Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “scanning mode”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

CSAM Metrology Software Tool

CSAM Metrology Software Tool (CMeST) is a computer program for analysis of false-color CSAM images of plastic-encapsulated microcircuits. (CSAM signifies C-mode scanning acoustic microscopy.) The colors in the images indicate areas of delamination within the plastic packages. Heretofore, the images have been interpreted by human examiners. Hence, interpretations have not been entirely consistent and objective. CMeST processes the color information in image-data files to detect areas of delamination without incurring inconsistencies of subjective judgement. CMeST can be used to create a database of baseline images of packages acquired at given times for comparison with images of the same packages acquired at later times. Any area within an image can be selected for analysis, which can include examination of different delamination types by location. CMeST can also be used to perform statistical analyses of image data. Results of analyses are available in a spreadsheet format for further processing. The results can be exported to any data-base-processing software.

Vu, Duc↗

Comparison Between GOES-12 Overshooting-Top Detections, WSR-88D Radar Reflectivity, and Severe Storm Reports

Studies have found that convective storms with overshooting-top (OT) signatures in weather satellite imagery are often associated with hazardous weather, such as heavy rainfall, tornadoes, damaging winds, and large hail. An objective satellite-based OT detection product has been developed using 11-micrometer infrared window (IRW) channel brightness temperatures (BTs) for the upcoming R series of the Geostationary Operational Environmental Satellite (GOES-R) Advanced Baseline Imager. In this study, this method is applied to GOES-12 IRW data and the OT detections are compared with radar data, severe storm reports, and severe weather warnings over the eastern United States. The goals of this study are to 1) improve forecaster understanding of satellite OT signatures relative to commonly available radar products, 2) assess OT detection product accuracy, and 3) evaluate the utility of an OT detection product for diagnosing hazardous convective storms. The coevolution of radar-derived products and satellite OT signatures indicates that an OT often corresponds with the highest radar echo top and reflectivity maximum aloft. Validation of OT detections relative to composite reflectivity indicates an algorithm false-alarm ratio of 16%, with OTs within the coldest IRW BT range (less than 200 K) being the most accurate. A significant IRW BT minimum typically present with an OT is more often associated with heavy precipitation than a region with a spatially uniform BT. Severe weather was often associated with OT detections during the warm season (April September) and over the southern United States. The severe weather to OT relationship increased by 15% when GOES operated in rapid-scan mode, showing the importance of high temporal resolution for observing and detecting rapidly evolving cloud-top features. Comparison of the earliest OT detection associated with a severe weather report showed that 75% of the cases occur before severe weather and that 42% of collocated severe weather reports had either an OT detected before a severe weather warning or no warning issued at all. The relationships between satellite OT signatures, severe weather, and heavy rainfall shown in this paper suggest that 1) when an OT is detected, the particular storm is likely producing heavy rainfall and/or possibly severe weather; 2) an objective OT detection product can be used to increase situational awareness and forecaster confidence that a given storm is severe; and 3) this product may be particularly useful in regions with insufficient radar coverage.

