Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “low pressure”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Optimization of Triply Periodic Minimal Surface Heat Exchanger to Achieve Compactness, High Efficiency, and Low-Pressure Drop

With advancements in additive manufacturing (AM) techniques, high-quality triply periodic minimal surface (TPMS) structures can now be produced. TPMS walled heat exchangers (HX) hold significant potential for industrial applications and are receiving increasing attention. This paper explores the impact of various TPMS design variables on flow and thermal performance to optimize TPMS heat exchangers for compactness, high efficiency, and low pressure drop. The design variables examined include the type of TPMS lattice, unit cell size, wall thickness, aspect ratio, TPMS orientation, and equivalent thickness. The study reveals that the flow and heat transfer performance of TPMS structures are significantly affected by these design variables. For the Gyroid, Diamond, and SplitP lattices, performance is nearly identical when the surface-to-volume ratio is kept constant. The average velocity of the fluid in the TPMS HX should be 0.3 m/s. The corresponding Re is between 300~800. Thin wall thickness, small equivalent thickness, and flat lattice configurations can significantly reduce pressure drop while maintaining the overall heat transfer coefficient. Additionally, the angle between the flow direction and TPMS orientation can increase pressure drop. Three aluminum heat exchangers were successfully printed using an AM machine, and testing results are comparable with theoretical prediction.

42 ENGINEERING↗

Detection of tropospheric OH and HO2 by laser-induced fluorescence at low pressure using the 308nm excitation of OH

Laser-induced fluorescence (LIF) spectroscopy is a highly sensitive method for the direct in situ measurement of hydroxyl concentrations in the atmosphere. Its sensitivity and selectivity relies on the intense discrete UV-absorption lines of OH which are strongest around 282nm and 308nm. We have developed a LIF-instrument based on the low-pressure experiment (FAGE). However, we use 308nm instead of 282nm as excitation wavelength for OH, a concept that is also pursued by other groups. One advantage of the longer excitation wavelength is the higher detection sensitivity due to the about 6 times larger effective OH-fluorescence cross-section. Moreover, the O3/H2O-interference (OH self-generation by the laser) is about a factor of 200 smaller at 308nm than at 282nm. This keeps the interference level well below the projected detection limit of 10(exp 5) OH/cm(exp 3). Atmospheric HO2-radicals are detected by chemical conversion of HO2 into OH with NO.

Hofzumahaus, Andreas↗

Single-Particle Studies Reveal a Nanoscale Mechanism for Elastic, Bright, and Repeatable ZnS:Mn Mechanoluminescence in a Low-Pressure Regime

Mechanoluminescent materials, which emit light in response to elastic deformation, are demanded for use as in situ stress sensors. ZnS doped with Mn is known to exhibit one of the lowest reported thresholds for appearance of mechanoluminescence, with repeatable light emission under contact pressure <10 MPa. Here, the physical basis for such behavior remains as yet unclear. Here, reliable microscopic detection of mechanoluminescence of single ZnS:Mn microparticles, in combination with nanoscale structural characterization, provides evidence that the mechanoluminescent properties of these particles result from interplay between a non-centrosymmetric crystal lattice and its defects, viz., dislocations and stacking faults. Statistical analysis of the distributions of mechanoluminescence energy release trajectories reveals two distinct mechanisms of excitation: one attributable to a piezo-phototronic effect and the other due to dislocation motion. At pressures below 8.1 MPa, both mechanisms contribute to mechanoluminescent output, with a dominant contribution from the piezo-phototronic mechanism. In contrast, above 8.1 MPa, dislocation motion is the primary excitation source. For the piezo-phototronic mechanism, we propose a specific model that accounts for elastic ZnS:Mn mechanoluminescence under very low pressure. The charged interfaces in stacking faults lead to the presence of filled traps, which otherwise would be empty in the absence of the built-in electric field. Upon application of external stress, local enhancement of the piezoelectric field at the stacking faults’ interfaces facilitates release of the trapped carriers and subsequent luminescence. This field enhancement explains how <10 MPa pressure produces thousands of photons.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evaluation of Low-Pressure Cold Plasma for Disinfection for ISS Grown Produce and Metallic Instrumentation

