Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “outage management”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Evaluation of Allowed Outage Times Through Risk Priority Numbers

This paper develops and applies a new methodology for determining the Allowed Outage Times (AOTs, also referred to as Completion Times) for Limiting Conditions of Operation (LCOs) in Technical Safety Requirements (TSR) documents. AOT is defined in NUREG/CR-6141, Handbook of Methods for Risk-Based Analyses of Technical Specifications, as “the time for which a component or a train in a safety system can remain inoperable before an action is required.” Due to the risk increase incurred by loss of a safety structure, system, or component (SSC) or specific administrative control (SAC), the AOT provides “adequate time to repair a failed component without incurring undue risk.”

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Corrosion Testing of Refractory in Contact with Molten Glasses Designed for Waste Vitrification - HAL24 M1 Matrix Glasses

It is known that the predictive life of the refractory ceramic liner of nuclear waste glass melters is conservative, as demonstrated by performance of these materials such as in the Defense Waste Processing Facility (DWPF). The motivation for this task is to maximize the useful life of the melters that will be operated at the Waste Treatment and Immobilization Plant (WTP), which will in turn minimize procurement and disposal costs and melter outage times, as well as to identify maximum loadings in the waste glass of those species that corrode melter components. This task was initiated jointly with Pacific Northwest National Laboratory (PNNL) with the objective to develop a methodology and model to enable more accurate prediction of refractory service life under prototypic conditions from laboratory-scale material corrosion tests.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Corrosion Testing of Refractory in Contact with Molten Glasses Designed for Waste Vitrification – VSL Touchpoint Matrix Glasses (Revision 1)

It is known that the predictive life of the refractory ceramic liner of nuclear waste glass melters is conservative, as demonstrated by performance of these materials such as in the Defense Waste Processing Facility (DWPF).[1] The motivation for this task is to maximize the useful life of the melters that will be operated at the Waste Treatment and Immobilization Plant (WTP), which will in turn minimize procurement and disposal costs and melter outage times, as well as to identify maximum loadings in the waste glass of those species that corrode melter components. This task was initiated jointly with Pacific Northwest National Laboratory (PNNL) with the objective to develop a methodology and model to enable more accurate prediction of refractory service life under prototypic conditions from laboratory-scale material corrosion tests.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hazelwood 2030

Funding made available by both the Victoria State and Australian Federal Governments for the demonstration of low emission technologies is enabling the implementation of pilot brown coal drying technology at unit 1 of the International Power managed Hazelwood power station. This will dry the run of mine brown coal from above 60% moisture content to approximately 12% moisture content in an initial 50% feed train. It is the core component of a major upgrade programme, Hazelwood 2030 described in this article. Key features of the WTA and retrofit project can be summarised as follow: Unit 1: Installation of new turbines. Steam extraction for WTA supplying 23 kg/s. Unit output increased to between 215 and 217 MWe, with the same steam flow as the original design; Installation of boiler feed water heaters providing 3% improvement in unit boiler efficiency; Installation of a WTA fluidized bed drier sufficient to provide the fuel for 50% of the thermal heat input required for 50% cocombusiton of dried brown coal (DBC); Conversion of boiler and adaptation of the firing system to 50% co-combustion of dried brown coal and ROM brown coal; Implementation outage scheduled for 4Q, 2009; Unit 2: Installation of new turbines, unit output increased to 220 MWe, again with the same steam flow as the original design; Installation of boiler feed water heaters providing 5% improvement on unit boiler efficiency; Implementation outage scheduled for 2Q 2009. 11 figs.

