FY2023 NSTTF Annual Report

The National Solar Thermal Test Facility (NSTTF) is a DOE Core Capability and Technology Deployment Center located in Albuquerque, NM. It is operated by Sandia National Laboratories (Sandia) for the U.S. Department of Energy (DOE). The NSTTF is the only multi-mission, multi-use, multi-story test facility of its type in the United States. The NSTTF was founded in 1978 and began testing with high heat flux that same year. Over the past 45 years, the NSTTF has been at the forefront of the research, design, fabrication, and testing of many of the critical Concentrating Solar Power (CSP) technologies. These technologies have allowed costs to be dramatically reduced from over $\$ $0.40 /kWh to $\$$0.12 /kWh since the conception of this renewable energy technology. The NSTTF has worked to make the Solar Energy Generating Systems (SEGS) parabolic trough plants successful, while also working with the Solar One and Solar Two facilities for successful implementation. Over the four decades since its founding, the mission of the NSTTF has grown to include new receiver technologies, like our generation 3 falling particle system (G3P3 Tower), optical metrology techniques like SOFAST, molten salt testing, thermal energy storage, solar thermal chemistry, and more. We continue to expand our capabilities in pursuit of the DOE SETO mission and the DOE SunShot 2030 goals: unsubsidized LCOE of $\$$0.05/kWh for CSP that includes 12 or more hours of thermal energy storage. To support both the DOE SETO mission and support the CSP sector as a whole, we are working to develop our operations and maintenance framework to provide a world class testing facility in support of our technological achievements. To accomplish both of these missions, the NSTTF draws on the decades of experience and expertise of our staff along with the world-class facilities at Sandia National Laboratories to further the science of concentrated solar thermal technologies in diverse applications. We remain a trusted partner for high-quality and impactful research in both fundamental and applied arenas. We are able to provide our partners with both one-of-a-kind testing platforms as well as world-class analytics.

14 SOLAR ENERGY↗

Preliminary Results of the 3D-shape Round-Robin

In the framework of SFERA-III WP10 Task3, ENEA has organized the 3D-shape round-robin (RR); the purpose is to compare the main geometrical parameters of 3D shape measurement of parabolic-trough (PT) reflective panels evaluated with the instruments adopted by each participant among: ENEA, DLR, F-ISE, NREL, and SANDIA. The last two institutions are outside of the EU, but benefited from the Transnational Access institute to visit several European laboratories, including the ENEA Casaccia research center where they accomplished some measurements with a portable experimental set-up. RR is based on the inter-laboratory circulation of 3 inner plus 3 outer PT panels. The start of the RR was delayed by the covid pandemic, then the circulation of the specimen-set and their measurement took more than one year. At the time of drafting this deliverable at the end of SFERA-III project, NREL has not yet completed the analysis of the measurements, making available only the deviations of the slopes. Therefore here will be reported only the preliminary results. The full comparison will be published as soon as possible, maybe in the open access venue Open Research Europe.

14 SOLAR ENERGY↗

Radiometric Testing of Germicidal UV Products, Round 2: Upper-Room Luminaires (CALiPER Report)

