Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “small sample size”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Creation and physical aspects of luminescent patterns using helium ion microscopy

The helium ion microscope provides a sub-nanometer size He{sup +} ion beam which can be employed for materials modification. We demonstrate how material properties can be tuned in a helium ion microscope with very high precision using, as an example, the modification of the luminescence properties of a sodium chloride crystal. Although the beam size is extremely small, the actually affected sample volume is much bigger due to collision cascades. We have directly measured the diameter of the interaction volume of the 35 keV He{sup +} beam with a sodium chloride crystal using ionoluminescence. The experimental results are compared to stopping and range of ions in matter simulations and calculations of the point spread function.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

SEGUE 2: THE LEAST MASSIVE GALAXY

Segue 2, discovered by Belokurov et al., is a galaxy with a luminosity of only 900 L{sub Sun }. We present Keck/DEIMOS spectroscopy of 25 members of Segue 2-a threefold increase in spectroscopic sample size. The velocity dispersion is too small to be measured with our data. The upper limit with 90% (95%) confidence is {sigma}{sub v} < 2.2 (2.6) km s{sup -1}, the most stringent limit for any galaxy. The corresponding limit on the mass within the three-dimensional half-light radius (46 pc) is M{sub 1/2} < 1.5 (2.1) Multiplication-Sign 10{sup 5} M{sub Sun }. Segue 2 is the least massive galaxy known. We identify Segue 2 as a galaxy rather than a star cluster based on the wide dispersion in [Fe/H] (from -2.85 to -1.33) among the member stars. The stars' [{alpha}/Fe] ratios decline with increasing [Fe/H], indicating that Segue 2 retained Type Ia supernova ejecta despite its presently small mass and that star formation lasted for at least 100 Myr. The mean metallicity, ([Fe/H]) = -2.22 {+-} 0.13 (about the same as the Ursa Minor galaxy, 330 times more luminous than Segue 2), is higher than expected from the luminosity-metallicity relation defined by more luminous dwarf galaxy satellites of the Milky Way. Segue 2 may be the barest remnant of a tidally stripped, Ursa Minor-sized galaxy. If so, it is the best example of an ultra-faint dwarf galaxy that came to be ultra-faint through tidal stripping. Alternatively, Segue 2 could have been born in a very low mass dark matter subhalo (v{sub max} < 10 km s{sup -1}), below the atomic hydrogen cooling limit.

79 ASTRONOMY AND ASTROPHYSICS↗

Disentangling instrumental features of the 130 GeV Fermi line

We study the instrumental features of photons from the peak observed at E{sub γ} = 130 GeV in the spectrum of Fermi-LAT data. We use the sPlots algorithm to reconstruct — seperately for the photons in the peak and for background photons — the distributions of quantities such as incident angles, the recorded time, features of the spacecraft position, the zenith angles, the conversion type and details of the energy and direction reconstruction. The presence of a striking feature or cluster in such a variable would suggest an instrumental cause for the peak. In the publically available data, we find several suggestive features which may inform further studies by instrumental experts, though the size of the signal sample is too small to draw statistically significant conclusions.

79 ASTRONOMY AND ASTROPHYSICS↗

High-Precision Zinc Isotopic Measurement of Certified Reference Materials Relevant to the Environmental, Earth, Planetary and Biomedical Sciences

The zinc (Zn) stable isotope system has emerged as a powerful tool for investigating natural and anthropogenic processes of interest to disciplines extending from the Earth and planetary sciences to biomedical research. In nature, Zn isotopes typically fractionate ( 66 Zn/ 64 Zn) within the range of –1 and +1 permil (‰), and however, analytical limitations restrict the application of the Zn isotope system. Specifically, there is a lack of well-characterised matrix-matched reference materials covering most Zn isotope applications that are essential for validating laboratory performance, particularly given the contamination prone nature of Zn. Furthermore, the increasing demand for analysis of size-limited materials and sample types displaying small, sub-permil level Zn isotope variations requires improvements in measurement procedures. To address these limitations, the δ 66 Zn values of two pure Zn solutions and eighteen reference materials including the previously uncharacterised RGM-2, BCR-279, DOLT-4, DOLT-5, NASS-7, SBC-1, SGR-1b, MESS-3 and HISS-1, and the understudied QLO-1, SDC-1, BCR-414, NASS-6 and COQ-1 materials are reported. Furthermore, a 70 Zn- 67 Zn double-spike design has been implemented that routinely achieves intermediate measurement precision better than ± 0.02‰. This represents at least a two-fold improvement when compared with other double-spike designs, providing a robust platform of δ 66 Zn values required for quality control procedures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ships Passing in the Night: Spectroscopic Analysis of Two Ultra-faint Satellites in the Constellation Carina