01 COAL, LIGNITE, AND PEAT↗

Characterization of high level nuclear waste glass samples following extended melter idling

The Savannah River Site Defense Waste Processing Facility (DWPF) melter was recently idled with glass remaining in the melt pool and riser for approximately three months. This situation presented a unique opportunity to collect and analyze glass samples since outages of this duration are uncommon. The objective of this study was to obtain insight into the potential for crystal formation in the glass resulting from an extended idling period. The results will be used to support development of a crystal-tolerant approach for operation of the high-level waste melter at the Hanford Tank Waste Treatment and Immobilization Plant (WTP). Two glass pour stream samples were collected from DWPF when the melter was restarted after idling for three months. The samples did not contain crystallization that was detectible by X-ray diffraction. Electron microscopy identified occasional spinel and noble metal crystals of no practical significance. Occasional platinum particles were observed by microscopy as an artifact of the sample collection method. Reduction/oxidation measurements showed that the pour stream glasses were fully oxidized, which was expected after the extended idling period. Chemical analysis of the pour stream glasses revealed slight differences in the concentrations of some oxides relative to analyses of the melter feed composition prior to the idling period. While these differences may be within the analytical error of the laboratories, the trends indicate that there may have been some amount of volatility associated with some of the glass components, and that there may have been interaction of the glass with the refractory components of the melter. These changes in composition, although small, can be attributed to the idling of the melter for an extended period. The changes in glass composition resulted in a 70-100 °C increase in the predicted spinel liquidus temperature (TL) for the pour stream glass samples relative to the analysis of the melter feed prior to the outage. This indicates that the potential for spinel crystallization increased as a result of idling for an extended period. However, the predicted TL of the pour stream glasses remained 150-200 °C below the mean melt pool temperature of about 1125 °C during the idling period. Given the change in predicted TL over the three month outage, the results indicate that it is important to have a thorough understanding of spinel crystallization within the melter for WTP to operate with a volume percent crystallization constraint. This knowledge will enable process control routines to be developed that avoid bulk crystallization in the melter and allow for recovery from off-normal events. The current WTP crystal-tolerant glass program will develop an improved understanding of spinel crystallization in the WTP melter to allow for operation at maximum waste loading in glass composition systems limited by predictions of spinel crystallization.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Decommissioning of Air Sparge System at Vertical Processing Facility, Solid Waste Management Unit 077 Implementation Report

This document discusses the decommissioning of the air sparge (AS) system at the Vertical Processing Facility (VPF), Solid Waste Management Unit 077 at Kennedy Space Center, Florida completed between January 30, 2023, and February 8, 2023. A 2005 Resource Conservation and Recovery Act Facility Investigation identified chlorinated volatile organic compound impacts at the site. Following assessment activities, an AS system was in operation intermittently from April 2012 through October 2017, when the system was permanently shutdown due to equipment failure. Trichloroethene and vinyl chloride remained above their groundwater cleanup target levels in several monitoring wells and the site was moved into the Industrial Area Long Term Monitoring Program. VPF continues to be sampled biennially; the most recent event was May 2022. Successful implementation of this decommissioning project will reduce the risk of accidental AS and soil vapor extraction well damage and will lower operating costs associated with maintaining obsolete AS systems. Decommissioning the AS system at VPF included vegetation clearing to access AS wells and associated piping, abandonment of all on site AS wells, temporary electrical outage, and site restoration. At the completion of demobilization and site restoration activities, the site was returned to its original or better than original condition.

Jason J Bublitz↗

Challenges and Solutions in Operation and Lay-Up of the Modular Caustic- Side Solvent Extraction Unit - 20078

