Bunch Length Measurements at the CEBAF Injector at 130 kV

In this work, we investigated the evolution in bunch length of beams through the CEBAF injector for 8?770 fC charge per bunch. Using the software General Particle Tracer (GPT), we have simulated beams through the beamline of the CEBAF injector to predict bunch lengths at the location of a beam chopper for comparison with measurements and to validate the model. We performed these simulations with the existing injector using a 130 kV gun voltage. The mea- surements have been done using chopper phase scanning technique for two injector laser drive frequencies 499 MHz and 249.5 MHz. Acknowledgement This material is based upon work supported by the U.S. Department of Energy, Office of Science, Office of Nuclear Physics under contract DE-AC05-06OR23177.

Pokharel, S.↗

Energy Services Interface: Architecture, Requirements, and Agreements

This report continues and extends the development of the Energy Services Interface (ESI) that recently has been led by the U.S. Department of Energy’s Grid Modernization Laboratory Consortium. The ESI is intended to facilitate the coordination of multiple, flexible energy resources that work in tandem to satisfy grid objectives by using performance attributes encoded within an ESI Service Template. The ESI relies on a pair of interfaces, representing the service requestor (the consumer of a service) and a service provider (who manages its resources per the agreed performance attributes) to achieve what is commonly known as a “grid service”. Due to its performance-driven approach, the ESI is hypothesized to be able to satisfy all common grid needs via only six common ESI service types. This report first reviews the status of ESI development, including its fundamental tenets. The report makes three important contributions to ESI development: First, it recognizes the similarity between service level agreements and the contract-like agreements that would be needed between energy service requestors and providers and recommends that ESI service agreements be modeled after the web services agreement specification. Second, whereas prior development efforts had focused on a flat, five-stage lifecycle, this report asserts that the ESI should have three behavioral layers in its architecture—the discovery, agreement, and service layers. Finally, this report offers concrete requirements that should be useful toward the development of the service requestors’ and service providers’ respective communications interfaces.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Small to Full Height Scale Comparisons of Cesium Ion Exchange Performance with Crystalline Silicotitanate

The U.S. Department of Energy’s (DOE) Hanford Site houses 56 million gallons of high-level radioactive waste generated from plutonium production from 1944 to 1988. The supernatant waste, currently stored in underground tanks, is intended to be vitrified following filtration and 137 Cs removal at the Hanford Waste Treatment and Immobilization Plant (WTP) Low-Activity Waste (LAW) Vitrification Facility. The WTP Pretreatment Facility will not be operational for several years. The Tank Side Cesium Removal (TSCR) system is a technology demonstration that will remove cesium from tank waste supernate to support directly feeding LAW to the vitrification facility. The 137 Cs removal is important to meet the WTP LAW contract specification and ultimately for creating a contact-handled waste form. The waste acceptance criteria (WAC) limit for the WTP LAW Facility is <3.18E-5 Ci 137 Cs per mole Na. The TSCR system is skid mounted and employs two key technologies: dead end filtration for solids removal and ion exchange (IX) for cesium removal. Filtration is necessary to protect the functionality of the IX columns. The IX process utilizes sodium form crystalline silicotitanate (CST) IX media produced by UOP Honeywell, LLC (Des Plaines, IL) under the product name IONSIV R9140-B, 18 x 50 mesh, in a lead-lag-polish column configuration. Each column contains a CST bed height of 92 inches and a volume of approximately 157 gallons of CST IX media. The full-scale TSCR operation will run at a residence time of 1.9 bed volumes (BV)/h, which results in a superficial velocity of 7.3 cm/min and a flowrate of ~5 gal/min. Column testing at small (2.5% of the full bed height), medium (12% of the full bed height), and full-height scales has been previously conducted to evaluate process variables and scale up performance of Cs exchange onto the CST. Cesium load performances from various sieve cuts at the small scale indicated that a 30-mesh sieve cut be tested to determine if it better reflects the 12% and full-height column performances at the small scale. Two process flowrates were tested in the small-column configuration with <30-mesh CST and simulant solutions. These tests were compared to full-height column tests at the same residence times to assess CST particle size effect on column scaling. Table S.1 summarizes the observed column performance determined for the two flowrates juxtaposed to the previous work with 5.6 M Na simulant at higher scales (used as benchmarks). The WAC breakthroughs between the small and full-height tests at 1.3 BV/h differed by ~59 BVs. The WAC breakthroughs for small, medium, and full-height tests at 1.8 BV/h were consistent at 240 BVs. The 50% Cs breakthroughs were nominally equivalent for all column tests. The common transition zones and onsets of Cs breakthrough at the 1.8 BV/h tests indicated that the Cs mass transfers were equivalent and thus the <30-mesh CST Cs load performance at the small scale successfully modeled that of the full-height system. It is recommended that the <30-mesh CST be used in subsequent 10-mL CST bed tests.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Nucleation Effects in the Atomic Layer Deposition of Nickel–Aluminum Oxide Thin Films

