Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “minimum”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

TH-C-18A-11: Investigating the Minimum Scan Parameters Required to Generate Free-Breathing Fast-Helical CT Scans Without Motion-Artifacts

Purpose: A recently proposed 4D-CT protocol uses deformable registration of free-breathing fast-helical CT scans to generate a breathing motion model. In order to allow accurate registration, free-breathing images are required to be free of doubling-artifacts, which arise when tissue motion is greater than scan speed. This work identifies the minimum scanner parameters required to successfully generate free-breathing fast-helical scans without doubling-artifacts. Methods: 10 patients were imaged under free breathing conditions 25 times in alternating directions with a 64-slice CT scanner using a low dose fast helical protocol. A high temporal resolution (0.1s) 4D-CT was generated using a patient specific motion model and patient breathing waveforms, and used as the input for a scanner simulation. Forward projections were calculated using helical cone-beam geometry (800 projections per rotation) and a GPU accelerated reconstruction algorithm was implemented. Various CT scanner detector widths and rotation times were simulated, and verified using a motion phantom. Doubling-artifacts were quantified in patient images using structural similarity maps to determine the similarity between axial slices. Results: Increasing amounts of doubling-artifacts were observed with increasing rotation times > 0.2s for 16×1mm slice scan geometry. No significant increase in doubling artifacts was observed for 64×1mm slice scan geometry up to 1.0s rotation time although blurring artifacts were observed >0.6s. Using a 16×1mm slice scan geometry, a rotation time of less than 0.3s (53mm/s scan speed) would be required to produce images of similar quality to a 64×1mm slice scan geometry. Conclusion: The current generation of 16 slice CT scanners, which are present in most Radiation Oncology departments, are not capable of generating free-breathing sorting-artifact-free images in the majority of patients. The next generation of CT scanners should be capable of at least 53mm/s scan speed in order to use a fast-helical 4D-CT protocol to generate a motion-artifact free 4D-CT. NIH R01CA096679.

60 APPLIED LIFE SCIENCES↗

SU-E-T-364: Estimating the Minimum Number of Patients Required to Estimate the Required Planning Target Volume Margins for Prostate Glands

Purpose: To establish a minimum number of patients required to obtain statistically accurate Planning Target Volume (PTV) margins for prostate Intensity Modulated Radiation Therapy (IMRT). Methods: A total of 320 prostate patients, consisting of a total number of 9311 daily setups, were analyzed. These patients had gone under IMRT treatments. Daily localization was done using the skin marks and the proper shifts were determined by the CBCT to match the prostate gland. The Van Herk formalism is used to obtain the margins using the systematic and random setup variations. The total patient population was divided into different grouping sizes varying from 1 group of 320 patients to 64 groups of 5 patients. Each grouping was used to determine the average PTV margin and its associated standard deviation. Results: Analyzing all 320 patients lead to an average Superior-Inferior margin of 1.15 cm. The grouping with 10 patients per group (32 groups) resulted to an average PTV margin between 0.6–1.7 cm with the mean value of 1.09 cm and a standard deviation (STD) of 0.30 cm. As the number of patients in groups increases the mean value of average margin between groups tends to converge to the true average PTV of 1.15 cm and STD decreases. For groups of 20, 64, and 160 patients a Superior-Inferior margin of 1.12, 1.14, and 1.16 cm with STD of 0.22, 0.11, and 0.01 cm were found, respectively. Similar tendency was observed for Left-Right and Anterior-Posterior margins. Conclusion: The estimation of the required margin for PTV strongly depends on the number of patients studied. According to this study at least ∼60 patients are needed to calculate a statistically acceptable PTV margin for a criterion of STD < 0.1 cm. Numbers greater than ∼60 patients do little to increase the accuracy of the PTV margin estimation.

