Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “refrigerators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Enhanced magnetocaloric performance in manganite bilayers

Bilayer films of La 0.8 Sr 0.2 MnO 3 and La 0.7 Ca 0.3 MnO 3 with different layer thicknesses and stacking sequences were synthesized via pulsed laser deposition. The magnetic properties and magnetocaloric effects were systematically investigated. We found that the phase transition associated with the layers tends to merge together at an optimal thickness and a stacking sequence. The operating temperature span of the entropy change broadens at the expense of its magnitude, leading to an enhancement of the refrigerant capacity by over 40%. The optimized bilayer film possesses a refrigerant capacity of ~6.0J/kg, compared to a value of ~4.2J/kg for the single-phase films. The phase transition broadening induced by epitaxial strain is responsible for the enhanced window of operating temperature as well as refrigerant capacity. Finally, the design principle developed here may be applied to ferroelastic and ferroelectric materials to enhance elastocaloric and electrocaloric effects.

36 MATERIALS SCIENCE↗

building-physics/refrigeration-system

The existing refrigeration system for OpenStudio was originally designed for a prototype supermarket model. To support the development of new modular space types, it is crucial to refactor the system. This process includes refining the design by utilizing the manufacturer's existing data, along with incorporating the latest data from manufacturers, to enhance the system’s adaptability and functionality. This repository currently contains the refrigeration system database and Python-based automation for generating OpenStudio-compatible refrigeration JSON files.

Bae, Yeonjin [Oak Ridge National Laboratory (ORNL)↗

Electrohydrodynamic Enabled Electrochemical Membrane Dehumidifier for Separate Sensible and Latent Cooling

In hot and humid parts of the world, air conditioning is a necessity for an adequate standard of living. Cooling and heating represent one-third of building energy consumption. When cooling humid air, a substantial amount of the cooling energy is absorbed by water vapor condensation. The dehumidification cooling load is referred to as the latent cooling load and the dry bulb cooling load is referred to as the sensible cooling load. In most residential applications, the total cooling load is processed by a vapor compression cycle. Processing the latent load separately would not only reduce energy consumption. It would also reduce the required refrigeration capacity. Refrigerants often have adverse ecological impacts, contributing to the greenhouse effect and depletion of the ozone layer. Reduction of the cooling capacity in a system could reduce the amount of refrigerant charge required.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development of Carbon Molecular Sieves Hollow Fiber Membranes based on Polybenzimidazole Doped with Polyprotic Acids with Superior H 2 /CO 2 Separation Properties (Final Report)

