Tomographic Reconstruction of the Neutron Time-Energy Spectrum from a Dense Plasma Focus

A dense plasma focus (DPF) nuclear fusion generator is an attractive pulsed neutron source in many applications, due to its relatively large neutron yield, produced in a short time duration. In order to design a DPF that generates neutrons within a specified time profile, or generates a neutron energy spectrum with specific properties, it is necessary to understand and be able to fully characterize the results of the fusion process releasing the neutrons. The time-energy spectrum of fusion neutrons is an ideal quantity to use to validate multiphysics codes that simulate the pinch and fusion processes, because it is a quantity that requires the physics of each of the stages leading up to and ending in the fusion reaction to be simulated correctly. In particular, since DPF fusion neutrons are not monoenergetic – and there can often be several fusion pinches creating neutrons – a computer simulation matching high quality neutron spectrum measurements provides great confidence in the fidelity of the simulation. In order to make such a comparison, it is first necessary to have quality measurements from which to infer the spectrum. In this work we pose neutron spectroscopy as the classical tomographic inverse problem from neutron time of flight data at multiple distances, but enhanced by using detector pairs designed to reduce the scatter background and with an additional measurement of the time profile of the fusion pinch near its source. The detector pairs enhance the quality of the time of flight measurements and the additional constraint posed by the measured time profile allows for temporal resolution in the spectrum reconstruction that is equal to the measurement resolution, which can be subnanosecond, and energy resolution in the 10’s of keV, without the problem being underconstrained. We present results from a Deuterium-fueled DPF at the U.S. Department of Energy’s Nevada National Security Site and show that we can infer the time-energy spectrum from our measurements for both single and multi-pinch fusion reactions with equal fidelity.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A seamless acquisition digital storage oscilloscope with three-dimensional waveform display

In traditional digital storage oscilloscope (DSO), sampled data need to be processed after each acquisition. During data processing, the acquisition is stopped and oscilloscope is blind to the input signal. Thus, this duration is called dead time. With the rapid development of modern electronic systems, the effect of infrequent events becomes significant. To capture these occasional events in shorter time, dead time in traditional DSO that causes the loss of measured signal needs to be reduced or even eliminated. In this paper, a seamless acquisition oscilloscope without dead time is proposed. In this oscilloscope, three-dimensional waveform mapping (TWM) technique, which converts sampled data to displayed waveform, is proposed. With this technique, not only the process speed is improved, but also the probability information of waveform is displayed with different brightness. Thus, a three-dimensional waveform is shown to the user. To reduce processing time further, parallel TWM which processes several sampled points simultaneously, and dual-port random access memory based pipelining technique which can process one sampling point in one clock period are proposed. Furthermore, two DDR3 (Double-Data-Rate Three Synchronous Dynamic Random Access Memory) are used for storing sampled data alternately, thus the acquisition can continue during data processing. Therefore, the dead time of DSO is eliminated. In addition, a double-pulse test method is adopted to test the waveform capturing rate (WCR) of the oscilloscope and a combined pulse test method is employed to evaluate the oscilloscope's capture ability comprehensively. The experiment results show that the WCR of the designed oscilloscope is 6 250 000 wfms/s (waveforms per second), the highest value in all existing oscilloscopes. The testing results also prove that there is no dead time in our oscilloscope, thus realizing the seamless acquisition.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Unravelling the radiation-induced redox chemistry of plutonium ions in aqueous solution

Plutonium plays a critical role in nuclear fuel cycle technologies, but our understanding of its fundamental radiation-induced redox chemistry is limited. Changes in oxidation states affect the speciation and transport of plutonium ions in solution. For example, solvent extraction techniques used to separate and recover plutonium from used nuclear fuel rely on the selective formation, maintenance, and complexation of specific plutonium oxidation states. However, radiolytically generated radicals, ions, and molecules can drive the oxidation state distribution of plutonium ions far from equilibrium, ultimately changing the physical and chemical properties of the bulk system. These radiation-induced processes are inevitable due to the ionizing radiation fields generated by the radioactive decay of plutonium and its daughter nuclides. Therefore, mechanistically understanding how plutonium's various oxidation states respond to ionizing radiation is essential for predicting its behavior in solution. Here, we present significant advances in our understanding of radiation-induced plutonium redox chemistry by using time-resolved (electron pulse) and dose accumulation (alpha and gamma) irradiation techniques, along with quantitative multiscale modeling methods.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Calculation of the cross and auto power spectral densities for low neutron counting from pulse mode detectors

