Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “soft errors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Capture Latch Assembly for the NASA Docking System

Final Paper and not the abstract is attached. a summary of the Design, Development, and Qualification of the Capture Latch Assembly (CLA) for the NASA Docking System Block 1 (NDSB1). The CLA is an integral part of the Soft Capture System (SCS) of the NDSB1, serving the purpose of connecting the mating SCS Rings of two docking vehicles. The paper will present an overview of the function of the CLA and its basic concept of operations, including a summary of the major components of the CLA. The development, qualification, and production of the CLA will then be described. Particular focus will be provided on two major issues that occurred during production and qualification of the CLA. The first issue was failures of the CLA Motor (CLM) during acceptance testing (AT). The failures of the CLM were ultimately determined to be due to design defects and manufacturing errors in the motor commutation sensor assembly. The second issue was failure of the secondary release mechanism, or Contingency Capture Latch Release (CCLR) mechanism during development and qualification testing. The CCLR failures were found to be a result of excess free play in the release mechanism, resulting in wear leading to galling inside the release mechanism. An overview of each failure will be provided, along with a summary of the failure investigation and recovery process. Finally, Lessons Learned from each of the major issues and the overall development of the Capture Latch will be presented.

Capture Latch↗

SGR 1627-41

BATSE has detected repeated soft gamma-ray bursts consistent with the same (previously unknown) location. We recorded three bursts on June 15.109, 15.296, 15.411 UT (BATSE triggers 6825, 6826, 6827, respectively) with an average duration of about 200 milliseconds. Preliminary spectral analysis of the data indicates that the events are very soft, with power law spectral indices varying between -3.0 and -7.0. BATSE triggered 5 more times, on June 17.873,17.901, 18.004, 18.035, and 18.071 UT (BATSE trigger numbers 6833, 6834, 6835, 6836 and 6837, respectively). The last trigger had a peak count rate of over 300000 counts/sec above background (integrated over 4 detectors between 20-1000 keV, in 1 second interval) and a duration of about 3 seconds. Due to Rs very high peak intensity, deadtime effects prevent us from using it for localization, until we receive more data types. The weighted location of the 7 remaining triggers is centered on R.A. = 16h27ml2.0s and dec = -41 d06.0' with an error radius of about 2 degrees. This location does not correspond to any previously known SGR source; we conclude that we have discovered a new source, SGR1627-41. We have initiated an RXTE ToO and we strongly encourage wide field observations at other wavelengths.

Kouveliotou, Chryssa↗

Discovery of soft X-ray flux from 2A 1102+384 = Markarian 421

During April 1976 a soft X-ray flux was detected with SAS 3 from the vicinity of 2A 1102+384. The average flux densities were 4.3 x 10 to the -11th and 14 x 10 to the -11th erg/sq cm per sec in the energy bands 0.1-0.28 keV and 1-6 keV, respectively. There is an indication of variability over about 0.5 day in the lowest energy band. An upper limit of 3 x 10 to the 20th H atoms per sq cm is found for the gas column density to the X-ray source. In May 1978, observations with the modulation collimators of SAS 3 yielded an accurate (40 arcsec error radius) position for the X-ray source (2-6 keV) at right ascension 11 h 1 m 39.7 s, declination + 38 deg 28 min 51 sec (equinox 1950). The earlier tentative identification by Ricketts et al. (1976) with the BL Lacertae object B2 1101+38 = Markarian 421 is thus confirmed.

