Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “radiographic imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

280 records · Page 16

Quantitative 3-D imaging topogrammetry for telemedicine applications

The technology to reliably transmit high-resolution visual imagery over short to medium distances in real time has led to the serious considerations of the use of telemedicine, telepresence, and telerobotics in the delivery of health care. These concepts may involve, and evolve toward: consultation from remote expert teaching centers; diagnosis; triage; real-time remote advice to the surgeon; and real-time remote surgical instrument manipulation (telerobotics with virtual reality). Further extrapolation leads to teledesign and telereplication of spare surgical parts through quantitative teleimaging of 3-D surfaces tied to CAD/CAM devices and an artificially intelligent archival data base of 'normal' shapes. The ability to generate 'topogrames' or 3-D surface numerical tables of coordinate values capable of creating computer-generated virtual holographic-like displays, machine part replication, and statistical diagnostic shape assessment is critical to the progression of telemedicine. Any virtual reality simulation will remain in 'video-game' realm until realistic dimensional and spatial relational inputs from real measurements in vivo during surgeries are added to an ever-growing statistical data archive. The challenges of managing and interpreting this 3-D data base, which would include radiographic and surface quantitative data, are considerable. As technology drives toward dynamic and continuous 3-D surface measurements, presenting millions of X, Y, Z data points per second of flexing, stretching, moving human organs, the knowledge base and interpretive capabilities of 'brilliant robots' to work as a surgeon's tireless assistants becomes imaginable. The brilliant robot would 'see' what the surgeon sees--and more, for the robot could quantify its 3-D sensing and would 'see' in a wider spectral range than humans, and could zoom its 'eyes' from the macro world to long-distance microscopy. Unerring robot hands could rapidly perform machine-aided suturing with precision micro-sewing machines, splice neural connections with laser welds, micro-bore through constricted vessels, and computer combine ultrasound, microradiography, and 3-D mini-borescopes to quickly assess and trace vascular problems in situ. The spatial relationships between organs, robotic arms, and end-effector diagnostic, manipulative, and surgical instruments would be constantly monitored by the robot 'brain' using inputs from its multiple 3-D quantitative 'eyes' remote sensing, as well as by contact and proximity force measuring devices. Methods to create accurate and quantitative 3-D topograms at continuous video data rates are described.

Altschuler, Bruce R.↗

Accelerated radiation transport modeling techniques for pencil beam computed tomography using gamma rays

Monte Carlo radiation transport modeling studies were performed for a compact, and high-resolution gamma-ray computed tomography system designed for imaging irradiated nuclear fuel. The system comprises a 60 Co source – chosen for its highly penetrating 1173 keV and 1332 keV gamma rays – a pair of high-aspect-ratio pencil beam collimators, and an inorganic scintillator detector. Here two acceleration methods are proposed to rapidly model a transmission type gamma-ray tomography system. The first, a variance reduction technique, is based on performing Monte Carlo simulations with a monodirectionally-biased source, sampled from a characteristic sub-volume of the full source volume. The second acceleration method is based on the deterministic calculations using the Beer–Lambert law and detector response characteristics. Comparison of simulations using acceleration approaches with analog simulations of the fully isotropic, full-volume equivalent, show that the Monte Carlo variance reduction technique gives quantitatively accurate predictions for large collimator aspect ratios while the deterministic calculations are semi-quantitative but converge close to the correct result as the collimator aspect ratio increases. As such, these techniques can be used to reduce the computational cost in generating simulated radiographs and tomographs by several orders of magnitude. Experimental validation efforts are currently underway and will be demonstrated in future work.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

