Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “radiographs”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Optimization of DARHT Axis 1 Injector Voltage

The Dual-Axis Radiographic Hydrodynamic Test (DARHT) facility provides flash radiography capabilities using two electron Linear Induction Accelerators (LIA’s). Axis-1 of DARHT produces a 20- MeV, 2-kA, 80-ns-FWHM electron beam. The strict requirements for flash radiography require a detailed understanding of the LIA’s performance, including precision measurements of the injector electron beam energy. The technique for time resolved measurement of the electron beam energy using electron Permanent Magnet Spectrometer (ePMSpec) has been developed. The electron energy then is used to infer the voltage produced by the injector pulsed power. The injector pulsed power of DARHT I consists of a 1.5-MV, glycol-insulated Blumlein that is pulsecharged by a step-up transformer and switched by four, laser-triggered spark gaps. A series of increasing impedance transmission lines are used to transform the output voltage of the Blumlein to a maximum of 3.8MV at the diode. Figure 1a shows a graphic of the Axis-1 prime power tank, Blumlein and downstream transmission lines. The injector pulse power is designed to produce voltage on a velvet cathode located in the vacuum vessel. The specifications of the voltage-pulse flat-top over 60ns is +/-1%. A key element in the high-voltage circuit is the ethylene glycol Blumlein. The outer volume, adjacent to the laser triggered switches of the Blumlein, is a peaking capacitor. This is an independent volume that contains a mixture of ethylene glycol and water to make it an adjustable capacitor of 380 to 750 pF.

43 PARTICLE ACCELERATORS↗

Time-resolved measurement of electron beam neutralization

An intense relativistic electron beam (IREB) incident on a target generates positive ions by stimulated and thermal desorption of adsorbed gas, and subsequent electron impact ionization. These ions are accelerated upstream by the beam space-charge potential, thereby partially neutralizing the beam. If there is enough neutralization, the repulsive space-charge force can be overcome by the magnetic-pinch force due to the beam current. This so-called ion focusing is responsible for time dependent defocusing of the radiographic source spot. Since a single monolayer of adsorbed gas has a surface density of about 10 15 /cm 2 and is formed in about one second in a one micro-Torr vacuum, there is always enough adsorbed gas to make this a concern in our accelerators. Therefore, time-resolved measurements of the degree of neutralization are valuable for better understanding of this process with an eye to mitigation for improvement of our radiography. Moreover, these measurements would aid quantification of uncertainties due to these effects when using invasive beam diagnostics, such as OTR imaging targets.

43 PARTICLE ACCELERATORS↗

Developing inductively driven diagnostic X-ray sources to enable transformative radiography and diffraction capabilities on Z

Penetrating X-rays are one of the most effective tools for diagnosing high energy density experiments, whether through radiographic imaging or X-ray diffraction. To expand the X-ray diagnostic capabilities at the 26-MA Z Pulsed Power Facility, we have developed a new diagnostic X-ray source called the inductively driven X-pinch (IDXP). This X-ray source is powered by a miniature transmission line that is inductively coupled to fringe magnetic fields in the final power feed. The transmission line redirects a small amount of Zs magnetic energy into a secondary cavity where 150+ kA of current is delivered to a hybrid X-pinch. In this report, we describe the multi-stage development of the IDXP concept through experiments both on Z and in a surrogate setup on the 1 MA Mykonos facility. Initial short-circuit experiments to verify power ow on Z are followed by short-circuit and X-ray source development experiments on Mykonos. The creation of a radiography-quality X-pinch hot spot is verified through a combination of X-ray diode traces, laser shadowgraphy, and source radiography. The success of the IDXP experiments on Mykonos has resulted in the design and fabrication of an IDXP for an upcoming Z experiment that will be the first-ever X-pinch fielded on Z. We have also pursued the development of two additional technologies. First, the extended convolute post (XCP) has been developed as an alternate method for powering diagnostic X-pinches on Z. This concept, which directly couples the current owing in one of the twelve Z convolute posts to an X-pinch, greatly increases the amount of available current relative to an IDXP (900 kA versus 150 kA). Initial short-circuit XCP experiments have demonstrated the efficacy of power ow in this geometry. The second technology pursued here is the inductively driven transmission line (IDTL) current monitor. These low-current IDTLs seek to measure the current in the final power feed with high fidelity. After three generations of development, IDTL current monitors frequently return cleaner current measurements than the standard B-dot sensors that are fielded on Z. This is especially true on high-inductance experiments where the harshest conditions are created in the nal power feed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Preshot Report for the NIF DDCyl Campaign: H_Hyd_DDCyl_DRT_AAA/BBB/CCC

