Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “sample preparation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Examining phase separation and crystallization in glasses with X-ray nano-computed tomography

X-ray nano-computed tomography (nano-CT) is a powerful technique to characterize and visualize 3 dimensional (3D) phenomena in complex glasses at the nanoscale. This technique can offer a unique opportunity to explore the intricate morphology of multicomponent glass and glass-ceramic samples, due to its low X-ray energy and high spatial resolution (down to 50 nm). In the current demonstration paper, nano-CT provided insight into crystallization and phase separation, as well as a variety of other phenomena, including corrosion, fracture, and porosity. At scales ranging from 100 to 20 μm, the microstructures of phase separation in borosilicate, complex silicate, and chalcogenide glass compositions were examined. In addition, crystallites present in simulant nuclear waste glasses, volcanic glasses, and other related samples were explored. Nano-CT analysis can add to the understanding of (1) the formation processes, (2) distributions, interactions, and compositions of phases, and (3) the mechanisms, structures, and growth of crystallization and phase separation. Nano-CT offers wide potential in the field of glass science, especially when (1) common characterization methods are insufficient, (2) simple sample preparation is required, (3) 3D rendering is needed, or (4) compelling images of small, complex features are desired.

36 MATERIALS SCIENCE↗

Characterization of zirconium carbide microspheres synthesized via internal gelation

Microspheres of zirconium carbide with grain size 40-320 nm were synthesized using internal gelation techniques and characterized by scanning electron microscopy, synchrotron X-ray diffraction, and neutron total scattering. Compared with a polycrystalline benchmark ZrC sample prepared by plasma vapor phase deposition, the microspheres display lower variance in grain size and considerably lower microstrain representative of a more homogenous internal microstructure. However, excess carbon was present in the microspheres, evident in both the X-ray and neutron diffraction data as well as a corresponding hypostoichiometric ZrC phase. Furthermore, the excess carbon phase is assumed to be pockets of carbon that remained unreacted through the combined internal gelation and subsequent carbothermic reduction synthesis process. Atomic-scale structural characterization with neutron PDF analysis confirmed the presence of localized nano-sized domains of graphite-like carbon material.

36 MATERIALS SCIENCE↗

Transmission electron microscopy study of a high burnup U-10Zr metallic fuel

To support the development of U-10 wt.% Zr (U-10Zr) metallic fuel for Gen IV sodium-cooled fast reactors, we analysed a solid, Na-bonded, U-10Zr (by weight percent) fuel cross section that was irradiated to a burnup of ~ 12.4 % at.% at the Fast Flux Test Facility (FFTF). Advanced characterization techniques, including site specific sample preparation by focused ion beam (FIB) and phase/chemical determination by transmission electron microscopy (TEM), were used to reveal the constituent redistribution of Zr, characterize the fuel phases and the secondary phases (such as solid fission products) present at the end of life. It is shown that the fuel pin cross section is divided into three major concentric zones: a Zr-rich central region, a Zr-lean intermediate region, and a Zr intermediate peripherical region. The phase characterization revealed that the irradiation environment enhanced the development and stabilization of phases not predicted by the standard equilibrium U-Zr phase diagrams. Comparing the current results with the ones from previous studies, it is reaffirmed that the irradiation temperature and the time spent in the reactor, rather than the fuel burnup, are the two factors that most influence the formation of redistribution zones and their extension along the fuel cross section. Various solid fission products precipitated inside the fission gas pores, such as lanthanides, ZrRu, BaTe, CsI, and Ba and Sr oxides. Here, this study provides unprecedented nanoscale understandings in the U-10Zr fuel system that may benefit fuel performance modelling and advanced fuel development.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Exploring the relationship between solvent-assisted ball milling, particle size, and sintering temperature in garnet-type solid electrolytes

Garnet-type solid electrolytes, such as Li 6.4 La 3 Zr 1.4 Ta 0.6 O 12 (LLZTO), are promising materials for solid-state batteries, but processing remains a challenge, in part due to the high sintering temperature required for densification. Additionally, this temperature can be lowered by decreasing the initial particle size via solvent-assisted ball milling, but the relationship between solvent choice, particle properties, sintering behavior, and ionic conductivity is not well understood. In this work, we systematically explore these parameters, showing that milling in commonly used protic solvents, such as alcohols, effectively decreases the particle size but results in lithium loss (through Li + /H + exchange) that leads to poor sintering. By contrast, milling in aprotic solvents with surfactant reduces the particle size to ~220 nm without lithium loss, enabling the fabrication of dense samples (5.1 g/cm 3 ) with good ionic conductivity (0.43 mS/cm at 25 °C) at a lower sintering temperature (1000 °C). We compare ionic conductivities and activation energies for samples prepared with different particle sizes and sintering temperatures and use multiphase-field simulations to identify the mass transport and microstructural mechanisms responsible for the observed sintering dependence on particle size. These results further clarify the relationship between processing parameters and performance and represent important progress toward overcoming fabrication challenges for these materials.

