Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “shielding design”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Intensity-Modulated Advanced X-ray Source (IMAXS) for Homeland Security Applications

X-ray cargo inspection systems for the detection and verification of threats and contraband require high x-ray energy and high x-ray intensity to penetrate dense cargo. On the other hand, low intensity is desirable to minimize the radiation footprint. A collaboration between HESCO/PTSE Inc., Schonberg Research Corporation and Rapiscan Laboratories, Inc. has been formed in order to design and build an Intensity-Modulated Advanced X-ray Source (IMAXS). Such a source would allow cargo inspection systems to achieve up to two inches greater imaging penetration capability, while retaining the same average radiation footprint as present fixed-intensity sources. Alternatively, the same penetration capability can be obtained as with conventional sources with a reduction of the average radiation footprint by about a factor of three. The key idea is to change the intensity of the source for each x-ray pulse based on the signal strengths in the inspection system detector array during the previous pulse. In this paper we describe methods to accomplish pulse-to-pulse intensity modulation in both S-band (2998 MHz) and X-band (9303 MHz) linac sources, with diode or triode (gridded) electron guns. The feasibility of these methods has been demonstrated. Additionally, we describe a study of a shielding design that would allow a 6 MV X-band source to be used in mobile applications.

07 ISOTOPE AND RADIATION SOURCES↗

An Assessment of the Penetrations in the First Wall Required for Plasma Measurments for Control of an Advanced Tokamak Plasma Demo

A Demonstration tokamak (Demo) is an essential next step toward a magnetic-fusion based reactor. One based on advanced-tokamak (AT) plasmas is especially appealing because of its relative compactness. However, it will require many plasma measurements to provide the necessary signals to feed to ancillary systems to protect the device and control the plasma. This note addresses the question of how much intrusion into the blanket system will be required to allow the measurements needed to provide the information required for plasma control. All diagnostics will require, at least, the same shielding designs as planned for ITER, while having the capability to maintain their calibration through very long pulses. Much work is required to define better the measurement needs and the quantity and quality of the measurements that will have to be made, and how they can be integrated into the other tokamak structures.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Mitigation of Electromagnetic Pulse (EMP) Effects from Short-Pulse Lasers and Fusion Neutrons

Our research focused on obtaining a fundamental understanding of the source and properties of EMP at the Titan PW(petawatt)-class laser facility. The project was motivated by data loss and damage to components due to EMP, which can limit diagnostic techniques that can be used reliably at short-pulse PW-class laser facilities. Our measurements of the electromagnetic fields, using a variety of probes, provide information on the strength, time duration, and frequency dependence of the EMP. We measure electric field strengths in the 100's of kV/m range, durations up to 100 ns, and very broad frequency response extending out to 5 GHz and possibly beyond. This information is being used to design shielding to mitigate the effects of EMP on components at various laser facilities. We showed the need for well-shielded cables and oscilloscopes to obtain high quality data. Significant work was invested in data analysis techniques to process this data. This work is now being transferred to data analysis procedures for the EMP diagnostics being fielded on the National Ignition Facility (NIF). In addition to electromagnetic field measurements, we measured the spatial and energy distribution of electrons escaping from targets. This information is used as input into the 3D electromagnetic code, EMSolve, which calculates time dependent electromagnetic fields. The simulation results compare reasonably well with data for both the strength and broad frequency bandwidth of the EMP. This modeling work required significant improvements in EMSolve to model the fields in the Titan chamber generated by electrons escaping the target. During dedicated Titan shots, we studied the effects of varying laser energy, target size, and pulse duration on EMP properties. We also studied the effect of surrounding the target with a thick conducting sphere and cube as a potential mitigation approach. System generated EMP (SGEMP) in coaxial cables does not appear to be a significant at Titan. Our results are directly relevant to planned short-pulse ARC (advanced radiographic capability) operation on NIF.

