Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “measurement protocol”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Detector-device-independent quantum key distribution: Security analysis and fast implementation

One of the most pressing issues in quantum key distribution (QKD) is the problem of detector side-channel attacks. To overcome this problem, researchers proposed an elegant “time-reversal” QKD protocol called measurement-device-independent QKD (MDI-QKD), which is based on time-reversed entanglement swapping. However, MDI-QKD is more challenging to implement than standard point-to-point QKD. Recently, an intermediary QKD protocol called detector-device-independent QKD (DDI-QKD) has been proposed to overcome the drawbacks of MDI-QKD, with the hope that it would eventually lead to a more efficient detector side-channel-free QKD system. Here, we analyze the security of DDI-QKD and elucidate its security assumptions. We find that DDI-QKD is not equivalent to MDI-QKD, but its security can be demonstrated with reasonable assumptions. On the more practical side, we consider the feasibility of DDI-QKD and present a fast experimental demonstration (clocked at 625 MHz), capable of secret key exchange up to more than 90 km.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Caveats and limitations of plate reader-based high-throughput kinetic measurements of intracellular calcium levels

Calcium plays a crucial role in virtually all cellular processes, including neurotransmission. The intracellular Ca{sup 2+} concentration ([Ca{sup 2+}]{sub i}) is therefore an important readout in neurotoxicological and neuropharmacological studies. Consequently, there is an increasing demand for high-throughput measurements of [Ca{sup 2+}]{sub i}, e.g. using multi-well microplate readers, in hazard characterization, human risk assessment and drug development. However, changes in [Ca{sup 2+}]{sub i} are highly dynamic, thereby creating challenges for high-throughput measurements. Nonetheless, several protocols are now available for real-time kinetic measurement of [Ca{sup 2+}]{sub i} in plate reader systems, though the results of such plate reader-based measurements have been questioned. In view of the increasing use of plate reader systems for measurements of [Ca{sup 2+}]{sub i} a careful evaluation of current technologies is warranted. We therefore performed an extensive set of experiments, using two cell lines (PC12 and B35) and two fluorescent calcium-sensitive dyes (Fluo-4 and Fura-2), for comparison of a linear plate reader system with single cell fluorescence microscopy. Our data demonstrate that the use of plate reader systems for high-throughput real-time kinetic measurements of [Ca{sup 2+}]{sub i} is associated with many pitfalls and limitations, including erroneous sustained increases in fluorescence, limited sensitivity and lack of single cell resolution. Additionally, our data demonstrate that probenecid, which is often used to prevent dye leakage, effectively inhibits the depolarization-evoked increase in [Ca{sup 2+}]{sub i}. Overall, the data indicate that the use of current plate reader-based strategies for high-throughput real-time kinetic measurements of [Ca{sup 2+}]{sub i} is associated with caveats and limitations that require further investigation. - Research Highlights: > The use of plate readers for high-throughput screening of intracellular Ca{sup 2+} is associated with many pitfalls and limitations. > Single cell fluorescent microscopy is recommended for measurements of intracellular Ca{sup 2+}. > Dual-wavelength dyes (Fura-2) are preferred over single-wavelength dyes (Fluo-4) for measurements of intracellular Ca{sup 2+}. > Probenecid prevents dye leakage but abolishes depolarization-evoked Ca{sup 2+} influx, severely hampering measurements of Ca{sup 2+}. > In general, care should be taken when interpreting data from high-throughput kinetic measurements.

60 APPLIED LIFE SCIENCES↗

Relationship between LIBS Ablation and Pit Volume for Geologic Samples: Applications for in situ Absolute Geochronology

