Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “source configuration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Turbulent Transport in a Three-dimensional Solar Wind

Turbulence in the solar wind can play essential roles in the heating of coronal and solar wind plasma and the acceleration of the solar wind and energetic particles. Turbulence sources are not well understood and thought to be partly enhanced by interaction with the large-scale inhomogeneity of the solar wind and the interplanetary magnetic field and/or transported from the solar corona. To investigate the interaction with background inhomogeneity and the turbulence sources, we have developed a new 3D MHD model that includes the transport and dissipation of turbulence using the theoretical model of Zank et al. We solve for the temporal and spatial evolution of three moments or variables, the energy in the forward and backward fluctuating modes and the residual energy and their three corresponding correlation lengths. The transport model is coupled to our 3D model of the inhomogeneous solar wind. We present results of the coupled solar wind-turbulence model assuming a simple tilted dipole magnetic configuration that mimics solar minimum conditions, together with several comparative intermediate cases. By considering eight possible solar wind and turbulence source configurations, we show that the large-scale solar wind and IMF inhomogeneity and the strength of the turbulence sources significantly affect the distribution of turbulence in the heliosphere within 6 au. We compare the predicted turbulence distribution results from a complete solar minimum model with in situ measurements made by the Helios and Ulysses spacecraft, finding that the synthetic profiles of the turbulence intensities show reasonable agreement with observations.

79 ASTRONOMY AND ASTROPHYSICS↗

System and method for portable multi-band black body simulator

The present disclosure relates to an apparatus for simulating a black body spectrum. The apparatus makes use of a broadband light source and a light guide configured to receive light generated by the light source and to generate first and second optical signals. A first signal processing subsystem may be used to enable adjustment of both a signal spectrum and an intensity of the first optical signal. A second signal processing subsystem may be used to enable adjustment of both a signal spectrum and an intensity of the second optical signal. A beam cube may be used to combine the first and second optical signals to produce a final light output signal having a desired signal spectrum and a desired intensity.

42 ENGINEERING↗

Integrated development facility for the calibration of low-energy charged particle flight instrumentation

The design of a low-energy ion facility for development and calibration of thermal ion instrumentation is examined. A directly heated cathode provides the electrons used to produce ions by impact ionization and an applied magnetic field increases the path length followed by the electrons. The electrostatic and variable geometry magnetic mirror configuration in the ion source is studied. The procedures for the charge neutralization of the beam and the configuration and function of the 1.4-m drift tube are analyzed. A microcomputer is utilized to control and monitor the beam energy and composition, and the mass- and angle-dependent response of the instrument under testing. The facility produces a high-quality ion beam with an adjustable range of energies up to 150 eV; the angular divergence and uniformity of the beam is obtained from two independent retarding potential analyzers. The procedures for calibrating the instrument being developed are described.

Biddle, A. P.↗

Description of the code ANVIL (ANisotropic Vhf Impulse Location)

In this paper, we have developed a general, three-dimensional method to locate sources of earth-directed radiation which takes into account the flight paths of reflected signals. While time-of-arrival algorithms exist for locating radio sources using line-of-sight propagation paths, radio sources originating above the surface of the earth will not necessarily emit strong power along direct paths to satellites. A combination of direct and ground-reflected pulses or only ground-reflected signals from such sources could be received by satellite-borne sensors. The work presented here applies to satellite detection of sub-ionospheric radio sources in a vacuum environment with ideal reflection off the earth's surface. Because satellites are not static receivers, their configuration with respect to a radio source is not always optimal. Therefore, a statistical study is performed using 1000 randomized configurations of 24 satellites in middle earth orbit. For each configuration, the radio source latitude and longitude is fixed, and its altitude is varied from 1 to 97 km. An analytic direct-path algorithm using the five satellites nearest the radio source provides an initial guess for the radio source latitude and longitude. We find that, using this approximation, the mean error in the calculated nadir location has a maximum value of 134 m for the 97-km source altitude. The coordinates of the initial guess are used to define the origin of a grid within which an all-points search refinement is performed. Finally, using this procedure, the overall maximum mean error in radio source position is found to be on the order of the computational grid size.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Special Component Designs for Differential-Amplifier MMICs