36 MATERIALS SCIENCE↗

An Analysis of Frenkel Defects and Backgrounds Modeling for SuperCDMS Dark Matter Searches

Years of astrophysical observations suggest that dark matter comprises more than $\sim$ 80 % of all matter in the universe. Particle physics theories favor a weakly-interacting particle that could be directly detected in terrestrial experiments. The Super Cryogenic Dark Matter Search (SuperCDMS) Collaboration operates world-leading experiments to directly detect dark matter interacting with ordinary matter. The SuperCDMS Soudan experiment searched for weakly interacting massive particles (WIMPs) via their elastic-scattering interactions with nuclei in low-temperature germanium detectors. During the operation of the SuperCDMS Soudan experiment, $^{210}$Pb sources were installed to study background rejection of the Ge detectors. Data from these sources were used to investigate energy loss associated with Frenkel defect formation in germanium crystals at mK temperatures. The spectrum of $^{206}$Pb nuclear recoils was examined near its expected 103 keV endpoint energy to extract the first experimentally determined average displacement threshold energy of 19.7 $\pm$ 0.5 (stat) $\pm$ 0.1 (syst) eV for germanium. This has implications for the sensitivity of future germanium-based dark matter searches including the SuperCDMS SNOLAB experiment. The SuperCDMS SNOLAB experiment will employ germanium and silicon detectors to improve current WIMP-search results by at least one order of magnitude for masses $\leq$ 10 GeV/c$^2$. This will require substantial shielding against cosmogenic and radiogenic backgrounds. The SuperCDMS SNOLAB passive shield will be permanent for the duration of the experiment so extensive simulations were undertaken to optimize the shield design. This resulted in a design of an outer layer of 60 cm of water, a middle layer of 20 cm of lead, and 30 cm of polyethylene which limits the background rate to that required for the primary physics goals of the experiments. The experiment will begin operations in 2020 and care must be taken during the construction phase to limit exposure to the $\pm$ 135 Bq/m$^3$ radon activity in the laboratory. The daughter products of $^{222}$Rn can attach to nearby surfaces leaving long-lived $^{210}$Pb in place for the duration of the experiment. For non-line-of-sight surfaces of the polyethylene shield, the maximum allowable $^{210}$Pb activity is 10,000 nBq/cm$^2$. A study was conducted to experimentally determine the contamination rate of polyethylene and copper by exposing samples for 83 days at SNOLAB. From the resulting surface activities, obtained from high-sensitivity measurements of alpha emissivity using the XIA UltraLo-1800 spectrometer, the average $^{210}$Pb plate-out rate was determined to be 249 and 423 atoms/day/cm$^2$ for polyethylene and copper, respectively. A time-dependent model of alpha activity was

79 ASTRONOMY AND ASTROPHYSICS↗

HZETRN: neutron and proton production in quasi-elastic scattering of GCR heavy-ions

The development of transport models for radiation shielding design and evaluation has provided a series of deterministic computer codes that describe galactic cosmic radiation (GCR), solar particle events, and experimental beams at particle accelerators. These codes continue to be modified to accommodate new theory and improvements to the particle interaction database (Cucinotta et al., 1994, NASA Technical Paper 3472, US Government Printing Office, Washington DC). The solution employed by the heavy-ion transport code HZETRN was derived with the assumption that nuclear fragments are emitted with the same velocity as the incident ion through velocity conserving nuclear interactions. This paper presents a version of the HZETRN transport code that provides a more realistic distribution of the energy of protons and neutrons emitted from GCR interactions in shields. This study shows that the expected GCR dose equivalent is lower than previously calculated for water shields that are less than 110 g cm-2 thick. Calculations of neutron energy spectra in low Earth orbit indicate substantial contributions from relativistic neutrons. c2001 Elsevier Science Ltd. All rights reseved.

