Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “peaking capacity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Evaluating the Grid Impact of Oregon Offshore Wind [Slides]

This analysis used high-resolution offshore wind data and a detailed production cost model (PCM) of the Western Interconnection to explore the value and operational impact of integrating offshore wind along Oregon's coastline. Leveraging local technical stakeholder expertise and input, we determined a set of scenarios to explore. These scenarios vary both offshore wind capacities and the Western Interconnection generation and transmission infrastructure. From the scenario modeling and analysis, we identified the following key findings. In addition, we simulated a subset of the scenarios for a range of historical weather years (2007-2013), to understand the robustness of our findings to different weather conditions. Trans-coastal transmission constraints and congestion are the key drivers to the curtailment of Oregon offshore wind. Once power can be delivered into the Willamette Valley, there are few system constraints that lead to a significant curtailment of offshore wind off the coast of Oregon. Approximately 2.6 GW of installed offshore wind capacity can be integrated into Oregon's power system without major upgrades to trans-coastal transmission while avoiding significant curtailment. The system value provided by offshore wind ranges between $\$65$ /MWh and $\$85$ /MWh across the various scenarios considered. Offshore wind heavily influences the flow of the cross Cascade transmission. Across all scenarios, we found a robust relationship of approximately 500-550 MW decrease in the hourly flow of the cross Cascade transmission for every 1,000 MW of hourly offshore wind generation. However, we also found there was not a strong relationship between the highest cross-Cascade transmission flow hours and high offshore wind generation, limiting the extent to which offshore wind can be considered a non-wires alternative to cross cascade transmission. Depending on the meteorological year, 880-1,580 MW and 1,650-3,100 MW can be counted on to serve coastal loads with 2.6 GW and 5 GW of offshore wind capacity, respectively. Offshore wind allows for more optimal daily and hourly scheduling of hydropower, while still complying with various technical and regulatory constraints on the water resource. Oregon offshore wind has the potential to contribute to the evening net load peak in California (i.e., mitigate duck curve challenges), however transmission congestion between California and Oregon limits this contribution. Co-located storage at the point of interconnection for offshore wind reduces curtailment when trans-coastal transmission is not upgraded, providing a non-wires alternative to increase offshore wind capacity beyond 2.6 GW.

17 WIND ENERGY↗

Development and Testing of an Advanced Cascaded Thermoelectric Residential Heat Pump

Electricity-driven heat pumps using vapor compression cycle are an energy-efficient solution to replace fossil fuel burning and reduce greenhouse gas emissions for space heating in residential buildings. However, heating capacity and Coefficient of Performance (COP) of heat pumps degrade significantly with increasing temperature difference between ambient and indoor environments. Residents and building owners are hence reluctant to fully embrace electric heat pumps. The use of conventional all-electric heat pumps also causes concern for electric utilities due to an increased winter peak demand arising from the use of supplemental electric resistance heaters. Our research is an attempt to alleviate these concerns by designing and laboratory testing a thermoelectric (TE) heat pump cascaded with a vapor compression cycle to enhance heating capacity and COP. TE modules increase the subcooling in the refrigerant liquid of the vapor compression cycle to enlarge the evaporating capacity and works at an efficiency greater than a conventional electric resistance strip. This results in a simple, affordable, efficient and highly controllable solution to adequately meet space heating needs in dwellings. The laboratory testing of the 3-stage cascaded TE heat pump performed in this research has exhibited a higher heating capacity by above 15%, while maintaining a heating COP of 2.0-3.6 in the ambient temperature range of -18˚C to 8˚C (0˚F to 47 ˚F), which represents more than 60% of winter temperatures observed in US. If successfully commercialized, this technology can advance space-heating electrification by overcoming consumer cost barrier of heat pumps.