Hearn, D. R.↗

Joint ROSAT-Compton GRO observations of the X-ray bright Seyfert galaxy IC 4329A

We report a simultaneous ROSAT and Gamma Ray Observatory (GRO) observation of the X-ray-bright Seyfert galaxy IC 4329A. For the GRO Oriented Scintillation Spectrometer Experiment (OSSE) detector, we also present the sum of the data for this and earlier observations. The overall spectrum is very well described as a power law with an energy spectral index of approximately 1 absorbed at low energies plus a strong Compton reflection component, typical for Seyfert 1 galaxies. The low energy absorption can be well described by a sum of a neutral column density of approximately 3 x 10(exp 21)sq cm, most of which is associated with the edge-on galactic disk of IC 4329A, plus an edgelike feature at approximately 700 eV; this feature implies either complex absorption (due to additional ionized material, or due to a partial covering), or a soft excess. The data only weakly constrain the presence of a high-energy cutoff in the underlying power law; they are compatible with an exponential cutoff at any energy E(sub c) approximately greater than 100 keV. The relative steepness of the OSSE data, with the power-law energy index of 1.6 +/- 0.2, can be accounted for entirely by the contribution of the high-energy tail of the reflection component when E(sub c) approaches infinity. (We find that the definite cutoff at an energy E(sub c)approximately 130 keV suggested in the recently published analysis of the OSSE data for this subject is due to a data reduction error.) Including nonsimultaneous Ginga observations with 2 keV fluxes matching well that of ROSAT gives us likely broad-band X-ray/gamma-ray spectra of the object from approximately 0.1 keV up to several hundred keV. We also report the ROSAT spectrum of the companion object to the Seyfert galaxy, the elliptical galaxy IC 4329.

Madejski, G. M.↗

A Gamma-Ray Burst Trigger Toolkit

The detection rate of a gamma-ray burst detector can be increased by using a count rate trigger with many accumulation times DELTAt and energy bands DELTAE Because a burst's peak flux varies when averaged over different DELTAt and DELTAE the nominal sensitivity (the numerical value of the peak flux) of a trigger system is less important than how much fainter a burst could be at the detection threshold as DELTAt and DELTAE are changed. The relative sensitivity of different triggers can be quantified by referencing the detection threshold back to the peak flux for a fiducial value of DELTAt and DELTA E. This mapping between peak flux values for different sets of DELTAt and DELTAE varies from burst to burst. Quantitative estimates of the burst detection rate for a given detector and trigger system can be based on the observed rate at a measured peak flux value in this fiducial trigger. Predictions of a proposed trigger's burst detection rate depend on the assumed burst population, and these predictions can be wildly in error for triggers that differ significantly from previous missions. I base the fiducial rate on the BATSE observations: 550 bursts per sky above a peak flux of 0.3 ph per square centimeter per second averaged over DELTAt=1.024 sec and DELTAE=50-300 keV. Using a sample of 100 burst lightcurves I find that triggering on any value of DELTAt that is a multiple of 0.064 sec decreases the average threshold peak flux on the 1.024 sec timescale by a factor of 0.6. Extending DELTAE to lower energies includes the large flux of the X-ray background, increasing the background count rate. Consequently a low energy DELTAE is advantageous only for very soft bursts. Whether a large fraction of the population of bright bursts is soft is disputed; the new population of X-ray Flashes is soft but relatively faint.

Band, David L.↗

SpaceCube Demonstration Platform

A document discusses how the HST SM4 SpaceCube flight spare was modified to create an experiment called the Space- Cube Demonstration Platform (SC DP) for use on the MISSE7 Space Station payload (in collaboration with NRL). It is designed to serve as an on-orbit platform for demonstrating advanced fault tolerance technologies. A simple C&DH (command and data handling) system was developed for the Virtex4 FPGAs (field programmable gate arrays). Both Virtex4s on each SpaceCube run the same program, and both receive incoming telemetry. The rad-hard service FPGA performs simple error checking to verify that the incoming telemetry is valid. The SpaceCube framework was modified to allow for new program files to be sent from the ground, to be stored on the SpaceCube, and to be executed through ground commands. Each SpaceCube Virtex4 FPGA has resources set aside for experiments that are functionally isolated from the C&DH system. The experiments communicate to the C&DH system through a set of dual port memories, and this area is where the fault-tolerance experiments are executed. With the use of Xilinx commercial Virtex4 FX60 FPGAs, the fault tolerant framework allows the system to recover from radiation upsets that occur in the rad-soft parts (Virtex4 FPGA logic, embedded PPCs in Virtex4 FPGAs, SDRAM and Flash), the C&DH system that runs simultaneously on both Virtex4 FPGAs that uses a robust telemetry packet structure, checksums, and the rad-hard service FPGA to validate incoming telemetry. The ability to be reconfigured from the ground while in orbit is a novel benefit, as well as is the onboard compression capabilities that allow compressed files from the ground to be uploaded to the SpaceCube.