Atomic layer deposition (ALD) has become an important technique to synthesize a wide variety of materials on the subnanometer length scale. Expanding the library of ALD for ternary materials is vital for applications in which ternary materials allow for tuning of physical, optical, and electronic properties. In this work reported herein, we demonstrate the first report of nickel–aluminum oxide (Ni–Al–O) films deposited by ALD using nickeloceneozone and trimethylaluminum-water as reactants. While deposition of a wide range of compositions is achieved, the observed growth per cycle (GPC) did not follow the simple combination of GPCs measured for the binary ALD processes. Nucleation studies performed to better understand this behavior reveal that the deposition of aluminum oxide is greatly enhanced on a NiO surface prepared by nickelocene and ozone. A model is developed that considers nucleation effects to predict composition and thickness as a function of supercycle recipe. Characterization of the deposited films shows that Al-doping of NiO results in contraction of the NiO lattice, decreased crystallinity, and reduced density, and that films become completely amorphous at compositions with less than 50% Ni. In addition, Al-doped NiO films deposited by ALD are investigated as a hole-selective transport layer in lead-based perovskite solar cells. An Al doping of ~4% improves power conversion efficiency of the perovskite-based devices over that of NiO primarily through increases in fill factor.

36 MATERIALS SCIENCE↗

Analytical Tool to evaluate Heterogeneous Neuromorphic Architectures (ATHENA)

SAND2022-7062 O The Analytical Tool to Evaluate Heterogeneous Neuromorphic Architectures (ATHENA) quickly evaluates performance metrics like energy, area, and latency for an AI/ML network. It currently supports the evaluation of analog neural networks. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Hahn, Andrew↗

Useful python scripts

SAND2023-11904O This collection of original scripts is made up of Python, Makefile, and Vim. Each script performs a single commonly used function in an encapsulated manner that can easily integrate into larger application-specific software. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Penney, Keith↗

mvBayesPy

SAND2025-11476O The mvBayesPy tool is a Python package that performs multivariate Bayesian analysis on generic data. It includes tools for regression modeling, diagnosis, basis decomposition, sensitivity analysis and visualization. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Tucker, James [Sandia National Lab. (SNL-CA), Live↗

Probing the In Situ Pseudocapacitive Charge Storage in Ti 3 C 2 MXene Thin Films with X-ray Reflectivity

MXenes are a large family of two-dimensional materials that are attractive for energy storage due to their high-rate charging capabilities as well as for electrochemical actuators, water purification, and many other technologies. Ion intercalation during electrochemically driven charge and discharge processes is the fundamental process associated with MXene functionality, which we have characterized here using in situ and operando X-ray reflectivity (XRR). Experiments performed at the Advanced Photon Source at Argonne National Laboratory monitored the changes in the structure of a Ti 3 C 2 MXene film on a platinum current collector as a function of static applied potential between 0.3 and –0.7 V vs Ag/AgCl in an aqueous 0.1 M Li 2 SO 4 electrolyte. Negative potential sweeps lead to a contraction of 1.2 Å in the interlayer spacing and a loss of electron density between the layers, likely due to Li + ion insertion and water removal. The change in lattice spacing includes a continuous variation vs potential as well as an additional discrete contraction that occurs near –0.35 V that has the characteristics of a first-order transition. The continuous change in the MXene interlayer spacing is associated with the capacitive charge, while the discrete change in structure correlated to the weak feature in the cyclic voltammogram at –0.35 V can be interpreted as either a pseudocapacitive charging process or a potential-dependent change in capacity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

WEC as a multiport

SAND2025-00555O WEC as a multiport is a software tool that simplifies the modeling and design of ocean wave energy converters (WECs) using a multi-port network framework in the frequency domain. Users can simulate the dynamic interactions between WECs and ocean waves, optimizing energy extraction and system performance. This tool supports the analysis of complex wave energy systems, aiding in the development of efficient and effective WEC designs. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Coe, Ryan↗

