Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “loading”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Numerical Analysis of Fatigue Behavior of ITER-Like Monoblock Divertor Interlayer Under Coupled Heat Loads

High-confinement mode is a very prominent operation style for future fusion device due to its unique advantages. However, the conjuncted edge localized modes (ELMs) are very difficult to control so that divertor plates are very prone to suffer both stationary high heat flux (HHF) loads of long-pulse operating mode and transient shock loads of ELMs. Most previous researches focus on degradation of plasma facing material (PFM), however, as a layer joining PFM and cooling tube, the soft copper interlayer suffers concentrated thermal stress loads due to mismatched thermal expansion of PFM and cooling tube. Its thermal fatigue behavior under such coupled loads is also of great significance to structural safety of divertor component. With such a motivation, the reduction effects on fatigue life time of a typical interlayer of monoblock divertor under series of coupled HHF and ELMs shock loading conditions are investigated. It is found that: (1) The transient shock feature of ELMs loading is propagated into interlayer with less sharp pattern. The increase of damage induced by coupled ELMs loading is limited in single cycle, while the accumulated damage of multiple consecutive coupled loading cycles is increased nonlinearly. (2) Under the coupled HHF and ELMs loading, the fatigue life time of interlayer is generally decreasing. The magnitude of decrease is increasing nonlinearly with the magnitude of ELMs peak and averaged heat flux. (3) For three characteristic parameters of ELMs shock loading such as frequency, duration and peak heat flux, the peak heat flux and frequency are two parameters more sensitive to determine coupled reduction effects on fatigue lifetime of the interlayer, while for high frequency case, time averaged heat flux takes the lead.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A novel stochastic modeling method to simulate cooling loads in residential districts

District cooling systems are widely used in urban residential communities in China. Most of such systems are oversized, which leads to wasted investment, low operational efficiency and, thus, waste of energy. The accurate prediction of district cooling loads that can support the rightsizing of cooling plant equipment remains a challenge. This study develops a novel stochastic modeling method that consists of (1) six prototype house models representing most apartments in a district, (2) occupant behavior models of residential buildings reflecting their spatial and temporal diversity as well as their complexity based on a large-scale residential survey in China, and (3) a stochastic sampling process to represent all apartments and occupants in the district. The stochastic method was applied to a case study using the Designer's Simulation Toolkit (DeST) to simulate the cooling loads of a residential district in Wuhan, China. The simulation results agreed well with the measured data based on five performance metrics representing the aggregated cooling consumption, the peak cooling loads, the spatial load distribution, the temporal load distribution and the load profiles. Two prevalent simulation methods were also employed to simulate the district cooling loads. Here, the results showed that oversimplified assumptions about occupant behavior could lead to significant overestimation of the peak cooling load and the total cooling loads in the district. Future work will aim to simplify the workflow and data requirements of the stochastic method for its application, and to explore its use in predicting district heating loads and in commercial or mixed-use districts.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Real-time visualization of dynamic fractures in porcine bones and the loading-rate effect on their fracture toughness

In this work we visualized, in real time, the dynamic fracture behaviors in porcine cortical bone from humerus and porcine trabecular bone from nasal bone at a high loading rate using highspeed synchrotron X-ray phase-contrast imaging (PCI). Dynamic three-point bending loading was applied on notched bone specimens by a modified Kolsky compression bar and images of the entire fracture events were recorded with an ultra-high-speed camera. Experiments at a quasi-static loading rate on material testing system (MTS) were also performed to identify the loading-rate effects on the fracture toughness of the two types of bone. Three-dimensional synchrotron X-ray computed tomography was conducted to examine the initial microstructures in the bone specimens before mechanical loading. At the dynamic loading rate, the onset locations of crack initiation were found to be independent from the bone types. The deleterious effect of dynamic loading rate on bone's fracture toughness was verified in this study and the crack was found to propagate at higher speeds in cortical bone than in trabecular bone. In a comparison of the observed more torturous crack paths at the quasi-static loading rate, cracks in dynamically loaded bone specimens generally followed the paths with less in-plane deflections and out-of-plane twists. However, our experimental results also indicated that, although the extent was diminished at dynamic loading rate, the crack deflections at osteon cement lines still played a role as a major toughening mechanism to dynamic fractures in transversely orientated cortical bone.

