Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “retrofit design”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Passive Porous Treatment for Reducing Flap Side-Edge Noise

A passive porous treatment has been proposed as a means of suppressing noise generated by the airflow around the side edges of partial-span flaps on airplane wings when the flaps are extended in a high-lift configuration. The treatment proposed here does not incur any aerodynamic penalties and could easily be retrofit to existing airplanes. The treatment could also be applied to reduce noise generated by turbomachinery, including wind turbines. Innovative aspects of the proposed treatment include a minimum treatment area and physics-based procedure for treatment design. The efficacy of the treatment was confirmed during wind-tunnel experiments at NASA Ames, wherein the porous treatment was applied to a minute surface area in the vicinity of a flap edge on a 26-percent model of Boeing 777-200 wing.

Choudhari, Meelan M.↗

Simulating the Response of a Composite Honeycomb Energy Absorber: Dynamic Crushing of Components and Multi-Terrain Impacts - Part 1

This paper describes the experimental and analytical evaluation of an externally deployable composite honeycomb structure that is designed to attenuate impact energy during helicopter crashes. The concept, designated the Deployable Energy Absorber (DEA), utilizes an expandable Kevlar (Registered Trademark) honeycomb to dissipate kinetic energy through crushing. The DEA incorporates a unique flexible hinge design that allows the honeycomb to be packaged and stowed until needed for deployment. Experimental evaluation of the DEA included dynamic crush tests of multi-cell components and vertical drop tests of a composite fuselage section, retrofitted with DEA blocks, onto multi-terrain. Finite element models of the test articles were developed and simulations were performed using the transient dynamic code, LSDYNA (Registered Trademark). In each simulation, the DEA was represented using shell elements assigned two different material properties: Mat 24, an isotropic piecewise linear plasticity model, and Mat 58, a continuum damage mechanics model used to represent laminated composite fabrics. DEA model development and test-analysis comparisons are presented.

Jackson, Karen E.↗

Modeling Green Roof Potential to Mitigate Urban Flooding in a Chinese City

The Middle and Lower Reaches of the Yangtze River (MLRYR) region, which has humid subtropical climate conditions and unique plum rain season, is characterized by a simultaneous high-frequency urban flooding and reduction in groundwater levels. Retrofitting the existing buildings into green roofs is a promising approach to combat urban flooding, especially for a densely developed city. Here, the application potential of the Green Roof System (GRS) and the Improved Green Roof System (IGRS) designed to divert overflowing water from green roofs to recharge groundwater were analyzed in a densely developed city, Nanchang, China. For the first time, the influence of GRS on the hydraulic condition of Combined Sewage System/Storm Water System (CSS/SWS) is analyzed, which is a direct reflection of the effect of GRS on alleviating urban flooding. The simulation results show that GRS can retain about 41–75% of precipitation in a 2-hour timescale and the flooding volumes in the GRS/IGRS region are 82% and 28% less than those of the Traditional Roof System (TRS) in 10- and 100-yr precipitation events, respectively. In the continuous simulations, GRS also enhances Evapotranspiration (ET), which accounts for 39% of annual precipitation, so that reduces the cumulative surface runoff. Considering the IGRS can provide more hydrological benefits than the GRS under the same climate conditions, we may conclude that the widespread implementation of both the GRS and the IGRS in Nanchang and other densely developed cities in the MLRYR region could significantly reduce surface and peak runoff rates.

54 ENVIRONMENTAL SCIENCES↗

Study of cost/benefit tradeoffs for reducing the energy consumption of the commercial air transportation system

Economic studies were conducted for three general fuel conserving options: (1) improving fuel consumption characteristics of existing aircraft via retrofit modifications; (2) introducing fuel efficient derivations of existing production aircraft and/or introducing fuel efficient, current state-of-the-art new aircraft; and (3) introducing an advanced state-of-the-art turboprop airplane. These studies were designed to produce an optimum airline fleet mix for the years 1980, 1985 and 1990. The fleet selected accommodated a normal growth market by introducing somewhat larger aircraft while solving for maximum departure frequencies and a minimum load factor corresponding to a 15% investment hurdle rate. Fuel burnt per available-seat-mile flown would drop 22% from 1980 to 1990 due to the use of more fuel efficient aircraft designs, larger average aircraft size, and increased seating density. An inflight survey was taken to determine air traveler attitudes towards a new generation of advanced turboprops.