This report analyzes the independently tested performance of eight germicidal ultraviolet (GUV) upper-room luminaires marketed for use in occupied spaces and purchased between March and June 2023. This type of product is mounted to upper walls or ceilings to treat air in the portion of the room above occupants; this allows for safe use of the room when the device is operating, but requires sufficient air mixing between upper and lower portions of the room. Three of the luminaires used UV-emitting LEDs, and the remaining five luminaires used low-pressure mercury (LPM) lamps. Product testing covered radiometric and electrical performance for each luminaire. Initial performance was measured for all eight products, and four were additionally measured after 100 h and 500 h of operation. Measured performance data allowed for comparison against manufacturer or vendor claims if the tested products included such claims. Some products had no performance data available for a given quantity (e.g., UV-C output power), and only four of the eight luminaires had radiant intensity distribution data files in a standard format (e.g., IES LM-63) available for download from product websites. The lack of publicly available performance data makes it difficult for potential buyers and specifiers to identify suitable products and design GUV systems for their specific applications. When products had performance claims, they were sometimes contradictory (e.g., unexplained differences between multiple power values) or ambiguous (e.g., measurement units conflict with quantity, unclear whether luminaire power or lamp power, unclear whether UV output power or UV-C output power). Three of the eight tested luminaires had claimed output power (i.e., radiant flux) values that exceeded measured values by more than an order of magnitude. There was substantial variation in UV-C radiant efficiency, with a measured range of 0.3–1.9% for LED and 0.4–2.1% for LPM, as shown in Figure 1. For example, the LPM luminaire with 0.4% radiant efficiency would need 5 times the amount of electrical energy used by the LPM luminaire with 2.1% radiant efficiency to produce the same amount of UV-C output power. LPM luminaires that had parabolic reflectors aligned with inclined louvers exhibited substantially higher UV-C radiant efficiency than tested luminaires with other designs, potentially cutting energy use by 75%. These results indicate a substantial opportunity for more energy efficient LPM luminaire designs, while demonstrating that UV LED luminaires can offer comparable UV-C radiant efficiency in this application. This may seem surprising, given that LED emitters have lower UV-C radiant efficiency than LPM lamps, but the efficiency-throttling louvers that are generally required for LPM luminaires typically are not needed for LEDs thanks to their directionality. However, lateral beam angles (which describe beam width as viewed from above) were 41–83° for LED luminaires versus 89–110° for LPM luminaires. More luminaires may be required if their lateral beam angles are relatively small, and coverage may be poor if UV-C radiant intensity distribution (i.e., beam shape) is not considered when designing systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Doppler Broadening and Other Temperature Effects

In this paper I attempt to document what I have learned and still remember about temperature effects, particularly Doppler broadening, on nuclear data, as it applies to ENDF formatted data. My focus is on the SIGMA1 method of Doppler broadening that I developed over 50 years ago. However, I do realize that there are currently many different methods used in computer codes, and I have tried to keep my discussion general as it applies to ALL of these methods. In particular, ALL of the MYTHS I describe below apply to all Doppler broadening methods: they all solve the parabolic diffusion equation in spherical geometry in (speed, reaction rate) versus temperature. These methods differ only in how the cross section is represented. So, at 85 years old here is what I still remember.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Design Basis Document / Owner’s Technical Specification for Nitrate Salt Systems in CSP Projects [Slides]

Develop a Design Basis Document / Owner’s Technical Specification for nitrate salt systems in commercial parabolic trough and central receiver projects. A Design Basis Document is to a project what a heat exchanger specification is to a heat exchanger, Extensive commercial experience in salt equipment and system design, much of it gained through mistakes and associated expenses. Distill the successful experience with nitrate salt systems from as many commercial projects as possible. Starting from 7 historical Design Basis Documents, compile a consensus description of commercial equipment and system designs.

14 SOLAR ENERGY↗

Analysis of Molten Salt Thermal Energy Storage Tank Sizing and Preheating

Molten Salt Thermal energy storage (TES) is essential for concentrating solar power (CSP) plants, enhancing their capacity factor and dispatchability to ultimately reduce electricity costs. This technology is becoming more important for other technologies including nuclear power, thermal-electrical storage, and concentrating solar thermal (CST). While molten salt TES tanks have been successfully deployed in lower-temperature parabolic-trough plants, the current state-of-the-art central receiver systems operating at temperatures up to 565 degrees Celsius have experienced costly and frequent failures. These failures are associated with the immaturity of the technology and problems in tank design, fabrication, commissioning and, sometimes, aggressive operation. A primary contributing factor is the absence of a dedicated technical standard for high-temperature molten nitrate TES tanks; designers must currently rely on existing codes like API 650 and ASME Section II, which are insufficient because they fail to account for the unique demands of high temperatures, thermal cycling, and transient conditions.

