Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “membrane separation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Rotating Reverse-Osmosis for Water Purification

A new design for a water-filtering device combines rotating filtration with reverse osmosis to create a rotating reverse- osmosis system. Rotating filtration has been used for separating plasma from whole blood, while reverse osmosis has been used in purification of water and in some chemical processes. Reverse- osmosis membranes are vulnerable to concentration polarization a type of fouling in which the chemicals meant not to pass through the reverse-osmosis membranes accumulate very near the surfaces of the membranes. The combination of rotating filtration and reverse osmosis is intended to prevent concentration polarization and thereby increase the desired flux of filtered water while decreasing the likelihood of passage of undesired chemical species through the filter. Devices based on this concept could be useful in a variety of commercial applications, including purification and desalination of drinking water, purification of pharmaceutical process water, treatment of household and industrial wastewater, and treatment of industrial process water. A rotating filter consists of a cylindrical porous microfilter rotating within a stationary concentric cylindrical outer shell (see figure). The aqueous suspension enters one end of the annulus between the inner and outer cylinders. Filtrate passes through the rotating cylindrical microfilter and is removed via a hollow shaft. The concentrated suspension is removed at the end of the annulus opposite the end where the suspension entered.

Lueptow, RIchard M.↗

Biologically Pre-Treated Habitation Waste Water as a Sustainable Green Urine Pre-Treat Solution

The ability to recover water from urine and flush water is a critical process to allow long term sustainable human habitation in space or bases on the moon or mars. Organic N present as urea or similar compounds can hydrolyze producing free ammonia. This reaction results in an increase in the pH converting ammonium to ammonia which is volatile and not removed by distillation. The increase in pH will also cause precipitation reactions to occur. In order to prevent this, urine on ISS is combined with a pretreat solution. While use of a pretreatment solution has been successful, there are numerous draw backs including: storage and use of highly hazardous solutions, limitations on water recovery (less than 85%), and production of brine with pore dewatering characteristics. We evaluated the use of biologically treated habitation wastewaters (ISS and early planetary base) to replace the current pretreat solution. We evaluated both amended and un-amended bioreactor effluent. For the amended effluent, we evaluated "green" pretreat chemicals including citric acid and citric acid amended with benzoic acid. We used a mock urine/air separator modeled after the urine collection assembly on ISS. The urine/air separator was challenged continually for >6 months. Depending on the test point, the separator was challenged daily with donated urine and flushed with amended or un-amended reactor effluent. We monitored the pH of the urine, flush solution and residual pH in the urine/air separator after each urine event. We also evaluated solids production and biological growth. Our results support the use of both un-amended and amended bioreactor effluent to maintain the operability of the urine /air separator. The ability to use bioreactor effluent could decrease consumable cost, reduce hazards associated with current pre-treat chemicals, allow other membrane based desalination processes to be utilized, and improve brine characteristics.

Jackson, W. Andrew↗

Develop Recovery Systems for Separations of Salts from Process Streams for use in Advanced Life Support System

The main objectives of this project were the development of a four-compartment electrolytic cell using high selective membranes to remove nitrate from crop residue leachate and convert it to nitric acid, and the development of an six compartment electrodialysis cell to remove selectively sodium from urine wastes. The recovery of both plant inedible biomass and human wastes nutrients to sustain a biomass production system are important aspects in the development of a controlled ecological life support system (CELSS) to provide the basic human needs required for life support during long term space missions. A four-compartment electrolytic cell has been proposed to remove selectively nitrate from crop residue and to convert it to nitric acid, which is actually used in the NASA-KSC Controlled Ecological Life Support System to control the pH of the aerobic bioreactors and biomass production chamber. Human activities in a closed system require large amount of air, water and minerals to sustain life and also generate wastes. Before using human wastes as nutrients, these must be treated to reduce organic content and to remove some minerals which have adverse effects on plant growth. Of all the minerals present in human urine, sodium chloride (NACl) is the only one that can not be used as nutrient for most plants. Human activities also requires sodium chloride as part of the diet. Therefore, technology to remove and recover sodium chloride from wastes is highly desirable. A six-compartment electrodialysis cell using high selective membranes has been proposed to remove and recover NaCl from human urine.

