Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “krypton”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Direct laser ion acceleration and above-threshold ionization at intensities from 10 21 W/cm 2 to 3 × 10 23 W/cm 2

Calculations on the dynamics of ions and electrons in near-infrared laser fields at intensities up to 3 × 10 23 W/cm 2 are presented here. We explore the acceleration of ions in a laser focus by conservation of canonical momentum during ionization events and by the ponderomotive force in the f/1 focal geometry required to reach such intensity. At intensities exceeding 10 23 W/cm 2 , highly charged ions are expelled from the laser focus before they can interact with the laser pulse at peak intensity, decreasing the predicted ionization yields of deeply bound states. We consider the interaction of a tightly focused, f/1 laser pulse with krypton at an intensity of 3 × 10 23 W /cm 2 and a pulse duration of 140 fs.We find that the ions and electrons are accelerated to energies in excess of 2 MeV/nucleon and 1.4 GeV, respectively. Ponderomotive expulsion of the parent ions decreases the total number of ultrarelativistic above-threshold ionization electrons produced by tunneling ionization from the K-shell states of krypton but does not change their energy spectrum.

74 ATOMIC AND MOLECULAR PHYSICS↗

Comparison of fission product release predictions using PARFUME with results from the AGR-1 safety tests

Safety tests were conducted on fourteen fuel compacts from AGR-1, the first irradiation experiment of the Advanced Gas Reactor (AGR) Fuel Development and Qualification program, at temperatures ranging from 1600 to 1800°C to determine fission product release at temperatures that bound reactor accident conditions. The PARFUME (PARticle FUel ModEl) code was used to predict the release of fission products silver, cesium, strontium, and krypton from fuel compacts containing tristructural isotropic (TRISO) coated particles during the safety tests, and the predicted values were compared with experimental results. Preliminary comparisons between PARFUME predictions and post-irradiation examination (PIE) results of the safety tests show different trends in the prediction of the fractional release depending on the species, and it leads to different conclusions regarding the diffusivities used in the modeling of fission product transport in TRISO-coated particles: • For silver, the diffusivity in silicon carbide (SiC) might be over-estimated by a factor of at least 102 to 103 at 1600°C and 1700°C, and at least 10 to 102 at 1800°C. The diffusivity of silver in uranium oxy-carbide (UCO) might also be over-estimated, but the available data are insufficient to allow definitive conclusions to be drawn. • For cesium, the diffusivity in UCO might be over-estimated by a factor of at least 102 to 103 at 1600°C, 105 at 1700°C, and 103 at 1800°C. The diffusivity of cesium in SiC might also over-estimated, by a factor of 10 at 1600°C and 103 at 1700°C, based upon the comparisons between calculated and measured release fractions from intact particles. There is no available estimate at 1800°C since all the compacts heated up at 1800°C contain particles with failed SiC layers whose release dominates the release from intact particles. • For strontium, the diffusivity in SiC might be over-estimated by a factor of 10 to 102 at 1600 and 1700°C, and 102 to 103 at 1800°C. These values might be somewhat over-estimated because the strontium retention during irradiation cannot be assessed a priori, which affects the magnitude of the calculated release during safety testing. The diffusivity of strontium in UCO cannot be derived from these heating tests, but it is assumed to be modeled correctly using the IAEA recommended value for kernel diffusivity. • For krypton, there is no reliable release data for compacts heated up at 1600°C, which includes all the compacts containing only intact particles. At 1700 and 1800°C, comparisons show an over-prediction of the release from compacts containing particles with failed SiC by 1 to 1.5 orders of magnitude. The available data from these heating tests do not allow to determine which of the TRISO-coating’s layers diffusivities are under or over-estimated.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Mechanisms of Retention and Transport of Fission Products in Virgin and Irradiated Nuclear Graphite

