Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “radiographs”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Automatic Welding of Stainless Steel Tubing

To determine if the use of automatic welding would allow reduction of the radiographic inspection requirement, and thereby reduce fabrication costs, a series of welding tests were performed. In these tests an automatic welder was used on stainless steel tubing of 1/2, 3/4, and 1/2 inch diameter size. The optimum parameters were investigated to determine how much variation from optimum in machine settings could be tolerate and still result in a good quality weld. The process variables studied were the welding amperes, the revolutions per minute as a function of the circumferential weld travel speed, and the shielding gas flow. The investigation showed that the close control of process variables in conjunction with a thorough visual inspection of welds can be relied upon as an acceptable quality assurance procedure, thus permitting the radiographic inspection to be reduced by a large percentage when using the automatic process.

Clautice, W. E.↗

X-ray beam pointer

Inexpensive, readily assembled pointer aims X-ray machine for welded assembly radiographs. Plumb bob used for vertical alinement and yardstick used to visualize X-ray paths were inconvenient and inaccurate. Pointer cuts alinement time by one-half and eliminates necessity of retakes. For 3,000 weld radiographs, pointer will save 300 worker-hours and significant materials costs.

Nelson, C. W.↗

Tensile stress-strain behavior of hybrid composite laminates

A study was made of the stress-strain response of several hybrid laminates, and the damage was correlated with nonlinear stress-strain response and ultimate strength. The fibers used in the laminates were graphite, S-glass, and Kevlar. Some laminates with graphite fibers had perforated Mylar film between plies, which lowered the interlaminar bond strength. The laminate configurations were chosen to be like those of buffer strips in large panels and fracture coupons. Longitudinal and transverse specimens were loaded in tension to failure. Some specimens were radiographed to reveal damage due to edge effects. Stress-strain response is discussed in terms of damage shown by the radiographs. Ultimate strengths are compared with simple failure criteria, one of which account for damage.

Kennedy, J. M.↗

Development and applications of nondestructive evaluation at Marshall Space Flight Center

A brief description of facility design and equipment, facility usage, and typical investigations are presented for the following: Surface Inspection Facility; Advanced Computer Tomography Inspection Station (ACTIS); NDE Data Evaluation Facility; Thermographic Test Development Facility; Radiographic Test Facility; Realtime Radiographic Test Facility; Eddy Current Research Facility; Acoustic Emission Monitoring System; Advanced Ultrasonic Test Station (AUTS); Ultrasonic Test Facility; and Computer Controlled Scanning (CONSCAN) System.

Whitaker, Ann F.↗

Positioning Fixtures For X-Ray Inspection

Flanged fixtures designed to position x-ray source at fixed locations within welded parts inspected radiographically. Eliminates need for tedious measurements to find proper locations and alignments of x-ray source. Reduces setup time and eliminates waste of film occurring when x-radiographs taken at incorrect positions. Variability among parts, inspectors, and shifts eliminated. Each fixture essentially flanged plastic cylinder holding x-ray tube on its axis. Fixture designed to fit specific part to hold x-ray source at internal position from which x rays are required to emanate to illuminate region of interest.

Lee, Jerry W.↗

Experiment M-6: Bone Demineralization

Densitometric evaluations of serial radiographs of "normal" subjects have often shown rather frequent changes in bone mass within relatively short periods of time. For this reason it was decided to make two pre-flight and two post flight radiographs of the Gemini V backup crew. In comparing the changes observed preflight and post flight as the conventional os calcis scanning site between the two crews, it was found that no changes greater than 4 percent were evident in either member of the backup crew. In comparing the changes observed preflight and postflight as the conventional o calcis scanning site between the two crews, it was found that no changes greater than 4 percent were evident in either member of the backup crew. This is in contract to the 15.1 and 8.9 percent losses observed in the prime crew. It has long been known that the skeletal system experiences a general loss of mineral under immobilization or extended bed rest. However, in both Gemini IV and Gemini V studies, bone mass losses were greater in both the os calcis and phalanx than were shown by the TWU bed-rest subjects during the same period of time. Although the bone mass losses in the 8-day Gemini V flight were generally greater than in the 4-day Gemini IV flight, the information to date is still insufficient to conclude that the losses tend to progress linearly with time, or whether a form of physiological adaptation may occur in longer space flights.

