Reactor physics benchmark of Westinghouse PWR core design suite for high burnup/high enrichment fuel - Part 2: 2D and 3D core simulations

Westinghouse has performed a comprehensive set of code-to-code benchmark comparisons to corroborate application of its state-of-the-art NEXUS-based code suite to high burnup and high enrichment (HB/HE) fueled PWR core design and reload analysis. The benchmark consisted of a progression in complexity from modeling single 2D pin cells, through 2D lattices and finally to whole core 2D and then 3D scenarios. The accompanying paper (Part 1) presented the results for a variety of pin cell and lattices representative of high energy cores and established the ability of the MPACT code to accurately match the predictions of the Monte-Carlo code SERPENT2 such that the former may be used as a surrogate reference code in spatially complex whole core modeling applications where using Monte-Carlo methods is somewhat impractical. This paper focuses on comparisons at the whole core level using a representative high power density 3-loop Westinghouse NSSS core operating for 24 month cycles employing high enriched fuel with use of combined burnable absorbers to hold down excess reactivity. The evolution of the core reactivity and power distribution characteristics throughout the cycle are calculated using the Westinghouse NEXUS-based code suite and compared to the results using MPACT. The results of this whole core benchmark confirm the conclusions that the Westinghouse code suite accurately models HB/HE fuel designs, with very good prediction of core reactivity and power distribution throughout the cycle. The industry can be confident that the NEXUS code system can be deployed to support PWR reload safety and operational analyses for cores featuring HB/HE fuel and 24-month cycle operation. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Efficient Region of Attraction Characterization for Control and Stabilization of Load Tap Changer Dynamics

In this article, we study the monitoring and control of long-term voltage stability considering load tap changer (LTC) dynamics. We show that under generic conditions, the LTC dynamics admit a unique stable equilibrium. For the stable equilibrium, we characterize an explicit inner approximation of its largest region of attraction (ROA). Compared to existing results, the computational complexity of the ROA characterization is drastically reduced. We propose a quadratically constrained linear program formulation for the ROA characterization problem. In addition, we formulate a second-order cone program for online voltage stability monitoring and control exploiting the proposed ROA characterization. Finally, we demonstrate the efficacy of the proposed formulations on the ROA characterization and stability monitoring and control using a standard IEEE test system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Effects-Based Monitoring of Geomagnetically-Induced Current Using a Convolutional Neural Network

Geomagnetically-induced current (GIC) due to space weather can flow in the power grid causing undesirable effects such as transformer overheating, misoperation of protection devices, and potential blackouts. It is therefore important to monitor GIC in the power grid to improve online situational awareness and decision-making of system operators during a geomagnetic disturbance. To avoid the costly installation of GIC monitors at transformers’ neutrals, it is desirable to find correlations between GIC and already-monitored parameters. Hence, this work proposed the use of a convolutional neural network (CNN) to compute GIC amplitudes from learned patterns in the time-series data of transformer even harmonic currents. Using an electromagnetic transient program, GIC injection simulations were performed for a modeled Dominion Energy Virginia (DEV) substation with two 504 MVA, 500/230 kV transformers. Data collected from these offline simulations were used to train the CNN to provide online GIC monitoring. Testing the CNN performance involved using real GIC measurements from published literature and from a physical GIC monitor in the DEV area. Finally, the results showed that the proposed method was able to provide GIC readings with a root mean squared error of 1.56 A/phase (equivalent to an average accuracy of 94%) for these real GIC waveforms.

42 ENGINEERING↗

Variable-Speed, Constant-Frequency Generation Of Power

Feedback of stator power and reactive volt-amperes determines rotor excitation. New method involves control circuit separating rotor excitation into generation of slip frequency and control of amplitude and phase. In control circuit, speed determines slip frequency, while stator power and reactive volt-amperes determine amplitude and phase of rotor current.

Brady, Frank J.↗

Deep reinforcement learning assisted co-optimization of Volt-VAR grid service in distribution networks

With the increasing penetration of distributed energy resources in distribution networks, Volt-VAR control and optimization (VVC/VVO) have become very important to ensure an acceptable quality of service to all customers. System operators can rely on slow-responding utility devices, including capacitor banks and on-load tap changing transformers, along with fast-responding battery and photovoltaic (PV) inverters for the VVC/VVO implementation. Because of variations in response time of these two classes of devices, and different control actions (discrete versus continuous), coordinated and optimal scheduling and operation have become of utmost importance. Here, this paper develops a look-ahead deep reinforcement learning (DRL)-based multi-objective VVO technique to improve the voltage profile of active distribution networks, decrease network and inverter power loss, and save the operational cost of the grid. It proposes a deep deterministic policy gradient (DDPG)-based approach to schedule the optimal reactive and/or active power set-points of fast-responding inverters, and a deep Q-network (DQN)-based DRL agent to schedule the discrete decisions variables of slow-responding assets. The reactive power output of PV and battery smart inverters are scheduled at 30-minute intervals and the capacitors’ commitment status is scheduled with several hour intervals. The proposed framework is validated on the modified IEEE 34-bus and 123-bus test cases with embedded PV and PV-plus-storage. To validate the efficacy of the proposed VVO, it is compared with several scenarios, including the base case without VVO, localized droop control of DERs, DDPG-only, and twin delayed DDPG (TD3) agent-based DRL techniques. The results justify the superior performance of the proposed method to improve the voltage profile, reduce network power loss, and minimize the look-ahead grid operational cost while minimizing the undesirable power losses in inverters as a result of power factor adjustments.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Testing of an Integrated Reactor Core Simulator and Power Conversion System with Simulated Reactivity Feedback