The goal of this project was to develop a highly efficient membrane-based process to capture CO 2 from coal-derived syngas with 95% CO 2 purity, achieving the cost of electricity (COE) 30% below the baseline capture approaches (i.e., Selexol process) when coupled with the advancement in other areas of the power generation facility. Our core approach is based on high-permeance hollow fiber membranes (HFMs) with superior H 2 /CO 2 separation properties at the syngas process conditions, which can then be further utilized to design membrane reactors for process intensification of H 2 production and purification and CO 2 capture. Three organizations with complementary skills collaborated to achieve the goal, including the University at Buffalo (UB), Los Alamos National Laboratory (LANL), and Trimeric Corporation (Trimeric). We formulated logical steps to bring the membrane technology from Technology Readiness Level (TRL) 3 (Experimental proof of concept) to TRL 4 (Laboratory scale validation in relevant environment). During the budget period (BP) 1, we screened various polymeric materials and identified polybenzimidazole doped with inorganic polyprotic acids as the desirable platform. The acid doping increases the H 2 /CO 2 selectivity, and the sequential carbonization increases H 2 permeability while retaining the high selectivity. By manipulating the acid type and doping level and the carbonization temperature, we demonstrated advanced carbon molecular sieving (CMS) materials with H 2 permeability of above 200 Barrer (1 Barrer = 10 -10 cm 3 (STP) cm cm -2 s -2 cmHg -1 ) and H 2 /CO 2 selectivity of above 40 at 200-300°C with simulated syngas containing CO and water vapor. For example, the PBI-(H 3 PO 4 ) 0.11 carbonized at 700 °C exhibits H 2 permeability of 200 Barrer and H 2 /CO 2 selectivity of 60 at 200 °C, and H 2 permeability of 240 Barrer and H 2 /CO 2 selectivity of 54 at 225 °C, which meets the targeted properties and surpasses Robeson’s upper bound. During the BP2, we focused on the conversion of the advanced CMS materials to stable HFMs. Membranes with H 2 permeance of 1,090 GPU (1 GPU = 10 -6 cm 3 (STP) cm -2 s -2 cmHg -1 ) and H 2 /CO 2 selectivity of 57 at 300 °C were successfully fabricated. The effects of temperature, gas compositions, pressure, and time on the separation properties were systematically investigated. Pencil modules were continuously evaluated for 219 h (dry pure gas) and 669 h (dry simulated syngas) and showed initial decline in permeance and increased H 2 /CO 2 selectivity over time, ultimately achieving a steady state stable value, indicating that the ageing phenomena in the nanoporous structures of the membranes during the test. Membrane reactors were fabricated based on the CMS membranes and evaluated for water-gas shift (WGS) reaction. The use of membranes slightly improves the conversion of the CO. However, parametric tests of the membrane reactors at various temperatures and flow rates need to be conducted, as well as the membranes with improved separation performance. We performed a sensitivity analysis on the impact of H 2 /CO 2 selectivity on the COE based on a hybrid process of a membrane unit and cryogenic unit developed by Membrane Technology and Research, Inc. (MTR). Three H 2 /CO 2 selectivity (40, 60, and 15) cases were developed and compared with the baseline capture process (Case B5B) provided by the DOE report. Increasing the membrane H 2 /CO 2 selectivity reduces COE, but the rate of the decrease of COE also diminishes. The COE values for H 2 /CO 2 selectivities of 40 and 60 were nearly the same. As the H 2 /CO 2 selectivity increases, the inert recycling decreases, leading to smaller equipment, less auxiliary power requirements, and less heating, cooling, and refrigeration duty. The refrigeration system used to liquefy the CO 2 is the most expensive piece of equipment and consumes the most electricity within the CO 2 capture process. Increasing the CO 2 concentration in the recycle stream would improve the economics of the process by reducing the refrigeration duty requirement of the unit and also allow for higher liquefaction temperatures. The high H 2 -selective membrane developed by our team may be applicable in other separation processes where lower pressure H 2 retains value. Typically, hydrogen retains its pressure when it is separated from syngas components. Residual components may be used as low-quality fuel and then vented to the atmosphere. Applications might include control of H 2 /CO ratios or mitigation of the water gas shift reaction by CO 2 recycling to the feed of a gasifier or steam methane reformer. To summarize, we have developed industrial HFMs with the best H 2 /CO 2 separation performance reported in the literature. The membranes demonstrate stability with simulated syngas and show great potential for membrane reactors for WGS reactions, lowering the cost of blue H 2 production.

20 FOSSIL-FUELED POWER PLANTS↗

Low Carbon Development Pathways for Cooling: Leveraging Kigali Amendment Across Residential Applications

Heating and cooling demand for space conditioning and refrigeration accounts for around a fifth of global final energy consumption. Climate change, urbanisation, and economic development have tripled electricity demand for cooling alone since the 1990s, with the majority coming from the use of inefficient cooling equipment, which burdens electricity grids, especially during the peak hours. It is imperative to address the energy required to provide cooling. The Kigali Amendment to the Montreal Protocol addresses these needs by setting ambitious global targets to phase down refrigerants with high global warming potential, while improving energy efficiency. Integrating energy efficiency and the refrigerant transition will contribute to economic security, well-being, energy access and security, and sustainability among the G20 countries.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

High performance heat exchangers for next generation hybrid cooler (CRADA NFE-19-07891 Final Report)

The evaporative cooling process has been successfully deployed in multiple energy conversion processes such as power generation, process cooling, heating, ventilation & cooling (HVAC), and commercial and industrial refrigeration. The heat exchanger is a very common yet extremely critical component of such systems. The device is important since the performance of the overall cooling system heavily relies on the thermal-hydraulic efficiency of the heat exchanger. The possible wet operation as evaporative cooling heat exchanger complicates the issue. Indeed, based on the hybrid nature of operation (fully dry, partially wet, fully wet) the efficiency can vary significantly and can cause performance variation for the whole system. Understanding the importance of the issue, Oak Ridge National Laboratory (Contractor) and Baltimore Aircoil Company (Participant) propose an activity focused on the analysis of the existing heat exchanger technology used in air and evaporative cooling processes and design, development and demonstration of a novel heat exchanger design based on porous materials. The potential candidates include metallic wire meshes and metal foams carefully designed for the proposed application. Prior research has indicated that these materials have great potential for deployment in thermal systems, particularly heat sinks and heat exchangers. It is expected that the successful completion of the project will lead to novel heat exchanger technology for hybrid systems (capable of dry and wet operation) by exploring newly emerging materials and their potential for heat transfer application. The overall goal is to develop a next generation heat exchanger technology which can be deployed in evaporative cooling systems. The impact of the such development is significant since, it will not only make the overall system highly efficient but will also, reduce the total refrigerant charge in the heat exchanger, a critical aspect for the deployment of refrigerants with lower Global Warming Potential (GWP).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