Here, we present Magellan/IMACS, Anglo-Australian Telescope/AAOmega+2dF, and Very Large Telescope/GIRAFFE+FLAMES spectroscopy of the Carina II (Car II) and Carina III (Car III) dwarf galaxy candidates, recently discovered in the Magellanic Satellites Survey (MagLiteS). We identify 18 member stars in Car II, including two binaries with variable radial velocities and two RR Lyrae stars. The other 14 members have a mean heliocentric velocity ${v}_{\mathrm{hel}}=477.2\pm 1.2$ $\mathrm{km}\,{{\rm{s}}}^{-1}$ and a velocity dispersion of ${\sigma }_{v}={3.4}_{-0.8}^{+1.2}$ $\mathrm{km}\,{{\rm{s}}}^{-1}$. Assuming Car II is in dynamical equilibrium, we derive a total mass within the half-light radius of ${1.0}_{-0.4}^{+0.8}\times {10}^{6}$ ${M}_{\odot }$, indicating a mass-to-light ratio of ${369}_{-161}^{+309}$ ${M}_{\odot }$/${L}_{\odot }$. From equivalent width measurements of the calcium triplet lines of nine red giant branch (RGB) stars, we derive a mean metallicity of ${\rm{[Fe/H]}}=-2.44\pm 0.09$ with dispersion ${\sigma }_{{\rm{[Fe/H]}}}={0.22}_{-0.07}^{+0.10}$. Considering both the kinematic and chemical properties, we conclude that Car II is a dark-matter-dominated dwarf galaxy. For Car III, we identify four member stars, from which we calculate a systemic velocity of ${v}_{\mathrm{hel}}={284.6}_{-3.1}^{+3.4}$ $\mathrm{km}\,{{\rm{s}}}^{-1}$. The brightest RGB member of Car III has a metallicity of ${\rm{[Fe/H]}}\,=-1.97\pm 0.12$. Due to the small size of the Car III spectroscopic sample, we cannot conclusively determine its nature. Although these two systems have the smallest known physical separation (${\rm{\Delta }}d\sim 10\,\mathrm{kpc}$) among Local Group satellites, the large difference in their systemic velocities, $\sim 200\,\mathrm{km}\,{{\rm{s}}}^{-1}$, indicates that they are unlikely to be a bound pair. One or both systems are likely associated with the Large Magellanic Cloud (LMC), and may remain LMC satellites today. No statistically significant excess of γ-ray emission is found at the locations of Car II and Car III in eight years of Fermi-LAT data.

47 OTHER INSTRUMENTATION↗

Investigation of the response of a neutron-Hand monitor dedicated to the powder diffractometer at CENM-Maamora

Neutrons are used for the study of condensed matter. A neutron beam can indeed easily penetrate the solid material and undergo diffraction phenomena. Analysis of the diffused neutrons allows studying the atomic structure of crossed material. Their neutral electric charge makes them nondestructive probe of a great interest. In general, the size of the powder samples is very small and therefore the centering of the beam on these is very crucial. It is in this context we proceed to test a portable neutron monitor for centering and checking beam leak around the shielding to be installed around the diffractometer in TRIGA Mark II of CENM. It's consisting of a scintillation neutron detector NE426 ({sup 6}LiF + ZnS (Ag)) with electronic module and data acquisition system. The effect of radiation from radioactive neutrons source {sup 252}Cf is shown. Sensitivity and differential linearity are also performed. This study indicates several advantages of this detector with very good detection sensitivity and excellent stability during the counting time. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sampling Mars: Analytical requirements and work to do in advance

