Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “medical image processing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

TU-EF-BRA-04: Into 2, 3, and 4 Dimensions

NMR, and Proton Density MRI of the 1D Patient - Anthony Wolbarst Net Voxel Magnetization, m(x,t). T1-MRI; The MRI Device - Lisa Lemen ‘Classical’ NMR; FID Imaging in 1D via k-Space - Nathan Yanasak Spin-Echo; S-E/Spin Warp in a 2D Slice - Ronald Price Magnetic resonance imaging not only reveals the structural, anatomic details of the body, as does CT, but also it can provide information on the physiological status and pathologies of its tissues, like nuclear medicine. It can display high-quality slice and 3D images of organs and vessels viewed from any perspective, with resolution better than 1 mm. MRI is perhaps most extraordinary and notable for the plethora of ways in which it can create unique forms of image contrast, reflective of fundamentally different biophysical phenomena. As with ultrasound, there is no risk from ionizing radiation to the patient or staff, since no X-rays or radioactive nuclei are involved. Instead, MRI harnesses magnetic fields and radio waves to probe the stable nuclei of the ordinary hydrogen atoms (isolated protons) occurring in water and lipid molecules within and around cells. MRI consists, in essence, of creating spatial maps of the electromagnetic environments around these hydrogen nuclei. Spatial variations in the proton milieus can be related to clinical differences in the biochemical and physiological properties and conditions of the associated tissues. Imaging of proton density (PD), and of the tissue proton spin relaxation times known as T1 and T2, all can reveal important clinical information, but they do so with approaches so dissimilar from one another that each is chosen for only certain clinical situations. T1 and T2 in a voxel are determined by different aspects of the rotations and other motions of the water and lipid molecules involved, as constrained by the local biophysical surroundings within and between its cells – and they, in turn, depend on the type of tissue and its state of health. Three other common applications of MRI exploit its capability to detect and image distinct movements of fluids: MR angiography (MRA), which rivals CT angiography but often requires no contrast medium, monitors the bulk flow of blood; functional MRI ( f MRI), distinguishes the perfusion of oxygenated blood from that of de-oxygenated, and lights up parts of the brain that are activated by a stimulus, rather like PET; and diffusion tensor imaging (DTI) indicates the diffusion of free water along tracts of axons, thereby bringing nerve trunks into view. There are variants on all of these themes, and on others as well. Magnetic Resonance Spectroscopy (MRS), for example, can perform non-invasive ‘virtual biopsies’ that allow identification of certain cancers and other lesions. And an MRI-guided needle biopsy can sample brain tissue from a region only millimeters in dimensions. MRI, however, involves deeper and more complex aspects of physics, technology, and biology than do most other imaging modalities, and it is widely considered to be correspondingly more difficult to learn. We could probably cover all of this rather comprehensively if we had 50 hours available rather than 2 ̶ but, to paraphrase a former Secretary of Defense, you tell your story in the time you have allotted. The four presenters and another physicist, Kevin King from GE, have combined their efforts to co-author a single slide show that describes essentials of MRI as simply as possible. It is obviously far from thorough, but hopefully it will succeed in explaining some of the basics in a simplified but still valid fashion; in providing a taste of the numerous capabilities and complexities of the modality; and in whetting your appetite to learn more. Part I. NMR, and Proton Density MRI of the 1D Patient (Wolbarst), begins with an introductory case study that illustrates a half dozen ways in which MRI provides valuable clinical information. It then explores the nuclear magnetic resonance (NMR) phenomenon, which underlies MRI. NMR can be introduced with either of two approaches. In the first, one thinks (loosely) of the nuclei of hydrogen atoms as (rotating and charged and therefore) magnetic objects, whose spin-axes tend to align in a strong external magnetic field, much like a compass needle. As with the Bohr atom, this spin-up/spin-down picture is a highly abridged version of the full quantum mechanical treatment, but still it leads to some useful, legitimate pictures of the NMR process occurring within a voxel: When RF photons of the correct (Larmor) frequency elevate protons in a fixed magnetic field out of their lower-energy spin state into the upper, the NMR phenomenon is indicated by the detectable absorption of RF power. With the addition of a linear gradient field along a multi-voxel, one-dimensional patient/phantom, as well, we can determine the water content of each compartment – an example of a real MRI study, albeit in 1D. Part I concludes with a discussion of the net magnetization at position x, m0(x), under conditions of dynamic thermal equilibrium, which leads into: Part II. Net Voxel Magnetization, m(x,t); T1-MRI; The MRI Device (Lemen), investigates the biophysics of the form of proton spin relaxation process characterized by the time T1. It then moves on to the creation of an MR image that displays the spatial variation in the values of this clinically relevant parameter, again in 1D. Finally, the design and workings of a clinical MRI machine are sketched, in preparation for: Part III. ‘Classical’ NMR; FID Imaging in 1D via k-Space (Yanasak) presents the second standard approach to NMR and MRI, the classical model. It focuses on the time dependence of the net nuclear magnetization, m(x,t), the overall magnetic field generated by the cohort of protons in the voxel at position x. Quite remarkably, this nuclear net magnetization itself acts in a strong magnetic field like a gyroscope in a gravitational field. This tack is better for explaining Free Induction Decay (FID), which involves a brief introduction to the Fourier transform and k-space. This leads to conventional Spin-Echo (S-E) reconstruction techniques for creating clinical images from raw data, and sets the stage for: Part IV. Spin-Echo; S-E / Spin Warp in a 2D Slice (Price) discusses application of the S- E sequence of radiofrequency pulses and gradient magnetic fields to the 1D patient. T2 is introduced but not explained. This Part also considers how to manipulate the image acquisition parameters so as to generate clinical pictures with contrast dominated by spatial variations in PD, T1, or T2. We conclude by demonstrating the spin-warp approach to imaging in 2D with a simple 2×2, 4-voxel example. Much of this material is presented in more detail in the chapter “MRI of the One-dimensional Patient, Part I”, in Advances in Medical Physics, Vol 5 (2014). Copies are on display at the Medical Physics Publishing booth. Learning Objectives: The participant will learn about the processes of NMR and T1 spin relaxation in a tissue voxel in a uniform magnetic field. The participant will learn about combining spin-up/spin-down NMR and T1 processes with a linear gradient to effect frequency-encoding of voxel spatial position. This approach can be used to create proton density and T1 MRI maps, respectively, of the contents of multi-voxel 1D phantoms. The participant will learn about how the ‘classical’ model of NMR it can generate Free Induction Decay (FID) images of 1D phantoms, which involves the use of the Fourier transform in k-space. This can lead simply into standard Spin-Echo images. The participant will learn about extending Spin-Echo imaging into 2 and more dimensions.