Dworak, Richard↗

AE (Acoustic Emission) for Flip-Chip CGA/FCBGA Defect Detection

C-mode scanning acoustic microscopy (C-SAM) is a nondestructive inspection technique that uses ultrasound to show the internal feature of a specimen. A very high or ultra-high-frequency ultrasound passes through a specimen to produce a visible acoustic microimage (AMI) of its inner features. As ultrasound travels into a specimen, the wave is absorbed, scattered or reflected. The response is highly sensitive to the elastic properties of the materials and is especially sensitive to air gaps. This specific characteristic makes AMI the preferred method for finding "air gaps" such as delamination, cracks, voids, and porosity. C-SAM analysis, which is a type of AMI, was widely used in the past for evaluation of plastic microelectronic circuits, especially for detecting delamination of direct die bonding. With the introduction of the flip-chip die attachment in a package; its use has been expanded to nondestructive characterization of the flip-chip solder bumps and underfill. Figure 1.1 compares visual and C-SAM inspection approaches for defect detection, especially for solder joint interconnections and hidden defects. C-SAM is specifically useful for package features like internal cracks and delamination. C-SAM not only allows for the visualization of the interior features, it has the ability to produce images on layer-by-layer basis. Visual inspection; however, is only superior to C-SAM for the exposed features including solder dewetting, microcracks, and contamination. Ideally, a combination of various inspection techniques - visual, optical and SEM microscopy, C-SAM, and X-ray - need to be performed in order to assure quality at part, package, and system levels. This reports presents evaluations performed on various advanced packages/assemblies, especially the flip-chip die version of ball grid array/column grid array (BGA/CGA) using C-SAM equipment. Both external and internal equipment was used for evaluation. The outside facility provided images of the key features that could be detected using the most advanced C-SAM equipment with a skilled operator. Investigation continued using in-house equipment with its limitations. For comparison, representative X-rays of the assemblies were also gathered to show key defect detection features of these non-destructive techniques. Key images gathered and compared are: Compared the images of 2D X-ray and C-SAM for a plastic LGA assembly showing features that could be detected by either NDE technique. For this specific case, X-ray was a clear winner. Evaluated flip-chip CGA and FCBGA assemblies with and without heat sink by C-SAM. Only the FCCGA package that had no heat sink could be fully analyzed for underfill and bump quality. Cross-sectional microscopy did not revealed peripheral delamination features detected by C-SAM. Analyzed a number of fine pitch PBGA assemblies by C-SAM. Even though the internal features of the package assemblies could be detected, C-SAM was unable to detect solder joint failure at either the package or board level. Twenty times touch ups by solder iron with 700degF tip temperature, each with about 5 second duration, did not induce defects to be detected by C-SAM images. Other techniques need to be considered to induce known defects for characterization. Given NASA's emphasis on the use of microelectronic packages and assemblies and quality assurance on workmanship defect detection, understanding key features of various inspection systems that detect defects in the early stages of package and assembly is critical to developing approaches that will minimize future failures. Additional specific, tailored non-destructive inspection approaches could enable low-risk insertion of these advanced electronic packages having hidden and fine features.

Ghaffarian, Reza↗

High-Precision Measurement of Eu/Eu* in Geological Glasses via LA-ICP-MS Analysis

Elemental fractionation during laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) analysis has been historically documented between refractory and volatile elements. In this work, however, we observed fractionation between light rare earth elements (LREEs) and heavy rare earth elements (HREEs) when using ablation strategies involving large spot sizes (greater than 100 millimeters) and line scanning mode. In addition: (1) ion yields decrease when using spot sizes above 100 millimeters; (2) (Eu/Eu*)(sub raw) (i.e. Europium anomaly) positively correlates with carrier gas (He) flow rate, which provides control over the particle size distribution of the aerosol reaching the ICP; (3) (Eu/Eu*)(sub raw) shows a positive correlation with spot size, and (4) the changes in REE signal intensity, induced by the He flow rate change, roughly correlate with REE condensation temperatures. The REE fractionation is likely driven by the slight but significant difference in their condensation temperatures. Large particles may not be completely dissociated in the ICP and result in preferential evaporation of the less refractory LREEs and thus non-stoichiometric particle-ion conversion. This mechanism may also be responsible for Sm-Eu-Gd fractionation as Eu is less refractory than Sm and Gd. The extent of fractionation depends upon the particle size distribution of the aerosol, which in turn is influenced by the laser parameters and matrix. Ablation pits and lines defined by low aspect ratios produce a higher proportion of large particles than high aspect ratio ablation, as confirmed by measurements of particle size distribution in the laser induced aerosol. Therefore, low aspect ratio ablation introduces particles that cannot be decomposed and/or atomized by the ICP and thus results in exacerbated elemental fractionation. Accurate quantification of REE concentrations and Eu/Eu* requires reduction of large particle production during laser ablation. For the reference materials analyzed in this work, the 100 millimeters spot measurements of Eu/Eu* agreed with GeoRem preferred values within 3 percent. Our long-term analyses of Eu/Eu* in MPI-DING glass KL-2G and USGS glass BIR-1G were reproducible at 3 percent (2 RSD).