Cold plasma (CP) cleaning is a dry, non-thermal process, which can provide broad-spectrum antimicrobial activity yet reportedly causes little to no damage to the object being sanitized. Since cold plasma uses no liquids, it has the distinct advantage when used in microgravity of not having to separate liquids from the item being cleaned. This paper will present results on an effort to use low pressure CP to disinfect or sterilize materials for in space applications. Exposure times from 0 to 60 minutes and pressures ranging from 10 to 100 Pa were used to optimize plasma parameters to achieve acceptable kill rates for 3 bacteria, Bacillus cereus, E. coli and Bacillus pumulis SAFR-32 and one fungi, Aspergillus niger. These tests were done on produce and metal coupons to simulate medical equipment. Produce testing was not successful, with unacceptable kill rates and the produce being negatively impacted by exposure to the plasma. The plasma caused a 5 log reduction in the number of viable bacteria on metal coupon tests, which placed the number of viable bacteria below the detection limit. This is a very promising result showing that sterilization of medical equipment with cold plasma is feasible. Scanning Electron Microscope images were taken before and after exposure. The images after plasma exposure shows that the bacteria spores have been physically affected, as their size has gotten smaller and the appearance has changed.

Hintze, Paul E.↗

Evaluation of Low-Pressure Cold Plasma for Disinfection of ISS Grown Produce and Metallic Instrumentation

Cold plasma (CP) cleaning is a dry, non-thermal process, which can provide broad-spectrum antimicrobial activity yet reportedly causes little to no damage to the object being sanitized. Since cold plasma uses no liquids, it has the distinct advantage when used in microgravity of not having to separate liquids from the item being cleaned. This paper will present results on an effort to use low pressure CP to disinfect or sterilize materials for in space applications. Exposure times from 0 to 60 minutes and pressures ranging from 0.10 to 1.0 mbar were used to optimize plasma parameters. Tests were done on produce and metal coupons to simulate medical equipment. Escherichia coli was used as the challenge organism on produce and Bacillus pumilus SAFR-32 was used on metal surfaces. Produce testing was not successful, with unacceptable kill rates and the produce being negatively impacted by exposure to the plasma. The plasma caused a 5 log reduction in the number of viable bacteria on metal coupon tests, which placed the number of viable bacteria below the detection limit. This is a very promising result showing that sterilization of medical equipment with cold plasma is feasible. Scanning Electron Microscope images were taken before and after exposure. The images after plasma exposure show that the bacteria spores have been physically affected, as their size has gotten smaller and their appearance has changed.

Hintze, Paul E.↗

Hydrogen-oxygen catalytic ignition and thruster investigation. Volume 1: Catalytic ignition and low pressure thruster evaluations

An experimental and analytical program was conducted to evaluate catalytic igniter operational limits, igniter scaling criteria, and delivered performance of cooled, flightweight gaseous hydrogen-oxygen reaction control thrusters. Specific goals were to: (1) establish operating life and environmental effects for both Shell 405-ABSG and Engelhard MFSA catalysts, (2) provide generalized igniter design guidelines for high response without flashback, and (3) to determine overall performance of thrusters at chamber pressures of 15 and 300 psia (103 and 2068 kN/sq m) and thrust levels of 30 and 1500 lbf, respectively. The experimental results have demonstrated the feasibility of reliable, high response catalytic ignition and the effectiveness of ducted chamber cooling for a high performance flightweight thruster. This volume presents the results of the catalytic igniter and low pressure thruster evaluations are presented.