Sending a mission to Mars to collect samples and return them to the Earth for analysis is without doubt one of the most exciting and important tasks for planetary science in the near future. Many scientifically important questions are associated with the knowledge of the composition and structure of Martian samples. Amongst the most exciting questions is the clarification of the SNC problem- to prove or disprove a possible Martian origin of these meteorites. Since SNC meteorites have been used to infer the chemistry of the planet Mars, and its evolution (including the accretion history), it would be important to know if the whole story is true. But before addressing possible scientific results, we have to deal with the analytical requirements, and with possible pre-return work. It is unlikely to expect that a possible Mars sample return mission will bring back anything close to the amount returned by the Apollo missions. It will be more like the amount returned by the Luna missions, or at least in that order of magnitude. This requires very careful sample selection, and very precise analytical techniques. These techniques should be able to use minimal sample sizes and on the other hand optimize the scientific output. The possibility to work with extremely small samples should not obstruct another problem: possible sampling errors. As we know from terrestrial geochemical studies, sampling procedures are quite complicated and elaborate to ensure avoiding sampling errors. The significance of analyzing a milligram or submilligram sized sample and putting that in relationship with the genesis of whole planetary crusts has to be viewed with care. This leaves a dilemma on one hand, to minimize the sample size as far as possible in order to have the possibility of returning as many different samples as possible, and on the other hand to take a sample large enough to be representative. Whole rock samples are very useful, but should not exceed the 20 to 50 g range, except in cases of extreme inhomogeneity, because for larger samples the information tends to become redundant. Soil samples should be in the 2 to 10 g range, permitting the splitting of the returned samples for studies in different laboratories with variety of techniques.

Koeberl, Christian↗

Inorganic and protein crystal growth - Similarities and differences

Transport and interface kinetic concepts for the design and control of inorganic crystal growth experiments are reviewed, and their applications and limitations in protein crystal growth are considered. It is suggested that the interfacial concentration gradients are steeper for faster crystallization, and that the interfacial concentration distributions for the protein and the precipitant can differ significantly. Results show that uniformity in crystal composition and steady-state conditions in growth kinetics are favored by larger sample size, since surface-tension gradients drive strong in microgravity experiments and in small samples on earth.

Rosenberger, F.↗

Nanofluidic Size-Exclusion Chromatograph

Efforts are under way to develop a nanofluidic size-exclusion chromatograph (SEC), which would be a compact, robust, lightweight instrument for separating molecules of interest according to their sizes and measuring their relative abundances in small samples. About as large as a deck of playing cards, the nanofluidic SEC would serve, in effect, as a laboratory on a chip that would perform the functions of a much larger, conventional, bench-top SEC and ancillary equipment, while consuming much less power and much smaller quantities of reagent and sample materials. Its compactness and low power demand would render it attractive for field applications in which, typically, it would be used to identify and quantitate a broad range of polar and nonpolar organic compounds in soil, ice, and water samples. Size-exclusion chromatography is a special case of high-performance liquid chromatography. In a conventional SEC, a sample plug is driven by pressure along a column packed with silica or polymer beads that contain uniform nanopores. The interstices between, and the pores in, the beads collectively constitute a size-exclusion network. Molecules follow different paths through the size-exclusion network, such that characteristic elution times can be related to sizes of molecules: basically, smaller molecules reach the downstream end of the column after the larger ones do because the smaller ones enter minor pores and stay there for a while, whereas the larger ones do not enter the pores. The volume accessible to molecules gradually diminishes as their size increases. All molecules bigger than a pore size elute together. For most substances, the elution times and sizes of molecules can be correlated directly with molecular weights. Hence, by measuring the flux of molecules arriving at the downstream end as a function of time, one can obtain a liquid mass spectrum for the molecules present in a sample over a broad range of molecular weights.