The first two cylinder shot days on the National Ignition Facility, allocated through the Discovery Science program, provided a successful demonstration of the cylinder platform on the NIF. Both of these shot days used cylinders that were nominally 3 times larger in radial dimension than cylinders fielded at the OMEGA laser facility, here referred to as scale-3 targets. In the first Discovery Science shot day, we demonstrated that Rayleigh-Taylor instability growth during the deceleration phase is scale-invariant between the scale-1 OMEGA experiments and similarly tailored scale-3 NIF experiments at the same convergence ratio of CR=initial radius/final radius=2.25. In the second Discovery Science shot day, we increased the convergence ratio by lowering the density of the central foam from 300 mg/cm 3 to roughly 40 mg/cm 3 with the same laser drive, resulting in a higher CR=5 at the time when the rebounding shock strikes the aluminum marker. We also greatly improved the imaging setup for the second shot day, resulting in much higher quality (greater signal-to-noise) radiographs of the implosion. This current shot day was awarded through the High Energy Density (HED) Council, following this demonstration of platform viability. It was originally scheduled for June 2020, but it was postponed several times due to the COVID-19 pandemic. It is currently scheduled for January 6, 2021. For this shot day, we will increase the radial dimension of the cylinder to four times the OMEGA-scale targets, and these will be referred to as scale-4 cylinders. Increasing the radial dimension of the target is advantageous as we push these targets to higher convergence ratio. By starting with an initially larger target, the target can push to a higher CR while maintaining the same final viewing area. Other than the larger radial dimension, the targets are very similar in design to the previous ones, consisting of an epoxy ablator, an embedded aluminum marker layer, and a low density central CH foam. These will also use a 40 mg/cm3 CH foam, reaching a CR~4.5 with the same laser energy (the added target mass reduces the final CR slightly). Note that this is NOT designed to be scale-invariant with the previous scale-1 OMEGA and scale-3 NIF shots. It was determined that the laser energy required to achieve a scale-invariant implosion was above the allowable optics damage limits (though achievable on the NIF) for these scale-4 targets.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Plasma Photonics: Manipulating Light Using Plasmas (Full Technical Final Report)

In this LDRD, we made significant advances on multiple fronts on the investigation and design of plasma-based optical structures to manipulate light at extreme intensities. We have unveiled new fundamental properties of laser-plasma interaction that were leveraged to introduce transformative applications. We first investigated new ways to generate high-amplitude plasma-based optical structures, based on the auto-resonance mechanism in order to produce refractive structures in plasmas. New insights into the interaction of such plasma structures with light waves allowed us to propose new methods for polarization manipulation and control for high-intensity lasers in the nonlinear regime, i.e. allowing the manipulation of an intense laser via its interaction with a less intense “control” laser beam in plasmas. Another application that we demonstrated experimentally is the capability to manipulate the velocity of light waves in plasmas by tailoring its refractive index; we reported the first demonstration of “slow light” and supra-luminal light propagation in plasmas. We also developed a new technological concept that would allow the probing of the type of plasma structures investigated in such applications, using high-bandwidth laser probing [Ludwig Phys. Plasmas 2019]. Finally, first steps were taken towards the demonstration of a plasma-based amplifier and compressor for the National Ignition Facility, in order to achieve powers equal of greater than those delivered by the Advanced Radiographic Capability (ARC). This technique uses a plasma-based grating acting like a compressor and amplifier, which could potentially compress and amplify an 88 ps, 56 J beam from the National Ignition Facility to <10 ps and hundreds of J.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Progress on Associate-Particle Imaging Algorithms, 2020

The present work describes progress on the development of imaging algorithms that use fast neutron signatures acquired using the associated-particle imaging (API) method. The present work complements ongoing work to develop neutron source and detector hardware to enable field inspection by investigating algorithms that are capable of discriminating between critical materials or extracting three-dimensional geometrical information from single-sided or transmission measurements. The present work is divided into three approaches:(1)Iterative reconstruction of inelastic gamma-ray emissions to perform three-dimensional time-of-flight imaging in a single view in either transmission or backscatter configurations. Iterative reconstruction enables image resolution better than the inherent TOF resolution.(2)Decomposition of registered neutron and x ray radiographs into an assumed material list for each pixel in the image.(3)Material identification using full spectral analysis that includes the emergent neutron and gamma ray energies, times, and angles.Progress for each approach is summarized for fiscal year 2020.

