Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ray trace”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Laser heating system at the Extreme Conditions Beamline, P02.2, $\mathrm{PETRA III}$

A laser heating system for samples confined in diamond anvil cells paired with in situ X-ray diffraction measurements at the Extreme Conditions Beamline of PETRA III is presented. The system features two independent laser configurations (on-axis and off-axis of the X-ray path) allowing for a broad range of experiments using different designs of diamond anvil cells. The power of the continuous laser source can be modulated for use in various pulsed laser heating or flash heating applications. An example of such an application is illustrated here on the melting curve of iron at megabar pressures. The optical path of the spectroradiometry measurements is simulated with ray-tracing methods in order to assess the level of present aberrations in the system and the results are compared with other systems, that are using simpler lens optics. Based on the ray-tracing the choice of the first achromatic lens and other aspects for accurate temperature measurements are evaluated.

47 OTHER INSTRUMENTATION↗

Bent Laue crystal anatomy: new insights into focusing and energy-dispersion properties

X-ray Laue-type monochromators are common and essential optical components at many high-power X-ray facilities, e.g. synchrotron facilities. The X-ray optics of bent Laue crystals is a well developed area. An incident X-ray beam penetrating a bent Laue crystal will result in a diffracted beam with different angles and energies. There is a need for a way of organizing the rays that allows one to sort out the energy and spatial properties of the diffracted beam. The present work introduces a new approach for describing the general behaviour of bent Laue crystals from a ray-tracing point of view. This quasi-monochromatic beam approach provides an intuitive view of bent-crystal diffraction and leads to deeper understanding. It explains the energy and spatial properties of common and special cases of bent Laue optics, predicts phenomena that can improve energy-dispersion-related X-ray imaging techniques and provides a theoretical framework that makes ray-tracing simulation easier to realize.

36 MATERIALS SCIENCE↗

Dislocation contrast on X-ray topographs under weak diffraction conditions

The contrast of dislocations in 4H-SiC crystals shows distinctive features on grazing-incidence X-ray topographs for diffraction at different positions on the operative rocking curve. Ray-tracing simulations have previously been successfully applied to describe the dislocation contrast at the peak of a rocking curve.The present work shows that the dislocation images observed under weak diffraction conditions can also be simulated using the ray-tracing method. Furthermore, these simulations indicate that the contrast of the dislocations is dominated by orientation contrast. Analysis of the effective misorientation reveals that the dislocation contrast in weak-beam topography is more sensitive to the local lattice distortion, consequently enabling information to be obtained on the dislocation sense which cannot be obtained from the peak.

36 MATERIALS SCIENCE↗

A split-beam probe-pump-probe scheme for femtosecond time resolved protein X-ray crystallography

In order to exploit the femtosecond pulse duration of X-ray Free-Electron Lasers (XFEL) operating in the hard X-ray regime for ultrafast time-resolved protein crystallography experiments, critical parameters that determine the crystallographic signal-to-noise (I/σI) must be addressed. For single-crystal studies under low absorbed dose conditions, it has been shown that the intrinsic pulse intensity stability as well as mode structure and jitter of this structure, significantly affect the crystallographic signal-to-noise. Here, geometrical parameters are theoretically explored for a three-beam scheme: X-ray probe, optical pump, X-ray probe (or “probe-pump-probe”) which will allow experimental determination of the photo-induced structure factor amplitude differences, ΔF, in a ratiometric manner, thereby internally referencing the intensity noise of the XFEL source. In addition to a non-collinear split-beam geometry which separates un-pumped and pumped diffraction patterns on an area detector, applying an additional convergence angle to both beams by focusing leads to integration over mosaic blocks in the case of well-ordered stationary protein crystals. Ray-tracing X-ray diffraction simulations are performed for an example using photoactive yellow protein crystals in order to explore the geometrical design parameters which would be needed. The specifications for an X-ray split and delay instrument that implements both an offset angle and focused beams are discussed, for implementation of a probe-pump-probe scheme at the European XFEL. We discuss possible extension of single crystal studies to serial femtosecond crystallography, particularly in view of the expected X-ray damage and ablation due to the first probe pulse.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Design of the soft x-ray tomography beamline at Taiwan photon source

The optical design of the varied-line-spacing plane-grating monochromator for transmission full-field imaging of frozen-hydrated biological samples at NSRRC is presented. This monochromator consists of a plane mirror and three interchangeable gratings with groove densities 600, 1200 and 2400 l/mm to cover the energy range 260 – 2600 eV. The groove parameters of the varied-line-spacing plane gratings are designed to minimize the effect of coma and spherical aberration to maintain the exit slit in focus for any value of incident angle. All parameters of optical components at the beamline are verified with a ray-tracing method. In the beamline design, the calculated results from the ray-tracing codes and the expected performances are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development and Experimental Optimization of High-Temperature Modeling Tools and Methods for Concentrated Solar Power Particle - Systems