60 APPLIED LIFE SCIENCES↗

SU-F-J-206: Systematic Evaluation of the Minimum Detectable Shift Using a Range- Finding Camera

Purpose: The robotic table used for patient alignment in proton therapy is calibrated only at commissioning under well-defined conditions and table shifts may vary over time and with differing conditions. The purpose of this study is to systematically investigate minimum detectable shifts using a time-of-flight (TOF) range-finding camera for table position feedback. Methods: A TOF camera was used to acquire one hundred 424 × 512 range images from a flat surface before and after known shifts. Range was assigned by averaging central regions of the image across multiple images. Depth resolution was determined by evaluating the difference between the actual shift of the surface and the measured shift. Depth resolution was evaluated for number of images averaged, area of sensor over which depth was averaged, distance from camera to surface, central versus peripheral image regions, and angle of surface relative to camera. Results: For one to one thousand images with a shift of one millimeter the range in error was 0.852 ± 0.27 mm to 0.004 ± 0.01 mm (95% C.I.). For varying regions of the camera sensor the range in error was 0.02 ± 0.05 mm to 0.47 ± 0.04 mm. The following results are for 10 image averages. For areas ranging from one pixel to 9 × 9 pixels the range in error was 0.15 ± 0.09 to 0.29 ± 0.15 mm (1σ). For distances ranging from two to four meters the range in error was 0.15 ± 0.09 to 0.28 ± 0.15 mm. For an angle of incidence between thirty degrees and ninety degrees the average range in error was 0.11 ± 0.08 to 0.17 ± 0.09 mm. Conclusion: It is feasible to use a TOF camera for measuring shifts in flat surfaces under clinically relevant conditions with submillimeter precision.

60 APPLIED LIFE SCIENCES↗

On the neutronization radius of magnetic neutron stars: The field and temperature dependences of the chemical potential and minimum number density of a degenerate magnetized electron gas

The temperature and field dependences of the chemical potential and the field dependence of the Fermi energy for a degenerate relativistic electron gas in a magnetic field have been analyzed by numerical and analytical methods. An analytical expression has been derived for the dependence of the minimum electron number density and the corresponding neutronization radius on the magnetic field strength in a collapsing star upon its subsequent transformation into a neutron one. We believe that a similar relation also holds for the equilibrium neutron star radius. Our results refine the conclusions reached previously [1] in the case of a nonzero temperature and the influence of the star's proton component on the neutronization process as well as confirm and generalize them in terms of a significant (by an order of magnitude or severalfold) decrease in the equilibrium radius of a neutron star in a superstrong (10{sup 14}-10{sup 17} G) magnetic field compared to the case where there is no such field. We point out that there may exist a separate class of stellar objects-very small magnetar neutron stars that we propose to name 'minimagnetars'. We hypothesize that they can be the final evolutionary stage of stars before their collapse into a black hole.

79 ASTRONOMY AND ASTROPHYSICS↗

Transverse sphericity of primary charged particles in minimum bias proton–proton collisions at $\sqrt{s}$ = 0.9, 2.76 and 7 TeV

Measurements of the sphericity of primary charged particles in minimum bias proton–proton collisions at $\sqrt{s}$ = 0.9, 2.76 and 7 TeV with the ALICE detector at the LHC are presented. The observable is measured in the plane perpendicular to the beam direction using primary charged tracks with $p_T$ > 0.5 GeV/c in |η| < 0.8. The mean sphericity as a function of the charged particle multiplicity at mid-rapidity ($N_ch$) is reported for events with different $p_T$ scales (“soft” and “hard”) defined by the transverse momentum of the leading particle. In addition, the mean charged particle transverse momentum versus multiplicity is presented for the different event classes, and the sphericity distributions in bins of multiplicity are presented. The data are compared with calculations of standard Monte Carlo event generators. The transverse sphericity is found to grow with multiplicity at all collision energies, with a steeper rise at low N ch, whereas the event generators show an opposite tendency. The combined study of the sphericity and the mean p T with multiplicity indicates that most of the tested event generators produce events with higher multiplicity by generating more back-to-back jets resulting in decreased sphericity (and isotropy). The PYTHIA6 generator with tune PERUGIA-2011 exhibits a noticeable improvement in describing the data, compared to the other tested generators.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Neuromorphic Graph Algorithms: Extracting Longest Shortest Paths and Minimum Spanning Trees