To fulfill the design and licensing requirements for advanced reactors, the U.S. Department of Energy (DOE) is specifically interested in targeted research to quantify the mechanisms of fission product transport and retention in graphitic grades that will likely be used in next-generation very/high temperature reactors, fluoride salt-cooled high temperature reactors and molten salt reactors. We have examined an integrated experimental-computational approach to determine the diffusivities of selected fission products – ruthenium (Ru) and silver (Ag) in five nuclear graphite grades – POCO AXF-5Q, POCO ZXF-5Q, PCEA, IG110, and NBG-18. Experimental investigation for diffusion of other fission products (iodine, cesium, and krypton) in graphite could not be carried out due to extreme evaporation due to high vapor pressure, despite several attempts incorporating various experimental schemes. Experimental investigation with irradiated graphite could not be carried out because necessary approval to transport irradiated graphite could not be obtained due to procedural reasons at ORNL and national policy change in UK. An effort was made to “produce” by ion sputtering, but it was discontinued because the outcome did not adequately represent irradiated graphite. Thin film and “cup-and-cap” methods were employed to deposit fission products, diffusion annealed were carried out in an argon atmosphere, and concentration profiles were determined by dynamic secondary ion mass spectroscopy depth profiling technique. Regardless of graphite type, anomalous diffusion behavior of Ru (i.e., lower than expected based on Arrhenius temperature dependence) at an intermediate temperature, around 600 to 700 °C, was observed. Diffusion behavior of silver on the other hand agreed well to the Arrhenius temperature dependence although the excessive evaporation of silver hampered the accurate determination of diffusivities at temperature higher than 900 °C. In general, silver was observed to diffuse faster than Ru in the temperature range compared from 500 to 900 °C, had consistently had higher pre-exponential factor corresponding to higher jump frequency. To understand the abnormal diffusional behavior of Ru in graphite in intermediate temperature range, a detailed microstructural analysis was carried out. Clustering of Ru into particles on the surface of graphite was observed around 700 °C corresponding to de-wetting and spheroidization. This change would influence the boundary condition of diffusion, although features of clustering was much smaller (<1 mm) than the SIMS raster size (120 x 120 mm). Raman spectroscopy also demonstrated that Raman peak intensity for Ru decreased significantly for samples annealed higher than 700 °C and presence of Ru in graphite altered the crystallinity of graphite. To further elucidate the abnormal diffusion behavior observed in intermediate temperature investigated, the vibrational properties of graphene, bilayer graphene and Kr atoms in bilayer graphene were investigated with molecular dynamics. Krypton, which is a fission product, was introduced between a bilayer graphene system to evaluate (i) whether the phonon dispersion curves change with high temperature in bilayer graphene (ii) whether the addition of Kr atoms between the bilayer introduces any significant change in the vibrational properties, and (iii) whether any change in the vibrational properties can be correlated to the diffusive behavior of Kr atoms. The results show that the Kr atoms indeed exhibit an anomalous diffusive behavior at 550°C. Phonon analysis shows that a few phonon frequencies are enhanced as much as 20 to 30 % with the addition of just 0.2 at.% Kr. So, this may explain the unexpected self-diffusivity of fission products.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Operation Experience with DC Photoemission Guns at Jefferson Lab

The JLab IR FEL injector is driven by a DC photoemission electron gun based on GaAs photocathodes. Since the FEL commissioning in 1998, the DC gun has been rebuilt several times for improved performance and/or for repairs. After demonstrating 9 mA CW and over 7000 Coulombs at 350kV for three consecutive years, the gun was rebuilt in 2008 due to a punctured insulator. Since then, the gun has been operating at 325V (lower voltage due to field emission) and has delivered beam at 65 pC bunch charge for VUV FEL operations, and 135pC for IR FEL operations at beam currents up to 4 mA CW. In February 2011, a copy of that gun was tested in the Gun Test Stand with a partially conductive insulator from Wesgo/Morgan to study bulk conductivity as charge drain for preventing insulator puncture by field emission. Close to 300 hours of high voltage testing showed that processing of field emission with partial pressure of Krypton gas is very effective. The gun held 500kV over 8 hours with 1E-4 Torr of Krypton. However, the gun could not hold more than 440kV under vacuum conditions, at which set point the insulator suffered a puncture. Various observations of Kr processing behavior and voltage-induced gas desorption will be presented. Financial support was provided by the Office of Naval Research, the Army Night Vision Laboratory, the Air Force Research Laboratory, the Joint Technology Office, the Commonwealth of Virginia, and by the U.S. DOE Basic Energy Sciences under contract No. DE-AC05-060R23177.