High performance heat exchangers for next generation hybrid cooler (CRADA Final Report)

The evaporative cooling process has been successfully deployed in multiple energy conversion processes such as power generation, process cooling, heating, ventilation & cooling (HVAC), and commercial and industrial refrigeration. The heat exchanger is a very common yet extremely critical component of such systems. The device is important since the performance of the overall cooling system heavily relies on the thermal-hydraulic efficiency of the heat exchanger. The possible wet operation as evaporative cooling heat exchanger complicates the issue. Indeed, based on the hybrid nature of operation (fully dry, partially wet, fully wet) the efficiency can vary significantly and can cause performance variation for the whole system. Understanding the importance of the issue, Oak Ridge National Laboratory (Contractor) and Baltimore Aircoil Company (Participant) propose an activity focused on the analysis of the existing heat exchanger technology used in air and evaporative cooling processes and design, development and demonstration of a novel heat exchanger design based on porous materials. The potential candidates include metallic wire meshes and metal foams carefully designed for the proposed application. Prior research has indicated that these materials have great potential for deployment in thermal systems, particularly heat sinks and heat exchangers. It is expected that the successful completion of the project will lead to novel heat exchanger technology for hybrid systems (capable of dry and wet operation) by exploring newly emerging materials and their potential for heat transfer application. The overall goal is to develop a next generation heat exchanger technology which can be deployed in evaporative cooling systems. The impact of the such development is significant since, it will not only make the overall system highly efficient but will also, reduce the total refrigerant charge in the heat exchanger, a critical aspect for the deployment of refrigerants with lower Global Warming Potential (GWP).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Compressor is A Sensor (Final Report)

The performance of the heat pump system varies greatly depending on the refrigerant charge amount. Improving the refrigerant charge fault detection and diagnostics (FDD) method of vapor compression systems have the potential for increasing energy efficiency and reducing service cost. Previous studies to predict refrigerant charge amount are mostly empirical methods which require significant amount of experimental data for high accuracy. The primary goal of this research is to develop a charge fault detection method which requires only a few experimental data with high prediction accuracy.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Advanced Frost Sensor for HVAC Applications

Frost is a common problem in heating, ventilation, and air conditioning (HVAC) systems that can degrade their efficiencies, leading to excessive electricity consumption. Appropriate defrosting is therefore essential for heat pumps and refrigeration systems. However, these systems typically run the defrost cycle based on a predetermined time interval, a method that does not accurately identify the amount of frost and thus consume excessive electricity. To substantially improve defrosting initiation and termination, this paper describes development of a smart sensor based on a capacitive sensing technique that can quantify frost accumulation and difference between frost, ice, and water. The reported sensor adopts interdigitated comb electrodes and can be updated to a potential multifunctional sensor array for the enhancing identification of frost, ice, and water with the integrated measurement of surface temperature, frost capacitance, and resistance. The proposed frost sensor is potentially expected to have widespread applications in HVAC systems, including heat pumps, refrigerators, and commercial refrigeration systems.

Gao, Zhiming↗

Performance Enhancement of the Transcritical CO2 Cycle with a Near-Isothermal Liquid Piston Compression by an Ejector

This study investigates the use of an ejector in a transcritical CO2 cycle employing a near-isothermal liquid piston compressor, with the objective of mitigating refrigerant degassing in mineral oil. While the liquid piston compressor demonstrated high isothermal efficiency (˜90%), overall cycle performance was limited by CO2 degassing during chamber pressure fluctuations. A thermodynamic model was developed to compare baseline and ejector-assisted cycles, incorporating solubility correlations, entrainment ratio characteristics, and a degassing correction factor. Results indicate that the ejector increased suction pressure and reduced CO2–oil solubility variation, which improved refrigerant intake and reduced degassing losses. Despite these benefits, the ejector-assisted cycle showed a lower coefficient of performance (COP) than the baseline. Possible contributing factors include the limited marginal benefit of pressure reduction in a highly efficient isothermal compressor, reduced effectiveness of the separator due to the use of a suction-line heat exchanger in both cycles, and uncertainties in the solubility data under transient conditions. These findings suggest that degassing mitigation is essential for realizing the potential of liquid piston compression, but ejector integration alone is unlikely to enhance COP. Future work should focus on ejector optimization, improved oil–refrigerant management, introducing less-soluble working liquids, and experimental validation under realistic operating conditions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Component and efficient plate and frame absorber

