283 records · Page 16

All Hands On Deck: Raising the Bar on Whole Building Performance-Based Code Compliance and Above-Code Programs

In 2019 a large-scale national effort was launched with support from U.S. Department of Energy, Pacific Northwest National Laboratory and Northwest Energy Efficiency Alliance (NEEA). The project aimed to develop a long-term vision and a roadmap for achieving a practical application of whole building performance-based code and above code program compliance in commercial buildings. The work was aided by engaging over 70 stakeholders across the country representing jurisdictions, above-code programs such as LEED and ENERGY STAR Multifamily Program, members of the ASHRAE Standard 90.1 and other Standard committees, IBPSA and software developers. The performance path requires whole building energy modeling and is gaining momentum. Many see it as the future of the commercial energy codes and the main pathway for achieving zero energy buildings. The paper describes the findings from a stakeholder survey funded by NEEA on the current state of performance-based path, its market penetration, trends, implementation practices and adoption challenges. It discusses the patterns revealed by experience of the states with decades-long history of performance-based compliance such as Florida and California and opportunities for taking advantage of the synergies between code and above-code programs. In addition, the paper provides an overview of the tools and resources developed as part of the effort including the compliance form for ASHRAE Standard 90.1 Section 11 and Appendix G, modeling submittal review manual, and modeler and reviewer qualification requirements. The tools and resources would help remove market barriers, deliver immediate benefits to jurisdictions and rating authorities, and achieve energy efficiency through whole-building performance path.

TSPR, Performance Based Complinace, Washington Sta↗

Standard Work Specifications (SWS)

The SWS are a free online tool and industry guide that defines the minimum acceptable outcomes for home energy upgrades installed on single-family, multifamily, and manufactured housing.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Understanding Building Energy Use in the Greater Memphis Area: Basic Building Stock Characterization

This report is part of a publication series that focuses on approximately 100 different local geographies, or "clusters." Each report provides commercial and multifamily building characteristic and energy data for a local geography, with the intention of helping policymakers at the city, county and state levels better understand building energy use. Specifically, this report breaks down the building stock in the counties shown in Figure 1 by building type, size, energy consumption, and emissions.

building stock↗

Performance Evaluation of Drain Water Heat Recovery Exchangers for Heat Pump Water Heaters

Water heating constitutes approximately 18% of energy consumption and is the second largest energy expenses in United States homes. Heat pump water heaters (HPWHs) are energy efficient technologies with lower carbon footprints as compared to conventional water heating technologies, such as gas and electrical resistance heaters. The performance of water-source HPWHs can be improved by recovering heat from blackwater using drain heat recovery heat exchangers. Depending on water draw patterns of single family and multifamily residences, the operation and heat transfer performance of these heat exchangers are highly transient. This paper examines the thermo-hydraulic performance of a drain heat recovery heat exchanger during its transient and steady-state operations. The heat recovery performance of the exchanger was evaluated at different inlet temperatures and flow rates ranging from 9°C to 36°C and 0.03 kg/s to 0.28 kg/s, respectively. The obtained effectiveness varies from 45%–85% depending on the operating conditions. The test facility, steady-state and transient experimental procedures are reported in detail. Further, the effect of operating conditions on the effectiveness is discussed. The experimental approach and results of the study will provide insights into the transient operation of drain recovery heat exchangers as well as, guide sizing for various steady state conditions.

Krishnan, Easwaran↗

How Heat Pumps Can Bring Relief to Households

An estimated 230,000 low-income households in Los Angeles lack access to cooling and are projected to experience more than two months of dangerous indoor temperatures (above 86 F) by 2035. Multifamily building residents are at much higher risk of dangerous heat exposure. Through robust modeling and analysis in the LA100 Equity Strategies project, the National Renewable Energy Laboratory (NREL) identified strategies that could save lives and maintain safe home temperatures for low-income households during heat waves, including the installation of whole-home heat pumps.

buildings↗

Rewarding Grid-Friendly Behavior: Estimating the Potential Bill Reduction and Load Shifting Benefits of Dynamic Prices