97 MATHEMATICS AND COMPUTING↗

Cathode to Target Simulations for Scorpius: I. Simulation Codes and Models

The new Scorpius linear induction electron accelerator is under development for multi-pulse flash radiography of large, explosively-driven hydrodynamic experiments. Beam physics from the cathode to the target was examined with computer simulations, including envelope, ray-trace, and particle-in cell (PIC) codes. Beam instabilities investigated included beam breakup (BBU), image displacement, diocotron, parametric envelope, ion hose, and the resistive wall instability. Beam corkscrew motion and emittance growth from beam mismatch were also studied. The results of these simulations is documented in a series of reports. In this report the computer codes and physical models used for these simulations are described. The conclusion of this study is that Scorpius will produce and accelerate a beam with radiographic quality equivalent to the present accelerators at Los Alamos National Laboratory if the same engineering standards and construction details are upheld.

43 PARTICLE ACCELERATORS↗

Re-Analysis of DARHT Axis 2 S4 Magnet Sweep Measurements

The Dual-Axis Radiographic Hydrodynamic Test (DARHT) facility provides flash radiography capabilities using two electron Linear Induction Accelerators (LIA’s). Understanding fundamental properties of the electron beams is essential to optimizing spot size and dose for radiography. This work describes distribution measurements of a single-kicked electron beam (16.5MeV, 1.7kA, 60ns) at a location downstream at imaging station C on DARHT Axis 2. The beam at station C is focused by the S4 solenoid located upstream. The beam distribution is measured by imaging optical transition radiation (OTR) from electrons striking a 51-µm thick titanium foil. This data and analysis were originally published by Ekdahl. The results here are a re-analysis of the asymmetric halo emittance contribution as compared to the emittance resulting from the FWHM of the distribution. This is accomplished using xtr2 fits to the data which include non-linear magnetic field effects in S4. Also examined are the calculated S4 spherical aberration contributions to the emittance using xtr.

43 PARTICLE ACCELERATORS↗

(U) Segmented Scintillator Pitch, Thickness, and Septa Material Effects on the Swank Factor, Quantum Efficiency, and DQE(0) for High-Energy X-Ray Radiography

Scintillator design is an important aspect in constructing a radiographic facility in order to collect the most robust data possible. For the proposed Enhanced Capabilities for Sub-critical Experiment (ECSE) facility in Nevada, we explored a permutation of 13 segmented scintillator designs in order to understand the best performance and trade offs for each design. We calculated the quantum efficiency, Swank factor, and detective quantum efficiency at zero-frequency (DQE(0)) for each scintillator design in order to compare performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Estimating Beam-Target Heating

At Los Alamos National Laboratory, two high-current linear induction accelerators (LIAs) are used to produce bremsstrahlung source spots for flash radiography of high-explosive driven hydrodynamic experiments at the Dual Axis Radiographic Hydrodynamic Test (DARHT) facility. Measurements of the electron-beam current density profile are valuable for understanding the beam dynamics in order to improve the quality of the radiography source spot. A technique commonly used at DARHT is to image the profile in Cerenkov or Optical Transition Radiation (OTR) light created by the beam striking a thin target inserted into the beam line. Target materials include aluminized dielectrics and titanium foils for OTR, and fused silica wafers for Cerenkov radiation. A practical complication with this technique is heating of the target by the electron beam. If the beam density is too great, the target can be destroyed. Moreover, even if the beam density is kept low enough to be nondestructive, the beam can heat the target to a high enough temperature to desorb gas from the surface. In that case, direct impact ionization of the gas by beam electrons can partially neutralize the beam, causing it to over-focus, thereby spoiling the data, if not destroying the target. The purpose of this note is to review some of the fundamental physics of electron beam heating in order to provide some elementary guidance for design of these imaging experiments to avoid overheating the target. Some specific examples for materials that we often use for imaging targets and beam-target experiments are provided.

43 PARTICLE ACCELERATORS↗

Imaging Station Multi-Foil Target

The Axis II Downstream Transport (DST) of the Dual Axis Radiographic Hydrodynamic Testing (DARHT) Facility is the final subassembly of the particle accelerator whose primary objective is to focus the 4-pulse beam as it enters the Target Region. Before the beam reaches the Target Region, it passes through two imaging stations located in the DST. At Imaging Station E (ISE) and Imaging Station C (ISC), diagnostics are conducted and experimenters study beam physics using specialized targets. Different targets are used depending on the objective of the study. The desire to conduct specific experiments has driven a need for a multi-foil target. This new design has been engineered to allow for new capabilities, and diagnostics to be studied at ISC. To accommodate new parameters, three different configurations have been conceived. Although each of the three designs differ from each other, their function and purpose remain consistent. Each target is engineered to secure a variable amount of target foils at variable spacing while Imaging Station experiments are conducted. Beam diagnostics and data from the targets are analyzed through various sized viewports on the imaging stations. The objective of this technical note is to document the purpose and functionality of the targets. Design considerations, assembly instructions, and maintenance recommendations are also discussed. Additionally, each target and its respective advantages and disadvantages are covered in detail.

