytical data to be gathered. The waste matrix is considered stable and acceptable by all AK [define AK] documents. The unique techniques used in characterizing and handling the Analytical Laboratories Hot Cell waste can be applied to various situations and various laboratories. They allow for more accurate data for waste constituents and also for the minimization of RH-TRU waste.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Characterization Techniques for TRU Waste from the Analytical Laboratory Hot Cells at Idaho National Laboratory - 19610

Since the first reactor went hot in 1942, there has been a never ending desire to improve the nuclear reactor and the fuel that it burns. The Idaho National Laboratory has been a key player in reactor and fuel development. As more research projects begin, the spectrum of waste parameters grows. Over the years, the Analytical laboratory (AL) at the INL Materials and Fuels Complex (MFC) has supported a large range of various research projects. Each project brings its own challenge and analytical technique that, in turn, yields its own unique waste parameters. The AL Hot Cells at INL consist of 6 small cells that can support around 12 different fuel research projects at a time along with infrastructure and environmental samples. Each different project yields different levels of transuranic (TRU) material, RCRA constituents, dose, and contamination levels. The waste parameters from each project dictate a path forward for the waste as Low-Level Waste (LLW), Contact Handled TRU (CH-TRU), Mixed Contact Handled TRU (M-CH-TRU), Remote Handled TRU (RH-TRU), or Mixed Remote Handled TRU (M-RHTRU). With visual examination techniques and process knowledge as an aid, there have been waste handling methods developed that allow debris and sample material to be segregated. Unique characterization mechanisms have been applied for each debris and sample material that are generally more accurate than smear and surface contamination data. For debris found in the Hot Cells, analytical data is gathered and conservatively summarized for each fuel type and research method. This consists of data from Quadrupole Inductively Coupled Plasma Mass Spectrometry (Q-ICP-MS), Gamma Spectroscopy, and some data verification through Thermal Ionization Mass Spectrometry (TIMS) and Multi-Collector Inductively Coupled Plasma Mass Spectrometry (MC-ICP-MS). This data gives a range of TRU isotope concentrations. Fuel age is taken into account to determine the dominant TRU activity isotopes. Cesium concentrations are also gathered. Each parameter/fuel type then ties a measured Cesium number to TRU content based on historical analytical data. Debris in the hot cells is segregated by project and packaged in individual 2 gallon metal paint cans. Each can is counted by gamma spectroscopy in a calculated and measured geometry. Using process knowledge to determine the fuel or project type, newly counted cesium numbers can be applied to the historic analytical data and TRU content can be estimated. The TRU content allows waste debris to be segregated between CH-TRU and RH-TRU. Packaging techniques can allow for the minimization of RHTRU waste. Sample material received into the AL must be dissolved into a liquid matrix in order to be analyzed in most cases. When analysis is complete, these liquids go through a consolidation, complexation, neutralization, and solidification process where real time analytical data can be used to calculate TRU content and RCRA constitutes. These calculations allow for no further analytical data to be gathered. The waste matrix is considered stable and acceptable by all Acceptable Knowledge (AK) documents. The unique techniques used in characterizing and handling the Analytical Laboratories Hot Cell waste can be applied to various situations and various laboratories. They allow for more accurate data for waste constituents and also for the minimization of RH-TRU waste. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

WHONDRS Surface Water Geochemistry and Organic Matter Characterization Data from Streams Distributed across Latin America

This dataset supports a broader study examining global transferability of stream biogeochemistry and was generated in collaboration with the MicroSudAqua (µSudAqua) network (https://microsudaqua.netlify.app/en/). The dataset provides surface water geochemistry (dissolved organic carbon, total dissolved nitrogen, cations) and organic matter characterization (FTICR-MS) from streams in Argentina, Brazil, Chile, and Colombia. Samples were collected across stream orders (1st to 6th order) within five basins. Related data were collected and will be published separately in collaboration with the µSudAqua network. For details on how to navigate data packages generated by this project, see https://data.ess-dive.lbl.gov/portals/PNNLRiverCorridorSFA/About. In addition to this readme, this data package also includes a file-level metadata (FLMD) file that describes each file and a data dictionary (DD) that describes all column/row headers and variable definitions. This dataset is comprised of (1) a folder of field photos; (2) a folder of surface water sample data, (3) a folder of raw Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS) data; (4) file-level metadata; (5) data dictionary; (6) field metadata; (7) readme; (8) international generic sample number (IGSN) mapping file; and (9) field protocol. The sample data subfolder contains (1) dissolved organic carbon (DOC, measured as non-purgeable organic carbon, NPOC) data and averages; (2) total dissolved nitrogen data and averages; (3) anions and averages; (4) methods codes; (5) FTICR-MS methods; and (15) a subfolder of 9.4 Tesla (9.4T) FTICR-MS data. This folder contains the processed data and three subfolders, one containing the .xml files, one containing the water CoreMS output files, and the other containing instructions and scripts for processing the files in CoreMS (https://github.com/EMSL-Computing/CoreMS). All files are .csv, .pdf, .R, .xml, .d, .html, .Rmd, .py, .cal, .json, .jpg, .jpeg, .png, .mov, or .mp4.

Anions↗

On the importance of color in mass spectrometry imaging

Mass spectrometry imaging (MSI) data visualization relies on heatmaps to show the spatial distribution and measured abundances of molecules within a sample. Non-uniform color gradients such as jet are still commonly used to visualize MSI data, increasing the probability of data misinterpretation and false conclusions. Also, the use of non-uniform color gradients and the combination of hues used in common colormaps makes it challenging for people with color vision deficiencies (CVDs) to visualize and accurately interpret data. Here we present best practices for choosing a colormap to accurately display MSI data, improve readability, and accommodate all CVDs. We also provide other resources on the misuse of color in the scientific field and resources on scientifically derived colormaps presented herein.

47 OTHER INSTRUMENTATION↗