geological glasses↗

A Closer Look at the ABI on the GOES-R Series

The Advanced Baseline Imager (ABI) on board the Geostationary Operational Environmental Satellite-R (GOES-R) is America's next-generation geostationary advanced imager. GOES-R launched on 19 November 2016. The ABI is a state-of-the-art 16-band radiometer, with spectral bands covering the visible, near-infrared, and infrared portions of the electromagnetic spectrum. Many attributes of the ABI-such as spectral, spatial, and temporal resolution; radiometrics; and image navigation/registration-are much improved from the current series of GOES imagers. This paper highlights and discusses the expected improvements of each of these attributes. From ABI data many higher-level-derived products can be generated and used in a large number of environmental applications. The ABI's design allows rapid-scan and contiguous U.S. imaging automatically interleaved with full-disk scanning. In this paper the expected instrument attributes are covered, as they relate to signal-to-noise ratio, image navigation and registration, the various ABI scan modes, and other parameters. There will be several methods for users to acquire GOES-R imagery and products depending on their needs. These include direct reception of the imagery via the satellite downlink and an online-accessible archive. The information from the ABI on the GOES-R series will be used for many applications related to severe weather, tropical cyclones and hurricanes, aviation, natural hazards, the atmosphere, the ocean, and the cryosphere.

GOES-R↗

On-Orbit Special Testing of NOAA-20/JPSS-1 ATMS

The second Advanced Technology Microwave Sounder (ATMS) recently launched November 2017 on the Joint Polar Satellite System-l satellite (JPSS-l), now re-named NOAA-20. It joins the first ATMS flight unit aboard the Suomi NPP (S-NPP) satellite, as well as older sounders-the Advanced Microwave Sounding Units A & B (AMSU-A/B) and Microwave Humidity Sounder (MHS)-on polar-orbiting operational weather satellites. Together, these sounders provide critical all-weather temperature and humidity profile information for Numerical Weather Prediction (NWP) models. This paper presents results from a number of special post-launch tests used to characterize the instrument and provide unique calibration information. These special tests-long stares, alternate techniques for lunar intrusion mitigation and geolocation, spacecraft maneuvers, special scan modes, comparisons with NWP models-require non-standard modes of operation or data analysis, and can only be conducted during commissioning, prior to the start of regular forecast observations.

Kim, Edward↗

Atmospheric Instrument Systems and Technology in the Goddard Earth Sciences Division

