Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “spectral”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

An Algorithm to Derive Temperature and Humidity Profile Changes Using Spatially and Temporally Averaged Spectral Radiance Differences

A linear inversion algorithm to derive changes of surface skin temperature and atmospheric temperature and specific humidity vertical profiles using spatially and temporally averaged spectral radiance differences is developed. The algorithm uses spectral radiative kernels, which is the top-of-atmosphere spectral radiance change caused by perturbations of skin temperature and air temperature and specific humidity in the atmosphere, and is an improved version of the algorithm used in earlier studies. Two improvements are the inclusion of the residual and cloud spectral kernels in the form of eigenvectors of principal components. Three and six eigenvectors are used for, respectively, the residual and cloud spectral kernels. An underlying assumption is that the spectral shape of the principal components is constant and their magnitude varies temporally and spatially. The algorithm is tested using synthetic spectral radiances with the spectral range of the Atmospheric Infrared Sounder averaged over 16 days and over a 10° × 10° grid box. Changes of skin temperature, air temperature, and specific humidity vertical profiles are derived from the difference of nadir-view all-sky spectral radiances. The root-mean-square difference of retrieved and true skin temperature differences is 0.59 K. The median of absolute errors in the air temperature change is less than 0.5 K above 925 hPa. The median of absolute errors in the relative specific humidity changes is less than 10% above 825 hPa.

Fang Pan↗

An Initial Assessment of the Impact of System Spectral Response Parameters on Driving Ocean Color Applications for the GeoXO Ocean Color Instrument (OCX)

NOAA’s Geostationary Extended Observations (GeoXO) program is planning to include a hyperspectral ocean color instrument (OCX) in geostationary orbit slated for operations by the early 2030s. Shared international focus has led to a diverse legacy of space-based remote sensing ocean color missions that have and will continue to provide ocean color products into the future at a variety of spatial, temporal, and spectral resolutions. This work reports on an investigation of the impacts of system spectral response parameters on spectral shape and algal bloom detection for the planned OCX instrument. A dataset of high resolution (1 nm spectral sampling) in-situ spectra of red tide collected with an above water spectrometer, and associated K. brevis cell concentrations, were used to simulate OCX observations of varying system spectral response parameters. The OCX Performance Operational Requirements Document (PORD) level spectral resolution and sampling are varied concurrently and the location of band centers is varied independently. The impacts to the spectral shape using hyperspectral signature analysis, as well as the impacts to two heritage multispectral algal bloom detection algorithms – red band difference (RBD) and Karenia brevis bloom index (KBBI) – are assessed considering both changes in resolution/sampling and band center location. This work provides a quantitative assessment of the impacts of system spectral response requirements on both the spectral shape of observations as well as the algal bloom detection to provide insight on how various instrument performance parameters influence science and operational utility of OCX. Future work will seek to expand this analysis to include a larger dataset that considers additional water cases.

Monica Cook↗

An Initial Assessment of the Impact of System Spectral Response Parameters on Driving Ocean Color Applications for the GeoXO Ocean Color Instrument (OCX)

NOAA’s Geostationary Extended Observations (GeoXO) program is planning to include a hyperspectral ocean color instrument (OCX) in geostationary orbit slated for operations by the early 2030s. Shared international focus has led to a diverse legacy of space-based remote sensing ocean color missions that have and will continue to provide ocean color products into the future at a variety of spatial, temporal, and spectral resolutions. This work reports on an investigation of the impacts of system spectral response parameters on spectral shape and algal bloom detection for the planned OCX instrument. A dataset of high resolution (1 nm spectral sampling) in-situ spectra of red tide collected with an above water spectrometer, and associated K. brevis cell concentrations, were used to simulate OCX observations of varying system spectral response parameters. The OCX Performance Operational Requirements Document (PORD) level spectral resolution and sampling are varied concurrently and the location of band centers is varied independently. The impacts to the spectral shape using hyperspectral signature analysis, as well as the impacts to two heritage multispectral algal bloom detection algorithms – red band difference (RBD) and Karenia brevis bloom index (KBBI) – are assessed considering both changes in resolution/sampling and band center location. This work provides a quantitative assessment of the impacts of system spectral response requirements on both the spectral shape of observations as well as the algal bloom detection to provide insight on how various instrument performance parameters influence science and operational utility of OCX. Future work will seek to expand this analysis to include a larger dataset that considers additional water cases.