60 APPLIED LIFE SCIENCES↗

Ultrasonic Measurements of Temperature Profile and Heat Fluxes in Coal-Fired Power Plants (Final Report)

Many industrial processes are inaccessible or inhospitable to characterization by traditional temperature measurement methods, such as thermocouples, especially over prolonged exposure to harsh environments. Ultrasound is an established characterization technology with diverse applications ranging from medical imaging to therapies to flaw detection to nondestructive evaluation. Ultrasound may characterize solid materials and components noninvasively as a nondestructive evaluation modality and obtain internal measurements of material properties. For example, the speed of ultrasound propagation changes with Young’s modulus and Poisson’s ratio, which can be found from its measurements. Traditional ultrasonic characterization assumes all material properties remain constant with the position. When this assumption holds, a property of interest may be measured by relating it to the speed of ultrasound propagation (or a speed of sound, SOS) and measuring the SOS by timing the ultrasound propagation through a known distance. However, when a property of interest is spatially distributed, the propagation time depends on the SOS changing with the position along the ultrasound propagation path. The multiple temperature distributions may lead to an identical time of flight (TOF). Temperature is one property that impacts the speed of ultrasound and often cannot be assumed to remain constant with the position. Previously, in the context of temperature, we addressed the challenge of ultrasonic characterization of spatially distributed properties by developing a method for measuring segmental temperature distributions (MSTD). This method divides the ultrasonic propagation into segments bound by echogenic features. These features provide ultrasonic interfaces where some energy is reflected toward the receiving transducer, and the rest continues through the medium. The time-of-flight between the echoes reflected from echogenic features characterizes the spatial distribution in the properties of interest in the corresponding segment of the ultrasonic propagation path. This project demonstrated the application of the MSTD method in industrial conditions of the coal-fired power plant. We implemented the MSTD using metals and alloys waveguides, which may be the existing structure for which the temperature distribution is characterized or purposefully designed waveguides added to the structure by welding or other means specifically to quantify thermal properties using the MSTD method. Previous iterations of the MSTD method used ceramic and cementitious waveguides, which significantly attenuate ultrasound. On the other hand, low attenuation in metallic waveguides creates interactions between echogenic features which compilates the signal analysis in the segmental TOF measurements. We have established the WG design principles that minimize the interferences between trailing and primary echoes and, in some cases, eliminate them. The waveguides in which echoes do not interfere improve the timing accuracy and the robustness of ultrasonic measurements of the spatial distributions in material properties. Our emphasis remained on the estimation of the temperature distributions. We have developed general recommendations for designing ultrasonically segmented waveguides with the reduced influence of trailing echoes. Two of our waveguide designs were tested in the industry. The first waveguide was designed for insertion into a combustion zone of the utility-scale coal-fired power plant boiler. The second design allows the characterization of temperature distribution in the direction normal to the boiler’s water wall, a large heat exchanger converting the chemical energy released during combustion to the steam driving the electrical power generation turbines. These waveguides were designed to operate within a restrictive space of thermally insulated water wall and incorporate densely located echogenic features while combatting the influence of trailing echoes. The project has successfully demonstrated the feasibility of using the developed method for accurate, continuous, and robust temperature measurements in extreme environments of power generation and other industrial processes. It, therefore, has achieved its overarching goal of advancing the technology readiness level of the novel Ultrasound Measurements of Segmental Temperature Distribution (US-MSTD) method for real-time measurements of the temperature distribution and heat fluxes closer to commercial availability, developing a prototype multipoint measurement system, and validating its performance on coal-fired utility boilers. The success of this project was achieved in collaboration with the power generator, Rocky Mountain Power, and set the stage for the transfer of this technology from the laboratory to the industry.