Here, this report introduces a methodology to calculate the prompt neutron decay constant of a subcritical assembly from the cross and auto power spectral densities of detectors operating in pulse mode when the neutron counting is low. The pulse operation mode allows the easy discrimination of the gamma contribution to the detector signal by the pulse height or shape techniques. The methodology is based on a MATLAB script that allows to change arbitrary parameters at any time after the experiment is performed. This technique requires list mode data and is much more flexible than programming the digital acquisition system because in the latter case the arbitrary parameters are set prior to the experiment and cannot be changed any longer after the experiment is performed. The MATLAB script processes all the detectors timestamps from several thousand pulses of the particle accelerator and redistributes them into a time interval that spreads over only 10 particle accelerator pulses. This pulses collapsing procedure has been performed because of the low neutron counting.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Computational and experimental characterization of high-brightness beams for femtosecond electron imaging and spectroscopy

Using a multilevel fast multipole method, coupled with the shadow imaging of femtosecond photoelectron pulses for validation, we quantitatively elucidate the photocathode, space charge, and virtual cathode physics, which fundamentally limit the spatiotemporal and spectroscopic resolution and throughput of ultrafast electron microscope (UEM) systems. We present a simple microscopic description to capture the nonlinear beam dynamics based on a two-fluid picture and elucidate an unexpected dominant role of image potential pinning in accelerating the emittance growth process. These calculations set theoretical limits on the performance of UEM systems and provide useful guides for photocathode design for high-brightness electron beam systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Active Interrogation Using Electronic Neutron Generators for Nuclear Safeguards Applications

Active interrogation, a measurement technique which uses a radiation source to probe materials and generate unique signatures useful for characterizing those materials, is a powerful tool for assaying special nuclear material. The most commonly used technique for performing active interrogation is to use an electronic neutron generator as the probe radiation source. Exploiting the unique operating characteristics of these devices, including their monoenergetic neutron emissions and their ability to operate in pulsed modes, presents a number of options for performing prompt and delayed signature analyses using both photon and neutron sensors. A review of literature in this area shows multiple applications of the active neutron interrogation technique for performing nuclear nonproliferation measurements. Some examples include measuring the plutonium content of spent fuel, assaying plutonium residue in spent fuel hull claddings, assaying plutonium in aqueous fuel reprocessing process streams, and assaying nuclear fuel reprocessing facility waste streams to detect and quantify fissile material. This paper discusses the historical use of this technique and examines its context within the scope and challenges of next-generation nuclear fuel cycles and advanced concept nuclear fuel cycle facilities.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Simulations of radiation damage as a function of the temporal pulse profile in femtosecond X-ray protein crystallography

Serial femtosecond X-ray crystallography of protein nanocrystals using ultrashort and intense pulses from an X-ray free-electron laser has proved to be a successful method for structural determination. However, due to significant variations in diffraction pattern quality from pulse to pulse only a fraction of the collected frames can be used. Experimentally, the X-ray temporal pulse profile is not known and can vary with every shot. This simulation study describes how the pulse shape affects the damage dynamics, which ultimately affects the biological interpretation of electron density. The instantaneously detected signal varies during the pulse exposure due to the pulse properties, as well as the structural and electronic changes in the sample. Here ionization and atomic motion are simulated using a radiation transfer plasma code. Pulses with parameters typical for X-ray free-electron lasers are considered: pulse energies ranging from 10 4 to 10 7 J cm -2 with photon energies from 2 to 12 keV, up to 100 fs long. Radiation damage in the form of sample heating that will lead to a loss of crystalline periodicity and changes in scattering factor due to electronic reconfigurations of ionized atoms are considered here. The simulations show differences in the dynamics of the radiation damage processes for different temporal pulse profiles and intensities, where ionization or atomic motion could be predominant. Overall, the different dynamics influence the recorded diffracted signal in any given resolution and will affect the subsequent structure determination.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Fast-Neutron Multiplicity Counter for the Detection of Diversion Scenarios