Colon, Guillermo↗

Correlated Changes in Retinal Thickness and Visuomotor Function in Asymptomatic Plaquenil Toxicity Patients

We have previously shown that a 5-minute eye-movement test can capture a number of largely independent “oculometric” parameters of human visual/visuomotor function (Liston & Stone, 2014). This test has been successfully used to characterize mild neural impairment due to traumatic brain injury, sleep and circadian disruption, and alcohol consumption (Liston et al., 2017; Stone et al, 2019; Tyson et al, 2021). Here, we extend this approach to study patients at risk of progressive posterior-segment illness to see how oculometrics relate to standard clinical ophthalmological measures. Five female patients (<20:40 BCVA, 34-60 years old) undergoing hydroxychloroquine treatment (2-7mg/kg/day for 10-23 years for rheumatologic illness) have participated thus far. Under monocular viewing conditions in randomized order, they tracked a moving spot undergoing radial step-ramp motion in one of 90 randomized directions, at one of 5 randomized speeds, starting at random times (for details, see Stone et al, 2019). We computed nine independent oculometrics (latency, initial acceleration, steady-state gain, proportion smooth, saccadic rate, saccadic amplitude, direction noise, speed responsiveness, and speed noise). Spectral-domain optical coherence tomography (Zeiss, Dublin, CA) was used to measure the average thickness of the nine Early Treatment Diabetic Retinopathy Study macular sectors from the internal limiting membrane to the retinal pigmented epithelium. We used Pearson’s correlation between retinal thickness and our oculometrics with t-statistics to test separate one-sided hypotheses across 10 retinae. Our preliminary analysis found significant changes in several different aspects of visuomotor performance. Most notably, latency increased, initial acceleration decreased, and steady-state pursuit gain decreased as retinal thickness decreased (r2 = 0.364, 0.579, and 0.692; one-tailed P = 0.032, 0.005, and 0.001, respectively). Speed responsiveness appeared to decrease, but this effect was marginal for our current sample (r2 = 0.253, P = 0.069). Lastly, direction discrimination and saccadic behavior appeared unchanged. We conclude that oculometrics may provide sensitive measures of changes in retinal thickness. More importantly, oculometrics have the potential to detect impairment before it becomes evident with standard clinical imaging tools, while also providing insight into the behavioral implications of any resulting deficits in visual/visuomotor function.

eye movements↗

Distribution and Spectroscopy of Green Fluorescent Protein and Acyl-CoA: Cholesterol Acytransferase in Sf21 Insect Cells

