Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “sensor array”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Development of Optical Fiber-Based Sensors for Nuclear Microreactor Structural Health Monitoring

This report provides an experimental assessment of two different optical fiber–based acoustic sensors that are being investigated for application in nuclear microreactors to enhance structural health monitoring capabilities. Optical fibers are resilient in high-temperature and high-radiation environments, have a small sensor footprint, are immune to electromagnetic interference, and are capable of spatially distributed sensing. The two sensors investigated here are (1) Fabry–Pérot Cavities (FPCs) between two copper-coated fibers, embedded in nickel capillary tubes and (2) type-I fiber Bragg grating (FBG) arrays contained within metal capillary tubes. These sensors can be interrogated using low-coherence interferometry or swept wavelength interferometry, respectively, to measure the resonant frequencies of the components or systems to which these sensors are bonded. The FPC developed herein has been subjected to temperatures up to nearly 800°C while tack-welded to a tubular test specimen. Even at the highest temperatures, the measured resonant frequencies compared well with those obtained using an accelerometer that was bonded to an unheated portion of the specimen. The FBG array was tested in multiple bonding configurations to a tubular test specimen, all at room temperature, with the understanding that high temperature (i.e., type II) FBGs could be used to obtain similar data at high temperatures; the FBG array data were validated with noncontact laser vibrometry, which is being used at Los Alamos National Laboratory to relate acoustic signatures to component stresses and/or structural defects. The goal of this work is to identify the most promising techniques that are also compatible with operation in a microreactor environment.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Design of ePixM, a fully-depleted monolithic CMOS active pixel sensor for soft X-ray experiments at LCLS-II

The LCLS-II Free Electron Laser (FEL) will produce X-ray pulses with a repetition rate of up to 1 MHz and energies between 250 eV and 5 keV. Experiments conducted at LCLS-II will require 2D imaging detectors with a unique set of features, such as high-spatial resolution, low-noise performance, high-dynamic range and high-frame rates up to 1 MHz. We present the design of ePixM, a fully-depleted monolithic CMOS detector tailored for soft X-rays applications at high-repetition rates FEL. It consists of an array of 384×192 active pixel sensors, with a pixel size of 50×50 μm 2 and a total sensitive area of 2×1 cm 2 . ePixM has been designed in a 150 nm CMOS technology on high-resistivity substrate to achieve full depletion of the substrate. Each pixel includes a Charge Sensitive Amplifier (CSA) with gain auto-ranging capability and a noise-shaper performing Correlated Double Sampling (CDS). A novel technique named correlated pre-charging removes the excess noise introduced by the gain-switching mechanism. The performance of the design has been evaluated through post-layout simulations. The Equivalent Noise Charge (ENC) of 11.3 electrons enables single-photon detection at X-ray energies down to 250 eV, and the dynamic range exceeds 10 3 photons at 500 eV thanks to the auto-ranging circuitry.

47 OTHER INSTRUMENTATION↗

Modulation and Modeling of Three-Dimensional Nanowire Assemblies Targeting Gas Sensors with High Response and Reliability

Despite improved sensitivity, simple downsizing of gas-sensing components to randomly arranged nanostructures often faces challenges associated with unpredictable electrical conduction pathways. In the present study, controlled fabrication of three-dimensional (3D) metal oxide nanowire networks is demonstrated that can greatly improve both signal stability and sensor response compared to random nanowire arrays. For example, the highest ever reported H 2 S gas response value, and a 5 times lower relative standard deviation of baseline resistance than that of random nanowires assemblies, are achieved with the ordered 3D nanowire network. Systematic engineering of 3D geometries and their modeling, utilizing equivalent circuit components, provide additional insights into the electrical conduction and gas-sensing response of 3D assemblies, revealing the critical importance of wire-to-wire junction points and their arrangement. Here these findings suggest new design rules for both enhanced performance and reliability of chemical sensors, which may also be extended to other devices based on nanoscale building blocks.

