Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “peaking capacity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Empirical characterization of vertical-tube inlets in hot-water storage tanks

Hot-water storage in residential and commercial tanks is of growing interest for peak-shifting the electrical demand associated with hot-water loads. How the water enters the tank can significantly affect the extraction efficiency of the storage. Vertical-tube inlets (VTIs) direct cold water into the tank. The VTI design influences whether large-scale mixing occurs, which can reduce the delivery capacity of the hot-water storage. In this work, the mixing at the VTI discharge was characterized by the eddy diffusivity factor (EDF) in an allometric curve fit to the ratio Re:Ri using inlet superficial velocities. The full experimental campaign tested VTI's with Re’s between 170 and 22,300 and Ri's between 0 and 376. Animated visualization of the experimentally measured data is provided, showing tank temperature evolution during inlet flows. The most predictive correlations for EDF are for VTI Re in the transition zone (i.e. ~2300 < Re < ~10,000) and at a Ri corresponding to a stably stratified tank (i.e. Ri > 5). For vertical-tubes that distribute cold water below the thermocline, increasing the EDF will decrease the stratification in a hot-water tank as EDF quantifies inlet mixing. Overall, the new correlations for VTIs can be used to design and model thermally-stratified storage tanks.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Relaxor behavior and electrothermal properties of Sn- and Nb-modified (Ba,Ca)TiO 3 Pb-free ferroelectric

Relaxor ferroelectrics have drawn attention for possible applications in solid-state cooling and thermal energy harvesting, owing to their electrothermal energy conversion properties. Here, we have synthesized and characterized the structure–property correlations of a new Sn- and Nb-doped (Ba,Ca)TiO 3 relaxor ferroelectric with large pyroelectric and electrocaloric effects over a broad temperature range. We observed two peaks for the temperature-dependent pyroelectric coefficient: (i) -(∂P/∂T) ~ 563 µC/(m 2 K) at T~ 270 K and (ii) -(∂P/∂T) ~ 1021 µC/(m 2 K) at T~ 320 K. In addition, a broad peak for electrocaloric temperature change is observed near 320 K with a relative cooling power of ~17 J/kg. These properties could be correlated to structural changes observed using X-ray diffraction at two different temperature ranges in the material. Analysis of high-energy X-ray scattering and specific heat capacity data revealed a transition from the cubic to tetragonal phase near T m ~ 320 K, whereas an additional increase in the tetragonality (c/a) of the polar phase is observed below T s ~ 270 K.

36 MATERIALS SCIENCE↗

Dual Purpose – Heating & Cooling – Thermal Battery for Flexible and Energy-Efficient Heat Pump Systems

The integration of heat pumps with thermal energy storage (HP-TES) systems is gaining attention as a viable solution for managing peak building demand driven by immense cooling and heating loads. With growing reliance on renewable energy sources, thermal energy storage offers an excellent opportunity to mitigate mismatches in thermal load between energy supply and demand. The use of phase-change material (PCM) TES is especially promising, as PCMs offer significant latent energy storage capacity with smaller temperature glides in smaller volumes compared to other TES technologies. However, challenges arise because current HP-TES architectures can load-shift only cooling or heating, not both, requiring two systems and thus doubling cost, weight, and footprint. Furthermore, current research efforts lack specific tools and techniques to advance integrated systems from concept design to end-user application, focusing on only discharge performance. To address these challenges, this research proposes a dual-mode (heating and cooling) integrated HP-TES system that uses room-temperature PCM-TES as a high-temperature heat source in heating mode and a low-temperature heat sink in cooling mode, thereby reducing temperature lifts and compressor power. Design criteria for PCM-TES heat exchangers were developed, balancing thermal-hydraulic performance with practical constraints such as available building space and weight requirements along with PCM selection considerations such as shipping conditions, moisture exposure, and number of available cycles. A detailed transient model for HP-TES systems was developed to enable rapid annual performance assessments in any US climate zone.

