Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “laser systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Ground-based laser DIAL system for long-term measurements of stratospheric ozone

A ground-based differential absorption lidar system has been implemented to make long-term, precise measurements of stratospheric ozone concentration profiles from about 20 to 50 km altitude. This lidar is located at an elevation of 2300 m in the San Gabriel Mountains, Southern California, and has been in operation since January 1988. A high power (100-W) excimer laser system and a 90-cm diam telescope are used to achieve the desired performance levels. This paper describes the implementation of the system and its operation including the procedures for data analysis. Examples of ozone profiles measured, and intercomparisons with measurements made by other instruments, are presented which show that the lidar, in its present configuration, is capable of producing high quality ozone measurements from 20 km up to at least 45 km.

Mcdermid, Stuart I.↗

Earth strain measurements with the transportable laser ranging system: Field techniques and planning

The potential of the transportable laser ranging system for monitoring the ground deformation around satellite ranging stations and other geodetic control points was examined with emphasis on testing the usefulness of the relative alteration technique. The temporal variation of the ratio of the length of each survey line to the mean length of all survey lines in a given area is directly related to the mean shear strain rate for the area. The data from a series of experimental measurements taken over the Los Angeles basin from a TLRS station at Mt. Wilson show that such ratios can be determined to an accuracy of one part in 10 million with a measurement program lasting for three days and without using any corrections for variations in atmospheric conditions. A numerical experiment using a set of hypothetical data indicates that reasonable estimates of the present shear strain rate and the direction of the principal axes in southern California can be deduced from such measurements over an interval of one to two years.

Nakamura, Y.↗

Geoscience Laser Ranging System - Estimated accuracy of geodetic parameters and their dependence on system characteristics

Covariance analysis of the performance of the Geoscience Laser Ranging System (GLRS) indicates that three-dimensional relative positions can be recovered to an accuracy of several millimeters over spatial scales from a few kilometers to several hundred kilometers and over temporal scales as short as several days. The key factors influencing the accuracy are range noise, number of targets and their locations, system pointing capability, dwell time on the targets, orbital geometry, and gravity field uncertainties. Based on the present trade-off studies, GLRS is designed to provide range measurements with 10 mm or better accuracy, fire at a rate of 40 pulses-per-second, point over a cone extending to 50 deg from nadir, and operate with a dwell time on individual targets of 2 s or less. Given a strain rate of 10 to the -14th/s, estimated GLRS accuracy parameters suggest that the deformation can be detected in less than a month if it extends over 100 km and in less than 6 months if it extends over 10 km.

Cohen, Steven C.↗

Polarization Loss Compensation in a Laser Transceiver System

JPL is developing a polarization-based sky tracking laser transceiver system in which some mirror coatings produce significant polarization losses that vary with tracking angle. We describe a useful method for dynamically compensating these effects.