Neuromorphic computing is poised to become a promising computing paradigm in the post Moore's law era due to its extremely low power usage and inherent parallelism. Traditionally speaking, a majority of the use cases for neuromorphic systems have been in the field of machine learning. In order to expand their usability, it is imperative that neuromorphic systems be used for non-machine learning tasks as well. The structural aspects of neuromorphic systems (i.e., neurons and synapses) are similar to those of graphs (i.e., nodes and edges), However, it is not obvious how graph algorithms would translate to their neuromorphic counterparts. In this work, we propose a preprocessing technique that introduces fractional offsets on the synaptic delays of neuromorphic graphs in order to break ties. This technique, in turn, enables two graph algorithms: longest shortest path extraction and minimum spanning trees.

Kay, Bill↗

A single-tree algorithm to compute the Euclidean minimum spanning tree on GPUs

Computing the Euclidean minimum spanning tree (Emst) is a computationally demanding step of many algorithms. While work-efficient serial and multithreaded algorithms for computing Emst are known, designing an efficient GPU algorithm is challenging due to a complex branching structure, data dependencies, and load imbalances. In this paper, we propose a single-tree $Bor\mathring{u}vka$-based algorithm for computing Emst on GPUs. We use an efficient nearest neighbor algorithm and reduce the number of the required distance calculations by avoiding traversing subtrees with leaf nodes in the same component. The developed algorithms are implemented in a performance portable way using ArborX, an open-source geometric search library based on the Kokkos framework. We evaluate the proposed algorithm on various 2D and 3D datasets, show and compare it with the current state-of-the-art open-source CPU implementations. We demonstrate 4-24 × speedup over the fastest multi-threaded implementation. We prove the portability of our implementation by providing results on a variety of hardware: AMD EPYC 7763, Nvidia A100 and AMD MI250X. We show scalability of the implementation, computing Emst for 37 million 3D cosmological dataset in under a 0.5 second on a single A100 Nvidia GPU.

Prokopenko, Andrey↗

Searching for Minimum in Dependence of Squared Speed-of-Sound on Collision Energy

Experimental results of the rapidity distributions of negatively charged pions produced in proton-proton ( p - p ) and beryllium-beryllium (Be-Be) collisions at different beam momentums, measured by the NA61/SHINE Collaboration at the super proton synchrotron (SPS), are described by a revised (three-source) Landau hydrodynamic model. The squared speed-of-sound parameter c s 2 is then extracted from the width of rapidity distribution. There is a local minimum (knee point) which indicates a softest point in the equation of state (EoS) appearing at about 40 A GeV/ c (or 8.8 GeV) in c s 2 excitation function (the dependence of c s 2 on incident beam momentum (or center-of-mass energy)). This knee point should be related to the searching for the onset of quark deconfinement and the critical point of quark-gluon plasma (QGP) phase transition.

74 ATOMIC AND MOLECULAR PHYSICS↗

The Effect of Fault Geometry and Minimum Shear Wavespeed on 3D Ground-Motion Simulations for an M w 6.5 Hayward Fault Scenario Earthquake, San Francisco Bay Area, Northern California

