Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “pulse position modulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

New Technique of High-Performance Torque Control Developed for Induction Machines

Two forms of high-performance torque control for motor drives have been described in the literature: field orientation control and direct torque control. Field orientation control has been the method of choice for previous NASA electromechanical actuator research efforts with induction motors. Direct torque control has the potential to offer some advantages over field orientation, including ease of implementation and faster response. However, the most common form of direct torque control is not suitable for the highspeed, low-stator-flux linkage induction machines designed for electromechanical actuators with the presently available sample rates of digital control systems (higher sample rates are required). In addition, this form of direct torque control is not suitable for the addition of a high-frequency carrier signal necessary for the "self-sensing" (sensorless) position estimation technique. This technique enables low- and zero-speed position sensorless operation of the machine. Sensorless operation is desirable to reduce the number of necessary feedback signals and transducers, thus improving the reliability and reducing the mass and volume of the system. This research was directed at developing an alternative form of direct torque control known as a "deadbeat," or inverse model, solution. This form uses pulse-width modulation of the voltage applied to the machine, thus reducing the necessary sample and switching frequency for the high-speed NASA motor. In addition, the structure of the deadbeat form allows the addition of the high-frequency carrier signal so that low- and zero-speed sensorless operation is possible. The new deadbeat solution is based on using the stator and rotor flux as state variables. This choice of state variables leads to a simple graphical representation of the solution as the intersection of a constant torque line with a constant stator flux circle. Previous solutions have been expressed only in complex mathematical terms without a method to clearly visualize the solution. The graphical technique allows a more insightful understanding of the operation of the machine under various conditions.

Kenny, Barbara H.↗

An Overview of the Hybrid Illinois Device for Research and Applications Material Analysis Test-stand (HIDRA-MAT)

The Hybrid Illinois Device for Research and Applications (HIDRA) at the University of Illinois at Urbana-Champaign is a toroidal plasma device that enables fusion plasma-material interaction testing with both stellarator and tokamak plasmas. HIDRA’s long-pulse steady state stellarator plasmas provide a testbed for plasma facing component (PFC) plasma exposures. The HIDRA Material Analysis Test-stand (HIDRA-MAT) is a material characterization module attached to HIDRA that is being designed and fabricated to include thermal desorption spectroscopy and laser induced breakdown spectroscopy systems for in-vacuo PFC characterization. A specialized rotatable sample holder positions the sample for liquid metal droplet application from a liquid metal droplet injector on HIDRA-MAT. Early experiments look to investigate the effect liquid lithium has on porous tungsten samples’ retention of H, D, and He after plasma exposure. Preliminary results from a dual residual gas analyzer system show the ability to differentiate D2 and He in HIDRA-MAT. Finally, this work aims to advance the understanding of liquid metal PFCs and further the design and development of new fusion PFCs and technologies.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Probing the ultrafast gain and refractive index dynamics of a VECSEL

Typically, strong gain saturation and gain dynamics play a crucial role in semiconductor laser mode-locking. While there have been several investigations of the ultrafast gain dynamics in vertical-external-cavity surface-emitting lasers (VECSELs), little is known about the associated refractive index changes. Yet, such refractive index changes do not only have a profound impact on the pulse formation process leading to self-phase modulation, which needs to be compensated by dispersion, but they are also of particular relevance for assessing the feasibility of Kerr-lens mode-locking of VECSELs. Here, we measure both refractive index as well as gain dynamics of a VECSEL chip using the ultrafast beam deflection method. We find that, in contrast to the gain dynamics, the refractive index dynamics is dominated by an instantaneous (100 fs) and a very slow component (100 ps). The time-resolved measurement of nonlinear refraction allows us to predict a pulse-length dependent, effective nonlinear refractive index n 2,eff , which is shown to be negative and on the order of 10 -16 m 2 =W for short pulse lengths (100 fs). It becomes positive for large excitation fluences and large pulse lengths (few ps). These results agree with some previous reports of self-mode-locked VECSELs for which the cavity design and pulse properties determine sign and strength of the nonlinear refractive index when assuming Kerr-lens mode-locking.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