42 ENGINEERING↗

Controlled workplace charging of electric vehicles: The impact of rate schedules on transformer aging

To accelerate adoption of non-residential charging for electric vehicles, sites must maximize utilization of existing electrical infrastructure. In this study we model electric vehicle charging at a workplace using real charging data and evaluate the lifetime of the site’s transformer as the number of charging stations is incrementally increased. We implement and compare a range of control schemes for workplace charging including minimizing the peak load, capping the total load, minimizing bills under different rate structures with time-of-use energy costs and demand charges, and directly minimizing the transformer’s aging. These are compared by the number of vehicles they allow the transformer to support, the transformer’s health, and the operator’s electricity bill. We draw a connection between minimizing the peak load and improving the transformer’s health. We observe that minimizing the electricity bill is the best scheme by both criteria when the bill includes a demand charge; in our experiment it allowed the infrastructure to support over 67% more cars than under uncontrolled charging. To protect the transformer we recommend that demand charges or capacity management be applied to parking lots of charging electric vehicles with high infrastructure utilization, and operators schedule charging to minimize their electricity bills.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Fusing time-varying mosquito data and continuous mosquito population dynamics models

Climate change is arguably one of the most pressing issues affecting the world today and requires the fusion of disparate data streams to accurately model its impacts. Mosquito populations respond to temperature and precipitation in a nonlinear way, making predicting climate impacts on mosquito-borne diseases an ongoing challenge. Data-driven approaches for accurately modeling mosquito populations are needed for predicting mosquito-borne disease risk under climate change scenarios. Many current models for disease transmission are continuous and autonomous, while mosquito data is discrete and varies both within and between seasons. This study uses an optimization framework to fit a non-autonomous logistic model with periodic net growth rate and carrying capacity parameters for 15 years of daily mosquito time-series data from the Greater Toronto Area of Canada. The resulting parameters accurately capture the inter-annual and intra-seasonal variability of mosquito populations within a single geographic region, and a variance-based sensitivity analysis highlights the influence each parameter has on the peak magnitude and timing of the mosquito season. This method can easily extend to other geographic regions and be integrated into a larger disease transmission model. This method addresses the ongoing challenges of data and model fusion by serving as a link between discrete time-series data and continuous differential equations for mosquito-borne epidemiology models.

97 MATHEMATICS AND COMPUTING↗

Energy Arbitrage: Comparison of Options for use with LWR Nuclear Power Plants

Arbitrage is the opportunistic buying and selling of a commodity during local pricing valleys and peaks respectively to maximize economic value. This report evaluates options for energy arbitrage integrated with existing light water reactor (LWR) nuclear power plants (NPPs) where nuclear energy could be stored in a variety of forms and later recovered to generate electrical power during periods when grid electricity demand and pricing are high. The forms of energy storage examined in this report include the potential value of batteries, hydrogen, and thermal energy storage for coupling with nuclear power. Various large demand response options are also analyzed, including the production of liquid nitrogen via air separation and liquefaction, liquefaction of hydrogen, compressed hydrogen, and the cryogenic capture of CO2. Demand response refers to dispatchable loads that can cycle up or down depending on-grid electricity demand to aid in balancing the grid. Large demand response options could dispatch to aid nuclear power stations in avoiding power turndowns by providing an alternate disposition for electrical energy by producing marketable products (e.g., liquid nitrogen, hydrogen, or captured CO2). Static conditions were chosen and analyzed in this report for each option. Dynamic operation or optimization of energy arbitrage or demand response are out of scope for this report. The analysis is based on storage systems with discharge capacities of 500 MW for which various durations of storage and costs of charging (electricity cost) are examined. While the value of thermal energy to an industrial user for flexible plant operations has been previously proven as a business case, this report evaluates costs of hydrogen energy storage and leading thermal energy storage options, and large demand response loads that could be integrated with LWRs in comparison to utility-scale battery storage for use of off-peak nuclear energy. Compilation of this information will be used by the Idaho National Laboratory (INL) RAVEN/HERON systems integration and economics tool to evaluate thermal energy dispatch to industrial users. Relative ranking of energy storage options was done using a levelized cost of storage (LCOS) metric which calculates a rough breakeven cost for the system, taking into account the capital and operating costs as well as the revenue from arbitrage. Table ES1 below shows the LCOS for each of the energy storage options considered. First, in the table, lithium iron (Fe) phosphate batteries are listed as the base case for comparison against the other options. Next is hydrogen storage where most of the hydrogen analyses assumed the hydrogen to be produced using solid oxide electrolytic cell (SOEC) high temperature steam electrolysis (HTSE). The others used existing models of polymer electrolyte membrane (PEM) low temperature electrolysis to produce hydrogen. HTSE performance parameters and costs were taken from existing INL models. Various means were assumed to convert the hydrogen to electricity, including PEM fuel cells (FCs) and a gas turbine mixed in a 30 vol% mixture with natural gas. Physical storage (pressure vessels) and geological storage (natural underground features) were used to store the hydrogen as noted. Geological storage is more economical, but the locations are limited because of the requirement for pre-existing geological formations that will support storage. Thermal energy storage (TES) options were also analyzed including electro-thermal energy storage (ETES) and four different liquid sensible heat TES storage media as noted (Hitec, Hitec XL, Therminol-66, and Dowtherm A). The ETES process considered was modified using existing public documentation on an Echogen process and uses a separate supercritical CO2 charge and discharge cycle with sand as the heat storage media.

