Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “radioactive air”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Development of electrostatic precipitator (ESP) technology to remove elemental mercury vapor, HG(0)

The presence of mercury vapor or other forms of mercury presents issues with worker safety, decommissioning facilities, and environmental impacts. As such, it is desired to develop a strategy to either remove or reduce mercury levels in Oak Ridge’s Y-12 Complex facilities. A testing methodology was developed to evaluate electrostatic precipitator technology for removal of mercury vapor. This methodology involved supplying mercury vapor-containing air to the ESP device by flowing air through a column containing alternating layers of sand and liquid mercury droplets. Initial attempts at quantifying the efficacy of the ESP device in removing mercury vapor were plagued with difficulties in controlling the flow of mercury into the ESP device due to poor performance of the generator column and the contamination of these experiments with mercury from an unknown source. These issues were resolved by creating a new generator column with slower air velocity and higher surface area of liquid mercury, along with moving the air intake for the ESP device to outside of the chemical hood in which testing took place. This resulted in a steady, quantified flow of mercury vapor from the generator column and no observation of unintended mercury sources. A final test of the ESP device under these controlled conditions showed that for a certain amount of time (on the order of 20-30 minutes) mercury concentrations were reduced by approximately 33 - 67% of the inlet concentration. However, episodic releases or pulses of mercury observed only at the outlet indicated that the mercury accumulated in the ESP device is periodically expelled. As a result, it was not deemed to be an efficient strategy for the removal of elemental mercury vapor.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Deliquescence of Eutectic LiCl-KCl Diluted with NaCl for Interim Waste Salt Storage

Molten eutectic LiCl-KCl salt is a widely used electrolyte for electrorefining uranium from spent nuclear fuel. Due to the hygroscopic nature of this salt, such operations must be performed under controlled atmospheric conditions, and waste salts require careful storage to avoid deliquescence and corrosion of container materials. This study investigated a potential processing path for reducing the degree of deliquescence through dilution to varying extents with NaCl. Here, the hydration behavior of LiCl-KCl salts diluted with NaCl was evaluated in terms of mass gain due to water absorption, degree of deliquescence (including first appearances of standing water), and evidence of corrosion to stainless steel containers in a humid air environment (40°C, 20% relative humidity). In this humid air environment, pure eutectic LiCl-KCl exhibited a 50 mass % increase due to water absorption and showed evidence of standing water after 24 h. Waste salt diluted with NaCl required loadings of 89 mass % NaCl in order to prevent deliquescence and exhibited a 3 mass % increase due to water absorption. After periodic observation for 48 h, standing water was observed near all ingots with the exception of the 89 mass % NaCl samples. Dilution with 89% NaCl was also found to reduce evidence of corrosion when stored in stainless steel crucibles. While dilution with NaCl greatly decreases steady-state hydration, the storage volume is increased ~10× through this procedure.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Project 57 Air Monitoring Report: (Jan 1 - Dec 31 2018)

During the late 1950s, the Atomic Energy Commission (AEC) (now the U.S. Department of Energy [DOE]) conducted a series of safety experiments to determine if a nuclear device subjected to a large conventional explosives detonation would result in a nuclear yield. The AEC obtained temporary use of a large portion of western Emigrant Valley from the U.S. Department of Defense (DOD) for one of these experiments: Project 57. Following the Project 57 safety experiment, the AEC fenced the contaminated area and returned control of the surrounding land to the DOD. Emigrant Valley is part of the Nevada Test and Training Range (NTTR). For safety and security reasons, access to the NTTR is controlled using both physical (i.e., fences) and administrative (e.g., signs and postings) controls. Therefore, the public cannot access the Project 57 site and there are no known human receptors that routinely access the site. Project 57 was detonated on April 24, 1957, in Emigrant Valley approximately 13 mi (21 km) northeast of the north end of Yucca Flat. This test was undertaken to develop: (1) a means of estimating immediate distribution and long-term redistribution of plutonium dispersed during a nonnuclear detonation; (2) biomedical evaluation techniques for use in likely plutonium-laden environments; (3) methods of decontaminating ground areas, pavements, and building materials; and (4) alpha survey instruments and field monitoring procedures to promptly estimate contaminant deposition. Although the test did not result in the fission of nuclear materials, it did disseminate plutonium across the ground surface. Various radiological surveys have been performed in the area since Project 57 was conducted. The AEC delineated the area containing radioactive material based on radioactivity surveys performed shortly after the test was conducted. A designated Contamination Area (CA), marked by a fence, was established later. The distribution of americium-241 (Am-241) in the area was determined again in a 1997 flyover, which showed Am-241 ranging from as much as 70,000 counts per second (cps) at ground zero to background (<70 cps). This survey also documented Am-241 radioactivity on the ground surface beyond the east side CA fence at levels of up to 150 cps. In 2007, the DOE expanded the CA by posting “Contamination Area” signs 200 ft to 400 ft (60 m to 120 m) beyond the original fence, which formed a new CA boundary.