Hernandez-Garcia, Carlos↗

Field Emission Studies Toward Improving the Performance of DC High Voltage Photoelectron Guns

Field emission is the main mechanism that prevents DC high voltage photoemission electron guns from operating at the very high bias voltages required to produce low emittance beams. Gas conditioning is shown to eliminate field emission from cathode electrodes used inside DC high voltage photoelectron guns. Measurements and simulation results indicate that gas conditioning eliminates field emission from cathode electrodes via two mechanisms: sputtering and implantation, with the benefits of implantation reversed by heating the electrode. The field emission characteristics of 5 stainless steel electrodes varied significantly upon the initial application of voltage but improved to nearly the same level after helium and krypton gas conditioning, exhibiting less than 10 pA field emission at - 225kV bias voltage with a 50 mm cathode/anode gap, corresponding to a field strength ? 13 MV/m. Field emission could be reduced with either krypton or helium, but there were conditions related to gas choice, voltage and field strength that were more favorable than others. The field emission characteristics of niobium electrodes were compared to those of stainless steel electrodes using a DC high voltage field emission test apparatus. Out of 8 electrodes (6 niobium and 2 stainless steel), the best niobium electrode performed better than the best stainless steel electrodes. Large grain niobium exhibited no measurable field emission (< 10 pA) at 225 kV with 20 mm cathode/anode gap, corresponding to a field strength of 18.7 MV/m. Surface evaluation of all electrodes suggested no correlation between the surface roughness and the field emission current. Removing surface particulate contaminations and protrusions using an effective polishing and cleaning technique helps to prevent field emission. Mechanical polishing using silicon carbide paper and diamond paste is a common method of obtaining a mirror like surface finish on the cathode electrodes. However, it sometimes results rolled-over tips and embedded contamination. A different polishing technique was considered: electropolishing. Three stainless steel cathode electrodes with different initial surface roughness were electropolished by a commercial vendor, and evaluated inside a high voltage test stand. They exhibited less field emission than the diamond paste polished electrodes at the initial application of high voltage; but they were less receptive to ion implantation, which is a beneficial aspect of gas conditioning that serves to increase the work function of the cathode surface. Ultimately, the electropolished electrodes exhibited more field emission than diamond-paste polished electrodes.

Bastaninejad, Mahzad↗

Operation of an electron-bombardment ion source using various gases

An electron-bombardment ion thruster of the SERT 2 type was operated with xenon, krypton, argon, neon, nitrogen, helium, and carbon dioxide. The discharge performance with xenon, krypton, and argon was similar to that obtained previously with mercury. Mass spectrometer data indicated that the xenon contained no significant multiple ionization. Restriction of the beam area, with an associated decrease in discharge potential, was necessary to reduce multiple ionization with argon to a negligible level. This modification also resulted in more stable operation of the thruster. Performance with the remaining gases was poor because the basic thruster designed was optimized for operation with mercury.

Byers, D. C.↗

Electron-bombardment ion source operation using various gases.

Description of a modified flight-type SERT II ion thruster operated with xenon, krypton, argon, neon, nitrogen, helium, and carbon dioxide. The discharge performance with xenon, krypton, and argon was found to be similar to that obtained previously with mercury. Mass spectrometer data indicated that xenon could be operated efficiently with no significant multiple ionization. Restriction of the beam area, with an associated decrease in discharge potential, was necessary to reduce multiple ionization with argon to a negligible level. This modification also resulted in more stable operation of the thruster. Performance with the remaining gases was poor, but some future performance improvements may be realizable.