Johnson, R. J.↗

Scale-Resolving Simulations of Low-Pressure Turbine Cascades with Wall Roughness Using A Spectral-Element Method

The accurate prediction of wall-roughness effects in turbomachinery is becoming critical as turbine designers address airfoil surface quality and degradation concerns arising from the shift to advanced ceramic matrix composite (CMC) or additively-manufactured airfoils operating in higher temperature environments. In this paper, a recently developed computational capability for accurate and efficient scale-resolving simulations of turbomachinery is extended to analyze the boundary- layer separation and transition characteristics in a rough-wall low-pressure turbine (LPT) cascade. The computational capability is based on an entropy-stable discontinuous-Galerkin spectral-element approach that extends to arbitrarily high orders of spatial and temporal accuracy, and is implemented in an efficient manner for a modern high performance computer architecture. Results from the scale-resolving simulations of both smooth and rough airfoil cascades are presented and compared to previous experiments and numerical simulations. The results show that the suction surface boundary layer undergoes laminar separation, transition, and turbulent reattachment for the smooth airfoil cascade, while in the presence of roughness the separation and transition behavior of the suction surface boundary layer is substantially modified. The differences between the smooth and rough airfoil cascades are then highlighted by a detailed analysis of their respective turbulent flow fields.

Spectral-Element↗

An aircraft instrument design for in situ tropospheric OH measurements by laser induced fluorescence at low pressures

The hydroxyl radical (OH) is important for many processes involved in tropospheric chemistry. For instance, it initiates the photochemical degradation of gases that cause global climate change, such as methane and the chlorofluorocarbon substitutes (HCFCs). Because of its reactivity, its abundances are less than 0.1 pptv. Thus, OH has been very difficult to measure accurately, despite its importance. Techniques have evolved, however, so that good measurements of tropospheric OH abundances are now possible. One of these techniques that is adaptable to aircraft measurements is the laser induced fluorescence detection of the OH radical in a detection chamber at low pressures. The current ground-based instrument, which can be readily adapted to aircraft, can detect OH abundances of 1.4 x 10 exp 5 OH molecules/cu cm with S/N = 2 in 30 sec, and 5 x 10 exp 4/cu cm in 5 min.

Brune, William H.↗

An Experimental Study on Low Pressure Frost Formation for Lunar Polar Water Capture

In-situ resource utilization (ISRU) is a vital component of NASA’s mission to the Moon and beyond, as the extraction of resources from the environment can reduce payload weight and the frequency of resupply missions. Since the discovery of water in the regolith of the permanently shadowed regions (PSR) of the Moon, its extraction and transport has become an area of increasing interest for NASA. One proposed method is heating icy regolith to free the water before desublimating and transporting it as ice in a tanker. However, little is known regarding the dynamics of frost growth at low pressures, and an understanding of the heat transfer process is required to properly size the heat exchanger for the tanker. To investigate this phenomenon, a cold plate was placed in a vacuum chamber with water vapor directed at its surface. The chamber pressure (300 and 500 Pa) and cold plate temperature (–18 to –5 °C) were kept below the triple point and varied throughout the experiment to examine their impact on frost layer heat transfer. As water flowed into the chamber and deposited on the cold plate surface, the heat flux and temperature were measured along with the frost layer thickness and/or mass. Density calculated at the conclusion of each test suggests the frost layer is denser than that of frost grown at atmospheric pressure. The results demonstrate unexpected density and heat transfer characteristics and require development of a new model of frost growth for lunar conditions.

In situ Resource Utiliztion↗

An Experimental Study on Low Pressure Frost Formation for Lunar Polar Water Capture

In-situ resource utilization (ISRU) is a vital component of NASA’s mission to the Moon and beyond, as the extraction of resources from the environment can reduce payload weight and the frequency of resupply missions. Since the discovery of water in the regolith of the permanently shadowed regions (PSR) of the Moon, its extraction and transport has become an area of increasing interest for NASA. One proposed method is heating icy regolith to free the water before de-sublimating and transporting it as ice in a tanker. However, little is known regarding the dynamics of frost growth at low pressures, and an understanding of the heat transfer process is required to properly size the heat exchanger for the tanker. To investigate this phenomenon, a cold plate was placed in a vacuum chamber with water vapor directed at its surface. The chamber pressure (300 and 500 Pa) and cold plate temperature (–18 to –5 °C) were kept below the triple point and varied throughout the experiment to examine their impact on frost layer heat transfer. As water flowed into the chamber and deposited on the cold plate surface, the heat flux and temperature were measured along with the frost layer thickness and/or mass. Density calculated at the conclusion of each test suggests the frost layer is denser than that of frost grown at atmospheric pressure. The results demonstrate unexpected density and heat transfer characteristics and require development of a new model of frost growth for lunar conditions