01 COAL, LIGNITE, AND PEAT↗

SU-D-18A-02: Towards Real-Time On-Board Volumetric Image Reconstruction for Intrafraction Target Verification in Radiation Therapy

Purpose: To expedite on-board volumetric image reconstruction from limited-angle kV—MV projections for intrafraction verification. Methods: A limited-angle intrafraction verification (LIVE) system has recently been developed for real-time volumetric verification of moving targets, using limited-angle kV—MV projections. Currently, it is challenged by the intensive computational load of the prior-knowledge-based reconstruction method. To accelerate LIVE, we restructure the software pipeline to make it adaptable to model and algorithm parameter changes, while enabling efficient utilization of rapidly advancing, modern computer architectures. In particular, an innovative two-level parallelization scheme has been designed: At the macroscopic level, data and operations are adaptively partitioned, taking into account algorithmic parameters and the processing capacity or constraints of underlying hardware. The control and data flows of the pipeline are scheduled in such a way as to maximize operation concurrency and minimize total processing time. At the microscopic level, the partitioned functions act as independent modules, operating on data partitions in parallel. Each module is pre-parallelized and optimized for multi-core processors (CPUs) and graphics processing units (GPUs). Results: We present results from a parallel prototype, where most of the controls and module parallelization are carried out via Matlab and its Parallel Computing Toolbox. The reconstruction is 5 times faster on a data-set of twice the size, compared to recently reported results, without compromising on algorithmic optimization control. Conclusion: The prototype implementation and its results have served to assess the efficacy of our system concept. While a production implementation will yield much higher processing rates by approaching full-capacity utilization of CPUs and GPUs, some mutual constraints between algorithmic flow and architecture specifics remain. Based on a careful analysis of the prototype performance, it will be feasible to resolve such issues through appropriate algorithmic modifications or special-purpose hardware, thus enabling target verification in seconds with the LIVE system. This work was partially supported by a research grant from Varian Medical Systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electrochemical hydrogen isotope fractionation - fundamental insights leading to process scale up

Introduction Deuterium and tritium, the two isotopes of hydrogen besides protium, are utilized in many industries. Deuterium is routinely used as a nuclear reactor moderator and molecular labeling agent, while tritium is used as an autoradiography label in medical imaging, and in an emerging market for self-powered lighting for watches, exit signs, firearm night-sights and future fusion fuel. Tritium is produced naturally at very low steady-state levels due to cosmic rays, natural nuclear decay reactions, as well as commercial nuclear fission reactors, and terrestrial nuclear testing conducted primarily in the mid-twentieth century. Tritium often accumulates in the heavy water used in nuclear fission reactors and sometimes appears in groundwater near nuclear reactors due to slight leakage from water sources in the reactor. Because of the health and environmental impacts from tritium leaking into the water sources, as well as the value of this precious material, it is desirable to remove and recover as much tritium as reasonably possible from contaminated water.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SU-F-E-10: Student-Driven Exploration of Radiographic Material Properties, Phantom Construction, and Clinical Workflows Or: The Extraordinary Life of CANDY MAN

