Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “multiple sensors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Simulations of Sparse Static Detector Networks for City-Scale Radiological/Nuclear Detection

Sparse static detector networks in urban environments can be used in efforts to detect illicit radioactive sources, such as stolen nuclear material or radioactive "dirty bombs." We use detailed simulations to evaluate multiple configurations of detector networks and their ability to detect sources moving through a $6\times 6$ km 2 area of downtown Chicago. A detector network's probability of detecting a source increases with detector density but can also be increased with strategic node placement. Here, we show that the ability to fuse correlated data from a source-carrying vehicle passing by multiple detectors can significantly contribute to the overall detection probability. In this article, we distinguish static sensor deployments operated as networks able to correlate signals between sensors, from deployments operated as arrays where each sensor is operated individually. In particular, we show that additional visual attributes of source-carrying vehicles, such as vehicle color and make, can greatly improve the ability of a detector network to detect illicit sources.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Non-contact Current-Voltage (I-V) Tracer for Photovoltaics

This report presents a non-contact approach to simultaneously obtain current-voltage (I-V) curves of photovoltaic (PV) substrings and modules in a string without the need of disconnecting the individual modules from the string. There are two types of I-V curve tracers currently available in the marketplace, capacitor-based and electronic load-based. The primary requirement of these conventional I-V tracers is the disconnection of individual modules in the string so the individual modules contacted through the connectors of the individual modules. These contact-tracers have three major limitations in the utility scale power plants: First limitation – Weather and Accuracy: The mass-produced commercial contact-tracers cannot obtain the I-V curves of both string and its modules (as high as 30 modules), almost simultaneously (within about 5 minutes) at, practically, a single irradiance level, a single module temperature, a single spectrum and a single AOI (angle of incidence). This inability of the contact-tracers forces the testing personnel to wait for an extended or multiple sunny (>800 W/m 2 ) duration(s) of a cloudy day. This is a serious limitation as waiting for the sunny conditions or days is a huge practical challenge in almost all locations, except desert locations. Also, since the I-V curves are obtained at different prevailing weather conditions, it becomes critical to translate all the measured I-V curves of 30 modules in the string to a single test condition, for example STC (standard test conditions), so the underperforming modules can be identified. The accuracy of translation equations is heavily influenced by the irradiance level and temperature, spectral and AOI ranges; Second limitation - Safety: The second limitation is related to the high voltage electrical safety of the test personnel during disconnecting and reconnecting of individual modules or cable connectors from the string under daylight conditions and damaging of the original module connectors (especially the field aged connectors) during the disconnecting and reconnecting process; Third limitation – Labor: The third limitation is related to the enormous amount of time and hardship for the test personnel under prevailing (often harsh) protracted field conditions. This project was executed by Arizona State University in collaboration with its industry partner, PV Measurements Inc. (PVM). To mitigate all the three challenges of the state-of-the-art equipment indicated above, we utilized a non-contact I-V (NCIV) tracer approach. In this approach, we utilized an electrostatic voltmeter (ESV) and voltage sensor/probe combination to obtain I-V curves. The ESV units are extensively used in the high voltage industry but not in the PV industry. To obtain the simultaneous I-V curves of the substrings and modules within a string, we utilized multiple commercial ESV-Probe sets. In this approach, we utilized a non-contact voltage sensor (called, Probe) placed on the glass surface of the module (above the last cell of the module). This probe senses the module voltage (with respect to ground) through measured capacitance which is dictated by the surface charges (which in turn is dictated by the module voltage) and transmits the sensed voltage to the voltmeter (called, ESV or NCV, non-contact voltmeter). The current is sensed by a non-contact hall sensor. In a 30-module string, the 30th probe obtains the entire string I-V along with the string I-V obtained by the electronic load. so that the I-V curves of the substrings and modules can be obtained by NCIV without the need of disconnecting the individual modules in the string. The string I-V curves obtained by the electronic load and NCIV can be compared for the accuracy determination. One can use 30 ESV units and 30 Probes to obtain 30 I-V curves of a 30-module string or use just 5 ESV units and 30 Probes in conjunction with 5 six-channel switchboxes (called, 6:1 switchboxes). To reduce the equipment cost, we utilized the 6:1 switchbox approach so the number of ESV units is reduced from 30 to 5. The approaches, achievements and challenges of this project are detailed in this report.

