Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “peak load”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Classification and Calculation of Drive Loads

To permit calculation of the fatigue strength of drive components, drives are classified in terms of their loading conditions. Formulas are presented for the equivalence factors used in converting the actual variable loading conditions to conventional constant conditions. The overload coefficients required in calculating the static strength of drive components at the peak load are also determined.

42 ENGINEERING↗

Proposed Protocols for Defining Requirements and Sizing of Media-Based Filters for Spacecraft and Planetary Lander Applications

The air quality control equipment aboard future deep space exploration vehicles provide the vital function of maintaining a clean cabin environment for the crew and the hardware. This becomes a serious challenge in pressurized space compartments since no outside air ventilation is possible, and a larger particulate load is imposed on the filtration system due to lack of sedimentation in low gravity, and can experience short duration peak loading of dust from planetary surfaces for Lunar or Mars landers. The filter industry has established methods to properly size filters for a given particulate load, but requirements for the space or planetary application introduce additional consideration. In this work, a methodology for properly evaluating and sizing particulate filters for a Lunar surface pressurized environment will be presented, including estimating the loading and particle size distributions of the loading based on mission requirements. In addition, a scaling analysis from single filter media sheet to full-scale filters for this application, based on recent testing, will also be presented. These results of this study may provide meaningful guidance for properly designing media-based particulate filters for the air revitalization challenges in future deep space exploration missions.

media-based filters↗

Heat pump water heater enhanced with phase change materials thermal energy storage: Modeling study

A promising solution to improve the first hour rating (FHR) of a heat pump water heater (HPWH) involves employing a secondary tank which contains phase change material (PCM) capsules. To better understand the influence of PCM thermal storage on the HPWH operational performance, a dynamic model was developed to simulate and analyze the behavior of a newly developed HPWH technology that incorporates PCM storage into a standard HPWH to optimize key parameters such as the uniform energy factor and FHR. Mathematical models of several key components of the proposed HPWH-PCM integrated thermal energy storage (TES) system, e.g., water heater tank, PCM TES tank, evaporator, compressor, and expansion valve, have been elaborated. Also, a model-based control co-simulation platform was developed to integrate a embed PCM storage HPWH dynamic model with a control model for better supporting control design, analysis, verification, and validation. The model accuracy has been validated through comparing simulation results with lab test results, with a mean average percentage error of <5.5% for most of the selected performance variables. In addition, using the developed co-simulation platform, the demand response control strategy was studied to evaluate the load flexibility of the combined HPWH-PCM storage system by shifting system power usage to outside of the 3.5 h peak load period.

25 ENERGY STORAGE↗

Near Infrared Spectroscopy Calibration for Wood Chemistry: Which Chemometric Technique Is Best for Prediction and Interpretation?

This paper addresses the precision in factor loadings during partial least squares (PLS) and principal components regression (PCR) of wood chemistry content from near infrared reflectance (NIR) spectra. The precision of the loadings is considered important because these estimates are often utilized to interpret chemometric models or selection of meaningful wavenumbers. Standard laboratory chemistry methods were employed on a mixed genus/species hardwood sample set. PLS and PCR, before and after 1st derivative pretreatment, was utilized for model building and loadings investigation. As demonstrated by others, PLS was found to provide better predictive diagnostics. However, PCR exhibited a more precise estimate of loading peaks which makes PCR better for interpretation. Application of the 1st derivative appeared to assist in improving both PCR and PLS loading precision, but due to the small sample size, the two chemometric methods could not be compared statistically. This work is important because to date most research works have committed to PLS because it yields better predictive performance. But this research suggests there is a tradeoff between better prediction and model interpretation. Future work is needed to compare PLS and PCR for a suite of spectral pretreatment techniques.

09 BIOMASS FUELS↗

Electric Vehicle and Infrastructure Systems Modeling in Washington D.C. and Baltimore