M. Cook↗

Leveraging ­ CPF Spectral Information for Effective Angular Corrections in Sensor Inter-calibration Studies

The Climate Absolute Radiance and Refractivity Observatory Pathfinder (CPF) mission will provide a high-accuracy (0.3% radiometric uncertainty at k=1) SI-traceable on-orbit calibration reference for sensor intercalibration in reflective solar spectral region. CPF inter-calibration algorithms have been developed to address various sampling differences between CPF and target sensors, particularly in spectral, angular, spatial and temporal domains. CPF provides unique hyper-spectral measurements that allow the utilization of rich spectral information for critical inter-calibration procedures including angular correction and spectral-gap filling. The angular correction scheme of CPF mission has been constructed based on the spectral correlation relationship between CPF observed spectra and the spectra to be measured at the viewing/sun geometry angles of target sensors. The angular correction relationship is both angular and scene dependent. The scene variability issue can impose undesired uncertainties that complicates the correction for those errors. We have demonstrated that hyper-spectral radiance information can be well utilized to identify different scene types associated with CPF observations. Using spectral radiances-based scene clustering analysis can greatly reduce the uncertainty associated with the angular correction algorithm. Additionally, a reliable quality control scheme has been established, utilizing spectral similarity and regression-prediction error analyses, to ensure the successful and efficient implementation of the angular correction method.

Wan Wu↗

Training and Validation of Spectral Gap Filling Algorithm for Cpf-Ceres Intercalibration

The Climate Absolute Radiance and Refractivity Observatory (CLARREO) Pathfinder (CPF) mission is set to launch an SI-traceable reflective solar (RS) spectrometer aboard the International Space Station to measure Earth-reflected solar radiation with a radiometric uncertainty of 0.3% (k=1). The CPF intercalibration team has devised a cutting-edge methodology to accurately transfer the benchmark CPF calibration reference to the shortwave (SW) channel (200-5000 nm) of the Clouds and the Earth’s Radiant Energy System (CERES) instrument. The spectral range of CPF measurements spans from 350-2300 nm, while the CERES SW channel measures the Earth-reflected broadband solar radiances between 200 nm to 5 μm. To conduct precise CPF-CERES intercalibration analysis, the CPF-like spectral radiances outside the CPF spectral range need to be estimated to match the CERES SW spectral range. In response, the team has developed a fast algorithm that leverages spectrally redundant information within the CPF-measured portion through principal component analysis (PCA) and utilizes pre-established spectral correlation relationships among wavelengths to extend the CPF spectrum below 350 nm and above 2300 nm. Our results show that the algorithm achieves excellent accuracy in generating the missing energy in the UV and IR portions. The RMS error in the UV region is less than 4.5x10-3 W/m2/sr/nm, while in the IR region, it is smaller than 8x10-5 W/m2/sr/nm. Our methodology was validated using measured EMIT radiance data, which covers the spectral range from 0.381 μm to 2.493 μm. We employed EMIT radiances within the wavelength range of 0.43 – 2.25 μm to generate radiances for both the shorter wavelength range (0.381 – 0.43 μm) and longer wavelength range (2.25 – 2.493 μm). The generated radiances agree very well with the measured EMIT radiances. The standard deviation in the integrated broadband radiances was about 0.1%, and the bias is less than 0.004% for over 1.5 million EMIT measured samples. These statistics show that the spectral gap filling algorithm is robust and effective in substantially reducing the spectral difference-induced uncertainty in the CPF-CERES intercalibration samples.

Qiguang Yang↗

Reflectance determination of optical spectral emissivity of metal surfaces at ambient conditions

Optical pyrometry requires knowledge of both spectral radiance and spectral emissivity to accurately measure temperature. No reliable compendium of spectral emissivity data currently exists for common metals in the optical and near-infrared spectral regions where pyrometry is typically performed. In this paper, we measure the spectral reflectivity of numerous common metals, with known surface finishes, between 400 and 1100 nm. The measurements are carried out under ambient conditions, near 300 K at an atmospheric pressure of ~0.78 bar. We then calculate the emissivity as a function of the wavelength for each sample. We define and use the illumination and collection geometries most practical for applying these measurements to radiometric thermometry. We also examine the effect of surface finish upon the relative spectral emissivity of a given material and find qualitative guidelines for predicting the increase in emissivity with increasing surface roughness. Finally, these measurements can both improve the accuracy and precision of optical pyrometry and provide the necessary reference value for converting emerging diagnostic measurements of relative spectral emissivity under extreme dynamic conditions into absolute dynamic spectral emissivity.

