Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “pumps”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Apparatus for Pumping a Fluid

A fluid pump has been developed for mechanically pumped fluid loops for spacecraft thermal control. Lynntech's technology utilizes a proprietary electrochemically driven pumping mechanism. Conventional rotodynamic and displacement pumps typically do not meet the stringent power and operational reliability requirements of space applications. Lynntech's developmental pump is a highly efficient solid-state pump with essentially no rotating or moving components (apart from metal bellows).

Boeyen, Robert Van↗

Condition Based vs. Time Based Maintenance: Case Study on Hypergolic Pumps

Two Pad 39B Ox pumps were monitored with the Baker Instruments Explorer Motor tester. Using the torque spectrum it was determined that Ox pump #2 had a significant peak at a frequency, which indicated lubricant fluid whirl. Similar testing on Ox pump #1 didn't indicate this peak, an indication that this pump was in good mechanical condition. Subsequent disassembly of both motors validated these findings. Ox pump #2 rear bearing showed significant wear, the front bearing showed little wear. Ox pump #1 was still within manufacturers tolerances.

Gibson, Lewis J.↗

Multiphysics Modeling of an Annular Linear Induction Pump With Applications to Space Nuclear Power Systems

An annular linear induction pump (ALIP) that could be used for circulating liquid-metal coolant in a fission surface power reactor system is modeled in the present work using the computational COMSOL Multiphysics package. The pump is modeled using a two-dimensional, axisymmetric geometry and solved under conditions similar to those used during experimental pump testing. Real, nonlinear, temperature-dependent material properties can be incorporated into the model for both the electrically-conducting working fluid in the pump (NaK-78) and structural components of the pump. The intricate three-phase coil configuration of the pump is implemented in the model to produce an axially-traveling magnetic wave that is qualitatively similar to the measured magnetic wave. The model qualitatively captures the expected feature of a peak in efficiency as a function of flow rate.

Kilbane, J.↗

Apparatus for Pumping a Fluid

An electrochemically actuated pump and an electrochemical actuator for use with a pump. The pump includes one of various stroke volume multiplier configurations with the pressure of a pumping fluid assisting actuation of a driving fluid bellows. The electrochemical actuator has at least one electrode fluidically coupled to the driving fluid chamber of the first pump housing and at least one electrode fluidically coupled to the driving fluid chamber of the second pump housing. Accordingly, the electrochemical actuator selectively pressurizes hydrogen gas within a driving fluid chamber. The actuator may include a membrane electrode assembly including an ion exchange membrane with first and second catalyzed electrodes in contact with opposing sides of the membrane, and first and second hydrogen gas chambers in fluid communication with the first and second electrodes, respectively. A controller may reverse the polarity of a voltage source electrically coupled to the current collectors.

van Boeyen, Roger W.↗

Pumping Loss of Shrouded Meshed Spur Gears

High speed rotorcraft transmissions are subject to load-independent power losses consisting of drag loss and pumping loss. Tightly conforming shrouds enclosing the transmission gears are often incorporated to reduce the drag component of the total load-independent losses. However, tightly conforming axial shrouds can result in an increase in the pumping loss component. Quantifying the pumping loss of shrouded gear transmissions has been the subject of many studies. This study presents a new approach for estimating pumping loss based on the concept of swept volume and examines the applicability of the approach to various shroud configurations.The drag loss and pumping loss of a shrouded spur gear pair has been determined through testing using the NASAGlenn Research Center (GRC) Gear Windage Test Facility.The results from this testing have been compared to theoretical results using the formulations presented in this study. In addition, computational fluid dynamic (CFD) analysis has been conducted for the various shroud configurations tested at NASA GRC. The results from the CFD analysis confirm the theoretical and empirical results and provide insight into the applicability of the swept volume approach for estimating pumping power loss of shrouded gear transmissions.

Michael J. Hurrell↗

VALVE TIMING AND AREA PROFILE SELECTION FOR HYDRAULIC PUMPS AND MOTORS

A significant amount of research has been conducted to select valve timing and area profiles that create efficient and quiet hydraulic pumps and motors. Numerous active valve architectures have been modeled and optimized, but the rationale for the final solution is often unclear. The solution is usually highly dependent on the modeled valve geometry constraints and the duty cycle of the pump or motor for which the valve was optimized. This paper first presents an ideal valve area profile and what compromises are made to design for a working pressure and speed range. The ideal valve area profile is resolved using a piston-cylinder model with a pressure dependent bulk modulus and variable valve openings. The piston-cylinder is first modeled as a pump with passive (check) valves and a specified pressure drop across the valves to determine the ideal area profile. A generalization of the ideal timing is demonstrated for positive pressure differential and positive rotation direction, also known as the first quadrant. The effects on valve timing when varying pressure are shown for the first quadrant, but the trends can be extrapolated for all quadrants of operation. The ideal valve profile is implemented as fixed valve timing, meaning the valve area is only a function of the timing angle, in a pump-motor. The pump-motor is simulated in one rotation direction through a pressure range. Performance is high in pumping operation, but when the pressure differential is reversed, cylinder pressure spikes ensue. Two strategies to modify an ideal valve area profile are presented: timing grooves and a pressure shifted valve timing. Timing grooves reduce pressure spikes and cavitation in the cylinder but generally increase throttling losses. A pressure shifted valve timing has lower throttling energy losses, making it the favored solution.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Heat pumps in the United States: Market potentials, challenges and opportunities, technology advances