Purpose: To develop a hands-on learning experience that explores the radiological and structural properties of everyday items and applies this knowledge to design a simple phantom for radiotherapy exercises. Methods: Students were asked to compile a list of readily available materials thought to have radiation attenuation properties similar to tissues within the human torso. Participants scanned samples of suggested materials and regions of interest (ROIs) were used to characterize bulk attenuation properties. Properties of each material were assessed via comparison to a Gammex Tissue characterization phantom and used to construct a list of inexpensive near-tissue-equivalent materials. Critical discussions focusing on samples found to differ from student expectations were used to revise and narrow the comprehensive list. From their newly acquired knowledge, students designed and constructed a simple thoracic phantom for use in a simulated clinical workflow. Students were tasked with setting up the phantom and acquiring planning CT images for use in treatment planning and dose delivery. Results: Under engineer and physicist supervision, students were trained to use a CT simulator and acquired images for approximately 60 different foodstuffs, candies, and household items. Through peer discussion, students gained valuable insights and were made to review preconceptions about radiographic material properties. From a subset of imaged materials, a simple phantom was successfully designed and constructed to represent a human thorax. Students received hands-on experience with clinical treatment workflows by learning how to perform CT simulation, create a treatment plan for an embedded tumor, align the phantom for treatment, and deliver a treatment fraction. Conclusion: In this activity, students demonstrated their ability to reason through the radiographic material selection process, construct a simple phantom to specifications, and exercise their knowledge of clinical workflows. Furthermore, the enjoyable and inexpensive nature of this project proved to attract participant interest and drive creative exploration. Mahon and Riblett have nothing to disclose; Hugo has a research agreement with Phillips Medical systems, a license agreement with Varian Medical Systems, research grants from the National Institute of Health. Authors do not have any potential conflicts of interest to disclose.

60 APPLIED LIFE SCIENCES↗

MO-FG-303-04: A Smartphone Application for Automated Mechanical Quality Assurance of Medical Accelerators

Purpose: The mechanical quality assurance (QA) of medical accelerators consists of a time consuming series of procedures. Since most of the procedures are done manually – e.g., checking gantry rotation angle with the naked eye using a level attached to the gantry –, it is considered to be a process with high potential for human errors. To remove the possibilities of human errors and reduce the procedure duration, we developed a smartphone application for automated mechanical QA. Methods: The preparation for the automated process was done by attaching a smartphone to the gantry facing upward. For the assessments of gantry and collimator angle indications, motion sensors (gyroscope, accelerator, and magnetic field sensor) embedded in the smartphone were used. For the assessments of jaw position indicator, cross-hair centering, and optical distance indicator (ODI), an optical-image processing module using a picture taken by the high-resolution camera embedded in the smartphone was implemented. The application was developed with the Android software development kit (SDK) and OpenCV library. Results: The system accuracies in terms of angle detection error and length detection error were < 0.1° and < 1 mm, respectively. The mean absolute error for gantry and collimator rotation angles were 0.03° and 0.041°, respectively. The mean absolute error for the measured light field size was 0.067 cm. Conclusion: The automated system we developed can be used for the mechanical QA of medical accelerators with proven accuracy. For more convenient use of this application, the wireless communication module is under development. This system has a strong potential for the automation of the other QA procedures such as light/radiation field coincidence and couch translation/rotations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-speed Synchrotron X-ray Imaging of Laser Powder Bed Fusion Process

In additive manufacturing (AM) processes, materials are selectively added in layer-wise fashion to build three-dimensional objects. This approach provides several advantages over conventional manufacturing, including the ability to manufacture complex parts, design flexibility, shorter lead times, reduced inventory of spares, and on-demand manufacturing [1]. With these advantages, applications of AM are increasing rapidly in the medical, aerospace, automobile, and defense industries [2, 3]. Currently, laser powder bed fusion (LPBF) is the most extensively used AM technique for manufacturing metal parts. In a typical LPBF process, a high-power laser beam is scanned across a thin layer of powder, melting and subsequently fusing it to the previous layer. Highly transient interactions between the laser, powder particles, and the bottom layer lead to defects in the AM materials. These defects include porosity, residual stresses, surface roughness, and undesirable microstructures [1, 4]. Additionally, several in situ techniques have been developed to capture these interactions in real time, including high-speed visible light and infra-red imaging [5]. However these techniques are limited to surface observations. Most of the important phenomena that govern the quality of the AM parts, such as dynamics of the vapor depression and melt pool, occur sub-surface and hence cannot be captured using traditional optical techniques. Recently, a synchrotron-based high-speed X-ray imaging technique has been developed to record the sub-surface dynamics of metallic materials during the LPBF process. The unprecedented spatial and temporal resolutions afforded by the synchrotron sources allow direct observation of many important phenomena in AM for the first time [6–9]. Further, high-speed X-ray diffraction and optical imaging techniques are also being applied to capture the crystallographic and thermal information of the material, respectively, as they undergo melting, solidification, and cooling [6, 9]. In this contribution, we introduce the recent developments at the Advanced Photon Source (APS) for in situ and operando study of LPBF processes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Processing of Image Data by Integrated Circuits

