Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “kWh”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Benefits of Integration of Aerojet Rocketdyne and RTI Advanced Gasification Technologies for Hydrogen-Rich Syngas Production

The key objective for this project was to evaluate the potential to achieve substantial reductions in the production cost of H 2 -rich syngas via coal gasification with near-zero emissions due to the cumulative and synergistic benefits realized when multiple advanced technologies are integrated into the overall conversion process. In this project, Aerojet Rocketdyne’s (AR’s) advanced gasification technology (currently being offered as R-GAS™) and RTI International’s (RTI’s) advanced warm syngas cleanup technologies were evaluated via a number of comparative techno-economic case studies. AR’s advanced gasification technology consists of a dry solids pump and a compact gasifier system. Based on the unique design of this gasifier, it has been shown to reduce the capital cost of the gasification block by between 40 and 50%. At the start of this project, actual experimental work had been demonstrated through pilot plant systems for both the gasifier and dry solids pump. RTI’s advanced warm syngas cleanup technologies consist primarily of RTI’s Warm Gas Desulfurization Process (WDP) technology, which effectively allows decoupling of the sulfur and CO 2 removal allowing for more flexibility in the selection of the CO 2 removal technology, plus associated advanced technologies for direct sulfur recovery and water gas shift (WGS). WDP has been demonstrated at pre-commercial scale using an activated amine carbon dioxide recovery process which would not have been possible if a majority of the sulfur had not been removed from the syngas by WDP. This pre-commercial demonstration of RTI’s advanced warm syngas cleanup system was conducted in parallel to the activities on this project. The technical data and cost information from this pre-commercial demonstration were extensively used in this project during the techno-economic analysis. With this project, both of RTI’s advanced WGS technologies were investigated. Because RT’s advanced fixed-bed WGS (AFWGS) process was successfully implemented in the WDP pre-commercial demonstration test mentioned above, this technology was used as part of RTI’s advanced warm syngas technology package for the techno-economic analyses for this project. RTI’s advanced transport-reactor-based WGS (ATWGS) process was still conceptual at the start of this project, but one of the tasks for this project was to evaluate the technical feasibility of this technology. In each of the three application-based comparison studies conducted as part of this project, the reference case was based on an existing Department of Energy National Energy Technology Laboratory (DOE/NETL) system study. Each of these references cases used existing commercial technology and the system resulted in > 90% carbon capture. In the comparison studies for the use of the hydrogen-rich syngas generated in either an Integrated Gasification Combined Cycle (IGCC) or a Coal-to-Methanol (CTM) plant, the comparison cases consisted of the reference case, a case with the integration of each individual advanced technology (either AR or RTI), and finally a case with the integration of all the advanced technologies (AR and RTI combined). In the Coal-to-Liquids (CTL) comparison study, the comparison study consisted of only three cases, which included a reference case, a case with just RTI’s advanced syngas cleaning technology, and a case with AR’s and RTI’s advanced technologies. The results from these comparison studies showed that the integration of the advanced technologies did result in substantial benefits, and by far the greatest benefits were achieved for cases integrating all the advanced technologies. For the IGCC study, the fully integrated case resulted in a 1.4% net efficiency improvement, an 18% reduction in capital cost per kW of capacity, a 12% reduction in the operating cost per kWh, and a 75–79% reduction in sulfur emissions. For the CTM case, the fully integrated plant resulted in a 22% reduction in capital cost, a 13% reduction in operating costs, a > 99% net reduction in sulfur emissions, and a reduction of 13–15% in CO 2 emissions. Because the capital cost represents over 60% of the methanol Required Selling Price (RSP), the significant reduction in the capital cost for the advanced technology case resulted in an 18% reduction in methanol RSP. For the CTL case, the fully integrated plant resulted in a 16% reduction in capital cost, which represented a 13% reduction in diesel RSP. Finally, the technical feasibility analysis of RTI’s ATWGS process demonstrated that a fluid-bed catalyst with sufficient attrition resistance and WGS activity could be made and that the process achieved about a 24% reduction in capital cost compared to a conventional fixed-bed commercial process.