60 APPLIED LIFE SCIENCES↗

Influence on Structural Loading of a Wave Energy Converter by Controlling Variable-Geometry Components and the Power Take-Off

Oceans are harsh environments and can impose significant loads on deployed structures. The deployment of wave energy converters (WECs) faces a design challenge with apparently contradictory goals. A WEC should be designed to maximize the energy absorbed while ensuring the operating wave condition does not exceed the failure limits of the device itself. Therefore, the loads endured by the support structure are a design constraint for the system. Adaptability to different sea states is, therefore, highly desirable. This work uses a WEC-Sim model of a variable-geometry oscillating wave energy converter (VGOSWEC) mounted on a support structure simulated under different wave scenarios. A VGOSWEC resembles a paddle pitching about a fixed hinge perpendicular to the incoming wave fronts. Therefore, the hinge experiences loads perpendicular to its axis as it maintains its position. The geometry of the VGOSWEC is varied by opening a series of controllable flaps on the pitching paddle when the structure experiences threshold loads. Because opening the flaps lets the waves transmit through the paddle, it is hypothesized that opening the flaps should result in load shedding at the base of the support structure. The load shedding is achieved by reducing the moments about the hinge axis. This work compares the hydrodynamic coefficients, natural periods, and response amplitude operators from completely closed to completely open configurations of the controllable flaps. The comparisons quantify the effects of letting the waves transmit through the VGOSWEC. This work shows that the completely open configuration can reduce the pitch and surge loads on the base of the support structure by as much as 80%. It was observed that at the paddle's resonance frequency, the loads on the structure increased substantially. This increase in loads can be mitigated by a rotational power take-off damping about the hinge axis. Changing the rotational power take-off damping was identified as an additional design parameter that can be used to control the loads experienced by the WEC's support structure.

fixed and floating structures↗

High power s-band vacuum load

Through a combination of experimentation and calculation the components of a novel room temperature dry load were successfully fabricated. These components included lossy ceramic cylinders of various lengths, thicknesses, and percent of silicon carbide (SiC). The cylinders were then assembled into stainless steel compression rings by differential heating of the parts and a special fixture. Post machining of this assembly provided a means for a final weld. The ring assemblies were then measured for S-parameters, individually and in pairs using a low-cost TE10 rectangular to TE01 circular waveguide adapter specially designed to be part of the final load assembly. Matched pairs of rings were measured for assembly into the final load, and a sliding short designed and fabricated to assist in determining the desired short location in the final assembly. The plan for the project was for Muons, Inc. to produce prototype loads for long-term testing at SLAC. The STTR funds for SLAC were to upgrade and operate their test station to ensure that the loads would satisfy their requirements. Phase III was to be the sale to SLAC of loads that Muons, Inc. would manufacture. However, an alternate solution that involved a rebuild of the old loads, reduced SLAC budget projections, and a relaxed time for the replacement of all loads meant that in-house labor will be used to do the upgrade without the need for the loads developed in this project. Consequently, the project was terminated before the long term testing was initiated. However, SLAC can use the upgraded test stand to compare the long-term performance of the ones produced in this project with their rebuilt loads when they are available.

