Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “sample delivery”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Testing and validation of the microbial environment of the NASA rodent spaceflight habitat water delivery system.

Sterilized, deionized water within a closed, self-sufficient system has been used in NASA spaceflight rodent studies for several decades. Within the specialized spaceflight rodent habitat, water is delivered through a compression spring-loaded bag system to maintain positive pressure. Refill of the drinking water occurs every 30 days by direct transfer of potable water from aboard the International Space Station (ISS). This enables long term use without a weekly water change out, which meets spaceflight requirements, but contrasts with the general guidelines for the sanitation of water delivery systems. Even though the water is iodinated to minimize microbial growth, rodents are fed a special diet of high moisture nutrient-rich food bars based on the AIN-93 diet that may contribute to microbial growth in this water system. We designed a ground study to assess the quality of drinking water that is given to rodents throughout a mission. We conducted the ground test using 20 female C57BL/6J mice housed in this specialized habitat to mimic the timeline of a 90-day mission as well as the environmental conditions (temperature, humidity, and pCO2) within the ISS. We used a novel sampling method to test water at 2-week intervals for the 90-days, and also after each 30-day refill of the water delivery system. Mice in standard vivarium cages with water bottles were also included for comparison to the habitat. The results showed that overall microbial load remained close to zero for the duration, while total organic compound concentrations increased from 1370g/L to 10650g/L over the course of 90 days but remained below the level of concern. Inorganic ions and pH were also found to be at acceptable levels. Overall, we conclude that this system is effective in delivering clean, potable water to rodents for the 90-day duration of current missions to the ISS.

water↗

The Case for Columnar Analysis (a Two-Part Series) [PowerPoint]

This talk provides prologue terminology and technology. Part I covers analyzer experience including user experience, code samples, domain of applicability, and scalability. Part II discusses technical underpinnings including theoretical motivation, the Coffea framework, factorized data delivery, package ecosystem, performance, and future directions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

High-Throughput Microfluidic Electroporation (HTME): A Scalable, 384-Well Platform for Multiplexed Cell Engineering

Electroporation-mediated gene delivery is a cornerstone of synthetic biology, offering several advantages over other methods: higher efficiencies, broader applicability, and simpler sample preparation. Yet, electroporation protocols are often challenging to integrate into highly multiplexed workflows, owing to limitations in their scalability and tunability. These challenges ultimately increase the time and cost per transformation. As a result, rapidly screening genetic libraries, exploring combinatorial designs, or optimizing electroporation parameters requires extensive iterations, consuming large quantities of expensive custom-made DNA and cell lines or primary cells. To address these limitations, we have developed a High-Throughput Microfluidic Electroporation (HTME) platform that includes a 384-well electroporation plate (E-Plate) and control electronics capable of rapidly electroporating all wells in under a minute with individual control of each well. Fabricated using scalable and cost-effective printed-circuit-board (PCB) technology, the E-Plate significantly reduces consumable costs and reagent consumption by operating on nano to microliter volumes. Furthermore, individually addressable wells facilitate rapid exploration of large sets of experimental conditions to optimize electroporation for different cell types and plasmid concentrations/types. Use of the standard 384-well footprint makes the platform easily integrable into automated workflows, thereby enabling end-to-end automation. We demonstrate transformation of E. coli with pUC19 to validate the HTME's core functionality, achieving at least a single colony forming unit in more than 99% of wells and confirming the platform's ability to rapidly perform hundreds of electroporations with customizable conditions. This work highlights the HTME's potential to significantly accelerate synthetic biology Design-Build-Test-Learn (DBTL) cycles by mitigating the transformation/transfection bottleneck.

Gaillard, William R↗

A Search for Extraterrestrial Amino Acids in Polar Ice: A Progress Report

Fifteen polar ice samples-fourteen from Greenland and one from Antarctica-have been analyzed for the extraterrestrial amino acid alpha-aminoisobutyric acid (AIB) in an effort to estimate the flux of interplanetary organic material to the Earth's surface. Only one sample (Greenland GISP II, 4270-4440 years old) contains detectable amounts of AIB, apparently the signature of a transient delivery event. The maximum oceanic concentration of AIB from such an event would be less than 10(exp-9) M.