A novel, open-source radiative modeling toolset was developed to extend the functionality of particle-based modeling software (e.g. discrete element method (DEM)) to environmental conditions relevant to concentrated solar power applications. This toolset was optimized for deployment on desktop workstations instead of high-performance computing systems, to render such tools more accessible to the research community. Both particle-based modeling and radiative exchange modeling are computationally expensive and often require specialized programming expertise, making these methods cumbersome to use. Recent developments in DEM software by DCS Computing have greatly reduced these challenges, providing a graphical-user-interface based platform and modeling optimization for desktop workstations, HPCs, and cloud computing. The University of Dayton leveraged the experience of DCS Computing in developing a user-friendly, open-source radiative heat transfer expansion for DEM modeling. The University of Dayton DEM+ radiative modeling toolset was developed using a combination of fundamental experimental measurements, modeling, and simplified flow experiments over a range of temperatures and flow conditions. The toolset provides researchers with access to multiple radiative models including an accelerated Monte-Carlo Ray Tracing (application agnostic, highly computationally expensive), an expanded database of distance-based approximations (application limited, computationally light), and a weighted blending of the two methods capable of achieving over 90% reduction in computation time with equivalent accuracy compared to Monte-Carlo Ray Tracing. Through a graphical user interface, users can customize the radiative models to match their desired accuracy and available computational resources, improving access to particle based modeling for the research community. Ceramic sintered bauxite proppants were used in modeling and experimentally as a baseline. Both the radiative heat transfer and flow properties for particulate systems were investigated at elevated temperatures up to 800 °C. The major accomplishments for this work include a verified, open-source radiative modeling toolset to be distributed amongst the research community and the fabrication of three small-scale test facilities to investigate particle behavior and tune DEM flow properties for operation up to 800 °C. The findings have been shared with the research community via conference modeling workshops, deployment of the tools in DCS Computing Aspherix®, and open-source access to the developed radiative modeling tool. The development of next-generation CSP facilities and thermal energy storage systems based on ceramic particles requires providing access to computationally efficient and accurate modeling tools. Particles will experience a wide range of environments (20-800 °C) and handling conditions (dilute curtains or dense packing), requiring specially designed and optimized equipment. Optimizing solid particle physics models and establishing best-practices for particle modeling in CSP environments will assist researchers with designing optimized equipment, accelerating the deployment of more economically-competitive CSP facilities.

14 SOLAR ENERGY↗

Design study of a laser-cooled infrared sensor

The performance of a solid-state optical refrigerator is the result of a complex interplay of numerous optical and thermal parameters. We present a first preliminary study of an optical cryocooler using ray-tracing techniques. A numerical optimization identified a non-resonant cavity with astigmatism. This geometry offered more efficient pump absorption by the YLF:10%Yb laser-cooling crystal compared to non-resonant cavities without astigmatism that have been pursued experimentally so far. Ray tracing simulations indicate that ~80% of the incident pump light can absorbed for temperatures down to ~100 K. Calculations of heat loads, cooling power, and net payload heat lift are presented. They show that it is possible to cool a payload to a range of 90–100 K while producing a net payload heat lift of 80 mW and 300 mW when pumping a YLF:10%Yb crystal with 20 W and 50 W at 1020 nm, respectively. This performance is suited to cool HgCdTe infrared detectors that are used for sensing in the 8–12 μm atmospheric window. While the detector noise would be ~6× greater at 100 K than at 77 K, the laser refrigerator would introduce no vibrations and thus eliminate sources of microphonic noise that are limiting the performance of current systems.

47 OTHER INSTRUMENTATION↗

Fast physics-based launcher optimization for electron cyclotron current drive

With the increased urgency to design fusion pilot plants, fast optimization of electron cyclotron current drive (ECCD) launchers is paramount. Traditionally, this is done by coarsely sampling the 4D parameter space of possible launch conditions consisting of (1) the launch location (constrained to lie along the reactor vessel), (2) the launch frequency, (3) the toroidal launch angle, and (4) the poloidal launch angle. For each initial condition, a ray-tracing simulation is performed to evaluate the ECCD efficiency. Unfortunately, this approach often requires a large number of simulations (sometimes millions in extreme cases) to build up a dataset that adequately covers the plasma volume, which must then be repeated every time the design point changes. Here we adopt a different approach. Rather than launching rays from the plasma periphery and hoping for the best, we instead directly reconstruct the optimal ray for driving current at a given flux surface using a reduced physics model coupled with a commercial ray-tracing code. Repeating this throughout the plasma volume requires only hundreds of simulations, constituting a significant speedup. The new method is validated on two separate example tokamak profiles, and is shown to reliably drive localized current at the specified flux surface with the same optimal efficiency as obtained from the traditional approach.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Analyzing acoustic emission data to identify cracking modes in cement paste using an artificial neural network