NASA Center LaRC↗

Mars Surface Ionizing Radiation Environment: Need for Validation

Protection against the hazards from exposure to ionizing radiation remains an unresolved issue in the Human Exploration and Development of Space (HEDS) enterprise [1]. The major uncertainty is the lack of data on biological response to galactic cosmic ray (GCR) exposures but even a full understanding of the physical interaction of GCR with shielding and body tissues is not yet available and has a potentially large impact on mission costs. "The general opinion is that the initial flights should be short-stay missions performed as fast as possible (so-called 'Sprint' missions) to minimize crew exposure to the zero-g and space radiation environment, to ease requirements on system reliability, and to enhance the probability of mission success." The short-stay missions tend to have long transit times and may not be the best option due to the relatively long exposure to zero-g and ionizing radiation. On the other hand the short-transit missions tend to have long stays on the surface requiring an adequate knowledge of the surface radiation environment to estimate risks and to design shield configurations. Our knowledge of the surface environment is theoretically based and suffers from an incomplete understanding of the physical interactions of GCR with the Martian atmosphere, Martian surface, and intervening shield materials. An important component of Mars surface robotic exploration is the opportunity to test our understanding of the Mars surface environment. The Mars surface environment is generated by the interaction of Galactic Cosmic Rays (GCR) and Solar Particle Events (SPEs) with the Mars atmosphere and Mars surface materials. In these interactions, multiple charged ions are reduced in size and secondary particles are generated, including neutrons. Upon impact with the Martian surface, the character of the interactions changes as a result of the differing nuclear constituents of the surface materials. Among the surface environment are many neutrons diffusing from the Martian surface and especially prominent are energetic neutrons with energies up to a few hundred MeV. Testing of these computational results is first supported by ongoing experiments at the Brookhaven National Laboratory but equally important is the validation to the extent possible by measurements on the Martian surface. Such measurements are limited by power and weight requirements of the specific mission and simplified instrumentation by necessity lacks the full discernment of particle type and spectra as is possible with laboratory experimental equipment. Yet, the surface measurements are precise and a necessary requisite to validate our understanding of the surface environment. At the very minimum the surface measurements need to provide some spectral information on the neutron environment. Of absolute necessity is the precise knowledge of the detector response functions for absolute comparisons between the computational model of the surface environment and the detector measurements on the surface.

Wilson, J. W.↗

Electromagnetic Analysis of ITER Electron Cyclotron Emission Components and Support Structures for the Preliminary Design Review

The ITER electron cyclotron emission (ECE) diagnostic system is located at Design Shield Module (DSM) 2, Equatorial Port (EP) 9 to measure electron temperature profile and electron temperature fluctuations and also to assess nonthermal electron distributions via the oblique view. Therefore, ECE has both radial and oblique views with two couples of mirrors for two different optical views. This ECE diagnostic system shall be exposed to significant power due to unabsorbed electron cyclotron heating power in the plasma. It shall also receive large electromagnetic (EM) loads up to 100 MN/m 3 force density due to the eddy currents generated by the short 16-ms transient plasma disruption. The global EM models of EP12 and EP11 with the worst case of plasma disruption Major Disruption Downward Exponential 16 ms Category III (MD_DW_EXP16MS_CATIII) have been provided by ITER. However, the support structure for these critical components, including four mirrors, is still under the design and development phase, especially during the period of preliminary design reviews (PDRs). For those small in-vessel components that are not modeled explicitly for the PDRs, we can extract the magnetic field (B) data and flux variations (dB/dt) at those locations from the global model and then use the B and dB/dt method to calculate the eddy currents, EM forces, and torques on those components in the local submodels. In conclusion, this paper will present the detailed PDR EM analysis results of the ECE components and support structures.

Electromagnetic↗

The research progress of some key problems about the protection of industrial electron irradiation accelerator - Paper 9