This report documents the Argonne-Exelon effort to develop and utilize an agent-based model (ATEAM) of charging demand and infrastructure expansion applicable to the Washington, DC–Baltimore, MD consolidated metropolitan area. This study extends the ATEAM model time horizon to 10 years (from 2020 to 2030), expands agent behavior modeling capabilities, incorporates more granular and extensive empirical data on charging behavior, and analyzes charging needs for a much larger population of PEVs, in keeping with regional goals for significant adoption of ZEVs. With given targets for annual BEV adoption, five scenarios were developed to examine public infrastructure needs and resulting charging load, considering different home charging availabilities, as well as different PEV consumer profiles and public charging infrastructure deployment strategies. Scenario results show that if new chargers (both L2 and DCFC) are spread more widely (as with ubiquitous deployment strategies), there will be less variation in the number of chargers added to each census tract in the study area. More importantly, widespread public charging infrastructure with ubiquitous deployment strategies reduces unmet charging demand and improves charging success, even with heavy reliance on public charging. About 80 percent of BEV drivers can charge on their first attempt in scenarios with ubiquitous deployment strategies. Moreover, widespread public charging infrastructure better meets the demand for more charging, and in return, increases BEV adoption. Low home charging availability produces higher charging loads in public locations, especially during the early morning (around 8:00 a.m.) and late afternoon (around 6:00 p.m.). The evening peak load indicates that drivers are taking advantage of public charging before heading home. Study results also indicate that even with 20 percent home charging availability in 2030, just 20 percent of drivers attempt to charge on a given day. With their relatively high electric range (200+ miles), the BEVs expected to be on the road in 2030 can handle daily commutes without re-charging for a couple of days.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The Pacific Northwest Demand Response Market Demonstration

This paper describes the implementation and results of a field demonstration wherein residential electric water heaters and thermostats, commercial building space conditioning, municipal water pump loads, and several distributed generators were coordinated to manage constrained feeder electrical distribution through the two-way communication of load status and electric price signals. The field demonstration took place in Washington and Oregon and was paid for by the U.S. Department of Energy and several northwest utilities. Price is found to be an effective control signal for managing transmission or distribution congestion. Real-time signals at 5-minute intervals are shown to shift controlled load in time. The behaviors of customers and their responses under fixed, time-ofuse, and real-time price contracts are compared. Peak loads are effectively reduced on the experimental feeder. A novel application of portfolio theory is applied to the selection of an optimal mix of customer contract types. Index Terms—demand response, power markets, retail markets, distribution automation, distributed resources, load control.

Chassin, David P.↗

Dynamic Building Load Control to Facilitate High Penetration of Solar Photovoltaic Generation (Final Technical Report)

Solar photovoltaic (PV) resources are the most common form of distributed generation in residential and commercial customer premises within electric distribution networks. A higher penetration of PV generation in distribution circuits will impose challenges on maintaining service voltages within the range of industry standards, power quality, and power flow. Buildings consume 74% of the electricity produced in the United States, and a significant portion of the building load is dispatchable, making them responsive to electrical grid needs. Oak Ridge National Laboratory—in collaboration with Southern Company; the University of Tennessee, Knoxville; and the Georgia Institute of Technology—is examining the PV integration issues in distribution-level electrical grids and developing integrated demand-side control and communication systems to enable responsive loads. The proposed responsive loads mechanism performs renewable generation following to increase the penetration of solar PV within each feeder. The specific objectives of this project are to (1) examine distribution-level PV integration scenarios to understand requirements, (2) undertake an end-to-end simulation-based design of a distributed control strategy of loads geographically near the PV generation asset to minimize the effect on the distribution feeder, (3) deploy and demonstrate the control technology developed in partnership with utilities, and (4) perform a scalability analysis at the utility scale. This 3-year integrated project aims to develop, demonstrate, and validate demand-side control technology to enable increased the penetration of renewables while mitigating challenges that arise due to their intermittency. Activities in Budget Period (BP) 1 focused on a literature review and the formal design of a control system for integrating local distribution with generation and loads. The team used modeling and simulation to evaluate the impact of varying buildings loads, variable PV generation, and power flow dynamics on the distribution circuit. The dynamic models developed in BP 1 were used in BP 2 to develop a model-based control design and a test bed. The test bed has enabled the simulation-based testing and comparison of different control designs and formulations applied to different configurations of the distribution grid, PVs, and building loads. The control approaches developed in BP 2 were implemented in BP 3 in the form of hardware deployed at the Central Baptist Church (CBC) in Knoxville, Tennessee, for testing and evaluation. The outcome of this project was the development and demonstration of open-source, low-cost, low-touch sensing and control retrofits to distributed PV generation and building loads that, in a coordinated fashion, provide the load-shaping response needed to integrate high levels of renewable penetration. This research addresses the target metrics by dynamically controlling a load with solar generation variability to minimize the extent of two-way power flow, enhance reliability, facilitate high PV penetration (>100% of peak load in a line segment), and generate scalable software and hardware solutions adaptable to any penetration levels. The research and development activities are focused and designed to be impactful within the relevant 2020 targets time frame.An accurate open-source integration simulation framework for end-to-end control design was developed and deployed at the CBC facility for testing and evaluation. This final report provides a detailed review of the technical results achieved during this 3-year integrated project. A novel spectral analysis of PV data is demonstrated to derive the requirements of the control design. A detailed simulation-based analysis of PV integration at increasing penetration levels is presented using 1 year of PV data to demonstrate the impact on the distribution circuits. Two different control strategies were developed and demonstrated via simulation to track variable PV generation with adaptive load dispatch. The report concludes with a summary of accomplishments and recommendations for a path forward.

