Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “raman”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Effect of Particle Size on Raman Signal Strength of Silicate Minerals

Understanding the effects of particle size is necessary for quantifying minerals in mixtures using Raman spectroscopy. Raman signal intensity is evaluated using six common silicate minerals (two olivines, two pyroxenes, and two feldspars) at 10 particle size ranges. For olivines and feldspars, the highest peak intensities are observed in samples with 38–63 and 63–106 μm particle sizes. There is no such consistent trend for the pyroxene samples, although the overall low signal strength complicates those measurements. In conclusion, Raman spectra of samples with varying particle sizes appear to be influenced by two competing effects: scattering from particle boundaries and effective sampling volume.

58 GEOSCIENCES↗

Development of chemometric models to classify solid-state U materials by micro-Raman spectroscopy

Discerning uranium (U) particles found in environmental sampling is of interest for monitoring the peaceful use of nuclear material. In this study, a soft independent modeling of class analogy (SIMCA) library was successfully developed for the classification of a four-class system consisting of α-U 3 O 8 , UO 2 , UO 2 (NO 3 ) 2 ·6H 2 O (UNH), and UO 2 O 2 ·4H 2 O (studtite) by Raman spectroscopy in the presence of matrix particulates and additional outliers. Spectral variability between numerous particles of each type revealed appreciable differences as a function of particle size with respect to hydration state and potential oxide phase within each class. Interclass variability was accounted for using both unsupervised and supervised chemometric models. The supervised SIMCA model displayed reasonable sensitivity for each U class and a high degree of specificity by returning whether a spectrum belonged to one class or not. This work demonstrates how Raman spectral features and chemometrics can be used to distinguish U materials from one another and from matrix materials such as flint clay. Combining the outlined chemometric approach with Raman mapping sequences could provide a rapid, nondestructive technique to characterize the chemical composition of a diverse collection of U compounds amid background samples for environmental sampling, nuclear forensics, and industrial applications.

Actinide↗

On-Line Monitoring of Gas-Phase Molecular Iodine Using Raman and Fluorescence Spectroscopy Paired with Chemometric Analysis

Molten salt reactors (MSRs) have the potential to safely support green energy goals. However, licensing and deployment of these systems will be aided through development of new technology. This includes on-line monitoring tools for real-time compositional analysis. Of particular interest is quantifying iodine within reactor off-gas streams to support design and operational control of reactor off-gas treatment systems. Here we discuss the development of advanced Raman spectroscopy systems for the on-line analysis of I 2(g) within the gas phase. Signal response is explored with two Raman instruments utilizing a 532 nm and a 671 nm excitation source, as a function of I 2(g) pressure and temperature. Furthermore, the applicability of chemometric modeling for advanced analysis of data is explored. Raman spectroscopy paired with chemometric analysis is demonstrated to be a powerful route to analyzing I 2(g) composition within the gas phase, which lays the foundation for applications within molten salt reactor off-gas analysis and other significant chemical processes producing iodine species.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Resonance Raman Study of Shell Morphology in InP/ZnSe/ZnS Core/Shell/Shell Nanocrystals

Resonance Raman spectra and absolute cross sections of InP/ZnSe/ZnS core/shell/shell nanocrystals have been obtained at excitation wavelengths of 501.7, 457.9, and 410 nm. Eight different structures having nearly the same lowest excitonic absorption wavelength but significantly different stoichiometries are compared. The Raman spectra show phonon features attributable to both the InP core and the ZnSe shell. The largest differences among the structures are seen in the ZnSe phonon region by using excitation at 457.9 nm, on the low-energy edge of the absorption features having significant contributions from the ZnSe shell. Here, structures that are nearly stoichiometric (In:P ratio ≈1.0) show a sharp, strongly polarized peak near the bulk ZnSe phonon frequency (~250 cm –1 ) and a weak lower-frequency shoulder with a higher depolarization ratio. Structures having excess indium show a stronger low-frequency shoulder near 225 cm –1 and lower integrated Raman intensities throughout the ZnSe phonon region. These changes are attributed to the presence of indium atoms in the ZnSe shell. Furthermore, these results support a previous assignment of a slow rise component in the time-resolved photoluminescence spectra of nonstoichiometric structures to transient trapping of holes at indium defects in the shell.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Tip-Enhanced Multipolar Raman Scattering