54 ENVIRONMENTAL SCIENCES↗

Ascorbic Acid Stability and pH Testing to Support RWM-018 Pilot Scale Wellhead Treatment System Feasibility Determination

A multitude of groundwater remediation techniques for chlorinated volatile organic compounds (cVOCs) have been conducted at the A/M-Areas of the Savannah River Site (SRS). Historical in-situ chemical oxidation (ISCO) injections of potassium permanganate and sodium persulfate conducted in 2018 and 2020, have left residual oxidant concentrations in the A/M-Area groundwater system. ISCO events targeted dense non-aqueous phase liquids (DNAPLs) through the injection of strong oxidants within plume zones upgradient of current groundwater recovery wells RWM-008 and RWM-018. These residual oxidants could significantly impede the operation of the mercury removal system needed to meet National Pollutant Discharge Elimination System (NPDES) permit requirements for the ongoing pump-and-treat system that hydraulically controls potions of the A/M-Area plume. Effluent treated groundwater from this system is discharged to surface water at the receiving outfall of the M-1 Air Stripper. To prevent interference of the M-1 Air Stripper system by residual oxidants, groundwater recovery has been ceased at well RWM-018. Modeling of oxidant transport in A/M-Area from ISCO estimated that the potential oxidant load contributed by RWM-018 could be as high as 120 mg/L. It is also possible that oxidants may be contributed via pumping at well RWM-008 in the near future as residual oxidants within the aquifer migrate toward its zone of influence. Savannah River National Laboratory (SRNL) has conducted research to investigate potential pre-treatment chemicals to neutralize these residual oxidants, before reaching the M-1 Air Stripper, to allow for resumed groundwater recovery at RWM-018 and continued pumping at RWM-008. Deployment of ascorbic acid for neutralization of residual oxidants at RWM-018 (and possibly RWM-008) is recommended based on results from previous reductant testing (SRNL, 2021). For a maximum estimated oxidant load at RWM-0018, a well-head treatment system would need to dose about 400 gallons of ascorbic acid each month to ensure complete neutralization. A second system with additional reagent should also be considered for deployment at RWM-008.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Self-welding of Inconel 617 under high-pressure-high-temperature conditions for nuclear reactors

In response to continuously declining availability of fossil fuels, nuclear power has become an important alternative source of power generation. Growing application of nuclear power has relieved the shortage of electricity. However, it is also accompanied with new drawbacks, such as radioactive waste, and potential catastrophic consequences in case of major accidents. For nuclear power plants, severe accidents mostly originate from the reactor, making the reliability of the reactor of paramount importance to the overall safety of a nuclear power plant. Massive heat generation through nuclear fission/fusion and heat exchange render the whole reactor operating at extremely high temperatures (i.e., 900–1000 °C), which, in conjunction with large load from subsystems/ components made of special heavy alloys, renders the reactor under the risk of self-welding, a phenomenon that could lead to strong bonding between components and paralyze the operability of the nuclear reactor. This paper investigates the self-welding behavior of Inconel 617, a primary candidate nickel alloy for key components of the next generation gas cooled nuclear plant, inside a controlled atmospheric furnace with preset static load, simulating the high-pressure high-temperature conditions inside nuclear reactors. Therefore, test results show that Inconel 617 experiences self-welding through common oxide zone at the interface, and it has remarkable bonding strength, requiring 4114 N (57.15 MPa) and 4338 N (60.25 MPa) to break apart a mated sample pair, under an apparent contact pressure of 0.341 MPa after 50-h aging, in helium and air atmospheres, respectively. The higher oxygen presence in air results in slightly stronger oxide bond at the interface, compared to helium, and the bond strength increases with dwell time.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Comparison of Extended and Accelerated VOG Tests

