Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “module degradation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Performance Modeling of Tandem Photovoltaics: A Yearlong Outdoor Degradation Analysis of a Ga⁢As//Si Minimodule

We present a performance modeling and degradation analysis framework for tandem photovoltaic modules, building upon established procedures for crystalline silicon devices and adapting them to account for the spectral sensitivity of multijunction technologies. The methodology employs filter criteria to select outdoor measurements close to standard test conditions (STC) under stable spectral and ambient conditions, followed by normalization of power production data with corrections for temperature, irradiance, and precipitable water vapor. We demonstrate this framework using a mechanically stacked four-terminal gallium arsenide (Ga⁢As) // silicon (Si) tandem solar minimodule deployed outdoors from October 2019 to January 2021 in Golden, Colorado, USA. We determined degradation rates of −4.1 ±0.2%/year for the Ga⁢As subcell and −2.5 ±0.9%/year for the Si subcell, with analysis of individual performance metrics indicating that packaging degradation, particularly delamination, was the dominant failure mode. Simulations using PVcircuit, an open-source equivalent-circuit solver, confirmed these findings. The presented methodology provides a reproducible foundation for performance modeling and degradation analysis of emerging tandem technologies.

14 SOLAR ENERGY↗

International Space Station Solar Array Wing On-Orbit Electrical Performance Degradation Measured

The port-side photovoltaic power module (P6) was activated on the International Space Station in December 2000. P6 provides electrical power to channels 2B and 4B to operate ISS power loads. A P6 is shown in the preceding photograph. This article highlights the work done at the NASA Glenn Research Center to calculate the on-orbit degradation of the P6 solar array wings (SAWs) using on-orbit data from December 2000 to February 2003. During early ISS operations, the 82 strings of photovoltaic cells that make up a SAW can provide much more power than is necessary to meet the demand. To deal with excess power, a sequential shunt unit successively shunts the current from the strings. This shunt current was the parameter chosen for the SAW performance degradation study for the following reasons: (1) it is based on a direct shunt current measurement in the sequential shunt unit, (2) the shunt current has a low temperature dependence that reduces the data correction error from using a computationally derived array temperature, and (3) the SSU shunt current is essentially the same as the SAW short-circuit current on a per-string basis.

Gustafson, Eric D.↗

Material characterization of seven photovoltaic backsheets using seven accelerated test conditions

A variety of polymeric backsheet materials can be found in fielded photovoltaic (PV) modules, mostly based on fluoropolymer and polyethylene terephthalate (PET) materials. Cost reduction and sustainability considerations drive the recent development of alternative backsheet materials and designs [1]. In some fielded PV installations, polymeric materials are susceptible to environmental degradation in the form of backsheet cracking. To prevent backsheet degradation that can result in a module failure, thorough laboratory reliability testing is needed. In this report we studied the durability of seven commercial and experimental PV backsheets through accelerated stress testing using seven photolytic, hygrometric, and custom tests with the goal to understand if novel fluoropolymer-free backsheets are sufficiently environmentally durable to be commercialized. We divided the mechanisms observed during aging into two categories: core degradation and surface degradation. Although core degradation due to hydrolysis was observed in all commercial PET-, and polyamide (PA)-based backsheets aged with 85 degrees C/85% relative humidity, this test is unlikely to be field relevant. Photo-oxidative reactions on the exposed surface during UV weathering affected all seven backsheets regardless of the outer layer polymer material and additives. This degradation was limited to the outermost micrometers of the surface, except for backsheets containing PA-12, which resulted in surface cracking. A custom test combining UV with water spray caused the most severe backsheet degradation, including surface erosion and loss of insulating properties in polyolefin (PO)- and PA-based backsheets. This highlights the importance of combined accelerated stress testing to screen for complex backsheet degradation mechanisms. We also showed that, with material and design optimization, coextruded experimental PO-based backsheets have the potential to be a durable alternative to commercial PET- and fluoropolymer-based PV backsheets.

14 SOLAR ENERGY↗

Interference susceptibility measurements for an MSK satellite communication link

The results are presented of measurements of the degradation of an MSK satellite link due to modulated and CW (unmodulated) interference. These measurements were made using a hardware based satellite communication link simulator at NASA-Lewis. The results indicate the amount of bit error rate degradation caused by CW interference as a function of frequency and power level, and the degradation caused by adjacent channel and cochannel modulated interference as a function of interference power level. Results were obtained for both the uplink case (including satellite nonlinearity) and the downlink case (linear channel).