We record nanoscale chemical images of thiobenzonitrile (TBN)-functionalized plasmonic gold nanocubes via tip-enhanced Raman spectroscopy (TERS). The spatially averaged optical response is dominated by conventional (dipolar) TERS scattering from TBN but also contains weaker spectral signatures in the 1225-1500 cm-1 region. The weak optical signatures dominate some of the recorded single pixel spectra. We can uniquely assign these Raman forbidden transitions to multipolar Raman scattering, which implicates spatially varying enhanced electric field gradients at plasmonic tip-sample nanojunctions. Specifically, we can assign observations of tip-enhanced electric dipole-magnetic dipole as well as electric dipole-electric quadrupole driven transitions. These signals need to be understood and accounted for in the interpretation of TERS spectral images, particularly in on-going quests aimed at chemical reaction mapping via TERS.

Wang, Chih-Feng↗

The Local Electronic Structure of Supercritical CO 2 from X-ray Raman Spectroscopy and Atomistic-Scale Modeling

Supercritical CO 2 is encountered in several technical and natural systems related to biology, geophysics, and engineering. While the structure of gaseous CO 2 has been studied extensively, the properties of supercritical CO 2 , particularly close to the critical point, are not well-known. Here, in this work, we combine X-ray Raman spectroscopy, molecular dynamics simulations, and first-principles density functional theory (DFT) calculations to characterize the local electronic structure of supercritical CO 2 at conditions around the critical point. The X-ray Raman oxygen K-edge spectra manifest systematic trends associated with the phase change of CO 2 and the intermolecular distance. Extensive first-principles DFT calculations rationalize these observations on the basis of the 4sσ Rydberg state hybridization. X-ray Raman spectroscopy is found to be a sensitive tool for characterizing electronic properties of CO 2 under challenging experimental conditions and is demonstrated to be a unique probe for studying the electronic structure of supercritical fluids.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Distinct magneto-Raman signatures of spin-flip phase transitions in CrI 3

The discovery of 2-dimensional (2D) materials, such as CrI 3 , that retain magnetic ordering at monolayer thickness has resulted in a surge of both pure and applied research in 2D magnetism. Here, we report a magneto-Raman spectroscopy study on multilayered CrI 3 , focusing on two additional features in the spectra that appear below the magnetic ordering temperature and were previously assigned to high frequency magnons. Instead, we conclude these modes are actually zone-folded phonons. We observe a striking evolution of the Raman spectra with increasing magnetic field applied perpendicular to the atomic layers in which clear, sudden changes in intensities of the modes are attributed to the interlayer ordering changing from antiferromagnetic to ferromagnetic at a critical magnetic field. Our work highlights the sensitivity of the Raman modes to weak interlayer spin ordering in CrI 3 .

47 OTHER INSTRUMENTATION↗

Ramification of complex magnetism in Nd 2 Ir 2 O 7 observed by Raman scattering spectroscopy