Coykendall, R. E.↗

Material Model Evaluation of a Composite Honeycomb Energy Absorber

A study was conducted to evaluate four different material models in predicting the dynamic crushing response of solid-element-based models of a composite honeycomb energy absorber, designated the Deployable Energy Absorber (DEA). Dynamic crush tests of three DEA components were simulated using the nonlinear, explicit transient dynamic code, LS-DYNA . In addition, a full-scale crash test of an MD-500 helicopter, retrofitted with DEA blocks, was simulated. The four material models used to represent the DEA included: *MAT_CRUSHABLE_FOAM (Mat 63), *MAT_HONEYCOMB (Mat 26), *MAT_SIMPLIFIED_RUBBER/FOAM (Mat 181), and *MAT_TRANSVERSELY_ANISOTROPIC_CRUSHABLE_FOAM (Mat 142). Test-analysis calibration metrics included simple percentage error comparisons of initial peak acceleration, sustained crush stress, and peak compaction acceleration of the DEA components. In addition, the Roadside Safety Verification and Validation Program (RSVVP) was used to assess similarities and differences between the experimental and analytical curves for the full-scale crash test.

Jackson, Karen E.↗

Dynamic Building Load Control to Facilitate High Penetration of Solar Photovoltaic Generation (Final Technical Report)

Solar photovoltaic (PV) resources are the most common form of distributed generation in residential and commercial customer premises within electric distribution networks. A higher penetration of PV generation in distribution circuits will impose challenges on maintaining service voltages within the range of industry standards, power quality, and power flow. Buildings consume 74% of the electricity produced in the United States, and a significant portion of the building load is dispatchable, making them responsive to electrical grid needs. Oak Ridge National Laboratory—in collaboration with Southern Company; the University of Tennessee, Knoxville; and the Georgia Institute of Technology—is examining the PV integration issues in distribution-level electrical grids and developing integrated demand-side control and communication systems to enable responsive loads. The proposed responsive loads mechanism performs renewable generation following to increase the penetration of solar PV within each feeder. The specific objectives of this project are to (1) examine distribution-level PV integration scenarios to understand requirements, (2) undertake an end-to-end simulation-based design of a distributed control strategy of loads geographically near the PV generation asset to minimize the effect on the distribution feeder, (3) deploy and demonstrate the control technology developed in partnership with utilities, and (4) perform a scalability analysis at the utility scale. This 3-year integrated project aims to develop, demonstrate, and validate demand-side control technology to enable increased the penetration of renewables while mitigating challenges that arise due to their intermittency. Activities in Budget Period (BP) 1 focused on a literature review and the formal design of a control system for integrating local distribution with generation and loads. The team used modeling and simulation to evaluate the impact of varying buildings loads, variable PV generation, and power flow dynamics on the distribution circuit. The dynamic models developed in BP 1 were used in BP 2 to develop a model-based control design and a test bed. The test bed has enabled the simulation-based testing and comparison of different control designs and formulations applied to different configurations of the distribution grid, PVs, and building loads. The control approaches developed in BP 2 were implemented in BP 3 in the form of hardware deployed at the Central Baptist Church (CBC) in Knoxville, Tennessee, for testing and evaluation. The outcome of this project was the development and demonstration of open-source, low-cost, low-touch sensing and control retrofits to distributed PV generation and building loads that, in a coordinated fashion, provide the load-shaping response needed to integrate high levels of renewable penetration. This research addresses the target metrics by dynamically controlling a load with solar generation variability to minimize the extent of two-way power flow, enhance reliability, facilitate high PV penetration (>100% of peak load in a line segment), and generate scalable software and hardware solutions adaptable to any penetration levels. The research and development activities are focused and designed to be impactful within the relevant 2020 targets time frame.An accurate open-source integration simulation framework for end-to-end control design was developed and deployed at the CBC facility for testing and evaluation. This final report provides a detailed review of the technical results achieved during this 3-year integrated project. A novel spectral analysis of PV data is demonstrated to derive the requirements of the control design. A detailed simulation-based analysis of PV integration at increasing penetration levels is presented using 1 year of PV data to demonstrate the impact on the distribution circuits. Two different control strategies were developed and demonstrated via simulation to track variable PV generation with adaptive load dispatch. The report concludes with a summary of accomplishments and recommendations for a path forward.