25 ENERGY STORAGE↗

First Solar Thermal Energy Planner (STEP 1) and Nationwide Industrial Heat and Power Analysis

The First Solar Thermal Energy Planner (STEP 1) and Nationwide Industrial Heat and Power Analysis (aka the STEP 1 Project or the Project) aimed to (1) developed a brand-new web tool that could provide decision support through free, rapid techno-economic analysis of behind-the-meter solar+storage systems for industrial process heat and (2) conduct high-level analyses of the cost-competitiveness of the same systems across the US in key sectors. The STEP 1 web tool collects key location, land availability, thermal load profile, proccess heat temperature and media, and other key parameters through an easy-to-use user interface (UI). The UI was designed to meet the user at their level of understanding by minimizing the number of required inputs as much as possible while including options for more nuanced inputs if the user desires. STEP 1 advises users on which solar thermal tehcnologies that could fit their needs based on the inputs provided (namely process media and temperature). The tool can model a wide range of solar thermal technologies including flat plate collectors, evacuated tubes, parabolic troughs, linear Fresnel, and molten salt towers all with corresponding thermal energy storage (TES) - solar PV with resistive heating and TES is also included. Once the parameters are collected, a nominal thermal energy production profile for the facility's location is generated using NREL's System Advisory Model (SAM) and then passed to a modified version of NREL's REopt platform to optimize the size (capacity) and dispatch of the solar+storage system to minimize lifecycle costs subject to energy balance, fuel and electricity rates, emission reductions goals, and other constraints. This entire process takes less than 20 minutes, is completely free, requires zero coding skills, and provides the user with a high-level assessment on the techno-economic feasability of deploying solar+storage systems for their energy needs. In addition to the development of the STEP 1 web tool, the project completed two complementary analyses focused on leveraging the backend code of STEP 1, public industrial facility locations and fuel consumption data, and key sector information to assess the economic opportunity of reducing fuel costs at various levels of capacity factor around the US. Both analyses found that there are key markets, locations, industrial sectors (namely food and beverage), and degrees of offset where solar thermal technologies could be cost-effectively deployed, highlighting a key market entry point for these technologies, and assessing deployment potential. In summary, the STEP 1 project improved the opportunities for solar+storage systems to expand into the industrial process heat market through breaking down barriers to assessing these technologies.

14 SOLAR ENERGY↗

Solar Thermal Energy Planner (STEP 1): A New Decision Support Tool for Solar Industrial Process Heat Applications

Solar thermal technologies are a promising technology to supply low-cost thermal energy to industrial processes, but there are often significant barriers to entry to industrial owners considering these technologies for their energy demands. To overcome this barrier and convey economic value to customers, NREL and Sandia National Laboratories developed Solar Thermal Energy Planner (STEP 1), a new web-based decision support tool for solar industrial process heat systems. At SolarPACES 2024, the STEP 1 tool was still under development; progress, methodologies, and a preliminary case study was presented. With the STEP 1 tool launch in May 2025, in this work, the initial version of the full public tool will be presented with demonstrations of its capabilities using a few case studies. First, the user's process heat needs such as location, process media (e.g., steam, air), process temperature, land availability, electricity and fuel costs, among other parameters. STEP 1 features a mapping interface that allows users to draw land and roof boundaries. The process media and temperature inform technology selection criteria modules that determine the appropriate solar thermal collection technologies, as well as congruent heat transfer media (e.g., hot water, oil, salt). Once the solar thermal technology selected, its nominal thermal production for the given site is characterized using NREL's System Advisor Model (SAM). Then, a modified version of NREL's REopt optimal sizing and dispatch optimization tool determines cost-optimal sizing. Within minutes, the user receives the results of the technoeconomics analysis, including the size and performance of the cost-optimal solar-plus-storage system. The cost of the system is compared to business-as-usual (e.g., an existing, standalone natural gas boiler). Users can download key results to store for sensitivity analyses. Examples of flat plate collector, parabolic trough, and molten salt tower applications with and without PV hybridization for different industrial facility types are presented in this work. The STEP 1 tool aims to reduce barriers to the adoption of solar heating solutions stemming from a lack of familiarity and technical background with solar system design options and costs among industry stakeholders.