Special designs of two types of electronic components transistors and transmission lines have been conceived to optimize the performances of these components as parts of waveguide-embedded differential-amplifier monolithic microwave integrated circuits (MMICs) of the type described in the immediately preceding article. These designs address the following two issues, the combination of which is unique to these particular MMICs: Each MMIC includes a differential double-strip transmission line that typically has an impedance between 60 and 100 W. However, for purposes of matching of impedances, transmission lines having lower impedances are also needed. The transistors in each MMIC are, more specifically, one or more pair(s) of InP-based high-electron-mobility transistors (HEMTs). Heretofore, it has been common practice to fabricate each such pair as a single device configured in the side-to-side electrode sequence source/gate/drain/gate/source. This configuration enables low-inductance source grounding from the sides of the device. However, this configuration is not suitable for differential operation, in which it is necessary to drive the gates differentially and to feed the output from the drain electrodes differentially. The special transmission-line design provides for three conductors, instead of two, in places where lower impedance is needed. The third conductor is a metal strip placed underneath the differential double-strip transmission line. The third conductor increases the capacitance per unit length of the transmission line by such an amount as to reduce the impedance to between 5 and 15 W. In the special HEMT-pair design, the side-to-side electrode sequence is changed to drain/gate/source/gate/ drain. In addition, the size of the source is reduced significantly, relative to corresponding sizes in prior designs. This reduction is justified by the fact that, by virtue of the differential configuration, the device has an internal virtual ground, and therefore there is no need for a low-resistance contact between the source and the radio-frequency circuitry. The source contact is needed only for DC biasing. These designs were implemented in a single-stage-amplifier MMIC. In a test at a frequency of 305 GHz, the amplifier embedded in a waveguide exhibited a gain of 0 dB; after correcting for the loss in the waveguide, the amplifier was found to afford a gain of 0.9 dB. In a test at 220 GHz, the overall gain of the amplifier- and-waveguide assembly was found to be 3.5 dB.

Kangaslahti, Pekka↗

Magnetic Topology of Coronal Hole Linkages

In recent work, Antiochos and coworkers argued that the boundary between the open and closed field regions on the Sun can be extremely complex with narrow corridors of open ux connecting seemingly disconnected coronal holes from the main polar holes, and that these corridors may be the sources of the slow solar wind. We examine, in detail, the topology of such magnetic configurations using an analytical source surface model that allows for analysis of the eld with arbitrary resolution. Our analysis reveals three important new results: First, a coronal hole boundary can join stably to the separatrix boundary of a parasitic polarity region. Second, a single parasitic polarity region can produce multiple null points in the corona and, more important, separator lines connecting these points. Such topologies are extremely favorable for magnetic reconnection, because it can now occur over the entire length of the separators rather than being con ned to a small region around the nulls. Finally, the coronal holes are not connected by an open- eld corridor of finite width, but instead are linked by a singular line that coincides with the separatrix footprint of the parasitic polarity. We investigate how the topological features described above evolve in response to motion of the parasitic polarity region. The implications of our results for the sources of the slow solar wind and for coronal and heliospheric observations are discussed.

Titov, V. S.↗

Two-chamber configuration of Bio-Nano electron cyclotron resonance ion source for fullerene modification

We report on the modification of fullerenes with iron and chlorine using two individually controllable plasmas in the Bio-Nano electron cyclotron resonance ion source (ECRIS). One of the plasmas is composed of fullerene and the other one is composed of iron and chlorine. The online ion beam analysis allows one to investigate the rate of the vapor-phase collisional modification process in the ECRIS, while the offline analyses (e.g., liquid chromatography-mass spectrometry) of the materials deposited on the plasma chamber can give information on the surface-type process. Both analytical methods show the presence of modified fullerenes such as fullerene-chlorine, fullerene-iron, and fullerene-chlorine-iron.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Carbonate clumped isotope analysis (Δ 47 ) of 21 carbonate standards determined via gas‐source isotope‐ratio mass spectrometry on four instrumental configurations using carbonate‐based standardization and multiyear data sets