14 SOLAR ENERGY↗

Retrofitting Holcim Ste. Genevieve Cement Plant with CO2 Capture Plant Using Air Liquide Cryocap™ FG Technology

The global cement manufacturing industry is a major contributor to carbon dioxide emissions. The International Energy Agency's "Net Zero Emissions by 2050 Scenario" identifies CCS as a major strategy for meeting that goal. This project is among the first attempts to transfer capture technology developed at coal-fired power plants to the cement industry. The main objective of the project is to execute and complete a front-end engineering and design (FEED) studies for commercial-scale, carbon capture projects that separates 95% of the total CO2 emissions at the Holcim (US) Ste. Genevieve cement manufacturing facility using Air Liquide’s Pressure Swing Adsorption system (PSA) assisted Cryocap™ technology. The Holcim Ste. Genevieve cement plant in Missouri, US, boasts one of the largest single cement production lines in the world, with a capacity of approximately 12,000 t/day. The plant currently uses traditional fuels, namely coal and petcoke. The captured CO2 will be pipeline and geological storage grade. The industrial host site emits approximately 3.0 million tonne CO2/yr. Air Liquide’s Cryocap™ technology has been developed over the last 18+ years for CO2 capture applications. It has been shown to be applicable to a variety of industrial applications (e.g., steel, cement, SMR, Fluidized Catalytic Crackers (FCCs)). Cryocap™ FG consists of a Pressure Swing Adsorption (PSA) unit coupled with a Cryogenic System. The PSA pre-concentrates the CO2 from the flue gas, while the cryogenic unit enables the CO2 purity to be increased to the desired level. The project team is led by the Prairie Research Institute at the University of Illinois at Urbana-Champaign. The tasks include: complete FEED study for retrofitting the industrial facility with a carbon capture system to support developing a detailed cost estimate; business case analysis outlining the anticipated revenue and credits if projects was built and operated; technoeconomic analysis (TEA) outlining how capture system achieves DOE capture goals; and life cycle (LCA) analysis demonstrating zero net carbon emissions. The FEED study was successfully completed. This includes completing the process basis of design; preliminary engineering; outside battery limits (OSBL) detailed engineering including a Zero Liquid Discharge (ZLD) wastewater treatment system; inside battery limits (ISBL) detailed engineering [1]. An overall project capital cost estimate within a -20%/+30% accuracy was developed. The major contributors to the Total Plant Cost (TPC), by system, are the costs associated with the Outside Battery Limit (OSBL) section of the plant which includes a new river water intake structure and a Zero Liquid Discharge (ZLD) system. By cost category, the major contributors to the TPC are equipment and subcontractor costs, followed closely by engineering, construction management, home office and contractor fees. The TEA has been created to reflect the findings of the project. It analyzes the economic performance of the Cryocap™ technology by reviewing the estimated capital costs, operating cost, and revenue. The Cost of Capture (COC) associated with the Cryocap™ technology for 95% CO2 capture, when considering NETL 2018 economic assumptions (42/58 debt/equity ratio, 5.15% interest on debt and 1.42% return on equity in real dollars) and 2022 economic assumptions (42/58 debt/equity ratio, 8.82% interest on debt and 4.90% return on equity in real dollars) was found to be much lower than that for the DOE-NETL’s base-line cases. The highest contributors to the COC are annualized capital expenditures (CAPEX) and electricity consumption which can be offset by using lower cost renewable sources. The LCA was conducted using OpenLCA which is an open-source software that is recommended by NETL. The database utilized for this study was a modified version of TRACI 2.1 (developed by the US. Environmental Protection Agency’s National Risk Management Research Laboratory and modified by NETL). The Cryocap™ FG technology does not consume fuels in significant quantities and does not utilize specialized chemical solvents subject to decomposition, such as those utilized in amine-based carbon capture systems. The Cryocap™ FG technology mainly utilizes electricity as its energy input; hence, its calculated emissions are mainly associated with the generation of electricity offsite and are dependent on the energy matrix of the grid at the time of project implementation. The water consumption impact of the Cryocap™ FG is mostly for makeup of the water lost by evaporation in the cooling tower; however, the carbon capture plant will be equipped with a ZLD system to avoid effluent streams and minimize water consumption. The successful construction and operation of this plant based on this study results will provide a means to demonstrate an economically attractive and transformational capture technology that can be used to retrofit existing plants and be deployed at new plants.