The Modular Caustic-Side Solvent Extraction (CSSX) Unit (MCU) was designed and constructed to provide interim salt waste processing so that the Liquid Waste Disposition Program (LWDP) could continue waste removal and tank closure until start-up of the Salt Waste Processing Facility (SWPF). MCU processes Clarified Salt Solution (CSS), or salt solution (SS) that has undergone actinide removal/filtration, to produce two waste streams: the cesium laden Strip Effluent (SE), which is incorporated into glass at the Defense Waste Processing Facility (DWPF), and the cesium depleted Decontaminated SS (DSS), which is incorporated into grout at the Saltstone Production Facility (SPF). MCU completed start-up in 2008 with an initial operating life of 3 years and design life of 5 years. Prior to reaching the end of the design life, multiple critical components were upgraded and/or replaced to mitigate risks associated with any delays in SWPF start-up. During the remainder of operation (until June 2019), MCU was challenged to maximize processing with minimal additional modifications to repair/improve aging infrastructure, while maintaining low levels of risk to workers and the environment. Notable challenges during the extended operating life of the facility involved both mechanical and operational issues. Two of the most significant issues were the increased frequency of Process Vessel Ventilation (PVV) High Efficiency Particulate Air (HEPA) filter change-outs and the biofouling of the SE coalescer (SEC). The major impacts of both issues were that replacement of these components 1) resulted in high exposure to workers, and 2) required substantial downtime, thus hindering achievement of processing goals. PVV HEPA filter replacements are required based on dose rate and differential pressure (dP) limits. After introducing a higher-curie feed to MCU, the operating time between change outs was reduced by approximately half. SEC replacements are required based on dP limits. After restarting from an extended outage, the operating life of the SEC was significantly reduced by more than half due to biofouling. As a result of extensive troubleshooting and process improvements, the facility was able to recover performance and extend the operating life of the PVV HEPA filters and the SEC media. Through troubleshooting both of these issues, the facility was also able to learn from prior experience and adapt in order to minimize down time and maintain throughput. Although the facility took advantage of short periods of downtime to perform nonintrusive troubleshooting and minor corrective/preventative maintenance activities, longer outages were periodically required for corrective maintenance involving process cell entry. During these outages, remote tools and specialized shield plates were employed to minimize dose to workers. Mock-ups of non-routine maintenance activities were critical to early identification of potential issues and improvements, which shortened outage duration. Consistent with the facility's operational strategy, evolutions needed for MCU layup were identified and sequenced to ensure safe conditions within the facility, meet pre-defined criteria for lay-up configuration, and protect workers, while minimizing the impact to SWPF integration. De-inventory and flushing of process areas was prioritized so that the total residual inventory was reduced as efficiently as possible. This paper discusses lessons learned and best practices from troubleshooting unique issues, performing complex maintenance activities, and implementing a layup strategy that best supports the overall system mission. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Comfort and Safety Metrics to Evaluate Customer Centric Resilience Enhancement Strategies

As the coincident events of extreme weather and major power outages continue to rise there is an increased need to implement resilience solutions. Many of these solutions are customer-centric, requiring the flexibility of demand, and many of the standard economic evaluations of these solutions do not include the benefits of resilience that are not easily quantified and monetized. Indoor air temperature has a large impact on the comfort and safety of building occupants during an extreme weather event. This work proposes metrics that can be used to compare the performance of resilience solutions in the context of comfort and safety.

Cost benefit analysis, Demand Side Management, Pow↗

SEIN: Breaking Barriers Resilient Energy System Analysis [Slides]

The Solar Energy Innovation Network (SEIN) is a collaborative research program that supports multi-stakeholder teams in researching and sharing solutions to real-world challenges associated with solar energy adoption. The Breaking Barriers project was selected to participate in the Solar Energy Innovation Network, Round 2, and was led by Groundswell, a D.C.-based clean energy project developer. The Breaking Barriers team included Partnership for Southern Equity, Atlanta University Center campus facility managers and professors, the City of Atlanta's Neighborhood Planning Unit T, and Georgia Power Company. The project aimed to design and construct innovative urban energy resiliency hubs integrating microgrid technology, solar generation, and energy storage in Atlanta colleges and communities. The hubs will help these historically Black colleges and universities (HBCUs) and the energy-burdened broader community in West Atlanta be more resilient, in addition to informing new course curricula at Atlanta University Center campuses. With many possible options for the system's battery size, the Breaking Barriers team needed insight into the relationships between BESS size, economic performance, and resilience at Spelman College's Manley Center. These insights are crucial for entering procurement negotiations with project developers, establishing resilience capabilities that the HBCU campuses can plan around, and guiding the team's fundraising targets. This analysis includes estimates of PV and battery performance, costs, savings, and resilience for multiple battery sizes. In order to provide power during a grid outage, the resilient energy system also needs to be connected to the Manley Center in a safe and island-able manner (electrically isolated from the grid). Analysis of potential electrical configurations and estimated setup costs is key to successfully entering a required interconnection agreement with Georgia Power, as well as informing requests for engineering firms to construct the system. This analysis includes conceptual options and rough order of magnitude cost estimates for electrically interconnecting the resilient energy system to the Manley Center and the grid. The Breaking Barriers team used this analysis to select preferred system characteristics and design for the resilient energy system.