36 MATERIALS SCIENCE↗

The Simons Observatory Microwave SQUID Multiplexing Detector Module Design

Advances in cosmic microwave background (CMB) science depend on increasing the number of sensitive detectors observing the sky. New instruments deploy large arrays of superconducting transition-edge sensor (TES) bolometers tiled densely into ever larger focal planes. High multiplexing factors reduce the thermal loading on the cryogenic receivers and simplify their design. We present the design of focal-plane modules with an order of magnitude higher multiplexing factor than has previously been achieved with TES bolometers. We focus on the novel cold readout component, which employs microwave SQUID multiplexing (μmux). Simons Observatory will use 49 modules containing 70,000 bolometers to make exquisitely sensitive measurements of the CMB. We validate the focal-plane module design, presenting measurements of the readout component with and without a prototype detector array of 1728 polarization-sensitive bolometers coupled to feedhorns. The readout component achieves a 95% yield and a 910 multiplexing factor. The median white noise of each readout channel is 65 . This impacts the projected SO mapping speed by <8%, which is less than is assumed in the sensitivity projections. The results validate the full functionality of the module. We discuss the measured performance in the context of SO science requirements, which are exceeded.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Lens-free compound eye cameras based on angle-sensitive meta-surfaces

A lens-free ultrathin imaging sensor using a compound-eye vision modality can be formed by forming a metasurface on each pixel of an array of pixels in a solid state imaging sensor. The metasurface can be configured to form a diffraction grating that directs light incident on the metasurface at a predefined angle to excite surface plasmon polaritons into the solid state imaging sensor and light incident at any other angle is reflected or diffracted away from the metasurface. Each pixel of the imaging sensor can be configured using the metasurface to only receive light incident from a different portion of a field of view. A computational imaging system can be used to construct the image from the individual pixels.

Paiella, Roberto↗

Advanced Energy Scale Correction Techniques for the X-ray Transition Edge Sensors of the Athena mission

The X-ray Integral Field Unit (X-IFU) onboard the future European X-ray telescope Athena will be the first space instrument carrying an array of more than a thousand transition edge sensors. One of the key challenges of the X-IFU is the measurement of narrow X-ray atomic lines to determine velocity shifts at an unprecedented level of accuracy. For this reason, the energy scale of the instrument needs to be known with extreme accuracy, of 0.4 eV (1σ) up to 7 keV. The energy scale will be measured on the ground through a dedicated calibration campaign using fiducial X-ray sources. Though calibrated, the energy scale is extremely sensitive to the environmental conditions around the TES array, and drifts in the readout chain electronics. Uncorrected, the energy scale can naturally drift up to hundreds of eVs. Changes of the TES gain will be monitored via onboard X-ray calibration sources, and the energy scale will be corrected either per pixel, or within a small groups of pixels. Although simulations show that a 0.4 eV level can be achieved, the very high accuracy required by the X-IFU calls for experimental validation. A dedicated measurement campaign has been performed by NASA Goddard Space Flight Center to characterize the energy scale of a prototype kilo-pixel array of X-IFU-representative TESs. The analysis of the data demonstrated the ability to correct for various drifts using two fiducial lines to track the temporal gain variation. In this paper, we propose to extend this study on the same data set by investigating multi-parameter correction techniques based on both the pulse-height of the fiducial line and the prepulse baseline level, using the knowledge of the TES energy scale at reference temperature/magnetic field set points acquired on the ground. Investigations on the co-adding of pixels to perform a joint correction over pools of pixels is also explored.

79 ASTRONOMY AND ASTROPHYSICS↗

FiberFlex: Real-time FPGA-based Intelligent and Distributed Fiber Sensor System for Pedestrian Recognition