36 MATERIALS SCIENCE↗

All the light we cannot see: Climate manipulations leave short and long‐term imprints in spectral reflectance of trees

Abstract Anthropogenic climate change, particularly changes in temperature and precipitation, affects plants in multiple ways. Because plants respond dynamically to stress and acclimate to changes in growing conditions, diagnosing quantitative plant‐environment relationships is a major challenge. One approach to this problem is to quantify leaf responses using spectral reflectance, which provides rapid, inexpensive, and nondestructive measurements that capture a wealth of information about genotype as well as phenotypic responses to the environment. However, it is unclear how warming and drought affect spectra. To address this gap, we used an open‐air field experiment that manipulates temperature and rainfall in 36 plots at two sites in the boreal‐temperate ecotone of northern Minnesota, USA. We collected leaf spectral reflectance (400–2400 nm) at the peak of the growing season for three consecutive years on juveniles (two to six years old) of five tree species planted within the experiment. We hypothesized that these mid‐season measurements of spectral reflectance capture a snapshot of the leaf phenotype encompassing a suite of physiological, structural, and biochemical responses to both long‐ and short‐time scale environmental conditions. We show that the imprint of environmental conditions experienced by plants hours to weeks before spectral measurements is linked to regions in the spectrum associated with stress, namely the water absorption regions of the near‐infrared and short‐wave infrared. In contrast, the environmental conditions plants experience during leaf development leave lasting imprints on the spectral profiles of leaves, attributable to leaf structure and chemistry (e.g., pigment content and associated ratios). Our analyses show that after accounting for baseline species spectral differences, spectral responses to the environment do not differ among the species. This suggests that building a general framework for understanding forest responses to climate change through spectral metrics may be possible, likely having broader implications if the common responses among species detected here represent a widespread phenomenon. Consequently, these results demonstrate that examining the entire spectrum of leaf reflectance for environmental imprints in contrast to single features (e.g., indices and traits) improves inferences about plant‐environment relationships, which is particularly important in times of unprecedented climate change.

Stefanski, Artur [Department of Forest Resources U↗

Partial spectral flow in the D1D5 CFT

The two-dimensional 𝒩 = 4 superconformal algebra has a free field realization with four bosons and four fermions. There is an automorphism of the algebra called spectral flow. Under spectral flow, the four fermions are transformed together. In this paper, we study partial spectral flow where only two of the four fermions are transformed. Partial spectral flow is applied to the D1D5 CFT where a marginal deformation moves the CFT away from the free point. The partial spectral flow is broken by the deformation. We show that this effect can be studied due to a transformation of the deformation which is well-defined under partial spectral flow. As a result in the spectrum, we demonstrate how to compute the second-order energy lift of a D1D5P state through its partial spectral flowed state. We find that D1D5P states related by partial spectral flow do not have the same lift in general.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Axial H-Bonding Solvent Controls Inhomogeneous Spectral Broadening, While Peripheral H-Bonding Solvent Controls Vibronic Broadening: Cresyl Violet in Methanol

The dynamics of the nuclei of both a chromophore and its condensed-phase environment control many spectral features, including the vibronic and inhomogeneous broadening present in spectral line shapes. For the cresyl violet chromophore in methanol, we here analyze and isolate the effect of specific chromophore–solvent interactions on simulated spectral densities, reorganization energies, and linear absorption spectra. Employing both chromophore and its condensed-phase environment control many spectral features, including the vibronic and inhomogeneous broadening present in spectral line shapes. For the cresyl violet chromophore in methanol, we here analyze and isolate the effect of specific chromophore–solvent interactions on simulated spectral densities, reorganization energies, and linear absorption spectra. Employing both force field and ab initio molecular dynamics trajectories along with the inclusion of only certain solvent molecules in the excited-state calculations, we determine that the methanol molecules axial to the chromophore are responsible for the majority of inhomogeneous broadening, with a single methanol molecule that forms an axial hydrogen bond dominating the response. Furthermore, the strong peripheral hydrogen bonds do not contribute to spectral broadening, as they are very stable throughout the dynamics and do not lead to increased energy-gap fluctuations. We also find that treating the strong peripheral hydrogen bonds as molecular mechanical point charges during the molecular dynamics simulation underestimates the vibronic coupling. Including these peripheral hydrogen bonding methanol molecules in the quantum-mechanical region in a geometry optimization increases the vibronic coupling, suggesting that a more advanced treatment of these strongly interacting solvent molecules during the molecular dynamics trajectory may be necessary to capture the full vibronic spectral broadening.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

