Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “quality assessment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Provenance–aware workflow for data quality management and improvement for large continuous scientific data streams

Data quality assessment, management and improvement is integral part of any big data intensive scientific research to ensure accurate, reliable and reproducible science discoveries. The task of maintaining the quality of data, however, is non-trivial and pose a challenge for a program like Department of Energy’s Atmospheric Radiation Measurement (ARM) that collects data from hundreds of instruments across the world,and distributes thousands of streaming data products that are continuously growing in near-real-time in an archive 1.7 Petabyte in size and growing. We present a computational data processing workflow to collect the data quality issue via an easy and intuitive web-based portal that allows reporting of any quality issues for any site, facility or instruments at a granularity down to individual variable in the data files. Portal allows instrument specialists and scientists to provide corrective actions in form of symbolic equation. A parallel processing framework applies the data improvement to large volume of data in efficient parallel environment, while optimizing data transfer and file I/O operations. Corrected files are systematically versioned and archived. A provenance tracking module tracks and records any change made to the data during its entire life cycle which are communicated transparently to the scientific users. Developed in Python using open source technologies, software architecture enables efficient and fast management and improvement of data in an operational data center environment.

Kumar, Jitendra↗

Visual Sample Plan Version 7.0 User's Guide

User's guide for VSP 7.0 This user's guide describes Visual Sample Plan (VSP) Version 7.0 and provides instructions for using the software. VSP selects the appropriate number and location of environmental samples to ensure that the results of statistical tests performed to provide input to risk decisions have the required confidence and performance. VSP Version 7.0 provides sample-size equations or algorithms needed by specific statistical tests appropriate for specific environmental sampling objectives. It also provides data quality assessment and statistical analysis functions to support evaluation of the data and determine whether the data support decisions regarding sites suspected of contamination. The easy-to-use program is highly visual and graphic. VSP runs on personal computers with Microsoft Windows operating systems (XP, Vista, Windows 7, and Windows 8). Designed primarily for project managers and users without expertise in statistics, VSP is applicable to two- and three-dimensional populations to be sampled (e.g., rooms and buildings, surface soil, a defined layer of subsurface soil, water bodies, and other similar applications) for studies of environmental quality. VSP is also applicable for designing sampling plans for assessing chem/rad/bio threat and hazard identification within rooms and buildings, and for designing geophysical surveys for unexploded ordnance (UXO) identification.

97 MATHEMATICS AND COMPUTING↗

Visual Sample Plan

VSP selects the appropriate number and location of environmental samples to ensure that the results of statistical tests performed to provide input to risk decisions have the required confidence and performance. VSP Version 5.0 provides sample-size equations or algorithms needed by specific statistical tests appropriate for specific environmental sampling objectives. It also provides data quality assessment and statistical analysis functions to support evaluation of the data and determine whether the data support decisions regarding sites suspected of contamination. The easy-to-use program is highly visual and graphic. VSP runs on personal computers with Microsoft Windows operating systems (98, NT, 2000, Millennium Edition, CE, and XP) Designed primarily for project managers and users without expertise in statistics, VSP is applicable to two- and three-dimensional populations to be sampled (e.g., rooms and buildings, surface soil, a defined layer of subsurface soil, water bodies, and other similar applications) for studies of environmental quality. VSP is also applicable for designing sampling plans for assessing chem./rad/bio threat and hazard identification within rooms and buildings, and for designing geophysical surveys for UXO identification.

Pulsipher, Brent↗

An Approach for Assessing the Signature Quality of Various Chemical Assays when Predicting the Culture Media Used to Grow Microorganisms

We demonstrate an approach for assessing the quality of a signature system designed to predict the culture medium used to grow a microorganism. The system was comprised of four chemical assays designed to identify various ingredients that could be used to produce the culture medium. The analytical measurements resulting from any combination of these four assays can be used in a Bayesian network to predict the probabilities that the microorganism was grown using one of eleven culture media. We evaluated combinations of the signature system by removing one or more of the assays from the Bayes network. We measured and compared the quality of the various Bayes nets in terms of fidelity, cost, risk, and utility, a method we refer to as Signature Quality Metrics

Holmes, Aimee E.↗

Data Qualification Framework

Proposed Data Qualification System Background Originally developed as a data qualification system for the Bioenergy Feedstock Library Provide data users a means of assessing data quality based on user driven quality metrics. Give users information regarding common data quality metrics to determine and assess the data quality. Potential Use Same type of quality assessment framework could be potentially applied to other databases and/or datasets for common assessment. Provide metric for assessment of appropriateness of data for various uses.

