Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “polycarbonates”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Analysis of Cosmic Spherule Candidates from the Kwajalein Micrometeorite Collection

The Kwajalein micrometeorite collection utilised high volume air samplers fitted with 5 micrometer laser-etched polycarbonate membrane filters to capture particles directly from the atmosphere. The filters were changed weekly over several months throughout 2011/12, providing the opportunity to investigate the contemporary flux of micrometeorites. We recently reported the results of our initial survey of cosmic spherule-like particles on several of these filters. We identified three main groups of particle based on bulk compositions: 1. Silicate spherules rich in Mg, Ca and Fe, 2. Silicate spherules rich in Al, Ca, K and/or Na and 3. Fe-rich spherules. Abundances appeared to change over time suggesting links with celestial activity (e.g. meteor showers), however, spherules similar to groups 2 and 3 can be produced by terrestrial and anthropogenic activity (e.g. volcanic microspherules exhibit similar compositions to group 2 spherules and metallic spherules similar to those of group 3 can be formed during fuel combustion). We are now studying the internal structures and chemistries of these spherules and comparing against cosmic spherules identified in other collections to confrim their origins and further contrain the contemporary micrometeorite flux. Particles are being picked, embedded in resin and polished through to reveal their interiors. Here we will describe our ongoing analyses of these particles via SEM. We will also introduce our new collection using this method that is currently being performed in the Antarctic.

Wozniakiewicz, P. J.↗

Kennedy Space Center Fixation Tube (KFT)

Experiments performed on the International Space Station (ISS) frequently require the experimental organisms to be preserved until they can be returned to earth for analysis in the appropriate laboratory facility. The Kennedy Fixation Tube (KFT) was developed to allow astronauts to apply fixative, chemical compounds that are often toxic, to biological samples without the use of a glovebox while maintaining three levels of containment (Fig. 1). KFTs have been used over 200 times on-orbit with no leaks of chemical fixative. The KFT is composed of the following elements: a polycarbonate main tube where the fixative is loaded preflight, the sample tube where the plant or other biological specimens is placed during operations, the expansion plug, actuator, and base plug that provides fixative containment (Fig. 2). The main tube is pre-filled with 25 mL of fixative solution prior to flight. When actuated, the specimen contained within the sample tube is immersed with approximately 22 mL (+/- 2 mL) of the fixative solution. The KFT has been demonstrated to maintain its containment at ambient temperatures, 4degC refrigeration and -100 C freezing conditions.

Space Center↗

Ultraviolet Testing of Space Suit Materials for Mars

Human missions to Mars may require radical changes in the approach to extra-vehicular (EVA) suit design. A major challenge is the balance of building a suit robust enough to complete multiple EVAs under intense ultraviolet (UV) light exposure without losing mechanical strength or compromising the suit's mobility. To study how the materials degrade on Mars in-situ, the Jet Propulsion Laboratory (JPL) invited the Advanced Space Suit team at NASA's Johnson Space Center (JSC) to place space suit materials on the Scanning Habitable Environments with Raman & Luminescence for Organics and Chemicals (SHERLOC) instrument's calibration target of the Mars 2020 rover. In order to select materials for the rover and understand the effects from Mars equivalent UV exposure, JSC conducted ground testing on both current and new space suit materials when exposed to 2500 hours of Mars mission equivalent UV. To complete this testing, JSC partnered with NASA's Marshall Space Flight Center to utilize their UV vacuum chambers. Materials tested were Orthofabric, polycarbonate, Teflon, Dacron, Vectran, spectra, bladder, nGimat coated Teflon, and nGimat coated Orthofabric. All samples were measured for mass, tensile strength, and chemical composition before and after radiation. Mass loss was insignificant (less than 0.5%) among the materials. Most materials loss tensile strength after radiation and became more brittle with a loss of elongation. Changes in chemical composition were seen in all radiated materials through Spectral Analysis. Results from this testing helped select the materials that will fly on the Mars 2020 rover. In addition, JSC can use this data to create a correlation to the chemical changes after radiation-which is what the rover will send back while on Mars-to the mechanical changes, such as tensile strength.