New Improved Horizontal Electropolishing System for SRF Cavities

The best performance of niobium SRF accelerating cavities is obtained with surfaces smoothed with electropolishing chemical finishing. Jefferson Lab has recently specified, procured, installed, and commissioned a new versatile production electropolishing (EP) tool. Experience with EP research and operations at JLab as well as vendor interactions and experience guided development of the system specification. Detailed design and fabrication was awarded by contract to Semiconductor Process Equipment Corporation (SPEC). The delivered system was integrated into the JLab chemroom infrastructure and commissioned in 2020. The new EP tool provides much improved heat exchange from the circulating H₂SO₄/HF electrolyte and also the cavity via variable temperature external cooling water flow, resulting in quite uniform cavity wall temperature control and thus improved removal uniformity. With the JLab infrastructure, stabilized process temperature as low as 5 C is available. We describe the system and illustrate operational modes in this contribution.

Reece, C. E.↗

Blockchain Smart Contract Reference Framework and Program Logic Architecture for Transactive Energy Systems

This paper proposes a reference framework for a transactive energy market based on blockchain. The framework was designed based on the engineering requirements of a distribution-scale market; including participant needs, expected market transactions, and the cybersecurity constructs required to support a fair, secure and efficient market operation. It leverages the existing blockchain primitives to provide clear value propositions to the transactive market, including identity management (access control), data security (integrity), resiliency (decentralization, scalability and performance). The validity of the proposed framework is demonstrated using a real-time 5-min double-auction market. The results highlight its benefits while providing strong validation of applicability to blockchain within transactive energy systems.

Gourisetti, Sri Nikhil Gupta↗

WIPP MLU Incoming Vehicles Survey Document

The following SNL document contains requested radiological survey information, as part of the documentation for the TRU-waste shipment being performed by the LANL MLU team. The surveys were performed in TA-5, on July 20th, 2020: Incoming WIPP TRU-Pact trailers survey: 1-20200720-4, and, Incoming MLU trailer and mobile crane survey: 1-20200720-8 The first survey was of 2 WIPP trailers carrying 2 empty TRU Half-Pacts each. The second survey was for a trailer with the MLU team's equipment, and for the contracted mobile crane that be used for loading Half-Pacts. All information contained was completed, reviewed, and approved by SNL RP personnel, and is released for receipt and use by the LANL MLU Team and WIPP personnel at their discretion.

61 RADIATION PROTECTION AND DOSIMETRY↗

Non-Proprietary Companion to the Q1 CY2021 PathForward Final Assessment (WBS 2.4.1, Milestone PM-HI-1040)

The PathForward element of the Exascale Computing Project (ECP) Hardware and Integration (HI) focus area has met its goals of preparing the US industry for exascale system procurements and generally improving US competitiveness in the worldwide computing market. This report is a companion to the deliverable for the ECP milestone PM-HI-1040, Assess PathForward Impact Against Exascale Hardware Challenges, which gives a summary of the final status of each PathForward project, describes progress achieved against PathForward contract milestones, and includes a final assessment of each vendor’s progress on key exascale challenges. This companion document details the results of the PathForward research to the extent possible without disclosing proprietary information and the impact on products and US exascale systems. In addition, it captures lessons learned in order to inform future projects in general and in high-performance computing in particular.