Kerczewski, Robert J.↗

Interference susceptibility measurements for an MSK satellite communication link

The results are presented of measurements of the degradation of an MSK satellite link due to modulated and CW (unmodulated) interference. These measurements were made using a hardware based satellite communication link simulator at NASA-Lewis. The results indicate the amount of bit error rate degradation caused by CW interference as a function of frequency and power level, and the degradation caused by adjacent channel and cochannel modulated interference as a function of interference power level. Results were obtained for both the uplink case (including satellite nonlinearity) and the downlink case (linear channel).

Kerczewski, Robert J.↗

Field Study of Nighttime Leakage Currents in Bifacial PV Modules: Correlation with Atmospheric Electric Field Data

Leakage currents measured on PV modules in the field originate from a potential difference between the modules' frame and the cells. They can be a relative indicator of Potential-Induced Degradation (PID) severity, especially when comparing the same module design in a different environment. As modules are not operating at night, no leakage current should be observed but our team has reported several events of nighttime leakage currents on bifacial PV modules. These events have been firstly observed during a thunderstorm that are characterized by strong atmospheric electrical field values. This lead us to believe that nighttime leakage currents could originate from the atmospheric electric charges. In this paper, we correlate nighttime leakage currents measured on bifacial PV modules with field mill data to identify the origin of nighttime leakage currents. Our results show that so far, no leakage currents at night occur when the atmospheric electric field is between 0 and 150–200 V/m (standard value for fair weather). As soon as the atmospheric electric field is out of this range, leakage currents are observed with or without rain involved. This suggests a transport of charged particles from the atmosphere to the modules' frame. A combination of heavy rain with strong atmospheric electric field results into high nighttime leakage currents with a magnitude up to 8 times higher than what observed during the day with -1500V applied. This is explained by an easier transport of the charged particles through the water droplets. Based on these results, leakage currents observed during the day might not be only due to the inherent potential difference between the frame and the cells depending on the atmospheric electric field activity. We believe that it should be taken into account in PID studies.

14 SOLAR ENERGY↗

Development of an Accelerated Test Design for Predicting the Service Life of the Solar Array at Mead, Nebraska

Potential long-term degradation modes for the two types of modules in the Mead array were determined and judgments were made as to those environmental stresses and combinations of stresses which accelerate the degradation of the power output. Hierarchical trees representing the severity of effects of stresses (test conditions) on eleven individual degradation modes were constructed and were pruned of tests judged to be nonessential. Composites of those trees were developed so that there is now one pruned tree covering eight degradation modes, another covering two degradation modes, and a third covering one degradation mode. These three composite trees form the basis for selection of test conditions in the final test plan which is now being prepared.

Gaines, G. B.↗

Impact of Different Thermal Gradients on the Dynamics of Cylindrical Lithium-ion Cells Subject to Accelerated Aging and on Module Performance

This study investigates the impacts of applying different thermal gradient patterns to cylindrical lithium-ion cells in a module on cell dynamics (temperatures, current flows, state of charge), module performance (evolution of resistance, capacity, and energy versus cycle number), and module lifetime. The thermal gradients were generated using cooling plates (CPs) with three different flow-field designs, namely, straight, perpendicular, and U-turn. The study uses computational fluid dynamics (CFD), the pseudo-two-dimensional (P2D) battery model, capacity loss and increased impedance due to the growth of a solid-electrolyte-interphase, and the electric current distribution from module terminals to cells that depends on the series-parallel electrical connections among the cells. The impact of the thermal gradient (resulting from the CP designs) on the variability in resistance, current, state of charge, and voltage among the cells was analyzed and linked to differences in the module's performance. Applying a thermal gradient to parallel-connected strings of series-connected cells led to variation in the current through each parallel string and an imbalance in the voltage of series-connected cells. Module performance is poorer when the thermal gradient causes a voltage imbalance than when it causes a current imbalance. Module performance becomes the worst when both current variation and voltage imbalance happen together. For instance, the module's lifetime (estimated as reaching 80% of its initial capacity) varied by 5% to 17.5%, depending on the magnitude and pattern of the imposed thermal gradient. As the relative orientation between thermal gradients and cells' electrical connectivity influences the module's performance, appropriate consideration should be given to the choice of the CP, especially if large thermal gradients are allowed.