Larson, Kristine↗

Ultraviolet Testing of Space Suit Materials for Mars

Human missions to Mars may require radical changes in the approach to extra-vehicular (EVA) suit design. A major challenge is the balance of building a suit robust enough to complete multiple EVAs under intense ultraviolet (UV) light exposure without losing mechanical strength or compromising the suit's mobility. To study how the materials degrade on Mars in-situ, the Jet Propulsion Laboratory (JPL) invited the Advanced Space Suit team at NASA's Johnson Space Center (JSC) to place space suit materials on the Scanning Habitable Environments with Raman & Luminescence for Organics and Chemicals (SHERLOC) instrument's calibration target of the Mars 2020 rover. In order to select materials for the rover and understand the effects from Mars equivalent UV exposure, JSC conducted ground testing on both current and new space suit materials when exposed to 2500 hours of Mars mission equivalent UV. To complete this testing, JSC partnered with NASA's Marshall Space Flight Center to utilize their UV vacuum chambers. Materials tested were Orthofabric, polycarbonate, Teflon, Dacron, Vectran, spectra, bladder, nGimat coated Teflon, and nGimat coated Orthofabric. All samples were measured for mass, tensile strength, and chemical composition before and after radiation. Mass loss was insignificant (less than 0.5%) among the materials. Most materials loss tensile strength after radiation and became more brittle with a loss of elongation. Changes in chemical composition were seen in all radiated materials through Spectral Analysis. Results from this testing helped select the materials that will fly on the Mars 2020 rover. In addition, JSC can use this data to create a correlation to the chemical changes after radiation-which is what the rover will send back while on Mars-to the mechanical changes, such as tensile strength.

Larson, Kristine↗

Enabling Experimental Evolution: Multi-Parameter Sensor System Integration into a Culture/Stressor Biofluidics System

Experimental evolution (EE) exposes microbial communities to ecological stressors, simulating dynamics up to near-extinction events. Combined with comparative sequencing and other molecular tools, such data can inform the genetic and other biological mechanisms underlying extremophile adaptation, and other observed effects. Automating this type of experiment using biofluidics can mitigate many traditional obstacles, including delays in assay results and environment adjustment and the need for many replicates. A first-generation device for automating EE procedures, the Automated Adaptive Directed Evolution Chamber (AADEC), was developed at NASA Ames. UV-C radiation was the stressor, an LED-photodiode array measured optical density, magnetic agitation and peristaltic pump systems ensured nutrient availability, and Arduino microcontrollers provided control. Escherichia coli in LB kanamycin media was used for testing and performance verification. A manual laboratory procedure with timed exposure to UV-C was performed to typify tolerance acquisition. Approximately a 106 factor increase in survival ratio was recorded over multiple iterations. Currently, a second-generation device is being developed integrating more real-time sensors: redox potential (ORP), indicating available/consumed metabolic energy; dissolved oxygen (DO), indicating aerobic/anaerobic growth; pH, indicating metabolic products; and electrical conductivity (EC), another indicator of metabolic products. The EC sensor system was constructed and calibrated in-house and matched commercial sensors in the required range. A Raspberry Pi computer automated the electrical system, allowing real-time data acquisition. The fluidics card was made of CNC-milled polycarbonate for biocompatibility. Each sensor parameter can also be used as a selection pressure alone or in combination with others to create extreme microbial environments. As a proof of concept, this work demonstrated sensor operation in one pair of growth-sensor chambers. It can be expanded to a multi-chamber system to enable inter-culture comparisons and multi-population studies. The prior Arduino system will be ported to the RPi system. Future stressors to be added include thermal, reactive oxygen species, and varying nutrient availability.

Govinda Raj, Chinmayee↗

Molecular Dynamics of ULTEM 9085 for 3D Manufacturing: Spectra, Thermodynamic Properties, and Shear Viscosity.

We present results of a molecular dynamic analysis of welding at the polymer-polymer interface. The analysis is performed for polyetherimide/ polycarbonate polymer blends. The work is motivated by the applications to 3D manufacturing in space. In the first part of the report, we discuss bulk and spectral characteristics of the amorphous polymer blends. The vibrational and infra-red spectra obtained using auto-correlation functions calculations in molecular dynamics are compared with the experimental spectra. The mechanical and thermal properties of the samples including heat capacity, bulk modulus, and thermal expansion coefficients are estimated and compared with experimental values. In the second part of the report, we discuss the result of molecular dynamical modeling of shear viscosity in a fully atomistic model of amorphous polymer blends with flat interface. The key result of the research is the demonstration of shear thinning behavior of the shear viscosity as a function of shear rate which is in good agreement with experimental data.