01 COAL, LIGNITE, AND PEAT↗

TRANSENSOR: Transformer Real-time Assessment INtelligent System with Embedded Network of Sensors and Optical Readout. Final Report

Utilities across the world are wrestling with evolving market dynamics, population growth and climate change. Distributed Energy Resources (DERs) such as solar photovoltaics, distributed generators and energy storage systems are becoming important parts of the U.S. energy mix. These factors are driving an increasing need for low-cost grid asset monitoring. Aside from being costly, traditional utility monitoring systems are not sufficiently robust and do not provide real-time visibility into the condition of grid assets such as transformers. Lack of accurate real-time measurements on performance has resulted in the use of lagging indicators, such as oil sample analysis. To address this need, an innovative embedded optical sensing technology, Transformer Real-time Assessment Intelligent System (TRANSENSOR) was developed, validated and demonstrated in this project. To date, TRANSENSOR has focused on transformers but is extendable to other grid assets. In addition to the technology being embedded into new transformers during manufacturing, a retrofit configuration that can be installed on existing transformers in the field was also developed. It is anticipated that the ability to retrofit existing transformers will help accelerate adoption of the underlying TRANSENSOR technology. Phase 1 of the project focused on laboratory development and qualification of the technology. Following iterations and exploration of relevant optical sensing modalities and multiplexed configurations of interest for the transformer environment, an effective candidate configuration was agreed upon, down-selected and custom-designed for embedding into General Electric (GE) network transformers. Two new GE 500 kilovolt ampere (kVA), 27 kilovolt (kV) distribution network transformers were built with embedded fiber-optic (FO) sensors and successfully qualified per industry standards at GE’s Shreveport, Louisiana facility during Phase 1 of the project. Following the successful completion of Phase 1, the team proceeded to Phase 2, which focused on a field demonstration of the technology. Over Phase 2, the first new GE transformer built with embedded fiber-optic sensors was installed in an above-ground cage and connected to the grid at Con Edison’s Astoria facility. A second transformer equipped with TRANSENSOR was installed in an underground vault. Additionally, an older (1982 year model) GE transformer in an above-ground cage was retrofitted with fiber- optic sensors and reconnected to the grid at ConEd’s facility. Analysis of data acquired from the sensors showed interesting correlations with transformer loading. Additionally, key events such as transformer low-voltage network connection, primary-side energizing, and a pressure loss event from an oil sampling were detected by the TRANSENSOR system. Online data processing/feature extraction algorithms for the second transformer in the underground vault detected key features and event alerts that were transmitted through a wireless 4G connection. The remote deployment concept showed promising results with data collection running for a total of 8 months across the three (3) GE transformers instrumented for the Phase 2 field demonstration. This sets the stage well for further development and commercialization.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Technical Potential for Hydropower Capacity at Non-powered Dams

In the last decade, retrofits of existing nonpowered dams (NPDs) have made up the largest share of capacity increases for US hydropower. Accurate estimates of potential capacity and generation at NPDs help identify sites that may be worth investing in detailed feasibility analyses and design exploration. This dataset consists of NPDs in the conterminous US with at least 100kW of theoretical potential based on earlier resource assessments. Historical daily streamflow (modeled or from USGS gauge records), hydraulic head (based on historical observations or primary purpose and dam height) are the main inputs for HydroGenerate which determines design flow and turbine efficiencies and then calculates nominal capacity, daily generation, and capacity factor. These outputs are summarized on a monthly basis (i.e., generation (MWh) and capacity factor averaged for each month from January to December) and overall (i.e., nominal capacity, average annual generation (MWh), and average annual capacity factor). A total of 4.1 GW capacity is estimated across all 2,564 NPDs included in the dataset.