The reprocessing of used nuclear fuel would release volatile radionuclides into the off-gas streams of a processing plant, including ¹²⁹I. The dissolver off-gas and more dilute vessel off-gas streams (VOG) must both be targeted when mitigating ¹²⁹I environmental release because each contains some amount of iodine. Iodine-129 will likely be found as elemental iodine (I₂) and methyl iodide (CH₃I) in these off-gas streams. Reduced silver-exchanged mordenite (AgZ or Ag⁰Z) has been investigated as a potential sorbent for iodine abatement and is studied here under prototypic VOG conditions. Because of the relatively low iodine abundance and high flow rates of the VOG, total iodine concentrations are expected to be in the parts per billion range. Thus, VOG experiments need to run for extended durations at low concentrations to reach sorbent saturation. Because the sorbent will be exposed to oxidizing gas streams for extended periods of time, aging effects and sorbent degradation need to be considered when designing a sorbent-based abatement system. Three sets of experiments were performed with the aim of determining how the adsorption of iodine by AgZ is affected by differing test durations and gas compositions. The first tested the capacity of sorbent aged for 8 months under a humid air stream. The second tested differences in sorbent capacity and mass transfer zone (MTZ) length during high-concentration (1200 ppb v ) CH₃I loading in a humid nitrogen gas (N₂) stream and a humid air gas stream over 28 days. The third tested sorbent capacity and MTZ length during low concentration (< 200 ppb v ) CH₃I and I₂ loading in a humid air stream over 9 months. The results of these tests suggest that AgZ capacity drops by ~50% after 1 month of aging, by ~60% after 2 months of aging, and then does not continue to decrease significantly at up to 8 months of aging. One-month aging tests that compared N₂ and air as the gas stream diluent resulted in similar maximum loading capacities and overall loading curves, indicating that the effects of aging cannot be mitigated by avoiding air as the balance gas. The 9-month extended VOG tests did not result in clear sorbent saturation at the inlet, but it can be inferred using an assumption of a maximum capacity of 45 mg I/g AgZ. Applying this assumption, then the MTZ of CH₃I is 12.8 cm, and the MTZ of I₂ is 12.4 cm. These results are similar to previous tests. Comparisons to tests completed at Idaho National Laboratory suggest that the CH₃I MTZ may be dependent on concentration. Future work should re-evaluate the design of the VOG iodine capture system with this updated data and should seek to understand fundamental characteristics of CH₃I adsorption by AgZ, such as the effect of concentration, gas velocity, and gas composition.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

SR19021 Tritium Aging of Regenerated LANA.75 (Final Project Report)