Acyl-CoA: cholesterol acyltransferase (ACAT) is thought to significantly participate in the pathway of cholesterol esterification that underlies the pathology of artherosclerosis. This enzyme is a membrane protein known to be preferentially bound within the endoplasmic reticulum of mammalian cells, from which location it esterifies cholesterol derived from low density lipoprotein. Cultures of insect cells were separately infected with baculovirus containing the gene for green fluroescent protein (GFP) and with baculovirus containing tandem genes for GFP and ACAT. These infected cultures expressed GFP and the fusion protein GCAT, respectively, with maximum expression occurring on the fourth day after infection. Extraction of GFP- and of GCAT-expressing cells with urea and detergent resulted in recovery of fluorescent protein in aqueous solution. Fluorescence spectra at neutral pH were identical for both GFP and GCAT extracts in aqueous solution, indicating unperturbed tertiary structure for the GFP moiety within GCAT. In a cholesterol esterification assay, GCAT demonstrated ACAT activity, but with less efficiency compared to native ACAT. It was hypothesized that the membrane protein ACAT would lead to differences in localization of GCAT compared to GFP within the respective expressing insect cells. The GFP marker directly and also within the fusion protein GCAT was accordingly used as the intracellular probe that was fluorescently analyzed by the new biophotonics technique of hyperspectral imaging. In that technique, fluorescence imaging was obtained from two dimensional arrays of cells, and regions of interest from within those images were then retrospectively analyzed for the emission spectra that comprises the image. Results of hyperspectral imaging of insect cells on day 4 postinfection showed that GCAT was preferentially localized to the cytoplasm of these cells compared to GFP. Furthermore, the emission spectra obtained for the localized GCAT displayed a peak blue shift from 518nm obtained in neutral aqueous solution to 505nm obtained in localized regions within the cells. This blue shift indicates change in the fluorescence coupling of the GFP moiety of GCAT. It is hypothesized that change in tertiary environment of GCAT, coincident with intracellular deposition of GCAT, follows from intracellular trafficking of GCAT leading to membrane interactions with the ACAT moiety, and/or self-assembly of GCAT, that alters the chromophore environment of the GFP moiety of GCAT. These findings introduce a new technique of biophotonic imaging to studies of intracellular protein trafficking and interactions. This technique of hyperspectral imaging could contribute to advancing the emergent field of proteomics. Because of the noninvasive nature of this technique, kinetic processes associated with intracellular protein trafficking, and interactions of proteins within cellular domains, can be considered for investigation within a single cell as well as a cell population.

Richmond, R. C.↗

Impact experiments into multiple-mesh targets: Concept development of a lightweight collisional bumper

The utility of multiple-mesh targets as potential lightweight shields to protect spacecraft in low-Earth orbit against collisional damage is explored. Earlier studies revealed that single meshes comminute hypervelocity impactors with efficiencies comparable to contiguous targets. Multiple interaction of projectile fragments with any number of meshes should lead to increased comminution, deceleration, and dispersion of the projectile, such that all debris exiting the mesh stack possesses low specific energies (ergs/sq cm) that would readily be tolerated by many flight systems. The study is conceptually exploring the sensitivity of major variables such as impact velocity, the specific areal mass (g/sq cm) of the total mesh stack (SM), and the separation distance (S) between individual meshes. Most experiments employed five or ten meshes with total SM typically less than 0.5 the specific mass of the impactor, and silicate glass impactors rather than metal projectiles. While projectile comminution increases with increasing impact velocity due to progressively higher shock stresses, encounters with multiple-meshes at low velocity (1-2 km/s) already lead to significant disruption of the glass impactors, with the resulting fragments being additionally decelerated and dispersed by subsequent meshes, and, unlike most contiguous single-plate bumpers, leading to respectable performance at low velocity. Total specific bumper mass must be the subject of careful trade-off studies; relatively massive bumpers will generate too much debris being dislodged from the bumper itself, while exceptionally lightweight designs will not cause sufficient comminution, deceleration, or dispersion of the impactor. Separation distance was found to be a crucial design parameter, as it controls the dispersion of the fragment cloud. Substantial mass savings could result if maximum separation distances were employed. The total mass of debris dislodged by multiple-mesh stacks is modestly smaller than that of single, contiguous-membrane shields. The cumulative surface area of all penetration holes in multiple mesh stacks is an order of magnitude smaller than that in analog multiple-foil shields, suggesting good long-term performance of the mesh designs. Due to different experimental conditions, direct and quantitative comparison with other lightweight shields is not possible at present.