14 SOLAR ENERGY↗

Space shuttle SRM interim contract, part 1

Essential studies and analyses required to integrate the SRM into the booster and overall space shuttle system. Emphasis was placed on the case, nozzle, insulation, and propellant components with resulting performance, weight, and structural load characteristics being generated. Effort conducted during the time period of this contract included studies, analyses, planning, and preliminary design activities. Technical requirements identified in the SRM Project Request for Proposal No. 8-1-4-94-98401 and Thiokol's proposed SRM design (designated Configuration 0) established the basis for this effort. The requirements were evaluated jointly with MSFC and altered where necessary to incorporate new information that evolved after issuance of the RFP and during the course of this interim contract. Revised water impact loads and load distributions were provided based on additional model test data and analytical effort conducted by NASA subsequent to the RFP release. Launch pad peaking loads into the SRM aft skirt were provided which also represented a change from RFP requirements. A modified SRM/External Tank (ET) attachment configuration with new structural load data was supplied by NASA, and direction was received to include a 2 percent inert weight contingency.

Source record↗

2.1.2.403 - Fatigue and Structural Load Analysis and Control for Variable-Geometry Wave Energy Converters (VGWECs)

The VGWEC project will generate and disseminate the foundational knowledge enabling a paradigm shift in the design of wave energy converters (WECs) by adding a geometry control option on top of power-take-off load control. The variable-geometry modules (VGMs) provide control over a WEC's hydrodynamics that can emphasize power absorption or load shedding. Additional load shedding provided by the VGMs is expected to reduce the device structural mass and extend the sea state operating envelope, by limiting peak loading, both contributing towards reducing levelized cost of energy (LCOE) estimates.

hydrodynamic↗

Ducts in the Attic? What Were They Thinking? Preprint

As energy-efficiency efforts focus increasingly on existing homes, we scratch our heads about construction decisions made 30, 40, 50-years ago and ask: 'What were they thinking?' A logical follow-on question is: 'What will folks think in 2050 about the homes we're building today?' This question can lead to a lively discussion, but the current practice that we find most alarming is placing ductsin the attic. In this paper, we explore through literature and analysis the impact duct location has on cooling load, peak demand, and energy cost in hot climates. For a typical new home in these climates, we estimate that locating ducts in attics rather than inside conditioned space increases the cooling load 0.5 to 1 ton, increases cooling costs 15% and increases demand by 0.75 kW. Theaggregate demand to service duct loss in homes built in Houston, Las Vegas, and Phoenix during the period 2000 through 2009 is estimated to be 700 MW. We present options for building homes with ducts in conditioned space and demonstrate that these options compare favorably with other common approaches to achieving electricity peak demand and consumption savings in homes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Load dynamics of double planar foil liners and double planar wire arrays on the UM MAIZE LTD generator

In previous studies using the University of Nevada, Reno's (UNR's) high-impedance Zebra Marx generator (1.9 Ω, 1.7 MA, 100 ns), Double Planar Wire Arrays (DPWAs) proved to be excellent radiators, and Double Planar Foil Liners (DPFLs) proved useful for future inertial confinement fusion applications. This article presents the results of joint UNR/UM (University of Michigan) experiments with aluminum (Al) DPWAs, Al DPFLs, and tungsten (W) DPWAs using UM's Michigan Accelerator for Inductive Z-Pinch Experiments (MAIZE) generator, a low-impedance Linear Transformer Driver (LTD) (0.1 Ω, 0.5–1 MA, and 100–250 ns). The main goals of this study were twofold: the first was a pioneering effort to test whether a relatively heavy Al DPFL could successfully be imploded on a low-impedance university-scale LTD like the MAIZE generator, and, if so, to analyze the results and make comparisons to the optimized, lighter DPWA configurations that have been previously studied. The DPWAs consisted of two planes of micrometer-scale diameter Al or W wires, while the DPFLs consisted of two planes of micrometer-scale thickness Al foils. Diagnostics include filtered Si-diodes, an absolutely calibrated filtered PCD, x-ray pinhole cameras, spectrometers, and gated optical self-emission imaging. The implosion dynamics and radiative properties of Al DPWAs and DPFLs and W DPWAs on the MAIZE LTD are discussed and compared. Time-dependent load inductance calculations derived from measurements of the load current and a MAIZE circuit model provide a relative measurement of pinch strength. In experiments on MAIZE, W planar wire arrays exhibited a higher peak load inductance throughout the pinch than Al DPWAs and DPFLs, while x-ray pulses from Al DPFLs had the longest emission duration.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The use of satellites in non-geostationary orbits for unloading geostationary communication satellite traffic peaks. Volume 1: Executive summary