14 SOLAR ENERGY↗

Standoff Detection of Chemical Plumes Using Swept-ECQCL Remote Detection Technology: Results from EMRTC Complex Terrain Dual Tracer Experiment

As part of the Complex Terrain Dual Tracer Experiments performed in support of the LYNM program, a swept-wavelength external cavity quantum cascade laser (swept-ECQCL) remote detection system was deployed to measure chemical plume propagation with high temporal resolution. The swept-ECQCL remote detection technology was initially developed at PNNL, and is now under further development at Opticslah, LLC under SBIR funding from DOE (DOE SBIR Phase I Project DE-SC0019855, Remote Detection Technologies, Program Manager Chris Ramos). The swept-ECQCL technology provides a single-frequency infrared laser source which is rapidly scanned over a large wavelength range to measure the infrared absorption of gases, liquids, or solids. Analysis of the measured infrared absorption spectrum is used to detect, identify, and quantify the chemical species which are present. While most previous laser-based techniques used small wavelength tuning ranges to measure only a few isolated spectral lines of a few species, the swept-ECQCL provides the large tuning range needed to measure multiple species simultaneously, and to detect broad absorption features from large molecules or condensed phase materials. In addition, the swept-ECQCL systems have high enough spectral resolution and sensitivity to measure narrow lines of small molecules and determine isotope ratios. The remote detection system for gas plumes is based on the swept-ECQCL technology, and consists of a swept-ECQCL source, infrared detector, control electronics, and beam transmitting and alignment optics. The remote detection system directs the infrared output of the swept-ECQCL to a target retro reflector typically located at ~10-10,000 m distance. The swept-ECQCL wavelength is varied continuously over a large wavelength range (>1000 nm) at rates up to 1000 Hz. The swept ECQCL light reflected from the remote target is collected and focused onto an infrared photodetector. By measuring the detector signal continuously as the swept-ECQCL wavelength is varied, a time-series of absorption spectra are measured for the gases along the beam line of-sight. Based on analysis and fitting of the measured absorption spectra, the time-dependent chemical concentrations of species are determined. Multiple species and mixtures can be detected simultaneously, for all species with absorption features above the sensor noise floor. The sensor output is thus a continuous, high-speed record of identified chemicals along with their concentrations and isotope ratios of interest. The high-speed operation enables low-noise operation in conditions of atmospheric turbulence and allows tracking of fluctuating concentrations in transient chemical plumes as needed for reliable remote detection applications. All components operate with minimal cooling requirements and no cryogens are needed. In addition, the output infrared light is invisible with an intensity below the maximum permissible exposure (MPE) threshold of 100 mW/cm2 for these infrared wavelengths and thus eye safe. The measurement concept for plume detection using the swept-ECQCL remote detection system is as follows. The ECQCL beam is directed toward a remote retro-reflector, which reflects the beam back to the ECQCL system where it is focused onto an infrared photodetector. The line-of-sight from the ECQCL system to the retro-reflector defines the measurement path. The detected infrared signal is recorded continuously and detects the absorption of molecular species along the measurement path. Before a plume release, the system measures absorption from atmospheric constituents, which in this LWIR band consist primarily of lines from H 2 O and CO 2 , with additional weaker absorption from N 2 O, NH 3 , and O 3 possibly contributing. The system then measures any changes in absorption due to the tracer compounds when they enter the measurement path. The shape of absorption features is used to distinguish and identify the different tracer compounds, and the strength of the absorption is used to determine the path-integrated concentration – also called the column density.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Gumby: Quantifying multi-modal model resiliency