Hoerz, Friedrich↗

Solubilization and Resolution of the Membrane-Bound Nitrite Reductase from Paracoccus Halodenitrificans into Nitrite and Nitric Oxide Reductases

Membranes prepared from Paracoccus halodenitrificans reduced nitrite or nitric oxide to nitrous oxide. Extraction of these membranes with the detergent CHAPSO [3-(3-Chlolamidoporopyldimethylammonio)-1-(2- hydroxy-1-propanesulfonate)], followed by ammonium sulfate fractionation of the solubilized proteins, resulted in the separation of nitrite and nitric oxide reductase activities. The fraction containing nitrite reductase activity spectrally resembled a cd-type cytochrome. Several cytochromes were detected in the nitric oxide reductase fraction. Which, if any, of these cytochromes is associated with the reduction of nitric oxide is not clear at this time.

Grant, Michael A.↗

Energy Storage Project

NASA's Exploration Technology Development Program funded the Energy Storage Project to develop battery and fuel cell technology to meet the expected energy storage needs of the Constellation Program for human exploration. Technology needs were determined by architecture studies and risk assessments conducted by the Constellation Program, focused on a mission for a long-duration lunar outpost. Critical energy storage needs were identified as batteries for EVA suits, surface mobility systems, and a lander ascent stage; fuel cells for the lander and mobility systems; and a regenerative fuel cell for surface power. To address these needs, the Energy Storage Project developed advanced lithium-ion battery technology, targeting cell-level safety and very high specific energy and energy density. Key accomplishments include the development of silicon composite anodes, lithiated-mixed-metal-oxide cathodes, low-flammability electrolytes, and cell-incorporated safety devices that promise to substantially improve battery performance while providing a high level of safety. The project also developed "non-flow-through" proton-exchange-membrane fuel cell stacks. The primary advantage of this technology set is the reduction of ancillary parts in the balance-of-plant--fewer pumps, separators and related components should result in fewer failure modes and hence a higher probability of achieving very reliable operation, and reduced parasitic power losses enable smaller reactant tanks and therefore systems with lower mass and volume. Key accomplishments include the fabrication and testing of several robust, small-scale nonflow-through fuel cell stacks that have demonstrated proof-of-concept. This report summarizes the project s goals, objectives, technical accomplishments, and risk assessments. A bibliography spanning the life of the project is also included.

Mercer, Carolyn R.↗

Technology Assessment for Producing Propellant From Lunar Water

Introduction: The presence of water ice in permanently shadowed regions (PSRs) on the lunar surface may enable a sustained human presence on the Moon with minimal need for consumables. One of the most valuable uses of lunar water is to produce rocket propellant. A sustained human presence on the Moon will re-quire frequent launches from the lunar surface, and each launch will require tons of propellant. However, many other volatiles are likely to be present in the areas where lunar water is stable1. Producing propellant from lunar water in-situ will require the separation and purification of water before it can be electrolyzed into oxygen and hydrogen gas. The Resource Exploration and Science of OUR Cosmic Environment (RESOURCE) project, funded by the Solar System Exploration Research Virtual Institute (SSERVI) program, includes a task to demonstrate the end-to-end process of water extraction, capture, purification and electrolysis to produce pure/dry oxygen gas sourced from an icy regolith mixture. Water Purification: The requirements for water purity are driven by the type of water electrolyzer used. For example, the water electrolyzer currently used on the International Space Station is based on proton ex-change membrane (PEM) technology. PEM-based electrolyzers require water to be ultrapure and deionized (>10 MegaOhm-cm) so that electrical conductivity is limited to the membranes themselves, where electrical current is used to convert H2O into H2 and O2.. A practical first step toward purifying water that is sourced from a lunar PSR is to use freeze distillation to separate water from other volatiles2. A sub-micronic filter can also be used to ensure that a minimal amount of dust is present in any lunar water that is captured. The combination of freeze distillation and sub-micronic filtration will result in relatively pure water but would require a deionization step if being fed into a PEM electrolyzer. Water Electrolysis: An alternative to PEM electrolysis is to use a Solid Oxide Electrolyzer (SOE). This technology operates at a much higher operating temperature (~800oC) and has a limited pressure range but does not require water to be ultrapure and deionized. Another advantage of SOE technology is that it produces pure dry oxygen gas without the need of an additional drying step. PEM electrolyzers produce humid oxygen gas and the humidity must be removed prior to liquefaction. Assessment: In order to compare PEM and SOE technologies side-by-side, they must be compared at a system level that includes water purification and gas drying steps. Engineers at the Johnson Space Center up-dated and utilized a detailed In-Situ Resource Utilization (ISRU) system model to compare and select the best option for the RESOURCE project which will conclude with a laboratory demonstration of the process of producing pure/dry oxygen from an icy regolith mixture in 2025.