Using Raman scattering spectroscopy, we uncover a complex magnetic behavior of Nd2Ir2O7, which stands out among magnetic pyrochlores by the lowest temperature of the all-in-all-out (AIAO) Ir moments ordering (${T}_{{\rm{Ir}}}^{{\rm{N}}} = 33$ K) and the highest temperature at which AIAO order of rare-earth Nd ions is detected (${T}_{{\rm{Nd}}}^{{\rm{* }}}$ = 15 K). Detected magnetic Raman scattering and calculations of expected response allow us to demonstrate that the ordering of Ir magnetic moments is accompanied by an appearance of one-magnon Raman modes at 26.3 and 29.6 meV compatible with the AIAO order and allowing to estimate the energies of Ir-Ir interactions. An additional two-magnon excitation of the AIAO Nd order at around 33 meV appears in the spectra below the ordering temperature of Nd moments ${T}_{{\rm{Nd}}}^{{\rm{* }}}$ = 15 K. In the temperature range between 15 K and 33 K we observe a broad mode, which demonstrates strong temperature dependence and shifts on cooling below 20 K from 14 meV to higher frequencies, and disappears at 5 K, when two-magnon excitation of Nd moments becomes prominent. We suggest an interpretation of this excitation in terms of continuum arising from collective fluctuations of Nd moments above the transition. This complex behavior emerges from the interplay of strong spin-orbit coupling, electronic correlations, and geometric frustration on two magnetic pyrochlore sublattices of Nd and Ir ions.

magnetic properties and materials↗

Raman and X-ray diffraction study of pressure-induced phase transition in synthetic Mg 2 TiO 4

Synthetic Mg 2 TiO 4 qandilite was investigated to 50 and 40.4 GPa at room temperature using Raman spectroscopy and X-ray diffraction, respectively. The Raman measurements showed that cubic Mg 2 TiO 4 spinel transforms to a high pressure tetragonal (I4 1 /amd, No.141) phase at 14.7 GPa. Owing to sluggish kinetics at room temperature, the spinel phase coexists with the tetragonal phase between 14.7 and 24.3 GPa. In the X-ray diffraction experiment, transformation of the cubic Mg 2 TiO 4 to the tetragonal structure was complete by 29.2 GPa, ~5 GPa higher than the transition pressure obtained by Raman measurements, owing to slow kinetics. The obtained isothermal bulk modulus of Mg 2 TiO 4 spinel is K T0 = 148(3) GPa when K T0 ’ = 6.6, or K T0 = 166(1) GPa when K T0 ’ is fixed at 4. The isothermal bulk modulus of the high-pressure tetragonal phase is calculated to be 209(2) GPa and V 0 = 270(2) Å 3 when K T0 ’ is fixed at 4, and the volume reduction on change from cubic to tetragonal phase is about 9%. The calculated thermal Grüneisen parameters (γ th ) of cubic and tetragonal Mg 2 TiO 4 phases are 1.01 and 0.63. Based on the radii ratio of spinel cations, a simple model is proposed to predict post-spinel structures.

36 MATERIALS SCIENCE↗

Radiation-induced alteration of apatite on the surface of Mars: first in situ observations with SuperCam Raman onboard Perseverance

Abstract Planetary exploration relies considerably on mineral characterization to advance our understanding of the solar system, the planets and their evolution. Thus, we must understand past and present processes that can alter materials exposed on the surface, affecting space mission data. Here, we analyze the first dataset monitoring the evolution of a known mineral target in situ on the Martian surface, brought there as a SuperCam calibration target onboard the Perseverance rover. We used Raman spectroscopy to monitor the crystalline state of a synthetic apatite sample over the first 950 Martian days (sols) of the Mars2020 mission. We note significant variations in the Raman spectra acquired on this target, specifically a decrease in the relative contribution of the Raman signal to the total signal. These observations are consistent with the results of a UV-irradiation test performed in the laboratory under conditions mimicking ambient Martian conditions. We conclude that the observed evolution reflects an alteration of the material, specifically the creation of electronic defects, due to its exposure to the Martian environment and, in particular, UV irradiation. This ongoing process of alteration of the Martian surface needs to be taken into account for mineralogical space mission data analysis.