With the rise of cheap data and sensors, more use cases are emerging for multi-input models. Research has shown that including multiple data modalities can improve performance, suggesting that deep learning models can successfully learn to leverage complementary information from different modalities. However, this improved predictive power comes with unanticipated costs: additional inputs change model resiliency and expand the threat space for adversarial attacks. We first provide theoretical underpinnings for how adversarial success scales with input dimension. We then characterize the performance of a suite of multispectral deep learning models with different fusion approaches, quantify their relative reliance on different input bands, and evaluate their robustness to naturalistic and adversarial image corruptions.

97 MATHEMATICS AND COMPUTING↗

Microfluidic systems, pumps, valves, fluidic chips thereof, and applications of same

Microfluidic systems, pumps, valves and applications of the same are provided. The microfluidic system may be a pump or a valve having a fluidic chip and an actuator controlling the opening and closing of the fluidic channel in the fluidic chip. The actuator may be disposed to tilt from the fluidic chip, forming a tilted-rotor peristaltic pump. Alternatively, the actuator may be a rolling ball actuator, and different fluidic chips may be used in different applications. For example, the fluidic chip may be a spiral pump chip having spiral channels, a rotary peristaltic pump chip having multiple output channels, or a multi-port valve chip having one port interconnected with multiple different ports. An analytical valve chip may switchably interconnect bioreactor and rinse/calibration input channels to sensor and waste output channels. The actuator of a random-access valve can move from one valve position to another without opening or closing intermediate ones.

Reiserer, Ronald S.↗

Microfluidic systems, pumps, valves, fluidic chips thereof, and applications of same

Microfluidic systems, pumps, valves and applications of the same are provided. The microfluidic system may be a pump or a valve having a fluidic chip and an actuator controlling the opening and closing of the fluidic channel in the fluidic chip. The actuator may be disposed to tilt from the fluidic chip, forming a tilted-rotor peristaltic pump. Alternatively, the actuator may be a rolling ball actuator, and different fluidic chips may be used in different applications. For example, the fluidic chip may be a spiral pump chip having spiral channels, a rotary peristaltic pump chip having multiple output channels, or a multi-port valve chip having one port interconnected with multiple different ports. An analytical valve chip may switchably interconnect bioreactor and rinse/calibration input channels to sensor and waste output channels. The actuator of a random-access valve can move from one valve position to another without opening or closing intermediate ones.

Reiserer, Ronald S.↗

Tunneling Barrier-Integrated Gold Nanofilms for Negative Strain Gauging with Near-Zero Energy Consumption

Wireless strain sensors with minimal power needs are essential for long-term monitoring in energy-limited environments. We present a soft tunneling barrier-integrated gold thin film for negative strain sensing with near-zero energy consumption. The device features a strain-induced transition from an insulating to a metallic state, increasing conductivity by 9 orders of magnitude under a controlled strain. It consists of Au-PDMS-Au nanofilm layers, where the Au structures are near the percolation threshold and the PDMS layer acts as a tunneling barrier. Under strain, thinning due to the Poisson effect lowers the barrier’s potential height, enabling electron tunneling and forming an electrical path. Further, with a standby power consumption of ~10 –5 mW over 10 6 times lower than conventional sensors (~12.5 mW), this device is ideal for real-time, long-term stationary structural monitoring in multiple locations.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

A scanning resonator for probing quantum coherent devices

Superconducting resonators with high quality factors are extremely sensitive detectors of the complex impedance of materials and devices coupled to them. This capability has been used to measure losses in multiple different materials and, in the case of circuit quantum electrodynamics (circuit QED), has been used to measure the coherent evolution of multiple different types of qubits. Here, we report on the implementation of a scanning resonator for probing quantum coherent devices. Our scanning setup enables tunable coherent coupling to systems of interest without the need for fabricating on-chip superconducting resonators. We measure the internal quality factor of our resonator sensor in the single-photon regime to be >104 and demonstrate capacitive imaging using our sensor with zeptoFarad sensitivity and micron spatial resolution at milliKelvin temperatures. We then use our setup to characterize the energy spectrum and coherence times of multiple transmon qubits with no on-chip readout circuitry. Our experiments introduce a new tool for using circuit QED to measure existing and proposed qubit platforms.