Lunar polar↗

DNS of Low-Pressure Turbine Cascade Flows with Elevated Inflow Turbulence Using a Discontinuous-Galerkin Spectral-Element Method

Recent progress towards developing a new computational capability for accurate and efficient high-fidelity direct numerical simulation (DNS) and large-eddy simulation (LES) of turbomachinery is described. This capability is based on an entropy- stable Discontinuous-Galerkin spectral-element approach that extends to arbitrarily high orders of spatial and temporal accuracy, and is implemented in a computationally efficient manner on a modern high performance computer architecture. An inflow turbulence generation procedure based on a linear forcing approach has been incorporated in this framework and DNS conducted to study the effect of inflow turbulence on the suction- side separation bubble in low-pressure turbine (LPT) cascades. The T106 series of airfoil cascades in both lightly (T106A) and highly loaded (T106C) configurations at exit isentropic Reynolds numbers of 60,000 and 80,000, respectively, are considered. The numerical simulations are performed using 8th-order accurate spatial and 4th-order accurate temporal discretization. The changes in separation bubble topology due to elevated inflow turbulence is captured by the present method and the physical mechanisms leading to the changes are explained. The present results are in good agreement with prior numerical simulations but some expected discrepancies with the experimental data for the T106C case are noted and discussed.

Garai, Anirban↗

Heat transfer and visual observation of pool boiling of next-generation low-pressure refrigerant: R1336mzz(Z)

R1336mzz(Z) is a non-flammable and non-toxic hydrofluoroolefin (HFO), which is a potential alternative working fluid for multiple applications such as centrifugal chillers, industrial high temperature heat pumps, and Organic Rankine Cycles. Pool boiling is one of the primary heat transfer modes in shell-and-tube evaporators, and there is limited data for R1336mzz(Z) due to its recent introduction. This study investigated the pool boiling characteristics of R1336mzz(Z) using a closed-loop apparatus. Heat transfer coefficients on a smooth aluminum surface were measured at various heat fluxes with a heating block, and the results were compared to predictions from various correlations. Additionally, a high-speed camera was employed to visualize and analyze the pool boiling behavior of this next-generation low-pressure refrigerant.

Yang, Cheng-Min [ORNL]↗

Low Pressure Plasma Sprayed Overlay Coatings for GRCop-84 Combustion Chamber Liners for Reusable Launch Vehicles

An advanced Cu-8(at.%)Cr-4%Nb alloy developed at NASA's Glenn Research Center, and designated as GRCop-84, is currently being considered for use as combustor chamber liners and nozzle ramps in NASA s future generations of reusable launch vehicles (RLVs). However, past experience has shown that unprotected copper alloys undergo an environmental attack called "blanching" in rocket engines using liquid hydrogen as fuel and liquid oxygen as the oxidizer. Potential for sulfidation attack of the liners in hydrocarbon-fueled engines is also of concern. Protective overlay coatings alloys are being developed for GRCop-84. The development of this coatings technology has involved a combination of modeling, coatings development and characterization, and process optimization. Coatings have been low pressure plasma sprayed on GRCop-84 substrates of various geometries and shapes. Microstructural, mechanical property data and thermophysical results on the coated substrates are presented and discussed.

Raj, S. V.↗

Exploring the Utilization of Low-Pressure, Piston-Cylinder Experiments to Determine the Bulk Compositions of Finite, Precious Materials

Determining the bulk composition of precious materials with a finite mass (e.g., meteorite samples) is extremely important in the fields of Earth and Planetary Science. From meteorite studies we are able to place constraints on large scale planetary processes like global differentiation and subsequent volcanism, as well as smaller scale processes like crystallization in a magma chamber or sedimentary compaction at the surface. However, with meteorite samples in particular, far too often we are limited by how precious the sample is as well as its limited mass. In this study, we have utilized aliquots of samples previously studied for toxicological hazards, including both the fresh samples (lunar mare basalt NWA 4734, lunar regolith breccia NWA 7611, martian basalt Tissint, martian regolith breccia NWA 7034, a vestian basalt Berthoud, a vestian regolith breccia NWA 2060, and a terrestrial mid-ocean ridge basalt (MORB)), and those that underwent iron leaching (Tissint, NWA 7034, NWA 4734, MORB). With these small masses of material, we performed low pressure (approx. 0.75 GPa), high temperature (greater than 1600 degrees Celsius) melting experiments. Each sample was analyzed using a JEOL 8530F electron microprobe to determine the bulk composition of the materials that were previously examined. When available, the results of our microprobe data were compared with bulk rock compositions in the literature. The results of this study show that with this technique, only approx. 50 mg of sample is required to accurately determine the bulk composition of the materials of interest.

