Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “optical characterization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Analysis of Darkened Fragments Resulting from Laboratory Hypervelocity Experiments

NASA’s Orbital Debris Program Office (ODPO) relies on measurements from optical, radar, and in situ measurements to facilitate the development of data-driven orbital debris environmental engineering models such as the NASA Orbital Debris Engineering Model (ORDEM). For optical measurements, the ODPO relies on ground-based optical telescopes to statistically assess objects in geosynchronous orbit and, in the future, low Earth orbit (LEO). The data collected include the detected object’s orbital parameters, time of observation, and optical magnitude. The latter parameter can be converted to a size using NASA’s optical Size Estimation Model (oSEM). It is well known that the observed magnitude of orbital debris can vary based on an object's material constituents, observational geometry, and the effects of space weathering. To assess these magnitude variations, the ODPO uses the Optical Measurement Center (OMC) at NASA Johnson Space Center to characterize a variety of materials and fragments from laboratory impact tests representative of fragments that constitute the orbital debris population. One experiment was DebriSat: a 56 kg spacecraft was built to incorporate structural elements of a modern LEO spacecraft and was subjected to a hypervelocity impact test at the U.S. Air Force’s Arnold Engineering Development Complex using test parameters that may be encountered in LEO. The DebriSat project has provided an abundance of information for assessing fragmentation debris in terms of material, color, shape, size, density, mass, and other derived parameters. Prior to the impact test, the ODPO collected spectral measurements on a subset of the materials used to construct DebriSat for a “ground-truth” of their optical properties. After the successful hypervelocity impact test, the DebriSat team observed a fine, dark dust coating all the fragments. Prior research has suggested that this came from ablated material deposited on the fragments during the impact test, causing a change in the reflective properties [1]. Given that this lower reflectivity on the DebriSat fragments will influence the laboratory-acquired magnitudes used to calculate size and inform potential updates to the oSEM, it is critical to assess if this darkening effect on the DebriSat fragments is a laboratory bias or something that could occur in on-orbit breakup events. This paper will provide a brief overview of the OMC and DebriSat experiment, focused on the optical characterization of a subset of materials using broadband photometric measurements and spectroscopic measurements. In addition, elemental analysis of various DebriSat fragments and the soft-catch foam used in the hypervelocity experiment compared with pristine foam will be examined to further evaluate the source of the dark material coating all fragments. Finally, the authors will present a twofold plan 1) for assessing potential biases in laboratory impact experiments that could affect laboratory optical characterization and 2) for mitigating biases when compared with ground-based optical telescopic measurements of the orbital debris environment.

Heather Cowardin↗

Analysis of Darkened Fragments Resulting from Laboratory Hypervelocity Experiments

NASA’s Orbital Debris Program Office (ODPO) relies on measurements from optical, radar, and in situ measurements to facilitate the development of data-driven orbital debris environmental engineering models such as the NASA Orbital Debris Engineering Model (ORDEM). For optical measurements, the ODPO relies on ground-based optical telescopes to statistically assess objects in geosynchronous orbit and, in the future, low Earth orbit (LEO). The data collected include the detected object’s orbital parameters, time of observation, and optical magnitude. The latter parameter can be converted to a size using NASA’s optical Size Estimation Model (oSEM). It is well known that the observed magnitude of orbital debris can vary based on an object's material constituents, observational geometry, and the effects of space weathering. To assess these magnitude variations, the ODPO uses the Optical Measurement Center (OMC) at NASA Johnson Space Center to characterize a variety of materials and fragments from laboratory impact tests representative of fragments that constitute the orbital debris population. One experiment was DebriSat: a 56 kg spacecraft was built to incorporate structural elements of a modern LEO spacecraft and was subjected to a hypervelocity impact test at the U.S. Air Force’s Arnold Engineering Development Complex using test parameters that may be encountered in LEO. The DebriSat project has provided an abundance of information for assessing fragmentation debris in terms of material, color, shape, size, density, mass, and other derived parameters. Prior to the impact test, the ODPO collected spectral measurements on a subset of the materials used to construct DebriSat for a “ground-truth” of their optical properties. After the successful hypervelocity impact test, the DebriSat team observed a fine, dark dust coating all the fragments. Prior research has suggested that this came from ablated material deposited on the fragments during the impact test, causing a change in the reflective properties [1]. Given that this lower reflectivity on the DebriSat fragments will influence the laboratory-acquired magnitudes used to calculate size and inform potential updates to the oSEM, it is critical to assess if this darkening effect on the DebriSat fragments is a laboratory bias or something that could occur in on-orbit breakup events. This presentation will provide a brief overview of the OMC and DebriSat experiment, focused on the optical characterization of a subset of materials using broadband photometric measurements and spectroscopic measurements. In addition, elemental analysis of various DebriSat fragments and the soft-catch foam used in the hypervelocity experiment compared with pristine foam will be examined to further evaluate the source of the dark material coating all fragments. Finally, the authors will present a twofold plan 1) for assessing potential biases in laboratory impact experiments that could affect laboratory optical characterization and 2) for mitigating biases when compared with ground-based optical telescopic measurements of the orbital debris environment.