On the equivalence of some spectral sequences for Serre fibrations

Several different constructions of a spectral sequence for a Serre fibration {pi}:E{yields}B over a compact simply connected manifold B are considered in this paper. Namely, we consider the spectral sequence for the minimal model ({Lambda}Vx{Lambda}W,d) of the fibration, along with the spectral sequences arising from the Cech filtration in the complexes C*(U,A*{sub PL}({pi}{sup -1}(U))) and C*(U,S*({pi}{sup -1}(U))), where U=(U) is a covering of the base B. It is known that all these spectral sequences have the same terms E{sub 2}*{sup ,}*=H*(X)xH{sup *}(F) and converge to the cohomology of the total space E. A new natural isomorphism of these spectral sequences is constructed in every term E{sub r} with r{>=}2. It is also proved that in the case of a smooth locally trivial fibration these spectral sequences are isomorphic to the spectral sequences of the complex of smooth forms {Omega}*(E) and of the Cech-de Rham complex. It is therefore established that all these constructions give the same spectral sequence, starting from the E{sub 2} term. Bibliography: 9 titles.

97 MATHEMATICS AND COMPUTING↗

Probing plasma physics with spectral index maps of accreting black holes on event horizon scales

The Event Horizon Telescope (EHT) collaboration has produced the first resolved images of the supermassive black holes at the centre of our galaxy and at the centre of the elliptical galaxy M87. As both technology and analysis pipelines improve, it will soon become possible to produce spectral index maps of black hole accretion flows on event horizon scales. Here, in this work, we predict spectral index maps of both M87* and Sgr A* by applying the general relativistic radiative transfer (GRRT) code IPOLE to a suite of general relativistic magnetohydrodynamic (GRMHD) simulations. We analytically show that the spectral index increases with increasing magnetic field strength, electron temperature, and optical depth. Consequently, spectral index maps grow more negative with increasing radius in almost all models, since all of these quantities tend to be maximized near the event horizon. Additionally, photon ring geodesics exhibit more positive spectral indices, since they sample the innermost regions of the accretion flow with the most extreme plasma conditions. Spectral index maps are sensitive to highly uncertain plasma heating prescriptions (the electron temperature and distribution function). However, if our understanding of these aspects of plasma physics can be tightened, even the spatially unresolved spectral index around 230 GHz can be used to discriminate between models. In particular, Standard and Normal Evolution (SANE) flows tend to exhibit more negative spectral indices than Magnetically Arrested Disc (MAD) flows due to differences in the characteristic magnetic field strength and temperature of emitting plasma.

(magnetohydrodynamics) MHD↗

Spectral phase shifts in femtosecond parametric down-conversion with media dispersion

We theoretically study the spectral phase shift of a midinfrared (MIR) femtosecond pulse generated through parametric frequency down-conversion in dispersive media, with an emphasis on the effect of group-velocity dispersion (GVD), with the aim of obtaining guidelines for dispersion compensation and pulse compression in such systems. It is found that the spectral phase of the generated MIR pulse differs significantly from that of due to its linear propagation. We consider two common ways of MIR femtosecond pulse generation: difference frequency generation (DFG) and optical parametric amplification (OPA). The resultant spectral phase is determined by the initial injection condition, and the transfer of the spectral phase accumulated by the higher-frequency fields. Our results show that in DFG, pump depletion has little effect on the spectral phase, while in OPA, the combined effect of linear GVD and high parametric gain leads to a notable dependence of spectral phase on gain--the higher the gain, the less the spectral phase. Quantitatively, under conditions where the MIR pulse is generated through injection of two higher-frequency fields, its spectral phase is close to only half of that accumulated through linear propagation in DFG, while it is even smaller in OPA. To obtain the shortest MIR femtosecond pulse, these results determine the amount of dispersion that needs compensation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Spectral indices measurements using miniature fission chambers at the MINERVE zero-power reactor at CEA using calibration data obtained at the BR1 reactor at SCK.CEN