In recent years, security monitoring of public places and critical infrastructure has heavily relied on the widespread use of cameras, raising concerns about personal privacy violations. To balance the need for effective security monitoring with the protection of personal privacy, we explore the potential of optical fiber sensors for this application. This article proposes FiberFlex, an intelligent and distributed fiber sensor system. Ultizing Field Programmable Gate Arrays (FPGA) high-level synthesis (HLS) acceleration, FiberFlex offers real-time pedestrian detection by co-designing the entire pipeline of optical signal acquisition, processing, and recognition networks based on the principles of optical fiber sensing. As a promising alternative to traditional camera-based monitoring systems, FiberFlex achieves pedestrian detection by analyzing the vibration patterns caused by pedestrian footsteps, enabling security monitoring while preserving individual privacy. FiberFlex comprises three modules: First , fiber-optic sensing system: A fiber-optic distributed acoustic sensing (DAS) system is built and used to measure the ground vibration waves generated by people walking. Second , algorithms: We first collect the training data by measuring the ground vibration waves, label the data, and use the data to train the neural network models to perform pedestrian recognition. Third , hardware accelerators: We use HLS tools to design hardware modules on FPGA for data collection and pre-processing and integrate them with the downstream neural network accelerators to perform in-line real-time pedestrian detection. The final detection results are sent back from FPGA to the host CPU. We implement our system FiberFlex with the in-house built DAS system and AMD/Xilinx Kintex7 FPGA KC705 board and verify the whole system using the real-world collected data. We conduct recognition tests on five test subjects of varying ages, heights, and weights in a fixed sensing area. Each subject experienced 20 real-time recognition tests using their daily walking habits, and the subjects were given adequate rest between tests. After 100 tests on five test subjects, the overall real-time recognition accuracy exceeded \(88.0\%\) . The whole system uses 55 W of power, 33 W in the optical DAS system and 22 W in the FPGA. Relying on its end-to-end interdisciplinary design, FiberFlex seamlessly combines fiber-optic sensors with FPGA accelerators to enable low-power real-time security monitoring without compromising privacy, making it a valuable addition to the existing security monitoring network. According to FiberFlex, more valuable research can be conducted in the future, such as fall monitoring for the elderly, migration of identification networks between different application scenarios, and improvement of anti-interference performance in more complex environments. In future perception networks, where the “eyes” are not feasible, let’s use fiber optic touch instead.

Distributed↗

Josephson Effects in Frequency-Domain Multiplexed TES Microcalorimeters and Bolometers

Frequency-division multiplexing is the baseline read-out system for large arrays of superconducting transition-edge sensors (TES’s) under development for the X-ray and infrared instruments like X-IFU (Athena) and SAFARI, respectively. In this multiplexing scheme, the sensors are ac-biased at different frequencies from 1 to 5 MHz and operate as amplitude modulators. Weak superconductivity is responsible for the complex TES resistive transition, experimentally explored in great detail so far, both with dc- and ac-biased read-out schemes. In this paper, we will review the current status of our understanding of the physics of the TES’s and their interaction with the ac bias circuit. In particular, we will compare the behaviour of the TES nonlinear impedance, across the superconducting transition, for several detector families, namely: high-normal-resistance TiAu TES bolometers, low-normal-resistance MoAu TES microcalorimeters and high-normal-resistance TiAu TES microcalorimeters.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A microwave SQUID multiplexer optimized for bolometric applications

A microwave SQUID (superconducting quantum interference device) has been optimized for reading out large arrays of superconducting transition-edge sensor (TES) bolometers. We present the scalable cryogenic multiplexer chip design that may be used to construct an 1820-channel multiplexer for the 4-8 GHz rf band. The key metrics of yield, sensitivity, and crosstalk are determined through measurements of 455 readout channels, which span 4-5 GHz. The median white-noise level is 45 pA/ $\sqrt{Hz}$, evaluated at 2 Hz, with a 1/f knee ≤ 20 mHz after common-mode subtraction. The white-noise level decreases the sensitivity of a TES bolometer optimized for detection of the cosmic microwave background at 150 GHz by only 3%. The measured crosstalk between any channel pair is ≤ 0.3%.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Infrasound direction of arrival determination using a balloon-borne aeroseismometer

Free-floating balloons are an emerging platform for infrasound recording, but they cannot host arrays sufficiently wide for multi-sensor acoustic direction finding techniques. Because infrasound waves are longitudinal, the balloon motion in response to acoustic loading can be used to determine the signal azimuth. This technique, called “aeroseismometry,” permits sparse balloon-borne networks to geolocate acoustic sources. This is demonstrated by using an aeroseismometer on a stratospheric balloon to measure the direction of arrival of acoustic waves from successive ground chemical explosions. A geolocation algorithm adapted from hydroacoustics is then used to calculate the location of the explosions.