Mack, Pauline B.↗

Fractal dimension analysis of weight-bearing bones of rats during skeletal unloading

Fractal analysis was used to quantify changes in trabecular bone induced through the use of a rat tail-suspension model to simulate microgravity-induced osteopenia. Fractal dimensions were estimated from digitized radiographs obtained from tail-suspended and ambulatory rats. Fifty 4-month-old male Sprague-Dawley rats were divided into groups of 24 ambulatory (control) and 26 suspended (test) animals. Rats of both groups were killed after periods of 1, 4, and 8 weeks. Femurs and tibiae were removed and radiographed with standard intraoral films and digitized using a flatbed scanner. Square regions of interest were cropped at proximal, middle, and distal areas of each bone. Fractal dimensions were estimated from slopes of regression lines fitted to circularly averaged plots of log power vs. log spatial frequency. The results showed that the computed fractal dimensions were significantly greater for images of trabecular bones from tail-suspended groups than for ambulatory groups (p < 0.01) at 1 week. Periods between 1 and 4 weeks likewise yielded significantly different estimates (p < 0.05), consistent with an increase in bone loss. In the tibiae, the proximal regions of the suspended group produced significantly greater fractal dimensions than other regions (p < 0.05), which suggests they were more susceptible to unloading. The data are consistent with other studies demonstrating osteopenia in microgravity environments and the regional response to skeletal unloading. Thus, fractal analysis could be a useful technique to evaluate the structural changes of bone.

Non-NASA Center↗

An Analysis of Nondestructive Evaluation Techniques for Polymer Matrix Composite Sandwich Materials

Structural sandwich materials composed of triaxially braided polymer matrix composite material face sheets sandwiching a foam core are being utilized for applications including aerospace components and recreational equipment. Since full scale components are being made from these sandwich materials, it is necessary to develop proper inspection practices for their manufacture and in-field use. Specifically, nondestructive evaluation (NDE) techniques need to be investigated for analysis of components made from these materials. Hockey blades made from sandwich materials and a flat sandwich sample were examined with multiple NDE techniques including thermographic, radiographic, and shearographic methods to investigate damage induced in the blades and flat panel components. Hockey blades used during actual play and a flat polymer matrix composite sandwich sample with damage inserted into the foam core were investigated with each technique. NDE images from the samples were presented and discussed. Structural elements within each blade were observed with radiographic imaging. Damaged regions and some structural elements of the hockey blades were identified with thermographic imaging. Structural elements, damaged regions, and other material variations were detected in the hockey blades with shearography. Each technique s advantages and disadvantages were considered in making recommendations for inspection of components made from these types of materials.

Cosgriff, Laura M.↗

Corrosion Inhibitors as Penetrant Dyes for Radiography

Liquid/vapor-phase corrosion inhibitors (LVCIs) have been found to be additionally useful as penetrant dyes for neutron radiography (and perhaps also x-radiography). Enhancement of radiographic contrasts by use of LVCIs can reveal cracks, corrosion, and other defects that may be undetectable by ultrasonic inspection, that are hidden from direct optical inspection, and/or that are difficult or impossible to detect in radiographs made without dyes.

Novak, Howard L.↗

Deep Mapping of Small Solar System Bodies with Galactic Cosmic Ray Secondary Particle Showers