47 OTHER INSTRUMENTATION↗

Pilot-Scale Validation of Distributed Optical Fiber Sensors for Underground Pipeline Monitoring

Monitoring parameters such as hoop strain, pressure, and acoustic vibrations is key to detecting potential leaks, intrusions, or structural issues. Distributed optical fiber sensor (DOFS) systems provide a compelling solution for continuous, real-time monitoring over long distances. This paper details the development and pilot-scale implementation of DOFS systems for underground pipeline monitoring, evolving from a proof-of-concept stage. Multiple custom-designed DOFS interrogator units—such as optical frequency-domain reflectometry (OFDR), Brillouin optical time-domain analysis (BOTDA), and multimodal interferometer-based fiber acoustic sensor systems were tested to measure the key parameters, such as hoop strain, pipe pressure, surrounding soil temperature, and acoustic vibrations. The underground product pipeline’s outer diameter is 30 inches, the wall thickness is 1.28 inches, and 3 feet deep from the surface. The fiber deployment strategies and sensing data acquisition methods for these systems are discussed. The results demonstrate the effectiveness of DOFS in detecting hoop strain, temperature changes, and acoustic vibrations, showcasing their potential for real-time monitoring and enhancing pipeline safety. These findings from pilot-scale testing offer valuable insights into advancing pipeline monitoring technologies and improving the reliability of underground pipeline systems.

fiber optic sensors↗

Pilot-Scale Validation of Distributed Optical Fiber Sensors for Underground Pipeline Monitoring

Distributed fiber optic sensing is a cutting-edge technology that has found extensive applications in the monitoring of Ensuring the safety, integrity, and operational efficiency of underground product pipelines is vital for maintaining the nation’s critical infrastructure. Monitoring parameters such as hoop strain, pressure, and acoustic vibrations is key to detecting potential leaks, intrusions, or structural issues. Distributed optical fiber sensor (DOFS) systems provide a compelling solution for continuous, real-time monitoring over long distances. This paper details the development and pilot-scale implementation of DOFS systems for underground pipeline monitoring, evolving from a proof-of-concept stage. Multiple custom-designed DOFS interrogator units—such as optical frequency-domain reflectometry (OFDR), Brillouin optical time-domain analysis (BOTDA), and multimodal interferometer-based fiber acoustic sensors—were employed to measure key parameters like hoop strain, pressure, and acoustic vibrations. The underground product pipeline's outer diameter is 30 inches, the wall thickness is 1.28 inches, and the 3-foot depth. The fiber deployment strategies, and sensing data acquisition methods for these systems are discussed. The results demonstrate the effectiveness of DOFS in detecting hoop strain, temperature changes, and acoustic vibrations, showcasing their potential for real-time monitoring and enhancing pipeline safety.

distributed fiber sensing↗

Unified Software Architecture for Advanced Materials and Manufacturing Technologies Data Management and Processing: FY 2023 Multidimensional Data Correlation Platform