14 SOLAR ENERGY↗

A Demonstration System for Geological Thermal Energy Storage of Concentrating Solar Thermal

Energy storage is increasingly necessary as variable energy technologies are deployed. Seasonal energy storage can shift energy generation from the summer to the winter, but these technologies must have extremely large energy capacities and low costs. Geological Thermal Energy Storage (GeoTES) is proposed as a solution for long-term energy storage [1]. Excess thermal energy can be stored in permeable reservoirs such as aquifers and depleted hydrocarbon reservoirs for several months. The energy capacity cost of GeoTES is very low which makes it suitable for both daily- and seasonal storage of Concentrating Solar Thermal (CST) energy, thus enabling CST to provide value to electricity markets and thermal energy off-takers. A CST-GeoTES demonstration system has been funded by the U.S. Department of Energy, Solar Energy Technology Office. In this article, we will describe this demonstration system and progress that has been made in its development. The demonstration system will comprise a 2 MWth parabolic trough with an 8m aperture developed by Gossamer Space Frames, seven wells, and a 100 kWe power cycle. The demonstration system will be deployed in Kern County, California by Premier Resource Management. A techno-economic model for CST-GeoTES systems has also been developed [3] and is applied to the demonstration system and its planned future expansion. The model integrates the output of specialist models of each subsystem, which enables the performance and cost of both the subsurface and surface systems to be captured. Off-design models enable the performance to be evaluated at each hour of the year, before being aggregated to evaluate the economic potential of CST-GeoTES. Initial analysis indicates that CST-GeoTES can provide long duration energy storage capabilities with low marginal costs of energy capacity - leading to a low value of Levelized Cost of Storage (LCOS) compared to alternative technologies, see Figure 2. In this article, we investigate the cost and performance of the specific demonstration site being developed by PRM and explore a range of operational profiles that can deliver different value streams, such as daily and seasonal storage, capacity, and resiliancy.

14 SOLAR ENERGY↗

Block Island Acoustic Propagation Modeling Data

This dataset contains acoustic propagation model outputs, computational subroutines, and analysis tools for underwater sound propagation in the Block Island region, including parabolic equation (PE) model results, visualization products, and comprehensive modeling software tools.

17 WIND ENERGY↗

Assessment of the Amplification Factor Transport Transition Model for High-Mach Number Flows

In its present state, the Amplification Factor Transport (AFT) model provides an efficient alternative for high-fidelity stability methods for complex geometries subject to low-speed conditions considered in the industrial-production CFD environment. Its performance has not yet been documented for the typical transition scenarios in hypersonic conditions. The goal of the present study is to apply the AFT model to a yawed- and flared-cone configuration, for which the laminar flows respectively support the crossflow and second-mode instability mechanisms, and to compare the amplification results against high-fidelity results computed with Linear Parabolized Stability Equations (LPSE). High-resolution viscous-flow solutions are provided with OVERFLOW and COFFE. For the yawed-cone case, the AFT model yields the largest amplification in a region of the flow where the expected crossflow instability is not amplified (in the leeward symmetry plane) according to LPSE. For the flared-cone case with a wall-temperature slightly lower than the adiabatic value, the AFT model yields extremely large amplification factors (in excess of 100), exceeding the computed LPSE amplification of second-mode instability results by a factor 14. Upon considering a cold-wall condition, the model shows much smaller amplification factors, which is the opposite with respect to the expected behavior of the second mode. The AFT model does not adequately capture the crossflow and second-mode instability mechanisms in its present state.

Groot, Koen J.↗

Analysis and Optimization of a Novel Hexagonal Waveguide Concentrator for Solar Thermal Applications