We investigated the effects of fault geometry and assumed minimum shear wavespeed (V Smin ) on 3D ground-motion simulations (0–2.5 Hz) in general, using a moment magnitude (M w ) 6.5 earthquake on the Hayward fault (HF). Simulations of large earthquakes on the northeast-dipping HF using the U.S. Geological Survey (USGS) 3D seismic model have shown intensity asymmetry with stronger shaking for the Great Valley Sequence east of the HF (hanging wall) relative to the Franciscan Complex to the west (footwall). We performed simulations with three fault geometries in both plane-layered (1D) and 3D models. Results show that the nonvertical fault geometries result in larger motions on the hanging wall relative to the vertical fault for the same Earth model with up to 50% amplifications in single-component peak ground velocity (PGV) within 10 km of the rupture. Near-fault motions on the footwall are reduced for the nonvertical faults, but less than they are increased on the hanging wall. Simulations assuming V Smin values of 500 and 250 m/s reveal that PGVs are on average 25% higher west of the HF when using the lower V Smin ,with some locations amplified by a factor of 3. Increasing frequency content from 2.5 to 5 Hz increases PGV values. Spectral ratios of these two V Smin cases show average amplifications of 2–4 (0.5–1.5 Hz) for the lower V Smin west of the fault. Large differences (up to 2×) in PGV across the HF from previous studies persist even for the case with a vertical fault or V Smin of 250 m/s. We conclude that assuming a V Smin of 500 m/s underestimates intensities west of the HF for frequencies above 0.5 Hz, and that low upper crustal (depth <10 km) shear wavespeeds defined in the 3D model contribute most to higher intensities east of the HF.

58 GEOSCIENCES↗

Analysis on Achieving a Minimum Bunch Length in LCLS Bunch Compressor One

An ultra-short bunch is required by different applications in many aspects. In this paper, the condition to achieve a minimum bunch length at the Linac Coherent Light Source (LCLS) [1] bunch compressor one (BC1) is analyzed analytically and evaluated by simulation. The space charge, wake field and coherent synchrotron radiation (CSR) effects are not discussed here.

43 PARTICLE ACCELERATORS↗

Determine Minimum Silver Flake Addition to GCM for Iodine Loaded AgZ

The minimum amount of silver flake required to prevent loss of I{sub 2} during sintering in air for a SNL Glass Composite Material (GCM) Waste Form containing AgI-MOR (ORNL, 8.7 wt%) was determined to be 1.1 wt% Ag. The final GCM composition prior to sintering was 20 wt% AgI-MOR, 1.1 wt% Ag, and 80 wt% Bi-Si oxide glass. The amount of silver flake needed to suppress iodine loss was determined using thermo gravimetric analysis with mass spectroscopic off-gas analysis. These studies found that the ratio of silver to AgI-MOR required is lower in the presence of the glass than without it. Therefore an additional benefit of the GCM is that it serves to inhibit some iodine loss during processing. Alternatively, heating the AgI-MOR in inert atmosphere instead of air allowed for densified GCM formation without I{sub 2} loss, and no necessity for the addition of Ag. The cause of this behavior is found to be related to the oxidation of the metallic Ag to Ag{sup +} when heated to above ~300{degrees}C in air. Heating rate, iodine loading levels and atmosphere are the important variables that determine AgI migration and results suggest that AgI may be completely incorporated into the mordenite structure by the 550{degrees}C sintering temperature.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Estimate of Cost-Effective Potential for Minimum Efficiency Performance Standards in 13 Major World Economies: Energy Savings, Environmental and Financial Impacts

This study analyzes the financial impacts on consumers of minimum efficiency performance standards (MEPS) for appliances that could be implemented in 13 major economies around the world. We use the Bottom-Up Energy Analysis System (BUENAS), developed at Lawrence Berkeley National Laboratory (LBNL), to analyze various appliance efficiency target levels to estimate the net present value (NPV) of policies designed to provide maximum energy savings while not penalizing consumers financially. These policies constitute what we call the “cost-effective potential” (CEP) scenario. The CEP scenario is designed to answer the question: How high can we raise the efficiency bar in mandatory programs while still saving consumers money?