We demonstrated the application of a fast-neutron multiplicity counter (FNMC) to detect small variations in an assembly of uranium-oxide pins. The current version of the FNMC includes eight liquid organic scintillators (EJ-309 7.62 cm diameter x 7.62 cm) and eight crystal organic scintillators (stilbene 5.08 cm diameter x 5.08 cm) in a checkerboard assembly. We measured time-correlated fast neutrons, emitted by an assembly of 32 uranium-oxide pins, using two AmLi sources to induce fissions in the sample. Each pin is a cylinder of approximately 1 cm diameter and 10 cm length, with a mass of 75.52 g and 16.37 wt% enrichment. We removed up to 16 pins from a sample consisting of 32 pins, and determined the minimum number of pins that resulted in a statistically significant decrease of neutron coincidence counts. All the measurements were performed at the Zero Power Physics Reactor facility of Idaho National Laboratory. We found that a diversion of the four innermost pins could be detected by the system in 5 minutes. The detection of time-correlated neutrons requires their discrimination from gamma-ray events. This is an especially challenging task when measuring uranium isotopes, because of the intense gamma-ray flux generated by the radioactive decay of uranium daughters. We will describe the on-board pulse shape discrimination and post processing techniques that we applied to effectively distinguish neutrons from gamma-rays. Fast-neutron measurements have several potential advantages compared to thermal and epithermal neutron counters, the most important being a shorter die-away time and therefore reduced spurious coincidences due to accidental counts. This advantage may result in a higher sensitivity in timely detecting diversion of nuclear material from peaceful uses.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Active Interrogation Using Electronic Neutron Generators for Nuclear Safeguards Applications

Active interrogation, a measurement technique which uses a radiation source to probe materials and generate unique signatures useful for characterizing those materials, is a powerful tool for assaying special nuclear material. The most commonly used technique for performing active interrogation is to use an electronic neutron generator as the probe radiation source. Exploiting the unique operating characteristics of these devices, including their monoenergetic neutron emissions and their ability to operate in pulsed modes, presents a number of options for performing prompt and delayed signature analyses using both photon and neutron sensors. A review of literature in this area shows multiple applications of the active neutron interrogation technique for performing nuclear nonproliferation measurements. Some examples include measuring the plutonium content of spent fuel, assaying plutonium residue in spent fuel hull claddings, assaying plutonium in aqueous fuel reprocessing process streams, and assaying nuclear fuel reprocessing facility waste streams to detect and quantify fissile material. This paper discusses the historical use of this technique and examines its context within the scope and challenges of next-generation nuclear fuel cycles and advanced concept nuclear fuel cycle facilities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Lidar Mapping and Surveillance of Nuclear Infrastructure

Wear is unavoidable, whether it occurs in a nuclear facility or abridge on the highway its detection is crucial to preventing the failure of a system. While tools capable of detecting localized damage exist, industry lacks methods to evaluate the health of larger infrastructure. Routine inspection of nuclear facilities must be undertaken to ensure the safety of personnel and proper containment of nuclear materials. Most systems in a nuclear facility are designated as radioactive and confined spaces. To constantly monitor such systems in person would be hazardous but with a remote inspection tool it can be done in a safer and easier way. Lidar: Operates by emitting a laser pulse and looking for the reflected light. Allows user to gain 3D information of the environment. Project Objective: To develop an inspection tool for evaluating the health of large scale infrastructure using Lidar and machine learning. Autonomous Platform + Lidar + Data Fusion + Big Data. Use SLAM to build a 2D map of the environment. Point cloud created by transforming the points between reference frames. Point cloud to Surface: Inherent representation of surface geometry; Difficult to process with conventional techniques. Point cloud to Image: Easily processed by conventional machine learning algorithms. The quantity of data generated will necessitate a big data framework to manage the data for processing. Additional Sensors: Detecting the temperature (a) chemical makeup (b) and radiation emission (c) of a surface could assist in detecting problems. Human inspection can detect irregularities in both physical objects and their point-cloud representations. This is a good indication that mapping nuclear sites using Lidar will provide qualitative insight into the health of the facility. If deep learning can be used to automatically identify problem areas then the completed tool could become an invaluable asset.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Process-driven roadmap for depositing super duplex stainless steel via wire Arc additive manufacturing