Shen, Bo↗

Optimal hybrid power plants for electric vehicle charging demand

Transmission constraints, increasing motivations to decarbonize, and concerns over peak electric vehicle (EV) load impacts on local grids have driven electric customers to consider behind-the-meter, hybrid power plant generation and storage at the distributed-grid level for EV charging. In this study, we develop capabilities to optimize hybrid power plant component capacities for EV charging. We then demonstrate these capabilities in a case study for Boulder, Colorado, using public EV charging data as well as wind and solar resource data. Our results show system designs that balance the cost of energy with load-meeting and peak shaving performance. Within the case study, systems designed for wind, solar photovoltaic (PV), and storage resulted in lower cost of energy than those optimized for PV and storage only. This indicates that in areas where wind resource exists, hybrid power plants that include wind, PV, and battery assets can better meet EV charging loads (including peak loads that are prone to overloading local grids) than PV and battery assets alone. Future work to address limitations in this paper include extending cost modeling to include performance losses (e.g., based on operations or weather) and charging station costs to estimate levelized cost of charging, and quantifying uncertainty and error in our aggregation methods for estimating EV charging loads at the hourly timescale.

14 SOLAR ENERGY↗

Consumer Benefits of Clean Energy: Energy Efficiency

Meeting national and state decarbonization goals requires a transition to clean energy technologies. Energy efficiency, demand flexibility, renewable energy and storage can reduce consumers’ electricity bills, lower total electricity system costs, and provide health and resilience benefits. Berkeley Lab developed a series of briefs that explore these consumer benefits of a clean energy transition. This brief focuses on energy efficiency benefits, and builds on prior analysis from Berkeley Lab’s Cost of Saved Energy database. We show that energy efficiency remains a low-cost energy and capacity resource; the levelized cost of saving energy for the programs included in the analysis is $\$0.02$/kilowatt-hour and the cost of saving peak demand is less $\$120$/kilowatt. Understanding the impact of the program mix, portfolio size, and duration of implementation for customer-funded energy efficiency portfolios can guide regulatory oversight of these programs, help utilities better utilize energy efficiency as a resource, and inform building energy decarbonization policies.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Performance Characterization of InCharge™ ICE-66 V2X Bidirectional DC Fast Charger

Vehicle-to-grid (V2G) technology extends the role of Plug-in Hybrid Vehicle’s (PHEV) and Battery Electric Vehicle’s (BEV) batteries beyond transportation by enabling bidirectional power transfer between the vehicle's onboard energy storage and the utility grid. Modern battery-powered vehicles are equipped with high-capacity battery packs that remain stationary and underutilized for the majority of their operational life. A vehicle used for daily commuting may be parked and connected to charging infrastructure for 18–20 hours per day, representing a significant untapped energy resource. When considered at scale, the aggregated storage capacity of a modest fleet of 10–15 vehicles within a single parking facility can reach the MWh range, sufficient to partially offset peak demand for a mid-size commercial building or contribute meaningful ancillary services to the local grid. The ability to charge during off-peak periods when electricity prices are low and discharge during peak demand when prices are high positions EV batteries as distributed energy arbitrage assets, with the potential to offset vehicle ownership and charging costs. Beyond energy arbitrage, V2G-capable assets can provide ancillary grid services through active and reactive power injections. Active power supports grid frequency regulation, while reactive power supports local voltage regulation. Together, these capabilities establish V2G as a technically promising and economically relevant pathway toward greater integration of battery-powered vehicles into the broader energy system.

33 ADVANCED PROPULSION SYSTEMS↗

Optimizing dietary rumen-degradable starch to rumen-degradable protein ratio improves lactation performance and nitrogen utilization efficiency in mid-lactating Holstein dairy cows

