Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “selected inversion”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Reliable fusion of control and sensing in intelligent machines

Although robotics research has produced a wealth of sophisticated control and sensing algorithms, very little research has been aimed at reliably combining these control and sensing strategies so that a specific task can be executed. To improve the reliability of robotic systems, analytic techniques are developed for calculating the probability that a particular combination of control and sensing algorithms will satisfy the required specifications. The probability can then be used to assess the reliability of the design. An entropy formulation is first used to quickly eliminate designs not capable of meeting the specifications. Next, a framework for analyzing reliability based on the first order second moment methods of structural engineering is proposed. To ensure performance over an interval of time, lower bounds on the reliability of meeting a set of quadratic specifications with a Gaussian discrete time invariant control system are derived. A case study analyzing visual positioning in robotic system is considered. The reliability of meeting timing and positioning specifications in the presence of camera pixel truncation, forward and inverse kinematic errors, and Gaussian joint measurement noise is determined. This information is used to select a visual sensing strategy, a kinematic algorithm, and a discrete compensator capable of accomplishing the desired task. Simulation results using PUMA 560 kinematic and dynamic characteristics are presented.

Mcinroy, John E.↗

Implicit and Multigrid Method for Ideal Multigrid Convergence: Direct Numerical Simulation of Separated Flow Around NACA 0012 Airfoil

Numerical investigation of flow separation over a NACA 0012 airfoil at large angles of attack has been carried out. The numerical calculation is performed by solving the full Navier-Stokes equations in generalized curvilinear coordinates. The second-order LU-SGS implicit scheme is applied for time integration. This scheme requires no tridiagonal inversion and is capable of being completely vectorized, provided the corresponding Jacobian matrices are properly selected. A fourth-order centered compact scheme is used for spatial derivatives. In order to reduce numerical oscillation, a sixth-order implicit filter is employed. Non-reflecting boundary conditions are imposed at the far-field and outlet boundaries to avoid possible non-physical wave reflection. Complex flow separation and vortex shedding phenomenon have been observed and discussed.

Liu, Chao-Qun↗

Reduction of Phase Ambiguity in an Offset-QPSK Receiver

Proposed modifications of an offset-quadri-phase-shift keying (offset-QPSK) transmitter and receiver would reduce the amount of signal processing that must be done in the receiver to resolve the QPSK fourfold phase ambiguity. Resolution of the phase ambiguity is necessary in order to synchronize, with the received carrier signal, the signal generated by a local oscillator in a carrier-tracking loop in the receiver. Without resolution of the fourfold phase ambiguity, the loop could lock to any of four possible phase points, only one of which has the proper phase relationship with the carrier. The proposal applies, more specifically, to an offset-QPSK receiver that contains a carrier-tracking loop like that shown in Figure 1. This carrier-tracking loop does not resolve or reduce the phase ambiguity. A carrier-tracking loop of a different design optimized for the reception of offset QPSK could reduce the phase ambiguity from fourfold to twofold, but would be more complex. Alternatively, one could resolve the fourfold phase ambiguity by use of differential coding in the transmitter, at a cost of reduced power efficiency. The proposed modifications would make it possible to reduce the fourfold phase ambiguity to twofold, with no loss in power efficiency and only relatively simple additional signal-processing steps in the transmitter and receiver. The twofold phase ambiguity would then be resolved by use of a unique synchronization word, as is commonly done in binary phase-shift keying (BPSK). Although the mathematical and signal-processing principles underlying the modifications are too complex to explain in detail here, the modifications themselves would be relatively simple and are best described with the help of simple block diagrams (see Figure 2). In the transmitter, one would add a unit that would periodically invert bits going into the QPSK modulator; in the receiver, one would add a unit that would effect different but corresponding inversions of bits coming out of the QPSK demodulator. The net effect of all the inversions would be that depending on which lock point the carrier-tracking loop had selected, all the output bits would be either inverted or non-inverted together; hence, the ambiguity would be reduced from fourfold to twofold, as desired.