Bada, Jeffrey L.↗

Quantitative Electron Beam‐Single Atom Interactions Enabled by Sub‐20‐pm Precision Targeting

The ability to probe and control matter at the picometer scale is essential for advancing quantum and energy technologies. Scanning transmission electron microscopy offers powerful capabilities for materials analysis and modification, but sample damage, drift, and scan distortions hinder single atom analysis and deterministic manipulation. Materials analysis and modification via electron–solid interactions can be transformed by precise delivery of electrons to a specified atomic location, maintaining the beam position despite drift, and minimizing collateral dose. Here a fast, low-dose, sub-20-pm precision electron beam positioning technique is developed, “atomic lock-on,” (ALO), which offers the ability to position the beam on a specific atomic column without previously irradiating that column. This technique is used to lock onto a single selected atomic location to repeatedly measure its weak electron energy loss signal despite sample drift. Moreover, electron beam-matter interactions in single atomic events are measured with μ s time resolution. This enables observation of single-atom dynamics, such as atomic bistability, revealing partially bonded atomic configurations and recapture phenomena. This opens prospects for using electron microscopy for high-precision measurements and deterministic control of matter for quantum technologies.

2D materials↗

Investigating the Sources and Timing of Projectiles Striking the Lunar Surface

The lunar surface is exposed to bombardment by asteroids, comets, and debris from them. Surviving fragments of those projectiles in the lunar regolith provide a direct measure of the sources of exogenous material delivered to the Moon. Con-straining the temporal flux of their delivery will directly address key questions about the bombardment history of the inner Solar System. Regolith breccias, which are consolidated samples of the lunar regolith, were closed to further impact processing at the time they were assembled into rocks [1]. They are, therefore, time capsules of impact bombardment at different times through lunar history. Here we investigate the impact archive preserved in the Apollo 16 regolith breccias and compare this record to evidence of projectile species in other lunar samples.

Joy, K. H.↗

SU-E-T-267: Proton Pencil Beam Scanning for Mediastinal Lymphoma: 4-Dimensional Feasibility Study

Purpose: To assess the feasibility of proton pencil beam scanning (PBS) for the treatment of mediastinal lymphoma. Methods: A group of 6 patients were planned using an anterior field with PBS. Spots with ∼5 mm σ were used for all patients, while large spots (∼10 mm σ) were employed for patients with motion perpendicular to the beam (≥5 mm). We considered volumetric repainting such that, in each fraction, the same field would be delivered twice. Four-dimensional dose was calculated on initial and verification 4-dimensional computed tomography (4D-CT) scans (2—3) based on respiratory trace and beam delivery sequence. This was implemented by binning the spots into separate plans on each 4D-CT phase respectively. Four starting phases were sampled for each painting and 4 energy switching times (0.5 s, 1 s, 3 s, and 5 s) were tested, resulting in 2560 dose distributions for the cohort. Plan robustness was measured for target and critical structures in terms of the percentage difference between delivered dose and planned dose. Results: For 5 of the 6 patients, the ITV (internal target volume) D 98% was degraded by <3% (standard deviations ∼ 0.1%) when averaged over the whole course (up to 5% per fraction). Deviations of mean lung dose, heart maximum dose, and cord maximum dose were within 5% of prescribed dose. For one patient with motion perpendicular to the beam (up to 5 mm), the degradation of ITV D 98% was 9% over the whole course (12% per fraction), which was mitigated to 1% (3% per fraction) by employing large spots and repainting. No significant difference in coverage was observed for different energy switching times. Conclusion: This feasibility study demonstrates that, for mediastinal lymphoma, the PBS plan robustness can be maintained during delivery when target motion is measured and volumetric repainting and/or large spots are employed. This work was supported by Ion Beam Application.