We will investigate the use of galactic cosmic ray (GCR) secondary particles to probe the deep interiors of small solar system bodies (SSBs), including comets, asteroids, and geologic structures on the surfaces of airless bodies. Applications include solar system science, planetary defense, and resource utilization. Our Phase I study demonstrated that muons, the long-range charged component of GCR showers, can penetrate SSBs up to a km in diameter, providing information on their interior structure. Muons produced in Earth’s atmosphere have been applied to image the interior of large objects for science and engineering. In Phase I, we found that the production of muons in the solid surfaces of airless bodies is much smaller than in Earth’s atmosphere. Nevertheless, the flux of transmitted muons is sufficient to detect inclusions within an asteroid or comet in a reasonable amount of time, ranging from hours to weeks, depending on the size of the SSB and the density contrast, position and size of the inclusion. For asteroids and comets, large density variations (e.g., porous soil or ice versus solid rock) are relatively easy to detect. The intrinsic spatial resolution of muon radiography (“muography”) is on the scale of a few meters. The spatial resolution that can be achieved in practice depends on signal intensity and integration time (counting statistics), the angular resolution of the muon tracker (hodoscope) and details of data reduction and analysis methodology. Our Phase II project will assess remaining unknowns for the application of muography to determining the interior structure of SSBs, assess risks for implementation, and provide a roadmap for development of SSB muography beyond the NIAC program. To achieve our objectives, we will focus on four interrelated tasks: Task1) Signal and background characterization: Characterize the production and transmission of muons and secondary particle backgrounds made by cosmic ray showers in SSBs; and near-surface features from radiographic and tomographic data; Task2) Imaging studies: Develop methods to determine the density structure of SSB interiors and near-surface features from radiographic and tomographic data; Task3) Instrument design: Using simulations and bench-top laboratory experiments, investigate specific concepts for the design of compact hodoscopes and components; Task4) Synthesis: Combine the results of the first three tasks to determine the range of applicability of the method, identify the steps needed for maturation of the concept, and explore concepts for a pilot muography mission.

Prettyman, Thomas H.↗

Automated Registration of Multi-Mode Nondestructive Evaluation Data

Registration techniques play a central role in applications of image processing to computer vision, medical imaging, and automatic target tracking. Feature-based techniques such as scale-invariant feature transform (SIFT) and speeded up robust features (SURF) are commonly used to register images derived from a single modality. However, SIFT and SURF struggle to register images from different modalities because the features tend to manifest rather differently and at sometimes very different length-scales. The most successful methods that have been developed to register multi-modal data use information-theoretic approaches. These methods play a key part in nondestructive evaluation scenarios where data that is collected by sensors of different modalities must be registered to be fused. In this paper, automated registration based on normalized mutual information is applied to align data derived from ultrasonic and radiographic inspections of (i) additively manufactured titanium alloy test coupons, and (ii) thin, lithium metal pouch-cell batteries. The quality of the registration is quantified in terms of computational resources and spatial accuracy. In the first case the X-ray computed tomography (XCT) data is captured on a region corresponding to a small subset of the ultrasonic data, while in the case of the lithium batteries the digital radiography (DR) captures a larger region of interest than the ultrasonic data. In both cases the radiographic data resolution is much higher than for ultrasound, but interestingly, in both cases the accuracy of the registration is approximately equal to two-to-three-pixel lengths in the ultrasonic images.

Nondestructive Evaluation↗

Optical Relays for Imaging Scintillators

Cygnus is a dual beam high-energy radiographic x-ray source. Ten years ago, three large zoom lenses were assembled to collect images from 200 mm x 200 mm square scintillators. The zoom capability allows zooming down to a 60 mm x 60 mm picture from the scintillator. Current radiographic imaging needs now require larger 270 mm x 270 mm square scintillators and the capability to use both 92 mm x 92 mm and 62 mm x 62 mm CCD cameras, and a new lens design to meet these needs. This zoom lens incorporates 11 elements and is designed to be telecentric. It images a scintillator emitting light peaking at 435 nm, so special glass types are required for the lens elements. Much larger elliptical pellicles are needed to deflect the scintillator light out of the x-ray path into the lens. The optical axis of the imaging system must be colinear with the x-ray axis. Two scintillators are positioned in each of two Cygnus x-ray axes, for a total of four scintillators and four lens systems. An optional configuration will be shown, enabling two lens systems imaging opposite sides of a single scintillator, for a total of four lenses and two scintillators. Although this configuration has advantages, it suffers from crosstalk. Care must be taken to analyze the anti-reflection coatings applied to all the elements in the imaging chain, including the CCD array and

62 RADIOLOGY AND NUCLEAR MEDICINE↗

New Design Yields Robust Large-Area Framing Camera

Manuscript to be submitted to Review of Scientific Instruments to determine interest in possible publication. Website: https://aip.scitation.org/rsi/authors/manuscript High-speed imaging is a core diagnostic capability for the Nevada National Security Site (NNSS). Data from experiments that measure the behavior of materials under extreme conditions are essential for the stockpile mission. For example, during subcritical experiments, materials that are shocked and compressed under high-explosive drive change behavior rapidly over timescales measured in millionths or even billionths of a second. Characterizing and understanding this behavior requires radiographic and/or optical imaging to track motion on these timescales. Framing cameras provide a discrete series of images over a short period of time in a manner that mimics a high-speed movie camera, but with individual shutter times that must be extremely short in order to capture freeze-frame images of rapidly evolving phenomena such as high-explosive shock-driven ejecta, dynamic compression of metals, and high-velocity fluid flow.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ultrasonic Testing (UT) Reference Standard for Additive Manufacturing Quality Control