In the last decades, electronic irradiation accelerator has made great progress and been widely used in fields. Because of its distinguishing feature of reliability and safety, electronic irradiation accelerator has attracted more attention of the investors, and created a huge economic value and social benefits. It will become the mainstream equipment of irradiation processing industry in future. So the further study of the shielding design around irradiation accelerator is of great significance. Different designs of ventilation duct will greatly influence dose rate of the exit. Because of the high dose rate under the target, it is suitable to use multi-tortuous duct when duct locating under target. It will reduce the dose rate about 3 orders of magnitude at the exit that add one backscattering interface in duct. Choose reasonable diameter and angle of embedded duct so that photons scatter as much as possible. We can use multiple small diameter ducts to replace large diameter duct. The system of Mini-DDL, Gamma detector and PC give a better reflection on the running statue of accelerator, its perfect usability can produce intuitive images for analyzed, it is important and helpful for workers and researchers to know about the radiation level of machine and environment. The measured results along the maze show that the maze must be long enough in order to achieve the desired shielding thickness. In future, we will combine the different kinds and motor patterns of body models, Monte Carlo programs, real time monitoring system with theoretical calculations to explore how the radiation field around accelerator has impact on human organs, get the dose distribution of body models so that improve the radiation protection to electron accelerator. (authors)

43 PARTICLE ACCELERATORS↗

Thermal Management and Thermal Protection Systems

During my internship in the Thermal Design Branch (ES3), I contributed to two main projects: i) novel passive thermal management system for future human exploration, ii) AVCOAT undercut thermal analysis. i) As NASA prepares to further expand human and robotic presence in space, it is well known that spacecraft architectures will be challenged with unprecedented thermal environments. Future exploration activities will have the need of thermal management systems that can provide higher reliability, mass and power reduction and increased performance. In an effort to start addressing the current technical gaps the NASA Johnson Space Center Passive Thermal Discipline has engaged in technology development activities. One of these activities was done through an in-house Passive Thermal Management System (PTMS) design for a lunar lander. The proposed PTMS, functional in both microgravity and gravity environments, consists of three main components: a heat spreader, a novel hybrid wick Variable Conductance Heat Pipe (VCHP), and a radiator. The aim of this PTMS is to keep electronics on a vehicle within their temperature limits (0 and 50 C for the current design) during all mission phases including multiple lunar day/night cycles. The VCHP was tested to verify its thermal performance. I created a thermal math model using Thermal Desktop (TD) and analyzed it to predict the PTMS performance. After testing, the test data provided a means to correlate the thermal math model. This correlation took into account conduction and convection heat transfer, representing the actual benchtop test. Since this PTMS is proposed for space missions, a vacuum test will be taking place to provide confidence that the system is functional in space environments. Therefore, the model was modified to include a vacuum chamber with a liquid nitrogen shroud while taking into account conduction and radiation heat transfer. Infrared Lamps were modelled and introduced into the model to simulate the sun's rays directly impinging on the system. Heating rate of the lamps were calculated by knowing fraction of emitted energy in a wavelength interval and the filament temperature. This version of the model can be used to predict performance of the system under vacuum with extreme cold or hot conditions. Initial testing of the PTMS showed promise, and the thermal math model predicts even better performance in thermal vacuum testing. ii) Thermal Protection Systems (TPS) are required for vehicles which enter earth's atmosphere to protect from aerodynamic heating caused by the friction between the vehicle and atmospheric gases. Orion's heat shield design has two aspects which needed to be analyzed thermally: i) a small excess of adhesive used to bond the outer AVCOAT layer to the inner composite structure tends to seep from under the AVCOAT and form a small bead in between two bricks of AVCOAT, ii) a silicone rubber with different thermophysical properties than AVCOAT fills the gap between two bricks of AVCOAT. I created a thermal model using TD to determine temperature differences that are caused by these two features. To prevent false results, all TD models must be verified against something known. In this case, the TD model was correlated to CHAR, an ablation modelling software used to analyze TPS. Analyzing a node far from the concerning features, we saw that the TD model data match CHAR data, verifying the TD model. Next, the temperature of the silicone rubber as well as the bead of adhesive were analyzed to determine if they exceeded allowable temperatures. It was determined that these two features do not have a significant effect on the max temperature of the heat shield. This model can be modified to check temperatures at various locations of the heat shield where the composite thickness varies.