08 HYDROGEN↗

Rebound Effects in the Context of Developing Country Efficiency

Energy efficiency-related “rebound effects” usually refer to the tendency of most consumers to increase their use of energy services in response to efficiency measures that have reduced their energy costs. This phenomenon is one reason why energy efficiency policies often result in lower energy savings than engineering-based estimates predict. Rebound effects have been the subject of intense debate in the field of energy efficiency policy for many years.1 In the past, the focus of this debate has been on the perceived loss of the expected energy savings and related benefits resulting from the rebound effects. However, more recently, there has been a growing recognition that policymakers need to consider the health, economic and other non-energy benefits that often result from the increase in energy services represented by user “rebound effects”. This is especially true in developing countries where basic energy service demands—such as lighting, heating, cooling, and refrigeration of food—are often not being met. As economic conditions improve and household incomes increase, demand for increased energy services (such as space conditioning and appliances) tends to rise rapidly. Improving energy efficiency reduces the amount of energy needed to produce one unit of energy service output (for example an hour of cooling at 21°C delivered for X vs Y kWh). Greater efficiency therefore often enables more rapid increased in energy services (and sometimes access), expanding the amount of services that can be provided by a fixed amount (or cost) of energy.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Final Report to the Department of Energy Renewable Energy and Energy Efficiency

The Pala Band of Mission Indians was awarded a DOE-EERE Solar Energy Grant for FY 2016 and 2017. The project involved installing a 94.8 kW DC photovoltaic (PC) solar system on the Pala Fire Station to offset up to 95% of grid-derived energy and reduce overall CO 2 generation from the facility. Pala successfully installed rooftop and carport-mounted solar panels at the fire station, and to date has generated of 219,227 kWh of energy and offset 274,034 pounds of CO 2 . The project was successfully executed, and we recommend other tribes to undertake similar projects if they are located in areas with sufficient solar exposure. DOE should continue to make these funds available to tribes.

14 SOLAR ENERGY↗

The Cost of Saving Electricity Through Energy Efficiency Programs Funded by Utility Customers: 2009–2015

The average cost to utilities to save a kilowatt-hour (kWh) in the United States is 2.5 cents, according to the most comprehensive assessment to date of the cost performance of energy efficiency programs funded by electricity customers. These costs are similar to those documented earlier. Cost-effective efficiency programs help ensure electricity system reliability at the most affordable cost as part of utility planning and implementation activities for resource adequacy. Building on prior studies, Berkeley Lab analyzed the cost performance of 8,790 electricity efficiency programs between 2009 and 2015 for 116 investor-owned utilities and other program administrators in 41 states. The Berkeley Lab database includes programs representing about three-quarters of total spending on electricity efficiency programs in the United States.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Low cost modular plasma system for reforming of natural gas