Spectral indices are parameters of major importance to characterize a multiplying medium and to evaluate performances of neutronics calculation tools as well as quality of associated nuclear data. Experiments performed in 2004 at the CEA MINERVE facility loaded with the R1-UO{sub 2} lattice [1], using homemade miniature fission chambers and calibration data acquired at the SCK.CEN BR1 facility in 2001 [2], resulted in ambivalent conclusions. On one hand, spectral indices involving only fissile isotopes gave relevant results and consistent discrepancies between calculation and experiment. On the other hand, spectral indices involving both fissile and fertile isotopes showed inconsistent results depending on the type of calibration data used. In particular, the {sup 238}U(n,f)/{sup 235}U(n,f) spectral indices resulted in values far from the calculations in all cases. In 2004, those differences between measurement and calculation were mainly attributed to an imprecise knowledge of the isotopic composition of the deposits loaded in the {sup 238}U chambers. At that time, priorities in the development of programs in MINERVE and other considerations about the manufacturing and calibration of new fission chambers did not allow to further investigate these discrepancies. In 2009, the preparation of a new program at the EOLE facility [1] and changes in the regulatory framework for management of fission chambers motivated the manufacturing of new detectors. At the same time, the re-installation of the R1-UO{sub 2} lattice in MINERVE gave the opportunity to carry out a new spectral indices measurement campaign. Nevertheless, although the isotopic composition of active deposits was better known than previously, the comparison between experimental results and calculations still resulted in inconsistent discrepancies. A sensitivity study indicated afterwards that, among all parameters to be considered for the analysis and the assessment of final uncertainty, calibration data have the greatest impact. In April 2010, a new calibration campaign conducted again at the BR1 facility allowed the CEA to reanalyze the spectral indices measurements performed in 2009. With this new set of calibration data, the experimental values of spectral indices finally matched the calculation results within the uncertainty margins. In addition, the confrontation of data from 2001 and 2010 calibration campaigns, both performed with the same experimental conditions, allowed to shed on the light dead time correction issues in the monitoring of calibration measurements. At the end, this also explained the inconsistencies observed during the 2004 campaign. This paper first, presents the two different analysis methods for getting the experimental value of a spectral index and, lists main parameters that influence the determination of the experimental value. It then details the calibration processes that are set-up at the MINERVE and BR1 facilities, describes the various experiments carried out and finally comments the results obtained. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Spectral Effects in Albedo and Rearside Irradiance Measurement for Bifacial Performance Estimation

We investigate the impact of spectral dependence of ground surface reflectivity on albedo and rearside irradiance measurements necessary for bifacial photovoltaic (PV) module performance estimation and monitoring. Because PV modules are spectrally selective, albedo and irradiance measurements performed with common irradiance sensors may require spectral mismatch corrections when used for performance prediction. We investigate via simulation the differences in spectrally responsive albedo measured with thermopile pyranometers and crystalline silicon PV reference cells in comparison to a typical crystalline-silicon bifacial PV module. Simulations are performed for nine different representative ground surface materials using simulated solar spectra together with spectral reflectivity data distributed with the SMARTS simulation software. For the materials considered, the results show that albedo spectral mismatch relative to the bifacial module is distributed over a range of ±9.2% for thermopile pyranometers versus only ±3.7% for a typical PV reference cell. We consider the impact of this spectrally-responsive albedo mismatch on bifacial PV module rearside irradiance measurements. Using synthesized rearside spectral irradiance distributions, we find that for the nine different ground surface materials the predicted rearside irradiance measurement deviates from the effective irradiance observed by the PV module by on the order of 16.5 W/m 2 for the pyranometer and 3.6 W/m 2 for the PV reference cell. We discuss the implications for bifacial albedo and irradiance measurement.