Rationale Clumped isotope geochemistry examines the pairing or clumping of heavy isotopes in molecules and provides information about the thermodynamic and kinetic controls on their formation. The first clumped isotope measurements of carbonate minerals were first published 15 years ago, and since then, interlaboratory offsets have been observed, and laboratory and community practices for measurement, data analysis, and instrumentation have evolved. Here we briefly review historical and recent developments for measurements, share Tripati Lab practices for four different instrument configurations, test a recently published proposal for carbonate‐based standardization on multiple instruments using multi‐year data sets, and report values for 21 different carbonate standards that allow for recalculations of previously published data sets. Methods We examine data from 4628 standard measurements on Thermo MAT 253 and Nu Perspective IS mass spectrometers, using a common acid bath (90°C) and small‐sample (70°C) individual reaction vessels. Each configuration was investigated by treating some standards as anchors (working standards) and the remainder as unknowns (consistency standards). Results We show that different acid digestion systems and mass spectrometer models yield indistinguishable results when instrument drift is well characterized. For linearity correction, mixed gas‐and‐carbonate standardization or carbonate‐only standardization yields similar results. No difference is observed in the use of three or eight working standards for the construction of transfer functions. Conclusions We show that all configurations yield similar results if instrument drift is robustly characterized and validate a recent proposal for carbonate‐based standardization using large multiyear data sets. Δ 47 values are reported for 21 carbonate standards on both the absolute reference frame (ARF; also refered to as the Carbon Dioxide Equilibrated Scale or CDES) and the new InterCarb‐Carbon Dioxide Equilibrium Scale (I‐CDES) reference frame, facilitating intercomparison of data from a diversity of labs and instrument configurations and restandardization of a broad range of sample sets between 2006, when the first carbonate measurements were published, and the present.

58 GEOSCIENCES↗

Machine learning model explanation apparatus and methods

Explanation apparatus and methods are described. In one aspect, an explanation apparatus includes processing circuity configured to access a source instance which has been classified by a machine learning model; create associations of the source instance with a plurality of training instances; and process the associations of the source instance and the training instances to identify a first subset of the training instances which have less relevance to the classification decision of the source instance by the machine learning model compared with a second subset of the training instances; and an interface configured to communicate information to a user, and wherein the processing circuitry is configured to control the user interface to communicate the second subset of the training instances to the user as evidence to explain the classification of the source instance by the machine learning model.

Arendt, Dustin↗

w22_laser-radiography: Laser-Based MeV Radiography [Slides]

X-ray sources based on high-power short pulse lasers have unique advantages over conventional sources, like small spot size, flexible configuration, and tailorable spectra. Development of these sources will allow LANL to fulfill an urgent need to deploy flexible, compact, x-ray sources for static and dynamic radiography at our firing sites and facilities such as pRad and U1a. Our IC allocation supports the development of a predictive modeling capability of these laser-based sources.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

XPlacer/Tracer

XPlacer/Tracer is a dynamic analysis tool that finds bad memory access patterns in heterogeneous codes. XPlacer/Tracer consists of two components. (1) A configurable ROSE plugin for source code instrumentation of heterogeneous code written in the C/C++ and CUDA programming languages. (2) A sample configuration that instruments memory accesses to dynamic memory in CPU and GPU codes, and a runtime library that tracks these memory accesses at runtime. The collected information is reported in form of a textual summary or as memory map that can be converted to images.

Pirkelbauer, PeterM.↗

Output of acoustical sources

Acoustic radiation from a source, here viewed as an immobile point singularity with periodic strength and a given multipolar nature, is affected by the presence of nearly structural elements (e.g., rigid or impedance surfaces) as well as that of a background flow in the medium. An alternative to the conventional manner of calculating the net source output by integrating the energy flux over a distant control surface is described; this involves a direct evaluation of the secondary wavefunction at the position of the primary source and obviates the need for a (prospectively difficult) flux integration. Various full and half-planar surface configurations with an adjacent source are analyzed in detail, and the explicit results obtained, in particular, for the power factor of a dipole brings out a substantial rise in its output as the source nears the sharp edge of a half-plane.