The US heat pump market has been affected by the socioeconomic impacts of the COVID-19 pandemic. However, the Biden administration’s goal of net-zero greenhouse gas emissions by 2050 through electrification and clean energy technologies is accelerating the research, development, and deployment of heat pumps in the United States for improved energy performance, reduced greenhouse gas emissions, and wider adoption. The US heat pump market has experienced steady growth since 2010. In 2020, heat pumps surpassed gas furnace shipments for the first time, and the trend maintains through 2022. The current priority is to improve the affordability of energy and equitable access to heat pump technologies through cost reductions and further accelerate this trend. In addition, current R&D includes emphases on alternative refrigeration technology and lower–global warming potential refrigerants to reduce direct emissions. Heat pump market share is expected to grow as regulatory policies and financial incentives steer the building sector toward decarbonization. This paper reviews policies and market trends, discusses the challenges and opportunities in the current policy landscape, and reviews current research in the United States.

Malhotra, Mini↗

High Temperature Heat Pumps and Their Roles in the Decarbonization of Building and Industry

Heat pumps have been sought as a promising technology for air and water heating processes in buildings. Several OEMs have been commercializing heat pumps with varying capacities; However, the application has been limited to lower temperatures (less than 70℃). With the recently growing interest in replacing gas-fired equipment for buildings and industrial processes, a new class of heat pumps, known as high-temperature heat pumps, is gaining substantial interest where the target temperatures are higher than the conventional heat pump technology (greater than 90℃). The current study is focused on this class of heat pumps and aims to provide a holistic overview of state-of-the-art technology while highlighting major challenges and opportunities. The discussion will be focused on the availability of technology to enable higher sink temperatures, deployment-based applications, waste heat recovery, and process integration and controls.

Nawaz, Kashif↗

A Preliminary Investigation on the Performance of a Dual-Source Heat Pump using both the Air and the Ground

Air source heat pumps (ASHPs) and ground source heat pumps (GSHPs) are the two most common types of electric-driven heat pumps in the marketplace to replace fossil fuel-based heating systems. However, the performance and efficiency of ASHPs depend on the ambient air conditions. Therefore, ASHPs usually are equipped with electric resistance heaters to provide supplemental heating when the ambient temperature is low, and the heating demand is high. The electric resistance heaters could result in high power draws when they are turned on. On the other hand, due to the relatively steady temperature of the ground, GSHPs are more energy efficient than ASHPs when providing space heating and cooling to the buildings. However, the adoption of GSHP is hindered by its high initial cost, mostly due to the cost of drilling boreholes for installing ground heat exchangers (GHE). To solve the above issues, our study investigates the performance of dual-source heat pumps (DSHPs) with respect to that of ASHPs and GSHPs. The DSHP will use ambient air when its temperature is favorable for the efficient operation of the heat pump. When the ambient temperature is too hot or too cold, the ground source will be utilized to retain the high-efficiency operation of the heat pump. Because the cumulative thermal load of the GHE is shared with the ambient air, the size of the GHE could be smaller than those of the conventional GSHPs. The study will model the DSHP and simulate its performance in providing heating and cooling for a typical single-family house in regions with hot, mild, or cold climates. In addition, the required GHE size of the DSHP system will be determined through annual simulations and compared with that of conventional GSHPs.

Anees, Fady↗

A Multifaceted Analysis of Chemical-Absorption Heat Pump Technology for Integrated Energy Systems

Integrated Energy Systems (IES) research and development is essential for improving the economic usage of lowcarbon energy sources such as nuclear power, solar, and wind in the U.S. An ideal IES uses various energy sources and delivers energy to the power grid and industry as efficiently as possible. As part of this effort, there are many opportunities to use low-carbon energy for industries requiring process heat for production of many chemicals and fuels [1]. Currently, industries only have the option to burn CO2 emitting fuels or use resistance heaters for this process heat. Using resistance heaters is one way to electrify a process, allowing for low-carbon energy sources to be used, but is an inefficient method unless temperatures exceed 1000?C. Heat pumps have long been used to provide efficient heating or cooling by moving heat instead of generating it. More traditional heat pumps such as vapor compression heat pumps and absorption heat pumps are limited to temperatures below 300?C due to refrigerant and component material limits. However, chemical heat pumps have been investigated as an option for pumping heat at temperatures above 600?C [2], making the heat more applicable to many more chemical and fuel production processes.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Preliminary Assessment for the Electric Load Shifting Potential of Integrating Thermal Energy Storage with Heat Pumps in Residential Buildings in Texas of United States