The initial aim of this project was to develop a low-cost compact, modularly scalable, point of use, on demand production system for the reforming of natural gas (NG) into products such as acetylene, hydrogen and other related hydrocarbons. Based on a pulsed dielectric barrier discharge (DBD), the fast rising voltage pulses produced by the system causes the dielectric breakdown of the gas to lag behind the rapid voltage increase so that a voltage greater than the static breakdown voltage of the gas, called an overvoltage, is briefly attained. The century long commercial use of the DBD discharge to push the highly endothermic oxygen to ozone reaction served as an additional motivation. The project meets the recommendations of the National Research Council 2007 report on plasma science for a greater investment in low temperature plasma science and engineering. An important finding is that the method investigated has a high specific energy requirement (SER) of the order of 1,000 to 5,000 kWh per kg of hydrogen, and a corresponding low efficiency of only ~0.1 to 0.5% of converting electrical into chemical (ΔH, ΔG) energy. This compares unfavorably with 52 kWh/kgH 2 required for NG thermal plasma reforming, or a pulsed spark discharge, Lotfalipour et. al, and Gao et. al. (For comparison electrolysis of water into hydrogen and oxygen gas requires only 45 to 80kWh/kgH 2 ). This project garnered data with different reactor configurations, materials, gases and mixtures including NG, methane, hydrogen, propane, argon, nitrogen and air, gap sizes ranging from 0.5 to 4.1 mm, electrode areas from 5 to 460 cm, voltages to 27 kV, pulse frequencies to 20 kHz and peak currents into the hundreds of amperes, temperatures to 625 °C and pressures from 15 mbar to 2 bar. An SRS 300 residual gas analyzer (RGA) yielded quadrupole mass spectrometry (QMS) data on the reformate. To analyze the data we extended the public domain software OpenChrom®, Wenig, to QMS data, yielding accurate identification and quantitative data on reformate products. This extension of OpenChrom® is applicable beyond this project and is a significant contribution to the general community of researchers. The documentation is available on the internet, see Whitlock, and a copy has been appended to this report. The main product of methane and natural gas plasma reforming is hydrogen, constituting ~90% of the products, followed by 1% to 10% ethane, propane, ethylene, acetylene and isobutene. Neopentane, propene, butane and pentane constitute less than 1 % of product. Adding a nickel catalyst increases the selectivity for hydrogen. Carbon nanosheets (graphene), a product of commercial interest, were synthesized by plasma reforming of acetylene at low pressure. The reformate analysis shows hat saturated and branched hydrocarbons are favored compared with unsaturated and linear hydrocarbons. For example, ethane, propane, iso-butane, 2-methyl butane, and 2-methyl pentane are produced in higher amounts compared with unsaturated and linear components. At low pressure acetylene and ethylene production rate is higher and propane production lower. We developed a recirculating system in which hydrogen is removed through a permeable membrane as fast as it is being produced by the reactor and the remaining products are recirculated at a high flow rate of several liters per minute. This keeps the concentration of H 2 in the reactor low, while achieving a total output concentration of 79%, high enough for pressure swing adsorption to be used for further purification. The recirculating system could be used with other gas reforming technologies. We report on four different reactors,1) a spark discharge reactor, 2) a standard DBD cylindrical reactor, 3) a small DBD reactor where catalyst powder can be quickly loaded onto a carrier to investigate the effect of the plasma on the catalyst and the effectiveness of the of the catalyst in promoting gas reformation and 4) a configurable DBD reactor to study the performance effects of dielectric selection, electrode gap distance, and electrode/dielectric interface on plasma reactor operation. This project achieved a commercializable 1kW plasma system including reactors a plasma pulse generator and a gas supply module.

