Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “radiation detection systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Advanced X-ray emission spectrometers

Spectroscopy systems require a crystal having specific properties for analyzing a spectrum of a sample, which is typically performed for measuring the presence of one element at a time. A two-dimensional (2D) crystal mount for performing simultaneous spectroscopy measurements includes a crystal holder having multiple rows of crystal mounts. Each crystal mount is positioned and orientated to physically support a crystal at a fixed position and fixed orientation relative to an optical axis. A sample provides radiation to analyzer crystals disposed in the crystal mounts, and a detector may detect radiation reflected from the analyzer crystals, for performing multiple simultaneous spectroscopy measurements.

Sun, Chengjun↗

First principles optimization of plutonium electrorefining

Herein this work presents a means of controlling plutonium electrorefining at a maximum rate regardless of equipment setup through the derivation of power supply current and potential governing equations for normal and off-normal operations. The governing equations are demonstrated by electrorefining surrogate materials. A simple linear current sweeping method was used to determine the maximum electrorefining current for the surrogate system. This method can be used to develop autonomous process optimization, real-time online processing monitoring, and real-time process endpoint detection. Ultimately, this research provides the foundation to optimize the liquid metal electrorefining rate to decrease the time needed to the physical limit for the process.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Remote isotope detection and quantification using femtosecond filament-laser ablation molecular isotopic spectrometry

We demonstrate the detection and quantification of isotopes from solid samples remotely at a distance of 36 m. This was accomplished through the combination of femtosecond filaments and laser ablation molecular isotopic spectrometry (F 2 -LAMIS). Isotopically enriched graphite samples with varying 13 C concentration were used and the F 2 -LAMIS emission was measured remotely using a portable spectrometer system. A standardless quantification approach was used to determine the corresponding isotopic ratios. The use of F 2 -LAMIS for the detection and quantification of isotopes at atmospheric pressure without the use of calibration standards opens the possibility to implement this technology for remote sensing of isotopes in field applications

07 ISOTOPE AND RADIATION SOURCES↗

Thermal aging effects on crosslinked polyethylene cable insulation with decabromodiphenyl ether flame retardant alternative

Decabromodiphenyl ether (decaBDE) has been extensively used as a flame retardant in several applications, including nuclear electrical cable insulation. However, decaBDE has been identified as a persistent, bioaccumulative and toxic (PBT) substance, leading to regulatory scrutiny. The Environmental Protection Agency (EPA) published a regulation on January 6, 2021, aimed at phasing out the manufacturing, processing, and distribution of decaBDE. This rule set a compliance deadline of March 8, 2021, for the manufacture and processing of decaBDE, and an extended deadline of January 6, 2023, for specific applications including wire and cable insulation in nuclear power generation facilities. In response to such regulations, RSCC, a major supplier of safety-related electrical cables and associated products to the U.S. nuclear industry updated the formula of their crosslinked polyethylene (XLPE) insulation to replace the historically used decaBDE flame retardant with an acceptable alternative. This change from the previous decaBDE-containing XLPE prompted interest in comparative performance of the two material formulations, especially with respect to characteristics relevant to safety-related function such as thermal and radiation resistance. RSCC graciously provided samples of wire insulated with the decaBDE-containing XLPE formulation and corresponding wire insulated with XLPE of the new formulation, containing a decaBDE alternative. In this work we compare characteristics of the two formulations and a previously produced commercial version of the RSCC decaBDE-containing XLPE insulation subjected to thermal aging at 150 °C and 165 °C. The comparison was focused on mechanical durability, thermal stability in the oxidative environment, and chemical structures. Briefly, • Tensile elongation at break (EAB) results showed loss of mechanical elasticity with longer aging time, as expected. Aging time dependence of EAB did not differ between the decaBDE-containing and decaBDE-alternative samples. • Subtle differences between the two materials can be detected from Fourier-transform infrared spectroscopy (FTIR) absorbance spectra in the range below 1700 cm -1 , are assumed to be related to decomposition of flame retardant additives during thermal aging. • The oxidation induction time (OIT) data seemed to show that the unaged decaBDE-containing XLPE material is more thermally stable than the unaged decaBDE-alternative material, but the discrepancy in OIT decreased with aging time and the OIT values of the two materials became similar starting with the 4 th day of aging at 165 °C. This thermal aging investigation confirmed that the mechanical durability, a key property monitored for cable qualification, was not significantly affected by the modification of the formulation with a decaBDE alternative flame-retardant system in the investigated thermal aging conditions. Further studies on the same sets of materials exposed to thermal and gamma radiation aging would further inform comparison of the materials safety-related function.