A Direct Drive Gas-Cooled (DDG) reactor core simulator has been coupled to a Brayton Power Conversion Unit (BPCU) for integrated system testing at NASA Glenn Research Center (GRC) in Cleveland, Ohio. This is a closed-cycle system that incorporates an electrically heated reactor core module, turboalternator, recuperator, and gas cooler. Nuclear fuel elements in the gas-cooled reactor design are replaced with electric resistance heaters to simulate the heat from nuclear fuel in the corresponding fast spectrum nuclear reactor. The thermodynamic transient behavior of the integrated system was the focus of this test series. In order to better mimic the integrated response of the nuclear-fueled system, a simulated reactivity feedback control loop was implemented. Core power was controlled by a point kinetics model in which the reactivity feedback was based on core temperature measurements; the neutron generation time and the temperature feedback coefficient are provided as model inputs. These dynamic system response tests demonstrate the overall capability of a non-nuclear test facility in assessing system integration issues and characterizing integrated system response times and response characteristics.

Bragg-Sitton, Shannon M.↗

Testing of an Integrated Reactor Core Simulator and Power Conversion System with Simulated Reactivity Feedback

A Direct Drive Gas-Cooled (DDG) reactor core simulator has been coupled to a Brayton Power Conversion Unit (BPCU) for integrated system testing at NASA Glenn Research Center (GRC) in Cleveland, OH. This is a closed-cycle system that incorporates an electrically heated reactor core module, turbo alternator, recuperator, and gas cooler. Nuclear fuel elements in the gas-cooled reactor design are replaced with electric resistance heaters to simulate the heat from nuclear fuel in the corresponding fast spectrum nuclear reactor. The thermodynamic transient behavior of the integrated system was the focus of this test series. In order to better mimic the integrated response of the nuclear-fueled system, a simulated reactivity feedback control loop was implemented. Core power was controlled by a point kinetics model in which the reactivity feedback was based on core temperature measurements; the neutron generation time and the temperature feedback coefficient are provided as model inputs. These dynamic system response tests demonstrate the overall capability of a non-nuclear test facility in assessing system integration issues and characterizing integrated system response times and response characteristics.

Bragg-Sitton, Shannon M.↗

An Innovative Energy Management System for Microgrids with Multiple Grid-Forming Inverters

As increasingly more grid-forming (GFM) inverter-based resources replace traditional fossil-fueled synchronous generators as the GFM sources in microgrids, the existing microgrid energy management systems (EMS) need to be updated to control and coordinate multiple GFM inverters that consider system control objectives under different microgrid connection states. For each state, we formulate an optimization problem and apply a real-time feedback-based control algorithm; altogether, the control algorithms seamlessly connect the states into a generic microgrid EMS that controls the nodal voltages and frequencies, becomes a virtual power plant (VPP) when connected to the main grid, and coordinates power sharing responsibility among GFM sources when islanded. We showcase the EMS on a real-world simulation of a microgrid under the different states to demonstrate its operational effectiveness.

energy management systems↗

Two-stage Stochastic Generalized Disjunctive Programming (GDP) Model for Proactive Planning and Reactive Operations of Resilient Power Systems under Disruptions

In this work, we propose a Generalized Disjunctive Programming (GDP) model that optimizes both long-term capacity planning (such as the number and size of dispatchable/renewable generators, batteries, and transmission lines) and hourly operation (such as on/off schedules of dispatchable generators, power output from each generator, and power flow) to maximize power system reliability while minimizing total cost and CO2 emissions.

Cho, Seolhee↗

Electrical Validation Testing for ORPC MHK Generator, Modification 6: ORPC SBV for MHK Generator System (CRADA Final Report)

For the U.S. Department of Energy’s (DOE) 2016 Small Business Voucher for Marine and Hydrokinetic (MHK) System, Second Round 2016, ORPC intends to work with the National Renewable Energy Laboratory (NREL) to perform dynamometer testing of the MHK generator systems and its associated controls and inverters. ORPC will provide the generator, variable frequency drives (VFD), controls, and inverter for this testing. NREL will utilize the NREL Energy Systems Integration Facility (ESIF) and dynamometer facilities at the National Wind Technology Center (NWTC) for this work. Modification 6: Additionally, NREL will conduct a feasibility study for implementing passive DC rectification at the turbine.