Feldman, Sabrina↗

Particle size effects in particle-particle triboelectric charging studied with an integrated fluidized bed and electrostatic separator system

Fundamental studies of triboelectric charging of granular materials via particle-particle contact are challenging to control and interpret because of foreign material surfaces that are difficult to avoid during contacting and measurement. The measurement of particle charge itself can also induce charging, altering results. Here, we introduce a completely integrated fluidized bed and electrostatic separator system that charges particles solely by interparticle interactions and characterizes their charge on line. Particles are contacted in a free-surface fluidized bed (no reactor walls) with a well-controlled fountain-like flow to regulate particle-particle contact. The charged particles in the fountain are transferred by a pulsed jet of air to the top of a vertically-oriented electrostatic separator consisting of two electrodes at oppositely biased high voltage. The free-falling particles migrate towards the electrodes of opposite charge and are collected by an array of cups where their charge and size can be determined. We carried out experiments on a bidisperse size mixture of soda lime glass particles with systematically varying ratios of concentration. Results show that larger particles fall close to the negative electrode and smaller particles fall close to the positive electrode, consistent with theory and prior experiments that larger particles charge positively and smaller particles charge negatively. The segregation of particles by charge for one of the size components is strongest when its collisions are mostly with particles of the other size component; thus, small particles segregate most strongly to the negative sample when their concentration in the mixture is small (and analogous results occur for the large particles). Furthermore, we find additional size segregation due to granular flow, whereby the fountain becomes enriched in larger particles as the smaller particles are preferentially expelled from the fountain.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Anisotropic thermal transport in bulk hexagonal boron nitride

Hexagonal boron nitride (h-BN) has received great interest in recent years as a wide band-gap analog of graphene-derived systems along with its potential in a wide range of applications, for example, as the dielectric layer for graphene devices. However, the thermal transport properties of h-BN, which can be critical for device reliability and functionality, are little studied both experimentally and theoretically. The primary challenge in the experimental measurements of the anisotropic thermal conductivity of h-BN is that typically the sample size of h-BN single crystals is too small for conventional measurement techniques, as state-of-the-art technologies synthesize h-BN single crystals with lateral sizes only up to 2.5 mm and thicknesses up to 200 μm. Recently developed time-domain thermoreflectance (TDTR) techniques are suitable to measure the anisotropic thermal conductivity of such small samples, as it only requires a small area of 50 × 50 μm 2 for the measurements. Accurate atomistic modeling of thermal transport in bulk h-BN is also challenging due to the highly anisotropic layered structure. Here we conduct an integrated experimental and theoretical study on the anisotropic thermal conductivity of bulk h-BN single crystals over the temperature range of 100–500 K using TDTR measurements with multiple modulation frequencies and a full-scale numerical calculation of the phonon Boltzmann transport equation starting from first principles. Our experimental and numerical results compare favorably for both the in-plane and the through-plane thermal conductivities. We observe unusual temperature dependence and phonon-isotope scattering in the through-plane thermal conductivity of h-BN and elucidate their origins. Here, this article not only provides an important benchmark of the anisotropic thermal conductivity of h-BN, but also develops fundamental insight into the nature of phonon transport in this highly anisotropic layered material.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Measurements of the emanation of 37Ar and 39Ar from irradiated rocks and powders

The emanation fraction of radionuclides has been highlighted as a known source of uncertainty in the estimation of radionuclide source signatures from underground nuclear tests and other nuclear activities, particularly in the case of activation products. A system was developed at Pacific Northwest National Laboratory to quantify the emanation fraction of argon from samples ranging in particle size from powder to small rocks. Seven materials, two powders and five rock types, were neutron irradiated and the emanation fraction of 37Ar was measured. Additional measurements were made of the 39Ar emanation for four of these materials.