The dietary rumen-degradable starch (RDS) to rumen-degradable protein (RDP) ratio, denoted as the RDS-to-RDP ratio (SPR), has been proven to enhance in vitro rumen fermentation. However, the effects of dietary SPR in vivo remain largely unexplored. This study was conducted to investigate the effect of dietary SPR on lactation performance, nutrient digestibility, rumen fermentation patterns, blood indicators, and nitrogen (N) partitioning in mid-lactating Holstein cows. Seventy-two Holstein dairy cows were randomly assigned to three groups (24 head/group), balanced for (mean ± standard deviation) days in milk (116 ± 21.5), parity (2.1 ± 0.8), milk production (42 ± 2.1 kg/d), and body weight (705 ± 52.5 kg). The cows were fed diets with low (2.1, control), medium (2.3), or high (2.5) SPR, formulated to be isoenergetic, isonitrogenous, and iso-starch. The study consisted of a one-week adaptation phase followed by an eight-week experimental period. The results indicated that the high SPR group had a lower dry matter intake compared to the other groups ( p < 0.05). A quadratic increase in milk yield and feed efficiency was observed with increasing dietary SPR ( p < 0.05), peaking in the medium SPR group. The medium SPR group exhibited a lower milk somatic cell count and a higher blood total antioxidant capacity compared to other groups ( p < 0.05). With increasing dietary SPR, there was a quadratic improvement ( p < 0.05) in the total tract apparent digestibility of crude protein, ether extract, starch, neutral detergent fiber, and acid detergent fiber. Although no treatment effect was observed in rumen pH, the rumen total volatile fatty acids concentration and microbial crude protein synthesis increased quadratically ( p < 0.05) as dietary SPR increased. The molar proportion of propionate linearly increased ( p = 0.01), while branched-chain volatile fatty acids linearly decreased ( p = 0.01) with increasing dietary SPR. The low SPR group (control) exhibited higher concentration of milk urea N, rumen ammonia N, and blood urea N than other groups ( p < 0.05). Despite a linear decrease ( p < 0.05) in the proportion of urinary N to N intake, increasing dietary SPR led to a quadratic increase ( p = 0.01) in N utilization efficiency and a quadratic decrease ( p < 0.05) in the proportion of fecal N to N intake. In conclusion, optimizing dietary SPR has the potential to enhance lactation performance and N utilization efficiency. Based on our findings, a medium dietary SPR (with SPR = 2.3) is recommended for mid-lactating Holstein dairy cows. Nevertheless, further research on rumen microbial composition and metabolites is warranted to elucidate the underlying mechanisms of the observed effects.

Chen, Panliang↗

Experimental Evaluation of Thermal Storage Performance of a Dual-Purpose Underground Thermal Battery

A geothermal heat pump (GHP) system is an energy-efficient building heating and cooling technology with great potential for reducing energy consumption and decarbonization. However, applications of GHP are still limited due to the high cost, of which 30% is related to the cost of installing the conventional vertical bore ground heat exchangers, which are usually installed in boreholes 60 meters deep. A dual-purpose underground thermal battery (DPUTB) has been developed to offer a low-cost ground heat exchanger with a built-in thermal storage capacity. The DPUTB innovatively integrates a shallow-bore ground heat exchanger (the outer tank), which can be installed in a borehole less than 6 m deep, with thermal energy storage (TES) (the inner tank). DPUTB has the potential to reduce the cost of a ground source heat pump system while allowing shifting the electric demand of the building served by the GHP system from peak to off-peak hours of the electric grid by charging and discharging the thermal storage. A lab-scale (1:125 in volume) DPUTB prototype was built. Phase change material (PCM) was added to increase the thermal storage capacity and maintain the supply water temperature from the TES within the desired range for direct cooling operation during the discharge period. As PCMs are critical to the TES performance of the DPUTB, this study compared the influence of different PCMs (including salt hydrate and organic PCMs) on the discharge performance of the DPUTB. The thermal State of Charge (SoC) of the DPUTB was used to compare the performance resulting from using different PCMs. Test results indicate that the organic PCM (Methyl Laurate) outperforms salt-hydrate PCMs due to a lower melting temperature and a narrower melting temperature range during the phase change process. The results of this study provide a guide for PCM selection and the optimal design of DPUTB.

Wang, Lingshi↗

Economically Viable Intermediate to Long Duration Hydrogen Energy Storage Solutions for Fossil Fueled Assets