An absorber for an absorption refrigeration system for a vertically mounted plate absorber has fins positioned over the plate to promote distribution of a fluid under flow as a nearly continuous thin film. The absorber has rows of fins that are evenly spaced with the fins occupying a portion of the active width of the plate with adjacent rows offset by the width of the plate. A combined evaporator-absorber module is constructed with the absorbing face of the absorber parallel with an evaporating surface of an evaporator where absorber solution and refrigerant fall as parallel falling sheets of liquid. The absorber is covered with a porous hydrophobic membrane to isolate the falling absorber solution from the falling liquid refrigerant.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Adsorption cooling system using metal organic frameworks

A highly adsorptive structure, includes: a substrate; and a metal-organic framework (MOF) comprising a plurality of metal atoms coordinated to a plurality of organic spacer molecules; wherein the MOF is coupled to at least one surface of the substrate, wherein the MOF is adapted for adsorbing and desorbing a refrigerant under predetermined thermodynamic conditions. The refrigerant includes one or more materials selected from the group consisting of: acid halides, alcohols, aldehydes, amines, chlorofluorocarbons, esters, ethers, fluorocarbons, perfluorocarbons, halocarbons, halogenated aldehydes, halogenated amines, halogenated hydrocarbons, halomethanes, hydrocarbons, hydrochlorofluorocarbons, hydrofluoroethers, hydrofluoroolefins, inorganic gases, ketones, nitrocarbon compounds, noble gases, organochlorine compounds, organofluorine compounds, organophosphorous compounds, organosilicon compounds, oxide gases, refrigerant blends and thiols.

Baumann, Theodore F.↗

Integration of Thermoelectric Modules to Vapor Compression Systems

This paper describes the technology of a thermoelectric (TE) integrated heat pump. It uses a TE heat pump to subcool the refrigerant liquid before entering the evaporator to enlarge the evaporating capacity; and elevate the heat in the refrigerant flow to a supplemental heating coil and discharge the capacity to the indoor air flow. Using the DOE/ORNL Heat Pump Design Model, four system configurations were modelled on a baseline two-speed heat pump, the baseline heat pump with adding a supplemental coil, the TE integrated heat pump having one stage TE heating to control a 20R liquid refrigerant temperature drop; and having two stages TE heating to control up to 40R temperature drop. The system models were used to produce performance curves for EnergyPlus building energy simulations. We selected template residential buildings, poorly insulated: pre-1990 buildings, and well-insulated: IECC2021 buildings; in five cold climate zones: 5A, 5B, 6A, 6B, 7. The building energy simulations demonstrated energy saving potentials, utility cost reductions and estimated payback periods.

Shen, Bo↗

Performance Analysis of High-Temperature Heat Pumps with Two-Phase Ejectors

A two-phase ejector recovers the energy in the refrigerant cycles’ throttling process, improving the coefficient of performance (COP) of high-temperature heat pumps (HTHPs). This study investigated the effects of the mixing pressure on the performance of two-phase ejectors and ejector-assisted HTHPs. A 1D theoretical model of a two-phase ejector was built to predict the internal fluid dynamics and evaluate ejector performance. A thermodynamic model of an ejector-assisted HTHP was built to evaluate the COP of HTHPs and the volumetric heating capacity of low-global warming potential refrigerants. The results demonstrate that an optimum mixing pressure in a two-phase ejector provides the best performance of a two-phase ejector and ejector-assisted HTHP. The optimum mixing pressure was slightly lower than the evaporation pressure. At this pressure, the two-phase flow in the ejector was subsonic. For ejector-assisted HTHPs using low–global warming potential refrigerants at a sink temperature of 120°C, temperature lift of 40°C, and subcooling of 10°C, a two-phase ejector has an average ejector efficiency of 0.334, and the COP and volumetric heating capacity were improved by 7.2% and 7.3%, respectively.

Wang, Pengtao↗

Adsorption cooling system using metal organic frameworks

A highly adsorptive structure includes: a substrate; and a metal-organic framework (MOF) comprising a plurality of metal atoms coordinated to a plurality of organic spacer molecules; wherein the MOF is coupled to at least one surface of the substrate, wherein the MOF is configured to adsorb and desorb a refrigerant under predetermined thermodynamic conditions. The refrigerant includes one or more materials selected from the group consisting of: acid halides, alcohols, aldehydes, amines, chlorofluorocarbons, esters, ethers, fluorocarbons, perfluorocarbons, halocarbons, halogenated aldehydes, halogenated amines, halogenated hydrocarbons, halomethanes, hydrocarbons, hydrochlorofluorocarbons, hydrofluoroethers, hydrofluoroolefins, inorganic gases, ketones, nitrocarbon compounds, noble gases, organochlorine compounds, organofluorine compounds, organophosphorous compounds, organosilicon compounds, oxide gases, refrigerant blends and thiols.