This report details the various digital manufacturing activities ongoing at ORNL as part of the Advanced Materials and Manufacturing Technologies (AMMT) program. The AMMT program is exploring a data-driven approach to demonstrate the use of AM for the fabrication of components for nuclear applications, with the goal of providing a greater understanding of manufacturing quality outcomes that would pave the way toward the development of standards for certification and qualification. The objective of this work package is to establish a digital manufacturing discipline common to all participants of the AMMT program to improve the performance, reliability, and lifetime of nuclear components. As part of this effort, we will develop a unified software architecture for AMMT data management and processing, deploy the digital platform across AMMT participants’ facilities, and generate pedigreed datasets in a common format across multiple labs and facilities. To this end, the MDDC work package has focused on three activities during FY23. First, the MDF Digital Tool was overhauled to better serve the needs of the AMMT program. Next, multiple laser powder bed fusion (L-PBF) systems at the MDF were upgraded to a common sensor package for collecting comparable in situ data across machines. Finally, various improvements relevant to the AMMT program were implemented in the ORNL-developed software tool, Peregrine. This report marks the completion of FY23 milestone M3CR-22OR0403051: Report Describing the Architecture of the Digital Platform to Support AMMT Activities.

36 MATERIALS SCIENCE↗

A graph signal processing‐based multiple model Kalman filter ( GSP‐MMKF ) tool for predictive analytics: An air separation unit process application

Abstract The industrial Air Separations Unit (ASU) is a complicated and tightly operated process. The use of dynamic process analytics is also a key element of safe and economic operation of these processes, with increasing focus on predictive analytics to take preemptive actions. With the availability of real‐time data from hundreds of sensors, the data analysis process should also consider the topology of the data, as seen in sensor networks. In this paper, a novel tool is presented that considers the complex connectivity patterns in the sensor network and uses local adaptive disturbance estimations to predict global network‐scale trends. The paper introduces the emerging field of Graph Signal Processing (GSP) and presents a rigorous derivation of the tool starting from the extraction of the sensor‐network (in a graph theoretical sense) from the data. This network, which is in the form of a matrix, is then used to derive a Kalman‐filter type of state‐space model driven by input disturbances. Multiple disturbance models (e.g., step, ramp, periodic) are included to allow the model to have different kinds of disturbance propagation. Each graph node (representing the sensors used) dynamically adapts to the most recent detected disturbance individually. These estimated disturbances are propagated to the global network using the graph. Modifications to ensure stability are also discussed. The fidelity of the tool is tested on certain downtime events and the paper concludes by discussing the advantages of the method and planned future improvements.

Ghosh, Sambit↗

Structural response reconstruction using a system-equivalent singular vector basis

Here, this paper develops a novel method for reconstructing the full-field response of structural dynamic systems using sparse measurements. The singular value decomposition is applied to a frequency response matrix relating the structural response to physical loads, base motion, or modal loads. The left singular vectors form a non-physical reduced basis that can be used for response reconstruction with far fewer sensors than existing methods. The contributions of the singular vectors to measured response are termed singular-vector loads (SVLs) and are used in a regularized Bayesian framework to generate full-field response estimates and confidence intervals. The reconstruction framework is applicable to the estimation of single data records and power spectral densities from multiple records. Reconstruction is successfully performed in configurations where the number of SVLs to identify is less than, equal to, and greater than the number of sensors used for reconstruction. In a simulation featuring a seismically excited shear structure, SVL reconstruction significantly outperforms modal FRF-based reconstruction and successfully estimates full-field responses with as few as two uniaxial accelerometers. SVL reconstruction is further verified in a simulation featuring an acoustically excited cylinder. Finally, response reconstruction and uncertainty quantification are performed on an experimental structure with three shaker inputs and 27 triaxial accelerometer outputs.

42 ENGINEERING↗

Manipulating polymer composition to create low-cost, high-fidelity sensors for indoor CO2 monitoring

Abstract Carbon dioxide (CO 2 ) has been linked to many deleterious health effects, and it has also been used as a proxy for building occupancy measurements. These applications have created a need for low-cost and low-power CO 2 sensors that can be seamlessly incorporated into existing buildings. We report a resonant mass sensor coated with a solution-processable polymer blend of poly(ethylene oxide) (PEO) and poly(ethyleneimine) (PEI) for the detection of CO 2 across multiple use conditions. Controlling the polymer blend composition and nanostructure enabled better transport of the analyte gas into the sensing layer, which allowed for significantly enhanced CO 2 sensing relative to the state of the art. Moreover, the hydrophilic nature of PEO resulted in water uptake, which provided for higher sensing sensitivity at elevated humidity conditions. Therefore, this key integration of materials and resonant sensor platform could be a potential solution in the future for CO 2 monitoring in smart infrastructure.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Characterization and Analysis of the Energy-Reporting Accuracy of Connected Devices