Berner, Jeff↗

Optimal Control Prediction Method for Control Allocation

This paper proposes a novel prediction method for online optimal control allocation that extends the volume of moments achievable with the Moore-Penrose generalized inverse to the entire Attainable Moment Set. This method formulates the control allocation problem using selected basis vectors and associated gains which reduces the optimization problem dimensions and provides physical insight into the resulting optimal solutions. The proposed algorithm finds the entire family of unique optimal control solutions along the desired moment vector from the origin to the boundary of the Attainable Moment Set. Numerical results for the Moore-Penrose prediction method show that the unique minimal controls obtained yield the desired moment with near machine precision accuracy while maintaining control effectors within specified position limits. This method has been fully validated against the unique solution obtained on the boundary of the Attainable Moment Set using the Durham Direct Allocation method. Minimal control solutions obtained for moments in the interior of the Attainable Moment Set, similarly yield the desired moment to near machine precision while providing control solutions that are smaller (i.e. 2-norm) than solutions found with traditional control allocation algorithms (e.g. interior point methods) applied to the minimal control problem. Numerical simulations using a Matlab® autocoded executable (MEX) for the representative real world problem of 3-moments with 20 individual control effectors and prescribed control position limits show a mean computation speed of approximately 125 Hz which is sufficient to enable real-time flight allocation.

Acheson, Michael J.↗

Simulation of Ground Winds Time Series for the NASA Crew Launch Vehicle (CLV)

Simulation of wind time series based on power spectrum density (PSD) and spectral coherence models for ground wind turbulence is described. The wind models, originally developed for the Shuttle program, are based on wind measurements at the NASA 150-m meteorological tower at Cape Canaveral, FL. The current application is for the design and/or protection of the CLV from wind effects during on-pad exposure during periods from as long as days prior to launch, to seconds or minutes just prior to launch and seconds after launch. The evaluation of vehicle response to wind will influence the design and operation of constraint systems for support of the on-pad vehicle. Longitudinal and lateral wind component time series are simulated at critical vehicle locations. The PSD model for wind turbulence is a function of mean wind speed, elevation and temporal frequency. Integration of the PSD equation over a selected frequency range yields the variance of the time series to be simulated. The square root of the PSD defines a low-pass filter that is applied to adjust the components of the Fast Fourier Transform (FFT) of Gaussian white noise. The first simulated time series near the top of the launch vehicle is the inverse transform of the adjusted FFT. Simulation of the wind component time series at the nearest adjacent location (and all other succeeding next nearest locations) is based on a model for the coherence between winds at two locations as a function of frequency and separation distance, where the adjacent locations are separated vertically and/or horizontally. The coherence function is used to calculate a coherence weighted FFT of the wind at the next nearest location, given the FFT of the simulated time series at the previous location and the essentially incoherent FFT of the wind at the selected location derived a priori from the PSD model. The simulated time series at each adjacent location is the inverse Fourier transform of the coherence weighted FFT. For a selected design case, the equations, the process and the simulated time series at multiple vehicle stations are presented.

Adelfang, Stanley I.↗

Size resolved particle volatility for 30, 60, and 90 nm particles collected at the EPCAPE Mount Soledad site from 04/23/2023 to 06/15/2023

VTDMA GF-PDF: Growth factor probability density functions from the Gysel inversion are located here, where probability is out of 200. The instrument measured three different diameters 30 nm, 60nm and 90nm each diameter was selected for an hour. During that hour three different temperatures where scanned (40°C, 80°C, 160°C) in between each temperature a bypass scan was taken at room temperature. Each scan took 10-minutes and scanned growth factors from 0.2-1.2. Calibrations of the instrument with NaCl were performed on 4/26/2023 from 11:20 to 14:20, on 5/16/2023 from 11:40 to 16:00, and on 5/30/2023 from 10:20 to 14:20. Calibrations with (NH4)2SO4 were performed on 5/8/2023 from 11:45 to 14:40, on 5/23/2023 from 11:20 to 3:00, and on 6/14/2023 from 13:00 to 16:00. Time is recorded in seconds since 1/1/1904. GF_Vol_avg: Growth factor volume average calculated by the Gysel inversion. The instrument measured three different diameters 30 nm, 60nm and 90nm each diameter was selected for an hour. During that hour three different temperatures where scanned (40°C, 80°C, 160°C) in between each temperature a bypass scan was taken at room temperature. Each scan took 10-minutes and scanned growth factors from 0.2-1.2. Calibrations of the instrument with NaCl were performed on 4/26/2023 from 11:20 to 14:20, on 5/16/2023 from 11:40 to 16:00, and on 5/30/2023 from 10:20 to 14:20. Calibrations with (NH4)2SO4 were performed on 5/8/2023 from 11:45 to 14:40, on 5/23/2023 from 11:20 to 3:00, and on 6/14/2023 from 13:00 to 16:00. Time is recorded in seconds since 1/1/1904.