Many additive manufacturing (AM) reference standards for build quality verification concentrate primarily on external features. In contrast, EPRI proposes a pair of AM reference blocks that feature only internal and embedded forms. This report presents, collates, and discusses quantitative nondestructive evaluation (NDE) results from various techniques, including visual testing (VT), radiographic testing (RT), conventional ultrasonic testing (UT), and full matrix capture/total focusing method (FMC/TFM) scanning. The blocks are intended, as part of a larger series of blocks, to evaluate build quality and the relative performance of different NDE techniques in detecting various features. The limits of detectability and the closeness of the as-built shape to the intended form for certain features are quantified, facilitating direct comparison. Upon analysis of the results of this testing, it was found that FMC/TFM was consistently superior in detection, followed by conventional UT, then VT, and lastly RT.

36 MATERIALS SCIENCE↗

How much have adverse occupational health outcomes among construction workers improved over time? Evidence from 25 years of medical screening

Background Construction workers have always had a high risk of occupational illnesses. We used 25 years of data from a medical screening program serving older construction workers to determine how much health outcomes have improved over the past 60 years. Methods We investigated changes in relative risk for chest radiographs consistent with pneumoconiosis, COPD by spirometry, lung cancer mortality, and audiometry-assessed hearing impairment among workers participating in a medical screening program. Results were stratified by decade of first construction employment: before 1960, 1960–1969, 1970–1979, 1980–1989, and after 1990. Poisson and Cox regression analyses assessed relative risk by decade adjusted for age, sex, smoking, and years of construction trade work. Results Subjects were 94% male and, on average, 60 years old with 25 years of construction work. When compared to workers employed before 1960, those first employed after 1990 experienced the following reductions in model-adjusted relative risks: chronic obstructive pulmonary disease, 32%; all pneumoconiosis, 68%; parenchymal abnormalities, 35%; pleural abnormalities, 71%; hearing impairment, 20%; and lung cancer mortality, 48%. Risks started to decline in the 1960s with greatest reductions among workers first employed after 1970. Conclusions This study demonstrates the positive impact that adoption of occupational health protections have had over the past 60 years. The greatest risk reductions were observed for outcomes with strong regulatory and legal incentives to reduce exposures and associated risks, such as those associated with inhalation hazards (asbestos and silica), while lowest improvement was for hearing impairment, for which little regulatory enforcement and few prevention incentives have been adopted.

60 APPLIED LIFE SCIENCES↗

Artificial intelligence to unlock real-world evidence in clinical oncology: A primer on recent advances

Purpose: Real world evidence is crucial to understanding the diffusion of new oncologic therapies, monitoring cancer outcomes, and detecting unexpected toxicities. In practice, real world evidence is challenging to collect rapidly and comprehensively, often requiring expensive and time-consuming manual case-finding and annotation of clinical text. In this Review, we summarise recent developments in the use of artificial intelligence to collect and analyze real world evidence in oncology. Methods: We performed a narrative review of the major current trends and recent literature in artificial intelligence applications in oncology. Results: Artificial intelligence (AI) approaches are increasingly used to efficiently phenotype patients and tumors at large scale. These tools also may provide novel biological insights and improve risk prediction through multimodal integration of radiographic, pathological, and genomic datasets. Custom language processing pipelines and large language models hold great promise for clinical prediction and phenotyping. Conclusions: Despite rapid advances, continued progress in computation, generalizability, interpretability, and reliability as well as prospective validation are needed to integrate AI approaches into routine clinical care and real-time monitoring of novel therapies.