Heather Cowardin↗

Design, fabrication and testing of an optical temperature sensor

The laboratory breadboard optical temperature sensor based on the temperature dependent absorptive characteristics of a rare earth (europium) doped optical fiber. The principles of operation, materials characterization, fiber and optical component design, design and fabrication of an electrooptic interface unit, signal processing, and initial test results are discussed. Initial tests indicated that, after a brief warmup period, the output of the sensor was stable to approximately 1 C at room temperature or approximately + or - 0.3 percent of point (K). This exceeds the goal of 1 percent of point. Recommendations are presented for further performance improvement.

Morey, W. W.↗

Characterization of the Biomechanical Behavior of the Optic Nerve Sheath

A major priority in current space medicine research is to characterize the mechanisms in Visual Impairment and Intracranial Pressure (VIIP) syndrome, a group of ophthalmic changes that occur in some astronauts following long-duration spaceflight [1]. It is hypothesized that microgravity-induced cephalad fluid shifts lead to increases in intracranial pressure (ICP), which drives maladaptive remodeling of the optic nerve sheath (ONS). In this study, we investigated the effects of mechanical loading on the porcine ONS to better understand the mechanical response of the ONS to increased ICP.

fluid shift (biological)↗

Problems and possible solutions involved in hard target calibration of coherent Doppler lidar

The field of radiometry is surveyed with reference to coherent light, since the surfaces to be considered here are irradiated with coherent, polarized light. Definitions of some concepts are modified. In light of these modifications calibration problems are analyzed and solutions suggested. The most important task was to develop hard targets exhibiting minimal specular reflection (mirror-like and retroreflection) and following closely a Lambertian scattering curve. Bistable reflectometer experiments and integrating sphere measurements are used to physically characterize the targets. Optical and electron microscopy are used to physically characterize the targets. Since the BRDF matrix is not measured, this capability must be developed preferably for both bistatic and monostatic reflectometer measurements. The equipment is expensive and not yet developed. Calibration can be simplified if it can be proved that the BRDF matrix is diagonal for a diffuse scatterer.

Anderson, Richard↗

Optical Detection of Formaldehyde

The potential for buildup .of formaldehyde in closed space environments poses a direct health hazard to personnel. The National Aeronautic Space Agency (NASA) has established a maximum permitted concentration of 0.04 ppm for 7 to 180 days for all space craft. Early detection is critical to ensure that formaldehyde levels do not accumulate. above these limits. New sensor technologies are needed to enable real time,in situ detection in a compact and reusable form factor. Addressing this need,research into the use of reactive fluorescent dyes which reversibly bind to formaldehyde (liquid or gas) has been conducted to support the development of a formaldehyde.sensor. In the presence of formaldehyde the dyes' characteristic fluorescence peaks shift providing the basis for an optical detection. Dye responses to formaldehyde exposure were characterized; demonstrating the optical detection of formaldehyde in under 10 seconds and down to concentrations of 0.5 ppm. To .incorporate the dye .in.an optical sensor device requires. a means of containing and manipulating the dye. Multiple form factors using two dissimilar s~bstrates were considered to determine a suitable configuration. A prototype sensor was demonstrated and considerations for a field able sensor were presented. This research provides a necessary first step toward the development of a compact, reusable; real time optical formaldehyde sensor suitable for use in the U.S. space program,

Patty, Kira D.↗

Optical Testing Using Portable Laser Coordinate Measuring Instruments

High precision, portable coordinate measuring instruments (CMI) such as laser radars (LR) and laser trackers (LT) have been used for optical system alignment and integration. The LRs ability to perform a non-contact scan of surfaces was previously utilized to characterize large spherical and aspheric mirrors. In this paper, we explore the use of a CMI as an accurate, fast, robust, and non-contact tool for prescription characterization of powered optical surfaces. Using Nikons MV-224350 LR and Leicas Absolute Tracker AT401402 instruments, proof of concept measurements were performed to characterize a variety of optical components by measuring the actual and apparent, or equivalently the direct and through (DT), coordinates of calibrated metrology targets. Custom macros in metrology software and other data reduction code were developed to compute surface-ray intercepts and surface slopes from the DT shots. The calculated data is fit to an aspheric surface formula to obtain the optimum prescription. The results were compared to the nominal parameters and were crosschecked using LR scans or other approaches. We discuss potential applications across the fields of optical component fabrication and system alignment and testing.