TH-AB-201-12: Using Machine Log-Files for Treatment Planning and Delivery QA

Purpose: To determine the segment reduction and dose resolution necessary for machine log-files to effectively replace current phantom-based patient-specific quality assurance, while minimizing computational cost. Methods: Elekta’s Log File Convertor R3.2 records linac delivery parameters (dose rate, gantry angle, leaf position) every 40ms. Five VMAT plans [4 H&N, 1 Pulsed Brain] comprised of 2 arcs each were delivered on the ArcCHECK phantom. Log-files were reconstructed in Pinnacle on the phantom geometry using 1/2/3/4° control point spacing and 2/3/4mm dose grid resolution. Reconstruction effectiveness was quantified by comparing 2%/2mm gamma passing rates of the original and log-file plans. Modulation complexity scores (MCS) were calculated for each beam to correlate reconstruction accuracy and beam modulation. Percent error in absolute dose for each plan-pair combination (log-file vs. ArcCHECK, original vs. ArcCHECK, log-file vs. original) was calculated for each arc and every diode greater than 10% of the maximum measured dose (per beam). Comparing standard deviations of the three plan-pair distributions, relative noise of the ArcCHECK and log-file systems was elucidated. Results: The original plans exhibit a mean passing rate of 95.1±1.3%. The eight more modulated H&N arcs [MCS=0.088±0.014] and two less modulated brain arcs [MCS=0.291±0.004] yielded log-file pass rates most similar to the original plan when using 1°/2mm [0.05%±1.3% lower] and 2°/3mm [0.35±0.64% higher] log-file reconstructions respectively. Log-file and original plans displayed percent diode dose errors 4.29±6.27% and 3.61±6.57% higher than measurement. Excluding the phantom eliminates diode miscalibration and setup errors; log-file dose errors were 0.72±3.06% higher than the original plans – significantly less noisy. Conclusion: For log-file reconstructed VMAT arcs, 1° control point spacing and 2mm dose resolution is recommended, however, less modulated arcs may allow less stringent reconstructions. Following the aforementioned reconstruction recommendations, the log-file technique is capable of detecting delivery errors with equivalent accuracy and less noise than ArcCHECK QA. I am funded by an Elekta Research Grant.

60 APPLIED LIFE SCIENCES↗

Coherent Processing of Up/Down Linear Frequency Modulated Chirps

A useful and popular waveform for high-performance radar systems is the Linear Frequency Modulated (LFM) chirp. The chirp may have a positive frequency slope with time (up-chirp) or a negative frequency slope with time (down-chirp). There is no inherent advantage to one with respect to the other, except that the receiver needs to be matched to the proper waveform. However, if up-chirps and down-chirps are employed on different pulses in the same Coherent Processing Interval (CPI), then care must be taken to maintain coherence in the range-compressed echo signals. We present the mathematics for doing so, for both correlation processing and stretch processing.

47 OTHER INSTRUMENTATION↗

Risk Factors for Pelvic Insufficiency Fractures in Locally Advanced Cervical Cancer Following Intensity Modulated Radiation Therapy

Purpose: To investigate the incidence of and risk factors for pelvic insufficiency fracture (PIF) after definitive chemoradiation therapy for locally advanced cervical cancer (LACC). Methods and Materials: We analyzed 101 patients with LACC treated from 2008-2014. Patients received weekly cisplatin and underwent external beam radiation therapy with 45 Gy in 25 fractions (node-negative patients) or 50 Gy in 25 fractions with a simultaneous integrated boost of 60 Gy in 30 fractions (node-positive patients). Pulsed dose rate magnetic resonance imaging guided adaptive brachytherapy was given in addition. Follow-up magnetic resonance imaging was performed routinely at 3 and 12 months after the end of treatment or based on clinical indication. PIF was defined as a fracture line with or without sclerotic changes in the pelvic bones. D{sub 50%} and V{sub 55Gy} were calculated for the os sacrum and jointly for the os ileum and pubis. Patient- and treatment-related factors including dose were analyzed for correlation with PIF. Results: The median follow-up period was 25 months. The median age was 50 years. In 20 patients (20%), a median of 2 PIFs (range, 1-3 PIFs) were diagnosed; half were asymptomatic. The majority of the fractures were located in the sacrum (77%). Age was a significant risk factor (P<.001), and the incidence of PIF was 4% and 37% in patients aged ≤50 years and patients aged >50 years, respectively. Sacrum D{sub 50%} was a significant risk factor in patients aged >50 years (P=.04), whereas V{sub 55Gy} of the sacrum and V{sub 55Gy} of the pelvic bones were insignificant (P=.33 and P=.18, respectively). A dose-effect curve for sacrum D{sub 50%} in patients aged >50 years showed that reduction of sacrum D{sub 50%} from 40 Gy{sub EQD2} to 35 Gy{sub EQD2} reduces PIF risk from 45% to 22%. Conclusions: PIF is common after treatment of LACC and is mainly seen in patients aged >50 years. Our data indicate that PIFs are not related to lymph node boosts but rather to dose and volume associated with irradiation of the elective pelvic target. Reducing the prescribed elective dose from 50 to 45 Gy may reduce the risk of PIF considerably.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Panoramic attitude sensor for Radio Astronomy Explorer B