This report was prepared as an account of work sponsored by the Office of Fossil Energy and Carbon Management of U.S. Department of Energy under Funding Opportunity Announcement Number DE-FOA-0002332 “Energy Storage for Fossil Power Generation”. The work aimed to explore and advance an innovative hydrogen energy storage system – the synergistically integrated hydrogen energy storage system (SIHES) – that has the following characteristics: • Compatible with existing or new coal and gas fuel electricity generation units, • best suited for intermediate to long duration energy storage, from 12 hours to weeks even months, and • capable of storing energy at the utility scale – hundreds of MWh to GWh energy storage with power output level in tens to hundreds of MW. Preliminary front-end engineering design (Pre-FEED) studies was carried out to develop and refine a site-specific SIHES as peaking power generation units (so named as HyPeaker) as the first market entry point, to demonstrate both the technical feasibility and the economic viability to integrate the HyPeaker “within the fence” of a fossil power plant. This specific site was TVA’s Johnsonville Combustion Turbine Plant. The HyPeaker was designed and engineered to integrate with a 60MW aeroderivative gas turbine unit already available at TVA’s Johnsonville site. This site-specific HyPeaker consists of an alkaline electrolyzer to produce hydrogen from CO 2 free electricity sources, an innovative low-cost high-pressure hydrogen storage system (Big-Ton) and the aero gas turbine to generate electricity using blend of hydrogen and natural gas. A holistic system level technoeconomic analysis tool specific to HyPeaker was developed to optimize the engineering design of the Johnsonville site-specific HyPeaker for cost and performance. The optimal design and specification of the Johnsonville site-specific HyPeaker are the following: • Alkaline electrolyzer: 3MW • Big-Ton storage vessel: 11,000kg H 2 at 3000psi. • 4-stage diaphragm hydrogen compressor: 55kg-H 2 /hr from 150psi to 3000psi. The HyPeaker is designed to provide sufficient hydrogen for 90% continuous operation of the HyPeaker. All major components have design life of 30 years. The capex of HyPeaker is estimated at $\$$7.1M. This included $\$$1.5M for the electrolyzer, $\$$5.6M for the storage vessel and compressor. The cost of aero gas turbine was included as it is already available at the site. Key findings are: • HyPeaker can be designed, manufactured, installed and integrated with the fossil power plants, with sub-systems and components commercially available on the market today, even when it is scaled up to an order of magnitude larger than the one at the Johnsonville site. HyPeaker is a technologically viable solution to cover a wide range of energy storage duration needs, from daily peaking operation to seasonal shifting for fossil fueled assets. • The cost advantage of SCCV based Big-Ton H 2 storage vessel made it possible to “oversize” the H 2 storage subsystem to achieve overall system level cost optimization. The benefits are two-fold. First, it allows to significantly reduce the capacity and cost of electrolyzer by spreading H 2 production over a much longer period of time when the fuel cost for electricity production is low. Second, it allows to balance the hydrogen production and usage shift over weeks to months to meet the peak demands. As such, the capital cost of HyPeaker system using the Big-Ton was less than half of the cost of a system with today’s steel tube based H 2 storage system. The HyPeaker has even better cost advantage Li-ion battery based energy storage system. The estimated capital cost of Li-Ion battery system would be at $\$$38M, under the same projected 20-year electricity generation profile of the Johnsonville site. This is over 5 times more expensive than the HyPeaker system. • Since industry scale energy storage systems do not have 100% energy conversion and storage efficiency, energy storage systems using fossil fuel generated electricity would increase the CO 2 emission. This is particularly the case for HyPeaker due to its low round trip efficiency. Therefore, a more sensible solution would be to the excessive or curtailed electricity from CO 2 emission free sources such as solar farms, wind farms or nuclear power plants, to produce hydrogen, and integrate them with the HyPeaker. Electricity from TVA’s nuclear power plants was used for the Johnsonville HyPeaker. • The economic viability of HyPeaker is expected to be further improved when global supply chains are taken into consideration. For the same Johnsonville site specific HyPeaker, the capex would be reduced to ~$\$$3.6M from ~$\$$7.1M, and the added LCOE is reduced to ~$\$$85/MWh. With the bipartisan Infrastructure Investment and Jobs Act, the cost of domestically produced HyPeaker sub-systems would be at the level of today’s global suppliers. Since the peaking units generally operate at peak usage period, thereby demanding higher price, the projected $\$$85/MWh LCOE would be within the realm of financial viability for utility operators.