60 APPLIED LIFE SCIENCES↗

Gamma-Ray and Cosmic Ray Muon Modalities for Cargo Inspection

Screening and inspection of cargo containers are two essential methods to nondestructively examine the contents of shipment. These methods enable the detection of illicit transportation of unauthorized materials such as nuclear and radioactive materials, explosives, drugs, and so on, typically at borders or secure facilities. Although high-energy X-ray transmission is a standard system and is widely used for cargo inspection, the inherent challenges of high false-positive rates and high attenuation factors necessitate the development of complementary techniques that can increase the detection efficiency and accuracy in large and dense materials. Gamma-rays, which possess higher penetration characteristics because of their high energy, offer an alternative nonintrusive modality for cargo scanning. They represent a promising inspection method when compared to X-rays for three reasons: (1) improved ability to detect nuclear and radioactive materials, (2) higher inspection throughput rates, and (3) lower false-positive rates. Currently, there are two main gamma-ray inspection techniques, active and passive interrogation. Active interrogation can be further grouped into (1) gamma-ray transmission imaging and (2) neutron-induced gamma-ray emission detection. Gamma-ray transmission imaging utilizes differences in material densities for mapping the shipment contents and detecting anomalies. It is analogous to the X-ray transmission method; however, the high-energy photons make it more difficult to shield against, which enables more efficient performance in large and dense material inspection. Neutron-induced gamma-ray emission inspection is designed for the detection of nuclear and radioactive material because those materials emit characteristic gamma-rays when they are activated by neutron absorption. On the other hand, passive interrogation techniques rely on high-efficiency detectors to detect radiation emitted from hidden special nuclear or other radioactive materials. Similar to passive interrogation, cosmic ray muon monitoring and imaging are relatively new techniques that do not require external radioactive sources. These techniques have received attention as a potential next-generation radiographic probe to identify illicit transportation of nuclear and radioactive materials in cargo containers. Cosmic ray muons have unique features, (1) much higher energies than X-rays or gamma-rays (on the order of 10−1—104 GeV), (2) enhanced penetration capability, and (3) natural occurrence, thereby eliminating the need for induced radiation sources. These features enable cosmic ray muons to be utilized for detection of special nuclear materials in high-background-noise environments. By analyzing incoming and outgoing muon trajectories, scattering angles, and energies, it has been shown that it would be possible to locate hidden and well-shielded materials in cargo containers via three-dimensional muon tomography images or signal analysis. Gamma-rays, cosmic ray muons, and other nonintrusive cargo inspection modalities are complementary to each other, allowing them to address various cargo inspection conditions (i.e., scanning time, cost, radiation exposure level, and types of target materials). This chapter presents a detailed review of the theoretical fundamentals and technical principles behind the current gamma-ray and cosmic ray muon modalities for cargo inspection. Additionally, critical assessments and suggestions for the future directions to advance the use of gamma and muon modalities are discussed.

Bae, Junghyun↗

Out-of-Distribution Detection and Radiological Data Monitoring Using Statistical Process Control

Abstract Machine learning (ML) models often fail with data that deviates from their training distribution. This is a significant concern for ML-enabled devices as data drift may lead to unexpected performance. This work introduces a new framework for out of distribution (OOD) detection and data drift monitoring that combines ML and geometric methods with statistical process control (SPC). We investigated different design choices, including methods for extracting feature representations and drift quantification for OOD detection in individual images and as an approach for input data monitoring. We evaluated the framework for both identifying OOD images and demonstrating the ability to detect shifts in data streams over time. We demonstrated a proof-of-concept via the following tasks: 1) differentiating axial vs. non-axial CT images, 2) differentiating CXR vs. other radiographic imaging modalities, and 3) differentiating adult CXR vs. pediatric CXR. For the identification of individual OOD images, our framework achieved high sensitivity in detecting OOD inputs: 0.980 in CT, 0.984 in CXR, and 0.854 in pediatric CXR. Our framework is also adept at monitoring data streams and identifying the time a drift occurred. In our simulations tracking drift over time, it effectively detected a shift from CXR to non-CXR instantly, a transition from axial to non-axial CT within few days, and a drift from adult to pediatric CXRs within a day—all while maintaining a low false positive rate. Through additional experiments, we demonstrate the framework is modality-agnostic and independent from the underlying model structure, making it highly customizable for specific applications and broadly applicable across different imaging modalities and deployed ML models.

Zamzmi, Ghada↗