Hasnain, Aqib↗

Technology Demonstration Missions

Technology Demonstration Missions (TDM) is in its third year of execution, being initiated in 2010 and baselined in January of 2012. There are 11 projects that NASA Marshall Space Flight Center (MSFC) has contributed to or led: (1) Evolvable Cryogenics (eCryo): Cyrogenic Propellant Storage and Transfer Engineering Development Unit (EDU), a proof of manufacturability effort, used to enhance knowledge and technology related to handling cryogenic propellants, specifically liquid hydrogen. (2) Composites for Exploration Upper Stage (CEUS): Design, build, test, and address flight certification of a large composite shell suitable for the second stage of the Space Launch System (SLS). (3) Deep Space Atomic Clock (DSAC): Spaceflight to demo small, low-mass atomic clock that can provide unprecedented stability for deep space navigation. (4) Green Propellant Infusion Mission (GPIM): Demo of high-performance, green propellant propulsion system suitable for Evolved Expendable Launch Vehicle (EELV) Secondary Payload Adapter (ESPA)-class spacecraft. (5) Human Exploration Telerobotics (HET): Demonstrating how telerobotics, remote control of a variety of robotic systems, can take routine, highly repetitive, dangerous or long-duration tasks out of human hands. (6) Laser Communication Relay Demo (LCRD): Demo to advance optical communications technology toward infusion into deep space and near Earth operational systems, while growing the capabilities of industry sources. (7) Low Density Supersonic Decelerator (LDSD): Demo new supersonic inflatable decelerator and parachute technologies to enable Mars landings of larger payloads with greater precision at a wider range of altitudes. (8) Mars Science Laboratory (MSL) Entry Descent & Landing Instrumentation (MEDLI): Demo of embedded sensors embedded in the MSL heat shield, designed to record the heat and atmospheric pressure experienced during the spacecraft's high-speed, hot entry in the Martian atmosphere. (9) Solar Electric Propulsion (SEP): 50-kW class spacecraft that uses flexible blanket solar arrays for power generation and an electric propulsion system that delivers payload from low-Earth orbit to higher orbits. (10) Solar Sail Demonstration (SSD): Demo to validate sail deployment techniques for solar sails that are propelled by the pressure of sunlight. (11) Terrestrial HIAD Orbit Reentry (THOR): Demo of a 3.7-m Hypersonic Inflatable Aerodynamic Decelerator (HIAD) entry vehicle to test second generation aerothermal performance and modeling.

McDougal, John↗

Background simulations and shielding calculations

Key improvements in the sensitivity of the underground particle astrophysics experiments can only be achieved if the radiation causing background events in detectors is well understood and proper measures are taken to suppress it. The background radiation arising from radioactivity and cosmic-ray muons is discussed here together with the methods of its suppression. Different shielding designs are considered to attenuate gamma-rays and neutrons coming from radioactivity in rock and lab walls. Purity of materials used in detector construction is analysed and the background event rates due to the presence of radioactive isotopes in detector components are discussed. Event rates in detectors caused by muon-induced neutrons with and without active veto systems are presented leading to the requirements for the depth of an underground laboratory and the efficiency of the veto system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ACCURATE TEMPERATURE MEASUREMENTS IN A NATURALLY-ASPIRATED RADIATION SHIELD

Experiments and calculations were conducted with a 0.13 mm fine wire thermocouple within a naturally-aspirated Gill radiation shield to assess and improve the accuracy of air temperature measurements without the use of mechanical aspiration, wind speed or radiation measurements. It was found that this thermocouple measured the air temperature with root-mean-square errors of 0.35 K within the Gill shield without correction. A linear temperature correction was evaluated based on the difference between the interior plate and thermocouple temperatures. This correction was found to be relatively insensitive to shield design and yielded an error of 0.16 K for combined day and night observations. The correction was reliable in the daytime when the wind speed usually exceeds 1 m s{sup -1} but occasionally performed poorly at night during very light winds. Inspection of the standard deviation in the thermocouple wire temperature identified these periods but did not unambiguously locate the most serious events. However, estimates of sensor accuracy during these periods is complicated by the much larger sampling volume of the mechanically-aspirated sensor compared with the naturally-aspirated sensor and the presence of significant near surface temperature gradients. The root-mean-square errors therefore are upper limits to the aspiration error since they include intrinsic sensor differences and intermittent volume sampling differences.