30nm growth factor volume average at 160C (GF_vol_↗

Surfactant selection as a strategy for tailoring the structure and properties of UCT manganese oxides

Mesoporous manganese oxides were synthesized using the UCT inverse micelle templating method with four different Pluronic surfactants to investigate the effects on the morphology, microstructure and desulfurization behavior of these materials. All of the as-synthesized samples exhibited similar hierarchical microstructures, but the size and shape of the primary nanoparticles for each sample was different. The primary nanoparticle sizes for these samples vary between 2.3 and 7.0 nm. Most of the samples are crystalline and are composed of a mixture of Mn 3 O 4 and Mn 5 O 8 phases. The adsorption behavior of these samples was tested using a fixed bed reactor at a temperature of 200 °C. Microstructural analysis of the samples after the desulfurization tests revealed a transformation of the mesoporous manganese oxide to a dense manganese sulfide phase; this involves a volumetric expansion of the crystal, leading to densification and a rapid decay in the sorption capacity after the breakthrough point. The variation in the structure and properties of these materials is related to ratio of the PEO and PPO chain segment lengths in the Pluronic surfactants used. This indicates that the ratio must dictate the volume, shape and assembly of the inverse micelles in the UCT synthesis.

36 MATERIALS SCIENCE↗

On the dosimetric effect and reduction of inverse consistency and transitivity errors in deformable image registration for dose accumulation

Purpose: Deformable image registration (DIR) is necessary for accurate dose accumulation between multiple radiotherapy image sets. DIR algorithms can suffer from inverse and transitivity inconsistencies. When using deformation vector fields (DVFs) that exhibit inverse-inconsistency and are nontransitive, dose accumulation on a given image set via different image pathways will lead to different accumulated doses. The purpose of this study was to investigate the dosimetric effect of and propose a postprocessing solution to reduce inverse consistency and transitivity errors. Methods: Four MVCT images and four phases of a lung 4DCT, each with an associated calculated dose, were selected for analysis. DVFs between all four images in each data set were created using the Fast Symmetric Demons algorithm. Dose was accumulated on the fourth image in each set using DIR via two different image pathways. The two accumulated doses on the fourth image were compared. The inverse consistency and transitivity errors in the DVFs were then reduced. The dose accumulation was repeated using the processed DVFs, the results of which were compared with the accumulated dose from the original DVFs. To evaluate the influence of the postprocessing technique on DVF accuracy, the original and processed DVF accuracy was evaluated on the lung 4DCT data on which anatomical landmarks had been identified by an expert. Results: Dose accumulation to the same image via different image pathways resulted in two different accumulated dose results. After the inverse consistency errors were reduced, the difference between the accumulated doses diminished. The difference was further reduced after reducing the transitivity errors. The postprocessing technique had minimal effect on the accuracy of the DVF for the lung 4DCT images. Conclusions: This study shows that inverse consistency and transitivity errors in DIR have a significant dosimetric effect in dose accumulation; Depending on the image pathway taken to accumulate the dose, different results may be obtained. A postprocessing technique that reduces inverse consistency and transitivity error is presented, which allows for consistent dose accumulation regardless of the image pathway followed.

61 RADIATION PROTECTION AND DOSIMETRY↗

Analysis-Software for Hyperspectral Algal Reflectance Probes v. 1.0

This software provides onsite analysis of the hyperspectral reflectance data acquired on an outdoor algal pond by a multichannel, fiber-coupled spectroradiometer. The analysis algorithm is based on numerical inversion of a reflectance model, in which the above-water reflectance is expressed as a function of the single backscattering albedo, which is dependent on the backscatter and absorption coefficients of the algal culture, which are in turn related to the algal biomass and pigment optical activity, respectively. Prior to the development of this software, while raw multichannel data were displayed in real time, analysis required a post-processing procedure to extract the relevant parameters. This software provides the capability to track the temporal variation of such culture parameters in real time, as raw data are being acquired, or can be run in a post processing mode. The software allows the user to select between different algal species, incorporate the appropriate calibration data, and observe the quality of the resulting model inversions.