The widespread adoption of electric-driven heat pumps for heating and cooling is expected to significantly increase electric demand. Cooling electric demand will result in an increase in peak hours electric loads, placing additional strain on the grid during peak hours. This challenge, combined with the current rapidly increasing demand from data centers, exacerbates the electric demand duck curve problem. Integrating thermal energy storage (TES) with heat pump can shift electric use for heating and cooling from peak to off-peak hours of the electric grid, which can help flatten the daily electric demand profile of a building. This paper presents a novel design that integrates heat pump with TES (HP-TES), which uses phase change materials (PCM). Heat pump charges TES by melting or freezing PCM during off-peak hours when there is no thermal demand from the building. TES is then discharged (i.e., by freezing or melting PCM) during peak hours to provide a more favorable heat source or heat sink for the heat pump to meet the thermal demand of the building with lower electricity use than conventional air-source heat pumps. Computer simulations were developed to predict the performance of HP-TES applied to a typical single-family house in the US. The building-level simulation results were scaled up to preliminarily assess the aggregated impacts of deploying HP-TES across all single-family houses in Texas of the United States, including reduction of peak demand of the electric grid.

Anees, Fady [ORNL]↗

Investigation of a high-temperature combination heat pump for lower-cost electrification in multifamily buildings

The development of space and water heating combination heat pumps capable of generating water temperatures high enough for convective heat emitters will enable more cost-effective and equitable decarbonization solutions for electrifying multifamily buildings. Here, in this paper, multifamily building models and a charge-sensitive mechanistic cycle model of a combination heat pump are developed, and the system performance is predicted based on the models. Unlike other state-of-the-art residential heat pumping equipment, the modeled combination heat pump using an economized, fluid-injected variable-speed compressor can achieve higher temperature lifts of 40° - 85°C, with lower installation costs and complexity. The model predicted heating coefficient of performance (COP h ) is 2.1 at an ambient temperature of -15°C with a high-temperature lift of nearly 85°C, and a seasonal coefficient of performance in heating mode (SCOP h ) ranges from 2 - 4 for different locations. The system shows 30% - 90% lower CO 2 eq emissions over a condensing gas boiler and 9% - 13% lower projected installation costs than two separate space and water heat pumping appliances.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Final Design of Vacuum Pumping Systems for the Material Plasma Exposure eXperiment

The Material Plasma Exposure eXperiment (MPEX) vacuum pumping system is responsible for creating prototypic conditions in the plasma material interaction chamber that mimic those in a fusion reactor divertor region. Additionally, the vacuum system needs to minimize the pressure in the plasma heating region to improve the coupling of the electron cyclotron heating and ion cyclotron heating to the plasma, minimizing waste heat exhausted to high heat flux components. Here, the final design of the system has been sized to comply with the vacuum pump operating environment and to reduce the number of unique pumps required while meeting performance requirements. Bounding cases with and without the plasma present have been developed in the pumping analysis, and an initial calculation has been performed based on the plasma pumping identified in Proto-MPEX operation though this result will remain unverified until MPEX operation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optimized Biasing of Pump Laser Diodes in a Highly Reliable Metrology Source for Long-Duration Space Missions

Optical metrology system reliability during a prolonged space mission is often limited by the reliability of pump laser diodes. We developed a metrology laser pump module architecture that meets NASA SIM Lite instrument optical power and reliability requirements by combining the outputs of multiple single-mode pump diodes in a low-loss, high port count fiber coupler. We describe Monte-Carlo simulations used to calculate the reliability of the laser pump module and introduce a combined laser farm aging parameter that serves as a load-sharing optimization metric. Employing these tools, we select pump module architecture, operating conditions, biasing approach and perform parameter sensitivity studies to investigate the robustness of the obtained solution.