25 ENERGY STORAGE↗

Exploring the impact of nucleotide length on lipid nanoparticle structure and properties

Lipid nanoparticles (LNPs) are versatile carriers for nucleic acid (NA) therapeutics, including ASOs, siRNA, mRNA, and poly-IC. While lipid composition is known to influence LNP properties, the impact of NA length on morphology and internal structure is less understood, particularly during the stages of carrier–cargo assembly. Here, we examine NA length and lipid composition immediately after mixing using high-throughput SAXS, dynamic light scattering, and cryogenic electron microscopy. All LNPs form ordered NA/lipid compartments, with longer NAs promoting inverse hexagonal (H II ) phases and larger intercompartment distances. In contrast, short NAs, especially in formulations with SM102 ionizable lipid, favor lamellar phases. SAXS peak deconvolution quantifies ordered versus disordered phases via a Robustness of Ordered Phase factor, which correlates with particle size and encapsulation efficiency. Formulations with MC3 ionizable and DOPE helper lipids exhibit the most stable H II -phase packing, highlighting the role of helper-lipid curvature in compartment stabilization. Variations in NA compartmentalization indicate differences in payload capacity, offering a framework for rational LNP design across diverse nucleic acid cargos.

60 APPLIED LIFE SCIENCES↗

Impact of Boron-Containing Lubricant Additive on Three-Way Catalyst Reactivity and Physicochemical Properties

Boron-containing compounds are one of the lubricant additive options due to their suitable properties for additives and have been used as commercial lubricant additives. In the present study, the impact of a boron-containing lubricant oil additive, AR9100 (BR), on Pd/Rh-based three-way catalyst (TWC) performance is investigated, and the results are compared with the baseline no-additive (NA) case and the industry standard zinc dialkyl-dithiophosphate (ZDDP) results. Accelerated engine aging is performed using a genset to expose the catalysts to lubricant additives at high temperatures. All aged TWC samples are investigated for reactivity in a bench-flow reactor and characterized using a variety of analytical techniques. Compared with the no-additive case, the temperatures of 90% conversion (T 90 ) of NO, CO, C 3 H 6 , and C 3 H 8 for the ZDDP-aged TWC sample increased by 34, 30, 37, and 48 °C. However, the T 90 of all gas species for the BR-aged TWC sample are similar to the NA-aged TWC sample. Additionally, a significant decrease in water–gas shift reactivity and oxygen storage capacity is observed in the ZDDP-aged sample, but not in the BR-aged sample. Inductively coupled plasma-optical emission spectrometry (ICP-OES) analysis and electron probe microanalysis (EPMA) maps of accelerated engine aging samples show the presence of phosphorus and boron in ZDDP- and BR-aged TWC samples, respectively. However, no boron-related peaks are observed in the X-ray diffraction (XRD) pattern of the BR-aged TWC sample, which may exist in the form of an amorphous phase.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Decarbonization of Residential Building Energy Supply: Impact of Cogeneration System Performance on Energy, Environment, and Economics