47 OTHER INSTRUMENTATION↗

Observations of Stably Stratified Flow through a Microscale Gap

This paper reports the findings of a comprehensive field investigation on flow through a mountain gap subject to a range of stably stratified environmental conditions. This study was embedded within the Perdigão field campaign, which was conducted in a region of parallel double-ridge topography with ridge-normal wind climatology. One of the ridges has a well-defined gap (col) at the top, and an array of in situ and remote sensors, including a novel triple Doppler lidar system, was deployed around it. The experimental design was mostly guided by previous numerical and theoretical studies conducted with an idealized configuration where a flow (with characteristic velocity U 0 and buoyancy frequency N ) approaches normal to a mountain of height h with a gap at its crest, for which the governing parameters are the dimensionless mountain height G= (Nh)/U 0 and various gap aspect ratios. Modified forms of G were proposed to account for real-world atmospheric variability, and the results are presented in terms of a gap-averaged value G c . The nature of gap flow was highly dependent on G c , wherein a nearly neutral flow regime (G c <1), a transitional mountain wave regime (G c ~O(1)), and a gap-jetting regime ( G c >O(1)) were identified. The measurements were in broad agreement with previous numerical and theoretical studies on a single ridge with a gap or double ridge topography, although details vary. This is the first ever detailed field study reported on microscale (O(100 m)) gap flows, and provides useful data and insights for future theoretical and numerical studies.

Microscale, Gap, environmental fluid dynamics, win↗

Single-shot picosecond pump coherent Rayleigh scattering thermometry

A single-shot coherent Rayleigh scattering (CRS) technique capable of measurement times less than 10 ns is presented. Here, the use of a mode-locked picosecond pump laser yields repeatable electrostrictive forcing compared to previous CRS experiments using unseeded nanosecond pump pulses, which are beset by shot-to-shot variations. Quantitative measurements are achieved by dispersing the CRS signal onto an EMCCD sensor using a virtually imaged phased array and comparing the experimental spectra to an existing kinetic model with a least-squares fitting routine. Measurements are demonstrated at ambient and low-pressure (2 Torr), low-temperature (100 K) conditions where the CRS measurement is within the collisionless regime. Single-shot statistics indicated precision and accuracy within 4% at ambient conditions and within 8% at low density and temperature conditions. This single-shot CRS technique is a powerful diagnostic tool with potential for multi-parameter measurements in complex flow environments, including high-speed aerodynamic ground test facilities.

Senior, William Charles Bowman [Sandia National La↗

Rapidly Deployable Acoustic Monitoring and Localization System Based on a Low-Cost Wave Buoy Platform

The primary objective of this project is to develop a cost-effective, fit-for-purpose environmental monitoring system, “NoiseSpotter®,” that characterizes, classifies, and provides accurate location information for anthropogenic and natural sounds in near real-time. NoiseSpotter was developed to support the evaluation of potential acoustic effects of marine energy (ME) projects. By utilizing a compact array of three acoustic particle motion sensors, NoiseSpotter triangulates individual bearings to provide sound source localization to within 5% accuracy, allowing the ability to discern ME device sounds relative to other confounding sounds in the environment, while providing location estimates to nearby marine mammals for environmental mitigation purposes. The ME industry needs proven solutions to meet environmental impact assessment needs. The NoiseSpotter® includes off-the-shelf, modular components that are easy to assemble and disassemble. Its acoustic particle motion sensors are commercially available and the data logger and real-time telemetry system is designed to be plug-and-play. The entire system is relatively compact and can be deployed from small vessels. NoiseSpotter’s near real-time capability enables operational monitoring of ME sounds, particularly during early stages of technology adoption to facilitate mitigation of potential noise effects. Widespread adoption of the technology for acoustic monitoring of ME devices requires that it be cost effective; hence the anticipated commercial cost of system hardware is $35,000. This project contributes to reducing barriers to ME testing through support of scientific research focused on reducing or mitigating environmental risks and lowering costs and complexity of environmental monitoring. This project has developed an acoustic monitoring system, NoiseSpotter® (U.S. Patent No. 11,156,734 and U.S. Registered Trademark No. 6,442,313), to detect and characterize baseline noise and sounds from ME operations and support geolocation of detected sounds. The intended outcome of the project is to mitigate concerns about the potential for ME device noise to alter marine mammal or fish behavior. NoiseSpotter® enables cost-effective, near real-time acoustic monitoring of an operational ME device relative to ambient environmental noise and provides a technical basis for ME developers seeking to navigate the permitting process in an efficient manner.