optical systems design↗

2-Micron Laser Transmitter for Coherent CO2 DIAL Measurement

Carbon dioxide (CO2) has been recognized as one of the most important greenhouse gases. It is essential for the study of global warming to accurately measure the CO2 concentration in the atmosphere and continuously record its variation. A high repetition rate, highly efficient, Q-switched 2-micron laser system as the transmitter of a coherent differential absorption lidar for CO2 measurement has been developed in NASA Langley Research Center. This laser system is capable of making a vertical profiling of CO2 from ground and column measurement of CO2 from air and space-borne platform. The transmitter is a master-slave laser system. The master laser operates in a single frequency, either on-line or off-line of a selected CO2 absorption line. The slave laser is a Q-switched ring-cavity Ho:YLF laser which is pumped by a Tm:fiber laser. The repetition rate can be adjusted from a few hundred Hz to 10 kHz. The injection seeding success rate is from 99.4% to 99.95%. For 1 kHz operation, the output pulse energy is 5.5mJ with the pulse length of ~50 ns. The optical-to-optical efficiency is 39% when the pump power is 14.5W. A Ho:YLF laser operating in the range of 2.05 micrometers can be tuned over several characteristic lines of CO2 absorption. Experimentally, a diode pumped Ho:Tm:YLF laser has been successfully used as the transmitter of coherent differential absorption lidar for the measurement of CO2 with a repetition rate of 5 Hz and pulse energy of 75 mJ. For coherent detection, high repetition rate is required for speckle averaging to obtain highly precise measurements. However, a diode pumped Ho:Tm:YLF laser can not operate in high repetition rate due to the large heat loading and up-conversion. A Tm:fiber laser pumped Ho:YLF laser with low heat loading can operate in high repetition rate. A theoretical model has been established to simulate the performance of Tm:fiber laser pumped Ho:YLF lasers. For continuous wave (CW) operation, high pump intensity with small beam size is suitable for high efficiency. For Q-switched operation, the optimal energy extraction relies on the pump intensity, pump volume, and pump duration which is inversely proportion to the repetition rate. CW and Q-switched Ho:YLF lasers with different linear cavity configurations have been designed and demonstrated for a 30 W Tm:fiber pump laser. The CW Ho laser slope efficiency and optical-to-optical efficiencies reach 65% and 55%, respectively. The pulsed laser efficiency depends on the repetition rate. For 1 kHz operation, the optical-to-optical efficiency is 39% when the pump power is 14.5W. Currently, the injection seeding success rate is between 99.4% and 99.95%. After a ten thousand pulses, the standard deviation of the laser frequency jitter is about 3 MHz. It meets the requirements of highly precise CO2 concentration measurement. In conclusion, an injection seeded, high repetition rate, Q-switched Ho:YLF laser has been developed for a coherent CO2 differential absorption lidar. This master-slave laser system has high optical-to-optical efficiency and seeding success rate. It can potentially meet the requirements of the coherent detection of CO2 concentration by a differential absorption lidar technique.

Singh, Upendra N.↗

Temperature and humidity profiles in the atmosphere from spaceborne lasers: A feasibility study

Computer simulations of the differential absorption lidar technique in a space craft for the purpose of temperature and humidity profiling indicate: (1) Current technology applied to O2 and H2O lines in the .7 to .8 micrometers wavelength band gives sufficiently high signal-to-noise ratios (up to 50 for a single pulse pair) if backscattering by aerosol particles is high, i.e. profiling accurate to 2 K for temperature and 10% for humidity should be feasible within the turbid lower troposphere in 1 km layers and with an averaging over approximately 100 pulses. (2) The impact of short term fluctuations in aerosol particle concentration is too big for a one laser system. Only a two laser system firing at a time lag of about 1 millisecond can surmount these difficulties. (3) The finite width of the laser line and the quasi-random shift of this line introduce tolerable, partly systematic errors.

Grassl, H.↗

Advancement of High Power Quasi-CW Laser Diode Arrays For Space-based Laser Instruments

Space-based laser and lidar instruments play an important role in NASA s plans for meeting its objectives in both Earth Science and Space Exploration areas. Almost all the lidar instrument concepts being considered by NASA scientist utilize moderate to high power diode-pumped solid state lasers as their transmitter source. Perhaps the most critical component of any solid state laser system is its pump laser diode array which essentially dictates instrument efficiency, reliability and lifetime. For this reason, premature failures and rapid degradation of high power laser diode arrays that have been experienced by laser system designers are of major concern to NASA. This work addresses these reliability and lifetime issues by attempting to eliminate the causes of failures and developing methods for screening laser diode arrays and qualifying them for operation in space.

Amzajerdian, Farzin↗

A laser Doppler system for the remote sensing of boundary layer winds in clear air conditions

The system discussed uses a laser Doppler radar in combination with a velocity azimuth display mode of scanning to determine the three-dimensional wind field in the atmospheric boundary layer. An attractive feature of this CW monostatic system is that the ambient aerosol provides a 'sufficient' scattering target to permit operation under clear air conditions. Spatial resolution is achieved by focusing.

Lawrence, T. R.↗

A comparison of a coaxial focused laser Doppler system in atmospheric measurements

Measurements of atmospheric velocities and turbulence with the laser Doppler system were obtained, and the results compared with cup anemometer and hot-wire measurements in the same wind field. The laser Doppler velocimeter (LDV) is described along with the test procedures. It was found that mean values determined from the LDV data are within 5% of other anemometer data for long time periods, and the LDV measures higher velocities.