Khreishi, M.↗

Optical Testing Using Portable Laser Coordinate Measuring Instruments

High precision, portable coordinate measuring instruments (CMI) such as laser radars (LR) and laser trackers (LT) have been used for optical system alignment and integration. The LR's ability to perform a non-contact scan of surfaces was previously utilized to characterize large spherical and aspheric mirrors. In this paper, we explore the use of a CMI as an accurate, fast, robust, and non-contact tool for prescription characterization of powered optical surfaces. Using Nikon's MV-224/350 LR and Leica's Absolute Tracker AT401/402 instruments, proof of concept measurements were performed to characterize a variety of optical components by measuring the actual and apparent, or equivalently the "direct and through" (D&T), coordinates of calibrated metrology targets. Custom macros in metrology software and other data reduction code were developed to compute surface-ray intercepts and surface slopes from the D&T shots. The calculated data is fit to an aspheric surface formula to obtain the optimum prescription. The results were compared to the nominal parameters and were crosschecked using LR scans or other approaches. We discuss potential applications across the fields of optical component fabrication and system alignment and testing.

Khreishi, Manal↗

SeaWiFS technical report series. Volume 20: The SeaWiFS bio-optical archive and storage system (SeaBASS), part 1

This document provides an overview of the Sea-viewing Wide Field-of-view Sensor (SeaWiFS) Bio-Optical Archive and Storage System (SeaBASS), which will serve as a repository for numerous data sets of interest to the SeaWiFS Science Team and other approved investigators in the oceanographic community. The data collected will be those data sets suitable for the development and evaluation of bio-optical algorithms which include results from SeaWiFS Intercalibration Round-Robin Experiments (SIRREXs), prelaunch characterization of the SeaWiFS instrument by its manufacturer -- Hughes/Santa Barbara Research Center (SBRC), Marine Optical Characterization Experiment (MOCE) cruises, Marine Optical Buoy (MOBY) deployments and refurbishments, and field studies of other scientists outside of NASA. The primary goal of the data system is to provide a simple mechanism for querying the available archive and requesting specific items, while assuring that the data is made available only to authorized users. The design, construction, and maintenance of SeaBASS is the responsibility of the SeaWiFS Calibration and Validation Team (CVT). This report is concerned with documenting the execution of this task by the CVT and consists of a series of chapters detailing the various data sets involved. The topics presented are as follows: 1) overview of the SeaBASS file architecture, 2) the bio-optical data system, 3) the historical pigment database, 4) the SIRREX database, and 5) the SBRC database.

Hooker, Stanford B.↗

Characterization of Thermal Protection Systems: An Analysis of Optical & Thermal Properties

Thermal Protection System Materials & thermal control coatings were characterized by a variety of methodologies including heat flow meter method (HFM), dynamic scanning calorimetry (DSC), fourier transform infrared spectroscopy (FTIR), and Ultra-Violet & Visible light spectroscopy (UV-VIS). Physical properties were measured to aid in the construction of thermal response models for a number a projects including MEDLI and MEDLI2. Comparing pre-flight predictions with actual flight data can allow for a reduction of margins and improve designs. The models enable design of TPS for flight missions and analysis of flight data to understand aerothermal environments experienced on the mission. This presentation reveals critical information: heat capacity (cp vs T), thermal conductivity ( vs T), and emissivity (E vs T) for Super Lightweight Ablative (SLA), Phenolic Impregnated Carbon Ablative (PICA-D), & Heatshield for Extreme Entry Environment Technology (HEEET). These properties were also measured for various thermal control coatings manufactured by AZ Technology. A portion of this work is incomplete and highlights questions to investigate in the future.

Cole, Brian↗

Microemulsion characterization by the use of a noninvasive backscatter fiber optic probe

This paper demonstrates the utility of a noninvasive backscatter fiber optic probe for dynamic light-scattering characterization of a microemulsion comprising sodium dodecyl sulfate/1-butanol/ brine/heptane. The fiber probe, comprising two optical fibers precisely positioned in a stainless steel body, is a miniaturized and efficient self-beating dynamic light-scattering system. Accuracy of particle size estimation is better than +/- 2 percent.

