Towards an IPv6-only WLCG: More successes in reducing IPv4

The Worldwide Large Hadron Collider Computing Grid (WLCG) community’s deployment of dual-stack IPv6/IPv4 on its worldwide storage infrastructure has been very successful. Dual-stack is not, however, a viable longterm solution; the HEPiX IPv6 Working Group has focused on studying where and why IPv4 is still being used, and how to flip such traffic to IPv6. The agreed end goal is to turn IPv4 off and run IPv6-only over the wide-area network to simplify both operations and security management.This paper reports our work since the CHEP2023 conference. Firstly, we present our campaign to deploy IPv6 on CPU services and Worker Nodes, with a deadline of end of June 2024. Then, the WLCG Data Challenge (DC24) performed in February 2024 was an excellent opportunity to observe the percentage of data transfers carried by IPv6. We observed the predominance of IPv6 in data transfers during DC24 and were able to understand yet more reasons for the use of IPv4 and areas for remedial action.The paper ends with the working group’s plans for moving WLCG to “IPv6- only”. One aspect of this is the possible automated use of IPv6-only clients configured with a customer-side translator, or CLAT, together with a deployment of NAT64 using what is often known as “IPv6-Mostly”, enabling IPv6-only sites to connect to non-WLCG IPv4-only services.

Attebury, Garhan [U. Nebraska, Lincoln]↗

Spot size measurement of a deuterium–tritium dense plasma focus using neutron radiography

Neutron radiography is a technique uniquely suited to applications in nuclear diagnostics, non-destructive testing, and subcritical experiments. The spatial resolution of neutron radiographs is degraded by optical blur in the imaging system and the neutron source size, where the ideal source is point-like to optimize the point-spread function. A potential neutron source for radiography is the dense plasma focus (DPF), a coaxial Z-pinch that produces thermonuclear and beam-target neutrons. To assess if the source size is suitable for radiography, a neutron imaging system was used to measure the source size of the 4 MA Sodium DPF at the Nevada National Security Site operating with deuterium–tritium gas-fill. The source size was measured using the edge-spread function of tungsten objects, each having a rolled (convex) edge. The spot size was found to be 7–12 mm full-width at half-max (FWHM) assuming a Gaussian source, though comparison is presented for Lorentzian and Bennett distributions. The average FWHM was found to be 8.6 ± 1.2 mm vertically and 10.8 ± 1.2 mm horizontally with respect to the image plane, averaging over varied edges and alignments. The results were sensitive to source alignment and edge metrology, which introduced notable uncertainties. These results are consistent with separate experimental measurements as well as magnetohydrodynamics simulations of this DPF, which suggest that neutron production can originate from pinches ∼5–7 mm off-axis. These results suggest that the DPF should be used for radiography at low magnification (M < 1) where spot size does not dominate spatial blur.

47 OTHER INSTRUMENTATION↗

A graphite oxide (GO)-based remote readable tamper evident seal

Here, this paper presents a prototype of a remotely readable graphite oxide (GO) paper-based tamper evident seal. The proposed device combines the tunable electrical properties offered by reduced graphite oxide (RGO) with a compressive sampling scheme. The benefit of using RGO as a tamper evident seal material is the sensitivity of its electrical properties to the common mechanisms adopted to defeat tamper-evident seals. RGO’s electrical properties vary upon local stress or cracks induced by mechanical action (e.g., produced by shimming or lifting attacks). Further, modification of the seal’s electrical properties can result from the incidence of other defeat mechanisms, such as temperature changes, solvent treatment and steam application. The electrical tunability of RGO enables the engraving of a circuit on the area of the tamper evident seal intended to be exposed to malicious attacks. The operation of the tamper evident seal, as well as its remote communication functionality, is supervised by a microcontroller unit (MCU). The MCU uses the RGO-engraved circuitry to physically implement a compressive sampling acquisition procedure. The compressive sampling scheme provides the seal with self-authentication and self-state-of-health awareness capabilities. Finally, the prototype shows potential for use in low-power, embedded, remote-operation nonproliferation security related applications.

36 MATERIALS SCIENCE↗

PowerModelsGAT-AI: Physics-Informed Graph Attention for Multi-System Power Flow With Continual Learning