Espinosa, Daniel↗

Wave optics simulations for new soft x-ray beamlines at NSLS-II

In this work, we performed fully- and partially-coherent synchrotron emission and propagation simulations with the "Synchrotron Radiation Workshop" computer code to analyze the performance of two soft X-ray beamlines under development at the National Synchrotron Light Source II: Soft X-ray Nanoprobe (SXN), and Angle-Resolved Photoemission Spectroscopy (ARPES) and Resonant Inelastic X-ray Scattering (RIXS) Imaging (ARI). The SXN beamline intends to provide high flux and high spatial resolution coherent soft X-ray imaging capabilities using both zone plate and lensless coherent imaging techniques. The ARI beamline aims to perform high flux ARPES and RIXS experiments with a focal spot size at the sample approaching 100 nm using highly-demagnifying mirrors in Kirkpatrick-Baez geometry. To accurately calculate the resolution and the degree of X-ray coherence provided by the two state-of-the-art beamlines, partial coherence effects are required to be taken into account in wave optics simulations for these two beamlines. In this talk, beamline performance parameters such as spot size, degree of coherence, flux, and energy resolution at the sample are presented. The effects of mirror surface slope errors on beamline performance were studied and some suggestions for further optimization are discussed.

36 MATERIALS SCIENCE↗

Universal Decoder for PPM of any Order

A recently developed algorithm for demodulation and decoding of a pulse-position- modulation (PPM) signal is suitable as a basis for designing a single hardware decoding apparatus to be capable of handling any PPM order. Hence, this algorithm offers advantages of greater flexibility and lower cost, in comparison with prior such algorithms, which necessitate the use of a distinct hardware implementation for each PPM order. In addition, in comparison with the prior algorithms, the present algorithm entails less complexity in decoding at large orders. An unavoidably lengthy presentation of background information, including definitions of terms, is prerequisite to a meaningful summary of this development. As an aid to understanding, the figure illustrates the relevant processes of coding, modulation, propagation, demodulation, and decoding. An M-ary PPM signal has M time slots per symbol period. A pulse (signifying 1) is transmitted during one of the time slots; no pulse (signifying 0) is transmitted during the other time slots. The information intended to be conveyed from the transmitting end to the receiving end of a radio or optical communication channel is a K-bit vector u. This vector is encoded by an (N,K) binary error-correcting code, producing an N-bit vector a. In turn, the vector a is subdivided into blocks of m = log2(M) bits and each such block is mapped to an M-ary PPM symbol. The resultant coding/modulation scheme can be regarded as equivalent to a nonlinear binary code. The binary vector of PPM symbols, x is transmitted over a Poisson channel, such that there is obtained, at the receiver, a Poisson-distributed photon count characterized by a mean background count nb during no-pulse time slots and a mean signal-plus-background count of ns+nb during a pulse time slot. In the receiver, demodulation of the signal is effected in an iterative soft decoding process that involves consideration of relationships among photon counts and conditional likelihoods of m-bit vectors of coded bits. Inasmuch as the likelihoods of all the m-bit vectors of coded bits mapping to the same PPM symbol are correlated, the best performance is obtained when the joint mbit conditional likelihoods are utilized. Unfortunately, the complexity of decoding, measured in the number of operations per bit, grows exponentially with m, and can thus become prohibitively expensive for large PPM orders. For a system required to handle multiple PPM orders, the cost is even higher because it is necessary to have separate decoding hardware for each order. This concludes the prerequisite background information. In the present algorithm, the decoding process as described above is modified by, among other things, introduction of an lbit marginalizer sub-algorithm. The term "l-bit marginalizer" signifies that instead of m-bit conditional likelihoods, the decoder computes l-bit conditional likelihoods, where l is fixed. Fixing l, regardless of the value of m, makes it possible to use a single hardware implementation for any PPM order. One could minimize the decoding complexity and obtain an especially simple design by fixing l at 1, but this would entail some loss of performance. An intermediate solution is to fix l at some value, greater than 1, that may be less than or greater than m. This solution makes it possible to obtain the desired flexibility to handle any PPM order while compromising between complexity and loss of performance.