16 TIDAL AND WAVE POWER↗

Block Island Environmental Monitoring Data (Weather, Waves & Sensor Depth)

This dataset contains meteorological, oceanographic, and sensor-depth data collected near Block Island during the 2016 and 2017 RODEO field seasons to provide environmental context for concurrent acoustic and survey operations. It includes buoy-derived wind and wave time series, in-situ water temperature logger records, and depth (pressure) records from a sensor mounted on the vertical line array.

17 WIND ENERGY↗

Seismoacoustic Signatures Observed During a Long-Term Deployment of Infrasound Sensors at the Nevada National Security Site

Earthquakes have repeatedly been shown to produce inaudible acoustic signals (<20 Hz), otherwise known as infrasound. These signals can propagate hundreds to thousands of kilometers and still be detected by ground-based infrasound arrays depending on the source strength, distance between source and receiver, and atmospheric conditions. Another type of signal arrival at infrasound arrays is the seismic induced motion of the sensor itself, or ground-motion-induced sensor noise. Measured acoustic and seismic waves produced by earthquakes can provide insight into properties of the earthquake such as magnitude, depth, and focal mechanism, as well as information about the local lithology and atmospheric conditions. Large earthquakes that produce strong acoustic signals detected at distances greater than 100 km are the most commonly studied; however, more recent studies have found that smaller magnitude earthquakes ($M$ w <2.0) can be detected at short ranges. In that vein, this study will investigate the ability for a long-term deployment of infrasound sensors (deployed as part of the Source Physics Experiments [SPE] from 2014 to 2020) to detect both seismic and infrasonic signals from earthquakes at local ranges (<50 km). Methods used include a combination of spectral analysis and automated array processing, supported by U.S. Geological Survey earthquake bulletins. Further, this investigation revealed no clear acoustic detections for short range earthquakes. However, secondary infrasound from an $M$ w 7.1 earthquake over 200 km away was detected. Important insights were also made regarding the performance of the SPE networks including detections of other acoustic sources such as bolides and rocket launches. Finally, evaluation of the infrasound arrays is performed to provide insight into optimal deployments for targeting earthquake infrasound.

58 GEOSCIENCES↗

Hammerhead, an ultrahigh resolution ePix camera for wavelength-dispersive spectrometers

Wavelength-dispersive spectrometers (WDS) are often used in synchrotron and FEL applications where high energy resolution (in the order of eV) is important. Increasing WDS energy resolution requires increasing spatial resolution of the detectors in the dispersion direction. The common approaches are not ideal: using strip detectors loses the 2D position sensitivity (important for, e.g., background estimation) and the high counting rate; using pixel detectors with a small pitch results in complex charge sharing behaviour and typically have a small size. Developing pixel detectors with high aspect ratio and a small pitch in the wavelength dispersive direction would be ideal, however, it would require a substantial ASIC development. We present a new approach, with a novel sensor design using rectangular pixels with a high aspect ratio (between strips and pixels, further called “strixels”), and strixel redistribution to match the square pixel arrays of typical ASICs. This results in a sensor area of 17.4 mm × 77 mm, with a fine pitch of 25 µm in the horizontal direction resulting in 3072 columns and 176 rows. The sensors use ePix100 readout ASICs, leveraging their low noise (43 e - , or 180 eV rms). We present results obtained with a Hammerhead ePix100 camera, showing that the small pitch (25 µm) in the dispersion direction maximizes performance for both high and low photon occupancies, resulting in optimal WDS energy resolution. The low noise level at high photon occupancy allows precise photon counting, while at low occupancy, both the energy and the subpixel position can be reconstructed for every photon, allowing an ultrahigh resolution (in the order of 1 µm) in the dispersion direction and rejection of scattered beam and harmonics. Using strixel sensors with redistribution and flip-chip bonding to standard ePix readout ASICs results in ultrahigh position resolution (~1 µm) and low noise in WDS applications, leveraging the advantages of hybrid pixel detectors (high production yield, good availability, relatively inexpensive) while minimizing development complexity through sharing the ASIC, hardware, software and DAQ development with other versions of ePix cameras.