43 PARTICLE ACCELERATORS↗

Transient Deformation in Additively Manufactured 316L Stainless Steel Lattices Characterized with in-situ X-ray Phase Contrast Imaging: The Complete Dataset for Three Geometrical Lattices

Metallic lattice structures are being considered for shock mitigation applications due to their superior mechanical properties, energy absorption capability and lightweight characteristics inherent of the additive manufacturing process. In this study, shock compression experiments coupled to x-ray phase contrast imaging (PCI) were conducted on 316L stainless steel lattices. Meso-scale simulations incorporating the as-built lattice structure characterized by computed tomography were used to simulate PCI radiographs in CTH for direct comparison to experimental data. The methodology presented here offers robust validation for constitutive properties to further our understanding of lattice compaction at application-relevant strain rates.

36 MATERIALS SCIENCE↗

High Fidelity Tomographic Density Reconstructions [Slides]

Pressed high explosives have small density variations associated with the pressing process, from a few to sub percent depending on the material. Variations at these levels are known to have an impact on HE performance. Currently, a destructive testing method based on physical sectioning followed by immersion density measurements (slice and dice) is utilized. However, this method has poor spatial resolution limited by the the sectioning size, 1-2 cm. If possible, radiographic methods including Computed Tomography (CT) would be preferred, as they are non-destructive and have higher (less than .1 mm) spatial resolution. However, beam hardening, scattered radiation, and detector effects make density reconstructions at this level extremely challenging.

42 ENGINEERING↗

Beam Stability Overview [Slides]

Radiographic spot size is affected by many factors, including beam motion due to instabilities. Instabilities and effects that can influence the radiation-source spot size are being evaluated for the Scorpius flash-radiography accelerator. The Scorpius LIA design has a direct influence on beam stability. Many features of the design were specifically incorporated to mitigate instability. The major beam dynamics concerns for high-current LIAs are being evaluated for the long, 102-cell Scorpius design. For these results, all tools available were used including experimental data, analytic theory, and physics simulation codes.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Multi-Probe Campaign FY23 Omega EP Shot Request [Slides]

The goal of the Multi-Probe experimental campaign is to assess the feasibility of using multiple probe types (x ray, proton, neutron, and electron) in future LANL radiographic facilities. The experiments proposed for FY23 will begin developing a neutron source for radiography at Omega EP.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First Results from Diamagnetic Loop Measurements of the DARHT-I Electron Beam [Slides]

Diamagnetic-loop (DML) measurements can inform efforts to improve radiographic resolution. DML is non-invasive, so time-resolved data is available on every shot while tuning or executing a hydrotest. The time-resolved beam size can be deduced from the DML data. LIA beam-transport dynamics affecting beam size can be monitored while testing mitigation measures (e.g., beam halo suppression). Time-resolved beam size at final focus provides immediate information about spot size enlargement due to blur, and effectiveness of mitigation efforts. DML measures magnetic flux produced by a rotating beam, so it also enables monitoring of Larmor emittance that can enlarge the spot size. Beam rotation adds in quadrature with emittance, hence “Larmor emittance." Observing zero bias-field DML flux monitors beam rotation resulting from imperfect nulling of flux linking the cathode, and/or broken LIA transport symmetry (e.g., steering, quads, etc.).

43 PARTICLE ACCELERATORS↗

Health Assessment and Performance Monitoring of Large Machine Diagnostics

Presentation to be given at the CCS-6 Statistical Seminar Series. Regularly maintained and operated diagnostic machines are a backbone of data collection and are a vital component of the Stockpile Stewardship Program’s efforts to better understand nuclear physics. The Cygnus X-ray machine, stationed at the Nevada National Security Site’s U1a underground facility, is one such diagnostic that provides a radiographic capability for the subcritical experiment program. Component failures within Cygnus can result in catastrophic downtime for the diagnostic, affecting performance, schedules, and cost. However, over the years various measurements have been collected on the two Cygnus axes, including voltage and current measurements at different locations, which we believe have predictive power to indicate machine health. We will share preliminary insight into this data and the machine learning approaches we are taking to assess Cygnus’ health, observe declining performance, and predict failures.

97 MATHEMATICS AND COMPUTING↗

DARHT Overview [Slides]

DARHT is a key facility for Stockpile Stewardship. Dual Axis Radiographic Hydrodynamic Test Facility - World-class X-ray radiography for dynamic non-nuclear tests.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