08 HYDROGEN↗

High temperature fatigue behavior of Haynes 188

The high temperature, creep-fatigue behavior of Haynes 188 was investigated as an element in a broader thermomechanical fatigue life prediction model development program at the NASA-Lewis. The models are still in the development stage, but the data that were generated possess intrinsic value on their own. Results generated to date is reported. Data were generated to characterize isothermal low cycle fatigue resistance at temperatures of 316, 704, and 927 C with cyclic failure lives ranging from 10 to more than 20,000. These results follow trends that would be predicted from a knowledge of tensile properties, i.e., as the tensile ductility varies with temperature, so varies the cyclic inelastic straining capacity. Likewise, as the tensile strength decreases, so does the high cyclic fatigue resistance. A few two-minute hold-time cycles at peak compressive strain were included in tests at 760 C. These results were obtained in support of a redesign effort for the Orbital Maneuverable System engine. No detrimental effects on cyclic life were noted despite the added exposure time for creep and oxidation. Finally, a series of simulated thermal fatigue tests, referred to as bithermal fatigue tests, were conducted using 316 C as the minimum and 760 C as the maximum temperature. Only out-of-phase bithermal tests were conducted to date. These test results are intended for use as input to a more general thermomechanical fatigue life prediction model based on the concepts of the total strain version of Strainrange Partitioning.

Halford, Gary R.↗

The Role of Catholyte Modulation in Suppressing the Initial Capacity Fade of Zinc Electrolytic Manganese Dioxide Coin Cells

Despite its potential for zinc–manganese oxide batteries, electrolytic manganese dioxide (EMD) can experience capacity fade due to a deficiency in the Mn 2+ supply at the cathode electrolyte interphase (CEI) from side reactions, even in the presence of an electrolyte additive. In this work, electrolyte loading modulation at the cathode electrolyte interface (CEI) was correlated with Zn∥EMD cell capacity retention and cycling performance, as a proposed measure to curb the initial capacity fade observed in EMD. Initial galvanostatic charge/discharge cycling, with varied electrolyte loading, revealed severe capacity fade (from ~188 to 10 mAh g –1 for the highest loading of 200 μL) within the first 15 cycles. Such a decrease in cell capacity is correlated with the formation of a Mn 4+ deposit on the current collector and consequently, the Mn 2+ depletion at CEI, as was supported by elemental and Raman analyses. Interestingly, confinement of the electrolyte to the CEI at a lower (≤15 μL) electrolyte loading mitigated Mn 4+ side-deposition, maintaining the cell capacity at >80% over the first 15 cycles. Interfacial Mn supply/depletion could be monitored via voltammetric analysis based on changes of the Zn 2+ insertionreduction peak. Additional galvanostatic experiments corroborated the voltammetric interpretation and the proposed degradation pathway in the studied cell conditions. The outcomes of this work provide practical insight into coin-cell design and configuration strategies for developing Zn∥EMD batteries.

25 ENERGY STORAGE↗

The ALOHA SYSTEM

The report provides a status report and description of THE ALOHA SYSTEM research project at the University of Hawaii. THE ALOHA SYSTEM involves the analysis and construction of advanced methods of random access communications in large computer-communication systems. The existing ALOHA SYSTEM computer-communication network uses two 24,000 baud channels in the UHF band. The system employs message switching techniques similar to those of the ARPANET, in conjunction with a novel form of random access radio channel multiplexing. By means of these techniques the system has the capacity to accommodate several hundred active users of alphanumeric consoles on the two channels available. Each of these users can transmit and receive at a peak data rate of 24,000 baud although the average data rate of the users must of course be considerably less.

Abramson, N.↗

Characterization of direct readout Si:Sb and Si:Ga infrared detector arrays for space-based astronomy

Preliminary test results from the evaluation of Si:Sb and Si:Ga 58 x 62-element infrared detector arrays are presented. These devices are being characterized under background conditions and readout rates representative of operation in orbiting, crogenically-cooled infrared observatories. The arrays are hybridized to silicon direct-readout multiplexers which allow random-access and nondestructive readout. Array performance optimization is being conducted with a flexible microcomputer-based drive and readoaut electronics system. Preliminary Si:Sb measurements indicate a sense node capacitance of 0.06 pF, peak (28-micron) responsivity above 3 A/W at 2V bias, read noise of 130 rms e(-), dark current approximately 10 e(-)/s, and a well capacity greater than 10 to the 5th e(-). The limited test data available on the performance of the Si:Ga array are also discussed.