Solving the alternating current power flow equations in real time is essential for secure grid operation, yet classical Newton–Raphson solvers can be slow under stressed conditions. Existing graph neural networks for power flow are typically trained on a single system and often degrade on different systems. We present PowerModelsGAT-AI, a physics-informed graph attention network that predicts bus voltages and generator injections. The model uses bus-type-aware masking to handle different bus types and balances multiple loss terms, including a power-mismatch penalty, using learned weights. We evaluate the model on 14 benchmark systems (4 to 6,470 buses) and train a unified model on 13 of these under contingency conditions with up to two branch outages, achieving an average normalized mean absolute error of 0.89% for voltage magnitudes and R 2 >0.99 for voltage angles. We also show continual learning: when adapting a base model to a new 1,354-bus system, standard fine-tuning causes severe forgetting with error increases exceeding 1000% on base systems, while our experience replay and elastic weight consolidation strategy keeps error increases below 2% and in some cases improves base-system performance. Interpretability analysis shows that learned attention weights correlate with physical branch parameters (susceptance: r=0.38 ; thermal limits: r=0.22 ), and feature importance analysis supports that the model captures established power flow relationships.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Neural Lyapunov Control for Power System Transient Stability: A Deep Learning-Based Approach

We report that power system control and transient stability analysis play essential roles in secure system operation. Control of power systems typically involves highly nonlinear and complex dynamics. Most of the existing works address such problems with additional assumptions in system dynamics, leading to a requirement for a complete and general solution. This paper, therefore, proposes a novel control framework for various power system control and stability problems leveraging a learning-based approach. The proposed framework includes a two-module structure that iteratively and jointly learns the candidate Lyapunov function and control law via deep neural networks in a learning module. Meanwhile, it guides the learning procedure towards valid results satisfying Lyapunov conditions in a falsification module. The introduced termination criteria ensure provable system stability. This control framework is verified through several studies handling different types of power system control problems. The results show that the proposed framework is generalizable and can simplify the control design for complex power systems with the stability guarantee and enlarged region of attraction.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Wavelet and Deep-Learning-Based Approach for Generation System Problematic Parameters Identification and Calibration

Accurate models of generation systems are critical for maintaining reliable and secure grid operations. In this paper, a novel and systematic approach is proposed to identify and calibrate the generation system problematic parameters using continuous wavelet transform (CWT) and advanced deep-learning technology. The phasor measurement unit (PMU) data are used through “event playback” to check whether the parameter calibration is required, and if yes, a group of suspicious parameters will be identified as the primary problematic parameter candidates (PPCs). These primary PPCs are randomly perturbed to generate the event playback simulation data, which are used by the CWT and convolutional neural networks (CNNs) to further narrow down the primary PPCs into a smaller set of candidates. Then, the identified candidates are perturbed again to generate massive event playback simulation data for training a parameter calibration neural network. Here, we designed a multi-output neural network structure to find the mappings between the perturbed parameters and the simulation data using both CNN and long short-term memory (LSTM) models. Finally, the well-trained and tested CNN-LSTM model is used to estimate the accurate value of the suspicious parameters with actual PMU measurements. The proposed CNN-LSTM network can accurately and reliably estimate the generation-system problematic parameters, and has better performance when compared to other machine-learning methods, such as the multilayer perceptron network and the conditional variational autoencoder method. The accuracy and effectiveness of the proposed approach have been validated through simulation and real-world data.

24 POWER TRANSMISSION AND DISTRIBUTION↗

LLNL NESHAPs Radionuclide Air Emission Report for 2011 (2011 Annual Report)

Lawrence Livermore National Security, LLC operates facilities at Lawrence Livermore National Laboratory (LLNL) where radionuclides are handled and stored. These facilities are subject to the U.S. Environmental Protection Agency (EPA) National Emission Standards for Hazardous Air Pollutants (NESHAPs) in Code of Federal Regulations (CFR) Title 40, Part 61, Subpart H, which regulates radionuclide emissions to air from Department of Energy (DOE) facilities. Specifically, NESHAPs limits the emission of radionuclides to the ambient air to levels resulting in an annual effective dose equivalent of 10 mrem (100 µSv) to any member of the public. Using measured and calculated emissions, and building-specific and common parameters, LLNL personnel applied the EPA-approved computer code, CAP88-PC, Version 1.0, to calculate the dose to the maximally exposed individual member of the public for the Livermore site and Site 300.

54 ENVIRONMENTAL SCIENCES↗

Combined Heat and Power: Enabling Resilient Energy Infrastructure for Critical Facilities

Critical infrastructure (CI) collectively refers to those assets, systems, and networks that, if incapacitated, would have a substantial negative impact on national or regional security, economic operations, or public health and safety. Combined heat and power (CHP) offers the opportunity to improve CI resiliency, mitigating the impacts of an emergency by keeping critical facilities running without any interruption in electric or thermal service. If the electricity grid is impaired, a specially configured CHP system can continue to operate, ensuring an uninterrupted supply of power and heating or cooling to the host facility.