42 ENGINEERING↗

Characterizing Plug Load Energy Use and Savings Potential in Army Buildings

The Assistant Secretary of the Army (Installations, Energy and Environment) tasked the Pacific Northwest National Laboratory to examine plug loads in typical Army buildings. Plug loads (also known as miscellaneous electric loads (MELs)) represent the electricity used by appliances and devices that are plugged in or hardwired and serve functions outside of a building’s core end uses. Common plug loads include computers, printers, copiers, networking devices, refrigerators, and vending machines. They also include personal electronic devices such as televisions, smart phones, tablets, and gaming systems. Examples of hardwired MELs include elevators, air compressors, and fire and security systems. The findings from this study confirm that significant energy is consumed within Army buildings by plug load devices and hardwired MEL equipment. A number of opportunities are identified for reducing unnecessary energy use that could save the Army over $5 million per year when broadly applied. Army regulations clearly spell out expectations for the purchase and operation of information technology equipment (computers, laptops, monitors, printers, and multi-function devices). However, the policies regarding the shutdown or activation of sleep and other lower power modes after 30 minutes of inactivity (15 minutes for monitors) do not appear to be consistently followed. There are many effective approaches and pathways for impacting change as it relates to improving awareness, implementing measures, and adjusting behaviors to identify and reduce plug load energy use. The Army should prioritize and consider deploying all of these to better understand and manage plug load equipment to save energy and enhance resilience across their facilities. Engaging the building occupants who use these devices daily via outreach and education should be a strong component of the strategy. The focus should be on reducing waste without sacrificing productivity or the benefits that many of these devices provide. Continued evaluation of plug loads beyond that performed here is important to gather lessons from additional building and equipment types, and to stay aware of evolving device technology and management options. This will highlight additional needs for policies, best practices, control technologies, and education of personnel to achieve real reductions in energy waste from plug load equipment. It is recommended that this study may serve as the foundation for a broader and sustained focus on plug loads and MELs, towards simultaneously enhancing the productivity, readiness, and resilience of the Army while reducing energy use and demand, and freeing up resources to better support the mission.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Limits on the Range and Rate of Change in Power Take-Off Load in Ocean Wave Energy Conversion: A Study Using Model Predictive Control

Previous work comparing power take-off (PTO) architectures for ocean wave-powered reverse osmosis suggests that variable displacement in the wave energy converter (WEC)-driven pump does not offer a significant performance advantage. A limitation of that study is that the WEC was subject to a constant load within a given sea state (“Coulomb damping”) and did not account for controlled, moment-to-moment variation of the PTO load enabled by a variable displacement pump. This study explores the potential performance advantage of a variable PTO load over Coulomb damping. Model predictive control is used to provide optimal load control with constraints on the PTO load. The constraints include minimum and maximum loads and a limit on the rate of load adjustment. Parameter studies on these constraints enable conclusions about PTO design requirements in addition to providing an estimated performance advantage over Coulomb damping. Numerical simulation of the Oyster 1 WEC is carried out with performance weighted by historical sea state data from Humboldt Bay, CA. The results show a performance advantage of up to 20% higher yearly-average power absorption over Coulomb damping. Additionally, the parameter studies suggest that the PTO load should be adjustable down to at least 25% of the maximum load and should be adjustable between the minimum and maximum loads within a few seconds.

16 TIDAL AND WAVE POWER↗

A Wave Energy Converter Design Load Case Study

This article presents an example by which design loads for a wave energy converter (WEC) might be estimated through the various stages of the WEC design process. Unlike previous studies, this study considers structural loads, for which, an accurate assessment is crucial to the optimization and survival of a WEC. Three levels of computational fidelity are considered. The first set of design load approximations are made using a potential flow frequency-domain boundary-element method with generalized body modes. The second set of design load approximations are made using a modified version of the linear-based time-domain code WEC-Sim. The final set of design load simulations are realized using computational fluid dynamics coupled with finite element analysis to evaluate the WEC’s loads in response to both regular and focused waves. This study demonstrates an efficient framework for evaluating loads through each of the design stages. In comparison with experimental and high-fidelity simulation results, the linear-based methods can roughly approximate the design loads and the sea states at which they occur. The high-fidelity simulations for regular wave responses correspond well with experimental data and appear to provide reliable design load data. The high-fidelity simulations of focused waves, however, result in highly nonlinear interactions that are not predicted by the linear-based most-likely extreme response design load method.

16 TIDAL AND WAVE POWER↗

Sensitivity analysis of the effect of wind and wake characteristics on wind turbine loads in a small wind farm