Shifting electric load from times of peak demand can be a key strategy to slow price growth as reducing peak demand avoids the cost of upgrading generation, transmission and distribution infrastructure. Utilities are releasing time-varying prices, such as time of use rates or dynamic prices, to incentivize grid-friendly load shifting. New dynamic price programs provide insight into the true cost of operating electricity grids and the potential economic benefits of load shifting. Program developers and device manufacturers need to understand the economic opportunities in terms of 1) the variation in prices across hours, days, and seasons; 2) the change in utility bills for customers who don’t shift load; and 3) the potential load shifted and economic value of different technologies if manufacturers or aggregators deploy price-responsive controls. This paper estimates possible impacts of dynamic price adoption and load shifting controls if customers paid the dynamic rate from one pilot program. Statistical analysis of historical prices identified annual and seasonal metrics as well as representative price curves for each circuit in the pilot. Simulations for residential technologies with price-responsive controls including unitary heat pump water heaters, central multifamily heat pump water heaters, heating & cooling + storage systems, and pool pumps estimated the potential impacts of highly dynamic prices both with and without load shifting controls. Results showed the potential to reduce electricity costs on representative days by 42-94% and reduce consumption during times of high electricity prices by 63-100% compared to baseline operation for those flex-friendly devices.

Grant, Peter↗

Indoor air quality in new and renovated low-income apartments with mechanical ventilation and natural gas cooking in California

This work presents pollutant concentrations and performance data for code-required mechanical ventilation equipment in 23 low-income apartments at 4 properties constructed or renovated 2013-2017. All apartments had natural gas cooking burners. Occupants pledged to not use windows for ventilation during the study but several did. Measured airflows of range hoods and bathroom exhaust fans were lower than product specifications. Only eight apartments operationally met all ventilation code requirements. Pollutants measured over one week in each apartment included time-resolved fine particulate matter (PM 2.5 ), nitrogen dioxide (NO 2 ), formaldehyde and carbon dioxide (CO 2 ) and time-integrated formaldehyde, NO 2 and nitrogen oxides (NO X ). Compared to a recent study of California houses with code-compliant ventilation, apartments were smaller, had fewer occupants, higher densities, and higher mechanical ventilation rates. Mean PM 2.5 , formaldehyde, NO 2 , and CO 2 were 7.7 µg/m 3 , 14.1 ppb, 18.8 ppb, and 741 ppm in apartments; these are 4% lower, 25% lower, 165% higher, and 18% higher compared to houses with similar cooking frequency. Four apartments had weekly PM 2.5 above the California annual outdoor standard of 12 µg/m 3 and also discrete days above the World Health Organization 24-h guideline of 25 µg/m 3 . Two apartments had weekly NO 2 above the California annual outdoor standard of 30 ppb.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Affordable and Accessible Solar for All: Barriers, Solutions, and On-Site Adoption Potential

Solar energy technologies can be used as part of a suite of tools to reduce the energy burden of low-income customers, but to date, low- and moderate-income (LMI) customers have not adopted solar at the same rate as other income groups. This paper summarizes the barriers of LMI solar adoption related to finance and funding, community engagement, site suitability, policy and regulatory, and resilience and recovery and discusses existing and potential future solutions to address these barriers. In addition, we model future LMI on-site solar adoption, using the National Renewable Energy Laboratory's (NREL's) dGen model. We model future scenarios assuming no changes in the current LMI solar policy and program environment, and we add two incentives to low-income households for adopting solar: a $\$$3,000 incentive and a full incentive (i.e., the full cost of a PV system). While we model a financial incentive, this dollar reduction in cost could also come from other efforts, for example, reductions in solar soft costs. We find that by 2050, 48-49% of LMI households adopt solar, resulting in $\$$69- $\$$101 billion in first year utility bill savings to these consumers.