60 APPLIED LIFE SCIENCES↗

Diagnostic/drug delivery "sense-respond" devices, systems, and uses thereof

The present invention is directed to devices, systems, and methods for detecting and/or monitoring one or more markers in a sample. In particular, such devices integrate a plurality of hollow needles configured to extract or obtain a fluid sample from a subject, as well as transducers to detect a marker of interest.

47 OTHER INSTRUMENTATION↗

Provenance information as a tool for addressing engineered nanoparticle reproducibility challenges

Nanoparticles of various types are of increasing research and technological importance in biological and other applications. Difficulties in the production and delivery of nanoparticles with consistent and well defined properties appear in many forms and have a variety of causes. Among several issues are those associated with incomplete information about the history of particles involved in research studies including the synthesis method, sample history after synthesis including time and nature of storage and the detailed nature of any sample processing or modification. In addition, the tendency of particles to change with time or environmental condition suggests that the time between analysis and application is important and some type of consistency or verification process can be important. The essential history of a set of particles can be identified as provenance information tells the origin or source of a batch of nano-objects along with information related to handling and any changes that may have taken place since it was originated. A record of sample provenance information for a set of particles can play a useful role in identifying some of the sources and decreasing the extent of particle variability and the observed lack of reproducibility observed by many researchers.

Environmental Molecular Sciences Laboratory↗

Sampling and Chemical Analysis of Potable Water for ISS Expeditions 12 and 13

The crews of Expeditions 12 and 13 aboard the International Space Station (ISS) continued to rely on potable water from two different sources, regenerated humidity condensate and Russian ground-supplied water. The Space Shuttle launched twice during the 12- months spanning both expeditions and docked with the ISS for delivery of hardware and supplies. However, no Shuttle potable water was transferred to the station during either of these missions. The chemical quality of the ISS onboard potable water supplies was verified by performing ground analyses of archival water samples at the Johnson Space Center (JSC) Water and Food Analytical Laboratory (WAFAL). Since no Shuttle flights launched during Expedition 12 and there was restricted return volume on the Russian Soyuz vehicle, only one chemical archive potable water sample was collected with U.S. hardware and returned during Expedition 12. This sample was collected in March 2006 and returned on Soyuz 11. The number and sensitivity of the chemical analyses performed on this sample were limited due to low sample volume. Shuttle flights STS-121 (ULF1.1) and STS-115 (12A) docked with the ISS in July and September of 2006, respectively. These flights returned to Earth with eight chemical archive potable water samples that were collected with U.S. hardware during Expedition 13. The average collected volume increased for these samples, allowing full chemical characterization to be performed. This paper presents a discussion of the results from chemical analyses performed on Expeditions 12 and 13 archive potable water samples. In addition to the results from the U.S. samples analyzed, results from pre-flight samples of Russian potable water delivered to the ISS on Progress vehicles and in-flight samples collected with Russian hardware during Expeditions 12 and 13 and analyzed at JSC are also discussed.

Straub, John E. II↗

Temporal Sampling of Enzymes from Live Cells by Localized Electroporation and Quantification of Activity by SAMDI Mass Spectrometry

Abstract Measuring changes in enzymatic activity over time from small numbers of cells remains a significant technical challenge. In this work, a method for sampling the cytoplasm of cells is introduced to extract enzymes and measure their activity at multiple time points. A microfluidic device, termed the live cell analysis device (LCAD), is designed, where cells are cultured in microwell arrays fabricated on polymer membranes containing nanochannels. Localized electroporation of the cells opens transient pores in the cell membrane at the interface with the nanochannels, enabling extraction of enzymes into nanoliter‐volume chambers. In the extraction chambers, the enzymes modify immobilized substrates, and their activity is quantified by self‐assembled monolayers for matrix‐assisted laser desorption/ionization (SAMDI) mass spectrometry. By employing the LCAD‐SAMDI platform, protein delivery into cells is demonstrated. Next, it is shown that enzymes can be extracted, and their activity measured without a loss in viability. Lastly, cells are sampled at multiple time points to study changes in phosphatase activity in response to oxidation by hydrogen peroxide. With this unique sampling device and label‐free assay format, the LCAD with SAMDI enables a powerful new method for monitoring the dynamics of cellular activity from small populations of cells.