Byers, D. C.↗

Driving lamps by induction

An electrodeless lamp circuit with a coil surrounding a krypton lamp is driven by an RF input source. A coil surrounding a mercury lamp is tapped across the connection of the input central to the krypton-lamp coil. Each coil is connected in parallel with separate capacitors which form resonant circuits at the input frequency.

Laue, H. H.↗

Rare-gas analyses on neutron irradiated Apollo 12 samples.

Argon, krypton, and xenon from stepwise heating of five Apollo 12 rocks that had been irradiated to a neutron fluence of about 10 to the 19th neutrons/sq cm were analyzed mass-spectrometrically. The Ar40-Ar39 ages were determined and range from 3.18 plus or minus 0.06 x 10 to the 9th years to 3.32 plus or minus 0.06 x 10 to the 9th years. Trace elements Ba, Br, I, and U were measured via the neutron-induced reactions that produce isotopes of krypton and xenon. The following concentration ranges were observed: Ba, 46 to 70 ppm; Br, 48 to 146 ppb; I, 16 to 73 ppb; and U, 170 to 247 ppb.

Alexander, E. C., Jr.↗

The atmosphere of Mars near the surface - Isotope ratios and upper limits on noble gases

Several analyses of the Martian atmosphere have been carried out with the mass spectrometer in the molecular-analysis experiment. The ratios of abundant isotopes of carbon and oxygen are within 10 per cent of terrestrial values, whereas nitrogen-15 is considerably enriched on Mars. Argon-38 has been detected, and new limits on abundances of krypton and xenon have been set. The limit on krypton is sufficiently low to suggest that the inventories of volatile substances on Mars and on earth may be distinctly different.

Biemann, K.↗

Volumetric direct nuclear pumped laser

A volumetric direct nuclear pumped laser was developed in which the gas is a mixture of He-3 and a minority gas from the group of argon, krypton, xenon, chlorine and fluorine. The mixture of He-3 and the minority gas produces lasing with a minority gas concentration of from 0.01 to 10 percent argon, 1 percent krypton, 0.01 to 5 percent xenon and small concentrations of chlorine or fluorine.

Jalufka, N. W.↗

Quantum-chemical modeling of boron and noble gas dopants in silicon

The electron effects of the presence of boron and noble gas dopants in a model silicon lattice were investigated using a self-consistent charge extended Hueckel program. The extent of electronic interaction of the noble gas with the lattice is given by: Kr greater than Ar greater than Ne. Theoretically, boron diffusion in the presence of neon, argon or krypton was examined using a self-consistent charge extended Hueckel program. The net energy of interaction between boron and neon is strongly repulsive while argon-boron exhibits a region of relative stability; krypton exhibits behavior similar to argon though no region of stability was found for the range of separations used in the calculations. Finally, it is noted, from the relative energy of the topmost filled molecular orbital associated with boron (in an interstitial position), that activation of the boron does not require boron movement but can be accomplished by indirect transitions.

Aronowitz, S.↗

Development of a mass spectrometer system for the measurement of inert gases in meteorites

The study of the inert gases in meteorites has provided many clues as to the origin and evolution of the solar system. Particularly crucial and complex are the gases krypton and xenon. To accurately measure the isotopic compositions of these gases requires a mass spectrometer of high sensitivity and resolution. A previously unused and largely untested mass spectrometer system was brought to the point where it was ready for routine sample analyses. This involved, among other things, focusing the ion beam for optimal peak shape and sensitivity, documenting the instrument's response to a series of characteristic tests such as multplier gain checks, and interfacing the instrument to a computer to run the sample analyses. Following this testing and setting up, three iron meteorite samples were to be analyzed for argon, krypton, and xenon. The three samples were shown in prior work to possibly contain primordial heavy inert gases. Although these analyses have not yet been carried out, it is anticipated that they will be completed in the near future.