Luchinsky, Dmitry G.↗

Characterization of Biological Fallout Particles of Cleanrooms to Measure Spacecraft Cleanliness

NASA cleanrooms are humidity, temperature-regulated, and particle contaminant-controlled environments used for spacecraft assembly. Microorganisms, which are crucial contaminants shed from humans and transported through the environment, can adapt to the oligotrophic cleanroom conditions. These biogenic particles need to be identified to extend our knowledge of biological contamination for future NASA mission use. Here, we devised an aluminum coupon with polycarbonate filter setup to collect fallout particles from an ISO 5 and an ISO 7 cleanroom. We demonstrated the presence of microbial particles, as standalone entities and associated with inert particles in cleanroom environments. The contamination was confirmed as biogenic in virtue of estimating the elemental composition of individual and aggregated particles using an epifluorescence and Field Emission Scanning Electron Microscopy (FESEM) coupled with an energy dispersive X-ray analysis (EDX). Epifluorescence microscopy showed that the particles were stained less (25%) with SYTO 9 and more (75%) with propidium iodide, suggesting that the suspected biogenic particles are membrane-compromised. Remarkably, biological particles such as bacteria and fungal spores/hyphae were observed at sizes ranging from 2 to 70 µm, with abundant C and O elemental signatures and essential tracers (Na, Mg, K, Ca and Cl). Inert particles (2 to 500 µm) that were characterized included compositions such as silica (SiO2), aluminosilicates (Al, Si), and carbonaceous fibers. Furthermore, we designed and illustrated a unique correlative epifluorescence and FE-SEM method to strengthen this approach by acquiring the same biogenic particles in the same filter coupon for a one-to-one comparison. Interestingly, the SYTO 9 stained particles showed abundant C and O elemental signature implying that they are viable microbial particles. Constant evaluation of cleanroom biological and inert particles will help to characterize biological contamination for future NASA missions (e.g. Mars 2020).

Malli Mohan, Ganesh Babu↗

Spacecraft Lighting to Mitigate Microbial Growth

In this innovation project, we investigated the usage of narrow band violet light (408 nm) to attenuate the growth of bacteria typically found on ISS. Violet light is less hazardous than UV light and it can transmit through plastics, such as clear acrylics, making it possible to incorporate into large surface lamps and acrylic or polycarbonate based optical light guides. This study built a custom LED surface panel that was edge lit by an array of 408 nm violet LEDS. The optical light guide technology used in the lamp and the 408 nm violet LEDs are available on the market from multiple vendors. The application of the concept of using violet light driven LED panels and optical light guides is to integrate the paneling into spacecraft architectural surfaces for the automation of a light based microbial countermeasure that could enhance current cleaning methods used in areas on spacecraft prone to microbial growth.

Clark, Toni A.↗

Electrical and Thermal Characterization of 3D Printed Thermoplastic Parts with Embedded Wires for High Current-Carrying Applications

Fabrication of parts exhibiting multi-functionality has recently been complemented by hybrid polymer extrusion additive manufacturing in combination with wire embedding technology. While much mechanical characterization has been performed on parts produced with fused deposition modeling, limited characterization has been performed when combined electrical and thermal loads are applied to 3D printed multi-material parts. As such, this work describes the design, fabrication, and testing of 3D printed thermoplastic coupons containing embedded copper wires that carried current. An automated fabrication process was used employing a hybrid additive manufacturing machine that dispensed polycarbonate thermoplastic and embedded bare copper wires. Testing included AC and DC hipot testing as well as thermal testing on as-fabricated and heat treated coupons to determine the effect of porosity in the substrate. The heat-treated parts contained reduced amounts of porosity, as corroborated through scanning electron microscopy, which led to 50 % increased breakdown strength and 30 to 40 % increased heat dissipation capabilities. The results of this research are describing a set of design protocol that can be used as a guideline for 3D printed embedded electronics to predict the electrical and thermal behavior.