09 BIOMASS FUELS↗

Examples L-Band Interference will be Presented and Discussed, as well as the Importance of L-Band Soil Moisture Observations

Examples of L-band interference will be presented and discussed, as well as the importance of L-band soil moisture observations, as part of this one-day GEOSS workshop XXXVII on "Data Quality and Radio Spectrum Allocation Impact on Earth Observations" will address the broad challenges of data quality and the impact of generating reliable information for decision makers who are Earth data users but not necessarily experts in the Earth observation field. GEO has initiated a data quality assessment task (DA-09-01a) and workshop users will review and debate the directions and challenges of this effort. Radio spectrum allocation is an element of data availability and data quality, and is also associated with a GEO task (AR-06-11). A recent U.S. National Research Council report on spectrum management will be addressed as part of the workshop. Key representatives from industry, academia, and government will provide invited talks on these and related issues that impact GEOSS implementation.

Kim, Edward↗

Common practices for quantifying methane emissions from plumes detected by remote sensing

This document provides a set of community-accepted practices for quantifying methane emissions based on plumes detected via spectroscopic remote sensing. Its primary goal is to promote consistency in the generation, validation, reporting, and quality assessment of methane emission estimates derived from remote sensing radiances. Developed by subject matter experts with deep experience across all stages of the measurement process, this guidance reflects a critical evaluation of current methodologies and highlights key practices needed to produce reliable, interoperable, and traceable products. The focus is specifically on methane emissions quantified from distinct plumes originating from localized sources, rather than diffuse emissions spread over large regions, which are beyond the scope of this work. This document is intended to serve both data producers and users. For producers, it offers a framework for aligning with field-recognized standards to ensure their outputs meet rigorous quality and transparency criteria. For users, it provides a reference to assess dataset fitness-for-purpose by highlighting essential metadata, assumptions, and methodological choices that underpin emission estimates. By fostering a shared understanding of best practices, this work aims to enhance comparability, confidence, and utility of remotely sensed methane emission products.

54 ENVIRONMENTAL SCIENCES↗

Ninth Annual NASA/Contractors Conference on Quality and Productivity. World Class Excellence: The Journey Continues. Conference presentations

The topics covered include the following: The George M. Low Trophy; total quality assessment and measurement; using award criteria to improve organizational effectiveness; results--keeping an eye on the bottom line; capturing customer satisfaction; moving from management to leadership; leadership versus management; transforming the management team; leadership success stories; success stories in the quest for excellence; small business successes; education success stories; government success stories; tools and techniques for total quality management (TQM) integration; planning and organizing for TQM integration; successful stories for implementing system level TQM/CI tools; assessing TQM results; establishing an environment for continuous improvement at NASA; empowerment; synergism of partnering; and partnerships in education.

Templeton, Geoffrey B.↗

Recommendations for mass spectrometry data quality metrics for open access data(corollary to the Amsterdam principles)

Policies supporting the rapid and open sharing of proteomic data are being implemented by the leading journals in the field. The proteomics community is taking steps to ensure that data are made publicly accessible and are of high quality, a challenging task that requires the development and deployment of methods for measuring and documenting data quality metrics. On September 18, 2010, the U.S. National Cancer Institute (NCI) convened the 'International Workshop on Proteomic Data Quality Metrics' in Sydney, Australia, to identify and address issues facing the development and use of such methods for open access proteomics data. The stakeholders at the workshop enumerated the key principles underlying a framework for data quality assessment in mass spectrometry data that will meet the needs of the search community, journals, funding agencies, and data repositories. Attendees discussed and agreed upon two primary needs for the wide use of quality metrics: (i)an evolving list of comprehensive quality metrics and (ii)standards accompanied by software analytics. Attendees stressed the importance of increased education and training programs to promote reliable protocols in proteomics. This workshop report explores the historic precedents, key discussions, and necessary next steps to enhance the quality of open access data. By agreement, this article is published simultaneously in Proteomics, Proteomics Clinical Applications, Journal of Proteome Research, and Molecular and Cellular Proteomics, as a public service to the research community.The peer review process was a coordinated effort conducted by a panel of referees selected by the journals.