Mukherjee, Prithvijit↗

In Situ Geochronology for the Next Decade

Geochronology, or determination of absolute ages for geologic events, underpins many inquiries into the formation and evolution of planets and our Solar System. The bombardment chronology inferred from lunar samples has played a significant role in the development of models of early Solar System and extrasolar planet dynamics, as well as the timing of volatile, organic, and siderophile element delivery. Absolute ages of ancient and recent magmatic products provide strong constraints on the dynamics of magma oceans and crustal formation, and the longevity and evolution of interior heat engines and distinct mantle/crustal source regions. Absolute dating also relates habitability markers to the timescale of evolution of life on Earth. The number of geochronologically-significant terrains across the inner Solar System far exceeds our ability to conduct sample return to all of them. Therefore NASA has invested in the development of in situ dating techniques; several such instruments will be TRL 6 by the time of the next Decadal Survey. We formulated a set of medium-class (New Frontiers) mission concepts to three different locations (the Moon, Mars, and Vesta) with a notional payload consisting of the CDEX and KArLE instruments to measure radiometric ages, an imaging spectrometer and optical cameras to provide site geologic context and sample characterization, an ICP-MS to augment sample contextualization, and a sample acquisition and handling system. A Vesta hopper and single-site lunar and Mars landers to advance Solar System chronology fit into the New Frontiers cost cap in our study. Such missions would also enable a broad suite of geologic investigations such as basic geologic characterization, geomorphologic analysis, establishing ground truth for remote sensing analyses, analyses of major, minor, trace, and volatile elements, atmospheric and other long-lived monitoring, organic molecule analyses, and soil and geotechnical properties.

Barbara A Cohen↗

MO-FG-BRA-01: 4D Monte Carlo Simulations for Verification of Dose Delivered to a Moving Anatomy

Purpose: To validate 4D Monte Carlo (MC) simulations of dose delivery by an Elekta Agility linear accelerator to a moving phantom. Methods: Monte Carlo simulations were performed using the 4DdefDOSXYZnrc/EGSnrc user code which samples a new geometry for each incident particle and calculates the dose in a continuously moving anatomy. A Quasar respiratory motion phantom with a lung insert containing a 3 cm diameter tumor was used for dose measurements on an Elekta Agility linac with the phantom in stationary and moving states. Dose to the center of tumor was measured using calibrated EBT3 film and the RADPOS 4D dosimetry system. A VMAT plan covering the tumor was created on the static CT scan of the phantom using Monaco V.5.10.02. A validated BEAMnrc model of our Elekta Agility linac was used for Monte Carlo simulations on stationary and moving anatomies. To compare the planned and delivered doses, linac log files recorded during measurements were used for the simulations. For 4D simulations, deformation vectors that modeled the rigid translation of the lung insert were generated as input to the 4DdefDOSXYZnrc code as well as the phantom motion trace recorded with RADPOS during the measurements. Results: Monte Carlo simulations and film measurements were found to agree within 2mm/2% for 97.7% of points in the film in the static phantom and 95.5% in the moving phantom. Dose values based on film and RADPOS measurements are within 2% of each other and within 2σ of experimental uncertainties with respect to simulations. Conclusion: Our 4D Monte Carlo simulation using the defDOSXYZnrc code accurately calculates dose delivered to a moving anatomy. Future work will focus on more investigation of VMAT delivery on a moving phantom to improve the agreement between simulation and measurements, as well as establishing the accuracy of our method in a deforming anatomy. This work was supported by the Ontario Consortium of Adaptive Interventions in Radiation Oncology (OCAIRO), funded by the Ontario Research Fund Research Excellence program.