A.J. Paz↗

Technology Assessment for Producing Propellant From Lunar Water

Introduction: The presence of water ice in permanently shadowed regions (PSRs) on the lunar surface may enable a sustained human presence on the Moon with minimal need for consumables. One of the most valuable uses of lunar water is to produce rocket propellant. A sustained human presence on the Moon will re-quire frequent launches from the lunar surface, and each launch will require tons of propellant. However, many other volatiles are likely to be present in the areas where lunar water is stable1. Producing propellant from lunar water in-situ will require the separation and purification of water before it can be electrolyzed into oxygen and hydrogen gas. The Resource Exploration and Science of OUR Cosmic Environment (RESOURCE) project, funded by the Solar System Exploration Research Virtual Institute (SSERVI) program, includes a task to demonstrate the end-to-end process of water extraction, capture, purification and electrolysis to produce pure/dry oxygen gas sourced from an icy regolith mixture. Water Purification: The requirements for water purity are driven by the type of water electrolyzer used. For example, the water electrolyzer currently used on the International Space Station is based on proton ex-change membrane (PEM) technology. PEM-based electrolyzers require water to be ultrapure and deionized (>10 MegaOhm-cm) so that electrical conductivity is limited to the membranes themselves, where electrical current is used to convert H2O into H2 and O2.. A practical first step toward purifying water that is sourced from a lunar PSR is to use freeze distillation to separate water from other volatiles2. A sub-micronic filter can also be used to ensure that a minimal amount of dust is present in any lunar water that is captured. The combination of freeze distillation and sub-micronic filtration will result in relatively pure water but would require a deionization step if being fed into a PEM electrolyzer. Water Electrolysis: An alternative to PEM electrolysis is to use a Solid Oxide Electrolyzer (SOE). This technology operates at a much higher operating temperature (~800oC) and has a limited pressure range but does not require water to be ultrapure and deionized. Another advantage of SOE technology is that it produces pure dry oxygen gas without the need of an additional drying step. PEM electrolyzers produce humid oxygen gas and the humidity must be removed prior to liquefaction. Assessment: In order to compare PEM and SOE technologies side-by-side, they must be compared at a system level that includes water purification and gas drying steps. Engineers at the Johnson Space Center up-dated and utilized a detailed In-Situ Resource Utilization (ISRU) system model to compare and select the best option for the RESOURCE project which will conclude with a laboratory demonstration of the process of producing pure/dry oxygen from an icy regolith mixture in 2025.

ISRU↗

Energy Storage Technology Development for Space Exploration

The National Aeronautics and Space Administration is developing battery and fuel cell technology to meet the expected energy storage needs of human exploration systems. Improving battery performance and safety for human missions enhances a number of exploration systems, including un-tethered extravehicular activity suits and transportation systems including landers and rovers. Similarly, improved fuel cell and electrolyzer systems can reduce mass and increase the reliability of electrical power, oxygen, and water generation for crewed vehicles, depots and outposts. To achieve this, NASA is developing non-flow-through proton-exchange-membrane fuel cell stacks, and electrolyzers coupled with low permeability membranes for high pressure operation. The primary advantage of this technology set is the reduction of ancillary parts in the balance-of-plant fewer pumps, separators and related components should result in fewer failure modes and hence a higher probability of achieving very reliable operation, and reduced parasitic power losses enable smaller reactant tanks and therefore systems with lower mass and volume. Key accomplishments over the past year include the fabrication and testing of several robust, small-scale non-flow-through fuel cell stacks that have demonstrated proof-of-concept. NASA is also developing advanced lithium-ion battery cells, targeting cell-level safety and very high specific energy and energy density. Key accomplishments include the development of silicon composite anodes, lithiatedmixed- metal-oxide cathodes, low-flammability electrolytes, and cell-incorporated safety devices that promise to substantially improve battery performance while providing a high level of safety.