Moision, Bruce E.↗

In-Flight Performance of the Soft X-Ray Spectrometer Detector System on ASTRO-H

The SXS instrument was launched aboard the Astro-H observatory on February 17, 2016. The SXS spectrometer is based on a high sensitivity x-ray calorimeter detector system that has been successfully deployed in many ground and sub-orbital spectrometers. The instrument was to provide essential diagnostics for nearly every class of x-ray emitting objects from the atmosphere of Jupiter to the outskirts of galaxy clusters, without degradation for spatially extended objects. The SXS detector system consisted of a 36-pixel cryogenic microcalorimeter array operated at a heat sink temperature of 50 mK. In pre-flight testing, the detector system demonstrated a resolving power of better than 1300 at 6 keV with a simultaneous band-pass from below 0.3 keV to above 12 keV with a timing precision better than 100 microsecond. In addition, a solid-state anti-coincidence detector was placed directly behind the detector array for background suppression. The detector error budget included the measured interference from the SXS cooling system and the spacecraft. Additional margin for on-orbit gain-stability, and on-orbit spacecraft interference were also included predicting an on-orbit performance that meets or exceeds the 7 eV FWHM at 6 keV requirement. The actual on-orbit spectral resolution was better than 5 eV FWHM at 6 keV, easily satisfying the instrument requirement. Here we discuss the actual on-orbit performance of the SXS detector system and compare this to performance in pre-flight testing and the on-orbit predictions. We will also discuss the on-orbit gain stability, additional on-orbit interference, and measurements of the on-orbit background.

X-ray astrophysics↗

Empirical relation between interstellar X-ray absorption and optical extinction

An empirical relation between interstellar X-ray absorption and optical extinction is derived from the correlation of measurements made on objects of large intrinsic diameter. The result is Av = 4.5 times 10 to the -22nd power N(H) mag, with the principal error being largely systematic in origin, where N(H) represents the column density of interstellar matter in the Brown and Gould model for the X-ray absorption coefficient. Applying this ratio to optically identified compact sources, it is concluded that sources in binary systems showing pronounced X-ray occultations have an intrinsic absorption equivalent to about 10 to the 22-nd power atoms per sq cm of interstellar matter and that there are a few compact sources where the absorption seems to be primarily interstellar in origin. The interstellar absorption expected in Cyg X-1 from the extinction of its optical counterpart is much greater than that suggested by X-ray spectra, which may be due to a soft X-ray component greater than that predicted by the power law fitted to higher energy data.

Gorenstein, P.↗

Soft Coiled Pneumatic Actuator with Integrated Length-Sensing Function for Feedback Control

SPIRA Coil actuators are formed from thin sheets of PET plastic laminated into a coil shape that unfurls like a “party horn” when inflated, while many soft actuators require large pressures to create only modest strains, SPIRA Coils can easily be designed and fabricated to extend over dramatic distances with relatively low working pressures. Internal metalized PET strips separate in the extended portion of the actuator, creating an electrical circuit with a resistance that corresponds to the actuator length. This paper presents and experimentally validates easy-to-use design models for the actuators’ self-retracting spring stiffness, its pneumatic extension force, and its internal length-sensing electrical resistance. Testing of the self-sensing capabilities demonstrates that the embedded sensor can be used to determine the actuator length with virtually no hysteresis. Feedback control with the resistance-based sensing resulted in length-control errors within 5% of the extended actuator length (i.e., 3 cm of 60 cm).