The Savannah River Tritium Enterprise (SRTE) has used the metal hydride LaNi 4.25 Al 0.75 (LANA.75) in the Tritium Facilities for over two decades. LANA.75 beds store significant quantities of tritium but have a limited service life due to the radiolytic decay of tritium to He-3 within the metal matrix. It has been shown that heating tritium-aged LANA.75 under vacuum can reverse tritium aging effects, eliminating the heel of trapped hydrogen, and restoring the reversible capacity. Additional investigation is needed to ensure there are no unexpected changes to the hydride before this restoration technique is employed in full scale beds in the Tritium Facilities. This project was to be comprised of three distinct scopes: obtain tritium aging data on the sample regenerated in 2018, regenerate a tritium-aged sample at 600 °C, and perform thermal stability testing on a non-tritiated sample. Isotherms were collected on the previously regenerated sample after approximately two years of tritium aging. Isotherms were collected at 80, 100, and 120 °C. As expected, there was a decrease in the plateau pressure, an increase in plateau slope, and a portion of the “heel” of tritium trapped in the metal had been reestablished. Unexpectedly, it appeared that the plateau had shortened at the higher tritium to metal ratios as well. This is typically seen in older samples. The second scope, to regenerate a second tritium-aged LANA.75 sample, was not completed. A Task Technical and Quality Assurance Plan was written and approved, a high temperature test cell was fabricated, several pre-job briefs were held, and the hydride sample was passivated with air. Despite these successes, the hydride sample was not recovered from the legacy test cell. The third scope was to perform thermal stability testing on a “cold” LANA.75 sample. A non-tritiated sample of LANA.75 was held at 750 °C under vacuum for 200 hours to simulate exposure to multiple regeneration evolutions. Hydride isotherm performance, chemical composition, crystallinity, particle size, and morphology are compared between the pre- and post-regeneration samples. No significant changes were observed in composition, crystallinity, or particle size. Comparison of before and after isotherms showed that performance improved rather than deteriorated during the evolution. Scanning Electron Microscopy (SEM) analysis showed small growths on the particle surface after exposure to regeneration conditions. Additional testing will be required to determine the cause of these growths.

07 ISOTOPE AND RADIATION SOURCES↗

Tests of a High Temperature Sample Conditioner for the Waste Treatment Plant LV-S2, LV S3, HV S3A and HV-S3B Exhaust Systems

Tests were performed to evaluate a sample conditioning unit for stack monitoring at Hanford Tank Waste Treatment and Immobilization Plant (WTP) exhaust stacks with elevated air temperatures. The LV-S2, LV-S3, HV-S3A and HV-S3B exhaust stacks are expected to have elevated air temperature and dew point. At these emission points, exhaust temperatures are too high to deliver the air sample directly to the required stack monitoring equipment. As a result, a sample conditioning system is considered to cool and dry the air prior to its delivery to the stack monitoring system. The method proposed for the sample conditioning is a dilution system that will introduce cooler, dry air to the air sample stream. This method of sample conditioning is meant to reduce the sample temperature while avoiding condensation of moisture in the sample stream. An additional constraint is that the ANSI/HPS N13.1-1999 standard states that at least 50% of the 10 µm aerodynamic diameter (AD) particles present in the stack free stream must be delivered to the sample collector. In other words, depositional loss of particles should be limited to 50% in the sampling, transport, and conditioning systems. Based on estimates of particle penetration through the LV-S3 sampling system, the diluter should perform with about 80% penetration or better to ensure that the total sampling system passes the 50% or greater penetration criterion.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

2021 Annual Site Environmental Report

This report provides the U.S. Department of Energy (DOE) and the public with information on the level of radioactive and non-radioactive pollutants (if any) that are added to the environment as a result of Princeton Plasma Physics Laboratory’s (PPPL) operations. The results of PPPL’s 2021 environmental surveillance and monitoring program are presented and discussed. The report also summarizes environmental initiatives, assessments, and community involvement programs that were undertaken in 2021. PPPL’s on-site operations were significantly curtailed in 2021 due to the global coronavirus pandemic. PPPL has engaged in fusion energy research since 1951. The Laboratory’s mission is to develop the scientific knowledge and advanced engineering to enable fusion to power the U.S. and the world, and to developing the understanding of plasmas from the nano- to the astrophysical scale. PPPL’s primary experiment, the National Spherical Torus Experiment-Upgrade (NSTX-U) is a collaboration among national laboratories, universities, and national and international research institutions and is a major element in the US Fusion Energy Sciences Program. Its design tests the physics principles of spherical torus (ST) plasmas, playing an important role in the development of smaller, more economical fusion reactors. Due to previous operational issues, NSTX-U did not operate in 2021. PPPL is engaged in a project to replace key NSTX-U components and systems to enable operation of this international fusion user facility. In 2021, PPPL’s radiological environmental monitoring program measured tritium in the air at the NSTX-U Stack and at onsite sampling stations. Using highly sensitive air monitors, PPPL is capable of detecting small changes in the ambient levels of tritium. The operation of an in-stack monitor located on D-site is used to demonstrate compliance with the National Emission Standard for Hazardous Air Pollutants (NESHAPs) regulations. Also included in PPPL’s radiological environmental monitoring program, are water monitoring – ground, surface, and waste waters. PPPL’s radiological monitoring program characterized the background levels of tritium in the environment and those data are presented in this report. Ground water monitoring continued under New Jersey Department of Environmental Protection’s (NJDEP) Site Remediation Program regulations. PPPL monitored for non-radiological contaminants, mainly volatile organic compounds (components of common degreasing solvents). In 2021, PPPL complied with permit limits for surface and sanitary discharges. PPPL was honored with awards for EPEAT-certified electronics purchasing and use of peracetic acid as an alternative water treatment chemical in its non-potable process water systems an NJDEP recycling award.