Sensors combined with logic and memory circuitry. Cross-correlation of two inputs accomplished by transversal filter. Position of image taken to point where image and template data yield maximum value correlation function. Circuit used for controlling robots, medical-image analysis, automatic vehicle guidance, and precise pointing of scientific cameras.

Armstrong, R. W.↗

TU-G-303-00: Radiomics: Advances in the Use of Quantitative Imaging Used for Predictive Modeling

‘Radiomics’ refers to studies that extract a large amount of quantitative information from medical imaging studies as a basis for characterizing a specific aspect of patient health. Radiomics models can be built to address a wide range of outcome predictions, clinical decisions, basic cancer biology, etc. For example, radiomics models can be built to predict the aggressiveness of an imaged cancer, cancer gene expression characteristics (radiogenomics), radiation therapy treatment response, etc. Technically, radiomics brings together quantitative imaging, computer vision/image processing, and machine learning. In this symposium, speakers will discuss approaches to radiomics investigations, including: longitudinal radiomics, radiomics combined with other biomarkers (‘pan-omics’), radiomics for various imaging modalities (CT, MRI, and PET), and the use of registered multi-modality imaging datasets as a basis for radiomics. There are many challenges to the eventual use of radiomics-derived methods in clinical practice, including: standardization and robustness of selected metrics, accruing the data required, building and validating the resulting models, registering longitudinal data that often involve significant patient changes, reliable automated cancer segmentation tools, etc. Despite the hurdles, results achieved so far indicate the tremendous potential of this general approach to quantifying and using data from medical images. Specific applications of radiomics to be presented in this symposium will include: the longitudinal analysis of patients with low-grade gliomas; automatic detection and assessment of patients with metastatic bone lesions; image-based monitoring of patients with growing lymph nodes; predicting radiotherapy outcomes using multi-modality radiomics; and studies relating radiomics with genomics in lung cancer and glioblastoma. Learning Objectives: Understanding the basic image features that are often used in radiomic models. Understanding requirements for reliable radiomic models, including robustness of metrics, adequate predictive accuracy, and generalizability. Understanding the methodology behind radiomic-genomic (’radiogenomics’) correlations. Research supported by NIH (US), CIHR (Canada), and NSERC (Canada)

60 APPLIED LIFE SCIENCES↗

TU-G-303-02: Robust Radiomics Methods for PET and CT Imaging

‘Radiomics’ refers to studies that extract a large amount of quantitative information from medical imaging studies as a basis for characterizing a specific aspect of patient health. Radiomics models can be built to address a wide range of outcome predictions, clinical decisions, basic cancer biology, etc. For example, radiomics models can be built to predict the aggressiveness of an imaged cancer, cancer gene expression characteristics (radiogenomics), radiation therapy treatment response, etc. Technically, radiomics brings together quantitative imaging, computer vision/image processing, and machine learning. In this symposium, speakers will discuss approaches to radiomics investigations, including: longitudinal radiomics, radiomics combined with other biomarkers (‘pan-omics’), radiomics for various imaging modalities (CT, MRI, and PET), and the use of registered multi-modality imaging datasets as a basis for radiomics. There are many challenges to the eventual use of radiomics-derived methods in clinical practice, including: standardization and robustness of selected metrics, accruing the data required, building and validating the resulting models, registering longitudinal data that often involve significant patient changes, reliable automated cancer segmentation tools, etc. Despite the hurdles, results achieved so far indicate the tremendous potential of this general approach to quantifying and using data from medical images. Specific applications of radiomics to be presented in this symposium will include: the longitudinal analysis of patients with low-grade gliomas; automatic detection and assessment of patients with metastatic bone lesions; image-based monitoring of patients with growing lymph nodes; predicting radiotherapy outcomes using multi-modality radiomics; and studies relating radiomics with genomics in lung cancer and glioblastoma. Learning Objectives: Understanding the basic image features that are often used in radiomic models. Understanding requirements for reliable radiomic models, including robustness of metrics, adequate predictive accuracy, and generalizability. Understanding the methodology behind radiomic-genomic (’radiogenomics’) correlations. Research supported by NIH (US), CIHR (Canada), and NSERC (Canada)