Vander Kaaden, K. E.↗

In situ detection of tropospheric OH and HO2 by laser-induced fluorescence in a detection chamber at low pressure

Just as in the method of Hard and O'Brien, ambient air is pulled through an approximately 1 mm diameter inlet into a detection chamber that is maintained at a pressure of 2.4 torr. The ambient air stream travels through the detection chamber with a velocity of greater than 100 m sec(exp -1) in a narrow stream, constrained by the addition of an inert gas flow (0.4 torr). The OH molecule is both excited and detected in the A(exp 2)Sigma (v' = 0) yields X(exp 2)II (v'' = 0) transition at 308 nm. Light from a copper vapor-pumped dye laser (rep. rate = 10kHz; pulse length = 20 ns; linewidth = .1 cm(exp -1), and average power = 15 mW), resonant with the Q(sub 1)(3) transition, is multipassed through a White cell and intercepts the air stream as 24 non-overlapping 2mm by 5mm beams. A fast microchannel plate detector is turned off during the laser pulse to prevent saturation of the detector due to Rayleigh and chamber scattering. It is turned on 30-100 nsec after the end of the laser pulse for 300 ns to collect resonance fluorescence from OH. HO2 is detected by chemical conversion to OH by reaction with reagent NO, followed by OH detection. Both the detection sensitivity and the inlet characteristics must be understood for any in situ instrument. For the calibration of the detection sensitivity, OH is produced quantitatively by the fast H + NO2 yields OH + NO reaction in a low pressure, flowing discharge tube connected to the detection chamber. The inlet transmission of OH inlet is calibrated separately.

Brune, William H.↗

Low fractional volume superconductivity in single crystals of Pr{sub 4}Ni{sub 3}O{sub 10} under pressure

Magnetotransport measurements of P⁢r4⁢N⁢i3⁢O10 single crystals performed under externally applied pressures up to 73 GPa in diamond anvil cells with either KBr or Nujol oil as pressure media yield signatures of superconductivity with a maximum onset temperature of approximately 31 K. True zero resistance was not observed, consistent with a nonpercolating superconducting volume fraction. Magnetization measurements provided corroborating evidence of superconductivity, with a pressure-dependent diamagnetic signal occurring below the onset temperature, and an estimate from the absolute value of the susceptibility suggests a superconducting volume fraction on the order of 10%. We observe sample to sample variations in the magnitude and pressure dependence of 𝑇𝑐 as well as a dependence on the configuration of electrical contacts on a given sample. Possible causes of this behavior may be significant inhomogeneities in the pressure and/or damage to the samples induced by the pressure media as well as inhomogeneities in the crystals themselves. The results imply that our as-grown P⁢r4⁢N⁢i3⁢O10 single crystals are not bulk superconductors but that there is a minority structure present within the crystals that is indeed superconductin

Chen, Xinglong↗

Magnetically coupled loading chamber and apparatus for in situ MAS NMR: operating under either high or low pressure

A sample chamber holder for MAS-NMR capable of operating at both low and high pressures. In one example the sample chamber holder is made up of a sample holder body defining a sample chamber therein, a connector configured to operatively statically hold an in situ rotor within the sample chamber; a coupler configured to operatively connect the sampler holder body to a magnetically coupled rotation member. The magnetically coupled rotation member is configured to engage and rotate a sealing cap from an NMR rotor in such a way so as to allow an NMR cap to be alternatively opened or sealed in-situ while the NMR rotor remains statically positioned in an NMR device.

Hu, Jian Z.↗