Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “light source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Rapid and efficient ambient temperature X-ray crystal structure determination at Turkish Light Source

High-resolution biomacromolecular structure determination is essential to better understand protein function and dynamics. Serial crystallography is an emerging structural biology technique which has fundamental limitations due to either sample volume requirements or immediate access to the competitive X-ray beamtime. Obtaining a high volume of well-diffracting, sufficient-size crystals while mitigating radiation damage remains a critical bottleneck of serial crystallography. As an alternative, we introduce the plate-reader module adapted for using a 72-well Terasaki plate for biomacromolecule structure determination at a convenience of a home X-ray source. We also present the first ambient temperature lysozyme structure determined at the Turkish light source (Turkish DeLight). The complete dataset was collected in 18.5 min with resolution extending to 2.39 Å and 100% completeness. Combined with our previous cryogenic structure (PDB ID: 7Y6A), the ambient temperature structure provides invaluable information about the structural dynamics of the lysozyme. Turkish DeLight provides robust and rapid ambient temperature biomacromolecular structure determination with limited radiation damage.

59 BASIC BIOLOGICAL SCIENCES↗

Inverse compton light source: a compact design proposal

In the last decade, there has been an increasing demand for a compact Inverse Compton Light Source (ICLS) which is capable of producing high-quality X-rays by colliding an electron beam and a high-quality laser. It is only in recent years when both SRF and laser technology have advanced enough that compact sources can approach the quality found at large installations such as the Advanced Photon Source at Argonne National Laboratory. Previously, X-ray sources were either high flux and brilliance at a large facility or many orders of magnitude lesser when produced by a bremsstrahlung source. A recent compact source was constructed by Lyncean Technologies using a storage ring to produce the electron beam used to scatter the incident laser beam. By instead using a linear accelerator system for the electron beam, a significant increase in X-ray beam quality is possible, though even subsequent designs also featuring a storage ring offer improvement. Preceding the linear accelerator with an SRF reentrant gun allows for an extremely small transverse emittance, increasing the brilliance of the resulting X-ray source. In order to achieve sufficiently small emittances, optimization was done regarding both the geometry of the gun and the initial electron bunch distribution produced off the cathode. Using double-spoke SRF cavities to comprise the linear accelerator allows for an electron beam of reasonable size to be focused at the interaction point, while preserving the low emittance that was generated by the gun. An aggressive final focusing section following the electron beam's exit from the accelerator produces the small spot size at the interaction point which results in an X-ray beam of high flux and brilliance. Taking all of these advancements together, a world class compact X-ray source has been designed. It is anticipated that this source would far outperform the conventional bremsstrahlung and many other compact ICLSs, while coming closer to performing at the levels found at large facilities than ever before. The design process, including the development between subsequent iterations, is presented here in detail, with the simulation results for this groundbreaking X-ray source.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dual-etalon cavity ring-down frequency-comb spectroscopy with broad band light source

In an embodiment, a dual-etalon cavity-ring-down frequency-comb spectrometer system is described. A broad band light source is split into two beams. One beam travels through a first etalon and a sample under test, while the other beam travels through a second etalon, and the two beams are recombined onto a single detector. If the free spectral ranges ("FSR") of the two etalons are not identical, the interference pattern at the detector will consist of a series of beat frequencies. By monitoring these beat frequencies, optical frequencies where light is absorbed may be determined.

47 OTHER INSTRUMENTATION↗

VerSoX B07-B: a high-throughput XPS and ambient pressure NEXAFS beamline at Diamond Light Source

The beamline optics and endstations at branch B of the Versatile Soft X-ray (VerSoX) beamline B07 at Diamond Light Source are described. B07-B provides medium-flux X-rays in the range 45-2200 eV from a bending magnet source, giving access to local electronic structure for atoms of all elements from Li to Y. It has an endstation for high-throughput X-ray photoelectron spectroscopy (XPS) and near-edge X-ray absorption fine-structure (NEXAFS) measurements under ultrahigh-vacuum (UHV) conditions. B07-B has a second endstation dedicated to NEXAFS at pressures from UHV to ambient pressure (1 atm). The combination of these endstations permits studies of a wide range of interfaces and materials. The beamline and endstation designs are discussed in detail, as well as their performance and the commissioning process.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Meeting Report: User Workshop on High-Power Lasers at the Linac Coherent Light Source

A two-day international workshop on the physics and integration of high-power lasers with the Linac Coherent Light Source was held in Stanford, USA, on October 1-2, 2013. The workshop was co-organized by UC Berkeley, Lawrence Berkeley, Lawrence Livermore and SLAC National Accelerator Laboratories. More than 150 scientists, including 30 students and postdocs who are working in high-intensity laser-matter interactions, fusion research, and dynamic high-pressure science came together from North America, Europe and Asia. The group discussed the most promising and important new physics experiments that will be enabled by the unique combination of high-power lasers with the world-class LCLS freeelectron laser X-ray beam.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Investigation of Beam Instability Under the Effects of Long-Range Transverse Wake Fields in the Berkeley Future Light Source