Science & Technology - Other Topics↗

Correlative SIP-FISH-Raman-SEM-NanoSIMS links identity, morphology, biochemistry, and physiology of environmental microbes

Microscopic and spectroscopic techniques are commonly applied to study microbial cells but are typically used on separate samples, resulting in population-level datasets that are integrated across different cells with little spatial resolution. To address this shortcoming, we developed a workflow that correlates several microscopic and spectroscopic techniques to generate an in depth analysis of individual cells. By combining stable isotope probing (SIP), fluorescence in situ hybridization (FISH), scanning electron microscopy (SEM), confocal Raman microspectroscopy (Raman), and nano-scale secondary ion mass spectrometry (NanoSIMS), we illustrate how individual cells can be thoroughly interrogated to obtain information about their taxonomic identity, structure, physiology, and metabolic activity. Analysis of an artificial community demonstrated that our correlative approach was able to resolve the activity of single cells using heavy water SIP in conjunction with Raman and/or NanoSIMS and establish their taxonomy and morphology using FISH and SEM. We then applied this workflow to a sample of yet uncultured multicellular magnetotactic bacteria. In addition to establishing their identity and activity, backscatter electron microscopy (BSE), NanoSIMS, and energy-dispersive X-ray spectroscopy (EDS) were employed to characterize the magnetosomes within the cells. By integrating these techniques, we demonstrate a cohesive approach to thoroughly study environmental microbes at single cell resolution.

Schaible, George↗

The Raman gap and collisional absorption

One of the long-standing puzzles observed in many laser-plasma experiments is the gap in the Raman backscattering spectrum. This gap is characterized by the absence of backscattered light between some critical wavelength and twice the incident laser wavelength. The latter is associated with the absolute Raman instability from the quarter-critical density surface. Supported by particle-in-cell (PIC) simulations, it is suggested that the gap can result from the collisional damping of the backscattered light. A linear analysis of the competition between the Raman growth rate and the damping rate in a non-homogenous plasma predicts the gap's existence and width as a function of the system's parameters. The theory is compared with the PIC simulations and past experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Seven-core fibre Raman laser with intercore coupling

This paper reports results of a study aimed at producing a Raman fibre laser based on a multicore fibre with high-reflectivity fibre Bragg gratings inscribed in its peripheral cores using femtosecond laser pulses. We present spectral and power characteristics of a Raman laser whose output power at a wavelength of 1090 nm is 2.5 W. The laser emission linewidth has been shown to decrease as a result of the reduction in nonlinear effects owing to the larger effective mode area in the multicore fibre in comparison with a standard single-mode fibre Raman laser. (paper)

36 MATERIALS SCIENCE↗

Video-rate Raman-based metabolic imaging by Airy light-sheet illumination and photon-sparse detection

Despite its massive potential, Raman imaging represents just a modest fraction of all research and clinical microscopy to date. This is due to the ultralow Raman scattering cross-sections of most biomolecules that impose low-light or photon-sparse conditions. Bioimaging under such conditions is suboptimal, as it either results in ultralow frame rates or requires increased levels of irradiance. Here, we overcome this tradeoff by introducing Raman imaging that operates at both video rates and 1,000-fold lower irradiance than state-of-the-art methods. To accomplish this, we deployed a judicially designed Airy light-sheet microscope to efficiently image large specimen regions. Further, we implemented subphoton per pixel image acquisition and reconstruction to confront issues arising from photon sparsity at just millisecond integrations. We demonstrate the versatility of our approach by imaging a variety of samples, including the three-dimensional (3D) metabolic activity of single microbial cells and the underlying cell-to-cell variability. To image such small-scale targets, we again harnessed photon sparsity to increase magnification without a field-of-view penalty, thus, overcoming another key limitation in modern light-sheet microscopy.