Abstract. Wind turbines are designed using a set of simulations to determine the fatigue and ultimate loads, which are typically focused solely on unwaked wind turbine operation. These structural loads can be significantly influenced by the wind inflow conditions. Turbines experience altered inflow conditions when placed in the wake of upstream turbines, which can additionally influence the fatigue and ultimate loads. It is important to understand the impact of uncertainty on the resulting loads of both unwaked and waked turbines. The goal of this work is to assess which wind-inflow-related and wake-related parameters have the greatest influence on fatigue and ultimate loads during normal operation for turbines in a three-turbine wind farm. Twenty-eight wind inflow and wake parameters are screened using an elementary effects sensitivity analysis approach to identify the parameters that lead to the largest variation in the fatigue and ultimate loads of each turbine. This study uses the National Renewable Energy Laboratory (NREL) 5 MW baseline wind turbine, simulated with OpenFAST and synthetically generated inflow based on the International Electrotechnical Commission (IEC) Kaimal turbulence spectrum with the IEC exponential coherence model using the NREL tool TurbSim. The focus is on sensitivity to individual parameters, though interactions between parameters are considered, and how sensitivity differs between waked and unwaked turbines. The results of this work show that for both waked and unwaked turbines, ambient turbulence in the primary wind direction and shear are the most sensitive parameters for turbine fatigue and ultimate loads. Secondary parameters of importance for all turbines are identified as yaw misalignment, streamwise integral length, and the exponent and streamwise components of the IEC coherence model. The tertiary parameters of importance differ between waked and unwaked turbines. Tertiary effects account for up to 9.0 % of the significant events for waked turbine ultimate loads and include veer, non-streamwise components of the IEC coherence model, Reynolds stresses, wind direction, air density, and several wake calibration parameters. For fatigue loads, tertiary effects account for up to 5.4 % of the significant events and include vertical turbulence standard deviation, lateral and vertical wind integral lengths, non-streamwise components of the IEC coherence model, Reynolds stresses, wind direction, and all wake calibration parameters. This information shows the increased importance of non-streamwise wind components and wake parameters in the fatigue and ultimate load sensitivity of downstream turbines.

17 WIND ENERGY↗

Short-Term Load Forecasting-Based Automatic Distribution Network Reconfiguration

In a traditional dynamic network reconfiguration study, the optimal topology is determined at every scheduled time point by using the real load data measured at that time. The development of the load forecasting technique can provide an accurate prediction of the load power that will happen in a future time and provide more information about load changes. With the inclusion of load forecasting, the optimal topology can be determined based on the predicted load conditions during a longer time period instead of using a snapshot of the load at the time when the reconfiguration happens; thus, the distribution system operator can use this information to better operate the system reconfiguration and achieve optimal solutions. This paper proposes a short-term load forecasting approach to automatically reconfigure distribution systems in a dynamic and pre-event manner. Specifically, a short-term and high-resolution distribution system load forecasting approach is proposed with a forecaster based on support vector regression and parallel parameters optimization. The network reconfiguration problem is solved by using the forecasted load continuously to determine the optimal network topology with the minimum amount of loss at the future time. The simulation results validate and evaluate the proposed approach.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Influence on Structural Loading of a Wave Energy Converter by Controlling Variable-Geometry Components and the Power Take-Off: Preprint

Oceans are a harsh environment and can impose significant loads on deployed structures. Deployment of wave energy converters (WECs) faces a design challenge with apparently contradictory goals. A WEC should be designed to maximize the energy absorbed while ensuring the operating wave condition does not exceed the failure limits of the device itself. Therefore, the loads endured by the support structure are a design constraint for the system. Adaptability to different sea states is, therefore, highly desirable. This work uses a WEC-Sim model of a Variable Geometry Oscillating Wave Energy Converter (VGOSWEC) mounted on a support structure simulated under different wave scenarios. A VGOSWEC resembles a paddle pitching about a fixed hinge perpendicular to the incoming waves-fronts. Therefore, the hinge experiences loads perpendicular to its axis as it maintains its position. The geometry of the VGOSWEC was varied by opening a series of controllable flaps on the pitching paddle when the structure experiences threshold loads. Since opening the flaps lets the waves transmit through the paddle, it is hypothesized that opening the flaps should result in load shedding at the base of the support structure. This load shedding is achieved by reducing the moments about the hinge axis. This work compares the hydrodynamic coefficients, natural periods, and Response Amplitude Operators (RAOs) from completely closed to completely open configurations of the controllable flaps. These comparisons quantify the effects of letting the waves transmit through the VGOSWEC. This work shows that the completely open configuration can reduce the pitch and surge loads on the base of the support structure by as much as 80%. It was observed that at the paddle's resonance frequency, the loads on the structure increased substantially. This increase in loads can be mitigated by a rotational Power Take-off (PTO) damping about the hinge axis. Changing the rotational PTO damping was identified as an additional design parameter that can be used to control the loads experienced by the WEC's support structure.

fixed and floating structures↗

Device-level plug load disaggregation in a zero energy office building and opportunities for energy savings