60 APPLIED LIFE SCIENCES↗

TU-G-303-03: Machine Learning to Improve Human Learning From Longitudinal Image Sets

‘Radiomics’ refers to studies that extract a large amount of quantitative information from medical imaging studies as a basis for characterizing a specific aspect of patient health. Radiomics models can be built to address a wide range of outcome predictions, clinical decisions, basic cancer biology, etc. For example, radiomics models can be built to predict the aggressiveness of an imaged cancer, cancer gene expression characteristics (radiogenomics), radiation therapy treatment response, etc. Technically, radiomics brings together quantitative imaging, computer vision/image processing, and machine learning. In this symposium, speakers will discuss approaches to radiomics investigations, including: longitudinal radiomics, radiomics combined with other biomarkers (‘pan-omics’), radiomics for various imaging modalities (CT, MRI, and PET), and the use of registered multi-modality imaging datasets as a basis for radiomics. There are many challenges to the eventual use of radiomics-derived methods in clinical practice, including: standardization and robustness of selected metrics, accruing the data required, building and validating the resulting models, registering longitudinal data that often involve significant patient changes, reliable automated cancer segmentation tools, etc. Despite the hurdles, results achieved so far indicate the tremendous potential of this general approach to quantifying and using data from medical images. Specific applications of radiomics to be presented in this symposium will include: the longitudinal analysis of patients with low-grade gliomas; automatic detection and assessment of patients with metastatic bone lesions; image-based monitoring of patients with growing lymph nodes; predicting radiotherapy outcomes using multi-modality radiomics; and studies relating radiomics with genomics in lung cancer and glioblastoma. Learning Objectives: Understanding the basic image features that are often used in radiomic models. Understanding requirements for reliable radiomic models, including robustness of metrics, adequate predictive accuracy, and generalizability. Understanding the methodology behind radiomic-genomic (’radiogenomics’) correlations. Research supported by NIH (US), CIHR (Canada), and NSERC (Canada)

60 APPLIED LIFE SCIENCES↗

TU-G-303-04: Radiomics and the Coming Pan-Omics Revolution

‘Radiomics’ refers to studies that extract a large amount of quantitative information from medical imaging studies as a basis for characterizing a specific aspect of patient health. Radiomics models can be built to address a wide range of outcome predictions, clinical decisions, basic cancer biology, etc. For example, radiomics models can be built to predict the aggressiveness of an imaged cancer, cancer gene expression characteristics (radiogenomics), radiation therapy treatment response, etc. Technically, radiomics brings together quantitative imaging, computer vision/image processing, and machine learning. In this symposium, speakers will discuss approaches to radiomics investigations, including: longitudinal radiomics, radiomics combined with other biomarkers (‘pan-omics’), radiomics for various imaging modalities (CT, MRI, and PET), and the use of registered multi-modality imaging datasets as a basis for radiomics. There are many challenges to the eventual use of radiomics-derived methods in clinical practice, including: standardization and robustness of selected metrics, accruing the data required, building and validating the resulting models, registering longitudinal data that often involve significant patient changes, reliable automated cancer segmentation tools, etc. Despite the hurdles, results achieved so far indicate the tremendous potential of this general approach to quantifying and using data from medical images. Specific applications of radiomics to be presented in this symposium will include: the longitudinal analysis of patients with low-grade gliomas; automatic detection and assessment of patients with metastatic bone lesions; image-based monitoring of patients with growing lymph nodes; predicting radiotherapy outcomes using multi-modality radiomics; and studies relating radiomics with genomics in lung cancer and glioblastoma. Learning Objectives: Understanding the basic image features that are often used in radiomic models. Understanding requirements for reliable radiomic models, including robustness of metrics, adequate predictive accuracy, and generalizability. Understanding the methodology behind radiomic-genomic (’radiogenomics’) correlations. Research supported by NIH (US), CIHR (Canada), and NSERC (Canada)

60 APPLIED LIFE SCIENCES↗

TU-G-303-01: Radiomics: Quantitative Imaging in the Service of Improved Treatment Decision Making