Hampson, Anne↗

Lawrence Livermore National Laboratory National Emission Standards for Hazardous Air Pollutants (NESHAPs) 2012 Annual Report

Lawrence Livermore National Security, LLC operates facilities at Lawrence Livermore National Laboratory (LLNL) where radionuclides are handled and stored. These facilities are subject to the U.S. Environmental Protection Agency (EPA) National Emission Standards for Hazardous Air Pollutants (NESHAPs) in Code of Federal Regulations (CFR) Title 40, Part 61, Subpart H, which regulates radionuclide emissions to air from Department of Energy (DOE) facilities. Specifically, NESHAPs limits the emission of radionuclides to the ambient air to levels resulting in an annual effective dose equivalent of 10 mrem (100 µSv) to any member of the public. Using measured and calculated emissions, and building-specific and common parameters, LLNL personnel applied the EPA-approved computer code, CAP88-PC, Version 1.0, to calculate the dose to the maximally exposed individual member of the public for the Livermore site and Site 300.

54 ENVIRONMENTAL SCIENCES↗

LLNL NESHAPs 2010 Annual Report

Lawrence Livermore National Security, LLC operates facilities at Lawrence Livermore National Laboratory (INL) where radionuclides are handled and stored. Using measured and calculated emission and building-specific and common parameters, LLNL applied the EPA approved computer code to calculate the dose to the maximally exposed individual for the Livermore site and Site 300.

54 ENVIRONMENTAL SCIENCES↗

LLNL NESHAPs 2009 Annual Report

Lawrence Livermore National Security, LLC operates facilities at Lawrence Livermore National Laboratory (LLNL) where radionuclides are handled and stored. These facilities are subject to the U.S. Environmental Protection Agency (EPA) National Emission Standards for Hazardous Air Pollutants (NESHAPs) in Code of Federal Regulations (CFR) Title 40, Part 61, Subpart H, which regulates radionuclide emissions to air from Department of Energy (DOE) facilities. Specifically, NESHAPs limits the emission of radionuclides to the ambient air to levels resulting in an annual effective dose equivalent of 10 mrem (100 μSv) to any member of the public. Using measured and calculated emissions, and building-specific and common parameters, LLNL personnel applied the EPA-approved computer code, CAP88-PC, Version 1.0, to calculate the dose to the maximally exposed individual for the Livermore site and Site 300. The dose for the LLNL site-wide maximally exposed members of the public from operations in 2009 are summarized here: Livermore site: 0.0042 mrem (0.042 μSv) (36% from point source emissions, 64% from diffuse source emissions). The point source emissions include gaseous tritium modeled as tritiated water vapor as directed by EPA Region IX; the resulting dose is used for compliance purposes; Site 300: 2.7 × 10 -7 mrem (2.7 × 10 -6 μSv) (100% from point source emissions).

54 ENVIRONMENTAL SCIENCES↗

Lawrence Livermore National Laboratory Radionuclide Air Emission Report for 2013 (NESHAPs 2013 Annual Report)

Lawrence Livermore National Security, LLC operates facilities at Lawrence Livermore National Laboratory (LLNL) where radionuclides are handled and stored. These facilities are subject to the U.S. Environmental Protection Agency (EPA) National Emission Standards for Hazardous Air Pollutants (NESHAPs) in Code of Federal Regulations (CFR) Title 40, Part 61, Subpart H, which regulates radionuclide emissions to air from Department of Energy (DOE) facilities. Specifically, NESHAPs limits the emission of radionuclides to the ambient air to levels resulting in an annual effective dose equivalent of 10 mrem (100 μSv) to any member of the public. Using measured and calculated emissions, and building-specific and common parameters, LLNL personnel applied the EPA-approved computer code, CAP88-PC, Version 4.0.0.570, to calculate the dose to the maximally exposed individual member of the public for the Livermore Site and Site 300.

54 ENVIRONMENTAL SCIENCES↗

LLNL NESHAPs 2014 Annual Report

Lawrence Livermore National Security, LLC operates facilities at Lawrence Livermore National Laboratory (LLNL) where radionuclides are handled and stored. These facilities are subject to the U.S. Environmental Protection Agency (EPA) National Emission Standards for Hazardous Air Pollutants (NESHAPs) in Code of Federal Regulations (CFR) Title 40, Part 61, Subpart H, which regulates radionuclide emissions to air from Department of Energy (DOE) facilities. Specifically, NESHAPs limits the emission of radionuclides to the ambient air to levels resulting in an annual effective dose equivalent of 10 mrem (100 μSv) to any member of the public. Using measured and calculated emissions, and building-specific and common parameters, LLNL personnel applied the EPA-approved computer code, CAP88-PC, Version 4.0.1.17, to calculate the dose to the maximally exposed individual member of the public for the Livermore Site and Site 300.