In planetary sciences, in situ absolute geochronology is a scientific and engineering challenge. Currently, the age of the Martian surface can only be determined by crater density counting. However this method has significant uncertainties and needs to be calibrated with absolute ages. We are developing an instrument to acquire in situ absolute geochronology based on the K‐Ar method. The protocol is based on the laser ablation of a rock by hundreds of laser pulses. Laser Induced Breakdown Spectroscopy (LIBS) gives the potassium content of the ablated material and a mass spectrometer (quadrupole or ion trap) measures the quantity of 40Ar released. In order to accurately measure the quantity of released 40Ar in cases where Ar is an atmospheric constituent (e.g., Mars), the sample is first put into a chamber under high vacuum. The 40Arquantity, the concentration of K and the estimation of the ablated mass are the parameters needed to give the age of the rocks. The main uncertainties with this method are directly linked to the measures of the mass (typically some μg) and of the concentration of K by LIBS (up to 10%). Because the ablated mass is small compared to the mass of the sample, and because material is redeposited onto the sample after ablation, it is not possible to directly measure the ablated mass. Our current protocol measures the ablated volume and estimates the sample density to calculate ablated mass. The precision and accuracy of this method may be improved by using knowledge of the sample's geologic properties to predict its response to laser ablation, i.e., understanding whether natural samples have a predictable relationship between laser energy deposited and resultant ablation volume. In contrast to most previous studies of laser ablation, theoretical equations are not highly applicable. The reasons are numerous, but the most important are: a) geologic rocks are complex, polymineralic materials; b) the conditions of ablation are unusual (for example, variable vacuum pressure), and c) the ablation is made with hundreds of successive laser pulses. In this work, we aim to understand the effects that occur on LIBS spectra when a homogeneous rock or a mineral is ablated under high vacuum. Understanding these effects is important to define best practices for LIBS measurements and may lead to improved measurement (or possibly prediction) of the ablated volume. We will describe our laboratory approach and first results, and discuss its utility for situ absolute geochronology campaigns.

Devismes, D.↗

Reducing measurement costs by recycling the Hessian in adaptive variational quantum algorithms

Abstract Adaptive protocols enable the construction of more efficient state preparation circuits in variational quantum algorithms (VQAs) by utilizing data obtained from the quantum processor during the execution of the algorithm. This idea originated with Adaptive Derivative-Assembled Problem-Tailored variational quantum eigensolver (ADAPT-VQE), an algorithm that iteratively grows the state preparation circuit operator by operator, with each new operator accompanied by a new variational parameter, and where all parameters acquired thus far are optimized in each iteration. In ADAPT-VQE and other adaptive VQAs that followed it, it has been shown that initializing parameters to their optimal values from the previous iteration speeds up convergence and avoids shallow local traps in the parameter landscape. However, no other data from the optimization performed at one iteration is carried over to the next. In this work, we propose an improved quasi-Newton optimization protocol specifically tailored to adaptive VQAs. The distinctive feature in our proposal is that approximate second derivatives of the cost function are recycled across iterations in addition to optimal parameter values. We implement a quasi-Newton optimizer where an approximation to the inverse Hessian matrix is continuously built and grown across the iterations of an adaptive VQA. The resulting algorithm has the flavor of a continuous optimization where the dimension of the search space is augmented when the gradient norm falls below a given threshold. We show that this inter-optimization exchange of second-order information leads the approximate Hessian in the state of the optimizer to be consistently closer to the exact Hessian. As a result, our method achieves a superlinear convergence rate even in situations where the typical implementation of a quasi-Newton optimizer converges only linearly. Our protocol decreases the measurement costs in implementing adaptive VQAs on quantum hardware as well as the runtime of their classical simulation.

Ramôa, Mafalda (ORCID:0000000302187801)↗

A Free Spectroscopic Databank of Optical Constants for Use in Optics Education and Modeling: complex refractive index data n and k from 1.0 to 25 um

The reflectance spectra of solid and liquids can be complicated since they depend not only on absorption, but also on the refraction, reflection, and scattering of light, all of which are wavelength dependent. The physical form and morphological effects associated with solid and liquid samples are thus known to affect their reflectance spectra in a non-linear fashion, particularly in the infrared. Measuring the optical constants n(?) and k(?) represents an alternative approach, allowing one to model these many effects and thus requiring fewer laboratory measurements. In this paper an overview is presented of the protocols used to measure the n/k optical constants, particularly for liquids. For the liquids, a multiple path length measurements approach is employed, and in this paper we demonstrate the method to determine the complex optical constants n(?) and k(?) of squalene. The resultant calculated spectra of 1 µm and 100 µm thick layers of squalene on an aluminum substrate as derived from the experimental n(?) and k(?) values are shown to demonstrate such effects. The public availability of the n(?)/k(?) data as well as solids hemispherical reflectance data are also discussed.