47 OTHER INSTRUMENTATION↗

Analytical Model of High-Velocity Impact of a Deformable Projectile Against Textile-Based Composites

Textile-based composites are used in manufacturing of ballistic shields due to their favorable combination of mechanical properties which enables weight saving and efficiency while retaining or even improving ballistic performance. Predictive models are an important tool in reducing experimental tests which are still an important step in ballistic shield design. Among those, analytical models provide less accurate results but require far less computational cost than numerical models and can be used for preliminary analyses. Many authors in the literature have developed analytical models for high-velocity impact on textile-based composites based on wave propagation theory and an energy equilibrium approach. The main limitation of these models is the assumption of rigid projectile which leads to the underestimation of the ballistic limit for soft core projectiles, which are a very common type of threat for this kind of protection. For this reason, an enhanced version of these models is reported in this paper, which releases the assumption of rigid projectile and adds erosion and deformation of the projectile to the formulation. Ballistic tests were performed on panels manufactured from layers of Kevlar 29 plain weave fabric embedded in an epoxy matrix. An insight into the different kinds of energy absorption considered by the model shows that projectile deformation plays an important role in the dissipation of the kinetic energy of the projectile in case of intermediate impact velocity. For this reason, the present model delivers more accurate results than the models present in the literature. In particular, the estimation of the ballistic limit is drastically improved which is a key step in ballistic shields optimization.

36 MATERIALS SCIENCE↗

Renal Shielding and Dosimetry for Patients With Severe Systemic Sclerosis Receiving Immunoablation With Total Body Irradiation in the Scleroderma: Cyclophosphamide or Transplantation Trial

Purpose: To describe renal shielding techniques and dosimetry in delivering total body irradiation (TBI) to patients with severe systemic sclerosis (SSc) enrolled in a hematopoietic stem cell transplant protocol. Methods and Materials: The Scleroderma: Cyclophosphamide or Transplantation (SCOT) protocol uses a lymphoablative preparative regimen including 800 cGy TBI delivered in two 200-cGy fractions twice a day before CD34{sup +} selected autologous hematopoietic stem cell transplantation. Lung and kidney doses are limited to 200 cGy to protect organs damaged by SSc. Kidney block proximity to the spinal cord was investigated, and guidelines were developed for acceptable lumbar area TBI dosing. Information about kidney size and the organ shifts from supine to standing positions were recorded using diagnostic ultrasound (US). Minimum distance between the kidney blocks (dkB) and the lumbar spine region dose was recorded, and in vivo dosimetry was performed at several locations to determine the radiation doses delivered. Results: Eleven patients were treated at our center with an anteroposterior (AP)/posteroanterior (PA) TBI technique. A 10% to 20% dose inhomogeneity in the lumbar spine region was achieved with a minimum kidney block separation of 4 to 5 cm. The average lumbar spine dose was 179.6 {+-} 18.1 cGy, with an average dkB of 5.0 {+-} 1.0 cm. Kidney block shield design was accomplished using a combination of US and noncontrast computerized tomography (CT) or CT imaging alone. The renal US revealed a wide range of kidney displacement from upright to supine positions. Overall, the average in vivo dose for the kidney prescription point was 193.4 {+-} 5.1 cGy. Conclusions: The dose to the kidneys can be attenuated while maintaining a 10% to 20% dose inhomogeneity in the lumbar spine area. Kidneys were localized more accurately using both US and CT imaging. With this technique, renal function has been preserved, and the study continues to enroll patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Scatter radiation intensities around a clinical digital breast tomosynthesis unit and the impact on radiation shielding considerations