41 EE - Solar Energy Technologies Office (EE-4S)↗

3D high spectral and spatial resolution imaging of ex vivo mouse brain

Purpose: Widely used MRI methods show brain morphology both in vivo and ex vivo at very high resolution. Many of these methods (e.g., T{sub 2}{sup *}-weighted imaging, phase-sensitive imaging, or susceptibility-weighted imaging) are sensitive to local magnetic susceptibility gradients produced by subtle variations in tissue composition. However, the spectral resolution of commonly used methods is limited to maintain reasonable run-time combined with very high spatial resolution. Here, the authors report on data acquisition at increased spectral resolution, with 3-dimensional high spectral and spatial resolution MRI, in order to analyze subtle variations in water proton resonance frequency and lineshape that reflect local anatomy. The resulting information compliments previous studies based on T{sub 2}{sup *} and resonance frequency. Methods: The proton free induction decay was sampled at high resolution and Fourier transformed to produce a high-resolution water spectrum for each image voxel in a 3D volume. Data were acquired using a multigradient echo pulse sequence (i.e., echo-planar spectroscopic imaging) with a spatial resolution of 50 × 50 × 70 μm{sup 3} and spectral resolution of 3.5 Hz. Data were analyzed in the spectral domain, and images were produced from the various Fourier components of the water resonance. This allowed precise measurement of local variations in water resonance frequency and lineshape, at the expense of significantly increased run time (16–24 h). Results: High contrast T{sub 2}{sup *}-weighted images were produced from the peak of the water resonance (peak height image), revealing a high degree of anatomical detail, specifically in the hippocampus and cerebellum. In images produced from Fourier components of the water resonance at −7.0 Hz from the peak, the contrast between deep white matter tracts and the surrounding tissue is the reverse of the contrast in water peak height images. This indicates the presence of a shoulder in the water resonance that is not present at +7.0 Hz and may be specific to white matter anatomy. Moreover, a frequency shift of 6.76 ± 0.55 Hz was measured between the molecular and granular layers of the cerebellum. This shift is demonstrated in corresponding spectra; water peaks from voxels in the molecular and granular layers are consistently 2 bins apart (7.0 Hz, as dictated by the spectral resolution) from one another. Conclusions: High spectral and spatial resolution MR imaging has the potential to accurately measure the changes in the water resonance in small voxels. This information can guide optimization and interpretation of more commonly used, more rapid imaging methods that depend on image contrast produced by local susceptibility gradients. In addition, with improved sampling methods, high spectral and spatial resolution data could be acquired in reasonable run times, and used for in vivo scans to increase sensitivity to variations in local susceptibility.

60 APPLIED LIFE SCIENCES↗

ON THE LATE-TIME SPECTRAL SOFTENING FOUND IN X-RAY AFTERGLOWS OF GAMMA-RAY BURSTS

Strong spectral softening has been revealed in the late X-ray afterglows of some gamma-ray bursts (GRBs). The scenario of X-ray scattering around the circumburst dusty medium has been supported by previous works due to its overall successful prediction of both the temporal and spectral evolution of some X-ray afterglows. To further investigate the observed feature of spectral softening we now systematically search the X-ray afterglows detected by the X-ray telescope aboard Swift and collect 12 GRBs with significant late-time spectral softening. We find that dust scattering could be the dominant radiative mechanism for these X-ray afterglows regarding their temporal and spectral features. For some well-observed bursts with high-quality data, the time-resolved spectra could be well-produced within the scattering scenario by taking into account the X-ray absorption from the circumburst medium. We also find that during spectral softening the power-law index in the high-energy end of the spectra does not vary much. The spectral softening is mainly manifested by the spectral peak energy continually moving to the soft end.

79 ASTRONOMY AND ASTROPHYSICS↗

Time-resolved High Spectral Resolution Observation of 2MASSW J0746425+200032AB

Many brown dwarfs (BDs) exhibit photometric variability at levels from tenths to tens of percents. The photometric variability is related to magnetic activity or patchy cloud coverage, characteristic of BDs near the L–T transition. Time-resolved spectral monitoring of BDs provides diagnostics of cloud distribution and condensate properties. However, current time-resolved spectral studies of BDs are limited to low spectral resolution ( R ∼ 100) with the exception of the study of Luhman 16 AB at a resolution of 100,000 using the VLT+CRIRES. This work yielded the first map of BD surface inhomogeneity, highlighting the importance and unique contribution of high spectral resolution observations. Here, we report on the time-resolved high spectral resolution observations of a nearby BD binary, 2MASSW J0746425+200032AB. We find no coherent spectral variability that is modulated with rotation. Based on simulations, we conclude that the coverage of a single spot on 2MASSW J0746425+200032AB is smaller than 1% or 6.25% if spot contrast is 50% or 80% of its surrounding flux, respectively. Future high spectral resolution observations aided by adaptive optics systems can put tighter constraints on the spectral variability of 2MASSW J0746425+200032AB and other nearby BDs.

79 ASTRONOMY AND ASTROPHYSICS↗

Estimation of spectral reflectance curves from multispectral image data

A technique is presented for estimating spectral reflectance curves from multispectral image data even if the spectral samples are obtained from channels whose spectral responsivity is not narrowband. It is demonstrated that these reflectance estimates can be written as a linear combination of the spectral samples and that, analogous to Shannon's sampling theorem, if the spectral reflectance is a natural cubic spline, it can be estimated exactly provided the number of spectral channels is sufficiently large. Simulation results suggest that the accuracy of the spectral reflectance estimates is quite good and very insensitive to the spectral responsivity shapes.

Park, S. K.↗