14 SOLAR ENERGY↗

Multi-Unit Dwelling Plug-in EV Charging Innovation Pilots (Final Report)

Nearly one-third of residences in the U.S. are multi-unit dwellings (MUDs), e.g., apartments and condominiums, and MUDs with five or more units account for approximately 45% of rental households. While 80% of EV charging takes place at home, less than 5% of home charging takes place at MUDs. With public electric vehicle (EV) charging still underdeveloped, lack of access to reliable home charging is a major barrier to EV adoption for MUD residents. Challenges to siting electric vehicle supply equipment (EVSE) at MUDs include the high upfront cost of EVSE installation, physical and/or electrical infrastructure constraints, a lack of clear incentives for property managers to invest in installing EV charging for tenants, and a limited number of EV charging service providers that offer solutions adapted to the unique needs of MUDs. Through award DE-EE0008473 from the U.S. Department of Energy’s Office of Energy Efficiency and Renewable Energy (EERE), Center for Sustainable Energy (CSE), Energetics, and Forth, along with a diverse team of partners, led a three-year project to address barriers to EV charging at MUDs by developing an online toolkit geared toward residents, homeowner associations (HOAs), and property managers. The project, referred to as Vehicle Charging Innovations – Multi-Unit Dwellings (VCI-MUD project), engaged stakeholders across the country to identify real and perceived barriers to EV charging at MUDs and explored innovative technologies that attempt to alleviate the identified barriers. Over the course of three and a half years, the project conducted 60 interviews with industry stakeholders, compiled findings in an easy-to-use toolkit, and disseminated the toolkit across national, regional, state, and local channels. Key findings and outcomes of the VCI-MUD project include: Identifying six primary barriers to the installation of EV charging at MUDs; Developing five fact sheets and eight case studies highlighting innovative charging solutions to address barriers, including real-world operational and financial data; Developing a user-friendly, online empowerment toolkit with five important points for “making your pitch” to support EV charging to assist residents, property managers, building managers, and HOAs explore options for MUD charging. The VCI-MUD online toolkit was designed with replicability in mind. It includes general tools and guides to evaluate EV charging demand, gauge readiness for EV charging installation, and develop actionable plans. The fact sheets and case studies highlight the diversity of emerging MUD EV charging solutions, featuring different geographic and structural installation scenarios and providing interested parties with a menu of options, rather than prescribing a one-size-fits-all solution. The following resources are included in the toolkit to provide MUD stakeholders with all the information needed to navigate EV charging installation at their MUD location: Empowerment Toolkit – Easy-to-read FAQ overview, stakeholder roles and responsibilities, and additional resources for MUD EV charging installations; Charging Basics – Glossary of terms and descriptions of charging features, installation and operating expenses; EV Charging Survey Templates – Resident-to-Resident, Property Manager-to-Resident and HOA-to-Resident template letters with pre-populated template questions; Technology Selection Tool – Charging barrier fact sheets and case study examples; Installation Checklist – Submittal document requirements for EVSE installations; MUD Building Self-Evaluation Survey – Self-guided evaluation of potential barriers to EV charging installation at MUD locations; Curbside Resources – Case studies and fact sheets for curbside charging options; Find a Certified Electrician – Approved list of certified EV charging installers; “Right-to-Charge” State Legal References – Legal requirements for charging equipment at MUD locations. The online toolkit was promoted extensively in the final six months of the project and will continue to be disseminated by the Clean Cities Coalitions and other partners after the end of the VCI-MUD project to encourage, support, and demonstrate viable solutions for vehicle charging infrastructure in MUDs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Meaningful Household Savings: Best Practices for Achieving Equitable Solar Development

The Meaningful Household Savings Community of Practice—and this report—focuses on electricity bill savings, other household savings, wealth-building opportunities, and other benefits such as tenant services provided to residents in master-metered buildings. For this report, the project team collected information about ways meaningful household savings have been defined; researched best practices to define, achieve, and quantify meaningful household savings; and identified strategies to scale the adoption and implementation of successful methods.