Mercer, Carolyn R.↗

Microgravity Liquid-Gas Two-Phase Flow: Review of Pressure Drop and Heat Transfer Correlations and Guidelines for Equipment Operability

In this report we have catalogued the flow regimes observed in microgravity, summarized correlations for the pressure drop and rate of heat transfer that are commonly used, and discuss the validation of a few correlations from available experimental results. Two-phase flow through some specific components such as bends, tees, filters and pumps are discussed from a physical perspective to guide the designer on how reduced gravity might affect their performance. Phase separation in zero gravity is addressed through the behavior and basic design concepts for devices based on passive centrifugal action, capillary forces, gas extraction through a membrane installed in a channel wall and the use of a syringe with a perforated piston to remove bubbles from small liquid volumes. We address the common instabilities that develop in flow loops owing exclusively to the two-phase nature of the flow, e.g., Ledinegg instability and concentration waves. Finally we briefly review flow metering and gauging; two-phase flow through porous media, where pressure drop and flow regime map correlations in zero-g are a current research topic; and basic operation principles of heat pipes and capillary pumped loops.

liquid-gas↗

Biasable, Balanced, Fundamental Submillimeter Monolithic Membrane Mixer

This device is a biasable, submillimeter-wave, balanced mixer fabricated using JPL s monolithic membrane process a simplified version of planar membrane technology. The primary target application is instrumentation used for analysis of atmospheric constituents, pressure, temperature, winds, and other physical and chemical properties of the atmospheres of planets and comets. Other applications include high-sensitivity gas detection and analysis. This innovation uses a balanced configuration of two diodes allowing the radio frequency (RF) signal and local oscillator (LO) inputs to be separated. This removes the need for external diplexers that are inherently narrowband, bulky, and require mechanical tuning to change frequency. Additionally, this mixer uses DC bias-ability to improve its performance and versatility. In order to solve problems relating to circuit size, the GaAs membrane process was created. As much of the circuitry as possible is fabricated on-chip, making the circuit monolithic. The remainder of the circuitry is precision-machined into a waveguide block that holds the GaAs circuit. The most critical alignments are performed using micron-scale semiconductor technology, enabling wide bandwidth and high operating frequencies. The balanced mixer gets superior performance with less than 2 mW of LO power. This can be provided by a simple two-stage multiplier chain following an amplifier at around 90 GHz. Further, the diodes are arranged so that they can be biased. Biasing pushes the diodes closer to their switching voltage, so that less LO power is required to switch the diodes on and off. In the photo, the diodes are at the right end of the circuit. The LO comes from the waveguide at the right into a reduced-height section containing the diodes. Because the diodes are in series to the LO signal, they are both turned on and off simultaneously once per LO cycle. Conversely, the RF signal is picked up from the RF waveguide by the probe at the left, and flows rightward to the diodes. Because the RF is in a quasi- TEM (suspended, microstrip-like) mode, it impinges on the diodes in an anti-parallel mode that does not couple to the waveguide mode. This isolates the LO and RF signals. This operation is similar to a cross-bar mixer used at low frequencies, except the RF signal enters through the back-short end of the waveguide rather than through the side. The RF probe also conveys the down-converted intermediate frequency (IF) signal out to an off-chip circuit board through a simple LC low-pass filter to the left as indicated. The bias is brought to the diodes through a bypass capacitor at the top.