optical constants, refractive index, solids, Liqui↗

Reference dosimetry during diagnostic CT examination using XR-QA radiochromic film model

Purpose: The authors applied 2D reference dosimetry protocol for dose measurements using XR-QA radiochromic film model during diagnostic computed tomography (CT) examinations carried out on patients and humanoid Rando phantom. Methods: Response of XR-QA model GAFCHROMIC film reference dosimetry system was calibrated in terms of Air-Kerma in air. Four most commonly used CT protocols were selected on their CT scanner (GE Lightspeed VCT 64), covering three anatomical sites (head, chest, and abdomen). For each protocol, 25 patients ongoing planned diagnostic CT examination were recruited. Surface dose was measured using four or eight film strips taped on patients' skin and on Rando phantom. Film pieces were scanned prior to and after irradiation using Epson Expression 10000XL document scanner. Optical reflectance of the unexposed film piece was subtracted from exposed one to obtain final net reflectance change, which is subsequently converted to dose using previously established calibration curves. Results: The authors' measurements show that body skin dose variation has a sinusoidal pattern along the scanning axis due to the helical movement of the x-ray tube, and a comb pattern for head dose measurements due to its axial movement. Results show that the mean skin dose at anterior position for patients is (51 {+-} 6) mGy, (29 {+-} 11) mGy, (45 {+-} 13) mGy and (38 {+-} 20) mGy for head, abdomen, angio Abdomen, and chest and abdomen protocol (UP position), respectively. The obtained experimental dose length products (DLP) show higher values than CT based DLP taken from the scanner console for body protocols, but lower values for the head protocol. Internal dose measurements inside the phantom's head indicate nonuniformity of dose distribution within scanned volume. Conclusions: In this work, the authors applied an Air-Kerma in air based radiochromic film reference dosimetry protocol for in vivo skin dose measurements. In this work, they employed green channel extracted from the scanned RGB image for dose measurements in the range from 0 to 200 mGy. Measured skin doses and corresponding DLPs were higher than DLPs provided by the CT scanner manufacturer as they were measured on patients' skin.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Dynamic Assimilation Technique measures photosynthetic CO 2 response curves with similar fidelity to steady-state approaches in half the time

The net CO 2 assimilation (A) response to intercellular CO 2 concentration (C i ) is a fundamental measurement in photosynthesis and plant physiology research. The conventional A/C i protocols rely on steady-state measurements and take 15–40 min per measurement, limiting data resolution or biological replication. Additionally, there are several CO 2 protocols employed across the literature, without clear consensus as to the optimal protocol or systematic biases in their estimations. We compared the non-steady-state Dynamic Assimilation Technique (DAT) protocol and the three most used CO 2 protocols in steady-state measurements, and tested whether different CO 2 protocols lead to systematic differences in estimations of the biochemical limitations to photosynthesis. The DAT protocol reduced the measurement time by almost half without compromising estimation accuracy or precision. The monotonic protocol was the fastest steady-state method. Estimations of biochemical limitations to photosynthesis were very consistent across all CO 2 protocols, with slight differences in Rubisco carboxylation limitation. The A/C i curves were not affected by the direction of the change of CO 2 concentration but rather the time spent under triose phosphate utilization (TPU)-limited conditions. Our results suggest that the maximum rate of Rubisco carboxylation (V cmax ), linear electron flow for NADPH supply (J), and TPU measured using different protocols within the literature are comparable, or at least not systematically different based on the measurement protocol used.