59 BASIC BIOLOGICAL SCIENCES↗

Failure Mode Classification for Life Prediction Modeling of Solid-State Lighting

Since the passing of the Energy Independence and Security Act of 2007, the U.S. government has mandated greater energy independence which has acted as a catalyst for accelerating and facilitating research efforts toward the development and deployment of market-driven solutions for energy-saving homes, buildings and manufacturing, as well as sustainable transportation and renewable electricity generation. As part of this effort, an emphasis toward advancing solid-state lighting technology through research, development, demonstration, and commercial applications is assisting in the phase out of the common incandescent light bulb, as well as developing a more economical lighting source that is less toxic than compact fluorescent lighting. This has led lighting manufacturers to pursue SSL technologies for a wide range of consumer lighting applications. An SSL luminaire’s lifetime can be characterized in terms of lumen maintenance life. Lumen maintenance or lumen depreciation is the percentage decrease in the relative luminous flux from that of the original, pristine luminous flux value. Lumen maintenance life is the estimated operating time, in hours, when the desired failure threshold is projected to be reached at normal operating conditions. One accepted failure threshold of SSL luminaires is lumen maintenance of 70% -- a 30% reduction in the light output of the luminaire. Currently, the only approved lighting standard that puts forth a recommendation for long-term luminous flux maintenance projections towards a specified failure threshold of an SSL luminaire is the IES TM-28-14 (TM28) standard. iii TM28 was derived as a means to compare luminaires that have been tested at different facilities, research labs or companies. TM28 recommends the use of the Arrhenius equation to determine SSL device specific reaction rates from thermally driven failure mechanisms used to characterize a single failure mode – the relative change in the luminous flux output or “light power” of the SSL luminaire. The use of the Arrhenius equation necessitates two different temperature conditions, 25°C and 45°C are suggested by TM28, to determine the SSL lamp specific activation energy. One principal issue with TM28 is the lack of additional stresses or parameters needed to characterize non-temperature dependent failure mechanisms. Another principal issue with TM28 is the assumption that lumen maintenance or lumen depreciation gives an adequate comparison between SSL luminaires. Additionally, TM28 has no process for the determination of acceleration factors or lifetime estimations. Currently, a literature gap exists for established accelerated test methods for SSL devices to assess quality, reliability and durability before being introduced into the marketplace. Furthermore, there is a need for Physics-of-Failure based approaches to understand the processes and mechanisms that induce failure for the assessment of SSL reliability in order to develop generalized acceleration factors that better represent SSL product lifetime. This and the deficiencies in TM28 validate the need behind the development of acceleration techniques to quantify SSL reliability under a variety of environmental conditions. The ability to assess damage accrual and investigate reliability of SSL components and systems is essential to understanding the life time of the SSL device itself. The methodologies developed in this work increases the understanding of SSL devices iv through the investigation of component and device reliability under a variety of accelerated test conditions. The approaches for suitable lifetime predictions through the development of novel generalized acceleration factors, as well as a prognostics and health management framework, will greatly reduce the time and effort needed to produce SSL acceleration factors for the development of lifetime predictions.