An instrument system to acquire attitude determination data for the RAE-B spacecraft was designed and built. The system consists of an electronics module and two optical scanner heads. Each scanner head has an optical scanner with a field of view of 0.7 degrees diameter which scans the sky and measures the position of the moon, earth and sun relative to the spacecraft. This scanning is accomplished in either of two modes. When the spacecraft is spinning, the scanner operates in spherical mode, with the spacecraft spin providing the slow sweep of lattitude to scan the entire sky. After the spacecraft is placed in lunar orbit and despun, the scanner will operate in planar mode, advancing at a rate of 5.12 seconds per revolution in a fixed plane parallel to the spacecraft Z axis. This scan will cross and measure the moon horizons with every revolution. Each scanner head also has a sun slit which is aligned parallel to the spin axis of the spacecraft and which provides a sun pulse each revolution of the spacecraft. The electronics module provides the command and control, data processing and housekeeping functions.

Thomsen, R.↗

Speculation on a Solar Chronometer for Climate

Solar activity has been correlated to climatic fluctuations and has been postulated as a major factor in quasi-periodic global climatic change. However, correlations are not explanations of physical mechanisms and do not couple cause with effect. A mechanism for a chronometer for solar output variability is proposed based on relations between properties of thermonuclear fusion, nuclear magnetic moment, and nuclear magnetic resonance. A fundamental oscillation of a nucleus with a net nuclear magnetic moment (NMM) is the precession of its axis of rotation when subjected to a magnetic field. Nuclear magnetic resonance (NMR) is the preferred frequency of precession for a nucleus of a particular isotope when placed in a magnetic field of specific intensity. The NMM for those isotopes involved in the proton-proton (p-p) chain pathway for solar fusion varies from strong positive to strong negative. Individual fusion events, for hydrogen and helium isotopes which release varying amounts of energy, may be controlled by NMR frequencies. The pulses of energy from fusion events occurring at NMR frequencies in the solar interior may be transformed into pressure or gravity waves that emerge as gravity or acoustic waves at the surface. Dictated by spherical harmonics, certain wavelengths may be reinforced and reenter the solar interior to modulate the fusion process. Qualitative analysis of solar and climatic data support the interaction of the three basic components of the chronometer, magnetic activity, oscillation frequency, and solar energy output.

Perry, Charles A.↗

Phase transitions and hydrogen bonding in deuterated calcium hydroxide: High-pressure and high-temperature neutron diffraction measurements

In situ neutron diffraction measurements combined with the pulsed neutron source at the Japan Proton Accelerator Research Complex (J-PARC) were conducted on high-pressure polymorphs of deuterated portlandite (Ca(OD){sub 2}) using a Paris–Edinburgh cell and a multi-anvil press. The atomic positions including hydrogen for the unquenchable high-pressure phase at room temperature (phase II′) were first clarified. The bent hydrogen bonds under high pressure were consistent with results from Raman spectroscopy. The structure of the high-pressure and high-temperature phase (Phase II) was concordant with that observed previously by another group for a recovered sample. The observations elucidate the phase transition mechanism among the polymorphs, which involves the sliding of CaO polyhedral layers, position modulations of Ca atoms, and recombination of Ca–O bonds accompanied by the reorientation of hydrogen to form more stable hydrogen bonds. - Graphical abstract: Crystal structures of high-pressure polymorphs of Ca(OD){sub 2}, (a) at room temperature (phase II′) and (b) at high temperature (phase II), were obtained from in situ neutron diffraction measurements. - Highlights: • We measured in situ neutron diffraction of high-pressure polymorphs of Ca(OD){sub 2}. • Hydrogen positions of the high-pressure phase are first determined. • The obtained hydrogen bonds reasonably explain Raman peaks of OH stretching modes. • A phase transition mechanism among the polymorphs is proposed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Elucidating Quintet-State Dynamics in Singlet Fission Oligomers and Polymers with Tetracene Pendants