Timlin, Jerilyn A.↗

Microstructure selection in thin-sample directional solidification of an Al-Cu alloy: In situ X-ray imaging and phase-field simulations

We study microstructure selection during directional solidification of a thin metallic sample. We combine in situ X-ray radiography of a dilute Al-Cu alloy solidification experiments with three-dimensional phase-field simulations. We explore a range of temperature gradient G and growth velocity V and build a microstructure selection map for this alloy. We investigate the selection of the primary dendritic spacing Lambda and tip radius rho. While rho shows a good agreement between experimental measurements and dendrite growth theory, with rho similar to V-1/2, Lambda is observed to increase with V (partial derivative Lambda/partial derivative V > 0), in apparent disagreement with classical scaling laws for primary dendritic spacing, which predict that partial derivative Lambda/partial derivative V <0. We show through simulations that this trend inversion for Lambda(V) is due to liquid convection in our experiments, despite the thin sample configuration. We use a classical diffusion boundary-layer approximation to semi-quantitatively incorporate the effect of liquid convection into phase-field simulations. This approximation is implemented by assuming complete solute mixing outside a purely diffusive zone of constant thickness that surrounds the solid-liquid interface. This simple method enables us to quantitatively match experimental measurements of the planar morphological instability threshold and primary spacings over an order of magnitude in V. We explain the observed inversion of partial derivative Lambda/partial derivative V by a combination of slow transient dynamics of microstructural homogenization and the influence of the sample thickness.

36 MATERIALS SCIENCE↗

Photoluminescence Enhancement through Symmetry Breaking Induced by Defects in Nanocrystals

We present a theoretical model for the effect of symmetry breaking introduced by the doping of semiconductor nanocrystals with Coulomb impurities. The presence of a Coulomb center breaks the nanocrystal symmetry and affects its optical properties through the mixing of the hole spin and parity sublevels, breaking the selection rules responsible for the exciton dark state in undoped nanocrystals. After reviewing the effects on the exciton fine structure and optical selection rules using symmetry theory, we present a perturbative model to quantify the effects. We find that the symmetry breaking proceeds by two mechanisms: First, mixing by even parity terms in the Coulomb multipole expansion results in an exciton fine structure consisting of three optically active doublets which are polarized along x, y, and z axes with a ground optically passive dark exciton state, and second, odd parity terms which break inversion symmetry significantly activate optical transitions which are optically forbidden in the unperturbed nanocrystal due to both spin and parity selection rules. In the case of small sized “quasi-spherical” nanocrystals, the introduction of a single positively charged Coulomb center is shown here to result in significant enhancement of the radiative decay rate at room temperatures by up to a factor of 10.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Adaptive Inverse Control for Rotorcraft Vibration Reduction

This thesis extends the Least Mean Square (LMS) algorithm to solve the mult!ple-input, multiple-output problem of alleviating N/Rev (revolutions per minute by number of blades) helicopter fuselage vibration by means of adaptive inverse control. A frequency domain locally linear model is used to represent the transfer matrix relating the higher harmonic pitch control inputs to the harmonic vibration outputs to be controlled. By using the inverse matrix as the controller gain matrix, an adaptive inverse regulator is formed to alleviate the N/Rev vibration. The stability and rate of convergence properties of the extended LMS algorithm are discussed. It is shown that the stability ranges for the elements of the stability gain matrix are directly related to the eigenvalues of the vibration signal information matrix for the learning phase, but not for the control phase. The overall conclusion is that the LMS adaptive inverse control method can form a robust vibration control system, but will require some tuning of the input sensor gains, the stability gain matrix, and the amount of control relaxation to be used. The learning curve of the controller during the learning phase is shown to be quantitatively close to that predicted by averaging the learning curves of the normal modes. For higher order transfer matrices, a rough estimate of the inverse is needed to start the algorithm efficiently. The simulation results indicate that the factor which most influences LMS adaptive inverse control is the product of the control relaxation and the the stability gain matrix. A small stability gain matrix makes the controller less sensitive to relaxation selection, and permits faster and more stable vibration reduction, than by choosing the stability gain matrix large and the control relaxation term small. It is shown that the best selections of the stability gain matrix elements and the amount of control relaxation is basically a compromise between slow, stable convergence and fast convergence with increased possibility of unstable identification. In the simulation studies, the LMS adaptive inverse control algorithm is shown to be capable of adapting the inverse (controller) matrix to track changes in the flight conditions. The algorithm converges quickly for moderate disturbances, while taking longer for larger disturbances. Perfect knowledge of the inverse matrix is not required for good control of the N/Rev vibration. However it is shown that measurement noise will prevent the LMS adaptive inverse control technique from controlling the vibration, unless the signal averaging method presented is incorporated into the algorithm.