25 ENERGY STORAGE↗

Radiative transition probabilities of neutral and singly ionized rare earth elements (La, Ce, Pr, Nd, Sm, Gd, Tb, Dy, Ho, Er, Tm, Yb, Lu) estimated by laser-induced breakdown spectroscopy

Rare earth elements (REEs) are essential to society given their prevalence in many modern technologies. Quantitative elemental analysis of REEs is therefore a critical capability. Calibration free–laser-induced breakdown spectroscopy (CF-LIBS) is a rapidly maturing and promising approach to quantitative elemental analysis with many attractive qualities. The application of CF-LIBS to analyzing samples containing the REEs is hindered by a lack of fundamental data, specifically transition probabilities (TPs). As such, this study seeks to help address this knowledge deficiency by reporting 967 previously unreported TPs for 13 REEs (lanthanum, cerium, praseodymium, neodymium, samarium, gadolinium, terbium, dysprosium, holmium, erbium, thulium, ytterbium, and lutetium). The method developed in this study to estimate the TPs requires small amounts of material (a few nanograms) compared with other approaches (~ milligrams), uses non-specialized equipment, and does not involve complicated sample preparations.

(LIBS)↗

Structure and electronic properties of CaAl 12₋x Fe x O19 hibonites

Dilution of iron in the AM 12 O 19 has shown promising coupling of magnetic and electric properties in the hexaferrites. In this study, we have prepared samples of low iron content in the isostructural hibonite, CaAl 12 -x Fe x O 19 , to investigate the structural effects of larger iron substitution into the aluminum sites and the resultant properties. We found a solid solution exists for CaAl 12 -x Fe x O 19 where x ≤ 5 . 5. Iron distributes into all sites with the tetrahedral M3 and octahedral M5 sites displaying nominally larger preference at higher Fe content. Paramagnetic behavior was observed for x = 1-3, while x = 4-5.5 displayed a broad ferromagnetic-like transition with increasing Curie temperature. Differences in field-cooled and zero-field-cooled magnetic susceptibility measurements and low magnetic moment indicate the presence of a frustrated antiferromagnetic structure as the source of the ferromagnetic-like behavior. Increasing Fe content also increases the dielectric constant up to 21 at room temperature with high dielectric loss.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Synergistic Effects of Molten Salt Corrosion and Proton Irradiation on Grain Boundary Strength in Ni-20Cr

Nickel-based alloys are leading contenders for use as structural materials in molten salt reactors. While there have been extensive studies on the impact of fluoride/chloride-based molten salt corrosion on the microstructural evolution of various nickel-based alloys, the effects of simultaneous molten salt corrosion and radiation on the mechanical integrity of grain boundaries (GBs) remain underexplored. In this study, we use a Ni-20Cr model alloy to investigate this issue, subjecting it to simultaneous molten fluoride salt corrosion and proton irradiation. We performed cross-sectional and chemically-sensitive electron microscopy characterization of the microstructures of these materials, identifying the characteristic corrosion-induced microstructure and local chemical heterogeneity near GBs. After developing a sample preparation method for reliable characterization of GB strength, we assess the mechanical degradation of GBs using in situ push-to-pull micro tensile tests. Our findings reveal that voids induced by corrosion are the primary influence on the failure mode of GBs, regardless of whether proton irradiation is present. For materials that exhibit ductile fracture, those subjected to simultaneous corrosion and radiation exhibit lower yield strengths than those exposed to corrosion alone, which may be linked to the previously observed phenomenon of proton irradiation-decelerated intergranular corrosion in molten salt.