Palma, R. L.↗

A study of single and binary ion plasma expansion into laboratory-generated plasma wakes

Plasma expansion into the wake of a large rectangular plate immersed in a collisionless, supersonic plasma was investigated in laboratory experiments. The experimental conditions address both single ion and binary ion plasma flows for the case of a body whose size is large in comparison with the Debye length, when the potential difference between the body and the plasma is relatively small. A new plasma source was developed to generate equi-velocity, binary ion plasma flows, which allows access to new parameter space that have previously been unavailable for laboratory studies. Specifically, the new parameters are the ionic mass ratio and the ionic component density ratio. In a series of experiments, a krypton-neon plasma is employed where the ambient density ratio of neon to krypton is varied more than an order of magnitude. The expansion in both the single ion and binary ion plasma cases is limited to early times, i.e., a few ion plasma periods, by the combination of plasma density, plasma drift speed, and vacuum chamber size, which prevented detailed comparison with self-similar theory.

Wright, Kenneth Herbert, Jr.↗

Volatile inventory of Mars-2: Primordial sources and fractionating processes

The total volatile inventory of Mars has been modeled using meteoritic and presumed primordial abundances in the early solar system. Evidence is presented which indicates that the elemental abundances of the noble gases on Earth and Mars are similar, and their ratios are comparable to those in average carbonaceous chondrites with the exception of xenon and krypton. In order to account for presently observed variations in gas abundances, two primordial sources were used. One was the solar composition similar to the solar wind, and the other of carbonaceous grains that were the source for trace exotic components. For Mars, a model in which the early, high solar EUV flux with continued hydrogen production by differentiation results in mass fractionation of the primordial atmosphere, early depletion of xenon, and later depletion of gases lighter than krypton. The result is that the primordial Mars water inventory may have been on the order of 20 to 30 km if spread over the planet.

Pepin, R. O.↗

Solar, planetary, and other inert gases in two sieve fractions of a disaggregated Allende sample - A study by stepwise heating extraction

Inert gases released by stepwise heating of unaltered, strongly magnetic, and weakly magnetic samples from the 0-64 micron and the 105-250 micron fractions of a disaggregated and sieved sample of the Allende meteorite reveal the occurrence of both solar and planetary neon. The origin of the solar neon is thought to be implantation of solar wind ions. The origin of the planetary neon remains unresolved. Heavy isotope enriched components of krypton and xenon have been detected and there are some indications that a light krypton component may also be present. Other than a larger concentration of Xe-129 in the weakly magnetic samples, the signatures of the magnetic separates are isotopically very similar.

Palma, R. L.↗

Laboratory investigations of volatile trapping in comets

This research program consists of laboratory studies of the formation of ice at low temperatures to simulate the formation of comets in the outer solar nebula. The ice is condensed in the presence of various mixtures of gases at a given temperature, and then warmed to see at what temperatures the gases are released and how much gas was actually trapped. Our results to date indicate that the trapping of argon, krypton, and xenon in ice formed at approximately 50 K fractionates these gase in a way that fits the relative abundances found in the atmospheres of Mars and Earth. This is markedly different from the situation in chondritic meteorites, where the abundance of xenon is about equal to that of krypton. It appears that comets represent a better source for planetary volatiles than do the meteorites.

Owen, Tobias↗

13-kV Ion-Extraction System Being Developed for Inert Gas Ion Engines

A high-voltage ion optics design was chosen for an assumed outer planet or interstellar precursor mission that would require a long-life, high-power, high-specific-impulse krypton ion engine. Such an engine could support energetic space missions to the outer planets or beyond. Detailed performance and lifetime analyses and several inexpensive subscale grid tests were conducted at the NASA Glenn Research Center and at the Colorado State University under a NASA Glenn grant. A subscale grid set of the selected geometry shown was tested at voltages up to 13,000 V. This yielded a krypton ion beam current that would, when scaled to a full-size 50-cm diameter, produce an ion beam with a power of 30 kW at a specific impulse over 14,000 sec. The operational ion beam focusing limits, as a function of ion current per hole, were found to impose requirements of high uniformity on the discharge chamber plasma density. A full-size set of two-grid, 50-cm-diameter titanium ion optics has been fabricated and awaits testing.

Rawlin, Vincent K.↗