808 mm diode pumps↗

Impact Analysis of Transitioning to Heat Pump Rooftop Units for the U.S. Commercial Building Stock: Preprint

20% of the U.S. commercial building sector's energy usage is from on-site combustion of fossil fuels for heating. Decarbonization will require electrification of these systems to meet climate goals, often by transitioning to heat pumps. Rooftop units (RTU) are the most prominent commercial building HVAC system type and should therefore be prioritized for decarbonization solutions. However, there is limited understanding of the impact on emissions that considers regional electricity generation methods, as well as the impact of other heat pump intricacies such as the effects of temperature on capacity/efficiency, defrost operation, realistic sizing methodologies, and supplementary heating. This study explores the effects of transitioning all conventional RTUs to high-performance heat pump RTUs for the U.S. commercial building stock. The analysis is performed using ComStock, DOE's calibrated model of the U.S. commercial building stock developed by NREL. Results show 9% and 17% reductions in stock aggregate energy consumption and GHG emissions, respectively. Furthermore, average heat pump operational details are presented by state. This analysis will help inform the transition to heat pump RTUs for the U.S. commercial building stock.

commercial building electrification↗

Superhydrophobic heat exchangers delay frost formation and enhance efficency of electric vehicle heat pumps

The number of electric vehicles has rapidly expanded as high-performance automotive lithium-ion batteries have become more affordable. However, the range of electric vehicles decreases in cold climates partly because of the additional thermal loads associated with cabin heating. One way to improve the efficiency of cabin heating is to replace resistive heating elements with an air-source heat pump system. However, to gain the full benefit of heat pumping, frost formation on the outdoor heat exchanger must be minimized. In this work, we modified the surface wettability of aluminum louvered-fin automotive heat pump evaporators and tested them under realistic operating conditions in a transcritical carbon dioxide (CO 2 ) heat pump. Each heat exchanger underwent several consecutive frosting and defrosting cycles to understand the cyclic performance of the system. The heat exchanger with a superhydrophobic outer surface was able to delay frost formation and maintain higher heat transfer rates when compared to heat exchangers with higher surface energies (hydrophilic). The delayed frost formation resulted in a system efficiency benefit in the first few frosting cycles but diminished in later cycles due to water retention and incomplete defrosting. However, for most automotive applications the superhydrophobic heat exchanger showed substantial benefits for normal driving trips. We report the scalable and optimized superhydrophobic heat exchangers developed here have the potential to increase the efficiency of automotive heat pumps and consequently increase the range and reduce energy consumption of electric vehicles.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Enhanced spin pumping in heterostructures of coupled ferrimagnetic garnets

Spin pumping has significant implications for spintronics, providing a mechanism to manipulate and transport spins for information processing. Understanding and harnessing spin currents through spin pumping is critical for the development of efficient spintronic devices. The use of a magnetic insulator with low damping enhances the signal-to-noise ratio in crucial experiments such as spin-torque ferromagnetic resonance (FMR) and spin pumping. A magnetic insulator coupled with a heavy metal or quantum material offers a more straightforward model system, especially when investigating spin-charge interconversion processes to greater accuracy. This simplicity arises from the absence of unwanted effects caused by conduction electrons unlike in ferromagnetic metals. Here, we investigate the spin pumping in coupled ferrimagnetic (FiM) Y 3 Fe 5 O 12 (YIG)/Tm 3 Fe 5 O 12 (TmIG) bilayers combined with heavy-metal (Pt) using the inverse spin Hall effect. It is observed that magnon transmission occurs at both of the FiMs FMR positions. The enhancement of spin pumping voltage (V sp ) in the FiM garnet heterostructures is observed. The plausible reason might be the interfacial exchange coupling between FiMs. The modulation of V sp is achieved by tuning the bilayer structure. Further, the spin mixing conductance for these coupled systems is found to be ≈ 10 18 m –2 . Furthermore, our findings describe a coupled FiM system for the investigation of magnon coupling providing opportunities for magnonic devices.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High Compression in Palladium Alloy Metal Foil Pumps

Metal foil pumps (MFPs) are key components in the direct internal recycling inner fuel cycle loop for the recovery of hydrogen isotopes from deuterium-tritium fusion exhaust. Operating under vacuum conditions, they utilize superthermal hydrogen as the feed gas in a process called superpermeation. A notable feature of MFPs is their ability to pump against a pressure gradient. This study examines the compression capabilities of PdAg and PdCu MFPs at low temperatures with a constant feed pressure of 10 Pa. At 75°C, compression ratios exceeding 200 were readily achieved, with downstream pressures exceeding 4500 Pa using PdCu. For both alloys, net fluxes decreased by only ~15% at downstream pressures of 1000 Pa, which offers potential simplifications for the downstream pump train. Performance declined markedly when the temperature was elevated to 200°C. Pump curves were constructed and advocated as the most appropriate manner to assess MFP performance. Separate pressure-driven-permeation experiments at relevant conditions were conducted, providing a direct measurement of the hydrogen dissociation constant $k$ d , which was found to be in good agreement with the previous literature. Further, these measurements were used to predict pump curves and maximum compression ratios by balancing superpermeation with pressure-driven permeation, achieving excellent agreement with experiment. Last, experiments using asymmetric MFPs revealed the detrimental impact that surface impurities have on performance in this system.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