Purpose: To measure the scattered radiation intensity around a clinical digital breast tomosynthesis (DBT) unit and to provide updated data for radiation shielding design for DBT systems with tungsten-anode x-ray tubes. Methods: The continuous distribution of scattered x-rays from a clinical DBT system (Hologic Selenia Dimensions) was measured within an angular range of 0°–180° using a linear-array x-ray detector (X-Scan 0.8f3-512, Detection Technology, Inc., Finland), which was calibrated for the x-ray spectrum range of the DBT unit. The effects of x-ray field size, phantom size, and x-ray kVp/filter combination were investigated. Following a previously developed methodology by Simpkin, scatter fraction was determined for the DBT system as a function of angle around the phantom center. Detailed calculations of the scatter intensity from a DBT system were demonstrated using the measured scatter fraction data. Results: For the 30 and 35 kVp acquisition, the scatter-to-primary-ratio and scatter fraction data closely matched with data previously measured by Simpkin. However, the measured data from this study demonstrated the nonisotropic distribution of the scattered radiation around a DBT system, with two strong peaks around 25° and 160°. The majority scatter radiation (>70%) originated from the imaging detector assembly, instead of the phantom. With a workload from a previous survey performed at MGH, the scatter air kerma at 1 m from the phantom center for wall/door is 1.76 × 10{sup −2} mGy patient{sup −1}, for floor is 1.64 × 10{sup −1} mGy patient{sup −1}, and for ceiling is 3.66 × 10{sup −2} mGy patient{sup −1}. Conclusions: Comparing to previously measured data for mammographic systems, the scatter air kerma from Holgoic DBT is at least two times higher. The main reasons include the harder primary beam with higher workload (measured with total mAs/week), added tomosynthesis acquisition, and strong small angle forward scattering. Due to the highly conservative initial assumptions, the shielding recommendation from NCRP Report 147 is still sufficient for the Hologic DBT system given the workload from a previous survey at MGH. With the data provided from this study, accurate shielding calculation can be performed for Hologic DBT systems with specific workload and barrier distance.

61 RADIATION PROTECTION AND DOSIMETRY↗

Strategy to safely enable X-ray computed tomography examination of highly radioactive tristructural isotropic nuclear fuel

Nondestructive post-irradiation examination of nuclear fuels and materials is useful in collecting data to inform commercial licensing of new nuclear concepts. This work details the planning, shielding design, and workflow of an X-ray computed tomography examination of an irradiated AGR-5/6/7 fuel compact with a dose rate of 1318 R/hr on contact from both β and ɤ-ray radiation with 120 R/hr of the dose rate coming exclusively from ɤ-rays. Post-irradiation examination of highly radioactive samples can help reduce the timeframe from conceptualization of novel nuclear concepts to their commercial implementation as not only is less time spent waiting for experiments to decay away to acceptable levels for examinations, but data from these experiments can more quickly inform model efforts and subsequent experiments. While this work represents the hottest radiological sample that has been openly transported and examined at Idaho National Laboratory’s Irradiated Materials Characterization Laboratory to date, it is anticipated that this work and its lessons learned will facilitate future examinations of similar or even more radioactive specimens.

42 - ENGINEERING↗

Production and use of nuclear parameter covariance data: an overview of challenging cross cutting scientific issues

Nuclear data users’ requirements for uncertainty data started already in the seventies, when several fast reactor projects did use extensively “statistical data adjustments” to meet data improvement for core and shielding design. However, it was only ~20–30 years later that a major effort started to produce scientifically based covariance data and in particular since ~2005. Most work has been done since then with spectacular achievements and enhanced understanding both of the uncertainty evaluation process and of the data utilization in V&V. This paper summarizes some key developments and still open challenges.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A neutron recoil-spectrometer for measuring yield and determining liner areal densities at the Z facility

For this study, a proof-of-principle CR-39 based neutron-recoil-spectrometer was built and fielded on the Z facility. Data from this experiment match indium activation yields within a factor of 2 using simplified instrument response function (IRF) models. The data also demonstrates the need for neutron shielding in order to infer liner areal densities. A new shielded design has been developed. The spectrometer is expected to achieve signal-to-background greater than 2 for the down-scattered neutron signal and greater than 30 for the primary signal.

47 OTHER INSTRUMENTATION↗