Studies of the Earth’s atmosphere require a comprehensive set of observations that rely on instruments flown on spacecraft, aircraft, and balloons as well as those deployed on the surface. Within NASA’s Goddard Space Flight Center (GSFC) Earth Sciences Division-Atmospheres, laboratories and offices maintain an active program of instrument system development and observational studies that provide: 1) information leading to a basic understanding of atmospheric processes and their relationships with the Earth’s climate system, 2) prototypes for future flight instruments, 3) instruments to serve as calibration references for satellite missions, and 4) instruments for future field validation campaigns that support ongoing space missions. Our scientists participate in all aspects of instrument activity, including component and system design, calibration techniques, retrieval algorithm development, and data processing systems. The Atmospheres Program has well-equipped labs and test equipment to support the development and testing of instrument systems, such as a radiometric calibration and development facility to support the calibration of ultraviolet and visible (UV/VIS), space-borne solar backscatter instruments. This document summarizes the features and characteristics of 46 instrument systems that currently exist or are under development. The report is organized according to active, passive, or in situ remote sensing across the electromagnetic spectrum. Most of the systems are considered operational in that they have demonstrated performance in the field and are capable of being deployed on relatively short notice. Other systems are under study or of low technical readiness level (TRL). The systems described herein are designed mainly for surface or airborne platforms. However, two Cubesat systems also have been developed through collaborative efforts. The Solar Disk Sextant (SDS) is the single balloon-borne instrument. The lidar systems described herein are designed to retrieve clouds, aerosols, methane, water vapor pressure, temperature, and winds. Most of the lasers operate at some wavelength combination of 355, 532, and 1064 nm. The various systems provide high sensitivity measurements based on returns from backscatter or Raman scattering including intensity and polarization. Measurements of the frequency (Doppler) shift of light scattered from various atmospheric constitutes can also be made. Microwave sensors consist of both active (radar) and passive (radiometer) systems. These systems are important for studying processes involving water in various forms. The dielectric properties of water affect microwave brightness temperatures, which are used to retrieve atmospheric parameters such as rainfall rate and other key elements of the hydrological cycle. Atmosphere radar systems operate in the range from 9.6 GHz to 94 GHz and have measurement accuracies from -5 to 1 dBZ; radiometers operate in the 50 GHz to 874 GHz range with accuracies from 0.5 to 1 degree K; conical and cross-track scan modes are used. Our passive optical sensors, consisting of radiometers and spectrometers, collectively operate from the UV into the infrared. These systems measure energy fluxes and atmospheric parameters such as trace gases, aerosols, cloud properties, or altitude profiles of various species. Imager spatial resolution varies from 37 m to 400 m depending on altitude; spectral resolution is as small as 0.5 nm. Many of the airborne systems have been developed to fly on multiple aircraft.

Platnick, Steven E.↗

Considerations for Qualifying Reliable Eddy Current Array Technique for Detection of Backwall Cracks

A reliable nondestructive evaluation (NDE) technique provides minimum 90% probability of detection(POD) with 95% confidence for detection of cracklike flaws of a qualified size. In this case, the flaws are on backside of material. Eddy current array (ECA) probe or a single sensor eddy current probe in c-scanning mode is used for the flaw detection. Here, two geometries are considered for the test specimens. The two geometries are, a flat plate, and tube or pipe. The probe is assumed to be on outer diameter (OD)surface and the flaw is assumed to be at the inner diameter (ID) surface for tube inspection. The flaw and probe are on opposite side of wall thickness for inspection of plate material. The application may be used for acreage inspection or just for inspection of butt weld and heat affected zone (HAZ) in a tube, cylinder, or plate. The proposed approach is based on developing an instrument standardization or calibration procedure. Decision threshold of inspection procedure is determined using empirical qualification and noise data. The work explores essential parameters that are required to meet certain conditions to ensure reliable flaw detection. Physics-based simulation of eddy current array flaw detection is used to understand effect of essential parameters on signal response (amplitude and phase),and therefore flaw detectability. Simulation data is used to justify choice of calibration reference standard requirements and the qualification approach. An ECA technique qualification model is provided. The paper gives brief description of tasks to be completed for qualifying ECA technique for reliable detection of cracklike flaws.