36 - MATERIALS SCIENCE↗

Strong interlayer coupling and long-lived interlayer excitons in two-dimensional perovskite derivatives and transition metal dichalcogenides van der Waals heterostructures

Two-dimensional (2D) van der Waals (vdW) heterostructures offer new platforms for exploring novel physics and diverse applications ranging from electronics and photonics to optoelectronics at the nanoscale. The studies to date have largely focused on transition-metal dichalcogenides (TMDCs) based samples prepared by mechanical exfoliation method, therefore it is of signi ficant interests to study high-quality vdW heterostructures using novel materials prepared by a versatile method. Here, we report a two-step vapor phase growth process for the creation of high-quality vdW heterostructures based on perovskites and TMDCs, such as 2D Cs 3 Bi 2 I 9 /MoSe 2 , with a large lattice mismatch. Supported by experimental and theoretical investigations, we discover that the Cs 3 Bi 2 I 9 /MoSe 2 vdW heterostructure possesses hybrid band alignments consisting of type -I and type-II heterojunctions because of the existence of defect energy levels in Cs 3 Bi 2 I 9 . More importantly, we demonstrate that the type-II heterojunction in the Cs 3 Bi 2 I 9 /MoSe 2 vdW heterostructure not only shows a higher interlayer exciton density, but also exhibits a longer interlayer exciton lifetime than traditional 2D TMDCs based type-II heterostructures. We attribute this phenomenon to the reduced overlap of electron and hole wavefunctions caused by the large lattice mismatch. Finally, our work demonstrates that it is possible to directly grow high-quality vdW heterostructures based on entirely different materials which provide promising platforms for exploring novel physics and cutting-edge applications, such as optoelectronics, valleytronics, and high-temperature super fluidity.

36 MATERIALS SCIENCE↗

ToF-SIMS in material research: A view from nanoscale hydrogen detection

Hydrogen in materials has attracted tremendous interest as its incorporation leads to significant alterations in nanoscale structure, composition, and chemistry, impacting functional properties. It has also been integral to nuclear fusion reactors and is considered a future clean energy source. However, nanoscale characterization and manipulation of hydrogen in materials are challenging as only a selected few analytical techniques can readily detect hydrogen, among which time-of-flight secondary ion mass spectrometry (ToF-SIMS) is a unique and powerful one due to its excellent detection limit along with decent depth and lateral resolutions. Here, in this review, we discuss, using selected examples, how to detect and quantify hydrogen in materials by ToF-SIMS and its impact on revealing the hydrogenation/protonation-induced novel functional states in different classes of materials. In addition, we present our protocols on sample preparation and experimental conditions optimization, allowing us to achieve the best possible results. Finally, we highlight future research directions that can lead to the discovery of novel functional states and ultimately provide a deeper understanding of scientific questions in materials science.

36 MATERIALS SCIENCE↗

Multi-lab study on the pure-gas permeation of commercial polysulfone (PSf) membranes: Measurement standards and best practices

Gas-separation membranes are a critical industrial component for a low-carbon and energy-efficient future. As a result, many researchers have been testing membrane materials over the past several decades. Unfortunately, almost all membrane-based testing systems are home-built, and there are no widely accepted material standards or testing protocols in the literature, making it challenging to accurately compare experimental results. Further, in this multi-lab study, ten independent laboratories collected high-pressure pure-gas permeation data for H 2 , O 2 , CH 4 , and N 2 in commercial polysulfone (PSf) films. Equipment information, testing procedures, and permeation data from all labs were collected to provide (1) accepted H 2 , O 2 , CH 4 , and N 2 permeability values at 35°C in PSf as a reference standard, (2) statistical analysis of lab-to-lab uncertainties in evaluating permeability, and (3) a list of best practices for sample preparation, equipment set-up, and permeation testing using constant-volume variable-pressure apparatuses. Results summarized in this work provide a reference standard and recommended testing protocols for pure-gas testing of membrane materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

10 Be at iThemba LABS using a silicon nitride membrane stack as absorber for isobar suppression

10 Be is an important isotope for accelerator mass spectrometry (AMS) because of the demand for cosmogenic radionuclide dating methods in the earth science and paleo-sciences community. At the iThemba Laboratory for Accelerator Based Science (iThemba LABS) we implemented full suppression of the interfering isobar 10 B using a silicon nitride foil-stack, utilizing the 2+ charge state for high efficiency. We demonstrate the performance of this newly established AMS system using standards and test samples. Here we further present the results of an inter-comparison between iThemba LABS and the Center for Accelerator Mass Spectrometry/Lawrence Livermore National Laboratory, on AMS samples prepared from purified quartz at the University of Vermont. The results for 10 Be from the laboratories are in close agreement, fully consistent with cross-calibration between them. AMS results for 26 Al are in similarly good agreement, demonstrating the performance and accuracy of iThemba LABS for the most commonly measured in situ produced cosmogenic nuclides.