54 ENVIRONMENTAL SCIENCES↗

Success of Montreal Protocol Demonstrated by Comparing High-Quality UV Measurements with “World Avoided” Calculations from Two Chemistry-Climate Models

The Montreal protocol on Substances that Deplete the ozone Layer has been hailed as the most successful environmental treaty ever (https://www.unenvironment.org/news-and-stories/story/montreal-protocol-triumph-treaty). Yet, although our main concern about ozone depletion is the subsequent increase in harmful solar UV radiation at the earth’s surface, no studies to date have demonstrated its effectiveness in that regard. Here we use long-term UV Index (UVI) data derived from high-quality UV spectroradiometer measurements to demonstrate its success in curbing increases in UV radiation. Without this landmark agreement, UVi values would have increased at mid-latitude locations by approximately 20% between the early 1990s and today and would approximately quadruple at mid-latitudes by 2100. In contrast, an analysis of UVI data from multiple clean-air sites shows that maximum daily UVI values have remained essentially constant over the last ~20 years in all seasons, and may even have decreased slightly in the southern hemisphere, especially in Antarctica, where effects of ozone depletion were larger. Reconstructions of the UVi from total ozone data show evidence of increasing UVI levels in the 1980s, but unfortunately, there are no high-quality UV measurements available prior to the early 1990s to confirm these increases with direct observations.

UV Index (UVI) data derived from high-quality UV s↗

Chapter 2: Commercial and Industrial Lighting Evaluation Protocol. The Uniform Methods Project: Methods for Determining Energy Efficiency Savings for Specific Measures

The Commercial and Industrial Lighting Evaluation Protocol (the protocol) describes methods to account for gross energy savings resulting from the programmatic installation of efficient lighting equipment in large populations of commercial, industrial, and other nonresidential facilities. This protocol does not address savings resulting from changes in codes and standards, or from education and training activities. A separate Uniform Methods Project (UMP) protocol, Chapter 3: Commercial and Industrial Lighting Controls Evaluation Protocol, addresses methods for evaluating savings resulting from lighting control measures such as adding time clocks, tuning energy management system commands, and adding occupancy sensors.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Determination of Duty Cycle for Energy Storage Systems in a PV Smoothing Application

This report supplements the document, "Protocol for Uniformly Measuring and Expressing the Performance of Energy Storage Systems," issued in a revised version in April 2016 (see [4]), which will include the photovoltaic (PV) smoothing application for an energy storage system (ESS). This report provides the background and documentation associated with the determination of a duty cycle for an ESS operated in a PV smoothing application for the purpose of measuring and expressing ESS performance in accordance with the ESS performance protocol. ACKNOWLEDGEMENTS The authors gratefully acknowledge the support of Dr. Imre Gyuk, program manager for the DOE Energy Storage Systems Program. The authors would also like to express their appreciation to all the stakeholders who participated as members of the PV Smoothing Subgroup. Without their thoughtful input and recommendations, the definitions, metrics, and duty cycle provided in this report would not have been possible. A complete listing of members of the PV Smoothing Subgroup appears in the first chapter of this report. Special recognition should go to the staffs at Pacific Northwest National Laboratory (PNNL) and Sandia National Laboratories (SNL) in collaborating on this effort. In particular, Mr. David Conover and Dr. Vish Viswanathan of PNNL and Dr. Summer Ferreira of SNL were especially helpful in their suggestions for the determination of a duty cycle for the PV Smoothing application.

25 ENERGY STORAGE↗

Determination of Duty Cycle for Energy Storage Systems in a Renewables (Solar) Firming Application

This report supplements the document, “Protocol for Uniformly Measuring and Expressing the Performance of Energy Storage Systems,” issued in a revised version in April 2016, which will include the renewables (solar) firming application for an energy storage system (ESS). This report provides the background and documentation associated with the determination of a duty cycle for an ESS operated in a renewables (solar) firming application for the purpose of measuring and expressing ESS performance in accordance with the ESS performance protocol.