Eddy current array inspection, nondestructive eval↗

TOPAS Tool for Particle Simulation

TOPAS lets users simulate the passage of subatomic particles moving through any kind of radiation therapy treatment system, can import a patient geometry, can record dose and other quantities, has advanced graphics, and is fully four-dimensional (3D plus time) to handle the most challenging time-dependent aspects of modern cancer treatments.TOPAS unlocks the power of the most accurate particle transport simulation technique, the Monte Carlo (MC) method, while removing the painstaking coding work such methods used to require. Research physicists can use TOPAS to improve delivery systems towards safer and more effective radiation therapy treatments, easily setting up and running complex simulations that previously used to take months of preparation. Clinical physicists can use TOPAS to increase accuracy while reducing side effects, simulating patient-specific treatment plans at the touch of a button. TOPAS is designed as a “user code” layered on top of the Geant4 Simulation Toolkit. TOPAS includes the standard Geant4 toolkit, plus additional code to make Geant4 easier to control and to extend Geant4 functionality. TOPAS aims to make proton simulation both “reliable” and “repeatable.” “Reliable” means both accurate physics and a high likelihood to simulate precisely what the user intended to simulate, reducing issues of wrong units, wrong materials, wrong scoring locations, etc. “Repeatable” means not just getting the same result from one simulation to another, but being able to easily restore a previously used setup and reducing sources of error when a setup is passed from one user to another. TOPAS control system incorporates key lessons from safety management, proactively removing possible sources of user error such as line-ordering mistakes In control files. TOPAS has been used to model proton therapy treatment examples including the UCSF eye treatment head, the MGH stereotactic alignment in radiosurgery treatment head and the MGH gantry treatment heads in passive scattering and scanning modes, and has demonstrated dose calculation based on patient-specific CT data.

Perl, Joseph↗

System and method for x-ray compatible 2D streak camera for a snapshot multiframe imager

The present disclosure is directed to a snapshot multiframe imager having an aperture element having at least one aperture, an adjacently positioned random mask, an imaging element and a computer. The random mask has a plurality of micron scale apertures and receives light passing through the aperture element, which represents the spatial information from the scene being imaged, and generates a plurality of image frames encoded in a spatial domain. The imaging element may operate in a drift-scan mode receives the encoded image frames and generates a streaked pattern of electrons representing a plurality of images of the scene at a plurality of different times. The computer analyzes the streaked pattern of electrons and mathematically reconstructs the plurality of images.

Dayton, Matthew S.↗

Radiometric characterization process for locating radioactivity hold-up and measuring non-uniformly distributed sources - 15342

A novel approach to facility radiometric characterization for non-uniformly distributed radiation sources has been developed by ANTECH and is currently being employed at the Argonne National Laboratory. It is being applied to the measurement of a wide range of objects and the interiors and contents of laboratories and buildings. The integrated non destructive assay measurement process involves the use of a scanning spectroscopic gamma ray camera as well as high purity Germanium detectors with different collimators and hence differing detector fields of view to measure and quantify non-uniformly distributed sources of radioactivity in laboratory equipment, glove boxes, storage tanks, pipework and general laboratory objects and process components. The purpose of the radiometric characterization is to quantify radiation sources and radioactive contamination levels in facilities containing nuclear material and to ensure compliance with facility characterization requirements and for decontamination and decommissioning planning and execution. The integrated measurement process also involves automated data capture and processing software and a database with which both measurement instrument operators and subject matter expert analysts can interact. An appropriate measuring instrument (gamma camera, scintillation detector, high purity Germanium detector system, neutron detector or alpha-beta counter) records the measurement data and the measurement site is recorded in a photograph. All of the data relevant to the measurement (or set of measurements for a particular object) are recorded in the database including measured gamma ray spectra, equipment description and relevant calibration, measurement site photograph and measurement descriptive data. Once data analysis protocols are established for specific geometries and measurement situations they can be applied to the measured data in a partially automated manner, reducing analysis and transcription errors. In addition to measurements and data analysis the process also utilises radiometric modelling computer codes including MicroShield and Monte Carlo Neutrons Photons in order to perform model calculations where appropriate. In a typical measurement, the ANTECH RadSearch spectroscopic gamma camera is utilized to find areas of concentrated activity so that these areas can be measured and calculated separately from areas with diffuse contamination. The use of the gamma camera in scanning mode helps to ensure that the assay does not overestimate the detected radiation source, which is a frequent consequence of using standard far field geometry and attenuation analysis codes that assume uniformity of both density and radioactive source distribution. Once the hot spots are identified, high purity Germanium detector measurements are made using various collimators with wide or narrow fields of view as required. These measurements are then processed through a semi-automatic calculation process assuming an appropriate source configuration as identified by RadSearch. These source configurations include point sources, line sources or surface sources. The Generalized Geometry Hold-up algorithms are employed to determine an estimate of the activity of the various sources that are identified in a measurement. The ANTECH integrated measurement process provides an automated calculation procedure where the analyst can select the source type, geometry and appropriate input data, and then the software calculates the activity by radionuclide for all sources identified in the measurement. The measurement and analysis process is controlled under the ANTECH ISO9001: 2008 Quality Assurance System and managed by a site specific Quality Assurance Plan. Both Argonne National Laboratory and Department of Energy technical reviewers have vetted the Integrated Measurement and Analysis Process. The application of the measurement and analysis process is described and measurement examples are provided. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Power Electronics Materials and Bonded Interfaces - Reliability and Lifetime