Jacklin, Stephen A.↗

Effects of error covariance structure on estimation of model averaging weights and predictive performance

When conducting model averaging for assessing groundwater conceptual model uncertainty, the averaging weights are often evaluated using model selection criteria such as AIC, AICc, BIC, and KIC (Akaike Information Criterion, Corrected Akaike Information Criterion, Bayesian Information Criterion, and Kashyap Information Criterion, respectively). However, this method often leads to an unrealistic situation in which the best model receives overwhelmingly large averaging weight (close to 100%), which cannot be justified by available data and knowledge. It was found in this study that this problem was caused by using the covariance matrix, CE, of measurement errors for estimating the negative log likelihood function common to all the model selection criteria. This problem can be resolved by using the covariance matrix, Cek, of total errors (including model errors and measurement errors) to account for the correlation between the total errors. An iterative two-stage method was developed in the context of maximum likelihood inverse modeling to iteratively infer the unknown Cek from the residuals during model calibration. The inferred Cek was then used in the evaluation of model selection criteria and model averaging weights. While this method was limited to serial data using time series techniques in this study, it can be extended to spatial data using geostatistical techniques. The method was first evaluated in a synthetic study and then applied to an experimental study, in which alternative surface complexation models were developed to simulate column experiments of uranium reactive transport. It was found that the total errors of the alternative models were temporally correlated due to the model errors. The iterative two-stage method using Cek resolved the problem that the best model receives 100% model averaging weight, and the resulting model averaging weights were supported by the calibration results and physical understanding of the alternative models. Using Cek obtained from the iterative two-stage method also improved predictive performance of the individual models and model averaging in both synthetic and experimental studies.

error correlation↗

Toward 2D and 3D imaging of magnetic nanoparticles using EPR measurements

Purpose: Magnetic nanoparticles (MNPs) are an important asset in many biomedical applications. An effective working of these applications requires an accurate knowledge of the spatial MNP distribution. A promising, noninvasive, and sensitive technique to visualize MNP distributions in vivo is electron paramagnetic resonance (EPR). Currently only 1D MNP distributions can be reconstructed. In this paper, the authors propose extending 1D EPR toward 2D and 3D using computer simulations to allow accurate imaging of MNP distributions. Methods: To find the MNP distribution belonging to EPR measurements, an inverse problem needs to be solved. The solution of this inverse problem highly depends on the stability of the inverse problem. The authors adapt 1D EPR imaging to realize the imaging of multidimensional MNP distributions. Furthermore, the authors introduce partial volume excitation in which only parts of the volume are imaged to increase stability of the inverse solution and to speed up the measurements. The authors simulate EPR measurements of different 2D and 3D MNP distributions and solve the inverse problem. The stability is evaluated by calculating the condition measure and by comparing the actual MNP distribution to the reconstructed MNP distribution. Based on these simulations, the authors define requirements for the EPR system to cope with the added dimensions. Moreover, the authors investigate how EPR measurements should be conducted to improve the stability of the associated inverse problem and to increase reconstruction quality. Results: The approach used in 1D EPR can only be employed for the reconstruction of small volumes in 2D and 3D EPRs due to numerical instability of the inverse solution. The authors performed EPR measurements of increasing cylindrical volumes and evaluated the condition measure. This showed that a reduction of the inherent symmetry in the EPR methodology is necessary. By reducing the symmetry of the EPR setup, quantitative images of larger volumes can be obtained. The authors found that, by selectively exciting parts of the volume, the authors could increase the reconstruction quality even further while reducing the amount of measurements. Additionally, the inverse solution of this activation method degrades slower for increasing volumes. Finally, the methodology was applied to noisy EPR measurements: using the reduced EPR setup’s symmetry and the partial activation method, an increase in reconstruction quality of ≈80% can be seen with a speedup of the measurements with 10%. Conclusions: Applying the aforementioned requirements to the EPR setup and stabilizing the EPR measurements showed a tremendous increase in noise robustness, thereby making EPR a valuable method for quantitative imaging of multidimensional MNP distributions.