Sakalaukus, Peter Joseph↗

Strategic Environmental Assessment as catalyst of healthier spatial planning: The Danish guidance and practice

A wide range of factors within spatial planning can affect health. There is therefore an important scope for Strategic Environmental Assessment (SEA) of spatial plans to protect and improve human health. Due to the EU Directive 2001/42/EC on SEA, health has been made explicit in Danish legislation and guidance. This paper examines the inclusion of health as a formal component in impact assessment of spatial plans. Based upon a documentary study of 100 environmental reports, the paper analyses and discusses how health impact considerations are incorporated in SEA practice. It is found that health impacts are included in SEA practice and are being interpreted in a broader sense than what the national guidance exemplifies. The frequent included health aspects are noise, drinking water, air pollution, recreation/outdoor life and traffic safety. The primary determinant for health is transport-whether it is at the overall or local planning level. The main conclusion is that SEA shows a potential to catalyse healthier spatial planning. Despite the broad inclusion of health in SEA practice the examination shows potential improvements, hereunder qualification of assessments by better explaining the nature and significance of impacts and by including the distributional aspects of human health impacts. Inclusion from the health sector is put forward as an important institutional mean to secure cross disciplinarily and higher quality assessment.

54 ENVIRONMENTAL SCIENCES↗

Effectiveness of Reirradiation for Painful Bone Metastases: A Systematic Review and Meta-Analysis

Purpose: Reirradiation of painful bone metastases in nonresponders or patients with recurrent pain after initial response is performed in up to 42% of patients initially treated with radiotherapy. Literature on the effect of reirradiation for pain control in those patients is scarce. In this systematic review and meta-analysis, we quantify the effectiveness of reirradiation for achieving pain control in patients with painful bone metastases. Methods and Materials: A free text search was performed to identify eligible studies using the MEDLINE, EMBASE, and the Cochrane Collaboration library electronic databases. After study selection and quality assessment, a pooled estimate was calculated for overall pain response for reirradiation of metastatic bone pain. Results: Our literature search identified 707 titles, of which 10 articles were selected for systematic review and seven entered the meta-analysis. Overall study quality was mediocre. Of the 2,694 patients initially treated for metastatic bone pain, 527 (20%) patients underwent reirradiation. Overall, a pain response after reirradiation was achieved in 58% of patients (pooled overall response rate 0.58, 95% confidence interval = 0.49-0.67). There was a substantial between-study heterogeneity (I{sup 2} = 63.3%, p = 0.01) because of clinical and methodological differences between studies. Conclusions: Reirradiation of painful bone metastases is effective in terms of pain relief for a small majority of patients; approximately 40% of patients do not benefit from reirradiation. Although the validity of results is limited, this meta-analysis provides a comprehensive overview and the most quantitative estimate of reirradiation effectiveness to date.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Assess Calibration Consistency of MODIS and AVHRR Thermal Infrared Bands Using SNO Observations Corrected for Atmospheric Effects

Monitoring environmental changes from space requires extremely well-calibrated observations to achieve the necessary high accuracy and stability. The calibration differences between the Moderate Resolution Imaging Spectroradiometer (MODIS) and the Advanced Very High Resolution Radiometer (AVHRR) thermal bands provide a valuable quality assessment of the instrument performance. This letter compares the calibration differences between the Aqua MODIS and NOAA-18 AVHRR bands at 11.0 and 12.0 /Lm using simultaneous nadir overpass observations obtained in nearly parallel orbits. Impacts due to the relative spectral-response differences between the two sensors are estimated by MODTRAN simulations with real-time atmospheric profiles of temperature, water vapor, atmospheric pressure and ozone, and surface skin temperatures. Results show that the temperature difference after the removal of atmospheric impacts is within 0.30 K (or 0.40% in radiance) across the effective calibration range (or the 1l.0 l'm band/channel. For the 12.0 pm band, the differences are OAO K (or 0.50%) at the typical radiance and up to 0.70 K (or 0.90%) close to the maximum radiance, indicating an excellent calibration consistency between MODIS and AVHRR for both bands.