03 NATURAL GAS↗

High Energy Storage Capacity Low Cost Iron Flow Battery

A new flow battery was proposed that utilizes low cost materials: iron as the only active element, cheap aqueous electrolytes, and inexpensive separators. During charging, ferrous iron (Fe 2+ ) is oxidized to ferric iron (Fe 3+ ) at the positive electrode while it (Fe 2+ ) is reduced to form iron metal (Fe 0 ) at the negative electrode. Because iron is plated at the negative electrode during charging, conventional electrode structures couple the energy storage capacity and the power rating of the battery. In order to decouple the energy and power ratings and regain the economic advantages of a flow battery, a slurry electrode design was proposed for use as the negative electrode. The slurry electrode is made by flowing electrically conductive particles in an electrolyte containing the dissolved iron species. On charging, iron is plated onto the particles. The particles can then carry the iron metal out of the cell to be stored in external reservoirs. This project looked to develop a slurry for the negative electrode of the all-iron flow battery that can operate at 200 mA/cm 2 with <100 mV overpotential, be pumped with parasitic energy costs < 10%, and promote plating on the particles. A scalable and stackable cell design of 1100 cm 2 was developed. The project was initially under contract in mid-January 2013. The project was converted from a one-year proof of concept seedling to an additional two-year program, then extended with an 18-month plus-up, and finally with an additional 6-month approved cost-overrun. During the seeding project, the concept of plating on carbon particles in a slurry was demonstrated. However, this was accomplished with high-cost multi-walled carbon nanotubes as the slurry material. The following two-year program discovered several low-cost carbon blacks that could also be used in this application. These findings were supported by an analysis that demonstrated the effectiveness of the carbon that takes into account not just the effective electronic conductivity of the slurry, but also the surface area per volume of the slurry. It was demonstrated that stable, flowable slurries could be created with these carbons, even when the carbons where fully loaded with iron during charging. During the two-year program, laboratory-scale 50 cm 2 single-cells demonstrated charge-discharge cycling at current densities of 150 mA/cm 2 and energy efficiencies of >50%. Meanwhile, cost modeling continued to show promise for this energy storage approach. Following the conversion period, the overall objective of the nominally 18-month plus up period was to close the technical gap of a 25X scale-up and reduce risk to enable commercial investment required to develop a slurry iron flow battery product. A specific objective was to demonstrate 150 cycles of performance exceeding 70% energy efficiency with a 10-cell stack of 1156 cm 2 cells operating at 100 mA/cm 2 . The 10-cell short stack was designed to have a power delivery rating of approximately 1 kW, which represents a size commensurate with the requirements of our commercialization partner at that time. A complete battery support system for the full-size cell was designed, fabricated, and tested. This includes pumps (multiple types were considered, and constant volume hose pumps were found to be acceptable for performance and cost), electrolyte rebalance reactor, and sensors and control systems. The support system proved to be well-behaved and worked well. A new low-cost membrane was developed for this system based on a microporous polymer support with a layer of hydrogel polymer. The membrane had low resistivity, and significantly reduced pressure driven fluid flow across the membrane (as compared to the un-coated microporous support). This membrane approach was scaled-up in conjunction with a commercial toll coating company, and a large amount of membrane was manufactured to support large cell and stack testing. A new concept for an electrolyte rebalance reactor to react hydrogen gas from the negative electrolyte (from plating inefficiency) with excess ferric ion in the positive electrolyte was developed. This design was very simple, low cost, and effective. The full scale 1156 cm 2 single-cell was designed, modeled, fabricated and tested. Modeling showed that uniform flow-distribution should be obtained with the designed flow distributor. The design took into consideration the need to stack the cells, and components were fabricated for a ten-cell stack. Testing of the cell for charge and discharge demonstrated current densities of 50 mA/cm 2 with efficiencies of 50%. However, optimization and long cycling could not be accomplished because the slurry electrode would plug within the cell and block the flow. This would shut down the cell after several charge-discharge cycles. Various approaches were pursued to address this problem with some progress. However, there was not adequate time to find solutions to the problem although several promising approaches were identified for future work. The final deliverable for this proposed 18-month effort was to be a 1 kW, 6 kWh slurry flow battery, with complete balance of plant, ready for testing at an ARPA-E ‘Charges’ site with an estimated capital cost less than $\$ $45/kWh for a six-hour system (excluding power electronics). The deliverable milestone was not achieved for reasons mentioned above related to the slurry plugging. At the completion of this project, it was determined that the cost targets are achievable. The cost estimate for a 1 MW system with a one-hour capacity was estimated at $\$ $140/kWh (including power electronics) and for a six-hour system was estimated at $\$ $40/kWh (including power electronics). These costs include the battery, the balance of plant, the power conditioning and a concrete pad. This program resulted in three patents including the slurry-based iron flow battery, the rebalance reactor, and the membrane separator. At the time of this report, slurry-based iron flow battery patents have been issued in the US, China, Japan, Korea, and Europe. The other patent applications were under various stages of examination. A licensee was identified and the company initiated a scale-up and development program to take this technology to the marketplace, and CWRU staff have transferred their know-how and knowledge base to the company. This technology will enhance the economic and energy security of the United States by enabling the use of intermittent renewable energy technology, such as wind and solar power, as dispatchable resources. This report summarizes the results of this research and development program.

25 ENERGY STORAGE↗

Implications of Rate Design for the Customer-Economics of Behind-the-Meter Storage

This work provides insights for the two main sources of bill savings for residential and commercial customers – demand charge reductions and arbitrage of energy charges – considering a range of customer profiles and retail rate designs. Storage can reduce monthly demand charges, which are dependent on the customer’s billing demand in kW rather than the amount of energy they consume in kWh, by charging during times of low energy consumption and discharging during peak consumption hours, thereby reducing peak power consumption from the grid. Storage can also reduce electricity bills by charging the storage during low-priced hours and discharging during high-priced hours, taking advantage of price-differentials of time-varying rates. This study considers a variety of demand charge designs and rates that allow for energy arbitrage.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Water Footprint of European Rooftop Photovoltaic Electricity based on Regionalised Life Cycle Inventories