Hipot testing↗

BioNutrients: Microbial on-demand production of short shelf-life micronutrients in space

Long duration deep space missions pose a significant challenge when considering adequate nutrition for human spaceflight. Many micronutrients supplied in pre-packaged foods for low Earth orbit flights have a short shelf life and will degrade over multi-year missions. One strategy to mitigate the risk of micronutrient malnutrition is to grow fresh foods to supplement a pre-packaged diet. The BioNutrients project aims to develop systems for growing edible microorganisms that are genetically engineered to produce short shelf life micronutrients. BioNutrients-1 (BN-1) is a five-year spaceflight project currently underway on the International Space Station (ISS) that tests long-term storage and production of two carotenoids, β-carotene and zeaxanthin, in genetically engineered yeast strains. BN-1 on-orbit and ground control activities indicate that the nutrient production system will be stable for at least two years in ambient storage conditions. BN-1 is also testing the effects of long-term ISS storage on viability and gene expression using “stasis packs” containing a series of microorganisms useful in food and biomanufacturing processes. Stasis pack analysis is distinguishing microorganisms with full viability after two years of storage from other species that lose viability rapidly. In parallel, BioNutrients-2 (BN-2) is being developed as a six-month flight experiment that will expand the range of foods produced on ISS to include yogurt, kefir, and probiotic yeast. BN-2 will improve upon hardware design by transitioning from a hard-shell polycarbonate bioreactor to a flexible fluorinated ethylene propylene (FEP) bag. This change reduces the mass and volume required to store production packs. The long-term goal of BioNutrients is to develop the capability for rapid and safe delivery of multiple micronutrients in single-use production packs. We expect synthetic biology approaches similar to BioNutrients will play an important role for astronaut health in future NASA missions to the Moon and Mars.

Synthetic Biology↗

Calibration and Validation of the SHERLOC Instrument Operating in Jezero Crater, Mars

The Scanning Habitable Environments with Raman and Luminescence for Organics and Chemistry (SHERLOC) is an instrument onboard the Mars 2020 Perseverance rover. It consists of a spectrometer that measures deep ultraviolet (DUV) resonance Raman and native fluorescence photons generated through surface interactions with a 248.6 nm pulsed laser. Two microscopic imagers, the Autofocus Context Imager (ACI) and the Wide-Angle Topographic Sensor for Operations and eNgineering (WATSON), provide high-resolution context images of SHERLOC targets. The ACI is co-boresighted with the spectrometer. To ensure proper calibration, the SHERLOC calibration target (SCT) is mounted on the front of the rover and consists of ten different materials. The SCT was designed, fabricated, assembled, and tested by Jacobs Technology, Inc., and NASA Johnson Space Center. The dimensions of the calibration target housing are 150 x 89 x 33 mm and it weighs ~437 g. The ten targets are arranged in two rows; the first six are hard targets (AlGaN for Raman and fluorescence, diffuse transmission target, a slice of the SaU008 Mars meteorite, an intensity maze, and polycarbonate over geocache coin) and the remaining four are soft-goods targets (Vectran, Ortho-Fabric, Teflon, and nGimat-coated Teflon). The hard targets calibrate the spectrometer’s Raman and fluorescence spectral accuracy, ambient light reflection, and Raman response curve, while the soft-goods targets are spacesuit materials that function as human exploration targets, some of which are also used for spectral calibration. SHERLOC also has an internal calibration target consisting of AlGaN on sapphire (275 nm) located inside the ACI opaque dust cover to ensure proper instrument functioning between calibration target analyses. Initial SHERLOC, ACI, and WATSON calibration and validation on Mars was performed using the internal calibration target on sols 59, 83, 98, and 141; WATSON imaging of the SCT on sols 26 and 62, and SHERLOC spectroscopy and ACI imaging of the SCT on sol 59. These early data provide initial insights into instrument performance and the stability and degradation of the calibration target materials relative to the Martian surface and dust environment. Early observations also have implications for future astronaut spacesuit materials.

Trevor G Graff↗

Remodeling BioSentinel’s Microbial Metabolism Measurement System

BioSentinel, the first biological CubeSat beyond low Earth orbit, will investigate how Saccharomyces cerevisiae responds to ionizing radiation using optical measurements of a colorimetric metabolic indicator dye (alamarBlue). To map optical data to more detailed metabolic measurements, a microbial culture system for ground testing was designed consisting of a 400 mL beaker and a rubber stopper with pass-through holes for its five sensor probes (electrical conductivity, pH, oxidation-reduction potential, dissolved oxygen, optical density). The initial design had several drawbacks. It was only partially reusable due to its one-time sealants: Teflon tape and parafilm. A steady increase in oxygen levels within the sensor’s testingdata indicated the design was not sufficiently airtight. Degradation of the rubber stopper’s elasticity due to sterilization and reinsertion of the probes led to poor robustness and eventual replacement. The vessel’s large headspace didn’t reproduce flight conditions and a large culture volume required more reagents. The system has been redesigned to contain a rigid, biocompatible polycarbonate disc lid that allows for threaded inserts. The culture vessel’s height will be reduced from 110 mm to 65 mm to decrease overhead space and material costs. A more reliable seal will be achieved with a gasket and clamps. The optical probe records absorbance at four wavelengths to characterize cell density and alamarBlue dye ratios. A pneumatically operated plunger draws media through the hollow interior of the probe. Currently, deformation of the silicone on the plunger causes asymmetrical movement and a drift from its initial state. Designs are being developed to limit the plunger’s travel for a more accurate measurement cycle. The remodeled system is under construction and will be tested for leaks and accuracy. The measurements collected will be used to provide additional insight into the optical data returned from the BioSentinel mission.