To unlock the potential of molecular engineering for practical quantum sensing and computing, it is essential to create and control pure magnetic states in molecular systems. Singlet fission (SF) in organic materials offers a promising approach by generating pairs of triplet excited states from photoexcited singlets. Here, in this work, we investigate SF in a polymer with strategically positioned tetracene pendant groups along a polynorbornene backbone and its oligomeric counterparts, facilitating intrapolymer through-space coupling. Using continuous-wave and pulsed time-resolved electron paramagnetic resonance (EPR) spectroscopy, we elucidate the spin dynamics and identify key intermediates, including the quintet state, that emerge during SF. Our findings reveal that exciton translational motion along the pendant groups enhances the dissociation of triplet pairs, with oligomer length playing a critical role in modulating spin state interconversion and exciton transport. Our results provide key insights into the SF mechanism in polymeric materials and highlight the role of oligomer length in modulating spin state interconversion and exciton transport. This work advances our understanding of SF in polymers, paving the way for their application in quantum information science and energy conversion technologies.

Bindra, Jasleen K. [Argonne National Laboratory (A↗

Modification of modulated plasma plumes for the quasi-phase-matching of high-order harmonics in different spectral ranges

We demonstrate the technique allowing the fine tuning of the distance between the laser-produced plasma plumes on the surfaces of different materials, as well as the variation of the sizes of these plumes. The modification of plasma formations is based on the tilting of the multi-slit mask placed between the heating laser beam and target surface, as well as the positioning of this mask in the telescope placed on the path of heating radiation. The modulated plasma plumes with the sizes of single plume ranging between 0.1 and 1 mm were produced on the manganese and silver targets. Modification of the geometrical parameters of plasma plumes proved to be useful for the fine tuning of the quasi-phase-matched high-order harmonics generated in such structures during propagation of the ultrashort laser pulses. We show the enhancement of some groups of harmonics along the plateau range and the tuning of maximally enhanced harmonic by variable modulation of the plasma.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Illumination-induced modulation of conductivity and Gunn oscillation properties in epitaxial GaAs

In this work, we illuminate a gallium arsenide (GaAs) Gunn device and study the light-induced changes of Gunn oscillation properties. We observe that illumination leads to the modulation of the Gunn threshold voltage, the Gunn oscillation magnitude, and the coherency of Gunn oscillation, with the nature of the modulation being closely related to the position of illumination on the device. These effects are attributed to the generation of optically excited carriers, which results in the modulation of conductivity and the electric field profile along the device. The finite element method is used to simulate the change of the field profile of the Gunn device caused by illumination. We also report an unexpected phenomenon of Gunn oscillation property manipulation with an optical chopper. In addition, wavelength-dependent, power-dependent, and pulsed illumination measurements are performed to help with further understanding the observations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Very high-energy gamma ray astronomy

Recent results in ground-based very high-energy (less than 10 to the eleventh power eV) gamma-ray astronomy are reviewed. The various modes of the atmospheric Cerenkov technique are described, and the importance of cosmic ray rejection methods is stressed. The positive detections (at approximately less than 10 to the 12th power eV) of the Crab pulsar that suggest a very flat spectrum and time-variable pulse phase are discussed. Observations of other pulsars (particularly Vela) suggest that these features may be general. The steady flux upper limits for the Crab Nebula are thus reconsidered, and a new value of the implied (Compton-synchrotron) magnetic field in the Nebula is reported. Evidence that a 4.8-hour modulated effect was detected at E sub gamma is less than 10 to the 12th power eV from Cyg X-3 is strengthened in that the exact period originally proposed agrees well with a recent determination of the X-ray period. The southern sky observations are reviewed, and the significance of the detection of an active galaxy (NGC 5128) is considered for source models and future observations.