WELDSMART: A vision-based expert system for quality control

This work was aimed at exploring means for utilizing computer technology in quality inspection and evaluation. Inspection of metallic welds was selected as the main application for this development and primary emphasis was placed on visual inspection, as opposed to other inspection methods, such as radiographic techniques. Emphasis was placed on methodologies with the potential for use in real-time quality control systems. Because quality evaluation is somewhat subjective, despite various efforts to classify discontinuities and standardize inspection methods, the task of using a computer for both inspection and evaluation was not trivial. The work started out with a review of the various inspection techniques that are used for quality control in welding. Among other observations from this review was the finding that most weld defects result in abnormalities that may be seen by visual inspection. This supports the approach of emphasizing visual inspection for this work. Quality control consists of two phases: (1) identification of weld discontinuities (some of which may be severe enough to be classified as defects), and (2) assessment or evaluation of the weld based on the observed discontinuities. Usually the latter phase results in a pass/fail judgement for the inspected piece. It is the conclusion of this work that the first of the above tasks, identification of discontinuities, is the most challenging one. It calls for sophisticated image processing and image analysis techniques, and frequently ad hoc methods have to be developed to identify specific features in the weld image. The difficulty of this task is generally not due to limited computing power. In most cases it was found that a modest personal computer or workstation could carry out most computations in a reasonably short time period. Rather, the algorithms and methods necessary for identifying weld discontinuities were in some cases limited. The fact that specific techniques were finally developed and successfully demosntrated to work illustrates that the general approach taken here appears to be promising for commercial development of computerized quality inspection systems. Inspection based on these techniques may be used to supplement or substitute more elaborate inspection methods, such as x-ray inspections.

Andersen, Kristinn↗

Domain Shift Analysis in Chest Radiographs Classification in a Veterans Healthcare Administration Population

This study aims to assess the impact of domain shift on chest X-ray classification accuracy and to analyze the influence of ground truth label quality and demographic factors such as age group, sex, and study year. We used a DenseNet121 model pre-trained MIMIC-CXR dataset for deep learning-based multi-label classification using ground truth labels from radiology reports extracted using the CheXpert and CheXbert Labeler. We compared the performance of the 14 chest X-ray labels on the MIMIC-CXR and Veterans Healthcare Administration chest X-ray dataset (VA-CXR). The validation of ground truth and the assessment of multi-label classification performance across various NLP extraction tools revealed that the VA-CXR dataset exhibited lower disagreement rates than the MIMIC-CXR datasets. Additionally, there were notable differences in AUC scores between models utilizing CheXpert and CheXbert. When evaluating multi-label classification performance across different datasets, minimal domain shift was observed in the unseen VA dataset, except for the label “Enlarged Cardiomediastinum.” The subgroup with the most significant variations in multi-label classification performance was study year. These findings underscore the importance of considering domain shift in chest X-ray classification tasks, paying particular attention to the temporality of the exam. Our study reveals the significant impact of domain shift and demographic factors on chest X-ray classification, emphasizing the need for improved transfer learning and robust model development. Addressing these challenges is crucial for advancing medical imaging research and improving patient care.

chest X-ray image classification↗

Harmonic Generation and Inverse Cascade in the z-Pinch Driven, Preseeded Multimode, Magneto-Rayleigh-Taylor Instability

We report the magneto-Rayleigh-Taylor instability (MRTI) plays an essential role in astrophysical systems and in magneto-inertial fusion, where it is known to be an important degradation mechanism of confinement and target performance. In this Letter, we show for the first time experimental evidence of mode mixing and the onset of an inverse-cascade process resulting from the nonlinear coupling of two discrete preseeded axial modes (400- and 550 - μm wavelengths) on an Al liner that is magnetically imploded using the 20-MA, 100-ns rise-time Z Machine at Sandia National Laboratories. Four radiographs captured the temporal evolution of the MRTI. We introduce a novel unfold technique to analyze the experimental radiographs and compare the results to simulations and to a weakly nonlinear model. We find good quantitative agreement with simulations using the radiation magnetohydrodynamics code hydra. Spectral analysis of the MRTI time evolution obtained from the simulations shows evidence of harmonic generation, mode coupling, and the onset of an inverse-cascade process. The experiments provide a benchmark for future work on the MRTI and motivate the development of new analytical theories to better understand this instability.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Bond Line Thickness Estimation in Composite Structures Using Multiple Inspection Techniques