Electrical and thermal loads of residential buildings present a unique opportunity for onsite power generation, and concomitant thermal energy generation, storage, and utilization, to decrease primary energy consumption and carbon dioxide intensity. This approach also improves resiliency and ability to address peak load burden effectively. Demand response programs and grid-interactive buildings are also essential to meet the energy needs of the 21st century while addressing climate impact. Given the significance of the scale of building energy consumption, this study investigates how cogeneration systems influence the primary energy consumption and carbon footprint in residential buildings. The impact of onsite power generation capacity, its electrical and thermal efficiency, and its cost, on total primary energy consumption, equivalent carbon dioxide emissions, operating expenditure, and, most importantly, thermal and electrical energy balance, is presented. The conditions at which a cogeneration approach loses its advantage as an energy efficient residential resource are identified as a function of electrical grid’s carbon footprint and primary energy efficiency. Compared to a heat pump heating system with a coefficient of performance (COP) of three, a 0.5 kW cogeneration system with 40% electrical efficiency is shown to lose its environmental benefit if the electrical grid’s carbon dioxide intensity falls below 0.4 kg CO 2 per kWh electricity.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Electron bunch dynamics and emission in particle-in-cell simulations of relativistic laser–solid interactions: On density artifacts, collisions, and numerical dispersion

Sub-optical-cycle dynamics of dense electron bunches in relativistic-intensity laser–solid interactions lead to the emission of high-order harmonics and attosecond light pulses. The capacity of particle-in-cell simulations to accurately model these dynamics is essential for the prediction of emission properties because the attosecond pulse intensity depends on the electron density distribution at the time of emission and on the temporal distribution of individual electron Lorentz-factors in an emitting electron bunch. Here, we show that in one-dimensional collisionless simulations, the peak density of the emitting electron bunch increases with the increase in the spatial resolution of the simulation grid. When collisions are added to the model, the peak electron density becomes independent of the spatial resolution. Collisions are shown to increase the spread of the peaks of Lorentz-factors of emitting electrons in time, especially in the regimes far from optimum generation conditions, thus leading to lower intensities of attosecond pulses as compared to those obtained in collisionless simulations.

Physics↗

2022 Summer Resource Adequacy in the ERCOT Region

This report is a 2022 update to the National Energy Technology Laboratory (NETL) report that examined the potential system performance of the Electric Reliability Council of Texas (ERCOT) system during the summer of 2021. Anticipated summer reserve margins in ERCOT have risen year-over-year from the 15.7 percent reported in ERCOT’s Final Seasonal Assessment of Resource Adequacy (SARA) for Summer 2021 to 22.8 percent in the Final SARA for Summer 2022, driven mostly by increases in wind and solar generation. Using data from ERCOT’s 2022 Summer SARA, Capacity, Demand and Reserves (CDR) reports, and historical performance data obtained from ERCOT and Hitachi Energy Velocity Suite, six economic dispatch scenarios using PROMOD were developed to assess the risk to ERCOT of a load shedding event for Summer 2022. The results suggests that ERCOT may be facing a very tight resource adequacy situation, with the potential for a serious shortfall during the summer peak, usually the end of July through mid-August, if demand and generator outage rates significantly exceed peak levels. Under these conditions, ERCOT will need to call on its operating tools, including Energy Emergency Alerts (EEA) and calls to conserve electricity, to maintain reliability and continue serving load. Those measures alone may not be sufficient to avert a shedding of load.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Case Study: Hybrid Carbon Conversion Using Low-Carbon Energy Sources in Coal-Producing States