36 MATERIALS SCIENCE↗

Method for calculating radon activity and radon rejection using a beta-gamma detector

Radon interferes with concentration measurements used by atmospheric radioxenon systems. We demonstrate a method to quantify the amount of radon that is present in the detectors, the impact of radon activity on the minimum-detectable-concentrations, and how to determine the needed radon rejection levels. An example calculation shows a radon rejection level of 10 5 is sufficient to limit impact on the detector sensitivity. We anticipate this method will give analysist a better understanding of radon present in their measurements and allow system designers to tailor their systems’ radon rejection better for its location.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Spectral Hardness of X- and Gamma-Ray Emissions From Lightning Stepped and Dart Leaders

During the 2022 New Mexico monsoon season, we deployed two X-ray scintillation detectors, coupled with a 180 MHz data acquisition system to detect X-rays from natural lightning at the Langmuir Lab mountain-top facility, located at 3.3 km above mean sea level. Data acquisition was triggered by an electric field antenna calibrated to pick up lightning within a few km of the X-ray detectors. We report the energies of over 240 individual photons, ranging between 13 keV and 3.8 MeV, as registered by the LaBr3(Ce) scintillation detector. These detections were associated with four lightning flashes. Particularly, four-stepped leaders and seven dart leaders produced energetic radiation. Importantly, the reported photon energies allowed us to confirm that the X-ray energy distribution of natural stepped and dart leaders follows a power-law distribution with an exponent ranging between 1.09 and 1.96, with stepped leaders having a harder spectrum. Characterization of the associated leaders and return strokes was done with four different electric field sensing antennas, which can measure a wide range of time scales, from the static storm field to the fast change associated with dart leaders.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Assessment of Acoustic Sensor Application to Structural Health Monitoring of Reactor Components

The objectives of SHM of advanced fission reactors include the following: (1) Maintain safe, reliable, and efficient operation of structures, systems, and components in accordance with design intent; (3) Reduce cost; (4) Improve the comprehensive life management of structures, systems, and components; and (5) Extend the operational life of a power system through retirement for cause. Advanced reactor designs currently being considered are expected to operate at higher temperatures than light water-cooled reactors and to support missions beyond baseload electricity generation. Methods to monitor and detect for these mechanisms will require structural health monitoring (SHM) techniques, with ultrasonic methods an ideal candidate given their widespread use for NDE. This document summarized the state of technology for ultrasonic technologies, as part of an assessment of technology gaps and needed research. The great majority of sensor development to date addresses elevated temperatures and radiation tolerance, and more work is needed in both areas. Little data exists regarding corrosion effects of advanced coolants on sensor materials and couplants. Of high importance is the need for ARDs and regulatory bodies to engage and define what level of SHM is needed for autonomous or semi-autonomous control of reactors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Low-energy effective quantum field theoretic description of excitations about soliton configurations

Solitons are the classical field configurations connecting two trivial vacua. These are also the solutions of classical field equations of motion with particle-like properties. Moreover, they are localized in space, having finite energy, and are stable against decay into radiation. The coherent state description of kink-solitons is discussed in the present article. Further, the relation between topological solitons and occupation numbers corresponding to low momentum excitations are also discussed coherently. The description of the low energy excitations about solitons in quantum field theory is the main theme of this article. Further, a few physical observables, namely some low order correlation functions, are computed up to certain integral forms. Furthermore, we have shown that it is possible to detect the presence of soliton-like classical configurations in many-particle systems from the nature of the one-point function and non-conservation of momentum feature of one-point, two-point and three-point functions in this low-energy effective field theory of these excitations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Multiaxis sensing system for detection of airborne molecules and radionuclides

Various technologies presented herein relate to a method and equipment for detecting both airborne radioisotope and molecular effluent gases. Multi-Axis Sensing can be conducted by utilizing a pressurized MOF sorbent, such as a scintillating Metal-Organic Frameworks (S-MOFs). These MOFs are crystalline nanoporous materials that have synthetic versatility that allow adjustment of pore size, chemical environment, and luminescence properties. A method for detecting an analyte in a fluid sample is provided that comprises: loading a sorbent with a sample fluid, wherein the sorbent comprises a MOF material; pressurizing the sample fluid to increase the fluid in the sorbent thereby making a pressurized sorbent; and detecting ionizing radiation or a chemical property of the analyte in the pressurized sorbent.