60 APPLIED LIFE SCIENCES↗

Inclusive b-jet production in pp collisions at sqrt(s)=7 TeV

The inclusive b-jet production cross section in pp collisions at a center-of-mass energy of 7 TeV is measured using data collected by the CMS experiment at the LHC. The cross section is presented as a function of the jet transverse momentum in the range 18 < pT < 200 GeV for several rapidity intervals. The results are also given as the ratio of the b-jet production cross section to the inclusive jet production cross section. The measurement is performed with two different analyses, which differ in their trigger selection and b-jet identification: a jet analysis that selects events with a b jet using a sample corresponding to an integrated luminosity of 34 inverse picobarns, and a muon analysis requiring a b jet with a muon based on an integrated luminosity of 3 inverse picobarns. In both approaches the b jets are identified by requiring a secondary vertex. The results from the two methods are in agreement with each other and with next-to-leading order calculations, as well as with predictions based on the PYTHIA event generator.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The genome of the naturally evolved obesity-prone Ossabaw miniature pig

The feral pigs of Ossabaw Island (USA) have an outstanding propensity to obesity and develop complete metabolic syndrome (MetS) upon prolonged high energy dieting. We now report the first high quality genome of the Ossabaw pig with Contig N50 of ~6.03 Mb, significantly higher than most other published pig genomes. Genomic comparison to Duroc reveals that variations including SNPs, INDELs and one ~2 Mb inversion identified in Ossabaw pig may be related to its “thrifty” phenotype. Finally, an important positively selected gene (PSG) was found to be LEPR (leptin receptor) containing two positively selected sites which may lead to pseudogenization of this gene with possible significant effects on obesity and inflammation development. This work provides the first complete mapping of a genome representing a naturally ‘feast and famine’ evolved phenotype of MetS, serving as a blueprint to guide the search for new targets and new biomarkers for obesity comorbidities.

59 BASIC BIOLOGICAL SCIENCES↗

Application of resistivity monitoring to evaluate cement grouting effect in earth filled dam

In this paper, we applied electrical resistivity monitoring method to evaluate the cement grouting effect. There are a lot of ways to evaluate cement grouting effect. In order to do this evaluation in a great safety, high efficiency, and lower cost, resistivity monitoring is found to be the most appropriate technique. In this paper we have selected a dam site from Korea to acquire resistivity monitoring data and compare the results of inversion to estimate the cement grouting effect.

36 MATERIALS SCIENCE↗

A study of IMRT planning parameters on planning efficiency, delivery efficiency, and plan quality

Purpose: To improve planning and delivery efficiency of head and neck IMRT without compromising planning quality through the evaluation of inverse planning parameters.Methods: Eleven head and neck patients with pre-existing IMRT treatment plans were selected for this retrospective study. The Pinnacle treatment planning system (TPS) was used to compute new treatment plans for each patient by varying the individual or the combined parameters of dose/fluence grid resolution, minimum MU per segment, and minimum segment area. Forty-five plans per patient were generated with the following variations: 4 dose/fluence grid resolution plans, 12 minimum segment area plans, 9 minimum MU plans, and 20 combined minimum segment area/minimum MU plans. Each plan was evaluated and compared to others based on dose volume histograms (DVHs) (i.e., plan quality), planning time, and delivery time. To evaluate delivery efficiency, a model was developed that estimated the delivery time of a treatment plan, and validated through measurements on an Elekta Synergy linear accelerator. Results: The uncertainty (i.e., variation) of the dose-volume index due to dose calculation grid variation was as high as 8.2% (5.5 Gy in absolute dose) for planning target volumes (PTVs) and 13.3% (2.1 Gy in absolute dose) for planning at risk volumes (PRVs). Comparison results of dose distributions indicated that smaller volumes were more susceptible to uncertainties. The grid resolution of a 4 mm dose grid with a 2 mm fluence grid was recommended, since it can reduce the final dose calculation time by 63% compared to the accepted standard (2 mm dose grid with a 2 mm fluence grid resolution) while maintaining a similar level of dose-volume index variation. Threshold values that maintained adequate plan quality (DVH results of the PTVs and PRVs remained satisfied for their dose objectives) were 5 cm{sup 2} for minimum segment area and 5 MU for minimum MU. As the minimum MU parameter was increased, the number of segments and delivery time were decreased. Increasing the minimum segment area parameter decreased the plan MU, but had less of an effect on the number of segments and delivery time. Our delivery time model predicted delivery time to within 1.8%. Conclusions: Increasing the dose grid while maintaining a small fluence grid allows for improved planning efficiency without compromising plan quality. Delivery efficiency can be improved by increasing the minimum MU, but not the minimum segment area. However, increasing the respective minimum MU and/or the minimum segment area to any value greater than 5 MU and 5 cm{sup 2} is not recommended because it degrades plan quality.

62 RADIOLOGY AND NUCLEAR MEDICINE↗