The overall objective of this program was to assess the application, economic benefits, and technology and system implications of satellites in non-geostationary (non-GEO) orbits for off-loading peak traffic from GEO communications satellites. The study was organized into four technical tasks which are described in turn. They are: (1) concepts development; (2) system definition; (3) economic comparisons; and (4) technology requirements definition. Each of these tasks is defined in detail and the results of each are given.

Price, K.↗

Automated Dynamic Demand Response Implementation on a Micro-grid

In this paper, we describe a system for real-time automated Dynamic and Sustainable Demand Response with sparse data consumption prediction implemented on the University of Southern California campus microgrid. Supply side approaches to resolving energy supply-load imbalance do not work at high levels of renewable energy penetration. Dynamic Demand Response (D 2 R) is a widely used demand-side technique to dynamically adjust electricity consumption during peak load periods. Our D 2 R system consists of accurate machine learning based energy consumption forecasting models that work with sparse data coupled with fast and sustainable load curtailment optimization algorithms that provide the ability to dynamically adapt to changing supply-load imbalances in near real-time. Our Sustainable DR (SDR) algorithms attempt to distribute customer curtailment evenly across sub-intervals during a DR event and avoid expensive demand peaks during a few sub-intervals. It also ensures that each customer is penalized fairly in order to achieve the targeted curtailment. We develop near linear-time constant-factor approximation algorithms along with Polynomial Time Approximation Schemes (PTAS) for SDR curtailment that minimizes the curtailment error defined as the difference between the target and achieved curtailment values. Our SDR curtailment problem is formulated as an Integer Linear Program that optimally matches customers to curtailment strategies during a DR event while also explicitly accounting for customer strategy switching overhead as a constraint. We demonstrate the results of our D 2 R system using real data from experiments performed on the USC smartgrid and show that 1) our prediction algorithms can very accurately predict energy consumption even with noisy or missing data and 2) our curtailment algorithms deliver DR with extremely low curtailment errors in the 0.01-0.05 kWh range.

Kuppannagari, Sanmukh R.↗

Maximum Photovoltaic Penetration Levels on Typical Distribution Feeders: Preprint

This paper presents simulation results for a taxonomy of typical distribution feeders with various levels of photovoltaic (PV) penetration. For each of the 16 feeders simulated, the maximum PV penetration that did not result in steady-state voltage or current violation is presented for several PV location scenarios: clustered near the feeder source, clustered near the midpoint of the feeder,clustered near the end of the feeder, randomly located, and evenly distributed. In addition, the maximum level of PV is presented for single, large PV systems at each location. Maximum PV penetration was determined by requiring that feeder voltages stay within ANSI Range A and that feeder currents stay within the ranges determined by overcurrent protection devices. Simulations were run inGridLAB-D using hourly time steps over a year with randomized load profiles based on utility data and typical meteorological year weather data. For 86% of the cases simulated, maximum PV penetration was at least 30% of peak load.

14 SOLAR ENERGY↗

Redefining Resource Adequacy for Modern Power Systems: A Report of the Redefining Resource Adequacy Task Force

Today's rapidly increasing levels of wind, solar, storage, and load flexibility require the industry to rethink reliability planning and resource adequacy methods for modern power systems. Periods with a risk of shortfall often no longer coincide with peak demand - reliability risks are less about peak load and more about the daily setting of the sun, extended cloud cover, wind speeds, cold snaps, and heat waves. In addition, demand is increasingly flexible. Key resources are time-sensitive, as batteries need time to recharge and electricity customers can only be asked to provide demand response for just so long. And reliability failures are often correlated - with one another and with the weather. Two driving factors require the industry to reconsider its analytical approach for resource adequacy: (1) Chronological grid operations: The increasing importance of variable renewable resources (such as wind and solar) and of energy-limited resources (storage and demand response) make it essential to understand the full year of chronological operation of the grid. Specific attention must be paid to hourly, seasonal, and inter-annual resource variability. The sequence of the variability is key, as energy-limited resources such as batteries or demand response require either a preceding period or subsequent period of high production to be useful for grid reliability. (2) Correlated events: Historically, resource adequacy analysis focused on shortfalls caused by random, discrete mechanical failures of large generating units. In contrast, shortfalls today are often caused by multiple, correlated events caused by common weather patterns. Resource adequacy analysis must increasingly shift its focus to these correlated events. The redesign of resource adequacy methods will benefit from a set of guiding principles to better allow for sharing of insights and best practices, interregional resource coordination, and a smoother regulatory process for resource procurement. The objective of this report is to move this redesign forward. It provides an overview of key drivers changing the way resource adequacy needs to be evaluated, identifies shortcomings of conventional approaches, and outlines first principles for practitioners to consider as they adapt their approaches. The central message is: what got us here won't get us there.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Extraction-Separation Performance and Dynamic Modeling of Orion Test Vehicles with Adams Simulation: 3rd Edition