This research is focused on the identification of cracking mechanisms for cement paste using acoustic emission data, recorded from compression and notched four-point bending tests. A procedure is developed for analyzing the data by employing an agglomerative hierarchical clustering method, an artificial neural network, and a ray-tracing source location algorithm. An agglomerative hierarchical clustering method is utilized to cluster the AE data from a compression test using frequency-dependent features. A neural network is trained using the compression test data and applied to the AE data emitted during the four-point bending test. The clustered data from the four-point bending test is localized using a ray-tracing algorithm. Based on the occurrence and locations of the clustered events and signal feature analyses, potential cracking mechanisms are identified and assigned.

36 MATERIALS SCIENCE↗

Absolute throughput calibration of multiple spherical crystals for the Orion High-REsolution X-ray spectrometer (OHREX)

We present absolute throughput analysis of several crystals for the Orion High-REsolution X-ray (OHREX) imaging crystal spectrometer using ray tracing and experimental measurements. The OHREX spectrometer is a high-resolution x-ray spectrometer designed to measure spectral line shapes at the Orion laser facility. The spectrometer is fielded with up to two spherical crystals simultaneously covering two independent spectral ranges. Each crystal has a nominal radius of curvature of R = 67.2 cm and is fielded at a nominal Bragg angle of 51.3°. To cover different bands of interest, several different crystals are available, including Ge (111), KAP, and several cuts of quartz, whose resolving power λ/Δλ exceeds 10 000. The calibrated response of the available crystals has previously been reported from measurements at the EBIT-I electron beam ion trap at Lawrence Livermore National Laboratory. Here, we model the absolute throughput of each crystal using ray tracing and verify the results using experimental data for the quartz $(10\bar{1}1)$ crystal.

47 OTHER INSTRUMENTATION↗

Gamma-ray bursts trace UV metrics of star formation over 3 < z < 5

We present the first uniform treatment of long duration gamma-ray burst (GRB) host galaxy detections and upper limits over the redshift range 3 −15.6 mag, and with extrapolations of the assumed Schechter-type LF well beyond this range. We review proposed astrophysical and observational biases for our sample, and find that they are for the most part minimal. We therefore conclude, as the simplest interpretation of our results, that GRBs successfully trace UV metrics of cosmic SF over the range 3<z<5. Our findings suggest that GRBs provide an accurate picture of star formation processes from z≈3 out to the highest redshifts.

79 ASTRONOMY AND ASTROPHYSICS↗

EBW Physics of ECE in NSTX

Topics covered include: ray tracing and Fokker-Planck coupling; relativistic and electromagnetic effects in EBW damping (ray-tracing); O-X-EBW mode conversion efficiency limit due to finite beam divergence; general prospects for electron Bernstein wave heating and current drive in spherical tokamaks; sensitivity of EBW H&CD; collisional effects on EBW coupling; and EBW propagation in a high-temperature plasma.

14 SOLAR ENERGY↗

Absolute throughput calibration of multiple spherical crystals for the Orion High-REsolution X-ray spectrometer (OHREX)

We present absolute throughput analysis of several crystals for the Orion High-REsolution X-ray (OHREX) imaging crystal spectrometer using ray tracing and experimental measurements. The OHREX spectrometer is a high-resolution x-ray spectrometer designed to measure spectral line shapes at the Orion laser facility. The spectrometer is fielded with up to two spherical crystals simultaneously covering two independent spectral ranges. Each crystal has a nominal radius of curvature of R = 67.2 cm and is fielded at a nominal Bragg angle of 51.3°. To cover different bands of interest, several different crystals are available, including Ge (111), KAP, and several cuts of quartz, whose resolving power λ/Δλ exceeds 10 000. The calibrated response of the available crystals has previously been reported from measurements at the EBIT-I electron beam ion trap at Lawrence Livermore National Laboratory. Here, we model the absolute throughput of each crystal using ray tracing and verify the results using experimental data for the quartz (10¯11) crystal.

M. J. MacDonald↗

Investigating the origin of the far-field reflection interference fringe (RIF) of microdroplets

We show that the reflection interference fringe (RIF) is formed on a screen far away from the microdroplets placed on a prism-based substrate, which have low contact angles and thin droplet heights, caused by the dual convex–concave profile of the droplet, not a pure convex profile. The geometric formulation shows that the interference fringes are caused by the optical path difference when the reflected rays from the upper convex profile at the droplet–air interface interfere with reflection from the lower concave profile at oblique angles lower than the critical angle. Analytic solutions are obtained for the droplet height and the contact angle out of the fringe number and the fringe radius in RIF from the geometric formulation. Furthermore, the ray tracing simulation is conducted using the custom-designed code. The geometric formulation and the ray tracing show excellent agreement with the experimental observation in the relation between the droplet height and the fringe number and the relation between the contact angle and the fringe radius. This study is remarkable as the droplet's dual profile cannot be easily observed with the existing techniques. However, the RIF technique can effectively verify the existence of a dual profile of the microdroplets in a simple setup. In this work, the RIF technique is successfully developed as a new optical diagnostic technique to determine the microdroplet features, such as the dual profile, the height, the contact angle, the inflection point, and the precursor film thickness, by simply measuring the RIF patterns on the far-field screen.