An ultra-relativistic charged particle bunch moving through a resonator cavity leaves behind a wake field that will affect subsequent bunches (if the bunch is not ultra-relativistic, the wake field will not be exclusively behind it). If the initial bunch enters the cavity off-axis, it will produce a transverse wake field that can then kick later bunches off the axis. Thus, even bunches that were initially traveling on axis could be displaced and, in turn, produce their own transverse wake fields, affecting following bunches. The offsets obtained by bunches could increase along the bunch train, leading to the so-called multi-bunch beam break-up instability [1]. The purpose of our investigation is to see whether such instability will occur in the superconducting, 1.3 GHz, 2.5GeV linac (see Table 1) planned for the Berkeley future light source (BFLS). We assume an initial steady-state situation established for machine operation; i.e. a continuous process where every bunch follows the same trajectory through the linac, with only small deviations from the axis of the rf structures. We will look at a possible instability arising from a bunch having a small deviation from the established trajectory. Such a deviation would produce a wake field that is slightly different from the one produced by the bunches following the established trajectory. This could lead to subsequent bunches deviating further from the established trajectory. We will assume the deviations are small (at first) and so the difference in the wake field caused by a bunch not traveling along the established trajectory is well approximated by a long-range transverse dipole wake. We are concerned only with deviations from the established trajectory; thus, in our models, a transverse position of zero corresponds to the bunch traveling along the established trajectory. Under this assumption, only the additional long-range transverse dipole wake remains in our models.

43 PARTICLE ACCELERATORS↗

Science and Technology of Future Light Sources

Many of the important challenges facing humanity, including developing alternative sources of energy and improving health, are being addressed by advances that demand the improved understanding and control of matter. While the visualization, exploration, and manipulation of macroscopic matter have long been technological goals, scientific developments in the twentieth century have focused attention on understanding matter on the atomic scale through the underlying framework of quantum mechanics. Of special interest is matter that consists of natural or artificial nanoscale building blocks defined either by atomic structural arrangements or by electron or spin formations created by collective correlation effects The essence of the challenge to the scientific community has been expressed in five grand challenges for directing matter and energy recently formulated by the Basic Energy Sciences Advisory Committee. These challenges focus on increasing our understanding of, and ultimately control of, matter at the level of atoms, electrons. and spins, as illustrated in Figure 1.1, and serve the entire range of science from advanced materials to life sciences. Meeting these challenges will require new tools that extend our reach into regions of higher spatial, temporal, and energy resolution. X-rays with energies above 10 keV offer capabilities extending beyond the nanoworld shown in Figure 1.1 due to their ability to penetrate into optically opaque or thick objects. This opens the door to combining atomic level information from scattering studies with 3D information on longer length scales from real space imaging with a resolution approaching 1 nm. The investigation of multiple length scales is important in hierarchical structures, providing knowledge about function of living organisms, the atomistic origin of materials failure, the optimization of industrial synthesis, or the working of devices. Since the fundamental interaction that holds matter together is of electromagnetic origin, it is intuitively clear that electromagnetic radiation is the critical tool in the study of material properties. On the level of atoms, electrons, and spins, x-rays have proved especially valuable. Future advanced x-ray sources and instrumentation will extend the power of x-ray methods to reach greater spatial resolution, increased sensitivity, and unexplored temporal domains. The purpose of this document is threefold: (1) summarize scientific opportunities that are beyond the reach of today's x-ray sources and instrumentation; (2) summarize the requirements for advanced x-ray sources and instrumentation needed to realize these scientific opportunities, as well as potential methods of achieving them; and (3) outline the R&D required to establish the technical feasibility of these advanced x-ray sources and instrumentation.

43 PARTICLE ACCELERATORS↗

Source size measurement options for low-emittance light sources

Radiation-based techniques for measuring electron source sizes are widely used as emittance diagnostics at existing synchrotron sources. Three of these techniques, namely, pinhole imaging, double-slit interferometry, and a K-edge filter-based beam position and size monitor system (ps-BPM), are evaluated for measuring source sizes at low-emittance storage rings. Each technique is reviewed with a detailed system description, design optimization, and practical considerations targeted for small source sizes. Pinhole imaging has the simplest setup and gives the beam profile in both transverse dimensions but with limited resolution. Double-slit interferometry has the highest resolution but with a limited detectable size range. The ps-BPM system shows reasonable resolution for monitoring small source sizes and divergence and can give real-time information of the source position and angle. New facilities may consider an integrated system that combines some or all of these techniques.