97 MATHEMATICS AND COMPUTING↗

Low Count and Background Radionuclides Analysis - 20488

The US Department of Energy (DOE) is often faced with the need to evaluate radionuclides at low concentrations. When site sample data are likely to be close to threshold activity concentrations of interest, then the means by which the radiochemical analysis is performed and reported is critical. This situation can occur when differentiating from zero (presence/absence) for radionuclides that do not occur naturally, close comparison with environmental background for naturally occurring radionuclides, close comparison with a risk- or dose-based threshold concentrations of interest, or even comparisons across studies. There are several analytical issues that are of concern, but the two that appear to cause incorrect decisions to be made most often involve establishing detection limits and subtracting ambient background conditions in the laboratory. These issues are not critical when radionuclide activity concentrations are large relative to thresholds of concern, but they seem to be poorly understood when it matters. When the comparisons are important and are likely to be close to a threshold of interest, then the general contract with the analytical laboratories needs to be changed so that the right or appropriate data are obtained. The concern is that important decisions are made incorrectly more often as greater scrutiny is placed on DoE's radionuclide cleanup or monitoring decisions by the public and other stakeholders. Examples are presented of problems that have been observed for different projects, both within and outside the realm of DOE and NRC remediation and radioactive waste disposal problems, and solutions are offered that should lead to better data from which important decisions need to be made. The first example is from Los Alamos National Laboratory (LANL) and involves radionuclide concentrations in soil and rock beneath LANL's Material Disposal Area (MDA) G. An initial review of the data led to a conclusion that americium and plutonium are a long way present beneath MDA G. A more thorough review of the data that accounted properly for ambient background and the detection limits that had been established led to the opposite conclusion. Another example is from the Nevada National Security Site where tritium results from one of the wells were unexpectedly high. Proper understanding and analysis of ambient background led to the conclusion that the increased concentrations were not so obvious, and that a different contract with the analytical laboratory was needed to provide more appropriate data to support a better determination. Other examples are used from regulatory review of projects in Nevada, where background levels and secular equilibrium for naturally occurring radionuclides are not established correctly because of analytical issues. The same basic issues have also been found to create difficulties analyzing historical data from the West Valley Demonstration Project. There is evidence in the data that the apparent lack of secular equilibrium where it is expected to exist is related to ambient background subtraction or other analytical issues. A final example is presented for analysis of Tc-99 in samples of depleted uranium. In this case, two different studies that were performed only three months apart provide quite different results. The US Environmental Protection Agency (EPA) established the data quality objectives (DQO) process in the mid-1980's to establish decision performance criteria for data collection. EPA guidance (EPA G-4, for example) clearly distinguishes between DQOs and measurement performance objectives (MQOs) that should be addressed for laboratory analysis of samples. The language of DQOs and MQOs has become confused over time it seems, and the subsequent effects seem to include a lack of attention to decision performance and a routine approach to measurement quality. In order to better address radionuclide sample analysis when the concentrations are close to thresholds of concern, which might be zero for some radionuclides, background for others, and risk-based thresholds for yet others, it is important that routine laboratory analysis methods are adjusted, and that the project team and the laboratory work closely together to ensure that the data meets the MQO requirements of laboratory analysis and reporting of results, and that the MQOs effectively support project-specific DQOs. This basic approach will be applied in Los Alamos in the coming year to the collection of moisture data from underneath MDA T that will be analyzed for americium and neptunium isotopes. Proper understanding of the radiochemistry methods and reporting, and of appropriate statistical methods is critical to the success of such projects, ensuring that the right decisions are made. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

On the mechanism of performance improvement of electroactive polyvinyl chloride (PVC) gel actuators via conductive fillers

Abstract The electromechanical actuation of transparent plasticized polyvinyl chloride (PVC) gels with conductive fillers were studied. The effects of functionalized carbon nanotubes (CNTs) and 1-butyl-3-methylimidazolium tetrafluoroborate ([Bmim]BF 4 ) ionic liquid (IL) on both the electrical conduction and dielectric processes within PVC gels were investigated, and the differences between the two were clarified. Both CNTs and IL were shown to increase the conductivity of the gels and produce larger electromechanical transduction of a contraction actuator, but only CNTs were shown to increase the electrostatic adhesion force of the PVC gels. The addition of charge carriers to the gel via the inclusion of ILs was shown to significantly reduce the conductivity relaxation time, and the transient current upon voltage polarity reversal indicated multiple peaks corresponding to the introduction of carriers with different polarities and mobilities into the gel. This is believed to cause a screening effect, reducing the charge accumulation at the anode that is the foundational basis for PVC gels’ actuation mechanism. A recommendation for preferable conductive fillers for various applications is made.

36 MATERIALS SCIENCE↗

DieselGen.jl

SAND2026-22947O DieselGen.jl is a Julia tool for diesel-engine generator sizing and performance simulation. It provides a standalone implementation of FASTSim-style diesel fuel-converter behavior with differentiable efficiency and fuel-consumption calculations. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Michelen Strofer, Carlos [Sandia National Lab. (SN↗

GFCCLib: Scalable and efficient coupled-cluster Green's function library for accurately tackling many-body electronic structure problems

Coupled-cluster Green’s function (GFCC) calculation has drawn much attention in the recent years for targeting the molecular and material electronic structure problems from a many-body perspective in a systematically improvable way. However, GFCC calculations on scientific computing clusters usually suffer from expensive higher di- mensional tensor contractions in the complex space, expensive inter-process communi- cation, and severe load imbalance, which limits it’s routine use for tackling electronic structure problems. Here we present a numerical library prototype that is specifically designed for large-scale GFCC calculations. The design of the library is focused on a systematically optimal computing strategy to improve its scalability and efficiency. The performance of the library is demonstrated by the relevant profiling analysis of running GFCC calculations on remote giant computing clusters. The capability of the library is highlighted by computing a wide near valence band of a fullerene C60 molecule for the first time at the GFCCSD level that shows excellent agreement with the experimental spectrum.

Peng, Bo↗