54 ENVIRONMENTAL SCIENCES↗

Prediction for Pressure Differential Across HEPA Filter Media Based on Media Characteristics and Particle Size Distribution

A new method for predicting the pressure drop across High Efficiency Particulate Air (HEPA) filter media is proposed based upon mass deposited onto the filter and known physical characteristics of the filter media. Detailed are the methods used in conjunction with current filter loading models to predict the pressure drop, as well as tests conducted to validate the methods. The benefit of a prediction model for practical use lies in the manufacturing and service life of nuclear grade HEPA filters. HEPA filters for use in nuclear facilities have a prescribed expiration date and a maximum allowable operating pressure drop. Therefore, the ability to predict the pressure drop across a filter and relate it to an expected length of service time can enable a reduction in wasted filters. This will allow for more informed decisions to be made based upon the dictated life cycle of the filters. Also, understanding and predicting how the pressure drop of HEPA filter media behaves as a function of physical characteristics and loaded mass can assist in future design and manufacturing of filter media. Currently, most existing pressure drop models are either computationally based or analytical methods relying on data gathered during tests. Neither are practical for prediction; the computational methods are difficult to implement, and the current analytical methods are more useful as tools for analysis. The current analytical model developed by Bergman et al. is based upon the pressure drop from each media fiber and modeling the deposited particles as newly formed fibers. Using Bergman's model and the media properties, air properties, and known aerosol particle size distribution, a pressure drop curve as a function of loaded mass can be created. This curve implies initial loading in the depth of the filter media with a transition to pure surface loading on the filter face, and a sensitivity to an evolving particle size distribution as mass continues to load onto the filter. To implement the predictive model, knowledge of the mean filter fiber diameter and porosity of the filter media is required. Traditionally, the mean fiber diameter is calculated as an effective diameter from prior media testing, however, in this study a Scanning Electron Microscope (SEM) technique is used to acquire this variable. Validation of the predictive model is provided by flat sheet media tests under a controlled environment with a measured particle size distribution of the challenge aerosol and shows reasonable preliminary agreement.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Princeton Plasma Physics Laboratory Annual Site Environmental Report for Calendar Year 2024