60 APPLIED LIFE SCIENCES↗

Low-frequency Raman active modes of twisted bilayer MoS 2

Abstract We study the low-frequency Raman active modes of twisted bilayer MoS 2 for several twist angles using a force-field approach and a parametrized bond polarizability model. We show that twist angles near high-symmetry stacking configurations exhibit stacking frustration that leads to significant buckling of the moiré superlattice. We find that atomic relaxation due to the twist is of prime importance. The periodic displacement of the Mo atoms shows the realization of a soliton network, and in turn, leads to the emergence of a number of frequency modes not seen in the high-symmetry stacking systems. Some of the modes are only seen in the XZ Raman polarization setup while others are seen in the XY setup. The symmetry of the normal modes, and how this affects the Raman tensors is examined in detail.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Boosting the performance of Brillouin amplification at sub-quarter-critical densities via reduction of parasitic Raman scattering

Brillouin amplification of laser pulses in plasma has been shown to be a promising approach to produce picosecond pulses of petawatt power. A key challenge is preservation of the quality of the amplified pulse, which requires control of parasitic instabilities that accompany the amplification process. At high plasma densities (> cr /4), ponderomotive filamentation has been identified as the biggest threat to the integrity of the amplifying pulse. It has therefore been proposed to perform Brillouin scattering at densities below n cr /4 to reduce the influence of filamentation. However, parasitic Raman scattering can become a problem at such densities, contrary to densities above n cr /4 where it is forbidden. In this paper, we investigate the influence of parasitic Raman scattering on Brillouin amplification at densities below n cr /4. We expose the specific problems posed by both Raman backward and forward scattering, and how both types of scattering can be mitigated, leading to an increased performance of the Brillouin amplification process.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Determining the tilt of the Raman laser beam using an optical method for atom gravimeters

The tilt of a Raman laser beam is a major systematic error in precision gravity measurement using atom interferometry. The conventional approach to evaluating this tilt error involves modulating the direction of the Raman laser beam and conducting time-consuming gravity measurements to identify the error minimum. In this work, we demonstrate a method to expediently determine the tilt of the Raman laser beam by transforming the tilt angle measurement into characterization of parallelism, which integrates the optical method of aligning the laser direction, commonly used in freely falling corner-cube gravimeters, into an atom gravimeter. A position-sensing detector (PSD) is utilized to quantitatively characterize the parallelism between the test beam and the reference beam, thus measuring the tilt precisely and rapidly. After carefully positioning the PSD and calibrating the relationship between the distance measured by the PSD and the tilt angle measured by the tiltmeter, we achieved a statistical uncertainty of less than 30 µrad in the tilt measurement. Furthermore, we compared the results obtained through this optical method with those from the conventional tilt modulation method for gravity measurement. The comparison validates that our optical method can achieve tilt determination with an accuracy level of better than 200 µrad, corresponding to a systematic error of 20 µGal in g measurement. This work has practical implications for real-world applications of atom gravimeters.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Uncertainty analysis of Raman spectra for measuring ortho-parahydrogen compositions

Determining ortho-parahydrogen compositions at cryogenic temperatures is an important quality control for liquid hydrogen custody exchange. High orthohydrogen compositions lead to an exothermic reaction resulting in increased boil off and increased venting losses of liquid hydrogen product by either the supplier or consumer. Traditional methods for measuring ortho-parahydrogen compositions such as hot-wire anemometry, nuclear magnetic resonance, and infrared spectroscopy are typically inconvenient at best. As the number of cryogenic hydrogen systems continue to increase, there is an increased need for flexible, standardized techniques for post processing composition measurements. A Raman spectrometer implemented in the Cryo-Catalysis Hydrogen Experimental Facility (CHEF) has demonstrated incredible flexibility for composition measurements of cryogenic hydrogen flows through a wide range of temperatures and pressures with the Raman probe in-situ at cryogenic temperatures. This article analyzes the uncertainty of Raman spectroscopy data of cryogenic hydrogen equilibrated at temperatures in IONEX catalyst. Spectra from hydrogen catalyzed to the equilibrium ortho-parahydrogen composition are processed and compared to expected statistical distributions for method verification.

08 HYDROGEN↗