25 ENERGY STORAGE↗

The Uniform Methods Project: Smart Thermostat Evaluation Protocol

A smart thermostat is an internet-connected device that controls home heating, ventilation, and air-conditioning (HVAC) equipment and can automatically adjust temperature set points to optimize performance and achieve energy savings. Smart thermostat features often include two way communication, occupancy detection (such as geofencing and occupancy sensors), schedule learning, and seasonal optimization algorithms. Smart thermostats can control most conventional HVAC systems, including central air conditioners, heat pumps, and forced air furnaces. Several types of residential utility programs offer smart thermostats as replacements measures. Working with smart thermostat vendors, utilities can offer separate optimization programs to produce energy savings beyond those achieved by installing a smart thermostat. From an evaluation perspective, smart thermostat programs have several noteworthy features. First, the energy savings from a smart thermostat may change over the life of the device. As a smart thermostat is connected to the internet, original equipment manufacturers can update the thermostat software to improve the thermostat's energy efficiency. Likewise, users can adjust the thermostat settings and schedules over time in response to changes in weather, thermal comfort, energy prices, or preferences for energy efficiency. Additionally, many thermostat manufacturers offer seasonal optimization programs that recommend changes or make minor, automated adjustments to the thermostat settings to improve energy efficiency. These opt-in programs are now standard offerings for many smart thermostat manufacturers and provided at no additional cost to users. The potential for software updates and continuous optimization and the evolving nature of user interactions mean future energy savings may differ from first-year savings and the energy savings of smart thermostats may need to be evaluated more than once. Second, smart thermostats often have small unit energy savings relative to a home's total energy consumption, especially in comparison to whole- home retrofit programs. This can make it difficult to detect the smart thermostat savings in billing or advanced metering infrastructure (AMI) meter consumption data. For example, as cooling loads in many regions average about 20% of annual electricity consumption, smart thermostat savings of 10% of cooling energy use would equate to a 2% reduction in home electricity consumption. Evaluators should use regression analysis of whole-home billing consumption or advanced metering infrastructure (AMI) meter consumption data to evaluate smart thermostat savings because, as explained at greater length below , these data are usually available to evaluators and regression can control for the impacts of weather and other potentially confounding factors on a home's energy consumption. Finally, as with other energy efficiency programs, participation in smart thermostat programs is self-selective. As discussed at greater length below , smart thermostat participants tend to be, among other things, younger, higher-income, and more likely to adopt electric vehicles (EVs) and internet connected devices than nonparticipants. These differences are often unobservable to the evaluator and correlated with a home's energy consumption, creating the potential for bias in estimating savings. Due to the small unit savings of thermostats, errors and biases from self-selection that may not be very consequential when evaluating a whole- home retrofits (e.g., ±2% of home electricity consumption) can have a major impact when evaluating the savings and cost-effectiveness of smart thermostat programs. A percentage point change in the estimated savings could affect the cost-effectiveness of a program. This means it is important for evaluators to assess and to minimize the potential for error from selection bias in estimating smart thermostat program savings. The Uniform Methods Project provides model protocols for determining energy savings and demand reductions that result from specific energy efficiency measures implemented through state and utility programs. In most cases, the measure protocols are based on a particular option identified by the International Performance Verification and Measurement Protocol ; however, this work provides a more detailed approach to implementing that option. Each chapter is written by technical experts in collaboration with their peers, reviewed by industry experts, and subject to public review and comment. The UMP protocols can be used by utilities, program administrators, public utility commissions, evaluators, and other stakeholders for both program planning and evaluation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Observability and Estimation of Distributed Space Systems via Local Information-Exchange Networks

Spacecraft formation flying involves the coordination of states among multiple spacecraft through relative sensing, inter-spacecraft communication, and control. Most existing formation-flying estimation algorithms can only be supported via highly centralized, all-to-all, static relative sensing. New algorithms are proposed that are scalable, modular, and robust to variations in the topology and link characteristics of the formation exchange network. These distributed algorithms rely on a local information exchange network, relaxing the assumptions on existing algorithms. Distributed space systems rely on a signal transmission network among multiple spacecraft for their operation. Control and coordination among multiple spacecraft in a formation is facilitated via a network of relative sensing and interspacecraft communications. Guidance, navigation, and control rely on the sensing network. This network becomes more complex the more spacecraft are added, or as mission requirements become more complex. The observability of a formation state was observed by a set of local observations from a particular node in the formation. Formation observability can be parameterized in terms of the matrices appearing in the formation dynamics and observation matrices. An agreement protocol was used as a mechanism for observing formation states from local measurements. An agreement protocol is essentially an unforced dynamic system whose trajectory is governed by the interconnection geometry and initial condition of each node, with a goal of reaching a common value of interest. The observability of the interconnected system depends on the geometry of the network, as well as the position of the observer relative to the topology. For the first time, critical GN&C (guidance, navigation, and control estimation) subsystems are synthesized by bringing the contribution of the spacecraft information-exchange network to the forefront of algorithmic analysis and design. The result is a formation estimation algorithm that is modular and robust to variations in the topology and link properties of the underlying formation network.