The demand for more carbon efficient power sources and a decrease in natural gas prices has decreased the desire for coal power. This decrease in demand has led to massive job losses in coal mining regions over the past decade. The purpose of this project is to develop a hybrid energy system utilizing both a coal power plant and advanced reactor, which is competitive with natural gas by improving on profitability and decreasing carbon emissions. This report details the problem with a summary of the impact on the coal industry and the availability of renewable energy sources in the Appalachian region. Because of the geography of the region, variable renewable energy sources are not available without significant size and siting restrictions. However, biomass in the form of wood waste is abundant and can be used as a carbon neutral energy source. Combining biomass and coal processing, in addition to thermal power plants, can increase system profits and efficiency by providing peaking power and conversion opportunities for secondary markets. The electric load is based on publicly available demand data from Appalachian Power, which services the western Virginia and southern West Virginia in the Appalachian region. The demand information is combined by service, normalized, and scaled to an average demand of 1000 kW, which will be the basis for sizing the hybrid energy system. A traditional screening curve analysis for a coal plant and advanced reactor shows that the least cost design varies significantly based on the assumed discount rate and capital recovery period. An optimization program to size the design in TEAL based on the load curve gives 10 optimal designs, all with a negative resulting net present value (NPV) and a coal plant capacity of less than 15%. Including profits from selling captured carbon at a flat rate results in a positive NPV; however, the coal capacity factor only increases to about 40%. There are limitations with this optimization as well since the price of CO2 is likely to decrease as more is sold to the conversion market. The suggested design will combine coal power, an advanced reactor, and coal and biomass coprocessing to produce a variety of products that can be sold to the conversion market while increasing system efficiency. The analysis of conversion pathways for coal and biomass reveals that multiple options will need to be included in the analysis to produce the optimal system design. Three systems will be optimized and compared to determine the best design based on the figures of merit of total NPV and cost of carbon avoided. The first system will include a coal power plant and an advanced reactor that will sell electricity to the grid to meet demand and sell captured carbon to the conversion market. The second system adds a high-temperature steam electrolysis plant, which will utilize electricity during times of low demand to produce hydrogen and sell it to the conversion market. The third system adds biomass and coal processing with options for hydrocarbon oils, syngas to be produced for the conversion market, and electricity generation to power components within the system or provide peaking power. This analysis will be based on a new approach that combines traditional screening curve methods with a dispatch algorithm that optimizes the system based on the opportunity cost of different production options. The resulting optimization algorithm should provide results with less processing time than HERON’s decision tree method. The results from this analysis will determine an optimal design and reinforce the benefits of coal power when used in a hybrid energy system. The initial results show that the addition of a secondary market for carbon sales could result in a positive NPV and increases the capacity factor of the coal plant as compared to a design with only sales to the electricity market. The addition of more markets and additional coal consumption from biomass coprocessing could increase NPV further, replace carbon in other markets through the sale of biomass-derived hydrocarbons, and demonstrate the value of coal power technology.

01 COAL, LIGNITE, AND PEAT↗

A Vehicle-to-Grid planning framework incorporating electric vehicle user equilibrium and distribution network flexibility enhancement

The rapid surge in electric vehicle (EV) adoption, coupled with advancements in charging technologies, emphasizes the critical necessity for expanding EV recharging infrastructure. Simultaneously, the Distribution Network (DN) encounters escalating challenges in meeting charging demand during peak traffic periods. Consequently, there is a mounting demand for the deployment of innovative Vehicle-to-Grid (V2G) technologies to augment the DN’s flexibility in power dispatch and alleviate travel costs for EV users. Hence, this paper proposes an EV-user-equilibrium-(UE)-constrained V2G planning framework that enhances flexibility in the DN. The framework aims to ascertain the optimal placement and capacity of EV charging stations (EVCSs) and V2G charging piles within the Transportation Network (TN). It takes into account the equilibrium condition stemming from competitive EV charging and routing behaviors alongside the optimal expansion of DN energy resources to accommodate the electricity supplied by the V2G piles. This study commences by analyzing EV drivers’ travel decisions, considering the influence of charging and V2G pile locations and sizes. Subsequently, we tackle the Traffic Assignment Problem with User Equilibrium (TAP-UE) model to characterize the steady-state traffic flow distribution of EVs. Following this, we formulate the optimization model for the Coordinated Power and Transportation Network (CPTN), which encompasses the optimal expansion of DN facilities and traffic flow regulation under UE conditions. To mitigate the computational complexity associated with the V2G planning model, we introduce a series of linearization methods to obtain a manageable Mixed-Integer Linear Programming (MILP) solution. Finally, to validate the efficacy of our proposed planning framework, we apply it to two test systems, including a real-world case study. Through these case studies, we explore the necessity and potential benefits of V2G technologies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