‘Radiomics’ refers to studies that extract a large amount of quantitative information from medical imaging studies as a basis for characterizing a specific aspect of patient health. Radiomics models can be built to address a wide range of outcome predictions, clinical decisions, basic cancer biology, etc. For example, radiomics models can be built to predict the aggressiveness of an imaged cancer, cancer gene expression characteristics (radiogenomics), radiation therapy treatment response, etc. Technically, radiomics brings together quantitative imaging, computer vision/image processing, and machine learning. In this symposium, speakers will discuss approaches to radiomics investigations, including: longitudinal radiomics, radiomics combined with other biomarkers (‘pan-omics’), radiomics for various imaging modalities (CT, MRI, and PET), and the use of registered multi-modality imaging datasets as a basis for radiomics. There are many challenges to the eventual use of radiomics-derived methods in clinical practice, including: standardization and robustness of selected metrics, accruing the data required, building and validating the resulting models, registering longitudinal data that often involve significant patient changes, reliable automated cancer segmentation tools, etc. Despite the hurdles, results achieved so far indicate the tremendous potential of this general approach to quantifying and using data from medical images. Specific applications of radiomics to be presented in this symposium will include: the longitudinal analysis of patients with low-grade gliomas; automatic detection and assessment of patients with metastatic bone lesions; image-based monitoring of patients with growing lymph nodes; predicting radiotherapy outcomes using multi-modality radiomics; and studies relating radiomics with genomics in lung cancer and glioblastoma. Learning Objectives: Understanding the basic image features that are often used in radiomic models. Understanding requirements for reliable radiomic models, including robustness of metrics, adequate predictive accuracy, and generalizability. Understanding the methodology behind radiomic-genomic (’radiogenomics’) correlations. Research supported by NIH (US), CIHR (Canada), and NSERC (Canada)

60 APPLIED LIFE SCIENCES↗

Co-Funding for the Conference on Magnetic Resonance in Biological Systems

The XXIst International Conference on Magnetic Resonance in Biological Systems (ICMRBS 2005), '60th anniversary of the discovery of Nuclear Magnetic Resonance,' was held between 16 and 21 January 2005 in Hyderabad, India. The meeting focused on a broad range of magnetic resonance methods as applied to studies of biological processes related to human health. The biennial ICMRBS has become the major venue for discussion of advances in nuclear and electron magnetic resonance (NMR & EMR/EPR) studies of the structure, dynamics, and chemical properties of important classes of biomolecules. Magnetic resonance has become an established tool in structural biology, and its special importance derives from its ability to provide atomic level information. It is becoming increasingly evident that the dynamic features of biomolecules, their intermolecular interactions, and accessible conformations in solution are data of key importance in understanding molecular recognition and function. NMR, which is already contributing to approximately 25% of the new structures being deposited with the Protein Data Bank, is destined to be a major player in the post genomic structure age with its emphasis on structure and function. In-vivo magnetic resonance spectroscopy (MRS) and magnetic resonance imaging (MRI) results shed light on human metabolic processes and on the cellular ramifications of cancer, stroke, cardiovascular disease, and other pathologies. New methodologies in metabonomics may lead to development of new drugs and medical diagnosis. The ICMRBS is the one conference that brings together experts from high-resolution NMR, solid state NMR, EPR, in-vivo MRS and MRI, and developers of instrumentation, techniques, software, and databases. Symposia at this ICMRBS are designed to continue the fruitful cross-fertilization of ideas that has been so successful in driving the spectacular advances in this field. ICMRBS 2005 maintained the traditional format of poster sessions, and plenary lectures that highlight major advances in each of the major areas, and three parallel symposia that focused on particular biological systems, interfacial applications of magnetic resonance, and rapidly advancing technology. Funds provided partial travel support for 33 younger scientists from the U.S. (graduate students, postdoctoral research associates, and beginning faculty), selected from those who submitted accepted posters; 12 of these were invited to contribute oral presentations. Those receiving travel support were selected by a committee composed of the U.S. members of the International Advisory Committee for the meeting. Particular emphasis was placed on facilitating participation of minority and women scientists.

59 BASIC BIOLOGICAL SCIENCES↗

SU-E-T-129: Are Knowledge-Based Planning Dose Estimates Valid for Distensible Organs?