Battery thermal management↗

Predictive Models and Novel Accelerated Tests for the Reliability of Cell Metallization in Photovoltaic Modules (Final Report)

Studies of metallization corrosion m photovoltaics have mainly been limited to comparisons of modules placed in accelerated chambers to fielded modules [1]. Damp Heat accelerated tests and phenomenological equations [2] are used to assess metallization corrosion without understanding the effect of UV light and temperature and humidity cycles on encapsulant adhesion degradation. The roles of encapsulant in-and out-diffusions of moisture and encapsulant impurities are important. Furthermore, few photovoltaic metallization corrosion studies included the role of bias and leakage currents, which are crucial in the electrochemical reaction of metallization. Leakage currents can highly accelerate the corrosion mechanism and are important to include in the studies of corrosion. In our research plan, we will address the following gaps in the PV community's understanding of metallization corrosion: (1) metallization corrosion with bias, humidity, and impurities in the encapsulant or metallization; (2) humidity diffusion through fresh and degraded encapsulants; and (3) comparison of model predictions with outdoor field modules and SunPower's extensive data for its back-contact and front-contact fleets [2] along with NREL's store of >20 year old modules. Our goal is to build models and accelerated tests to predict long term degradation of metallization corrosion of photovoltaic modules in the field. Our studies will include metals used in c-Si solar cells (Cu, Ag, and Al) and commonly used encapsulants (EV A (ethylene vinyl acetate), TPO (thermoplastic olefin), and silicone).

14 SOLAR ENERGY↗

PERFORMANCE CHARACTERIZATION OF THE DIRECT CONTACT MEMBRANE DISTILLATION MODULE OPERATED WITH HIGHLY CONCENTRATED SOLUTION

The experimental study was conducted to characterize the performance of the flat sheet Direct Contact Membrane Distillation. The length degradation was studied in a short and long module with and without spacers. The experimental study is validated using the predicted flux for a wide range of operating conditions using deionized water. Three different membranes are used in the parametric study for feed Reynolds number varied between 500 and 2000, and inlet feed temperature varied between 45°C and 80°C. PTFE membrane was shown to be more effective than the PVDF due to its higher permeability coefficient and higher hydrophobicity. Fouling study was conducted on the selected PTFE membrane with various feed Reynolds numbers between 500 and 2000 and feed inlet temperature between 50°C and 80°C. Membranes used in the fouling study were characterized using scanning electron microscopy (SEM) and X-ray photoelectron spectroscopy (XPS) for the morphology and chemical composition of the fouling layer. 36 hours of operation with 10 wt% NaCl (100,000 ppm) at feed inlet temperatures 80°C and 60°C and fixed Reynolds 2000 demonstrated a drop in flux by 31% and 27%, respectively. Low flow rate and high temperature are favorable conditions for fouling formation and reduced permeate flux for highly concentrated solutions. The spacers improved the flux by 30.8% and 27.6% at the operating Reynolds numbers 2000 the short and long channel modules. This study helps to design and optimize DCMD modules for industrial-size desalination and water treatment applications.

Kim, Deliya↗

Long-Term Degradation of Passivated Emitter and Rear Contact Silicon Solar Cell under Light and Heat

Advanced designs enable high-efficiency solar cells; however, more complex structures create new long-term stability concerns. Herein, the long-term degradation processes affecting advanced silicon solar cells using laboratory-based illumination and heating over hundreds of hours are investigated. The activation energy for the degradation of voltage is estimated and the degradation rates to normal solar cell operating temperature ranges are extrapolated. The cell degradation observed at high temperatures in the lab is kinetically similar to the process affecting field-deployed modules contributing to 0.37% year-1 of annualized degradation. Electroluminescence and photoluminescence mapping show that the degradation is dominated by minority carrier lifetime reduction. Suns-open-circuit voltage and light beam-induced current results indicate that the degradation could result from passivation degradation at the surface or defect formation in the near-subsurface region, leading to increased minority carrier recombination. This work highlights a long-term degradation process under elevated temperature and illumination that may continue to affect cells in an irreversible manner that is separate from recoverable light-induced degradation and light- and elevated temperature-induced degradation.

14 SOLAR ENERGY↗

Nanometer-Scale Measurement of Grid Finger Electrical Conduction Pathways to Detect Series Resistance Degradation of Utility-Scale Silicon Solar Cells

Here, we report on an electrical conduction mechanism for series resistance (Rs) degradation observed in a utility-scale photovoltaic power plant by imaging the local resistance at the Ag/Si interface of the c-Si front metallization. Scanning spreading resistance microscopy imaging with nanometer (nm) scale spatial resolution revealed that the number of point or small-area electrical contacts decreased substantially in a degraded cell compared to an unaffected cell, demonstrating the root cause of Rs degradation. The decrease in electrical contacts is likely caused by a structural change - the Ag particles in contact with the Si cell (or via a nm-thickness tunneling glass layer) aggregate into bulk Ag, and a highly resistive glass frit forms a belt shape at the Ag/Si interface. This resistive belt, with a thickness of ~1 um, blocks the current conduction from the cell emitter to the Ag grid. Our microscopy results help to unravel unambiguously the degradation mechanism and demonstrate an example of the multiscale characterization approach for understanding degradation in field-weathered PV module.