Imaging and other nondestructive evaluation techniques are commonly used for material characterization and defect recognition in safety critical aerospace applications, with data fusion providing the framework for uncertainty quantification in these contexts. Most commonly, forward physics-based modeling predicts the response conditioned on material properties and defect assumptions, and probabilistic methods are used to infer the hidden state of subject of the inspection from a combination of prior information, likelihoods, and inspection data. In this paper Bayesian methods are used to estimate bond thickness in lap joints comprised of aluminum adherends using a combination of infrared thermography, digital radiography, and ultrasound. The accuracy of the fused estimates are validated against data generated from synthetic specimens, and by comparison against high resolution X-ray computed tomography inspections of built specimens.

thermal nondestructive evaluation↗

Direct observation of C 3 S particle dissolution using fast nano X-ray computed tomography

Tricalcium silicate (C 3 S) occupies 50 % to 70 % of ordinary portland cement (OPC) by mass and it is an important component affecting the hydration of OPC [1], [2], [3], [4], [5], [6], [7]. Generally, the hydration of C 3 S is described by two processes: the dissolution of C 3 S particles and the precipitation of hydration products. While it is understood that the dissolution rates of C 3 S vary with time, more precise measurements are needed to understand this process. Many mechanisms have been proposed to explain the time-evolving dissolution rates of C 3 S [2]. The metastable barrier hypothesis suggests that a thin metastable layer of hydrates forms around the C 3 S particle surface and prohibits the access of grains to the aqueous solution [8], [9], [10], [11], [12]. The slow dissolution step hypothesis suggests that the increased ion concentration from the initial reaction delays the C 3 S dissolution [2], [13], [14], [15], [16], [17]. More recent publications suggest that C 3 S may react differently depending on the existence of crystallographic defects [18], [19], [20]. Etch pits are thought to open on the particle surface during the initial reaction and this contributes to the C 3 S dissolution [21], [22]. As hydrates precipitate and cover these highly reactive surfaces, hydration slows down and the induction period starts [18], [23], [24], [25], [26]. Many experiments have been conducted to test the aforementioned mechanisms. Some hydration studies utilize bulk measurements, such as isothermal calorimetry [27], [28], [29], pore solution analysis [30], quasi-elastic neutron scattering [31], and nuclear magnetic resonance spectroscopy [32], [33]. One limitation of these measurements is that they do not provide direct and detailed information on the individual C 3 S particles. Some other studies utilize imaging techniques, such as scanning electron microscopy (SEM) [34], [35], [36] and transmission electron microscopy (TEM) [37]. However, SEM/TEM cannot track the evolution of individual particles throughout hydration [34], [35], [38], [39], [40] and they do not give insights into the microstructure of materials before hydration [34], [35], [39]. This makes it challenging to draw strong conclusions from only SEM or TEM observations. Synchrotron X-ray tomography techniques have been used more broadly in recent years to study cement hydration. They are not only non-destructive but also able to image a sample in full 3D with resolutions that can reach from micron to nanoscale. Nano computed tomography (nCT) is one technique that has been applied to study cement hydration at the nanoscale [26], [41]. A typical nCT can reach a pixel size from 15 to 65 nm, providing enough detail for observing features <1 μm. However, nCT often takes >0.5 h to finish one scan. This makes the application of this technique on continuous scans for in-situ observations challenging. Fast X-ray computerized tomography (fCT) is another technique that has shown success in studying the time-evolving cement microstructures [20], [42], [43], [44], [45], [46], [47], [48], [49]. Due to the high flux of the X-ray beam from the synchrotron ring, fCT allows a scan to be captured within 1 min at a pixel size of 1 μm. This allows a paste sample to be continuously scanned during the hydration process. However, the micron-sized resolutions limit does not provide detailed insights for particles <5 μm [20], [49]. Fortunately, the combination of nCT and fCT has allowed the development of fast nano X-ray computed tomography (fnCT). fnCT can capture a 3D data set in <2 min at a pixel size of 50 nm. This makes this procedure an exciting method to evaluate hydrating pastes. fnCT collects multiple X-ray radiographs at various rotation angles and generates a 3D model of the scanned sample, which is also referred to as a 3D tomography [50], [51]. In one tomography, the X-ray absorptions of different components (e.g., C 3 S and hydrates) differ as functions of density and chemistry [52], [53]. These X-ray absorption contrasts can be used to extract detailed information about the 3D microstructure [26], [54], [55]. In this paper, fnCT is used to collect time-lapse tomographs of hydrating C 3 S paste from 18 min after mixing to 7 h of hydration. The bulk measurements of anhydrous C 3 S, as well as the microstructural changes of individual C 3 S particles, are directly observed, quantified, and discussed. The dissolution behavior of C 3 S particles at various size scales is systematically analyzed and compared. This work aims to find the relationship between the size of C 3 S particle sizes and their dissolution rates. This provides significant insights into the early-age hydration of C 3 S on length and time scales not previously possible. Because of the magnitude of the data and the substantial amount of observations, this work will solely focus on the change in the anhydrous particles. Changes in the hydration products will be reported in future work.