Purpose: Knowledge-based planning programs have become available to assist treatment planning in radiation therapy. Such programs can be used to generate estimated DVHs and planning constraints for organs at risk (OARs), based upon a model generated from previous plans. These estimates are based upon the planning CT scan. However, for distensible OARs like the bladder and rectum, daily variations in volume may make the dose estimates invalid. The purpose of this study is to determine whether knowledge-based DVH dose estimates may be valid for distensible OARs. Methods: The Varian RapidPlan™ knowledge-based planning module was used to generate OAR dose estimates and planning objectives for 10 prostate cases previously planned with VMAT, and final plans were calculated for each. Five weekly setup CBCT scans of each patient were then downloaded and contoured (assuming no change in size and shape of the target volume), and rectum and bladder DVHs were recalculated for each scan. Dose volumes were then compared at 75, 60,and 40 Gy for the bladder and rectum between the planning scan and the CBCTs. Results: Plan doses and estimates matched well at all dose points., Volumes of the rectum and bladder varied widely between planning CT and the CBCTs, ranging from 0.46 to 2.42 for the bladder and 0.71 to 2.18 for the rectum, causing relative dose volumes to vary between planning CT and CBCT, but absolute dose volumes were more consistent. The overall ratio of CBCT/plan dose volumes was 1.02 ±0.27 for rectum and 0.98 ±0.20 for bladder in these patients. Conclusion: Knowledge-based planning dose volume estimates for distensible OARs are still valid, in absolute volume terms, between treatment planning scans and CBCT’s taken during daily treatment. Further analysis of the data is being undertaken to determine how differences depend upon rectum and bladder filling state. This work has been supported by Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

SU-E-T-754: Three-Dimensional Patient Modeling Using Photogrammetry for Collision Avoidance

Purpose: To evaluate photogrammetry for creating a three-dimensional patient model. Methods: A mannequin was configured on the couch of a CT scanner to simulate a patient setup using an indexed positioning device. A CT fiducial was placed on the indexed CT table-overlay at the reference index position. Two dimensional photogrammetry targets were placed on the table in known positions. A digital SLR camera was used to obtain 27 images from different positions around the CT table. The images were imported into a commercial photogrammetry package and a 3D model constructed. Each photogrammetry target was identified on 2 to 5 images. The CT DICOM metadata and the position of the CT fiducial were used to calculate the coordinates of the photogrammetry targets in the CT image frame of reference. The coordinates were transferred to the photogrammetry software to orient the 3D model. The mannequin setup was transferred to the treatment couch of a linear accelerator and positioned at isocenter using in-room lasers. The treatment couch coordinates were noted and compared with prediction. The collision free regions were measured over the full range of gantry and table motion and were compared with predictions obtained using a general purpose polygon interference algorithm. Results: The reconstructed 3D model consisted of 180000 triangles. The difference between the predicted and measured couch positions were 5 mm, 1 mm, and 1 mm for longitudinal, lateral, and vertical, respectively. The collision prediction tested 64620 gantry table combinations in 11.1 seconds. The accuracy was 96.5%, with false positive and negative results occurring at the boundaries of the collision space. Conclusion: Photogrammetry can be used as a tool for collision avoidance during treatment planning. The results indicate that a buffer zone is necessary to avoid false negatives at the boundary of the collision-free zone. Testing with human patients is underway. Research partially supported by a grant from Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

Image features for misalignment correction in medical flat-detector CT

Purpose: Misalignment artifacts are a serious problem in medical flat-detector computed tomography. Generally, the geometrical parameters, which are essential for reconstruction, are provided by preceding calibration routines. These procedures are time consuming and the later use of stored parameters is sensitive toward external impacts or patient movement. The method of choice in a clinical environment would be a markerless online-calibration procedure that allows flexible scan trajectories and simultaneously corrects misalignment and motion artifacts during the reconstruction process. Therefore, different image features were evaluated according to their capability of quantifying misalignment. Methods: Projections of the FORBILD head and thorax phantoms were simulated. Additionally, acquisitions of a head phantom and patient data were used for evaluation. For the reconstruction different sources and magnitudes of misalignment were introduced in the geometry description. The resulting volumes were analyzed by entropy (based on the gray-level histogram), total variation, Gabor filter texture features, Haralick co-occurrence features, and Tamura texture features. The feature results were compared to the back-projection mismatch of the disturbed geometry. Results: The evaluations demonstrate the ability of several well-established image features to classify misalignment. The authors elaborated the particular suitability of the gray-level histogram-based entropy on identifying misalignment artifacts, after applying an appropriate window level (bone window). Conclusions: Some of the proposed feature extraction algorithms show a strong correlation with the misalignment level. Especially, entropy-based methods showed very good correspondence, with the best of these being the type that uses the gray-level histogram for calculation. This makes it a suitable image feature for online-calibration.

60 APPLIED LIFE SCIENCES↗