Baumann, Theodore F.↗

On the Corrosion Response of Novel Heat Exchangers Manufactured by Casting of Al-Ce-Mg Alloy

Developing low-cost and durable heat exchangers is critical for next-generation heating, ventilation, air conditioning, and refrigeration systems. The emerging requirement to minimize the total refrigerant charge inventory while ensuring a uniform distribution of refrigerant has led to the deployment of advanced manufacturing strategies. At the same time, corrosion is a longstanding issue for metal components, especially those used in heat exchanger (HX) applications. In this study, Al-Ce-Mg alloy-based HXs have been investigated. The corrosion resistance of HXs prototype manufactured by the casting process has been examined and the potential of a new manufacturing approach has been explored to meet the requirements of emerging needs.

Brechtl, Jamieson↗

Space Cooling: Recovery, Reuse, Recycling and Supply Chain Impacts

The global cooling sector has undergone tremendous growth in recent years, and cooling demand is projected to double or triple by 2050. Surging air conditioning demand will continue to be driven by increased populations, incomes and occurrences of extreme heat and humidity events. Cooling equipment growth has important pollution and material implications as they are made up of critical metals and precious raw materials - including ferrous metals, copper, aluminum and printed circuit boards composed of copper, silver, gold and palladium - that generate significant electronic waste at end-of-life. Air conditioning equipment also contains fluorinated gas (F-gas) refrigerants, which are potent gases that are thousands of times more heat-trapping than carbon dioxide (CO2). While recovery, reuse, and recycling strategies have been assessed for cold chain and refrigeration, there is currently limited analysis on how these strategies could be adopted for the global space cooling industry and potential supply chain implications. This paper aims to address this research gap by qualitatively evaluating product and material recovery, reuse and recycling frameworks from both demand and supply-side perspectives and with the support of cooling-specific case studies. It also focuses on quantitatively assessing potential energy, emissions and resource benefits of such strategies for space cooling equipment. This paper first analyzes how existing recovery, reuse and recycling frameworks can be applied to space cooling, with emphasis on the demand-side enablers (e.g., innovative business models, supporting policies and regulations) and changes in supply-side production network throughout the supply chain (e.g., design, production and distribution, end-of-life recovery) needed to overcome existing barriers. It will present case studies of innovative business models for space cooling technologies, including reuse and recycling, and how effective refrigerant reclamation and recovery programs have been operationalized. Lastly, the paper will highlight global modeling results of energy, emissions and material recovery from scenario analysis of selected strategies for air conditioners. The findings of this paper are intended to inform the development of product and material recovery, reuse and recycling strategies for a rapidly growing stock of space conditioning equipment by addressing existing organizational, economic and regulatory barriers and potential supply-chain bottlenecks.

Khanna, Nina↗

Artificial Intelligence Thermostat to Detect Faults

Residential air conditioners and heat pumps often experience faults due to inadequate maintenance, which can severely reduce efficiency or even cause system failure. Common issues include dirty or clogged air filters and refrigerant leaks. These problems degrade performance and increase energy use and operating costs. This study presents a smart thermostat with embedded artificial intelligence to detect such faults and alert homeowners when maintenance is needed. The thermostat uses low-cost measurements—including return-air temperature, relative humidity, supply-air temperature, outdoor-air temperature, and condenser subcooling—to identify abnormal operations. Because different faults produce distinct response patterns, tailored algorithms are developed to recognize characteristic fault signatures. The investigation is built on a detailed co-simulation platform that couples EnergyPlus with the DOE/ORNL Heat Pump Design Model (HPDM). EnergyPlus represents the building’s dynamic environment, while HPDM is a high-fidelity, hardware-based model that can simulate fault-free performance as well as a wide range of faults, including gradual degradation such as minor refrigerant leakage. This platform provides a virtual training and testing environment that helps distinguish fault-induced behavior from normal operation and supports development of robust diagnostic algorithms. Using this framework, a Dynamic Bayesian Network was developed to identify two common faults—gradual refrigerant charge loss and indoor airflow blockage—and the AI-embedded thermostat was verified through annual building simulations.

Shen, Bo [ORNL] (ORCID:0000000336600393)↗