NASA's Orion Capsule Parachute Assembly System (CPAS) Project is now in the qualification phase of testing, and the Adams simulation has continued to evolve to model the complex dynamics experienced during the test article extraction and separation phases of flight. The ability to initiate tests near the upper altitude limit of the Orion parachute deployment envelope requires extractions from the aircraft at 35,000 ft-MSL. Engineering development phase testing of the Parachute Test Vehicle (PTV) carried by the Carriage Platform Separation System (CPSS) at altitude resulted in test support equipment hardware failures due to increased energy caused by higher true airspeeds. As a result, hardware modifications became a necessity requiring ground static testing of the textile components to be conducted and a new ground dynamic test of the extraction system to be devised. Force-displacement curves from static tests were incorporated into the Adams simulations, allowing prediction of loads, velocities and margins encountered during both flight and ground dynamic tests. The Adams simulation was then further refined by fine tuning the damping terms to match the peak loads recorded in the ground dynamic tests. The failure observed in flight testing was successfully replicated in ground testing and true safety margins of the textile components were revealed. A multi-loop energy modulator was then incorporated into the system level Adams simulation model and the effect on improving test margins be properly evaluated leading to high confidence ground verification testing of the final design solution.

Varela, Jose G.↗

What is the Controllable Electrical Demand from Non-Residential Electric Vehicle Supply Equipment in the San Diego Region?

The EVSE deployed by The EV Project included both residential and non-residential units. Approximately 4,000 non-residential AC Level 2 (ACL2) EVSE were installed in workplace environments, fleet applications and publicly accessible locations near retail centers, parking lots, and similar locations. The power required to recharge a plug-in electric vehicle (PEV) can be a significant additional electrical load to electric grid but may also provide a controllable resource for mitigating grid overload issues. Electric utilities seek ways to reduce their generating costs by controlling the maximum (peak) load on their system, their generating resources, and frequency and voltage control on the system. This management may be achieved indirectly, through rates that incentivize their customers (including PEV owners) to manage the charging of their vehicles, or may take the form of direct utility control of non-residential EVSE. What insight can The EV Project data provide related to the magnitude of this impact and the potential controllable demand? The paper What is the Controllable Electrical Demand from Residential EVSE in the San Diego Region?1 addressed this question for residential EVSE. This paper quantifies the total controllable electrical load imposed on the electric grid by non-residential PEV charging in the San Diego region of The EV Project.

33 ADVANCED PROPULSION SYSTEMS↗

Enhancement of phase change material hysteresis model: A case study of modeling building envelope in EnergyPlus

Nowadays, buildings are expected to offer demand side services to the power grid to enhance the electrical load flexibility, which leads to the concepts of grid-interactive efficient buildings (GEBs). Phase change material (PCM)-based thermal energy storage has seen increasing attention in recent years for peak load shifting of grid-interactive efficient buildings (GEBs). Numerical models are critical tools for design and evaluation of PCM-integrated systems. Most industrial-grade PCMs are reported to melt/freeze over a temperature range instead of at a unique temperature. Such thermal hysteresis effect significantly affects the reliability of simulation results because not only the heat transfer process depends on melting and freezing temperatures, the PCM thermal properties change significantly during the phase change process as well. This study is aimed to develop a model for the PCMs used in the building envelope with the capability to accurately simulate hysteretic behaviors. Further, this model is based on a two-phase assumption and is implemented in a whole building energy performance simulation program (i.e., EnergyPlus). A comparison between numerical results and experimental data shows that during a complete phase transition, the two-phase model could achieve a good agreement with the experimental data. During a partial phase transition, the two-phase model could lead to significant improvements compared to other alternative PCM models, including the existing PCM model in EnergyPlus. Last, whole building simulations were performed to study this model's performance regarding heating/cooling loads and zone mean air temperature of a given building. The results show that the difference in hourly heating/cooling loads introduced by the models was less than 1% in design conditions, while significant changes were observed in both hourly heating/cooling loads and zone mean air temperature when the PCM envelope underwent partial phase transition processes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