Emerging energy-efficient building systems increasingly exhibit greater functionality, often requiring multiple operating modes (e.g. white-tunability for lighting products and data traffic for devices with networked, integrated sensors). This increased functionality makes energy consumption estimates more complex. Given that these functions consume energy, the energy performance of such building systems is dependent on what operating modes they use and how much time they spend in each mode. Devices and systems that can report their own energy consumption mitigate this energy-performance uncertainty. This study explores the energy-reporting accuracy of market-available connected electrical outlets. The study considers two residential-market products (five units each, one outlet per unit) and three commercial-market products (two units each, 18 to 24 outlets per unit) with the ability to report power drawn and/or energy consumed by devices connected to their receptacles. The products were purchased through typical market channels. Pacific Northwest National Laboratory (PNNL) conducted testing in December 2018 at its Connected Lighting Test Bed (CLTB), using a custom-developed test setup and method adapted from industry standards. The setup collected energy-consumption data reported by the outlet devices under test (DUTs) at one-minute intervals and compared that data with measurements taken by a reference meter over a range of test conditions. The residential products reported power draw but not interval or cumulative energy consumption. The commercial products reported both power draw and cumulative energy consumption. Relative reporting error (RRE) was calculated for all measurements, and analysis of the results revealed variations across devices and test conditions. The total number of measurements (50 for each residential product, 60 for each commercial product) offers an appreciable comparison of performance at the make/model level. The average RRE of the residential products derived from reported power draw was -0.02% and -1.20%. The average RRE for two of the three the commercial products derived from reported power draw was worse than those of the residential products (-2.40%, -2.72%, -0.36%). The internal integration of power over time, used to calculate cumulative energy consumption, typically occurs at current and voltage sampling rates much higher than once per minute. This suggests that the average commercial-product RRE derived from reported energy consumption should be very consistent and better than performance based on reported power draw. However, the RRE derived from reported energy consumption varied significantly across the three makes of commercial-market products and was uniformly less accurate than performance based on reported power draw. Subsequent analysis identified a number of root causes for this decrease in performance, most of which were related to reporting resolution. The goals of this study are to generate awareness of building systems capable of reporting their own energy consumption, further interest in the value of energy data for a variety of uses, draw attention to how the accuracy of reported metrics can be characterized, and quantify the performance variation found in marketavailable products. The results of this study and subsequent related work may be relevant to stakeholders in industry-specification and standards-development organizations. The methods this study employs could inform test and measurement procedures and performance classifications for connected outlets, lighting products, and other building systems capable of reporting their own energy consumption. The study concludes with stakeholder recommendations, including the following: • Energy-reporting device and system manufacturers developing products that report energy consumption should characterize the accuracy of reported metrics using a reference meter calibrated by an independent laboratory that was accredited by an ILAC MRA signatory (and whose scope of accreditation explicitly covers energy measurement), and should include this information on product data sheets. • Standards and specification development organizations should develop application-specific performance classifications that end users can understand and relate to their energy-data use needs (e.g., 2% accuracy class for utility streetlight energy billing needs, or 10% accuracy class for ESCO performance verification needs). • Current or potential owners, operators, and specifiers of energy-reporting building systems should rigorously analyze the dependency of current and planned energy-data use cases on accuracy, noting in particular the dependence (or lack thereof) on relative vs. absolute accuracy, and on trueness vs. precision (i.e., repeatability), and should communicate use-case needs to industry standards and specification organizations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Characterization and Analysis of the Energy-Reporting Accuracy of Connected Devices