Here, this study systematically investigates the effects of shielding gas, bead spacing, weld mode, and travel speed on the phase balance, porosity, and hardness of wire arc additively manufactured (WAAM) super duplex stainless steel (ER2594). Robotic WAAM was employed to fabricate multilayer walls under systematically varied process conditions, followed by phase transformation simulations, X-ray computed tomography (XCT), electron backscatter diffraction (EBSD), and microhardness evaluation. Thermodynamic simulations predicted rapid cooling of AM process can suppress the potential formation of deleterious precipitates which was later validated via cross-sectional microstructure analyses of printed samples. XCT revealed porosity levels below 0.2% for all deposits, with reduced travel speed significantly lowering defect volume. Microstructural analyses revealed the evolution of various austenite precipitates, including grain boundary austenite (GBA), Widmanstätten austenite (WA), and intergranular austenite (IGA), sequentially upon cooling of the ferrite phase. Among all process parameters, weld transfer mode exhibited the strongest influence on phase balance; pulsed mode promoted higher ferrite retention (~ 36%) compared to RapidX mode. No consistent relationship between stabilized phase fraction and captured microhardness was observed. This work provides critical insights for optimizing WAAM parameters to control phase balance and mechanical performance, which is essential for producing high-integrity super duplex stainless-steel components for nuclear and marine applications.

Grain orientation↗

Uncovering the Functional Role of Coherent Phonons during the Photoinduced Phase Transition in a Molecular Crystal

The atomic motions that make up phonons and molecular vibrations in molecular crystals influence their photophysical and electronic properties, including polaron formation, carrier mobility, and phase transitions. Discriminating between spectator and driving motions is a significant challenge hindering optimization. Unlocking this information and developing fine-tuned controls over actively participating phonon modes would not only lead to a stronger understanding of photochemistry but also provide a significant new tool in controlling solid state chemistry. We present a strategy using rationally designed double pulses to unveil the unique function of specific excited state phonon modes. Using ultrafast spectroscopy, we identified 50 and 90 cm –1 phonons involved in modulating the photoinduced spin-Peierls melting of potassium tetracyanoquinodimethane crystals. Here, we show that the 50 cm –1 phonon specifically corresponds to the coherent nuclear wavepacket involved in the charge transfer component of the overall spin-Peierls phase melting process, while the 90 cm –1 phonon facilitates the phase transition component.

74 ATOMIC AND MOLECULAR PHYSICS↗

Novel high power impulse magnetron sputtering enhanced by an auxiliary electrical field

The high power impulse magnetron sputtering (HIPIMS) technique is a novel highly ionized physical vapor deposition method with a high application potential. However, the electron utilization efficiency during sputtering is rather low and the metal particle ionization rate needs to be considerably improved to allow for a large-scale industrial application. Therefore, we enhanced the HIPIMS technique by simultaneously applying an electric field (EF-HIPIMS). The effect of the electric field on the discharge process was studied using a current sensor and an optical emission spectrometer. Furthermore, the spatial distribution of the electric potential and electric field during the EF-HIPIMS process was simulated using the ANSYS software. The results indicate that a higher electron utilization efficiency and a higher particle ionization rate could be achieved. The auxiliary anode obviously changed the distribution of the electric potential and the electric field in the discharge region, which increased the plasma density and enhanced the degree of ionization of the vanadium and argon gas. Vanadium films were deposited to further compare both techniques, and the morphology of the prepared films was investigated by scanning electron microscopy. The films showed a smaller crystal grain size and a denser growth structure when the electric field was applied during the discharge process.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Digitized two-parameter spectrometer for neutron-gamma mixed field

This paper shows the results of digital processing of output pulses from combined photon-neutron detector using a commercially available digitizer ACQUIRIS DP 210. The advantage of digital processing is reduction of the apparatus in weight and size, acceleration of measurement, and increased resistance to pile-up of pulses. The neutron and photon spectrum of radionuclide source {sup 252}Cf is presented. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Signal-Inducing Bone Cement for Magnetic Resonance Imaging-Guided Spinal Surgery Based on Hydroxyapatite and Polymethylmethacrylate