42 ENGINEERING↗

High Intensity Gamma-Ray Source(HIγS) Radiographic Experiments

High Intensity Gamma-ray Source (HIGS) is a Free-Electron Laser (FEL) based Compton back-scattering γ-ray source. The HIGS facility is located on the campus of Duke University and operated by Triangle Universities Nuclear Laboratory (TUNL).

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Bond Line Thickness Estimation in Composite Structures Using Multiple Inspection Techniques

Imaging and other nondestructive evaluation techniques are commonly used for material characterization and defect recognition in safety critical aerospace applications, with data fusion providing the framework for uncertainty quantification in these contexts. Most commonly, forward physics-based modeling predicts the response conditioned on material properties and defect assumptions, and probabilistic methods are used to infer the hidden state of the subject of the inspection from a combination of prior information, likelihoods, and inspection data. In this paper Bayesian methods are used to estimate bond thickness in lap joints comprised of aluminum adherends using a combination of infrared thermography and ultrasound. The concept of the conflation of probability distributions is applied to combine the posterior distributions derived from thermography and ultrasound and the quality of the fused estimates are compared against the individual estimates against synthetic data that was created to mimic the inspection of a lap joint comprised of aluminum adherends.

thermal nondestructive evaluation↗

Enabling end-to-end secure federated learning in biomedical research on heterogeneous computing environments with APPFLx

Facilitating large-scale, cross-institutional collaboration in biomedical machine learning (ML) projects requires a trustworthy and resilient federated learning (FL) environment to ensure that sensitive information such as protected health information is kept confidential. Specifically designed for this purpose, this work introduces APPFLx - a low-code, easy-to-use FL framework that enables easy setup, configuration, and running of FL experiments. APPFLx removes administrative boundaries of research organizations and healthcare systems while providing secure end-to-end communication, privacy-preserving functionality, and identity management. Furthermore, it is completely agnostic to the underlying computational infrastructure of participating clients, allowing an instantaneous deployment of this framework into existing computing infrastructures. Experimentally, the utility of APPFLx is demonstrated in two case studies: (1) predicting participant age from electrocardiogram (ECG) waveforms, and (2) detecting COVID-19 disease from chest radiographs. Here, ML models were securely trained across heterogeneous computing resources, including a combination of on-premise high-performance computing and cloud computing facilities. By securely unlocking data from multiple sources for training without directly sharing it, these FL models enhance generalizability and performance compared to centralized training models while ensuring data remains protected. In conclusion, APPFLx demonstrated itself as an easy-to-use framework for accelerating biomedical studies across organizations and healthcare systems on large datasets while maintaining the protection of private medical data.

Biomedical Research↗