Along with heating, cooling, ventilation, and lighting, plug loads are one of the principal consumers of energy in commercial buildings. Managing ever-changing plug loads is a great challenge given the quantity and variety of devices in commercial buildings and the cost of monitoring equipment. To address this issue, we propose a method for developing a disaggregated model of an office building's plug loads that utilizes power data from a small portion of monitored devices and a device inventory. Using data from metering and control devices in the Research Support Facility at the National Renewable Energy Laboratory, we compared our model to the building's plug load submeters. We found that the model was effective in predicting the shape of the building's average plug loads; however, it did not account for the entire magnitude of the load. With the disaggregated breakdown, we identified devices that contributed significantly to the building's unoccupied load, such as the audio visual equipment as well as devices that contributed significantly at specific times of the day, such as the microwaves at noon. This disaggregated information enables building owners to make more informed decisions with respect to plug load controls and energy efficiency upgrades. Furthermore, we highlight how the plug loads in the Research Support Facility have changed over time and offer recommendations for implementing this disaggregation method in other buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Comparative Prospective Study of Load Distribution Projection Among Patients with Vertebral Fractures Treated with Percutaneous Vertebroplasty and a Control Group of Healthy Volunteers

Purpose: Through a prospective comparison of patients with vertebral fractures and normal population, we illustrate effect of percutaneous vertebroplasty (PV) upon projection of load distribution changes. Methods: Vertebroplasty group (36 symptomatic patients with osteoporotic vertebral fractures) was evaluated on an electronic baropodometer registering projection of weight bearing areas on feet. Load distribution between right and left foot (including rear-front of the same foot) during standing and walking was recorded and compared before (group V1) and the day after (group V2) PV. Control group (30 healthy asymptomatic volunteers-no surgery record) were evaluated on the same baropodometer. Results: Mean value of load distribution difference between rear-front of the same foot was 9.45 ± 6.79 % (54.72–45.28 %) upon standing and 14.76 ± 7.09 % (57.38–42.62 %) upon walking in the control group. Respective load distribution values before PV were 16.52 ± 11.23 and 30.91 ± 19.26 % and after PV were 10.08 ± 6.26 and 14.25 ± 7.68 % upon standing and walking respectively. Mean value of load distribution variation between the two feet was 6.36 and 14.6 % before and 4.62 and 10.4 % after PV upon standing and walking respectively. Comparison of load distribution variation (group V1–V2, group V1-control group) is statistically significant. Comparison of load distribution variation (group V2-control group) is not statistically significant. Comparison of load distribution variation among the two feet is statistically significant during walking but not statistically significant during standing. Conclusions: There is a statistically significant difference when comparing load distribution variation prior vertebroplasty and that of normal population. After vertebroplasty, this difference normalizes in a statistically significant way. PV is efficient on equilibrium-load distribution improvement as well.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A cross-dimensional analysis of data-driven short-term load forecasting methods with large-scale smart meter data

Electricity load forecasting is essential to utility operation and power grid stability. A wide spectrum of data-driven methods, ranging from linear regression models to more recent deep learning models have been adopted to forecast electric load over the years. However, there still lacks a holistic evaluation of the applicability of conventional statistical and machine learning based algorithms with respect to different temporal and spatial scopes, computational requirements, and sensitivity of model-tuning. Enabled by a large-scale electricity load profile dataset of over 40,000 residential customers in a utility region, we conducted a cross-dimensional analysis of data-driven load forecasting methods. Three regression-based and seven deep learning algorithms with different model configurations were evaluated in terms of their overall and peak load prediction accuracy, and training burdens, across spatial aggregation levels ranging from the transformer, feeder, substation, to neighborhood. We found, first, the load forecasting accuracy is constrained by a predictability boundary, influenced by the forecasting horizon and spatial aggregation level. Specifically, RandomForest, XGBoost, TFT, TSMixer, and TiDE models achieved less than 10 % prediction error for up to 96-h ahead forecasting for district, substation, and feeder levels, while other models struggle at long-horizon predictions; Second, for winter and summer peak load dates, most models were able to predict the peak demand timing within ± 1 h, but the prediction percentage error varied by models, with TFT and TiDE models being the top performers; Third, models with similar prediction accuracy can differ in training burden by an order of magnitude. Therefore, choosing model configurations that balance prediction performance and computational resource is an important practical consideration for large-scale deployment of the machine learning based load forecasting. The outcome of this study can guide researchers and practitioners to choose the proper load forecasting algorithms based on their problem scope, required accuracy, and available resources. The predictability boundary can serve as a benchmark for electricity load forecasting problems with new algorithms and datasets.