14 SOLAR ENERGY↗

Microstructure changes during failure of PVDF-based photovoltaic backsheets

The backsheet layer of a solar module provides a safety and environmental barrier to the high voltages running through the photovoltaic (PV) cells and electrical contacts within the core of the module. However, in the past decade, backsheet cracking has become one of the most observed failure modes in PV module field surveys. In this work, the degradation of polyvinylidene fluoride (PVDF)-based backsheets is explored. Backsheet samples are either exposed to accelerated laboratory aging (UV light, heat, and moisture) or collected from the field. Fourier transform infrared and Raman spectroscopy, fragmentation testing, atomic force and scanning electron microscopy, and small-angle neutron scattering are combined to develop an understanding of how chemistry and microstructure evolve during aging. Chemical degradation, surface pitting, polymer phase changes, and anisotropic polymer domains are all observed in aged backsheet samples. The results provide insight into the degradation mechanisms that lead to cracking and field failure of PVDF-based backsheets. The comparison of aged PVDF-based backsheets helps to lay the groundwork for limiting polymer-based failure modes in PV modules.

PVDF↗

PVDeg: Development of a Streamlined Tool for PV Degradation Modeling

The photovoltaic (PV) industry constantly aims for lower costs, higher-efficiency cells, and improved module designs. These trends lead to using new materials, designs, and manufacturing processes, resulting in a continually changing technological landscape. These changes can potentially introduce new, unknown degradation mechanisms and failure modes that are difficult to diagnose, analyze, test, and model. This introduces uncertainty into the expected lifetime of PV modules of 25 to 50 years. research efforts aim to achieve this while keeping performance degradation at a minimum for decades. This puts considerable pressure on improving the accuracy of long-term durability and reliability assessments. There is a need to organize the existing degradation data into an accessible format and to provide industry relevant tools for extrapolation from laboratory to field conditions. Because the core of this type of analysis involves calculations that are complicated but ubiquitous for many degradation processes, an enhanced predictive modeling framework will facilitate the analysis to help researchers keep up with the rapid pace of technological changes. In this work, we present an online tool that can be used to search for and analyze degradation information and extrapolate PV module performance and durability to field exposure. The tool will simplify many of the routine computational operations that are common to many degradation studies. The prediction tool will be built modular and published as open source, enabling users to expand on the existing framework. This repository will contain various degradation models and material parameters suitable for the reliability and durability assessment of materials and components deployed outdoors.

degradation↗

Thermal and other tests of photovoltaic modules performed in natural sunlight

The nominal operating cell temperature (NOCT), an effective way to characterize the thermal performance of a photovoltaic module in natural sunlight, is developed. NOCT measurements for more than twenty different modules are presented. Changes in NOCT reflect changes in module design, residential roof mounting, and dirt accumulation. Other test results show that electrical performance is improved by cooling modules with water and by use of a phase change wax. Electrical degradation resulting from the marriage of photovoltaic and solar water heating modules is demonstrated. Cost-effectiveness of each of these techniques is evaluated.

Stultz, J. W.↗

LETID in Legacy and Modern PV Modules: Accelerated Testing and Field Deployment

The kinetics of light- and elevated temperature-induced degradation (LETID) in silicon solar cells depend on the precise operating excess carrier density (?n) of the device. This dependency causes differences in the way LETID manifests in modern, higher-efficiency devices compared to lower-efficiency, legacy devices that might have been deployed in the field in previous years. In this work we model how different vintages of devices are expected to behave in both accelerated laboratory testing, as well as field deployment. The differing excess carrier densities encountered in various module vintages has implications both for interpreting accelerated test data, as well as identifying, diagnosing, and potentially treating LETID in the field.

excess carrier density↗

UV Degradation in Backsheets: A Ray-Tracing Irradiance Simulation Approach

Around 90% of current photovoltaic (PV) modules are less than ten years old. New PV technologies and materials are deployed without documented durability and performance histories. Accelerated testing attempts to capture degradation modes but can produce false results with such rapid deployment of new materials. Current testing assumes UV dosage on the rear of a module to be 10% of that incident on the front. We present a method to quantify degradation on PV backsheets in the field. We aim to evaluate if current acceleration factors for UV damage in chambers are properly estimating degradation for different PV site installations. The method leverages bifacial_radiance to ray-trace and evaluate irradiance on the front and the rear of the modules. Then an equation to estimate the relative degradation is proposed.

accelerated testing↗