CubeSat constellations provide enhanced crop phenology and digital agricultural insights using daily leaf area index retrievals

Satellite remote sensing has great potential to deliver on the promise of a data-driven agricultural revolution, with emerging space-based platforms providing spatiotemporal insights into precision-level attributes such as crop water use, vegetation health and condition and crop response to management practices. Using a harmonized collection of high-resolution Planet CubeSat, Sentinel-2, Landsat-8 and additional coarser resolution imagery from MODIS and VIIRS, we exploit a multi-satellite data fusion and machine learning approach to deliver a radiometrically calibrated and gap-filled time-series of daily leaf area index (LAI) at an unprecedented spatial resolution of 3 m. The insights available from such high-resolution CubeSat-based LAI data are demonstrated through tracking the growth cycle of a maize crop and identifying observable within-field spatial and temporal variations across key phenological stages. Daily LAI retrievals peaked at the tasseling stage, demonstrating their value for fertilizer and irrigation scheduling. An evaluation of satellite-based retrievals against field-measured LAI data collected from both rain-fed and irrigated fields shows high correlation and captures the spatiotemporal development of intra- and inter-field variations. Novel agricultural insights related to individual vegetative and reproductive growth stages were obtained, showcasing the capacity for new high-resolution CubeSat platforms to deliver actionable intelligence for precision agricultural and related applications.

54 ENVIRONMENTAL SCIENCES↗

Land-Based Wind Market Report: 2021 Edition

The U.S. Department of Energy's 2021 edition of its land-based wind market report provides an overview of key trends in the U.S. wind power market, with a focus on 2020. You can find a report, data file and presentation on the Files tab, below. Additionally, several data visualizations are available on the Visualizations tab. Highlights of this year’s update include: -Wind comprises a growing share of electricity supply: U.S. wind power capacity grew at a record pace in 2020, with 25 billion dollars invested in 16.8 GW of capacity. Wind energy output rose to account for more than 8% of the entire nation’s electricity supply, and is more than 20% in 10 states. At least 209 GW of wind are seeking transmission interconnection; 61 GW of this capacity are offshore wind and 13 GW are hybrid plants that pair wind with storage or PV. -Wind project performance has increased over time: The average capacity factor among recently built projects was over 40%, considerably higher than projects built earlier. The highest capacity factors are seen in the interior ‘wind belt’ of the country. -Turbines continue to get larger: Improved plant performance has been driven by larger turbines mounted on taller towers and featuring longer blades. In 2010, no turbines employed blades that were 115 meters in diameter or larger, but in 2020, 91% of newly installed turbines featured such rotors. Proposed projects indicate that total turbine height will continue to rise. -Low wind turbine pricing has pushed down installed project costs over the last decade: Wind turbine prices are averaging 775–850 dollars/kW. The average installed cost of wind projects in 2020 was 1,460 dollars/kW, down more than 40% since the peak in 2010, though stable for the last three years. The lowest costs were found in Texas and the (non-ISO) West. -Wind energy prices remain low, around 20 dollars/MWh in the interior of the country: After topping out at 70 dollars/MWh for power purchase agreements (PPAs) executed in 2009, the national average price of wind PPAs has dropped. In the interior ‘wind belt’ of the country, recent pricing is around 20 dollars/MWh. In the West and East, prices tend to average 30 dollars/MWh or more. These prices, which are possible in part due to federal tax support, fall below the projected future fuel costs of gas-fired generation. -Wind PPA prices are often attractive compared to wind’s grid-system market value: The value of wind in wholesale power markets is affected by the location of wind plants, their hourly output profiles, and how those characteristics correlate with real-time electricity prices and capacity markets. The market value of wind declined in 2020, following natural gas prices lower and averaging under 15 dolalrs/MWh in ERCOT, MISO, NYISO and SPP; higher values were seen in CAISO, ISO-NE and PJM. -The average levelized cost of wind energy is down to 33 dollars/MWh: Levelized costs, which exclude the impacts of federal tax incentives, vary across time and geography, but the national average stood at 33 dollars/MWh in 2020—down substantially historically, though consistent with the previous two years. Levelized costs were lowest in ERCOT, SPP, and the (non-ISO) West. -The health and climate benefits of wind in 2020 were larger than its grid-system value, and the combination of all three far exceeds the current levelized cost of wind: Wind generation reduces power-sector emissions of carbon dioxide, nitrogen oxides, and sulfur dioxide. These reductions, in turn, provide public health and climate benefits that vary regionally, but together are economically valued at an average of 76 dollars/MWh-wind nationwide in 2020. -The domestic supply chain for wind equipment is diverse: For wind projects recently installed in the U.S., domestically manufactured content is highest for nacelle assembly (>85%), towers (60-75%), and blades and hubs (30-50%), but is much lower for most components internal to the nacelle.