Allendorf, Mark D.↗

Performance characterization of 5×5×12 mm 3 virtual Frisch-grid TlBr detectors

Thallium bromide (TlBr) is a promising material for semiconductor gamma-ray detectors due to its high atomic number (Tl = 81, Br = 35), high density (7.56 g/cm 3 ), and relatively low melting point (460 °C). These properties give TlBr several competitive features, including high detection efficiency, good energy resolution, and lower fabrication costs, making it suitable for applications requiring compact, highly sensitive gamma-ray detection systems. Recent developments of TlBr detectors have progressed toward thicker crystals, up to 10–20 mm, configured as pixelated or virtual Frisch-grid (VFG) devices with volumes >1 cm 3 . Despite these advances, challenges remain in practical implementation, including material and fabrication issues that affect energy resolution, device stability, performance, and longevity. These challenges are similar to those faced by HgI 2 and lead-halide perovskite detectors. Here, this study presents results from characterizing over 100 position-sensitive 5×5×12 mm 3 virtual Frisch-grid detectors fabricated by Radiation Monitoring Devices Inc. For a prototype Radioisotope Identification Device (RIID). The work identified factors limiting the performance and longevity of TlBr detectors, including stochastic response variations that limit the energy resolution to 2–3 % (at 662 keV) for most devices, performance degradation associated with defect decoration, and contact delamination. Addressing these issues advances the use of TlBr and similar materials for reliable, high-resolution gamma-ray spectroscopy.

47 OTHER INSTRUMENTATION↗

An Ensemble Approach to Computationally Efficient Radiological Anomaly Detection and Isotope Identification

Radiological source search is a challenging task involving detection and identification of weak sources in a constantly changing radiological background. As of now, many radiological source detection algorithms have been proposed; however, their computational complexity, and hence reliance on power intensive processing units inhibit low-power applications of radiological source search systems. In this work, we introduce the anomaly filter (AF) algorithm; a computationally light, yet effective time-series source detection algorithm based on exponential weighted moving average (EWMA) and Poisson deviance statistics. Then, we demonstrate that the proposed algorithm can be used in ensemble with other more computationally intensive source detection and identification algorithms to achieve both increased detection performance and reduced power consumption. The proposed AF algorithm and the ensemble algorithms were thoroughly benchmarked against several existing source detection and identification algorithms. The results show that the AF algorithm outperforms existing conventional source detection algorithms, and the ensemble approach improves the overall performance of existing source detection and isotope identification algorithms. Furthermore, the AF algorithm and the Non-negative Matrix Factorization approach based source identification (NMF-ID) algorithm were combined and implemented on a singleboard microcontroller and the power consumption was measured. This ensemble algorithm reduced the power consumption of the NMF-ID algorithm almost by a factor of 100, while improving the detection performance of the overall system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An isotope harvesting beam blocker for the National Superconducting Cyclotron Laboratory

Harvesting isotopes from beam stops and other activated materials at accelerator facilities is a promising source of environmentally, scientifically and socially important radionuclides. At the Facility for Rare Isotope Beams (FRIB), a multitude of short- and long-lived radionuclides will be collected in a synergistic manner by dumping unused beams into a flowing-water beam stop. Ongoing exploratory research at the National Superconducting Cyclotron Laboratory (NSCL) with an analogous beam blocker aims towards obtaining the necessary radiochemical expertise for this endeavor. Herein we present a beam blocker and an isotope harvesting system which allows collection of a wide variety of aqueous and gaseous radionuclides. The water which flows through the beam blocker functions as an isotope production target and concurrently transports the newly formed radionuclides to collection sites. The system includes analytical instruments for online measurements of conductivity, dissolved oxygen, temperature, pressure and for detection of radiolytic products. To limit the levels of radiolytically produced hydrogen peroxide, a stainless-steel based degradation system was designed and implemented. Here, the suitability of the constructed system for the anticipated radionuclide harvesting project was demonstrated by offline tests and under irradiation with 140 MeV/u 48 Ca 20+ ions at the NSCL Coupled Cyclotron Facility.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Could Irradiation Introduce Oxidized Oxygen Signals in Resonant Inelastic X-ray Scattering of Battery Electrodes?

The characterization of oxidized oxygen states through high-efficiency mapping of resonant inelastic X-ray scattering (mRIXS) has become a crucial approach for studying the oxygen redox activities in high-energy battery cathodes. However, this approach has been recently challenged due to the concern of irradiation damage. In this work, we revisited a typical Li-rich electrode, Li 1.144 Ni 0.136 Mn 0.544 Co 0.136 O 2 , in both lithiated and delithiated states and evaluated the X-ray irradiation effect in the lengthy mRIXS experiments. Our results show that irradiation cannot introduce any oxidized oxygen feature, and the features of oxidized oxygen are weakened with a high X-ray dose. The results confirm again that mRIXS detects the intrinsic oxidized oxygen state in battery electrodes. However, the distinct irradiation effects in different systems imply that irradiation could selectively target the least stable elemental or chemical states, which should be analyzed with caution in the study of active chemical states.