Wu, Aisheng↗

6S Return Samples: Assessment of Air Quality in the International Space Station (ISS) Based on Solid Sorbent Air Sampler (SSAS) and Formaldehyde Monitoring Kit (FMK) Analyses

The toxicological assessments of SSAS and FMK analytical results are reported. Analytical methods have not changed from earlier reports. Surrogate standard recoveries from the SSAS tubes were 66-76% for 13C-acetone, 85-96% for fluorobenzene, and 73-89% for chlorobenzene. Post-flight flows were far below pre-flight flows and an investigation of the problem revealed that the reduced flow was caused by a leak at the interface of the pump inlet tube and the pump head. This resulted in degradation of pump efficiency. Further investigation showed that the problem occurred before the SSAS was operated on orbit and that use of the post-flight flows yielded consistent and useful results. Recoveries from formaldehyde control badges were 86 to 104%. The two general criteria used to assess air quality are the total-non-methane-volatile organic hydrocarbons (NMVOCs) and the total T-value (minus the CO2 and formaldehyde contributions). The T values will not be reported for these data due to the flow anomaly. Control of atmospheric alcohols is important to the water recovery system engineers, hence total alcohols (including acetone) are also shown for each sample. Octafluoropropane (OFP) is not efficiently trapped by the sorbents used in the SSAS. Because formaldehyde is quantified from sorbent badges, its concentration is also listed separately. These five indices of air quality are summarized.

James, John T.↗

Composites From in-Situ Consolidation Automated Fiber Placement of Thermoplastics for High-Rate Aircraft Manufacturing

The National Aeronautics and Space Administration (NASA) project Hi-Rate Composites Aircraft Manufacturing (HiCAM) aims to significantly increase commercial aircraft composite structures manufacturing rate. Thermoplastic composites offer attractive solutions to rapid manufacturing due to their ability to be formed and consolidated quickly. NASA has a particular interest in assessing composite structure manufacturing utilizing an in-situ consolidation automated fiber placement (AFP) of thermoplastics (ICAT) process employing current state-of-the-art laser heating systems. Three semi-crystalline polyaryletherketone (PAEK) thermoplastic tape materials were characterized to ascertain the ICAT process parameters. The required laser power settings were determined at Electroimpact, Inc., measuring material temperatures utilizing a forward looking infrared (FLIR) thermal imaging camera and thermocouples. The material temperature, tool temperature, and placement speed were varied for resulting consolidation quality assessment. The resulting temperature data were also utilized to calibrate thermal analysis models under development at NASA. The experimental temperature data confirmed analytical results. The quality of the resulting test panels was evaluated by both non-destructive evaluation as well as destructively by photo-microscopy. The effect on interlaminar strength was determined by short beam strength testing. Test results of carbon fiber laminates fabricated by ICAT using polyetheretherketone (PEEK), polyetherketoneketone (PEKK), and low-melt polyaryletherketone (LM-PAEK) at various placement temperatures and placement speeds are presented.

thermoplastic composites↗

Data Quality Challenges for Analysis Ready Data (ARD)

Data quality plays a critical role in research and applications. The Earth Science Information Partners (ESIP) Information Quality Cluster (IQC) defines four aspects of information quality: Science, Product, Stewardship, and Services. The ESIP IQC has become internationally recognized as an authoritative and responsive resource of information and guidance to data producers and distributors on how to implement data quality standards and best practices for their science data systems, datasets, and data/metadata dissemination services. In recent years, cloud computing environments have provided scale-up capabilities such as data archives and services, enabling interdisciplinary science and applications. More value-added products are expected from data service providers, including Analysis Ready Data (ARD). ARD refers to data that has been preprocessed into a form that allows immediate analysis by the end user, processed to a minimum set of requirements and provides interoperability over time and across multiple datasets. Once a dataset has been developed from its original form to produce ARD, what quality characteristics should the derived dataset or ARD possess? Also, is it safe to assume that the quality of the ARD is consistent with the quality of the source data, or are there special attributes to an ARD that would warrant a secondary, independent quality assessment? What provenance (also called “data lineage”) information needs to be included in ARD? It is important to answer these questions, especially given the ease of use of ARD, and the consequent temptation by users to trust ARD without understanding the limitations or possible variations in quality compared to the source data. In this presentation, we will discuss data quality challenges for ARD products and services and introduce IQC for participation.