60 APPLIED LIFE SCIENCES↗

Intermunicipal cooperation, privatization and waste management costs: Evidence from rural municipalities

The aim of this paper is to analyze the effects of intermunicipal cooperation and privatization on the delivery costs of urban solid waste services in rural environments. The results of our empirical analysis, which we conducted among a sample of very small municipalities, indicate that small towns that cooperate incur lower costs for their waste collection service. Cooperation also raises collection frequency and improves the quality of the service in small towns. By contrast, the form of production, whether it is public or private, does not result in systematic differences in costs. Interestingly, the degree of population dispersion, that is, the number of population units within the municipal jurisdiction, has a significant positive relation with service costs. No evidence of scale economies is found because small municipalities have likely exploited them by means of intermunicipal cooperation.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The role of intergenerational influence in waste education programmes: The THAW project

Highlights: > Children can be effective advocates in changing their parents' lifestyles. > We investigated the role of intergenerational influence in waste education programmes. > Waste Watch's Take Home Action on Waste project worked with 6705 children in 39 schools. > The results showed increased participation in recycling and declines in residual waste. > The study shows that recycling behaviour is positively impacted by intergenerational influence. - Abstract: Whilst the education of young people is often seen as a part of the solution to current environmental problems seeking urgent attention, it is often forgotten that their parents and other household members can also be educated/influenced via home-based educational activities. This paper explores the theory of intergenerational influence in relation to school based waste education. Waste Watch, a UK-based environmental charity ((www.wastewatch.org.uk)), has pioneered a model that uses practical activities and whole school involvement to promote school based action on waste. This methodology has been adopted nationally. This paper outlines and evaluates how effective school based waste education is in promoting action at a household level. The paper outlines Waste Watch's 'Taking Home Action on Waste (THAW)' project carried out for two and half years in Rotherham, a town in South Yorkshire, England. The project worked with 6705 primary age children in 39 schools (44% of primary schools in the project area) to enable them to take the 'reduce, reuse and recycle message' home to their families and to engage these (i.e. families) in sustainable waste management practices. As well as substantial increases in students' knowledge and understanding of waste reduction, measurement of the impact of the project in areas around 12 carefully chosen sample schools showed evidence of increased participation in recycling and recycling tonnages as well as declining levels of residual waste. Following delivery of the project in these areas, an average increase of 8.6% was recorded in recycling set out rates which led to a 4.3% increase in paper recycling tonnages and an 8.7% increase in tonnages of cans, glass and textiles collected for recycling. Correspondingly, there was a 4.5% fall in tonnages of residual waste. Waste Watch's THAW project was the first serious attempt to measure the intergenerational influence of an education programme on behaviour at home (i.e. other than schools' own waste). It clearly shows that household recycling behaviour can be positively impacted by intergenerational influence via a practical school-based waste education model. However, although the model could potentially have a big impact if rolled out nationally, it will require seed funding and the long-term durability of the model has not yet been fully quantified.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

TU-FG-BRB-06: A Prompt Gamma-Ray Spectroscopy System for Clinical Studies of in Vivo Proton Range Verification