17 WIND ENERGY↗

Core Design of the Holos-Quad Microreactor

The Holos-Quad micro-reactor concept, developed by HolosGen LLC, is equipped with a 22 MWt (Mega-Watt thermal) core and an integral power conversion system converting the core thermal energy into approximately 10 MWe (Mega-Watt electric). This design can be configured to support a wide range of applications. It is a very innovative high-temperature gas-cooled reactor concept using TRI-structural ISOtropic particle fuel (TRISO) distributed in graphite hexagonal blocks, cooled with helium in a direct Brayton cycle independently executed by four Subcritical Power Modules (SPMs) fitted into a hardened 40-foot container whose dimensions are in compliance with ISO shipping containers requirements. In FY2019 HolosGen LLC was awarded by the Department of Energy Advanced Research Project Agency-Energy (DOE ARPA-E) under the MEITNER funding program. As part of the MEITNER award, the Argonne National Laboratory (ANL) contributed expertise through two specialized teams: The “Design Team” and the “Resource Team”. The Design Team was dedicated to validate feasibility of the Holos-Quad core and to optimize its core design through neutronics analyses. The Resource Team was dedicated to feasibility verification via high-fidelity codes of Holos-Quad thermal-hydraulic, heat transfer, shielding, and structural aspects. This report summarizes the activities conducted by ANL Design Team. A rigorous design approach based on multi-criteria optimization and code-to-code comparison involving stochastic and high-fidelity deterministic solutions was developed and employed at several evolutionary stages of the Holos-Quad design. Several generations of the Holos-Quad core were designed within this project before converging to the current full-scale Gen 2+ design that is detailed in this report. Figure EA-1 illustrates a cross-sectional view of Gen 2+ Holos-Quad core configuration, and Figure EA-2 provides a simplified perspective view of 1-of-4 SPMs. The Holos-Quad uses four thermal-hydraulically independent SPMs locked into stationary positions during power operation, surrounded by BeO reflector and structural component fully comprised within the dimensional constraints represented by traditional ISO containers. One of the benefits of this approach is to enable transportation of each SPM promptly after irradiation in shielded containers. The core is designed to operate for approximately 8 full-power years while the reactivity controls and power conversion system enable load-following operations. The reactivity controls are represented by independent, diversified, and redundant reactivity control systems based on control drums and redundant sets of shutdown rods. The high-fidelity simulation tools were used to assess detailed power and flux distributions of the three-dimensional full-core or quarter-core of the Gen 2+ configuration. Single-physics and multi-physics simulations of the neutronics code PROTEUS and the thermal-hydraulic code System Analysis Module (SAM) were performed to analyze the Holos design configurations with detailed high-fidelity solutions. The design work performed confirmed feasibility of the Holos-Quad concept, provided realistic design description for detailed design of the operational system, and identified several core design improvements to be further considered for future reactor development activities.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

AC Power Flow Based DLMP Calculation and Decomposition Method to Smooth Power Fluctuation of Distributed Renewable Energy Sources

As the penetration of renewable energy sources increases, the growing renewable power variability brings ramping issues to power systems. Meanwhile, the development of distributed energy resources (DERs) makes the distribution systems to provide both energy and ancillary services. To incentivise individual resources and customers to alleviate ramping issues on the demand side, a two-stage distribution locational marginal price (DLMP) calculation and decomposition method is developed to formulate the marginal power ramping price for DERs. In the first stage of the proposed method, a distribution system operator market scheduling model based on AC optimal power flow is designed to estimate the optimal operating point of the distribution system. Subsequently, the voltage and power flow constraints are linearised in stage two to calculate DLMP. Finally, based on the Lagrange function and sensitivity factors, DLMP is decomposed to the marginal costs for active/reactive power, voltage management, power loss and power variability. Case studies demonstrate that the proposed model can effectively smooth the power fluctuation and reduce the ramping flexibility requirements of distribution systems.

AC optimal power flow↗

Uncertainty analysis for VERA problem 2 using the cell-code Condor v2.8.05

Condor is a cell-level neutronic calculation code that applies multi-group collision probabilities with heterogeneous response coupling method within generic geometry configurations. Under the Condor's code continuous development, the incorporation of up-to-date methodologies and state-of-the-art practices in reactor analysis represents a driving force. In this work, the capabilities of Condor v2.8.05 to develop an uncertainty analysis for realistic PWR-kind fuel assemblies are studied. The Total Monte Carlo approach is applied to quantify the impact of fabrication tolerances in the code's results for reactivity and power distributions, by means of randomly sampled input values using the VERA problem 2 as basis. The VERA problem 2 proposes a series of Westinghouse 2D 17 x 17-type fuel lattices, to be calculated reflected at beginning-of-life without Xe. The configurations correspond to a modern PWR. Selected neutronic parameters from Condor runs are thus analyzed in terms of the observed spread as well as the obtained distributions for the randomly perturbed cases, showing the capability of the code to handle the required input data, as well as its ability to provide valuable insights regarding uncertainty quantification.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