This paper analyzes a novel, cost-effective planar waveguide solar concentrator design that is inspired by cellular hexagonal structures in nature with the benefits of facile installation and low operation and maintenance cost. A coupled thermal and optical analysis of solar irradiation through an ideal hexagonal waveguide concentrator integrated with a linear receiver is presented, along with a cost analysis methodology, to establish the upper limit of performance. The techno-economic model, coupled with numerical optimization, is used to determine designs that maximized power density and minimized the cost of heat in the temperature range of 100–250 °C, which constitutes more than half of the industrial process heat demand. Depending on the incident solar irradiation and the application temperature, the cost of heat for the optimal design configuration ranged between 0.1–0.27 $/W and 0.075–0.18 $/W for waveguide made of ZK7 glass and polycarbonate, respectively. A techno-economic analysis showed the potential of the technology to achieve cost as low as 80 $/m2 and 61 $/m2 for waveguide made of ZK7 glass and polycarbonate material, respectively, which is less than half the cost of state-of-the-art parabolic trough concentrators. Overall, the hexagonal waveguide solar concentrator technology shows immense potential for decarbonizing the industrial process heat and thermal desalination sectors.

14 SOLAR ENERGY↗

Carburization Kinetics of Zircalloy-4 and Its Implication for Small Modular Reactor Performance

Carburization of cladding materials has long been a concern for the nuclear industry and has led to the restricted use of high-thermal conductivity fuels such as uranium carbides. With the rise of small modular reactors (SMRs) that frequently implement a graphite core-block, carburization of reactor components is once more in the foreground as a potential failure mechanism. To ensure commercial viability for SMRs, neutron-friendly cladding materials such as Zr-based alloys are required. In this work, the carburization kinetics of Zircaloy-4 (Zry-4), for the temperature range 1073–1673 K (covering typical operating temperatures and off-normal scenarios) are established. The following Arrhenius relationship for the parabolic constant describing ZrC growth is derived: Kp (in μm2/s) = 609.35 exp(−1.505 × 105/RT)). Overall, the ZrC growth is sluggish below 1473 K which is within the operational temperature range of SMRs. In all cases the ZrC that forms from solid state reaction is hypo-stoichiometric, as confirmed through XRD. The hardness and elastic modulus of carburized Zry-4 are also examined and it is shown that despite the formation of a ZrC layer, C ingress in the Zry-4 bulk does not impact the mechanical response after carburization at 1073 K and 1473 K for 96 h.

36 MATERIALS SCIENCE↗

Reduced basis approximations of parameterized dynamical partial differential equations via neural networks

Projection-based reduced order models are effective at approximating parameter-dependent differential equations that are parametrically separable. When parametric separability is not satisfied, which occurs in both linear and nonlinear problems, projection-based methods fail to adequately reduce the computational complexity. Devising alternative reduced order models is crucial for obtaining efficient and accurate approximations to expensive high-fidelity models. In this work, we develop a timestepping procedure for dynamical parameter-dependent problems, in which a neural-network is trained to propagate the coefficients of a reduced basis expansion. This results in an online stage with a computational cost independent of the size of the underlying problem. Here, we demonstrate our method on several parabolic partial differential equations, including a problem that is not parametrically separable.

97 MATHEMATICS AND COMPUTING↗

A coupled ground heat flux–surface energy balance model of evaporation using thermal remote sensing observations

Abstract. One of the major undetermined problems in evaporation (ET) retrieval using thermal infrared remote sensing is the lack of a physically based ground heat flux (G) model and its integration within the surface energy balance (SEB) equation. Here, we present a novel approach based on coupling a thermal inertia (TI)-based mechanistic G model with an analytical surface energy balance model, Surface Temperature Initiated Closure (STIC, version STIC1.2). The coupled model is named STIC-TI. The model is driven by noon–night (13:30 and 01:30 local time) land surface temperature, surface albedo, and a vegetation index from MODIS Aqua in conjunction with a clear-sky net radiation sub-model and ancillary meteorological information. SEB flux estimates from STIC-TI were evaluated with respect to the in situ fluxes from eddy covariance measurements in diverse ecosystems of contrasting aridity in both the Northern Hemisphere and Southern Hemisphere. Sensitivity analysis revealed substantial sensitivity of STIC-TI-derived fluxes due to the land surface temperature uncertainty. An evaluation of noontime G (Gi) estimates showed 12 %–21 % error across six flux tower sites, and a comparison between STIC-TI versus empirical G models also revealed the substantially better performance of the former. While the instantaneous noontime net radiation (RNi) and latent heat flux (LEi) were overestimated (15 % and 25 %), sensible heat flux (Hi) was underestimated (22 %). Overestimation (underestimation) of LEi (Hi) was associated with the overestimation of net available energy (RNi−Gi) and use of unclosed surface energy balance flux measurements in LEi (Hi) validation. The mean percent deviations in Gi and Hi estimates were found to be strongly correlated with satellite day–night view angle difference in parabolic and linear pattern, and a relatively weak correlation was found between day–night view angle difference versus LEi deviation. Findings from this parameter-sparse coupled G–ET model can make a valuable contribution to mapping and monitoring the spatiotemporal variability of ecosystem water stress and evaporation using noon–night thermal infrared observations from future Earth observation satellite missions such as TRISHNA, LSTM, and SBG.