Greenwood, Jacob R. (ORCID:0000000310897854)↗

Correcting x ray spectra obtained from the AXAF VETA-I mirror calibration for pileup, continuum, background and deadtime

The VETA-I mirror was calibrated with the use of a collimated soft X-ray source produced by electron bombardment of various anode materials. The FWHM, effective area and encircled energy were measured with the use of proportional counters that were scanned with a set of circular apertures. The pulsers from the proportional counters were sent through a multichannel analyzer that produced a pulse height spectrum. In order to characterize the properties of the mirror at different discrete photon energies one desires to extract from the pulse height distribution only those photons that originated from the characteristic line emission of the X-ray target source. We have developed a code that fits a modeled spectrum to the observed X-ray data, extracts the counts that originated from the line emission, and estimates the error in these counts. The function that is fitted to the X-ray spectra includes a Prescott function for the resolution of the detector a second Prescott function for a pileup peak and a X-ray continuum function. The continuum component is determined by calculating the absorption of the target Bremsstrahlung through various filters correcting for the reflectivity of the mirror and convolving with the detector response.

Chartas, G.↗

Correcting X-ray spectra obtained from the AXAF VETA-I mirror calibration for pileup, continuum, background and deadtime

The VETA-I mirror was calibrated with the use of a collimated soft X-ray source produced by electron bombardment of various anode materials. The FWHM, effective area and encircled energy were measured with the use of proportional counters that were scanned with a set of circular apertures. The pulsers from the proportional counters were sent through a multichannel analyzer that produced a pulse height spectrum. In order to characterize the properties of the mirror at different discrete photon energies one desires to extract from the pulse height distribution only those photons that originated from the characteristic line emission of the X-ray target source. We have developed a code that fits a modeled spectrum to the observed X-ray data, extracts the counts that originated from the line emission, and estimates the error in these counts. The function that is fitted to the X-ray spectra includes a Prescott function for the resolution of the detector a second Prescott function for a pileup peak and a X-ray continuum function. The continuum component is determined by calculating the absorption of the target Bremsstrahlung through various filters, correcting for the reflectivity of the mirror and convolving with the detector response.

Chartas, G.↗

ASTRO-H Soft X-Ray Telescope (SXT)

ASTRO-H is an astrophysics satellite dedicated for X-ray spectroscopic study non-dispersively and to carry out survey complementally, which will be borne out of US-Japanese collaborative effort. Among the onboard instruments there are four conically approximated Wolter-I X-ray mirrors, among which two of them are soft X-ray mirrors\ of which the energy range is from a few hundred eV to 15 keY, currently being fabricated in the X-ray Optics Lab at Goddard Space Flight Center. The focal point instruments will be a calorimeter (SXS) and a CCD camera (SXI), respectively. The reflectors of the mirror are made of heat-formed aluminum substrate of the thickness gauged of 152 micron, 229 micron, and 305 micron of the alloy 5052 H-19, followed by epoxy replication on gold-sputtered smooth Pyrex cylindrical mandrels to acquire the X-ray reflective surface. The epoxy layer is 10 micron nominal and surface gold layer of 0.2 micron. Improvements on angular response over the Astro-El/Suzaku mirrors come from error reduction on the figure, the roundness, and the grazing angle/radius mismatching of the reflecting surface, and tighter specs and mechanical strength on supporting structure to reduce the reflector positioning and the assembly errors. In this paper, we report the results of calibration of the engineering model of SXT (EM), and project the quality of the flight mirrors.