Li, Han↗

Mechanical Response of Castlegate Sandstone under Hydrostatic Cyclic Loading

The stress history of rocks in the subsurface affects their mechanical and petrophysical properties. Rocks can often experience repeated cycles of loading and unloading due to fluid pressure fluctuations, which will lead to different mechanical behavior from static conditions. This is of importance for several geophysical and industrial applications, for example, wastewater injection and reservoir storage wells, which generate repeated stress perturbations. Laboratory experiments were conducted with Castlegate sandstone to observe the effects of different cyclic pressure loading conditions on a common reservoir analogue. Each sample was hydrostatically loaded in a triaxial cell to a low effective confining pressure, and either pore pressure or confining pressure was cycled at different rates over the course of a few weeks. Fluid permeability was measured during initial loading and periodically between stress cycles. Samples that undergo cyclic loading experience significantly more inelastic (nonrecoverable) strain compared to samples tested without cyclic hydrostatic loading. Permeability decreases rapidly for all tests during the first few days of testing, but the decrease and variability of permeability after this depend upon the loading conditions of each test. Cycling conditions do affect the mechanical behavior; the elastic moduli decrease with the increasing loading rate and stress cycling. The degree of volumetric strain induced by stress cycles is the major control on permeability change in the sandstones, with less compaction leading to more variation from measurement to measurement. The data indicate that cyclic loading degrades permeability and porosity more than static conditions over a similar period, but the petrophysical properties are dictated more by the hydrostatic loading rate rather than the total length of time stress cycling is imposed.

58 GEOSCIENCES↗

Load Forecasting in Electric Utility Integrated Resource Planning

Integrated resource planning (IRP) is a process used by many vertically-integrated U.S. electric utilities to determine least-cost/risk supply and demand-side resources that meet government policy objectives and future obligations to customers and, in many cases, shareholders. Forecasts of energy and peak demand are a critical component of the IRP process. There have been few, if any, quantitative studies of IRP long-run (planning horizons of two decades) load forecast performance and its relationship to resource planning and actual procurement decisions. In this paper, we evaluate load forecasting methods, assumptions, and outcomes for 12 Western U.S. utilities by examining and comparing plans filed in the early 2000s against recent plans, up to year 2014. We find a convergence in the methods and data sources used. We also find that forecasts in more recent IRPs generally took account of new information, but that there continued to be a systematic over-estimation of load growth rates during the period studied. We compare planned and procured resource expansion against customer load and year-to-year load growth rates, but do not find a direct relationship. Load sensitivities performed in resource plans do not appear to be related to later procurement strategies even in the presence of large forecast errors. These findings suggest that resource procurement decisions may be driven by other factors than customer load growth. Our results have important implications for the integrated resource planning process, namely that load forecast accuracy may not be as important for resource procurement as is generally believed, that load forecast sensitivities could be used to improve the procurement process, and that management of load uncertainty should be prioritized over more complex forecasting techniques.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Overcoming the Technical Challenges of Coordinating Distributed Load Resources at Scale (Final Report)