10-Be↗

Creep suppression and fatigue in bio-based composites manufactured via conventional and large format additive manufacturing processes

The emergence of novel extrusion-based additive manufacturing (AM) processes has prompted the development of new thermoplastic composite feedstocks, and broadening sustainability initiatives have driven the development of bio-based and recyclable material for AM feedstocks. Poly(lactic acid) (PLA) with wood flour (WF) is one composite system that has been demonstrated in numerous AM applications, as well as traditional processing methods (i.e., compression and injection molding); however, there has been a need to understand how the variation in processing methodology impacts the material performance of these bio-based feedstocks from a fundamental perspective, with particular emphasis on creep for an extended application use-life. Herein, PLA/WF is explored as a feedstock material for large format additive manufacturing (LFAM) and the performance of additively manufactured materials is compared to those produced via more traditional processing methods. It is also demonstrated that the addition of WF decreases the material’s coefficient of thermal expansion (CTE) while increasing its Young’s modulus, susceptibility to water uptake, and creep fatigue resistance. Essentially, the addition of 20 wt% WF results in a 92 % decrease in rubbery regime CTE while simultaneously resulting in a 14 % increase in modulus, 190 % increase in water uptake, and a 31 % decrease in residual strain after cyclic creep tests. The processing method was also found to play a large role in the final part performance, with the printed material increasing the crystallinity by 183 % and 214 % compared to its compression and injection molded counterparts. Furthermore, the porosity of printed samples increased by two orders of magnitude compared to samples prepared via traditional processing methods.

36 MATERIALS SCIENCE↗

Direct comparison of gamma, electron beam and X-ray irradiation doses on characteristics of low-density polyethylene, polypropylene homopolymer, polyolefin elastomer and chlorobutyl rubber medical device polymers

There is a growing need for increased efficiency in the sterilization of single use medical devices and other products that contain polymer components. Gamma radiation is widely used for devices suited for radiation sterilization; however, safety, throughput and cobalt-60 source availability are challenging the prospect of relying on gamma radiation to meet the anticipated needs of the industry. Use of electron beam (e-beam) and X-rays as alternatives to gamma for radiation sterilization have been hampered in part by a concern that these modalities may adversely affect polymer integrity and performance relative to the gamma method, for which the industry has had much more experience. To address this concern, the effects of sterilization-relevant doses of ebeam, X-ray and gamma radiation were directly compared using common medical device polymers found in two prototypical commercial devices currently sterilized using cobalt-60 gamma irradiation. The Becton, Dickinson and Company (BD) Vacutainer™ Plus tube contains low-density polyethylene and chlorobutyl rubber components, while the BD Vacutainer™ Push Button Blood Collection Set contains polypropylene homopolymer and polyolefin elastomer components. Injection-molded samples prepared from the polymers used in these products were exposed to target doses of 15, 35, 50 and 80 kGy using gamma, e-beam and X-ray radiation. Changes in coloration, tensile properties and hardness were measured for each condition, and the effects of e-beam and X-ray irradiation compared with the effects of gamma irradiation on these properties. Both e-beam and X-ray appear as viable alternatives to gamma irradiation for sterilization of the polymers tested.

sterilization, gamma, X-ray, electron beam, radiat↗

Wet-chemical etching of FIB lift-out TEM lamellae for damage-free analysis of 3-D nanostructures

Reducing ion beam damage from the focused ion beam (FIB) during fabrication of cross sections is a well-known challenge for materials characterization, especially cross sectional characterization of nanostructures. To address this, a new method has been developed for cross section fabrication enabling high resolution transmission electron microscopy (TEM) analysis of 3-D nanostructures free of surrounding material and free of damage detectable by TEM analysis. Before FIB processing, nanopillars are encapsulated in a sacrificial oxide which acts as a protective layer during FIB milling. Furthermore, the cross sectional TEM lamella containing the nanopillars is then mounted and thinned with some modifications to conventional FIB sample preparation that provide stability for the lamella during the following wet-chemical dip etch. The wet-chemical etch of the TEM lamella removes the sacrificial oxide layer, freeing the nanopillars from any material that would obscure TEM imaging. Both high resolution TEM and aberration corrected scanning TEM images of Si/SiGe pillars with diameters down to 30 nm demonstrate the successful application of this approach.