Soong, Yang↗

A concatenated coded modulation scheme for error control

A concatenated coded modulation scheme for error control in data communications is presented. The scheme is achieved by concatenating a Reed-Solomon outer code and a bandwidth efficient block inner code for M-ary PSK modulation. Error performance of the scheme is analyzed for an AWGN channel. It is shown that extremely high reliability can be attained by using a simple M-ary PSK modulation inner code and relatively powerful Reed-Solomon outer code. Furthermore, if an inner code of high effective rate is used, the bandwidth expansion required by the scheme due to coding will be greatly reduced. The proposed scheme is particularly effective for high speed satellite communication for large file transfer where high reliability is required. Also presented is a simple method for constructing block codes for M-ary PSK modulation. Some short M-ary PSK codes with good minimum squared Euclidean distance are constructed. These codes have trellis structure and hence can be decoded with a soft decision Viterbi decoding algorithm.

Kasami, Tadao↗

A concatenated coded modulation scheme for error control

A concatenated coded modulation scheme for error control in data communications is presented. The scheme is achieved by concatenating a Reed-Solomon outer code and a bandwidth efficient block inner code for M-ary PSK modulation. Error performance of the scheme is analyzed for an AWGN channel. It is shown that extremely high reliability can be attained by using a simple M-ary PSK modulation inner code and a relatively powerful Reed-Solomon outer code. Furthermore, if an inner code of high effective rate is used, the bandwidth expansion required by the scheme due to coding will be greatly reduced. The proposed scheme is very effective for high speed satellite communications for large file transfer where high reliability is required. A simple method is also presented for constructing codes for M-ary PSK modulation. Some short M-ary PSK codes with good minimum squared Euclidean distance are constructed. These codes have trellis structure and hence can be decoded with a soft decision Viterbi decoding algorithm. Furthermore, some of these codes are phase invariant under multiples of 45 deg rotation.

Lin, Shu↗

A concatenated coded modulation scheme for error control

A concatenated coded modulation scheme for error control in data communications is presented. The scheme is achieved by concatenating a Reed-Solomon outer code and a bandwidth efficient block inner code for M-ary PSK modulation. Error performance of the scheme is analyzed for an AWGN channel. It is shown that extremely high reliability can be attained by using a simple M-ary PSK modulation inner code and relatively powerful Reed-Solomon outer code. Furthermore, if an inner code of high effective rate is used, the bandwidth expansion required by the scheme due to coding will be greatly reduced. The proposed scheme is particularly effective for high speed satellite communications for large file transfer where high reliability is required. Also presented is a simple method for constructing block codes for M-ary PSK modulation. Some short M-ary PSK codes with good minimum squared Euclidean distance are constructed. These codes have trellis structure and hence can be decoded with a soft-decision Viterbi decoding algorithm.

Kasami, Tadao↗

Model-predictive optimal control of ferrofluidic microrobots in three-dimensional space

Ferrofluid microrobots have emerged as promising tools for minimally invasive medical procedures. Their unique properties to navigate complex fluids and reach otherwise inaccessible regions of the human body have enabled new applications in targeted drug delivery, tissue engineering, and diagnostics. Here, this paper proposes a model-predictive controller for the external magnetic manipulation of ferrofluid microrobots in three dimensions (3D). The internal optimization routine of the controller determines appropriate changes in the applied electromagnetic field to minimize the deviation between the actual and desired trajectories of the microrobot. A linear system governing locomotion is derived and used as the equality constraints of the optimization problems associated with the feedback index. In addition to ferrofluid droplets, the controller presented in this work may be applied to other magnetically-pulled microrobots. Several experiments are performed to validate the controller and showcase its ability to adapt to changes in system parameters such as the desired tracking trajectory and the size, orientation, deformation, and velocity of the microrobot. The accuracy of the controller is analyzed for each experiment, and the average error is found to be within 0.25 mm for small velocities. An additional experiment is performed to demonstrate significant improvement over a PID controller that is optimally tuned using Bayesian optimization. The results presented in this paper suggest that the proposed control algorithm could enable new microrobotic capabilities in minimally invasive medical procedures, lab-on-a-chip applications, and microfluidics.

60 APPLIED LIFE SCIENCES↗