The need for reliable bonded interface materials is critical to realize the performance benefits of wide-bandgap devices in power electronic modules, especially in operating temperatures greater than 150 degrees Celsius. In this paper, we investigate the thermomechanical performance of sintered copper (Cu) as a large-area attachment, bonded between Cu baseplates and active-metal-bonded substrates, under accelerated thermal shock (-40 degrees Celsius to 200 degrees Celsius) conditions. In the fabrication phase of the samples, we used different stencil patterns and found out that the grid and stripe patterns resulted in a better outgassing of the residual organics during the sintering process, thereby ensuring a substantially improved bond quality than a full-area print. The paste consisted of Cu microflakes and we performed sintering using a Budatec SP300 sintering press at 275 degrees Celsius with 15 MPa of bonding pressure for 5 minutes in a nitrogen atmosphere. Under accelerated experiments, we monitored the degradation of the sintered Cu bond in the samples through C-mode scanning acoustic microscope (C-SAM) images. To quantify the defect percentage in C-SAM images, we investigated image denoising techniques to exclude the pattern prints. Finally, we cross-sectioned a sample and obtained digital microscope images, which revealed adhesive fracture as the dominant failure mechanism.

ADVANCED PROPULSION SYSTEMS↗

Studying Gamma-Ray Blazars With the GLAST-LAT

Thanks to its sensitivity (4 10{sup -9} ph (E> 100 MeV) cm{sup -2} s{sup -1} for one year of observation), the GLAST LAT should detect many more (over a thousand) gamma-ray blazars than currently known. This large blazar sample will enable detailed population studies to be carried out. Moreover, the LAT large field-of-view combined with the scanning mode will provide a very uniform exposure over the sky, allowing a constant monitoring of several tens of blazars and flare alerts to be issued. This poster presents the LAT performance relevant to blazar studies, more particularly related to timing and spectral properties. Major specific issues regarding the blazar phenomenon that the LAT data should shed light on thanks to these capabilities will be discussed, as well as the different approaches foreseen to address them. The associated data required in other bands, to be collected in contemporaneous/simultaneous multiwavelength campaigns are mentioned as well.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

p-Carbon CNI polarimetry in the AGS and RHIC.

Proton polarization measurements in the AGS (Alternate Gradient Synchrotron) and RHIC (Relativistic Heavy Ion Collider) are based on proton-carbon(pC) and proton-proton elastic scattering in the Coulomb Nuclear Interference (CNI) region. The CNI polarimeters are the essential tools for polarized proton acceleration setup and operation. High intensity recoil nuclei from the scattering of the circulating proton beam in the thin carbon target is efficiently utilized in the silicon strip detectors and data acquisition system, which is capable to analyze the event rate up to a few millions/second. This makes it possible for the fast, practically non-destructive polarization measurements. The polarization measurement on the beam energy ramp was implemented in AGS and RHIC, providing locations of polarization losses. Polarimeter operation in the scanning mode also gives polarization profile and beam profile (including bunch by bunch values for the later one). This paper summarizes the recent modifications. Results of polarization measurements are also discussed.