Johnson, Christine M.↗

Sterilization of N95 Respirators via Gamma Radiation: Comparison of Post-sterilization Efficacy

This study evaluated gamma irradiation for sterilization and reuse of two models of N95 respirators after gamma radiation sterilization as a method to increase availability of N95 respirators during a shortage. The Sandia National Laboratories Gamma Irradiation Facility was used to irradiate two different models of N95 filtering facepiece respirators at doses ranging from 0 kGy(tissue) to 50 kGy(tissue). The following tests were used to determine the efficacy of the respirator after irradiation sterilization: Ambient Aerosol Condensation Nuclei Counter Quantitative Fit Test, tensile test, strain cycling, oscillatory dynamic mechanical analysis, microscopic image analysis of fiber layers, and electrostatic field measurements. Both of the respirator models exhibited statistically significant changes after gamma irradiation as shown by the Quantitative Fit Test, electrostatic testing and the aerosol testing. The change in electrostatic capability of the filter reduced the efficiency of challenging particles near the 200 nm size by approximately 40-50%. Both tested respirators showed statistically significant changes associated with gamma sterilization. However, our results indicate that choices in materials and manufacturing methods to achieve N95 filtration lead to different magnitudes of damage when exposed to gamma radiation at sterilization relevant doses. This damage results in lower filtration performance. While our sample size (2 different types of respirators) was small, we did observe a change in electrostatic properties on a filter layer that coincided with the failure on the Quantitative Fit Test.

61 RADIATION PROTECTION AND DOSIMETRY↗

Sterilization of N95 Respirators via Gamma Radiation: Comparison of Post-sterilization Efficacy

This study evaluated gamma irradiation for sterilization and reuse of two models of N95 respirators after gamma radiation sterilization as a method to increase availability of N95 respirators during a shortage. The Sandia National Laboratories Gamma Irradiation Facility was used to irradiate two different models of N95 filtering facepiece respirators at doses ranging from 0 kGy(tissue) to 50 kGy(tissue). The following tests were used to determine the efficacy of the respirator after irradiation sterilization: Ambient Aerosol Condensation Nuclei Counter Quantitative Fit Test, tensile test, strain cycling, oscillatory dynamic mechanical analysis, microscopic image analysis of fiber layers, and electrostatic field measurements. Both of the respirator models exhibited statistically significant changes after gamma irradiation as shown by the Quantitative Fit Test, electrostatic testing and the aerosol testing. The change in electrostatic charge of the filter was correlated with a reduction in capturing particles near the 200 nm size by approximately 40-50%. Both tested respirators showed statistically significant changes associated with gamma sterilization. However, our results indicate that choices in materials and manufacturing methods to achieve N95 filtration lead to different magnitudes of damage when exposed to gamma radiation at sterilization relevant doses. This damage results in lower filtration performance. While our sample size (2 different types of respirators) was small, we did observe a change in electrostatic properties on a filter layer that coincided with the failure on the Quantitative Fit Test and reduction in aerosol filtering efficiency. Key Words: N95 respirators, respirators, airborne transmission, pandemic prevention, COVID-19, gamma sterilization

COVID-19↗

Measurements of emanation of Ar-37 and Ar-39 from irradiated rocks and powders

The emanation fraction of radionuclides has been highlighted as a known source of uncertainty in the estimation of radionuclide source signatures from underground nuclear tests and other nuclear activities, particularly in the case of activation products. A system was developed at Pacific Northwest National Laboratory to quantify the emanation fraction of argon from samples ranging in particle size from powder to small rocks. Seven materials, two powders and five rock types, were irradiated with fission spectrum neutrons and the emanation fraction of 37 Ar was measured. Additional measurements were made of the 39 Ar emanation for four of these materials.

36 MATERIALS SCIENCE↗

Microbiological testing of Skylab foods.

Review of some of the unique food microbiology problems and problem-generating circumstances the Skylab manned space flight program involves. The situations these problems arise from include: extended storage times, variations in storage temperatures, no opportunity to resupply or change foods after launch of the Skylab Workshop, first use of frozen foods in space, first use of a food-warming device in weightlessness, relatively small size of production lots requiring statistically valid sampling plans, and use of food as an accurately controlled part in a set of sophisticated life science experiments. Consideration of all of these situations produced the need for definite microbiological tests and test limits. These tests are described along with the rationale for their selection. Reported test results show good compliance with the test limits.