The aim of this study was to develop a signal-inducing bone cement for magnetic resonance imaging (MRI)-guided cementoplasty of the spine. This MRI cement would allow precise and controlled injection of cement into pathologic lesions of the bone. We mixed conventional polymethylmethacrylate bone cement (PMMA; 5 ml methylmethacrylate and 12 g polymethylmethacrylate) with hydroxyapatite (HA) bone substitute (2-4 ml) and a gadolinium-based contrast agent (CA; 0-60 {mu}l). The contrast-to-noise ratio (CNR) of different CA doses was measured in an open 1.0-Tesla scanner for fast T1W Turbo-Spin-Echo (TSE) and T1W TSE pulse sequences to determine the highest signal. We simulated MRI-guided cementoplasty in cadaveric spines. Compressive strength of the cements was tested. The highest CNR was (1) 87.3 (SD 2.9) in fast T1W TSE for cements with 4 {mu}l CA/ml HA (4 ml) and (2) 60.8 (SD 2.4) in T1W TSE for cements with 1 {mu}l CA/ml HA (4 ml). MRI-guided cementoplasty in cadaveric spine was feasible. Compressive strength decreased with increasing amounts of HA from 46.7 MPa (2 ml HA) to 28.0 MPa (4 ml HA). An MRI-compatible cement based on PMMA, HA, and CA is feasible and clearly visible on MRI images. MRI-guided spinal cementoplasty using this cement would permit direct visualization of the cement, the pathologic process, and the anatomical surroundings.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

BoxScore - A real-time beam-diagnosis program for the CAEN digitizer x730 series

BoxScore is a real-time beam diagnosis and monitoring program for the CAEN x730 series digitizer, developed for the ATLAS in-flight system at Argonne National Laboratory. The CAEN x730 series digitizer, with built-in Digital Pulse Processing for the Pulse-Height-Analysis, digitizes the input signal in real-time and processes it using a trapezoidal filter. BoxScore reads the digitizer’s buffer directly, builds and saves events to local files, plots histograms for particle identification, and outputs the rates of selected isotopes every second. Implementation of BoxScore has shortened the time needed for in-flight beam-tuning and has potential applications for other nuclear physics experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A digital method for separation and reconstruction of pile-up events in germanium detectors

The problem of pulse pile-up is very often encountered in precise measurements of {gamma}-rays using germanium detectors. The standard method of treating the pile-up events is to identify and reject them using an appropriate electronic system. Digital acquisition techniques now allow the recording of waveforms of pile-up events that can be analyzed and the contributing single pulses recovered, rather than simply tolerating the losses associated with pile-up. In this paper, a method for the off-line digital processing of pile-up events from germanium detectors is demonstrated. The method is based on an appropriate fitting of the detector signals, shaped with a suitable digital pulse shaper. It is shown that the method is able to recover the pile-up events with good accuracy even when the constituent signals are in close proximity. The method is very useful for {gamma}-ray spectroscopy in nuclear physics experiments, where the low intensity signals can be lost due to the pile-up in a high-rate environment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

AWE neutron spectrometry results from Godiva-IV (NCERC) characterization - Paper 135

In recent years, it was deemed necessary for the Godiva-IV critical assembly - along with other assemblies collectively forming what is now known as the National Critical Experiments Research Center (NCERC) - to relocate to the Device Assembly Facility (DAF) at the Nevada National Security Site (NNSS). An experiment was proposed (IER-148) under the Nuclear Criticality Safety Program for an international inter-comparison of Nuclear Accident Dosimetry (NAD) using the Godiva-IV assembly, in order to arrest the long term decline in the testing and validation of these systems. Due to the knock-on effect of the change of location on the neutron leakage spectrum, however, new reference points must be established. As a precursor to the intercomparison an additional experiment (IER-147) was proposed with the aim of measuring these reference values for the current Godiva-IV radiation field in the DAF. To establish the reference values Godiva was run in both a sub-critical steady-state mode and a super prompt-critical, pulsed mode. AWE provided neutron spectrometry capabilities in the form of a ROSPEC and Bonner sphere Spectrometer (BSS) for the steady-state experiment, and a Passive Bonner sphere Spectrometer (PBSS) for the pulsed experiment. Neutron leakage spectrum measurements carried out by AWE have been used to determine reference doses around Godiva which can be used for future NAD inter-comparisons. A good comparison of steady-state and pulsed spectra indicates a strong likelihood of being able to relate the power level of both operational methods of the reactor for future work in other fields. Further work is required to determine the fidelity of the thermal peak and it is the intention of AWE to bring additional thermal information to the unfolding process through the incorporation of supplementary activation foils used in the irradiations. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