Ansari, Rafat R.↗

X-Ray Optics for the 2020s

Three factors characterize an X-ray optics technology: angular resolution, effective area per unit mass, and production cost per unit effective area. In general, these three factors are always in conflict with one another. Every telescope that has flown so far represents an astronomically useful compromise of these factors. Of three operating X-ray telescopes, Chandra has been optimized for angular resolution (0.5); Suzaku for effective area per unit mass; and both were optimized in its own way to minimize production cost. Optics for the decade of2020 requires a combination of Chandra's angular resolution and Suzaku's effective area per unit mass. In this talk I will briefly review X -ray optics fabrication techniques that have been used in the past three decades and then present my expectations for the 2020s. In particular I will propose a couple of new techniques that should be investigated for making lightweight and high resolution X-ray optics.

Zhang, William↗

Millimeter-wave generation and characterization of a GaAs FET by optical mixing

Coherent mixing of optical radiation from a tunable continuous-wave dye laser and a stabilized He-Ne laser was used to generate millimeter-wave signals in GaAs FETs attached to printed-circuit millimeter-wave antennas. The generated signal was further down-converted to a 2-GHz IF by an antenna-coupled millimeter-wave local oscillator at 62 GHz. Detailed characterizations of power and S/N under different bias conditions have been performed. This technique is expected to allow signal generation and frequency-response evaluation of millimeter-wave devices at frequencies as high as 100 GHz.

Ni, David C.↗

Absolute Characterization of Gravity Sag for Light-Weighted Optics

Gravity-sag (G-sag) for large space-based telescopes is a critical error budget element that must be taken in consideration. Absolute characterization of gravity sag provides necessary information when testing light weighted optics so that true optical performance can be determined. A method is presented for characterizing G-sag to obtain the 0-G optical surface.

wavefront error↗

Reflected Sunlight Reduction and Characterization for a Deep-Space Optical Receiver Antenna (DSORA)

A baffle system for the elimination of first-order specular and diffuse reflection of sunlight from the sunshade of a deep-space optical receiver telescope is presented. This baffle system consists of rings of 0.5cm blades spaced 2.5 cm apart on the walls of GO hexagonal sunshade tubes that combine to form the telescope sunshade. The shadow cast by the blades, walls, and rims of the tubes prevent all first-order reflections of direct sunlight from reaching the primary mirror of the telescope. A reflection model of the sunshade without baffles is also presented for comparison. Since manufacturers of absorbing surfaces do not measure data near grazing incidence, the reflection properties at anticipated angles of incidence must be characterized. A description of reflection from matte surfaces in term of bidirectional reflection distribution function (BRDF) is presented along with a discussion of measuring BRDF near grazing incidence.

Clymer, B. D.↗

Optical transmission measurements on monocrystalline and polycrystalline cesium iodide

A summary is presented of optical measurements performed on a variety of cesium iodide samples to characterize quantitatively the optical quality of the materials, and to define and measure parameters which determine its suitability as a detector material for high energy cosmic ray experiments on HEAO-A. The general case of light transmission through a long rectangular slab under multiple internal reflections is discussed along with transmission and scattering as a function of wavelength at normal incidence. Scattering parameters are tabulated for encapsulated single crystal CsI and polyscin.

Viehmann, W.↗

Characterization of vegetation by microwave and optical remote sensing

Two series of carefully controlled experiments were conducted. First, plots of important crops (corn, soybeans, and sorghum), prairie grasses (big bluestem, switchgrass, tal fescue, orchardgrass, bromegrass), and forage legumes (alfalfa, red clover, and crown vetch) were manipulated to produce wide ranges of phytomass, leaf area index, and canopy architecture. Second, coniferous forest canopies were simulated using small balsam fir trees grown in large pots of soil and arranged systematically on a large (5 m) platform. Rotating the platform produced many new canopies for frequency and spatial averaging of the backscatter signal. In both series of experiments, backscatter of 5.0 GHz (C-Band) was measured as a function of view angle and polarization. Biophysical measurements included leaf area index, fresh and dry phytomass, water content of canopy elements, canopy height, and soil roughness and moisture content. For a subset of the above plots, additional measurements were acquired to exercise microwave backscatter models. These measurements included size and shape of leaves, stems, and fruit and the probability density function of leaf and stem angles. The relationships of the backscattering coefficients and the biophysical properties of the canopies were evaluated using statistical correlations, analysis of variance, and regression analysis. Results from the corn density and balsam fir experiments are discussed and analyses of data from the other experiments are summarized.

Daughtry, C. S. T.↗