13 HYDRO ENERGY↗

Technical Potential for Hydropower Capacity at Non-powered Dams

In the last decade, retrofits of existing nonpowered dams (NPDs) have made up the largest share of capacity increases for US hydropower. Accurate estimates of potential capacity and generation at NPDs help identify sites that may be worth investing in detailed feasibility analyses and design exploration. This dataset contains estimates of technical potential capacity and generation at 2,616 NPDs in the conterminous US. This is based on a subset of dams that were found by earlier resource assessments to have at least 100kW of theoretical potential. Historical daily streamflow (modeled or from USGS gauge records) and hydraulic head (based on historical observations or primary purpose and dam height) are the main inputs to the HydroGenerate model, which determines design flow, turbine efficiencies, and assumed friction losses and then calculates nominal capacity, daily generation, and capacity factor. These estimates represent the conditions over the historical period of 1980-2015, and are summarized on a monthly basis (i.e., averaged for each month of the year) and overall (i.e., nominal capacity, average annual generation (MWh), and average annual capacity factor). A total of nearly 4 GW capacity is estimated across all 2,616 NPDs included in the dataset.

Hansen, Carly [Oak Ridge National Laboratory (ORNL↗

A Mechanical Test Frame for Property Evaluations at Cryogenic Temperature

On-board storage of hydrogen fuel has been designated as a limiting factor in the advancement of fuel cell technologies in the automotive industry. The use of cryo-compressed Type III pressure vessels presents one option to overcome this barrier. These multi-material vessels will be expected to perform at high pressure and extreme low temperatures, which creates a complex engineering design challenge. Many materials exhibit highly temperature-dependent properties, which must be considered for the efficient design of cryo-compressed pressure vessels. Complicating this issue, mechanical property data at cryogenic temperatures is sparse. This technical paper provides a description of a test apparatus commissioned specifically to help address this shortcoming. A mechanical test frame was retrofitted with a continuous flow cryostat capable to evaluate various mechanical properties throughout a broad temperature range of 25 °C to -269 °C with a load limit of 10 kN. An investigation of the thermomechanical properties of an epoxy resin was carried out as a demonstration.

Mechanical characterization, cryogenic pressure ve↗

Spinoff 2011

Topics include: Bioreactors Drive Advances in Tissue Engineering; Tooling Techniques Enhance Medical Imaging; Ventilator Technologies Sustain Critically Injured Patients; Protein Innovations Advance Drug Treatments, Skin Care; Mass Analyzers Facilitate Research on Addiction; Frameworks Coordinate Scientific Data Management; Cameras Improve Navigation for Pilots, Drivers; Integrated Design Tools Reduce Risk, Cost; Advisory Systems Save Time, Fuel for Airlines; Modeling Programs Increase Aircraft Design Safety; Fly-by-Wire Systems Enable Safer, More Efficient Flight; Modified Fittings Enhance Industrial Safety; Simulation Tools Model Icing for Aircraft Design; Information Systems Coordinate Emergency Management; Imaging Systems Provide Maps for U.S. Soldiers; High-Pressure Systems Suppress Fires in Seconds; Alloy-Enhanced Fans Maintain Fresh Air in Tunnels; Control Algorithms Charge Batteries Faster; Software Programs Derive Measurements from Photographs; Retrofits Convert Gas Vehicles into Hybrids; NASA Missions Inspire Online Video Games; Monitors Track Vital Signs for Fitness and Safety; Thermal Components Boost Performance of HVAC Systems; World Wind Tools Reveal Environmental Change; Analyzers Measure Greenhouse Gasses, Airborne Pollutants; Remediation Technologies Eliminate Contaminants; Receivers Gather Data for Climate, Weather Prediction; Coating Processes Boost Performance of Solar Cells; Analyzers Provide Water Security in Space and on Earth; Catalyst Substrates Remove Contaminants, Produce Fuel; Rocket Engine Innovations Advance Clean Energy; Technologies Render Views of Earth for Virtual Navigation; Content Platforms Meet Data Storage, Retrieval Needs; Tools Ensure Reliability of Critical Software; Electronic Handbooks Simplify Process Management; Software Innovations Speed Scientific Computing; Controller Chips Preserve Microprocessor Function; Nanotube Production Devices Expand Research Capabilities; Custom Machines Advance Composite Manufacturing; Polyimide Foams Offer Superior Insulation; Beam Steering Devices Reduce Payload Weight; Models Support Energy-Saving Microwave Technologies; Materials Advance Chemical Propulsion Technology; and High-Temperature Coatings Offer Energy Savings.