17 WIND ENERGY↗

The role of geography in the complex diffusion of innovations

The urban–rural divide is increasing in modern societies calling for geographical extensions of social influence modelling. Improved understanding of innovation diffusion across locations and through social connections can provide us with new insights into the spread of information, technological progress and economic development. In this work, we analyze the spatial adoption dynamics of iWiW, an Online Social Network (OSN) in Hungary and uncover empirical features about the spatial adoption in social networks. During its entire life cycle from 2002 to 2012, iWiW reached up to 300 million friendship ties of 3 million users. We find that the number of adopters as a function of town population follows a scaling law that reveals a strongly concentrated early adoption in large towns and a less concentrated late adoption. We also discover a strengthening distance decay of spread over the life-cycle indicating high fraction of distant diffusion in early stages but the dominance of local diffusion in late stages. The spreading process is modelled within the Bass diffusion framework that enables us to compare the differential equation version with an agent-based version of the model run on the empirical network. Although both model versions can capture the macro trend of adoption, they have limited capacity to describe the observed trends of urban scaling and distance decay. We find, however that incorporating adoption thresholds, defined by the fraction of social connections that adopt a technology before the individual adopts, improves the network model fit to the urban scaling of early adopters. Controlling for the threshold distribution enables us to eliminate the bias induced by local network structure on predicting local adoption peaks. Finally, we show that geographical features such as distance from the innovation origin and town size influence prediction of adoption peak at local scales in all model specifications.

97 MATHEMATICS AND COMPUTING↗

Shock response of cobalt-based cemented tungsten carbides at pressures up to 100 GPa

In the present study, shock wave experiments are conducted on General Carbide cemented tungsten carbides with 3.7 wt.% and 6.0 wt.% cobalt binder to determine their shock compression response up to 100 GPa. A three-stage particle velocity profile is observed in the experiments -- an initial elastic-rise to the Hugoniot elastic limit (HEL), an elastic-plastic ramp indicating post-yield hardening, and finally a rise to the peak shocked Hugoniot state. The results of the experiments are used to determine the HEL, shock velocity (U s ) vs. particle velocity (u p ) Hugoniot relationship, and the longitudinal stress vs. specific volume Hugoniot relationship for the two samples. Here, the HEL for the WC 3.7wt% Co and WC 6.0wt% Co samples was determined to be ~4.45 GPa and 3.72 GPa, respectively. The U s – u p relation was determined to be U s = 4.97(0.006)+1. 446 (0.018) u p for WC 3.7 wt.% Co and U s = 4.93(0.006)+1. 454(0.017)u p for the WC 6.0 wt.% Co sample at peak particle velocities>0.75 km/s. For both WC grades, in the particle velocity regime less than ~0.75 km/s, the measured shock wave velocities were found to be larger than those predicted by the linear U s –u p Hugoniot relationship, indicating the two WC samples to preserve substantial strength in the post-yield deformation regime. Both WC grades show a catastrophic drop in shear stress carrying capacity when shocked to longitudinal stresses greater than ~70 GPa.

36 MATERIALS SCIENCE↗