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Estimate of Technical Potential for Minimum Efficiency Performance Standards in 13 Major World Economies

As part of the ongoing effort to estimate the foreseeable impacts of aggressive minimum efficiency performance standards (MEPS) programs in the world’s major economies, Lawrence Berkeley National Laboratory (LBNL) has developed a scenario to analyze the technical potential of MEPS in 13 major economies around the world1 . The “best available technology” (BAT) scenario seeks to determine the maximum potential savings that would result from diffusion of the most efficient available technologies in these major economies.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Impact of Rate Design Alternatives on Residential Solar Customer Bills. Increased Fixed Charges, Minimum Bills and Demand-based Rates

With rapid growth in energy efficiency and distributed generation, electric utilities are anticipating stagnant or decreasing electricity sales, particularly in the residential sector. Utilities are increasingly considering alternative rates structures that are designed to recover fixed costs from residential solar photovoltaic (PV) customers with low net electricity consumption. Proposed structures have included fixed charge increases, minimum bills, and increasingly, demand rates - for net metered customers and all customers. This study examines the electricity bill implications of various residential rate alternatives for multiple locations within the United States. For the locations analyzed, the results suggest that residential PV customers offset, on average, between 60% and 99% of their annual load. However, roughly 65% of a typical customer's electricity demand is non-coincidental with PV generation, so the typical PV customer is generally highly reliant on the grid for pooling services.

14 SOLAR ENERGY↗

Confronting Regulatory Cost and Quality Expectations. An Exploration of Technical Change in Minimum Efficiency Performance Standards

The dual purpose of this project was to contribute to basic knowledge about the interaction between regulation and innovation and to inform the cost and benefit expectations related to technical change which are embedded in the rulemaking process of an important area of national regulation. The area of regulation focused on here is minimum efficiency performance standards (MEPS) for appliances and other energy-using products. Relevant both to U.S. climate policy and energy policy for buildings, MEPS remove certain product models from the market that do not meet specified efficiency thresholds.

99 GENERAL AND MISCELLANEOUS↗

Investigation of Archived Gamma Data to Report Minimum Detectable Activities for Gamma-Emitting Radionuclides in Groundwater Samples

Los Alamos National Laboratory (LANL) has performed gamma analyses on ground water samples from the Nevada National Security Site (NNSS) (previously known as the Nevada Test Site or NTS) for the last 50 years. During that time, LANL has reported all of the detected radionuclides in various reports, letters and publications. However, until recently, no minimum detectable activities (MDAs) for undetected radionuclides of interest have been reported. In fact, most gamma emitting radionuclides were not detected in groundwater samples above their respective MDAs, and the MDAs can be used to define upper -bound activities for these radionuclides in the groundwater samples.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Minimum Detectable Concentration and Concentration Calculations

This report highlights the work that has been completed on concentration calculations, uncertainties and minimum detectable concentration (MDC) for radioxenon collection systems. A discussion on the theory behind MDC calculations is given. In addition, regions of interest (ROI) and their role in correcting for both memory effects and interference terms are given in detail. A detailed derivation and walkthrough of the calculation is given with some discussion at each stage of the equation. Finally, some specific examples are given with typical numbers from an ARSA system as a guide.

61 RADIATION PROTECTION AND DOSIMETRY↗

Testing Minimum Detectable Activity of Whole-Body Counting System in the Presence of Interfering Factors

The recently updated technical standard for the Department of Energy Laboratory Accreditation Program (DOELAP) may soon require accredited laboratories to empirically verify the estimated minimum detectable activity (MDA) for the nuclides of interest measured by in-vivo detection systems. The Radiation Protection Sample Diagnostics (RPSD) program is the SNL on-site DOELAP accredited laboratory that provides in-vivo measurements of ingested gamma-emitting nuclides (or to prove the lack of significant ingested gamma-emitting nuclides) for the internal dosimetry program administered by Radiation Protection Dosimetry Program (RPDP). Currently, the main nuclides of concern for RPDP include cesium-137 and cobalt-60 as specified in the Statement of Work between the two programs. Historically, MDAs for the RPSD whole-body counting system (WBC) were calculated annually as a-priori values by averaging the critical levels (LC) of any twelve subjects with undetected Co-60 and Cs-137 and assuming MDA is twice the decision level. The purpose of this technical basis document is to evaluate the method and process that validates the a-priori MDA of the RPSD WBC.

61 RADIATION PROTECTION AND DOSIMETRY↗