This report provides the US Department of Energy (DOE) and the public with information on the level of radioactive and non-radioactive pollutants (if any) that are added to the environment as a result of Princeton Plasma Physics Laboratory’s (PPPL) operations. This report fulfills the annual public reporting requirements of DOE Order 231.1B. The results of PPPL’s 2024 environmental surveillance and monitoring program are presented and discussed. The report also summarizes environmental initiatives, assessments, and community involvement programs that were undertaken in 2024. PPPL has engaged in fusion energy research since 1951 and at its current locations since 1958. The Laboratory’s mission is to develop the scientific knowledge and advanced engineering to enable fusion to power the US and the world, and to develop the understanding of plasmas from the nano- to the astrophysical scale. PPPL’s primary experiment, the National Spherical Torus Experiment-Upgrade (NSTX-U) is a collaboration among national laboratories, universities, and national and international research institutions and is a major element in the US Fusion Energy Sciences Program. Its design tests the physics principles of spherical torus (ST) plasmas, playing an important role in the development of smaller, more economical fusion reactors. Due to previous operational issues, NSTX-U did not operate in 2024. PPPL is engaged in a project to replace key NSTX-U components and systems to enable the operation of this international magnetic fusion user facility. In 2024, PPPL’s radiological environmental monitoring program measured tritium in the air at onsite sampling stations. Using highly sensitive air monitors, PPPL is capable of detecting small changes in the ambient levels of tritium. The operation of monitors located on D-site is used to demonstrate compliance with the National Emission Standard for Hazardous Air Pollutants (NESHAPs) regulations. Also included in PPPL’s radiological environmental monitoring program, are water monitoring – ground, surface, and waste waters. PPPL’s radiological monitoring program characterized the background levels of tritium in the environment and those data are presented in this report. Ground water monitoring continued under New Jersey Department of Environmental Protection’s (NJDEP) Site Remediation Program regulations. PPPL monitored for nonradiological contaminants, mainly volatile organic compounds (components of common degreasing solvents). In 2024, PPPL complied with permit limits for surface water and sanitary wastewater discharges. PPPL was honored with an award for EPEAT-certified electronics purchasing from the Global Electronics Council on July 25, 2024.

54 ENVIRONMENTAL SCIENCES↗

Direct Extraction of Uranium-Lanthanide Oxides in Tributyl Phosphate

Abstract Direct extraction of used nuclear fuel (UNF) in an organic solution could be more efficient than the previous practice with aqueous solutions. However, the UNF would need to be treated via voloxidiation before being processed using solvent extraction. The voloxidation process can form oxide and/or nitrate compounds. This work investigated the dissolution of uranium/lanthanide oxides in 30 vol % TBP diluted in dodecane (pre-equilibrated with 4 M nitric acid) in a glass reactor with air sparging to ascertain the uranium/lanthanide oxide dissolution behavior prior to scaling the process. The uranium/lanthanide oxides were prepared by co-precipitating uranium/lanthanide nitrates with hydroxide and then calcined to form a mixed oxide. While the relative concentrations of the lanthanides are not representative of used nuclear fuel, the neodymium and erbium allowed ease of tracking dissolution with visible spectroscopy. Cerium was used as a surrogate for plutonium. The dissolution rate of the oxides was similar but incomplete. A miniscule amount of cerium, as cerium oxide, took several months to slowly dissolve; however, when co-precipitated with uranium and other lanthanides, a significant amount of cerium dissolved readily.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Capture of Iodine from Nuclear-Fuel-Reprocessing Off-Gas: Influence of Aging on a Reduced Silver Mordenite Adsorbent after Exposure to NO/NO 2

Iodine radioisotopes released during nuclear fuel reprocessing must be removed from the off-gas stream before discharge. One promising material for iodine capture is reduced silver mordenite (Ag 0 Z). Nevertheless, the adsorbent’s capacity will degrade, or age, over time when the material is exposed to other off-gas constituents. Though the overall impact of aging is known, the underlying physical and chemical processes are not. To examine these processes, Ag 0 Z samples were prepared and aged in 2% NO 2 in dry air and in 1% NO in N 2 gas streams at 150 °C for up to six months. Aged samples were then characterized using scanning electron microscopy, X-ray diffraction, Raman spectroscopy, and X-ray absorption spectroscopy. These techniques show that aging involves two overarching processes: (i) oxidation of the silver nanoparticles present in Ag 0 Z and (ii) migration of oxidized silver into the mordenite’s inner network. Silver on the nanoparticle’s surface is oxidized through adsorption of O 2 , NO, and NO 2 . Additionally, Raman spectroscopy and X-ray absorption spectroscopy indicate that nitrates are the primary products of this adsorption. Most of these nitrates migrate into the interior of the mordenite and exchange at framework binding sites, returning silver to its unreduced state (AgZ). The remaining nitrates exist at a persistent concentration without aggregating into bulk-phase AgNO 3 . X-ray absorption spectroscopy results further indicate that iodine adsorption occurs on not just Ag 0 Z but also on AgZ and a portion of the nitrates in the system. AgZ adsorbs a sizable quantity of iodine early in the aging process, but its capacity drops rapidly over time. For well-aged samples, nitrates are responsible for up to 95% of mordenite’s iodine capacity. Overall, these results have enhanced our understanding of the aging process in silver mordenite and are expected to guide the development of superior adsorbents for the capture of radioactive iodine from reprocessing off-gas.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Determining Unabated Airborne Radionuclide Emissions Monitoring Requirements Using Inventory-Based Methods