Astrobiology↗

Exploration Helmet Permanent Anti-fog Study

For the current Extravehicular Mobility Unit (EMU) spacesuit, an astronaut applies an anti-fog solution to the interior of the helmet bubble before each EVA. However, the anti-fog solution has been reported to cause eye discomfort during at least seven EMU EVAs when the anti-fog solution contacted the crew member’s eyes. During STS-100, astronaut Chris Hadfield reported the eye irritation temporarily blinded him during his spacewalk. In addition, the wipe on anti-fog solution is a consumable that needs to be accounted for and a supply launched for missions. To solve this, the Exploration EMU (xEMU) pressure bubble investigated using a permanent anti-fog coating during Design Verification and Test (DVT) human in the loop (HITL) events. Chosen for previous use in Constellation Space Suit develop, HTAF-601, a water based permanent anti-fog solution, was tested. However, major issues have arisen with further HITL testing with the coating. Cleaning the helmet has been a challenge to avoid damaging the permanent anti-fog coating. NASA has completed a set of different methods for cleaning the anti-fog to try to document a preferred method. It was found isopropyl alcohol (IPA) cannot be used to clean the interior of the helmet because it will strip and delaminate the permanent anti-fog coating. Even with using a very gentle cleaning method of flushing with distilled or DI water and dabbing at facial oils, the permanent anti-fog starts to delaminate consistently after 50 hours manned pressurized time (MPT). Finally, the HTAF-601 coating is being discontinued by the vendor. Due to these issues, further investigation is being completed evaluating two solvent based anti-fog solutions: Exxene’s HCF-100 and FSI’s Visgard 106-94. Each coating will be evaluated on polycarbonate samples for application consistency, steam cycles (mimicking breath cycles), cleaning durability, haze, and light transmission. This study will determine if either coating is a viable option to pursue as a permanent anti-fog for spacesuit helmet applications.

spacesuit↗

Evaluation of Long Term Microbial Regrowth in Slosh Water Tanks From the International Space Station

The NASA Launch Services Program (LSP) maintained the SPHERES-Slosh experiment aboard the International Space Station (ISS) between 2013 and 2019. The purpose of the Slosh experiment was to examine how liquids move inside fuel tanks in a microgravity environment. These tanks were similar to water storage tanks planned for use aboard future space systems, where large dormant periods between crew-use will provide similar conditions for biological growth or chemical leaching. The water within the SLOSH tanks remained undisturbed for over five years after testing concluded, providing a unique sample for stored water under microgravity conditions without prior protocols for microbial control such as sterilization or addition of biocides. The Slosh storage tanks were returned to Kennedy Space Center (KSC) aboard SpaceX CRS-18 mission in November 2019. Upon return of the tanks, the water within each tank was analyzed to determine how the water chemistry and biology changed during its tenure in microgravity. The data obtained and described within this publication provided a basis and reasoning for planning water storage and purification treatment methods aboard ISS, Gateway, and future space habitats. Results demonstrated that low microbial concentrations were present within the water, as expected since no biocide treatment was employed, yet no extensive biofilm formation was observed after 5 years even in the presence of microbial food sources such as the polycarbonate structure and food color additives. This experimentation demonstrates that future biofilm studies should be performed on this type of experimental setup with proper controls aboard ISS to examine microbial regrowth to improve microbial control within space water systems.