Bhattacharya, Bimal K.↗

Modeling the effects of active wake mixing on wake behavior through large-scale coherent structures

The use of active wake mixing (AWM) to mitigate downstream turbine wakes has created new opportunities for reducing power losses in wind farms. However, many current analytical or semi-empirical wake models do not capture the flow instabilities that are excited through the blade pitch actuation. In this work, we develop a framework, which accounts for the impacts of the large-scale coherent structures and turbulence on the mean flow, for modeling AWM. The framework uses a triple-decomposition approach for the unsteady flow field and models the mean flow and fine-scale turbulence with a parabolized Reynolds-averaged Navier–Stokes (RANS) system. The wave components are modeled using a simplified spatial linear stability formulation that captures the growth and evolution of the coherent structures. Comparisons with high-fidelity large eddy simulations (LESs) of the turbine wakes showed that this framework was able to capture the additional wake mixing and faster wake recovery in the far-wake regions for both the pulse and helix AWM strategies with minimal computational expense. In the near-wake region, some differences are observed in both the RANS velocity profiles and initial growth of the large-scale structures, which may be due to some simplifying assumptions used in the model.

17 WIND ENERGY↗

Advancing Concentrating Solar Thermal Modeling Using System Advisor Model (SAM)

Concentrating solar thermal (CST) technologies play a critical role in enabling dispatchable power and high-temperature industrial heat applications. Accurate and flexible modeling tools are essential for evaluating system performance, guiding technology research and development, and informing investment decisions. The National Laboratory of the Rockies's System Advisor Model (SAM) is a widely used techno-economic simulation platform for CST systems, providing detailed performance and financial modeling capabilities for multiple CST system configurations. SAM integrates physics-based performance models with financial analysis to simulate the behavior of complex energy systems under realistic operating conditions. For CST technologies (including tower, parabolic trough, and linear Fresnel), SAM enables hourly simulations using site-specific weather data that ensure feasible operating conditions and convergence of mass and energy between core system components (i.e., solar field, receiver, thermal energy storage, and power cycle). These capabilities allow researchers and developers to evaluate annual energy production, capacity factors, levelized cost of energy (LCOE), and system dispatch strategies. A key advantage of SAM lies in its flexibility for parametric analysis and large-scale computational studies. Users can vary system design parameters such as heliostat field layout, receiver dimensions, thermal energy storage capacity, power block sizing, and installation cost assumptions to investigate their impact on system performance and financial metrics. When combined with automated scripting through LK, SDKTool, or Python interfaces, SAM enables high-throughput simulation workflows that support sensitivity analysis, technology benchmarking, and optimization studies. These approaches are particularly valuable for next-generation CST concepts, where design spaces are large and system interactions are complex. Another important capability of SAM is its support for dispatch optimization and thermal energy storage modeling, which are central to the value proposition of CST technologies. The ability to simulate integrated storage and flexible power generation allows researchers to explore strategies that maximize grid value, improve capacity utilization, and enhance integration with variable resources such as photovoltaic and wind generation. This poster will present an overview of SAM's thermal system modeling capabilities including concentrating solar. Additionally, we will highlight new feature developments including: 1) implementing Google's OR-Tools optimization platform for faster and more robust dispatch optimization, 2) developing a new power load following controller for modeling behind-the-meter applications, 3) enabling direct modeling of CSP-PV hybrid systems with the inclusion of battery storage, and 4) developing a multi-receiver falling particle Gen3 system model.