Compliance with the airborne radionuclide emission monitoring requirements in the National Emission Standards for Hazardous Air Pollutants (NESHAP; Title 40 of the U.S. Code of Federal Regulations Part 61, Subpart H) and State requirements in Washington Administrative Code 246–247: Radiation Protection – Air Emissions and 173-480: Ambient Air Quality Standards and Emission Limits for Radionuclides were evaluated for Pacific Northwest National Laboratory (PNNL) operations. Additional guidance may be found in the U.S. Department of Energy Handbook, Environmental Radiological Effluent Monitoring and Environmental Surveillance. To meet regulatory requirements, reviews of planned or proposed projects and activities provide the basis for implementing necessary monitoring adjustments or for implementing changes to projects and activities in a timely manner. Potential unabated off-site doses were evaluated for emission locations managed by PNNL and licensed to the Department of Energy. These locations were at facilities in Richland, Washington (i.e., the Hanford Site and PNNL–Richland campus) and in Sequim, Washington, (PNNL–Sequim campus). This report describes the inventory-based methods and provides the results for the NESHAP assessment performed in January 2024 for calendar year ending 2023.

40 CFR 61 Subpart H↗

Amphiphilic Block Copolymers for Flocculation and Hydrophobization of Legacy Waste Suspensions in Flotation Driven Dewatering Operations - 20162

Flotation has been effectively demonstrated as a low footprint, high efficiency separation process when utilising simple anionic surface modifying agents such as sodium dodecyl sulphate (SDS). These agents increase hydrophobicity to remove suspended cationic surface charged particulates such as Mg(OH){sub 2} from waste suspensions similar to those at British nuclear fuel management sites- where corrosion processes have degraded fuel cladding. The technology is advantageous as it could effectively be retrofitted into existing waste management facilities at nuclear waste management sites such Sellafield and Hanford as the simplicity (no moving parts) and size of this technology coupled with low cost of construction could be rapidly deployed to aid in risk and hazard reduction decommissioning operations with minimum impact to secondary waste generation. Previously, sodium dodecyl sulphate has been deployed as a collector agent to increase the hydrophobicity of Mg(OH){sub 2} suspended particles, achieving a maximum particulate extraction percentage of 93%. To achieve further particulate extraction, flotation performance has been determined to be a function of the hydrodynamic limitations extracting fine material (>20 μm). Fine particulates have been shown in the minerals industry to have an inability to overcome slipstreams created from rising bubbles in flotation cells, likely due to the low mass and thus momentum of the colloidal material, preventing interaction between the hydrophobized particles and air-water interfaces (bubbles). To combat this mass transfer resistance poly(acrylic acid)-block-poly(n-butyl acrylate) amphiphilic diblock copolymers were synthesised via reversible addition-fragmentation chain-transfer (RAFT) polymerisation. The anticipated mode of action of these polymers involves the hydrophilic poly(acrylic acid) block polymer acting as a flocculation agent to increase the mass of the aggregates, and the hydrophobic poly(n-butyl acrylate) modifies the hydrophobicity of the resulting flocs. The concentration of this polymer (termed a macro-collector) was varied and the change in particle size distribution of the particulate suspension was analysed using static light scattering. The flotation performance was then characterised by several methods including percentage particulate recovery, volume reduction factor and residual bulk particulate concentration. This was then benchmarked against the traditional surfactant collector agent SDS. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Overview of 2017 Through 2018 Testing of Powered Air-Purifying Respirator (PAPR) Cartridge Performance on Multiple Hanford Tank Headspaces and Exhausters