43 PARTICLE ACCELERATORS↗

W-Band ARM Scanning Cloud Radar (WSACR) 2nd Generation CF-Radial Spectral Data, Vertically-Pointing Scan, Co-Polarization Mode (a1)

ARM's scanning cloud radars are fully coherent dual-frequency, dual-polarization Doppler radars mounted on a common scanning pedestal. Each pedestal includes a Ka-band radar (2kW peak power) and the deployment location determines whether the second radar is a W-band (WSACR; 1.7 kW peak power) or X-band (XSACR; 20 kW peak power). Beamwidths at Ka and W bands are roughly matched at 0.3 degrees. Due to the narrow antenna beamwidth, ARM’s scanning cloud radars use scanning strategies that are unlike typical weather radars. Rather than focusing on plan position indicator, or PPI, scans, the Ka-SACR uses range height indicator, or RHI, scans at numerous azimuths to obtain cloud volume data. Measurements collected with the W-SACR are copolar and cross-polar radar reflectivity, Doppler velocity, spectra width and spectra when not scanning, and linear depolarization ration.

54 ENVIRONMENTAL SCIENCES↗

Demonstration of Frequency-Scanning Burst-mode Filtered Rayleigh Scattering for Multi-Parameter Gas-Phase Measurements

Filtered Rayleigh scattering (FRS) is a diagnostic technique used for measurements of macroscopic properties of a gas. The FRS signal is passed through a narrow bandwidth molecular filter, commonly gaseous iodine, to measure the broadening and Doppler-shift of the scattering light from the molecules of the gas flow. However, in single-frequency, intensity-based approaches, the effects of pressure, temperature, and velocity can be difficult to deconvolve. To overcome this challenge, frequency-scanning FRS has been used to quasi-spectrally resolve the signal. In this work, a frequency-scanned, burst-mode laser was used to perform scanning FRS in an underexpanded jet to measure temperature, pressure, and radial velocity at measurement rates up to 1 kHz which is ~100,000 times faster than prior implementations of scanning FRS.

filtered Rayleigh scattering↗

Radiochromic film dosimetry: Reflection vs transmission scanning

The objective of this study was to compare the transmission and the reflection scanning reading modes of radiochromic MD-55 films of a document scanner. The use of the red channel of the red-green-blue images results in measurement accuracy that did not differ between the two reading modes. On the other hand, the scanner uniformity and temporal stability, the long-term stability of the film readings and the dynamic range is superior using the reflection mode. The dynamic range of dose measurements can be extended up to least 500 Gy using the alternative color channels by both reading techniques. Similar backscattering dose factors close to high Z inhomogeneities were found using both scanning modes. In conclusion, the use of reflection scanning mode of MD55 films was superior to the traditionally used transmission mode.

61 RADIATION PROTECTION AND DOSIMETRY↗

Luminescence of Quantum Dots by Coupling with Nonradiative Surface Plasmon Modes in a Scanning Tunneling Microscope

The electronic coupling between quantum dots (QDs) and surface plasmons (SPs) is investigated by a luminescence spectroscopy based on scanning tunneling microscopy (STM). We show that tunneling luminescence from the dot is excited by coupling with the nonradiative plasmon mode oscillating at the metallic tunneling gap formed during the STM operation. This approach to the SP excitation reveals aspects of the SP-QD coupling not accessible to the more conventional optical excitation of SPs. In the STM, luminescence from the dot is observed when and only when the SP is in resonance with the fundamental transition of the dot. The tunneling luminescence spectrum also suggests that excited SP-QD hybrid states can participate in the excitation of QD luminescence. Not only the SP excitation regulates the QD luminescence but the presence of the dot at the tunneling gap imposes restrictions to the SP that can be excited in the STM, in which the SP cannot exceed the energy of the fundamental transition of the dot. The superior SP-QD coupling observed in the STM is due to the tunneling gap acting as a tunable plasmonic resonator in which the dot is fully immersed.

77 NANOSCIENCE AND NANOTECHNOLOGY↗