14 SOLAR ENERGY↗

EXERGETIC: De-Risking Next-Generation Resilient Geothermal Hybrids via At-Scale Evaluation Using Virtual Emulation Digital Twin Environment for Efficient Operation

The DOE-GTO-funded project, award number 5.1.2.12, entitled "EXERGETIC - De-risking Next Generation Resilient Geothermal Hybrids via at-Scale Evaluation Using a Virtual Emulation Digital Twin Environment for Efficient Operation," advances the solution to these challenges by developing and validating a geothermal co-emulation environment implemented at the National Laboratory of the Rockies (NLR)'s Advanced Research on Integrated Energy Systems (ARIES) platform. This framework enables the de-risking of next-generation geothermal and geothermal hybrid systems through high-fidelity modeling, real-time digital emulation, advanced control strategies, and techno-economic assessment. The project focused on geothermal hybrid configurations that integrate geothermal power plants with concentrated solar power and underground thermal energy storage, enabling enhanced efficiency, flexibility, and grid support capabilities. The main goal of this project was the development of a geothermal digital co-emulation environment to demonstrate the technical and economic value of geothermal hybrid systems and their contribution to grid stability and flexibility. The EXERGETIC framework combined physics-based models, controls, and real assets at ARIES, including digital real-time simulators (DRTS), a 20-MW-scale controllable grid interface (CGI), and a 2-MW conventional generator. Detailed transient models were developed for the key subsystems of a hybrid geothermal plant, including parabolic trough solar collectors, reservoir thermal energy storage (RTES), and a binary Organic Rankine Cycle (ORC) power plant. The ORC model explicitly captured thermal inertia and off-design operation and integrated control strategies to dynamically respond to electric load profiles. The models were validated against published experimental and numerical studies, demonstrating strong agreement and confirming the accuracy and robustness of the modeling approach. The resulting digital twin represents geothermal-solar-storage systems at multiple scales (1 MW to 100 MW) and enables realistic emulation of grid-connected operation. The control architecture allows the geothermal resource to provide stable baseload generation, while solar and stored thermal energy supply flexible, dispatchable support during periods of high demand or variable grid conditions. A key contribution of the EXERGETIC project is the demonstration that geothermal hybrid systems can be designed to be active grid assets rather than passive baseload generators. Using the ARIES platform, the digital twin was evaluated under multiple grid scenarios, including load following, voltage support at the distribution level, and frequency response at the transmission level. Results show that hybrid geothermal systems can respond effectively to dynamic grid conditions, providing inertia-like behavior, primary frequency support, and voltage regulation through coordinated control. In addition to the performance and grid services capability analysis of geothermal and hybrid geothermal systems, the EXERGETIC project also focused on scalability and techno-economic analysis of geothermal hybrid plants. In particular, for the scalability analysis, machine-learning (ML)-based surrogate models were trained using data generated from the geothermal digital twin under different grid-connected scenarios and plant capacities. These ML models demonstrated strong interpolation and extrapolation capabilities across plant sizes, accurately reproducing both steady-state and transient responses with very low errors. Regarding the techno-economic analysis, plant performance results were integrated with cost models for hybrid geothermal systems, and the levelized cost of electricity (LCOE) was used as the main economic metric to evaluate system performance across a range of system capacities, solar shares, solar multiples, and storage durations. Results indicate that economies of scale significantly reduce geothermal LCOE as plant capacity increases, with large-scale systems (25-100 MW) achieving substantially lower costs than small plants. Hybridization with solar thermal energy and storage further improves economic performance by increasing capacity utilization and enabling flexible dispatch. In addition, thermal storage plays a critical role in reducing LCOE by maximizing geothermal, solar, and stored energy resources. In summary, the results from this project demonstrate that geothermal hybrid systems represent a promising alternative for increasing the energy conversion efficiency of geothermal technologies, contributing to the preservation of geothermal resources, and supporting the transition of geothermal plants from traditional baseload resources into flexible, resilient, and cost-competitive energy conversion technologies.