42 ENGINEERING↗

Geometric effects of global lateral heterogeneity on long-period surface wave propagation

The present investigation has the objective to document examples of anomalous long-period surface wave amplitude behavior and to provide a preliminary appraisal of the effects of global lateral heterogeneity on surface wave propagation from a ray theory perspective. Attention is given to remarkable long-period surface wave anomalies described in literature, an equidistance azimuthal plot centered on the Iranian source region, Rayleigh wave and Love wave spectra for the 256-s period arrivals for the Tabas earthquake, constrained moment tensor and fault model inversion solutions ofr Iranian earthquakes, aspects of surface wave ray tracing, and a table of Rayleigh wave amplitude anomalies for Iranian earthquakes. Surface wave ray-tracing calculations for models of global phase velocity variations proposed by Nakanishi and Anderson (1984) are found to show that large-amplitude anomalies will be observed for Love and Rayleigh waves with periods of 100-250 s.

Lay, T.↗

Cold plasma diagnostics using satellite measurements of VLF signals from ground transmitters

A diagnostic technique to obtain the cold-plasma density profile in the magnetosphere is introduced. This method uses satellite measurements of group delay and pulse duration of VLF signals from ground transmitters in conjunction with a detailed ray-tracing analysis. An iterative method is involved which starts with an approximate density profile, computes the ray paths for that profile, and then compares the properties of the rays that reach the satellite location with the actual satellite measurements. The density profile is then modified to account for any discrepancies between the two results. The same process is repeated with the new profile until one has reasonable agreement between the data and ray-tracing results. This method is applied to the case of an Imp 6 pass, where strong signals from the Siple VLF transmitter were observed for over 25 min. Good agreement is found between the results of the proposed technique and the well-known ground whistler techniques of cold-plasma diagnostics. The results also serve to illustrate the wide diversity of propagation paths from ground transmitters to high-altitude satellites during VLF wave-injection experiments.

Inan, U. S.↗

A new method for visualizing data on a sphere

A method for visualizing data on a globe or unit sphere is described. Information that is distributed over a sphere - global oceanographic or geographic measurements, all-sky astronomy observations, or any quantities that are best represented in spherical coordinates - can benefit from this technique. Retaining a better sense of the geometry and information content of the data, 3D graphics can provide an unobstructed view of the entire sphere, without undue deformation of its surface area. A 'parameterized ray trace' produces look-up tables (LUTs) that can be used for all visualizations. The ray-trace result shows one or more spheres with the data as a texture map and three reflecting rectangles that 'mirror' the far sides of the sphere(s) into view. The LUTs need only be created once. No special purpose hardware is required beyond a PC or workstation that supports color. Examples from astronomical and geophysical datasets, which are commonly displayed with an area deforming (2D) projection, are presented.

Hon, David↗

Elevating SolTrace's Capabilities for the Next Generation of Concentrating Solar Analysis

SolTrace is an open-source Monte Carlo ray tracing software developed at NREL. SolTrace can characterize concentrating solar thermal (CST) collector optical performance and is CST technology agnostic. Shown in Fig. 1, SolTrace is a foundational tool in NREL's CST system and component modeling suite. SolTrace's generic surface elements can flexibly model novel collector and receiver designs to predict spatial and temporal flux distributions - critical to understand for CST component design, performance prediction, and system integration. Since its initial development, SolTrace has over 1,650 references on Google Scholar, over 9,800 downloads since 2017, and has served the CST research and development community as a benchmark of 3rd party verification. SolTrace provides users with many options for defining surface shape and boundaries. However, SolTrace provides limited documentation which can result in a steep learning curve for new users. Additionally, SolTrace lacks the computational performance required to evaluate optical performance of a CST system over the course of a year and/or iteratively over design parameters in a timely manner. To address this, we are working towards a new release of SolTrace that enables increased computational throughput by implementing ray tracing acceleration structures and enabling GPU parallelization. Additionally, we are working to improve SolTrace's usability, accessibility, and maintainability by (1) automating solar position time-dependent simulation processes, (2) creating general CST collector templates of grouped elements, (3) updating the user interface to better visualize model inputs and outputs, and (4) creating a user support network through forums, "how to" videos, and documentation.

14 SOLAR ENERGY↗