Emerging energy-efficient building systems increasingly exhibit greater functionality, often requiring multiple operating modes (e.g. white-tunability for lighting products and data traffic for devices with networked, integrated sensors). This increased functionality makes energy consumption estimates more complex. Given that these functions consume energy, the energy performance of such building systems is dependent on what operating modes they use and how much time they spend in each mode. Devices and systems that can report their own energy consumption mitigate this energy-performance uncertainty. This study explores the energy-reporting accuracy of market-available connected electrical outlets. The study considers two residential-market products (five units each, one outlet per unit) and three commercial-market products (two units each, 18 to 24 outlets per unit) with the ability to report power drawn and/or energy consumed by devices connected to their receptacles. The products were purchased through typical market channels. Pacific Northwest National Laboratory (PNNL) conducted testing in December 2018 at its Connected Lighting Test Bed (CLTB), using a custom-developed test setup and method adapted from industry standards. The setup collected energy-consumption data reported by the outlet devices under test (DUTs) at one-minute intervals and compared that data with measurements taken by a reference meter over a range of test conditions. The residential products reported power draw but not interval or cumulative energy consumption. The commercial products reported both power draw and cumulative energy consumption. Relative reporting error (RRE) was calculated for all measurements, and analysis of the results revealed variations across devices and test conditions. The total number of measurements (50 for each residential product, 60 for each commercial product) offers an appreciable comparison of performance at the make/model level. The average RRE of the residential products derived from reported power draw was -0.02% and -1.20%. The average RRE for two of the three the commercial products derived from reported power draw was worse than those of the residential products (-2.40%, -2.72%, -0.36%). The internal integration of power over time, used to calculate cumulative energy consumption, typically occurs at current and voltage sampling rates much higher than once per minute. This suggests that the average commercial-product RRE derived from reported energy consumption should be very consistent and better than performance based on reported power draw. However, the RRE derived from reported energy consumption varied significantly across the three makes of commercial-market products and was uniformly less accurate than performance based on reported power draw. Subsequent analysis identified a number of root causes for this decrease in performance, most of which were related to reporting resolution. The goals of this study are to generate awareness of building systems capable of reporting their own energy consumption, further interest in the value of energy data for a variety of uses, draw attention to how the accuracy of reported metrics can be characterized, and quantify the performance variation found in marketavailable products. The results of this study and subsequent related work may be relevant to stakeholders in industry-specification and standards-development organizations. The methods this study employs could inform test and measurement procedures and performance classifications for connected outlets, lighting products, and other building systems capable of reporting their own energy consumption. The study concludes with stakeholder recommendations, including the following: • Energy-reporting device and system manufacturers developing products that report energy consumption should characterize the accuracy of reported metrics using a reference meter calibrated by an independent laboratory that was accredited by an ILAC MRA signatory (and whose scope of accreditation explicitly covers energy measurement), and should include this information on product data sheets. • Standards and specification development organizations should develop application-specific performance classifications that end users can understand and relate to their energy-data use needs (e.g., 2% accuracy class for utility streetlight energy billing needs, or 10% accuracy class for ESCO performance verification needs). • Current or potential owners, operators, and specifiers of energy-reporting building systems should rigorously analyze the dependency of current and planned energy-data use cases on accuracy, noting in particular the dependence (or lack thereof) on relative vs. absolute accuracy, and on trueness vs. precision (i.e., repeatability), and should communicate use-case needs to industry standards and specification organizations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Integrated Controls Package for High Performance Interior Retrofit [Slides]

For the last few years, networked lighting control (NLCs) have promised significant energy savings beyond what is achieved through a basic light-emitting diode (LED) lighting retrofit. At the same time, NLCs can substantially increase the cost and complexity of the lighting retrofit. And as lighting system wattage declines because of the increasing efficiency of LEDs, advanced controls have less lighting energy to save and the cost-effectiveness of the NLC investment decreases. But NLCs can be leveraged to achieve significant energy savings and value by enhancing control of other building systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