14 SOLAR ENERGY↗

Plant maintenance and plant life extension issue, 2008

The focus of the March-April issue is on plant maintenance and plant life extension. Major articles include the following: Exciting time to be at the U.S. NRC, by Dale Klein, Nuclear Regulatory Commission; Extraordinary steps to ensure a minimal environmental impact, by George Vanderheyden, UniStar Nuclear Energy, LLC.; Focused on consistent reduction of outages, by Kevin Walsh, GE Hitachi Nuclear Energy; On the path towards operational excellence, by Ricardo Perez, Westinghouse Electric Company; Ability to be refuelled on-line, by Ian Trotman, CANDU Services, Atomic Energy of Canada, Ltd.; ASCA Application for maintenance of SG secondary side, by Patrick Wagner, Wolf Creek Nuclear Operating Corporation, Phillip Battaglia and David Selfridge, Westinghouse Electric Company; and, An integral part of the landscape and lives, by Tyler Lamberts, Entergy Nuclear Operations, Inc. The Industry Innovation article is titled Steam generator bowl drain repairs, by John Makar and Richard Gimple, Wolf Creek Nuclear Operating Corporation.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A Tool for the Risk-Informed Management of Critical Mission Resilience

We describe a methodology and tool for the risk-informed management and planning of mission resilience. By mapping concepts of resilience onto the elements of a streamlined risk model we are able to tap the substantial portfolio of established risk concepts to provide rapid insights in the evaluation and high-level screening of prospective resilience enhancement measures. This provides a risk-informed, levelized basis for the comparison of disparate resilience solutions and the means of establishing preferences. The methodology begins with identification of critical missions met by a site, and establishment of the supporting physical assets. Scenarios that would result in failure of these assets are systematically identified. Each scenario comprises three elements: realization of a hazard or threat resulting in loss of resources (the current focus being on power, natural gas, and water) to the asset, failure of measures in place to protect the asset against those losses, and realization of the consequent impacts. These scenarios are quantified in terms of their probabilities of occurrence and the magnitude of the resultant consequences (mission outage time), allowing risk-prioritization to focus resilience enhancement considerations. What-If? analyses are conducted through adjusting elements of the risk calculation to reflect the deployment of prospective resilience measures, by which means the efficacies of each of those measures can be compared using common risk metrics across diverse resilience strategies. This paper will also describe the insights from example applications.