The water use of photovoltaic (PV) electricity has been investigated in very few studies so far, which may be due to the low water demand of PV systems during operation. In this study, the water consumption and water withdrawal of electricity generated by PV systems were assessed by considering all life cycle stages and by taking account of country-level regional differences in water availability. The life cycle inventories of the manufacture of monocrystalline silicon (mono-Si) and cadmium telluride (CdTe) PV modules are based on data collected between 2010 and 2013 and take account of the shares of different countries in total global production. The water use in the life cycle inventories of European rooftop PV systems and conventional electricity generation technologies was regionalised to the country or region (such as continents, political or geographic entities of several countries) level and complemented by the share of water lost by evaporation. The AWARE (Available WAter REmaining) method was used to assess the water stress impact caused by water consumption and water withdrawal of electricity generation by European rooftop PV systems as well as by reservoir hydroelectric power plants and large-scale hard coal and nuclear power plants in Europe. The functional unit of this analysis is 1 kWh of alternating current (AC) electricity (at busbar). The life cycle inventories were linked to KBOB (Coordination Group for Construction and Property Services) life cycle inventory data DQRv2:2016, which are based on ecoinvent data v2.2 and contain updated life cycle inventory data in relevant economic sectors. This study was financed by the Swiss Federal Office of Energy (SFOE) and carried out in the framework of the Task 12 of the Photovoltaic Power Systems Programme (PVPS) of the International Energy Agency (IEA).

14 SOLAR ENERGY↗

Cost of Saving Electricity Through Efficiency Programs Funded by Customers of Publicly Owned Utilities: 2012–2017

This report finds that energy efficiency programs for customers of publicly owned utilities saved electricity at an average cost of 2.4 cents per kilowatt-hour (kWh) from 2012 to 2017. Utilities use such cost performance metrics to assess effectiveness of efficiency program portfolios, determine what programs to offer customers, and, more broadly, ensure electricity system reliability at the most affordable cost as part of electric utility resource adequacy planning and resource procurement processes. The study analyzed efficiency program data reported by 111 program administrators for 219 publicly owned utilities in 14 states — about 90 percent of the municipal utilities and public utility districts that report the data to the Energy Information Administration (EIA). The data represent 88 percent of all spending and 75 percent of all savings that publicly owned utilities reported to EIA in those years. Berkeley Lab used data from several sources, including data provided directly by American Public Power Association members, publicly available annual reports and regional data collections.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Hot Topic Brief: Emerging Policies for Mobilizing Private Sector Investment into Clean Energy in the Philippines

The Philippines has one of the highest electricity prices for commercial and residential consumers in the Association of Southeast Asian Nations (ASEAN) region with prices between $0.12 (commercial) and $0.20 (residential) per kilowatt-hour (kWh) (ERIA 2018). Significant reliance on imported coal and diesel is the primary cause of this cost to ratepayers. This 'hot topic brief' details new policies in the Philippines designed to diversify the country's fuel-mix and the opportunities for investments in renewable energy to reduce prices for consumers and industry. This brief focuses on two recent policies: 1. Renewable Portfolio Standard (RPS): The RPS establishes mandatory targets for each electric distribution utility--both publicly and privately owned--to procure renewable energy through 2030. 2. Green Energy Option Program (GEOP): The GEOP enables companies to independently procure renewable energy from third-party power producers, which can be used to help meet private sector renewable energy goals, unlock lower electricity costs, and increase energy security.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Unique Single-Axis Tracking Planar Waveguide Optical Collector for CSP Modules

During the project Agira was pursued: (a) R&D efforts leading to the development of an innovative and revolutionary future-generation waveguide concentrating solar collector that will have improved value or productivity when compared to best-in-class, near-commercial concentrating solar power (CSP) solar collector technologies; (b) demonstrate results supporting that the proposed innovation meets or goes beyond the 6 cents per kWh levelized cost of electricity (LCOE) goals set forth by the SunShot Initiative (c) pursue clear market- and application-driven objectives and partnerships as part of a credible pathway to commercial development and eventual deployment. The novel optical approach consisted of a primary light bending optics converting normal incidence light to shallow angles which is then input onto a shallow secondary reflector which redirects and concenrates the light onto the evacuated solar tube.