data quality↗

Four-dimensional intensity-modulated radiation therapy planning for dynamic tracking using a direct aperture deformation (DAD) method

Purpose: Planning for the delivery of intensity-modulated radiation therapy (IMRT) to a moving target, referred to as four-dimensional (4D) IMRT planning, is a crucial step for achieving the treatment objectives for sites that move during treatment delivery. The authors proposed a simplistic method that accounts for both rigid and nonrigid respiration-induced target motion based on 4D computed tomography (4DCT) data sets. Methods: A set of MLC apertures and weights was first optimized on a reference phase of a 4DCT data set. At each beam angle, the apertures were morphed from the reference phase to each of the remaining phases according to the relative shape changes in the beam's eye view of the target. Three different planning schemes were evaluated for two lung cases and one pancreas patient: (1) Individually optimizing each breathing phase; (2) optimizing the reference phase and shifting the optimized apertures to other breathing phases based on a rigid-body image registration; and (3) optimizing the reference phase and deforming the optimized apertures to the other phases based on the deformation and translation of target contours. Planning results using scheme 1 serves as the ''gold standard'' for plan quality assessment; scheme 2 is the method previously proposed in the literature; and scheme 3 is the method the authors proposed in this article. The optimization results were compared between the three schemes for all three cases. Results: The proposed scheme 3 is comparable to scheme 1 in plan quality, and provides improved target coverage and conformity with similar normal tissue dose compared with scheme 2. Conclusions: Direct aperture deformation method for 4D IMRT planning improves upon methods that only consider rigid-body motion and achieves a plan quality close to that optimized for each of the phases.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Use of a line-pair resolution phantom for comprehensive quality assurance of electronic portal imaging devices based on fundamental imaging metrics

Image guided radiation therapy solutions based on megavoltage computed tomography (MVCT) involve the extension of electronic portal imaging devices (EPIDs) from their traditional role of weekly localization imaging and planar dose mapping to volumetric imaging for 3D setup and dose verification. To sustain the potential advantages of MVCT, EPIDs are required to provide improved levels of portal image quality. Therefore, it is vital that the performance of EPIDs in clinical use is maintained at an optimal level through regular and rigorous quality assurance (QA). Traditionally, portal imaging QA has been carried out by imaging calibrated line-pair and contrast resolution phantoms and obtaining arbitrarily defined QA indices that are usually dependent on imaging conditions and merely indicate relative trends in imaging performance. They are not adequately sensitive to all aspects of image quality unlike fundamental imaging metrics such as the modulation transfer function (MTF), noise power spectrum (NPS), and detective quantum efficiency (DQE) that are widely used to characterize detector performance in radiographic imaging and would be ideal for QA purposes. However, due to the difficulty of performing conventional MTF measurements, they have not been used for routine clinical QA. The authors present a simple and quick QA methodology based on obtaining the MTF, NPS, and DQE of a megavoltage imager by imaging standard open fields and a bar-pattern QA phantom containing 2 mm thick tungsten line-pair bar resolution targets. Our bar-pattern based MTF measurement features a novel zero-frequency normalization scheme that eliminates normalization errors typically associated with traditional bar-pattern measurements at megavoltage x-ray energies. The bar-pattern QA phantom and open-field images are used in conjunction with an automated image analysis algorithm that quickly computes the MTF, NPS, and DQE of an EPID system. Our approach combines the fundamental advantages of linear systems metrics such as robustness, sensitivity across the full spatial frequency range of interest, and normalization to imaging conditions (magnification, system gain settings, and exposure), with the simplicity, ease, and speed of traditional phantom imaging. The algorithm was analyzed for accuracy and sensitivity by comparing with a commercial portal imaging QA method (PIPSPRO, Standard Imaging, Middleton, WI) on both first-generation lens-coupled and modern a-Si flat-panel based clinical EPID systems. The bar-pattern based QA measurements were found to be far more sensitive to even small levels of degradation in spatial resolution and noise. The bar-pattern based QA methodology offers a comprehensive image quality assessment tool suitable for both commissioning and routine EPID QA.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