43 PARTICLE ACCELERATORS↗

Three-energy focusing Laue monochromator for the diamond light source x-ray pair distribution function beamline I15-1

The I15-1 beamline, the new side station to I15 at the Diamond Light Source, will be dedicated to the collection of atomic pair distribution function data. A Laue monochromator will be used consisting of three silicon crystals diffracting X-rays at a common Bragg angle of 2.83°. The crystals use the (1 1 1), (2 2 0), and (3 1 1) planes to select 40, 65, and 76 keV X-rays, respectively, and will be bent meridionally to horizontally focus the selected X-rays onto the sample. All crystals will be cut to the same optimized asymmetry angle in order to eliminate image broadening from the crystal thickness. Finite element calculations show that the thermal distortion of the crystals will affect the image size and bandpass.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fixed Target Serial Data Collection at Diamond Light Source

Serial data collection is a relatively new technique for synchrotron users. A user manual for fixed target data collection at I24, Diamond Light Source is presented with detailed step-by-step instructions, figures, and videos for smooth data collection.

Horrell, Sam↗

Overview of multi-element monolithic germanium detectors for XAFS experiments at diamond light source

An overview of multi-element monolithic germanium detectors being used at the X-ray absorption spectroscopy (XAS) beam lines at Diamond Light Source (DLS) is being reported. The hardware details and a summary of the performance of these detectors have also been provided. Recent updates about various ongoing projects being worked on to improve the performance of these detectors are summarized.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-efficiency in situ resonant inelastic x-ray scattering (iRIXS) endstation at the Advanced Light Source

In this paper, an endstation with two high-efficiency soft x-ray spectrographs was developed at Beamline 8.0.1 of the Advanced Light Source, Lawrence Berkeley National Laboratory. The endstation is capable of performing soft x-ray absorption spectroscopy, emission spectroscopy, and, in particular, resonant inelastic soft x-ray scattering (RIXS). Two slit-less variable line-spacing grating spectrographs are installed at different detection geometries. The endstation covers the photon energy range from 80 to 1500 eV. For studying transition-metal oxides, the large detection energy window allows a simultaneous collection of x-ray emission spectra with energies ranging from the O K-edge to the Ni L-edge without moving any mechanical components. The record-high efficiency enables the recording of comprehensive two-dimensional RIXS maps with good statistics within a short acquisition time. By virtue of the large energy window and high throughput of the spectrographs, partial fluorescence yield and inverse partial fluorescence yield signals could be obtained for all transition metal L-edges including Mn. Finally and moreover, the different geometries of these two spectrographs (parallel and perpendicular to the horizontal polarization of the beamline) provide contrasts in RIXS features with two different momentum transfers.

47 OTHER INSTRUMENTATION↗

Linac Coherent Light Source data analysis using psana

Psana ( Photon Science Analysis ) is a software package that is used to analyze data produced by the Linac Coherent Light Source X-ray free-electron laser at the SLAC National Accelerator Laboratory. The project began in 2011, is written primarily in C++ with some Python, and provides user interfaces in both C++ and Python. Most users use the Python interface. The same code can be run in real time while data are being taken as well as offline, executing on many nodes/cores using MPI for parallelization. It is publicly available and installable on the RHEL5/6/7 operating systems.

Damiani, D.↗

Environmental Remediation Science at Beamline X26A at the National Synchrotron Light Source- Final Report

The goal of this project was to provide support for an advanced X-ray microspectroscopy facility at the National Synchrotron Light Source, Brookhaven National Laboratory. This facility is operated by the University of Chicago and the University of Kentucky. The facility is available to researchers at both institutions as well as researchers around the globe through the general user program. This facility was successfully supported during the project period. It provided access to advanced X-ray microanalysis techniques which lead to fundamental advances in understanding the behavior of contaminants and geochemistry that is applicable to environmental remediation of DOE legacy sites as well as contaminated sites around the United States and beyond.

54 ENVIRONMENTAL SCIENCES↗

A spatial beam property analyzer based on dispersive crystal diffraction for low-emittance X-ray light sources

Abstract The advent of low-emittance synchrotron X-ray sources and free-electron lasers urges the development of novel diagnostic techniques for measuring and monitoring the spatial source properties, especially the source sizes. This work introduces an X-ray beam property analyzer based on a multi-crystal diffraction geometry, including a crystal-based monochromator and a Laue crystal in a dispersive setting to the monochromator. By measuring the flat beam and the transmitted beam profiles, the system can provide a simultaneous high-sensitivity characterization of the source size, divergence, position, and angle in the diffraction plane of the multi-crystal system. Detailed theoretical modeling predicts the system’s feasibility as a versatile characterization tool for monitoring the X-ray source and beam properties. The experimental validation was conducted at a bending magnet beamline at the Swiss Light Source by varying the machine parameters. A measurement sensitivity of less than 10% of a source size of around 12 µm is demonstrated. The proposed system offers a compact setup with simple X-ray optics and can also be utilized for monitoring the electron source.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