Significant recent research has investigated the potential for loads to provide balancing services to the grid. However, this research has not addressed key issues that may arise when such schemes are applied at scale including: 1. Distribution Network Issues. Coordination of large numbers of loads could result in power flows that violate distribution network constraints; 2. Stability Issues. Certain strategies to control loads can exhibit nonlinearity in the form of period-adding bifurcations and chaos. Other control strategies can potentially synchronize the behavior of large numbers of loads. In both cases, the outcome can be power oscillations and instability; 3. Communication Network Issues. Bidirectional low-latency communication channels between a central controller (or several distributed controllers) and each resource are expensive and likely not necessary for effective coordination. Our research questions were: What network, stability, and communication issues might arise in practice when we coordinate large aggregations of loads? How can we coordinate loads to achieve performance objectives in a cost effective manner while avoiding these issues? The ultimate technical goal of the project was the development of network-aware, communication-constrained, non-disruptive load control strategies with stability guarantees that achieve the performance requirements of typical balancing services at a sufficiently low cost to enable the load aggregator and customer to profit. The overall goal was to establish credibility for load control at scale and contribute to U.S. energy security and environmental goals. The team succeeded in answering these research questions and developing these control strategies. The overall approach was based on the development of three testing environments: a simulation testbed, an experimental testbed (20 physical model houses with window-box air conditioners) coupled with the simulation testbed, and a field testbed (100 actual homes in Austin, TX) coupled with the simulation testbed, which enabled controller testing, identification of issues, controller development, and controller validation. The resulting controller was used to demonstrate fast timescale grid balancing (frequency regulation) by aggregations of physical and virtual air conditioners, with sufficient quality to participate in the electricity market. Cost benefit analysis showed overall benefits to the participating households, load aggregators, and the grid, especially if the control technology was integrated directly into existing programmable communicating thermostats. The project provides a variety of wider benefits. Our technology transfer and outreach activities lead us to choose an open-source licensing commercialization pathway, enabling the project results to be available to researchers, industry, and the public. Furthermore, new grid balancing technologies will increase grid flexibility and will enable higher penetrations of intermittent renewable energy resources, such as wind and solar, to be connected to the grid, reducing its environmental impact, and mitigating climate change to the benefit of society.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Mechanical Loads on Spent Nuclear Fuel in the General 30 cm Package Drop Scenario

The U.S. Department of Energy Office of Nuclear Energy (DOE-NE) Spent Fuel and Waste Science & Technology (SFWST) research program is guided by the high-level goal of closing prioritized knowledge gaps related to spent nuclear fuel (SNF) storage and transportation, which are summarized by Saltzstein et al. (2020). One of the high-priority knowledge gaps is the identification and quantification of mechanical loads that are expected to affect SNF during normal conditions of transportation and storage to inform the range of physical SNF test programs. This report uses modeling and analysis methods to estimate the mechanical loads on spent nuclear fuel (SNF) in the general 30 cm package drop scenario. The drop scenario assumes impact limiters are in place in the transportation configuration and the impact surface is perfectly rigid. The goal of this analysis is to consider the universe of potential mechanical loading conditions that can happen to SNF and present the results in a manner that is useful for materials testing, decision making, and regulatory rule making purposes. This study uses validated finite element models and methods to perform a broad parametric study of key variables that can affect the mechanical loads on SNF during a hypothetical package free drop scenario. Physical drop test data from a cask and fuel assembly drop test campaign is the basis for model validation. Additionally, the results of the parametric study are used to inform a damage model, which uses multiple nonlinear regression to estimate the relationships between input variables and output response. The parametric finite element analyses consider thousands of input variable combinations, while the damage model estimates millions of combinations. The breadth of this study provides confidence that the potential range of mechanical loads that SNF might experience during the general 30 cm package drop scenario are characterized well enough to consider this knowledge gap closed. While this report documents the overall peak values calculated in this study, the 95 th percentile values, the histograms, and the observed trends are equally important. This study covered a large range of SNF temperatures, room temperature to 300°C, and burnups, 10 GWd/MTU to 62 GWd/MTU. Each temperature and burnup combination has a different cladding yield strain, so it is more meaningful to summarize the calculated cladding strain response as its factor of safety, which is defined relative to the yield strain. The factor of safety is calculated as the yield strain divided by the peak cladding strain. A factor of safety greater than unity indicates that the cladding remains below yield, whereas a value less than unity is indicative of plastic deformation. In all cases of this study a safety factor over 1.0 was calculated, although in the most limiting case at 300°C the safety factor was only 1.01, which suggests that yielding could occur when additional loads like rod internal pressure are included. When the temperature is restricted to 200°C the limiting safety factor increases to 1.28, which has significant margin to accommodate internal pressure and potential local cladding defects that could cause a local stress concentration. An important trend in the calculated fuel rod mechanical loads is that the 2 nd highest loaded fuel rod in an assembly tends to be significantly lower than the highest loaded rod. The implication is that even if one rod in an assembly experiences a failure the loads would have to be significantly higher to cause two or more rods to fail.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