14 SOLAR ENERGY↗

Screening Tool for Equitable Adoption and Deployment of Solar (STEADy Solar)

The Screening Tool for Equitable Adoption and DeploYment of Solar (STEADy Solar) is a database and mapping tool designed to promoting clean energy investments for low-income communities across the United States. The tool indicates locations that may be eligible for the Investment Tax Credit bonus adders defined in the 2022 Inflation Reduction Act (IRA) and combines this information with demographics, social vulnerability, solar technical potential, solar economics (modeled net present value), and building counts by use-type. It can be used by states, municipalities, community-based organizations, developers, and researchers to identify sites where solar projects may be economical and where federal incentives may be available to support equitable adoption of solar. Specific values include: Areas eligible for the Energy Communities Tax Credit Bonus Program (including brownfield site counts) Areas eligible for the Low Income Communities Bonus Credit Program (including Tribal Lands, and covered affordable housing project counts) Areas categorized as disadvantaged by Justice40 Commercial and Residential Solar economics characterized by the Net Present Value and Simple Payback Period Total Population, Race, and Ethnicity Median Household Income, Poverty rate, Household Tenure Social Vulnerability Count of buildings, developable rooftop solar capacity (in kWdc) and estimated annual generation potential (in kWh) on four building types: Government General Services, Government Emergency Response, Grade Schools, and Colleges/Universities. The linked report describes the STEADy dataset metadata and presents high level insights from the data. The downloadable and formatted excel dataset makes it easy for users to gain insights for their locations. Supporting .csv and shapefiles provide users with the full data to run their own analyses on equitable solar siting.

14 SOLAR ENERGY↗

Development of Integrated Mechanical Pods

This presentation highlights early wins, updated progress, and upcoming developments on ‘national-scale shared development platform’ for rapid prototyping, testing and validation of various integrated Mechanical Pod solutions and form factors. Such pod solutions consist of a set of all-electric heat pump mechanical equipment that have integrated functionalities through built-in controls, with heating, cooling, hot water, ventilation (including energy recovery), electrical management, and battery storage within a single package. The presentation draws inspiration from the success of bathroom pods in the US modular construction industry, UK’s efforts with unitizing mechanical systems as ‘utility cupboards’, and VEIC’s early wins in design-build of all-electric Mechanical Pod solutions in Vermont. The presentation includes researchers and partners involved with NREL in Design for Manufacturing and Assembly (DfMA), Virtual Design and Construction (VDC), and digital twin based process optimization modeling of integrated Mechanical Pod solutions. The presentation aims to highlight early wins from such a platform and how various physical and virtual tools are currently being employed as part of NREL’s ongoing multi-year project funded by US DOE. Streamlined procurement, coordination, installation, and O&M of Mechanical Pods such that the majority of work is delegated to the off-site modular factory implies monetary savings. Such a seemingly basic shift in location of the construction process leads to great reduction in complexity, first cost, lead time, and waste, and greater opportunities for innovative compartmentalization and integration of mechanical systems appropriately sized for each apartment or hotel guest room. However, past studies on unitized combination systems show that high installation costs, maintenance issues, challenges with system integration, limitations in existing electrical infrastructure, and lack of architecturally appealing solutions are key barriers. NREL and partners aim to address key barriers through DfMA approach, rapid prototyping and testing, and digital twin process optimization modeling. The presentation is also a call for interested entities to partner with NREL as part of the national-scale development platform, help drive both product and process innovation, and encourage open source sharing of learnings. Learning objectives include (1) learn about the vision of national-scale shared development platform for process-product innovation on integrated mechanical pod solutions and how to get involved, (2) gain an understanding of the components of an all-electric, high performance home, design characteristics and equipment included in an all-electric mechanical pod, integration of mechanical systems within a modular factories’ assembly line, and the system’s commissioning, operation and maintenance. The pre-planning and coordination with the factory and sub-contractors are also highlighted, (3) gain an understanding of using process modeling tools to quantify resource-constrained performance of operations (such as integration of energy efficiency strategies) to manufacture modules of varying design, (4) gain insights on virtual design, rapid prototyping, and emulated testing of various form factors across different climatic conditions. The need for such preliminary testing with open source sharing of learnings will also be highlighted.

30 DIRECT ENERGY CONVERSION↗

Low Carbon Technology Strategies: Midrise Apartment

This document includes steps that building owners and operators can implement to achieve smart, healthy, and low-carbon midrise apartment buildings within their existing building portfolios. Midrise apartments may use packaged rooftop units for heating, cooling, and ventilation or central plant systems for larger buildings.

analytics↗