Mckelvey, Mark E.↗

Magnetobraking: Use of tether electrodynamic drag for Earth return from Mars

It has often been proposed that a vehicle returning from Mars will use aerobraking in the Earth's atmosphere to dissipate hyperbolic excess velocity to capture into Earth orbit. Here a different system for dissipating excess velocity without expenditure of reaction mass, magnetobraking, is proposed. Magnetobraking uses the force on an electrodynamic tether in the Earth's magnetic field to produce thrust. An electrodynamic tether is deployed from the spacecraft as it approaches the Earth. The Earth's magnetic field produces a force on electrical current in the tether. If the tether is oriented perpendicularly to the Earth's magnetic field and to the direction of motion of the spacecraft, force produced by the Earth's magnetic field can be used to either brake or accelerate the spacecraft without expenditure of reaction mass. The peak acceleration on the Mars return is 0.007 m/sq sec, and the amount of braking possible is dependent on the density and current-carrying capacity of the tether, but is independent of length. A superconducting tether is required. The required critical current is shown to be within the range of superconducting technology now available in the laboratory.

Landis, Geoffrey A.↗

Highly silanized cellulose biocomposites for sustainable insulation materials

Microfibrillated lignocellulose networks, derived from agricultural byproducts, represent an environmentally friendly biogenic material production due to their abundant availability to circular bioeconomy and inherent carbon sink in life cycle analysis. Yet, its vulnerability to moisture and flammability, coupled with challenges in creating highly reinforced insulation materials, poses challenges for the carbon-zero green building sector. Here we address these challenges with a new concept of in-situ grafting polymerization of nanoporous silica in pre-formed lignocellulosic fiber networks. The seamlessly integrating nanoporous silica with cellulose through hydrogen bonding networks enabled us to prepare highly reinforced biogenic composites for green building insulations. A high reinforcement biocomposite with hierarchal arrangements of nanoporous silica within the cellulose network exhibits remarkable attributes. It boasts a thermal conductivity of 24.2 mW·m –1 ·K –1 , a flexural modulus of 942 MPa, and soundproofing with a 20.8 % noise reduction, as well as the fire resistance characterized by an extended time to ignition and a reduced peak heat release rate of 144 kW·m –2 at 35 kW·m –2 of incident radiant heat flux. Furthermore, it demonstrates a reduced water absorption capacity, dropping from 5.12 g·g –1 to 0.75 g·g –1 . Altogether, this study opens the new pathways towards sustainable carbon-zero building materials in the context of circular bioeconomy.

36 MATERIALS SCIENCE↗

Historical evidence of importance to the industrialization of flat-plate silicon photovoltaic systems. Volume 1: Executive summary

An analysis is given of the Low-Cost Silicon Solar Array Project plans for the industrialization of new production technologies expected to be forthcoming as a result of the project's technology development efforts. In particular, LSSA's mandate to insure an annual production capability of 500 MW peak for the photovoltaic supply industry by 1986 is critically examined. The examination focuses on one of the concerns behind this goal -- timely development of industrial capacity to supply anticipated demand. Some of the conclusions include: (1) construction of small-scale pilot plants should be undertaken only for purposes of technology development; (2) large-scale demonstrations should be undertaken only when the technology is well in hand; (3) commercial-scale production should be left to the private sector; (4) the 500-MW annual output goal should be shifted to Program Headquarters.