Luke B. Roberson↗

Exploration Helmet Permanent Anti-Fog Study

For the current Extravehicular Mobility Unit (EMU) spacesuit, an astronaut applies an antifog solution to the interior of the helmet bubble before each EVA. However, the anti-fog solution has been reported to cause eye discomfort during at least seven EMU EVAs when the anti-fog solution contacted the crew member’s eyes. During STS-100, astronaut Chris Hadfield reported the eye irritation temporarily blinded him during his spacewalk. In addition, the wipe on anti-fog solution is a consumable that needs to be accounted for and a supply launched for missions. To solve this, NASA has tested different permanent anti-fog coatings. However, major issues have arisen with Human in the Loop (HITL) testing with the coatings. Cleaning and removing Valsalva devices which use pressure sensitive adhesives have been challenges to avoid damaging the permanent anti-fog coating. Due to these issues, further investigation is being completed evaluating two solvent based anti-fog solutions: Exxene’s HCF-100 and FSI’s Visgard 106-94. Each coating will be evaluated on polycarbonate samples for application consistency, steam cycles (mimicking breath cycles), cleaning durability, haze, and light transmission. This study will determine if either coating is a viable option to pursue as a permanent anti-fog for spacesuit helmet applications.

spacesuit↗

Effect of Roughness on Transition on the BOLT-1a Geometry in Supersonic Flow

Infrared thermography measurements on an 8.8% scale BOLT-1a model were made in the NASA Langley Probe Calibration Tunnel for freestream unit Reynolds numbers from 7.7 × 10^ -6 /m to 30.7 × 10^ -6 /m, a freestream Mach number of 3.5, and nominal angle of attack of 0 degrees. The model was printed from polycarbonate and tested before and after fine-grit sanding to evaluate the effect of surface roughness on transition. Global surface roughness measurements were obtained using a 3D optical profilometer. The temperature distributions on the upper and lower experimental surfaces of the test article were simultaneously captured using two infrared cameras. Prior to testing, the facility’s freestream environment was characterized. At a freestream unit Reynolds number of approximately 17 × 10^ -6 /m, the nozzle-wall boundary layer began to transition non-uniformly, inducing transition on the model. The boundary-layer state was determined by analyzing Stanton number distributions computed from the surface temperature measurements. The present supersonic conditions that were examined on BOLT-1a were found to display both similarities and disparities in comparison to previous hypersonic experiments.

boundary layer transition↗

Space Environmental Effects on Additively Manufactured Materials – Results from MISSE-9 and MISSE-10

The NASA Marshall Space Flight Center (MSFC) Space Environmental Effects (SEE) and Contamination Control (CC) teams prepared and characterized MISSE-9 and MISSE-10’s additively manufactured (AM) materials samples to investigate the effect of ultraviolet (UV) radiation, thermal cycling, outgassing, and temperature and provide data on the durability of these samples. Materials studied were polyetherimide (Ultem 1010 and 9085), electrostatic dissipative polyetherketoneketone (ESD-PEKK), also known commercially as Antero 840CN03, polycarbonate biocompatible per ISO 10993 USP Class VI (PC-ISO), and Inconel 718. Some samples were manufactured at MSFC, while 3D printer manufacturers Stratasys and Made In Space, Inc. (MIS) (now Redwire) participated in this effort to compare different vendors and printing setups. Results from nondestructive analyses and tensile testing are presented.

additive manufacturing↗

Exploration Helmet Permanent Anti-Fog Study

For the current Extravehicular Mobility Unit (EMU) spacesuit, an astronaut applies an antifog solution to the interior of the helmet bubble before each EVA. However, the anti-fog solution has been reported to cause eye discomfort during at least seven EMU EVAs when the anti-fog solution contacted the crew member’s eyes. During STS-100, astronaut Chris Hadfield reported the eye irritation temporarily blinded him during his spacewalk. In addition, the wipe on anti-fog solution is a consumable that needs to be accounted for and a supply launched for missions. To solve this, NASA has tested different permanent anti-fog coatings. However, major issues have arisen with Human in the Loop (HITL) testing with the coatings. Cleaning and removing Valsalva devices which use pressure sensitive adhesives have been challenges to avoid damaging the permanent anti-fog coating. Due to these issues, further investigation is being completed evaluating two solvent based anti-fog solutions: Exxene’s HCF-100 and FSI’s Visgard 106-94. Each coating will be evaluated on polycarbonate samples for application consistency, steam cycles (mimicking breath cycles), cleaning durability, haze, and light transmission. This study will determine if either coating is a viable option to pursue as a permanent anti-fog for spacesuit helmet applications.

spacesuit↗