resilience, risk, risk assesment, energy, water↗

Robotic Underwater Decontamination Services for Nuclear Applications-18464

Successful Underwater Robotic Decontamination Demonstrates Dose-Saving And Outage-Shortening Technology Diakont successfully provided underwater robotic decontamination services on a North American nuclear power plant's refueling cavity and dryer-separator pool in Spring 2017 using a new tool system. Historically, nuclear plant operators have conducted cleaning and decontamination of these surfaces manually, after draining water from the space. However manual decontamination is slow, and can result in excessive personnel dose exposure. The underwater robotic decontamination services present a vast improvement over manual decontamination because it reduces personnel dose exposure, reduces radwaste, doesn't impact plant chemistry, and doesn't risk inadvertently spreading contamination. Also the new decontamination method avoids the risk of personnel injury and component damage associated with hydrolasing. And by performing the decontamination robotically while the cavities are flooded, in many cases the critical path outage schedule can be shortened. Able to decontaminate horizontal, vertical, and curved surfaces, the decontamination tools easily navigate to areas within flooded cavities that are inaccessible to previous solutions, performing decontamination in parallel to other activities including fuel movement. Also, unlike other legacy solutions, the new tools do not require continuous use of an overhead crane or other method of suspension while performing the decontamination activities. The ROV-type decontamination tool attaches and drives along the cavity and component surfaces using a high-force, no-flow vortex generator, even in the presence of Residual Heat Removal (RHR) or shutdown cooling flow. Efficient, effective cleaning is performed using a rugged brushing action to detach the crud, while vacuuming it away at high flow rates to a submerged filter. At the Spring 2017 refueling outage, the decontamination services with the new methodology were so effective that no additional manual cavity decontamination was required after drain-down. Using the tool's ability to swim, attach, and crawl, field technicians decontaminated the majority of the surfaces designated by the plant operator. Preliminary surveys indicated that all contamination levels were reduced to <50 K dpm/100 cm{sup 2}, helping the utility meet their INPO/Industry collective radiation exposure goals. The new cleaning and decontamination services are ideal for servicing various underwater areas within nuclear power plants such as refueling cavities, BWR-6 drywell heads, spent fuel pools, cask loading pools and fuel transfer canals. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Making the Optimal Decision in Selecting Protective Clothing

Protective Clothing plays a major role in the decommissioning and operation of nuclear facilities. Literally thousands of dress-outs occur over the life of a decommissioning project and during outages at operational plants. In order to make the optimal decision on which type of protective clothing is best suited for the decommissioning or maintenance and repair work on radioactive systems, a number of interrelating factors must be considered. This article discusses these factors as well as surveys of plants regarding their level of usage of single use protective clothing and should help individuals making decisions about protective clothing as it applies to their application. Individuals considering using SUPC should not jump to conclusions. The survey conducted clearly indicates that plants have different drivers. An evaluation should be performed to understand the facility's true drivers for selecting clothing. It is recommended that an interdisciplinary team be formed including representatives from budgets and cost, safety, radwaste, health physics, and key user groups to perform the analysis. The right questions need to be asked and answered by the company providing the clothing to formulate a proper perspective and conclusion. The conclusions and recommendations need to be shared with senior management so that the drivers, expected results, and associated costs are understood and endorsed. In the end, the individual making the recommendation should ask himself/herself: 'Is my decision emotional, or logical and economical?' 'Have I reached the optimal decision for my plant?'.

42 ENGINEERING↗

Evaluation and Improvement of System-of-Systems Resilience in a Simulation of Wildfire Emergency Response

Because of the increasing threat that wildfires pose, there is interest in leveraging new technologies to improve firefighting. Specifically, Unmanned Aerial Systems (UAS) and UAS Traffic Management (UTM) promise to improve firefighters’ situational awareness, coordination, communications, safety, and strategy. While these technologies could be beneficial, there has been little formal investigation into how much benefit would occur and whether these benefits would outweigh hazards introduced by these systems. To better understand the impacts of these technologies, this paper presents a high-level dynamic simulation for evaluating wildfire response performance and resilience incorporating fire propagation, surveillance and communication, response planning, and the resulting mitigation actions. This simulation is then used to study the impact of communications and surveillance improvement, considering (1) the effect on fire containment and ground crew injuries and (2) the effect of introduced and existing disruptive fault scenarios. Simulating this model over a large number of scenarios finds that these changes can improve containment and reduce ground crew injuries. While these improvements generalize over both existing and introduced single-fault scenarios and thus result in a more resilient system, they could be negated if the introduced communications infrastructure is prone to full-scale outages.