Karaki, S.↗

CO2 laser ranging systems study

The conceptual design and error performance of a CO2 laser ranging system are analyzed. Ranging signal and subsystem processing alternatives are identified, and their comprehensive evaluation yields preferred candidate solutions which are analyzed to derive range and range rate error contributions. The performance results are presented in the form of extensive tables and figures which identify the ranging accuracy compromises as a function of the key system design parameters and subsystem performance indexes. The ranging errors obtained are noted to be within the high accuracy requirements of existing NASA/GSFC missions with a proper system design.

Filippi, C. A.↗

Atmospheric refraction errors in laser ranging systems

The effects of horizontal refractivity gradients on the accuracy of laser ranging systems were investigated by ray tracing through three dimensional refractivity profiles. The profiles were generated by performing a multiple regression on measurements from seven or eight radiosondes, using a refractivity model which provided for both linear and quadratic variations in the horizontal direction. The range correction due to horizontal gradients was found to be an approximately sinusoidal function of azimuth having a minimum near 0 deg azimuth and a maximum near 180 deg azimuth. The peak to peak variation was approximately 5 centimeters at 10 deg elevation and decreased to less than 1 millimeter at 80 deg elevation.

Gardner, C. S.↗

Comparison of electrically driven lasers for space power transmission

High-power lasers in space could provide power for a variety of future missions such as spacecraft electric power requirements and laser propulsion. This study investigates four electrically pumped laser systems, all scaled to 1-MW laser output, that could provide power to spacecraft. The four laser systems are krypton fluoride, copper vapor, laser diode array, and carbon dioxide. Each system was powered by a large solar photovoltaic array which, in turn, provided power for the appropriate laser power conditioning subsystem. Each system was block-diagrammed, and the power and efficiency were found for each subsystem block component. The copper vapor system had the lowest system efficiency (6 percent). The CO2 laser was found to be the most readily scalable but has the disadvantage of long laser wavelength.

Deyoung, R. J.↗

Video Guidance Sensor System with Laser Rangefinder

A video guidance sensor system for use in automated docking of a chase vehicle with a target vehicle wherein the chase. vehicle includes a laser rangefinder that uses pulse or phase time of flight measurement to measure distance. The laser rangefinder includes a diode laser pulse or phase driver that produces an output signal to a timing element and simultaneously operates a laser diode. The laser diode produces an intense light beam of a predetermined wavelength which is directed to retroreflectors that are positioned on a passive target. The laser rangefinder includes an avalanche photodetector that produces a corresponding output signal when detecting light reflected from the retroreflectors. The timing element measures a time interval between the output of the laser diode and the detection of light and supplies a corresponding output signal to a computer in order to determine the range of the target vehicle relative to the chase vehicle.

Richard T Howard↗

Optics and lasers

Report describes twenty-seven optical concepts developed for holographic viewing, spectral transmission, and film camera technology. Articles include developments in laser-Doppler systems, laser beam deflection controls, X-ray photography, and camera components.

Source record↗

Research on techniques for laser ranging to optical corner reflectors on the moon. Research on laser techniques and single photo-electron detection and timing

Experimental studies using a pulsed LED, Cerenkov source, and a 100 ps laser were made of various photomultipliers and discriminator combinations. In addition, a new type of neodymium-YAG frequency doubled laser was used as the basis for the development of a stable, short pulse, high repetition rate laser system. This laser was then used in conjunction with atomic clocks to study the effect of gravitational potential on elapsed time. Avenues to promote the development of international cooperation in the area of lunar laser ranging were also explored.

Alley, C. O.↗

Laser measuring system for incremental assemblies

Wire-wrapped frame assemblies used in spark chambers and the like can be measured using a system which utilizes a laser, an interferometer, and a retroreflector to precisely measure distance. A light source and a photodetector are located adjacent the incremental assembly and mounted on a movable carriage. The interferometer is also mounted on the movable carriage, while the laser and retroreflector are positioned at either end of the carriage track. The carriage is moved along one edge of the incremental assembly between the retroreflector and the laser, and as the carriage is moved, the light from the light source to the photodetector is interrupted. This produces a trigger command to a control unit which in turn causes a distance measurement to be made. A printout is provided for each sampling trigger command to list such items as ideal position, actual position and amount of error.

Etzel, J. G.↗