61 RADIATION PROTECTION AND DOSIMETRY↗

LLNL NESHAPs 2015 Annual Report - June 2016

Lawrence Livermore National Security, LLC operates facilities at Lawrence Livermore National Laboratory (LLNL) in which radionuclides are handled and stored. These facilities are subject to the U.S. Environmental Protection Agency (EPA) National Emission Standards for Hazardous Air Pollutants (NESHAPs) in Code of Federal Regulations (CFR) Title 40, Part 61, Subpart H, which regulates radionuclide emissions to air from Department of Energy (DOE) facilities. Specifically, NESHAPs limits the emission of radionuclides to the ambient air to levels resulting in an annual effective dose equivalent of 10 mrem (100 μSv) to any member of the public. Using measured and calculated emissions, and building-specific and common parameters, LLNL personnel applied the EPA-approved computer code, CAP88-PC, Version 4.0.1.17, to calculate the dose to the maximally exposed individual member of the public for the Livermore Site and Site 300.

54 ENVIRONMENTAL SCIENCES↗

General Employee Training Live, Course 15503

This training at Los Alamos National Laboratory contains the following sections: Introduction to the Laboratory, Institutional Quality Assurance, Facilities, Policies, Procedures, and Other Requirements, Safety Expectations, Worker Protection: Occupational Safety and Health, Industrial Hygiene and Safety, Lockout/Tagout, General Employee Radiological Training, Fire Protection, Security, Emergency Operations, Occupational Health, and Environment.

99 GENERAL AND MISCELLANEOUS↗

Protocol for Uniformly Measuring and Expressing the Performance of Energy Storage Systems

This Protocol provides a set of “best practices” for characterizing energy storage systems (ESSs) and measuring and reporting their performance. It serves as a basis for assessing how an ESS will perform with respect to key performance attributes relevant to different applications. It is intended to provide a valid and accurate basis for the comparison of different ESSs. By achieving the stated purpose, the Protocol will enable more informed decision-making in the selection of ESSs for various stationary applications. The Protocol identifies general information and technical specifications relevant in describing an ESS and also defines a set of test, measurement, and evaluation criteria with which to express the performance of ESSs that are intended for energy-intensive and/or power-intensive stationary applications. An ESS includes a storage device, battery management system, and any power conversion systems installed with the storage device. The Protocol is agnostic with respect to the storage technology and the size and rating of the ESS. The Protocol does not apply to single-use storage devices and storage devices that are not coupled with power conversion systems, nor does it address safety, security, or operations and maintenance of ESSs, or provide any pass/fail criteria.

25 ENERGY STORAGE↗

5G Enabled Energy Innovation: Advanced Wireless Networks for Science

Digital wireless communication has become a foundational technology for the nation. The U.S. Department of Energy’s Office of Science (DOE-SC) is the Nation’s largest supporter of basic research in the physical sciences discovering new materials, designing advanced microelectronics, and understanding the physics of radio frequency signaling. The expanding national rollout of a new fifth-generation (5G) mobile network, coupled with the torrent of scientific data generated by next-generation devices such as battery-powered Internet of Things (IoT) sensors, has created an urgent need to enhance cutting-edge wireless technology. Breakthroughs in the deployment, integration, security, and operational range of wireless networking can provide new scientific capabilities for the next decade - from autonomous mobile instruments for scientific user facilities to intelligent sensors networks distributed over thousands of kilometers to study environmental processes. To realize this promise, however, we must continue to drive innovations in computing, artificial intelligence (AI), advanced materials, high-speed networking, and microelectronics. In March 2020, the DOE-SC convened a workshop to identify the potential opportunities and explore the scientific challenges of advanced wireless technologies.

42 ENGINEERING↗

NESHAPs CY19 Report: Radionuclide Air Emission Report for 2019

Lawrence Livermore National Security, LLC operates facilities at Lawrence Livermore National Laboratory (LLNL) in which radionuclides are handled and stored. These facilities are subject to the U.S. Environmental Protection Agency (EPA) National Emission Standards for Hazardous Air Pollutants (NESHAPs) in Code of Federal Regulations (CFR) Title 40, Part 61, Subpart H, which regulates radionuclide emissions to air from Department of Energy (DOE) facilities. Specifically, NESHAPs limits the emission of radionuclides to the ambient air to levels resulting in an annual effective dose equivalent of 10 mrem (100 μSv) to any member of the public. Using measured and calculated emissions, and building-specific and common parameters, LLNL personnel applied the EPA-approved computer code, CAP88-PC, Version 4.0.1.17, to calculate the dose to the maximally exposed individual member of the public for the Livermore Site and Site 300. In 2019, LLNL maintained its compliance with 40 CFR 61, Subpart H. All radioactive air emissions resulted in calculated doses far below the annual 10 mrem (100 μSv) sitewide standard. The annual doses to the site-wide maximally exposed individual member of the public at the Livermore Site and Site 300 from planned and unplanned operations in 2019 are: Livermore Site: 4.3 x 10⁻³ mrem (4.3 x 10⁻² μSv); Site 300: 9.5 x 10⁻⁸ mrem (9.5 x 10⁻⁷ μSv).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