modeling↗

Insight into Thermal Aging of Jacket-bonded Ethylene-propylene Rubber Cable Insulation

Electrical cables are integral to nuclear power plant operation and control during power generation, during planned outages, and during design basis events. Polymeric insulation and jacketing used in cable construction does age over time as a function of environmental stresses including heat, moisture, and radiation. Degradation of polymer mechanical properties can lead to breaks in the insulation and consequent electrical shorting. In this work we consider the thermal aging behavior of one of the two most common insulation polymer classes in nuclear power plants, ethylene-propylene rubber (EPR), both as an independent material and within a cable in which the EPR is bonded to a chlorinated polyethylene (CPE) jacket. Understanding the changes in these two materials with aging, both independently and in concert, will allow the establishment of aging lifetime curves and enable the development of effective non-destructive methods for tracking the condition of installed cables composed of similar material systems. Additional and more effective methods for monitoring the condition of installed cables are needed as a technical basis for continued safe use of aging cables in long term operation and to minimize operating costs for cable aging management through better informed retain/repair/replace decisions.

Light Water Reactors, electrical cables, aging, EP↗

An Improved Transmission Switching Algorithm for Managing Post-(N-1) Contingencies in Electricity Networks

In this presentation, we detail the shortcomings of existing transmission switching (TS) methodologies for preventing post-contingency loss of load in wide area electric power networks. Following that, we present a bi-level algorithm as an improvement to the state of the art. We show proof-of-concept level results that indicate computational viability, fast solutions, and the ability to pick the same best candidate as non computationally viable methods. Further, our method also minimizes load shedding after the contingency, thus enhancing the reliability and security of electricity supply. We also include a futuristic scenario of increased renewables and decreased natural gas sourced generators to show promising results. We grant permission for our presentation to be recorded and uploaded by the conference organizers.

24 POWER TRANSMISSION AND DISTRIBUTION↗

SRS Tank 38H and 43H Supernate Foaming Studies and Tank 38H Reel Tape Solids Characterization

Radioactive waste samples retrieved from Savannah River Site (SRS) Tanks 38H and 43H (concentrate receipt and feed tanks, respectively, for the 2H Evaporator system) were evaluated with regard to their tendency to form foams during air sparging. This work was conducted due to recent processing issues and outages in the evaporator that were believed to have resulted from sample foaming. The samples evaluated for foam formation included supernate collected in April of 2014 (near the time of the evaporator outage) as well as historical samples available within the SRNL shielded cells facility. The April samples included one Tank 43H surface sample (HTF-43-14-42), one Tank 43H sub-surface sample (HTF-43-14-43), and one Tank 38H (HTF-38-14-41) surface sample. In addition, two Tank 43H samples (HTF-43-14-8 and HTF-43-14-9) and one Tank 38H sample (HTF-38-14-6) were also evaluated along with a blended sample of various historical Tank 38H and 43H samples. Characterization results for the April samples are also provided. The composition of the samples was similar to historical evaporator system samples received at SRNL.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Prognostic Health Monitoring System: Component Selection Based on Risk Criteria and Economic Benefit Assessment

Prognostic health monitoring (PHM) is a proactive approach to monitor the ability of structures, systems, and components (SSCs) to withstand structural, thermal, and chemical loadings over the SSCs planned service lifespans. The current efforts to extend the operational license lifetime of the aging fleet of U.S. nuclear power plants from 40 to 60 years and beyond can benefit from a systematic application of PHM technology. Implementing a PHM system would strengthen the safety of nuclear power plants, reduce plant outage time, and reduce operation and maintenance costs. However, a nuclear power plant has thousands of SSCs, so implementing a PHM system that covers all SSCs requires careful planning and prioritization. This paper therefore focuses on a component selection that is based on the analysis of a component's failure probability, risk, and cost. Ultimately, the decision on component selection depend on the overall economical benefits arising from safety and operational considerations associated with implementing the PHM system.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