Source record↗

Cool rooms for indoor heat resilience: Evaluating affordable cooling strategies in heat-stressed California homes

Extreme heat conditions pose significant indoor survivability challenges for resource-constrained communities, which often lack access to cooling, have poorly insulated homes, and face compounding socioeconomic vulnerabilities. Moreover, concurrent power outages worsen health risks and heat-related illnesses. It is therefore crucial to develop innovative and affordable cooling approaches to protect vulnerable populations. This study assesses the efficacy of “cool rooms”– a designated space within a home equipped with passive and low-power active cooling measures to maintain safe indoor temperatures during extreme heat events and power disruptions. Using a physics-based building energy modeling approach, we evaluate the efficacy of various retrofit packages in maintaining thermal safety within the cool room under recent extreme heat conditions. The results indicate that passive measures can reduce 64% of hours with unmet standard effective temperatures, while the combination of passive and low-power active measures with built-in batteries further cuts this to 86%. Nevertheless, these strategies remain insufficient to maintain indoor thermal safety during extended outages. In contrast, integrating a solar-powered mini-split heat pump, whose technical potential was evaluated in this study, reduces indoor air temperatures below the 28 °C overheating threshold and significantly improves indoor habitability. The localized cool room strategy also offers potential for grid resilience by reducing peak electricity demand by up to 70% compared to whole house cooling during heat waves. The findings can inform the development of actionable heat mitigation plans and retrofit policies for residential communities with relatively low adoption of air conditioning such as warm marine climates.

Cool room↗

Strategies for Residential Energy Efficiency and Community Resilience for Floyd County, Kentucky

This report outlines the technical assistance provided to Floyd County Fiscal Court, Kentucky, and Vision Granted through the U.S. Department of Energy Clean Energy to Communities Expert Match Program. Floyd County, designated as “distressed” and “disadvantaged,” faces significant economic challenges, including limited job prospects, high energy costs, and youth “brain drain.” This technical assistance aims to address these pressing issues by implementing strategies to enhance home energy efficiency and livability while also aligning retrofit efforts with goals for resilience and workforce development. Through targeted guidance, this report aims to empower Floyd County residents and organizations in navigating resources for improving housing conditions, creating workforce opportunities, and enhancing resilience.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Green-Field Geothermal/Solar Designs (Cooperative Research and Development Final Report)

Geothermal power (GEO) and concentrating solar power (CSP) can be integrated to obtain the best aspects of both systems. The green-field design will utilize the full potential of the higher-temperature CSP sector by having a topping solar steam turbine and a bottoming geothermal cycle. In the proposed hybrid cycle, geothermal energy can be converted into electricity at a higher cycle efficiency because of the high-temperature topping cycle during the daytime. CSP benefits from lower-cost solar collectors, a less expensive topping turbine, and virtual elimination of the heat rejection system cost. The green-field case study will be focused on a geothermal resource site which will deliver the 160 - 220 °C pressurized brine at the inlet of power block. While the case study will look at a single case study, the tools to be developed as part of the project will be available to model annual performance of GEO/CSP hybrids for new greenfield projects (may also be applied to certain types of brown-field retrofits). The evaluation tools will also calculate important economic parameters such as the levelized cost of energy (LCOE) and the internal rate of return (IRR).

14 SOLAR ENERGY↗

Design definition of a microwave power reception and conversion system for use on a high altitude powered platform

The design definition of a microwave power reception and conversion system for use on high altitude powered platform is presented. The study includes an initial design, construction and test effort on a thin film, printed circuit rectenna. A study of a low altitude demonstration of an airborne rectenna was made starting with the assumption that a fifty foot mechanically steerable parabolic reflector at the Wallops Flight Center would be retrofitted with a low microwave power source consisting of a five kilowatt commercially available magnetron and that a small blimp would be used to support the rectenna.