3-d nanostructure analysis↗

A Denoising Autoencoder for Improved Kikuchi Pattern Quality and Indexing in Electron Backscatter Diffraction

The rapid collection and indexing of electron diffraction patterns as produced via electron backscatter diffraction (EBSD) has enabled crystallographic orientation and structural determination, as well as additional property-determining strain and dislocation density information with increasing speed, resolution, and efficiency. Pattern indexing quality is reliant on the noise of the collected electron diffraction patterns, which is often convoluted by sample preparation and data collection parameters. EBSD acquisition is sensitive to many factors and thus can result in low confidence index (CI), poor image quality (IQ), and improper minimization of fit, which can result in noisy datasets and misrepresent the microstructure. In an attempt to enable both higher speed EBSD data collection and enable greater orientation fit accuracy with noisy datasets, an image denoising autoencoder was implemented to improve pattern quality. Here, we show that EBSD data processed through the autoencoder results in a higher CI, IQ, and a more accurate degree of fit. In addition, using denoised datasets in HR-EBSD cross correlative strain analysis can result in reduced phantom strain from erroneous calculations due to the increased indexing accuracy and improved correspondence between collected and simulated patterns.

36 MATERIALS SCIENCE↗

Atomic-scale characterization of (electro-)catalysts and battery materials by atom probe tomography

To optimise the performance of heterogeneous (electro-)catalysts and battery electrodes, it is essential to establish the structure-property relationships. This can only be achieved by obtaining a full three-dimensional (3D) characterisation of atomic-scale structure and chemistry of these advanced materials. Atom probe tomography (APT) can provide unique insights into 3D elemental distribution, including low atomic mass elements, with sub-nanometer spatial resolution. Despite its superior chemical analytical capability and spatial resolution, APT has limited applications for sustainable energy materials due to technical and analytical challenges. The recent developments in experimental setups, sample preparation methods and data analysis algorithms have opened the door to the possibility of analysing heterogeneous (electro-)catalysts and battery electrodes. This perspective provides an overview of these developments, exemplified by recent achievements of analyzing model heterogeneous model (electro-)catalysts, nanoparticles, zeolites, MOFs and Li-ion battery electrodes, followed by a discussion of limitations, opportunities, and potentials of APT for future scientific exploration.

atom probe tomography↗

Enhanced Spatial Mapping of Histone Proteoforms in Human Kidney Through MALDI-MSI by High-Field UHMR-Orbitrap Detection

Core histones including H2A, H2B, H3, and H4 are key modulators of cellular repair, transcription, and replication within eukaryotic cells, playing vital roles within the pathogenesis of disease and cellular responses to environmental stimuli. Traditional mass spectrometry (MS) based bottom-up and top-down proteomics allows for the comprehensive identification of proteins and of post-translational modification (PTM) harboring proteoforms. However, these methodologies have difficulties preserving near cellular spatial distributions because they typically require laser capture microdissection (LCM) and advanced sample preparation techniques. Herein, we coupled matrix-assisted laser desorption/ionization (MALDI) source with a Thermo Scientific Q-Exactive HF Orbitrap MS upgraded with ultra-high mass range (UHMR) boards for the first demonstration of complementary high-resolution accurate mass measurements of proteoforms directly from tissue using this benchtop mass spectrometer. The platform achieved isotopic resolution throughout the detected mass range, providing confident assignments of proteoforms with low ppm mass error and a vastly improved duty cycle over other Fourier transform mass analyzers. Proteoform mapping of core histones was demonstrated on sections of human kidney at near-cellular spatial resolution, with several key distributions of histone and other proteoforms noted within both healthy biopsy and a section from a renal cell carcinoma (RCC) containing nephrectomy. Further, the use of MALDI-MS imaging (MSI) for proteoform mapping demonstrates several steps towards high-throughput accurate identification of proteoforms and provides a new tool for mapping biomolecule distributions throughout tissue sections in extended mass ranges.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ionic Liquids in Analytical Chemistry: Fundamentals, Technological Advances, and Future Outlook

The development of new analytical methods most often focus on novel materials used to impart selectivity or sensitivity to the protocol. Ionic liquids (ILs) are a class of solvents that have been extensively explored as promising materials for various applications and continue to be explored due to their tunable physicochemical properties. These materials possess melting temperatures below 100 °C and can interact with analytes through a multitude of interactions afforded by their readily tunable chemical structure. These interactions include electrostatic, dispersive, hydrogen bonding, π–π, and dipolar interactions and can be modulated or strengthened based on the functional groups present within the chemical structure. ILs consist predominately of organic cations and either inorganic or organic anions, both of which can be functionalized with desired moieties. Common cation and anions found in IL chemical structures are presented in Figure 1. The unique polarity afforded by the ionic structure has also led to their increasing use in areas including sample preparation, chemical separations, electrochemistry, mass spectrometry, and spectroscopy.

Zeger, Victoria R. [Iowa State Univ., Ames, IA (Un↗