Fathpour, Nanaz↗

MSR Curation Technology Development – Developing Protocols for Pre-Basic Characterization Measurements

The joint NASA/ESA Mars Sample Return (MSR) campaign could deliver to Earth the first pristine Mar-tian rock and regolith samples, collected by the Mars2020 science mission, Perseverance. In preparation for their arrival, the NASA/ESA Joint Curation Office (JCO) within the Sample Receiving Project (SRP) is developing curation technology needed to perform initial characterization of the samples while isolating samples from the Earth’s biosphere and protecting the samples from terrestrial contamination. (RSTA; Fig. 1). The Mars Sample Return Planning Group 2 (MSPG2) identified methods for achieving an array of potential science objectives for MSR outlined by the International MSR Objectives and Samples Team (iMOST) [1]. One category of methods, called Pre-Basic Characterization, recommends potential analyses that would happen before the Returnable Sample Tube Assemblies (RSTA; Figure 1) are opened: 1) Magnetometer & Magnetic Susceptibility; 2) X-ray Computed Tomography (XCT) Scanner [2]. To be in compliance with planetary protection requirements, and to limit the amount of time sample tubes are out-side of an isolated contamination-controlled environment, secondary containment is necessary. A Sample Tube Isolation Container (STIC) and Secondary Outer Containment Case (SOCC) is currently being developed at NASA JPL under the direction of the SRP JCO.

V Tu↗

Teaching Soil Science in Primary and Secondary Schools

Earth's thin layer of soil is a fragile resource, made up of minerals, organic materials, air, water, and billions of living organisms. Soils plays a variety of critical roles that sustain life on Earth. If we think about soil, we tend to see it first as the source of most of the food we eat and the fibers we use, such as wood and cotton. Few students realize that soils also provide the key ingredients to many of the medicines (including antibiotics), cosmetics, and dyes that we use. Fewer still understand the importance of soils in integrating, controlling, and regulating the movement of air, water, materials, and energy between the hydrosphere, lithosphere, atmosphere, and biosphere. Because soil sustains life, it offers both a context and a natural laboratory for investigating these interactions. The enclosed poster, which integrates soil profiles with typical landscapes in which soils form, can also help students explore the interrelationships of Earth systems and gain an understanding of our soil resources. The poster, produced jointly by the American Geological Institute and the Soil Science Society of America, aims to increase awareness of the importance of soil, as does the GLOBE (Global Learning and Observations To Benefit the Environment) Program. Vice President Al Gore instituted the GLOBE Program on Earth Day of 1993 to increase environmental awareness of individuals throughout the world, contribute to a better scientific understanding of the Earth, and help all students reach higher levels of achievement in science and mathematics. GLOBE functions as a partnership between scientists, students, and teachers in which scientists design protocols for specific measurements they need for their research that can be performed by K-12 students. Teachers are trained in the GLOBE protocols and teach them to their students. Students make the measurements, enter data via the Internet to a central data archive, and the data becomes available to scientists and the general community. Students benefit by having a "hands-on"experience in science, math, and technology, using their local environment as a learning laboratory, as well as contact with scientists and other students around the world. Soil investigations have become an essential component of GLOBE. The protocols that have been developed so far within the GLOBE program include GPS Location, Atmosphere/Climate, Soil Characterization, Soil Moisture and Temperature, Land Cover/Biometry, Hydrology, and Satellite Image Classification. For the GLOBE Soil Characterization Protocol, students explore the physical. chemical, and morphological properties of the soil at their study site. They are asked to dig a pit or use an auger to about 1 meter at at least 2 sites.