Between 2017 and 2018, 10 powered air-purifying respirator (PAPR) cartridge tests were performed on headspace vapors from three Hanford tanks (BY-108, SX-101, and SX-104) and two Hanford Tank Farm exhausters (AP in 2018 and AX in 2017). All tests were conducted under static conditions absent waste-disturbing activities in the subject tanks or tank farms. Multipurpose high-efficiency PAPR cartridges, MSA-TL (TL1) (MSA Safety Inc., Pittsburgh, Pennsylvania) and 3M FR-57 (TL2) (3M Company, Maplewood, Minnesota), were tested on each of the five tanks or exhausters. Out of 61 1 Chemicals of Potential Concern (COPCs), only ammonia and 2,5-dimethylfuran exhibited breakthroughs with outlet concentrations that were greater than 10% of their Occupational Exposure Limits (OEL). For 2,5-dimethylfuran, elevated concentrations found in blank tube samples made the elevated outlet measurements for this COPC questionable.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Idaho National Laboratory’s Mobile Hot Cell Transportation: Engineering Solutions for Global Disused Sealed Radioactive Sources.

Title: Idaho National Laboratory’s Mobile Hot Cell Transportation: Engineering Solutions for Global Disused Sealed Radioactive Sources. Abstract: The Mobile Hot Cell (MHC), currently under development by Idaho National Laboratory (INL) for the Off-Site Source Recovery Project (OSRP), is designed to help international partners meet the unique challenges of end-of-life radioactive material management. The MHC will provide a critical resource for countries that require assistance securing and disposing of Disused Sealed Radioactive Sources (DSRS) and orphaned sources in challenging environments, allowing these sources to be secured against misuse and nefarious activities. The MHC is a rapidly deployable system for conditioning and preparing end-of-life radioactive sources for transportation or storage. It is designed to handle sources of up to 1,000 Ci Co-60 equivalent while maintaining full radiological and biological containment. It will be deployable within 48 hours of an alert, making it ideal for emergency situations. The MHC features an operational suite for control, support racks for electronics, pneumatics, and welding systems, and a modular robust steel structure providing radiological shielding and internal robotic support. This design allows configurations for multiple device types to be conditioned and the ability to safely manage routine issues such as leaking or damaged sources. The MHC has been designed with the transportation challenges of rapid deployment to difficult environments in mind. The system weighs approximately 150,000 pounds, with individual systems breaking down into pieces not exceeding 20,000 pounds. Components are to be transportable on standard 20ft ISO containers, with shielding shells on 20ft flat racks. It is estimated that a total of eight containers and flat racks will be required. The use of 20ft containers, as opposed to 40ft containers, minimizes the impact on less developed road infrastructures, enabling the MHC to be positioned in constrained environments such as hospital parking lots. The system’s modularity also allows for deployment using smaller equipment, such as a 10-ton boom truck or forklift, which is crucial given the potential logistical challenges in different countries. This transportation strategy, evaluated in collaboration with Utah State University, ensures the MHC can be deployed via ground, rail, sea, or air, addressing the primary concern of international transport logistics.

99 - GENERAL AND MISCELLANEOUS↗

Heat transfer enhancement due to cold cap motion from bubbling in a waste glass melter

In this study, a computational fluid dynamics (CFD) model was developed to model the motion of a solid cold cap in a waste glass melter. Forced convection bubblers at the base of the melter release air into the molten glass, which forms large bubbles that travel upwards to the cold cap and augment heat transfer from the glass to the cold cap. The CFD model employs the Navier- Stokes equations to solve for the fluctuating flowfield using a rigid body motion dynamic fluid body interaction module. This allows for movement of the floating body in response to the bubbling forces calculated at each time step. Further, the heat flux delivered to the cold cap by the convective bubbling is studied as a function of the bubbling rate. Results for the moving cold cap are compared with the computed heat flux trends for a stationary cold cap. The heat flux delivered to the cold cap from the glass is 25% higher for the case with the moving cold cap. The heat flux was found to be proportional to v0.6 as opposed to v0.9 (where v is the normalized bubbling rate) for the stationary cold cap.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