25 ENERGY STORAGE↗

Effects of Quantum Dot Loading on the Radioluminescence Efficiency in Quantum-Dot-Embedded Composites

Nanoparticle-embedded plastic scintillators are an emerging technology for fast, large-area, high-resolution radiation detection and imaging. Here, this study investigates the properties of such composites, focusing on the effects of the quantum dot (QD) concentration on the radioluminescence (RL) intensity, spectra, and dynamics. Experiments using CdSe/CdS QDs in a polymer reveal a superlinear increase in RL with the QD concentration despite optical losses from inner filtering and interparticle interactions. When corrected for inner filtering, RL shows a quadratic concentration dependence, consistent with simple analytical models of improving the secondary electron capture. Practically, the benefits of high QD concentrations are muted by optical losses, but the findings apply to other systems with insulating hosts. In addition to manipulating emission for large effective Stokes shifts, future improvements may come from hosts with higher stopping power and better charge transport, which enable more effective funneling of excitations but without concomitant optical losses associated with high nanoparticle concentrations.

Auger recombination↗

Characterization of Self-Magnetic Pinch (SMP) Radiographic Diode Performance on RITS-6 at Sandia National Laboratories

The goals of an electron beam-driven radiographic source are the focusing of high current at high voltage to a minimal spot size with excellent shot-to-shot reproducibility. The Self-Magnetic Pinch (SMP) diode makes use of such an intense electron beam impinging on a high-atomic weight (tantalum) converter, a counter-streaming ion beam to help minimize the spot size, and operation in a magnetic field-free diode region which further encourages small spot size. Through a series of diode development experiments, output voltages up to 12.5 MV and output currents up to 225 kA have been characterized, with resulting spot sizes below ~ few mm. Scaling studies with parameter variation, such as diode aspect ratio and anode-cathode (A-K) gap variation, give systematic validation to what has heretofore been noted anecdotally by other research groups. While the lack of an imbedded magnetic field helps minimize the SMP spot size, a secondary result may be the generation of beam instabilities which can terminate the radiation pulse. There is anecdotal evidence that in-situ DC heating of the diode region can help stabilize the beam pinch. Clear experimental evidence exists that DC heating/RF cleaning results in better control over the counter-streaming ion population. Expanded use of spatial dose-rate detection is shown to yield new insights into electron beam dynamics in the SMP diode. An attendant study of the SMP diode as a load for an Inductive Voltage Adder (IVA) driver leads to insights into the behavior of the IVA-SMP diode configuration, viewed as a total system, and yields constraints on the overall impedance behavior of the SMP diode load.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Superconducting qubits for particle detection and fundamental tests of quantum mechanics

Many fundamental questions at the interface of quantum mechanics, gravity, and measurement remain relatively unexplored in the laboratory. These include whether spatial superpositions experience gravitational redshift, how the quantum Zeno effect propagates through entangled systems, and whether quantum information is globally conserved or fundamentally lost during measurement-induced wavefunction collapse. In this colloquium, I will discuss how superconducting qubits—developed primarily for quantum computing—can be repurposed as ultra sensitive detectors to probe these questions and to search for low-energy particle interactions. I will describe my work at Fermilab on stabilizing these devices to the level required for next-generation qubit-based sensors. This includes mitigating decoherence from infrared radiation and cosmic rays, using machine-learning techniques to accelerate superconducting qubit design, and leveraging the quantum Zeno effect to improve coherence times and suppress qubit frequency fluctuations. Together, these advances point toward a new class of quantum sensors capable of testing fundamental physics.

Seidel, Olivia [Fermilab]↗

Data Analysis of X-ray Panels Used in X-ray CT Scientific Instruments

This report is a follow-up study on M. Skeate’s study on System Drift Detection for Health Monitoring (Skeate, 2023). The following report highlights analyses of the panel’s behavior with extended use. This includes effects of burn-in on the panel from over-use and bad pixels (defined in Methodology.) Using data-forward statistical analyses across a sequence of scans, and given that the other conditions present in the data can be replicated, this study show that overtime use of panels does not affect bad pixel count. Also, I present conclusive evidence of a direct relationship between the regions of the panel that are exposed to radiation and burn-in damage to that region overtime. Additionally, this study also highlights the effect of the duty cycle on the dark current change in the panel.

42 ENGINEERING↗

Comparative Study of Quasi-Particle Burst Events in Transmon Qubits made with Different Materials and Geometries

Superconducting qubits are susceptible to various noise sources, including cosmic rays. ambient gamma and infrared radiation, which can significantly impact their performance. High-energy radiations deposit energy into the qubit substrate, generating high-energy phonons that disrupt Cooper pairs and create quasi-particles (QPs). Infrared photons, on the other hand can directly create QPs. The tunneling of these quasi-particles across Josephson junctions leads to qubit de-excitation and causes relaxation errors. In this study, we utilize a fast feedback mechanism for qubit reset to detect QP burst events with high time resolution [1]. We investigate transmon qubits fabricated with different encapsulations [2], geometries, and substrates at the above-ground laboratory of the Superconducting Quantum Materials and Systems (SQMS) center at Fermilab. Our preliminary results are presented, with discussions on their implications for the performance of modern quantum hardware. [1] Dominicis and Roy et al.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