W. C. Brown↗

Extending Component Lifetime And Improving Inverter Reliability (ECLAIIR)

Inverter reliability remains one of the most persistent challenges limiting the performance, availability, and economic viability of utility‑scale photovoltaic (PV) plants. Industry data consistently show that inverters account for the highest share of corrective maintenance events and unplanned outages across PV fleets. These failures result in energy losses, increased O&M costs, and reduced confidence in long‑term solar asset performance. Motivated by these challenges, this project—Extending Component Lifetime and Improving Inverter Reliability (ECLAIIR)—was undertaken to systematically investigate inverter degradation and failure mechanisms, develop predictive maintenance capabilities, and establish data‑driven pathways to improve service life and reduce the Levelized Cost of Energy (LCOE) for large‑scale PV systems. The primary goal of the project was to identify pre‑failure signatures in string inverters using both lab‑based accelerated lifetime testing and field‑based data and to develop predictive maintenance algorithms that can anticipate inverter faults before they occur. Through collaboration with inverter testing laboratory, solar PV plant owner, and failure‑analysis experts, the project advanced the technical understanding of inverter reliability. By instrumenting inverters with thermistors, humidity sensors, power‑quality meters, and acoustic sensors, the research established how multiple sensing modalities can reliably detect deviations from normal behavior hours to days before failure. These findings substantially enhance scientific understanding of inverter failure kinetics and provide the PV industry with the most comprehensive cross‑OEM characterization of early‑stage failure indicators reported to date. Technically, the project demonstrated the effectiveness of predictive maintenance by developing and validating the PreDICT (Predictive Diagnostics of PV Inverters Using Condition Monitoring and Trend Analysis) framework—a multi‑layer diagnostic architecture combining peer‑to‑peer analytics, historical trend modeling, and advanced machine‑learning techniques such as the Sequential Conditional Variational Autoencoder (SCVAE). This predictive model achieved more than 90% accuracy in detecting pre‑failure conditions and provided up to four days of lead time before inverter failure in field scenarios. Economically, the project’s LCOE analysis showed that predictive maintenance can reduce lifetime energy losses and minimize corrective maintenance interventions. Modeling indicated that, depending on inverter failure rates and replacement timelines, predictive maintenance can significantly reduce LCOE impacts associated with inverter downtime: from as high as 19.4% under conventional maintenance strategies to 0.1%–10.17% when predictive analytics are adopted. These results confirm that predictive maintenance is both technically feasible and economically advantageous for utilities and plant operators. The project’s findings also have broad public benefit. By improving inverter reliability and reducing downtime, predictive maintenance directly increases electricity generation from existing PV assets. Enhanced reliability lowers operational costs for utilities, which can translate over time into lower energy costs for consumers. Furthermore, the project’s technical publications, conference presentations, and industry workshops ensure that knowledge gained is shared broadly across the solar industry, supporting workforce development and enabling utilities of all sizes to adopt modern asset‑health monitoring practices. The retrofitting case study and service‑life prediction framework further support informed decision‑making for aging PV fleets, helping operators extend system life and reduce electronic waste. In summary, the ECLAIIR project significantly advanced the state of knowledge on inverter degradation, demonstrated the technical and economic value of predictive maintenance, and delivered actionable tools and insights that support more reliable, cost‑effective, and sustainable PV plant operation. The outcomes of this project will continue to inform utility practices, guide inverter design improvements, and strengthen the long‑term performance of solar assets nationwide.

14 SOLAR ENERGY↗

Automated longwall guidance and control vertical control subsystem, volume 1

A design, fabrication, and implementation of a horizon control of a longwall shearer was performed. This equipment was tested and demonstrated aboveground. This hardware was also installed on a longwall face. The feasibility of providing horizon control for a shearer was demonstrated aboveground. The feasibility of retrofitting the necessary sensors in a survivable manner was demonstrated underground. Subsequent field tests of a specific component, the natural background sensor, at a western location demonstrated the particular usefulness of this device on a wider application basis.

Griffiths, W. R.↗