Heidelbaugh, N. D.↗

Portable 4.6 Micrometers Laser Absorption Spectrometer for Carbon Monoxide Monitoring and Fire Detection

The air quality aboard manned spacecraft must be continuously monitored to ensure crew safety and identify equipment malfunctions. In particular, accurate real-time monitoring of carbon monoxide (CO) levels helps to prevent chronic exposure and can also provide early detection of combustion-related hazards. For long-duration missions, environmental monitoring grows in importance, but the mass and volume of monitoring instruments must be minimized. Furthermore, environmental analysis beyond low-Earth orbit must be performed in-situ, as sample return becomes impractical. Due to their small size, low power draw, and performance reliability, semiconductor-laser-based absorption spectrometers are viable candidates for this purpose. To reduce instrument form factor and complexity, the emission wavelength of the laser source should coincide with strong fundamental absorption lines of the target gases, which occur in the 3 to 5 micrometers wavelength range for most combustion products of interest, thereby reducing the absorption path length required for low-level concentration measurements. To address the needs of current and future NASA missions, we have developed a prototype absorption spectrometer using a semiconductor quantum cascade laser source operating near 4.6 micrometers that can be used to detect low concentrations of CO with a compact single-pass absorption cell. In this study, we present the design of the prototype instrument and report on measurements of CO emissions from the combustion of a variety of aerospace plastics.

Tunable Environmental Laser Spectrometer (TELS)↗

Characterization of Evidence for Human System Risk Assessment

Understanding the kinds of evidence available and using the best evidence to answer a question is critical to evidenced-based decision-making, and it requires synthesis of evidence from a variety of sources. Categorization of human system risks in spaceflight, in particular, focuses on how well the integration and interpretation of all available evidence informs the risk statement that describes the relationship between spaceflight hazards and an outcome of interest. A mature understanding and categorization of these risks requires: 1) sufficient characterization of risk, 2) sufficient knowledge to determine an acceptable level of risk (i.e., a standard), 3) development of mitigations to meet the acceptable level of risk, and 4) identification of factors affecting generalizability of the evidence to different design reference missions. In the medical research community, evidence is often ranked by increasing confidence in findings gleaned from observational and experimental research (e.g., "levels of evidence"). However, an approach based solely on aspects of experimental design is problematic in assessing human system risks for spaceflight. For spaceflight, the unique challenges and opportunities include: (1) The independent variables in most evidence are the hazards of spaceflight, such as space radiation or low gravity, which cannot be entirely duplicated in terrestrial (Earth-based) analogs, (2) Evidence is drawn from multiple sources including medical and mission operations, Lifetime Surveillance of Astronaut Health (LSAH), spaceflight research (LSDA), and relevant environmental & terrestrial databases, (3) Risk metrics based primarily on LSAH data are typically derived from available prevalence or incidence data, which may limit rigorous interpretation, (4) The timeframe for obtaining adequate spaceflight sample size (n) is very long, given the small population, (5) Randomized controlled trials are unattainable in spaceflight, (6) Collection of personal and environmental data on the astronaut population may create opportunities for advanced analytics and human-environment modeling that goes beyond that achieved in isolated experimental designs; and (7) Translation of relevant research to operations is a complex, transdisciplinary enterprise in which the approach must apply across the physical, biological, behavioral, and social sciences. The approach to synthesizing evidence must address both source and fidelity of data, and reflect the most general attributes of quality of evidence in science and engineering: reliability and validity. The authors are developing a two-factor approach which includes the various kinds of evidence required to understand risks and for the integrated interpretation of all evidence that is essential to develop standards and countermeasures. A unified framework for aggregating and assessing different kinds of evidence provides a consistent, traceable, evidence-based decision-making process to translate research to operations in an environment where engineers, scientists, physicians, and managers all engage in analyzing the trade space of vehicle design, standards, requirements and solutions for spaceflight.

Steinberg, S. L.↗