Purpose: We present a new system to perform prompt gamma-ray spectroscopy during proton pencil-beam scanning treatments, which enables in vivo verification of the proton range. This system will be used for the first clinical studies of this technology. Methods: After successful pre-clinical testing of prompt gamma-ray spectroscopy, a full scale system for clinical studies is now being assembled. Prompt gamma-rays will be detected during patient treatment using an array of 8 detector modules arranged behind a tungsten collimator. Each detector module consists of a lanthanum(III) bromide scintillator, a photomultiplier tube, and custom electronics for stable high voltage supply and signal amplification. A new real-time data acquisition and control system samples the signals from the detectors with analog-to-digital converters, analyses events of interest, and communicates with the beam delivery systems. The timing of the detected events was synchronized to the cyclotron radiofrequency and the pencil-beam delivery. Range verification is performed by matching measured energy- and timeresolved gamma-ray spectra to nuclear reaction models based on the clinical treatment plan. Experiments in phantoms were performed using clinical beams in order to assess the performance of the systems. Results: The experiments showed reliable real-time analysis of more than 10 million detector events per second. The individual detector modules acquired accurate energy- and time-resolved gamma-ray measurements at a rate of 1 million events per second, which is typical for beams delivered with a clinical dose rate. The data acquisition system successfully tracked the delivery of the scanned pencil-beams to determine the location of range deviations within the treatment field. Conclusion: A clinical system for proton range verification using prompt gamma-ray spectroscopy has been designed and is being prepared for use during patient treatments. We anticipate to start a first clinical study in the near future. This work was supported by the Federal Share of program income earned by Massachusetts; General Hospital on C06-CA059267, Proton Therapy Research and Treatment Center.

60 APPLIED LIFE SCIENCES↗

SPION@APTES@FA-PEG@Usnic Acid Bionanodrug for Cancer Therapy

In this work, we aimed to develop stable usnic acid (UA)-conjugated superparamagnetic iron oxide nanoparticles (SPIONs) as a potential drug carrier for in vitro analysis of MCF-7 (breast cancer cell line), HeLa (cervix cancer cell line), L929 (mouse fibroblast cell line), U87 (glioblastoma cell line, brain cancer), and A549 (human lung cancer cell line) cell lines. SPIONs were synthesized via the polyol method and functionalized with APTES using the Stöber method. Carboxylated polyethylene glycol (PEG-COOH), folic acid (FA), and carboxylated luteolin (CL) were conjugated on the surface via a carboxylic/amine group using the nanoprecipitation method, respectively. X-ray powder diffraction analysis confirmed the purity of the product with crystallite size of around 11 nm. Fourier-transformed infrared spectrophotometer (FT-IR) analyses explained the conjugation of all functional groups to the surface of SPIONs. The percentages of inorganic and organic content in the products were investigated via thermal gravimetric analyzer (TGA). For morphological analysis, a transmission electron microscope (TEM) was used. The superparamagnetic property of the product was also confirmed by vibrating sample magnetometer (VSM).

60 APPLIED LIFE SCIENCES↗

Endohedral confinement of a DNA dodecamer onto pristine carbon nanotubes and the stability of the canonical B form

Although carbon nanotubes are potential candidates for DNA encapsulation and subsequent delivery of biological payloads to living cells, the thermodynamical spontaneity of DNA encapsulation under physiological conditions is still a matter of debate. Using enhanced sampling techniques, we show for the first time that, given a sufficiently large carbon nanotube, the confinement of a double-stranded DNA segment, 5′-D({sup *}CP{sup *}GP{sup *}CP{sup *}GP{sup *}AP{sup *}AP{sup *}TP{sup *}TP{sup *}CP{sup *}GP{sup *}CP{sup *}G)-3′, is thermodynamically favourable under physiological environments (134 mM, 310 K, 1 bar), leading to DNA-nanotube hybrids with lower free energy than the unconfined biomolecule. A diameter threshold of 3 nm is established below which encapsulation is inhibited. The confined DNA segment maintains its translational mobility and exhibits the main geometrical features of the canonical B form. To accommodate itself within the nanopore, the DNA's end-to-end length increases from 3.85 nm up to approximately 4.1 nm, due to a ∼0.3 nm elastic expansion of the strand termini. The canonical Watson-Crick H-bond network is essentially conserved throughout encapsulation, showing that the contact between the DNA segment and the hydrophobic carbon walls results in minor rearrangements of the nucleotides H-bonding. The results obtained here are paramount to the usage of carbon nanotubes as encapsulation media for next generation drug delivery technologies.

97 MATHEMATICS AND COMPUTING↗