Siegel, Peter↗

Small, low cost, artificial kidney

Disposable hemodialyzer is described that can be used at home by non-medically trained personnel. Short lengths of semipermeable membrane tubes are arranged in parallel, supported by plastic mesh and encased in epoxy at ends. Tubes are connected to input and output blood manifolds which are separated by dialysate chamber. Daily dialysis requires only two hours or less.

Lavender, A. R.↗

Forming "dynamic" membranes on stainless steel

"Dynamic" zirconium polyacrylic membrane is formed directly on stainless steel substrate without excessive corrosion of steel. Membrane is potentially useful in removal of contaminated chemicals from solution through reversed osmosis. Application includes use in filtration and desalination equipment, and in textile industry for separation of dyes from aqueous solvents.

Brandon, C. A.↗

Electrochemical Cell for Obtaining Oxygen from Carbon Dioxide Atmospheres

To support human life on the Martian surface, an electrochemical device will be required to obtain oxygen from the carbon dioxide rich atmosphere. The electrolyte employed in such a device must be constructed from extremely thin, dense membranes to efficiently acquire the oxygen necessary to support life. A forming process used industrially in the production of multilayer capacitors and electronic substrates was adapted to form the thin membranes required. The process, known as the tape casting, involves the suspension consisting of solvents and binders. The suspension is passed under a blade, resulting in the production of ceramic membranes between 0.1 and 0.5 mm thick. Once fired, the stabilized zirconia membranes were assembled into the cell design by employing a zirconium phosphate solution as the sealing agent. The resulting ceramic-to-ceramic seals were found to be structurally sound and gas-tight. Furthermore, by using a zirconia-based solution to assemble the cell, the problem of a thermal expansion mismatch was alleviated. By adopting an industrial forming process to produce thin membranes, an electrochemical cell for obtaining oxygen from carbon dioxide was produced. The proposed cell design is unique in that it does not require a complicated manifold system for separating the various gases present in this process, nor does it require a series of complex electrical connections. Thus, the device can reliably obtain the vital oxygen supply from the toxic carbon dioxide atmosphere.

Hooker, Matthew↗

Adjustable steam producing flexible orifice independent of fluid pressure

A self-adjusting choke for a fluids nozzle includes a membrane constructed of a single piece of flexible or elastic material. This flexible material is shaped to fit into the outlet of a nozzle. The body of the membrane has at least two flow channels, from one face to the other, which directs two streams of water to cross at the opening of the nozzle or at some point beyond. The elasticity and thickness of the membrane is selected to match the range of expected pressures and fluid velocities. The choke may have more than two flow channels, as long as they are aligned adjacent to one another and directed towards each other at the exit face. In a three orifice embodiment, one is directed upward, one is directed downward, and the one in the middle is directed forward. In this embodiment all three fluid streams intersect at some point past the nozzle opening. Under increased pressure the membrane will deform causing the orifices to realign in a more forward direction, causing the streams to intersect at a smaller angle. This reduces the force with which the separate streams impact each other, still allowing the separate streams to unify into a single stable spiralling stream in spite of the increased pressure.

Morrison, Andrew D.↗

Quality Control Method for a Micro-Nano-Channel Microfabricated Device

A variety of silicon-fabricated devices is used in medical applications such as drug and cell delivery, and DNA and protein separation and analysis. When a fluidic device inlet is connected to a compressed gas reservoir, and the outlet is at a lower pressure, a gas flow occurs through the membrane toward the outside. The method relies on the measurement of the gas pressure over the elapsed time inside the upstream and downstream environments. By knowing the volume of the upstream reservoir, the gas flow rate through the membrane over the pressure drop can be calculated. This quality control method consists of measuring the gas flow through a device and comparing the results with a standard curve, which can be obtained by testing standard devices. Standard devices can be selected through a variety of techniques, both destructive and nondestructive, such as SEM, AFM, and standard particle filtration.

Grattoni, Alessandro↗