Grindlay, J. E.↗

Shock position sensor for supersonic inlets

Static pressure taps or ports are provided in the throat of a supersonic inlet, and signals indicative of the pressure at each of the ports is fed to respective comparators. Means are also provided for directing a signal indicative of the total throat pressure to the comparators. A periodic signal is superimposed on the total throat pressure so that the signal from the static pressure tabs is compared to a varying scan signal rather than to total throat pressure only. This type of comparison causes each comparator to provide a pulse width modulated output which may vary from 0% 'time on' to 100% 'time on'. The pulse width modulated outputs of the comparators are summed, filtered, and directed to a controller which operates a bypass valve such as a door whereby air is dumped from the inlet to prevent the shock wave from being expelled out the front.

Dustin, M. O.↗

Efficient generation and extreme compression of multidimensional solitary states in molecular gas-filled hollow-core fibers driven by picosecond Yb lasers

We present an in-depth study on the impact of spatiotemporal Raman enhancement in molecular gas-filled hollow-core fibers (HCFs), demonstrating the efficient generation and post-compression of multidimensional solitary states (MDSS). Through different experimental scenarios—employing large-core HCFs filled with molecular gases (N 2 and N 2 O) and driven by high energy, sub-picosecond and picosecond Fourier transform-limited ytterbium laser pulses—this work leverages multimode propagation and enhanced spatiotemporal interactions to achieve significant spectral broadening and asymmetric redshift, contrasting sharply with self-phase modulation. Our findings reveal that, beyond the regime of maximum nonadiabatic molecular alignment, spatiotemporal nonlinear enhancement primarily governs spectral broadening for input pulse durations up to 1 ps. The process shows limited sensitivity to input pulse duration and the two investigated molecular gases (N 2 and N 2 O), with only subtle differences in broadening arising from their distinct Raman spectroscopic properties. Furthermore, post-compression of MDSS was achieved in various cases. Notably, using 7 mJ, 1 ps laser pulses, we generated 22 fs pulses with a 47% energy conversion efficiency of the input pulse energy. These results position MDSS as a powerful platform for generating high-energy, ultrashort pulses with tunable wavelengths, offering a robust solution for applications such as high harmonic generation.

47 OTHER INSTRUMENTATION↗

Performance of High Voltage Bipolar Pulse Generator with Fast Push-Pull Solid-State Switch Modules

Four identical pulse generators (pulsers) provide fast beam deflection in the Low Energy Beam Transport (LEBT) beam chopping system at the Spallation Neutron Source (SNS) Linac. The existing pulsers have become obsolete and need to be replaced to improve overall performance of the chopper system. A new bipolar pulse generator has been designed, and a prototype has been built and tested at the SNS. The generator uses fast push-pull transistor BEHLKE switch modules. It can produce a 1MHz burst of alternate 2.5kV with adjustable pulse widths during the 1-ms macro-pulse at a burst repetition frequency of 60Hz with rise/fall times of less than 40ns into a 100pF capacitive load. The performance enhancements of this new pulser in comparison with existing and previous versions of the pulse generator are discussed in the paper. The pulser can be used in applications requiring a series of bipolar ±3.5kV pulses, or unipolar pulses of positive or negative polarity with amplitude up to 4.5kV and various pulse widths with a minimum of 150ns. The maximum switching frequency, number of pulses, or burst repetition frequency in burst mode is limited by maximum power dissipation in the switches and other components. The features of this new pulser along with the results of timing control adjustments, timing and temperature measurements, and HV full power testing on the test stand are presented.

Peplov, Vladimir↗

Nonlinear regenerative amplification using tunable intracavity cascaded quadratic nonlinearities

Conventional nonlinear regenerative amplification utilizes Kerr (i.e., self-focusing) nonlinearity to broaden the spectrum via self-phase modulation during the direct amplification of ultrashort pulses, which helps overcome spectral gain narrowing for high-energy, ultrashort-pulse generation. We introduce cascaded quadratic nonlinearities from a type-I second-harmonic generation crystal, which can be tuned in both magnitude and sign via the phase-mismatching condition, inside a regenerative amplifier to enable nonlinearity-tunable regenerative amplification. We demonstrate, both experimentally and numerically, a nonlinear Yb:YAG thin-disk regenerative amplifier with either positive or negative net nonlinearity that delivers 1-kHz, >0.4-mJ pulses as short as ∼200 fs and high-quality beams free of self-focusing. The laser’s average power can be scaled to >100 W when seeded and operated at a much higher repetition rate to benefit various applications.

47 OTHER INSTRUMENTATION↗