47 OTHER INSTRUMENTATION↗

High Yield Xray Imager Final Design Review

The High Yield Xray Imager (HYXI) is a new NIF target diagnostic system currently under development. The goal of HYXI is to provide high-fidelity, high temporal resolution x-ray imaging capability on high yield NIF implosions at 10MJ and above. The HYXI instrument design concept is based on the combination of two technologies that have been successfully utilized at the NIF on previous instruments, electron pulse-dilation and hybrid-CMOS sensor imaging. The combination of these two techniques will give HYXI sufficient data quality to ascertain differences in hot spot formation dynamics between high and low yield implosions. This information will highlight the critical hot spot conditions needed for ignition and burn. The HYXI design leverages the successful operation of the PDIXI x-ray imager at the NIF on multi MJ yield shots. A new radiation tolerant CMOS imaging array (HYPERION) is being developed to eliminate the significant background noise which limits the data quality of PDIXI. We successfully placed the contract with Advanced hCMOS Systems (AHS) to develop the HYPERION sensor, which fulfils our criteria to place long lead time item procurements by end of FY24. The HYXI Final Design Review was completed at the end of Q4 FY24 (Sep 24 th and Sep 30 th ). The HYXI project is a multi-year effort with a phased approach to be bring up system functionality over time in parallel with the development and fabrication effort of the HYPERION CMOS imaging array. In Phase 1, time-integrated x-ray images on NIF DT experiments will be collected starting in Q3 FY25. In Phase 2 of the project, time-resolved imaging with HYXI utilizing a spare microchannel plate detector back-end will begin in Q3 FY26. Phase 3 concludes the project with the installation of the HYPERION sensor array and the final performance qualification of the HYXI instrument which is scheduled for Q3 FY27 as discussed in the PDR and MRT report on this project in FY23.

42 ENGINEERING↗

Modeling Urban Acoustic Noise in the Las Vegas, NV Region

Ambient infrasound noise in quiet, rural environments has been extensively studied and well-characterized through noise models for several decades. More recently, creating noise models for high-noise rural environments has also become an area of active research. However, far less work has been done to create generalized low-frequency noise models for urban areas. The high ambient noise levels expected in cities and other highly populated areas means that these environments are regarded as poor locations for acoustic sensors, and historically, sensor deployment in urban areas were avoided for this reason. However, there are several advantages to placing sensors in urban environments, including convenience of deployment and maintenance, and increasingly, necessity, as more previously rural areas become populated. This study seeks to characterize trends in low-frequency urban noise by creating a background noise model for Las Vegas, NV, using the Las Vegas Infrasound Array (LVIA): a network of eleven infrasound sensors deployed throughout the city. Data included in this study spans from 2019 to 2021 and provides a largely uninterrupted record of noise levels in the city from 0.1–500 Hz, with only minor discontinuities on individual stations. We organize raw data from the LVIA sensors into hourly power spectral density (PSD) averages for each station and select from these PSDs to create frequency distributions for time periods of interest . These frequency distributions are converted into probability density functions (PDFs), which are then used to evaluate variations in frequency and amplitude over daily to seasonal timescale s. In addition to PDFs, the median, 5 th percentile, and 95 th percentile amplitude values are calculated across the entire frequency range. This methodology follows a well-established process for noise model creation.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