Levine, Elissa R.↗

Full waveform analysis for high pressure ultrasonic measurement

In this paper we report a data analysis protocol for ultrasonic velocity measurements carried out in a synchrotron x-ray facility based multi-anvil high-pressure apparatus. Synthetic ultrasonic signals for the time period between echoes from the two ends of the sample assembly are created with a few simple parameters as the echo waveform is modeled by the first echo from the anvil-assembly boundary. Each echo is modeled as a delta function with an amplitude and arrival time and convolved with this waveform. The final waveform, fit to the data, enables analysis of signals with overlapped echoes as they are common in small cell assemblies and high pressure.

47 OTHER INSTRUMENTATION↗

Chemical Modeling of the Reactivity of Short-Lived Greenhouse Gases: A Model Inter-Comparison Prescribing a Well-Measured, Remote Troposphere

We develop a new protocol for merging in situ measurements with 3-D model simulations of atmospheric chemistry with the goal of integrating over the data to identify the most reactive air parcels in terms of tropospheric production and loss of the greenhouse gases ozone and methane. Presupposing that we can accurately measure atmospheric composition, we examine whether models constrained by such measurements agree on the chemical budgets for ozone and methane. In applying our technique to a synthetic data stream of 14,880 parcels along 180W, we are able to isolate the performance of the photochemical modules operating within their global chemistry-climate and chemistry-transport models, removing the effects of modules controlling tracer transport, emissions, and scavenging. Differences in reactivity across models are driven only by the chemical mechanism and the diurnal cycle of photolysis rates, which are driven in turn by temperature, water vapor, solar zenith angle, clouds, and possibly aerosols and overhead ozone, which are calculated in each model. We evaluate six global models and identify their differences and similarities in simulating the chemistry through a range of innovative diagnostics. All models agree that the more highly reactive parcels dominate the chemistry (e.g., the hottest 10% of parcels control 25-30% of the total reactivities), but do not fully agree on which parcels comprise the top 10%. Distinct differences in specific features occur, including the regions of maximum ozone production and methane loss, as well as in the relationship between photolysis and these reactivities. Unique, possibly aberrant, features are identified for each model, providing a benchmark for photochemical module development. Among the 6 models tested here, 3 are almost indistinguishable based on the inherent variability caused by clouds, and thus we identify 4, effectively distinct, chemical models. Based on this work, we suggest that water vapor differences in model simulations of past and future atmospheres may be a cause of the different evolution of tropospheric O3 and CH4, and lead to different chemistry-climate feedbacks across the models.

greenhouse gases↗

"Application of Tunable Diode Laser Spectrometry to Isotopic Studies for Exobiology"

Computer-controlled electrically-activated valves for rapid gas-handling have been incorporated into the Stable Isotope Laser Spectrometer (SILS) which now permits rapid filling and evacuating of the sample and reference gas cells, Experimental protocols have been developed to take advantage of the fast gas handling capabilities of the instrument and to achieve increased accuracy which results from reduced instrumental drift during rapid isotopic ratio measurements. Using these protocols' accuracies of 0.5 del (0.05%) have been achieved in measurements of 13C/12C in carbon dioxide. Using the small stable isotope laser spectrometer developed in a related PIDDP project of the Co-I, protocols for acquisition of rapid sequential calibration spectra were developed which resulted in 0.5 del accuracy also being achieved in this less complex instrument. An initial version of software for automatic characterization of tunable diode lasers has been developed and diodes have been characterized in order to establish their spectral output properties. A new state-of-the-art high operating temperature (200 K) mid infrared diode laser was purchased (through NASA procurement) and characterized. A thermo-electrically cooled mid infrared tunable diode laser system for use with high temperature operation lasers was developed. In addition to isotopic ratio measurements of carbon and oxygen, measurements of a third biologically important element (15N/14N in N2O gas) have been achieved to a preliminary accuracy of about 0.2%. Transfer of the basic SILS technology to the commercial sector is proceeding under an unfunded Space Act Agreement between NASA and SpiraMed, a medical diagnostic instrument company. Two patents have been issued. Foreign patents based on these two US patents have been applied for and are expected to be issued. A preliminary design was developed for a thermo-electrically cooled SILS instruments for application to planetary space flight exploration missions.

Sauke, Todd B.↗