Smith, J. L.↗

Exploring Phosphonium‐Based Anion Exchange Polymers for Moisture Swing Direct Air Capture of Carbon Dioxide

This study explores the performance and stability of ammonium and phosphonium-based polymeric ionic liquids (PILs) with methyl and butyl substituents in moisture-swing direct air capture of CO 2 . The polymers are synthesized with chloride counterions, followed by ion exchange to the bicarbonate ion, and tests for CO 2 capture capacity and stability under cyclic wet–dry conditions. The phosphonium polymer with methyl substituents [PVBT-MeP] demonstrates the highest CO 2 capture capacity at ≈510 µmol g⁻¹, attributed to minimal steric hindrance and stronger ion pairing with bicarbonate. However, oxidative degradation is detected by 31 P NMR spectroscopy after the moisture swing experiment, with the appearance of a phosphine oxide peak at 61.28 ppm, which indicates phosphorus oxidation as the primary degradation pathway. In contrast, the ammonium polymer with butyl substituents [PVBT-BuN] exhibits the highest stability, showing no degradation over five moisture swing cycles. Additional stability experiments in 0.5 m KHCO 3 solutions reveal no degradation for any PIL, suggesting that oxidative degradation is driven by dynamic acid-base reactions during the moisture swing cycles in the air. Furthermore, these findings reveal the potential of phosphonium-based PILs for moisture-swing direct air capture, achieving high capacity while highlighting the need for optimized stability through counterion and structural design.

36 MATERIALS SCIENCE↗

Design of a prototypical natural circulation water-based reactor cavity cooling system (RCCS) for a pebble-bed generic FHR

A prototypical natural circulation water-based reactor cavity cooling system (RCCS) for the UC Berkeley Mark-1 pebble-bed gFHR is designed based on one-dimensional thermal hydraulics modeling and optimization implemented in an in-house MATLAB code. The model employs a lumped core consisting of fuel pebble and graphite pebble regions, while the graphite reflector, vessel, and RCCS are represented as separate but energy-coupled regions. The model is derived based on steady state energy balance equations accounting for conductive heat transfer from the lumped core to the vessel and subsequent radiative heat transfer to the RCCS and convective heat transfer in the water. Further, mass flow rate is calculated based on momentum and thermal energy balance in the RCCS. Starting with ANL’s water NSTF as baseline, effects of RCCS design parameters such as size of the plate between pipes, pipe diameter, source-to-sink distance, surface emissivity, and pitch from the core are examined in an integral effects framework which accounts for subsequent variation of the mass flow rate, number of pipes, convection coefficient, mean region and surface temperatures, radiative view factors, and water outlet temperature. The importance of including a prototypical reactor design in RCCS design calculations is emphasized as the calculations show that temperature drops from the core to the RCCS fluid to transfer the heat tend to be the limitation not the heat removal capacity of the fluid. A closed-loop design is obtained with capability to safely remove up to 0.72% of the nominal reactor power at maximum estimated peak conditions and 0.40% at shutdown. The design is based on physics calculations and does not account for economic optimization.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A Scale‐Adaptive Urban Hydrologic Framework: Incorporating Network‐Level Storm Drainage Pipes Representation

Abstract Below‐ground urban stormwater networks (BUSNs) significantly influence urban flood dynamics, yet their representation at the watershed or larger scales remains challenging. We introduce a scalable urban hydrologic framework that centers on a novel network‐level BUSN representation, balancing the needs for physical basis, parameter parsimony, and computational efficiency. Our framework conceptualizes an urban watershed into four interacting zones: hillslopes (natural), storm‐sewersheds (urban), a sub‐network channel (tributaries), and a main channel. We develop an innovative Graph Theory‐based algorithm to derive network‐level BUSN parameters from publicly available datasets, enabling efficient, scalable parameterization. We demonstrate this framework's applicability at nine representative watersheds in the Houston metropolitan region, USA, with urban imperviousness ranging from 0% to 64% and drainage areas ranging from 24 to 302 . Our model achieves satisfying computational efficiency, completing hourly time step simulations for 18 years in less than 5 sec per watershed on a standard PC. Validation against observed daily streamflow confirms that the model can capture small‐to‐large flood peaks and seasonal and annual water balance over these watersheds. Comparisons with the National Water Model show better performance in predicting flood peaks and overall water balance, underscoring the promises of our new framework for urban hydrologic modeling at large scales. Furthermore, analysis reveals nonlinear relationships between BUSNs' designed capacities and flood reduction effects. Our approach bridges the gap between detailed hydraulic and large‐scale hydrologic models, providing a valuable tool for urban flood prediction and management across broader spatial and temporal scales.

54 ENVIRONMENTAL SCIENCES↗