Levine, H.↗

Search for TeV gamma-ray emission from point-like sources in the inner galactic plane with a partial configuration of the HAWC Observatory

A survey of the inner Galaxy region of Galactic longitude l∈[+15{sup ∘},+50{sup ∘}] and latitude b∈[−4{sup ∘},+4{sup ∘}] is performed using one-third of the High Altitude Water Cherenkov Observatory, operated during its construction phase. To address the ambiguities arising from unresolved sources in the data, we use a maximum likelihood technique to identify point source candidates. Ten sources and candidate sources are identified in this analysis. Eight of these are associated with known TeV sources but not all have differential fluxes that are compatible with previous measurements. Three sources are detected with significances >5 σ after accounting for statistical trials, and are associated with known TeV sources.

79 ASTRONOMY AND ASTROPHYSICS↗

Ion beam treatment of potential space materials at the NASA Lewis Research Center

Ion source systems in different configurations, have been used to generate unique morphologies for several NASA space applications. The discharge chamber of a 30 cm ion source was successfully used to texture potential space radiator materials for the purpose of obtaining values of thermal emittance greater than 0.85 at 700 and 900 K. High absorptance surfaces were obtained using ion beam seed texturing, for space radiator materials that were flown on the Long Duration Exposure Facility (LDEF) for 5.8 years in space. An ion source discharge chamber was also used to develop electrode surfaces with suppressed secondary electron emission characteristics for use in collectors in microwave amplifier traveling wave tubes. This was accomplished by sputtering textured carbon onto copper as well as texturing copper using tantalum and molybdenum as sacrificial texture inducing seeding materials. In a third configuration, a dual ion beam system was used to generate high transmittance diamondlike carbon (DLC) films.

Kussmaul, Michael↗

Multi-particle inspection using associated particle sources

Disclosed herein are representative embodiments of methods, apparatus, and systems for performing combined neutron and gamma ray radiography. For example, one exemplary system comprises: a neutron source; a set of alpha particle detectors configured to detect alpha particles associated with neutrons generated by the neutron source; neutron detectors positioned to detect at least some of the neutrons generated by the neutron source; a gamma ray source; a set of verification gamma ray detectors configured to detect verification gamma rays associated with gamma rays generated by the gamma ray source; a set of gamma ray detectors configured to detect gamma rays generated by the gamma ray source; and an interrogation region located between the neutron source, the gamma ray source, the neutron detectors, and the gamma ray detectors.

42 ENGINEERING↗

Core-Pedestal Plasma Configurations in Advanced Tokamaks

Here, several configurations for the core and pedestal plasma are examined for a predefined tokamak design by implementing multiple heating/current drive (H/CD) sources to achieve an optimum configuration of high fusion power in a noninductive operation while maintaining an ideally magnetohydrodynamic (MHD) stable core plasma using the IPS-FASTRAN framework. IPS-FASTRAN is a component-based lightweight coupled simulation framework that is used to simulate magnetically confined plasma by integrating a set of high-fidelity codes to construct the plasma equilibrium (EFIT, TOQ, and CHEASE), calculate the turbulent heat and particle transport fluxes (TGLF), model various H/CD systems (TORIC, TORAY, GENRAY, and NUBEAM), model the pedestal pressure and width (EPED), and estimate the ideal MHD stability (DCON). The TGLF core transport model and EPED pedestal model are used to self-consistently predict plasma profiles consistent with ideal MHD stability and H/CD (and bootstrap) current sources. In order to evaluate the achievable and sustainable plasma beta, varying configurations are produced ranging from the no-wall stability to with-wall stability regimes, simultaneously subject to the self-consistent TGLF, EPED, and H/CD source profile predictions that optimize configuration performance. The pedestal density, plasma current, and total injected power are scanned to explore their impact on the target plasma configuration, fusion power, and confinement quality. A set of fully noninductive scenarios are achieved by employing ion-cyclotron, neutral beam injection, helicon, and lower-hybrid H/CDs to provide a broad profile for the total current drive in the core region for a predefined tokamak design. These noninductive scenarios are characterized by high fusion gain (Q ~ 4) and power (P fus ~ 600 MW), optimum confinement quality (H 98 ~ 1.1), and high bootstrap current fraction (f BS ~ 0.7) for Greenwald fraction below unity. The broad current profile configurations identified are stable to low-n kink modes either because the normalized pressure β N is below the no-wall limit or a wall is present.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