14 SOLAR ENERGY↗

ENERGY STAR for Tenants: An Online Energy Estimation Tool for Commercial Office Building Tenants

The commercial building sector consumes over 18% of the total energy in the United States. According to the 2012 Commercial Building Energy Consumption Survey (CBECS), office buildings comprise nearly 16 billion square feet of floor space and consume 253 billion kWh of energy annually. Office buildings represent nearly one-fifth of the energy consumed by commercial buildings, more than any other building type. Therefore, monitoring and reducing energy consumption in office buildings has become an increasingly important focus across the United States. The goal of the ENERGY STAR for Tenants program is to recognize office building tenants who demonstrate commitment to energy efficiency and environmental stewardship. Tenants seeking recognition must complete five major steps: estimate energy use, meter energy use, use efficient lighting, use efficient equipment, and share data. NREL is responsible for the underlying analysis performed for step one, estimating energy use. An online survey was developed for tenants to input information about their office space and its internal loads. NREL performed a parametric analysis across a large parameter space of office buildings. The analysis results were processed to map the user inputs to output energy ranges. The mappings enable the web tool to provide users with instant energy usage estimates based on a limited number of inputs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

White Earth Community Facilities Solar PV Project (Final Report)

Funded project was for the design, installation, and performance monitoring of 2 - 11.4 kW AC and 1-38.0 kW AC ground-mount solar installations for three tribal community facilities, for a total 60.8 kW AC, including a daycare facility and two community centers. Of in excess of 120 tribal buildings these facilities had showed the best promise for implementing solar, based upon site characteristics, roof loads, roof orientation and building size. The White Earth Nation seeks to move forward proactively to address the following project goals and objectives: 1) Reduction of energy costs, 2) Increasing energy security for Indian Tribes and tribal members, 3) Adding 60.8 KW in renewable energy generation (solar PV), 4) Offsets, reduces coal-fired electric energy demand by 76,397 kWh, 817,448 Source Energy Btu annually, and S) Meets the overall solar PV target set in the FOA.

14 SOLAR ENERGY↗

Advanced Anode for Internal Reforming and Thermal Management in Solid Oxide Fuel Cells

Solid oxide fuel cell (SOFC) is an efficient and clean electrical power generation system compared to conventional combustion based technologies with energy efficiency reaching as high as 85-90% in co-generation mode (electricity and heat). Other advantages of SOFCs are hybridization, modularity of construction, small CO 2 foot print per kWh of generated electricity and fuel flexibility. Hydrocarbons present in the gaseous fuel is utilized in SOFCs by internal or external reforming. There are two different internal reforming concepts: Direct Internal Reforming (DIR) and Indirect Internal Reforming (IIR). For DIR operation, the endothermic reforming reaction and the exothermic reaction from the oxidation reaction are operated together in the single unit eliminating the requirement for a separate fuel reformer. This configuration also simplifies the overall system design, making SOFC more attractive and efficient means of producing electrical power. The main advantage of the DIR type of operation is that the H 2 or CO consumption by the electrochemical reaction could directly promote the conversion of methane at the anode side of the fuel cell resulting in high conversion and high efficiency. The DIR operation, however, requires an anode material that has desired dual catalytic (hetero and electro) properties for reforming reaction and electrochemical reactions. The anode materials also need to remain resistant to carbon formation at the operating temperature and atmosphere with stable cell performance. Another requirement is to match the reforming reactions and electrochemical reactions to avoid local cooling or overheating, which can result in mechanical failure due to thermally induced stresses. Direct internal reforming (DIR) of hydrocarbon fuels simplifies the overall SOFC system design making it more attractive and efficient for producing electrical power. Low cost alloy anodes for distributed internal reforming of methane and other hydrocarbon fuels offer increased fuel-flexibility, reliability, and long term performance stability of solid oxide fuel cells (SOFC). The research program examined modification of the chemical compositions and microstructure of high entropy alloy (HEA) anode materials using thermochemical calculations and process simulation and modeling to achieve distributed reforming over the entire anode to eliminate hot zones. Cell fabrication and testing of the HEA anodes using button cell configuration has been performed to demonstrate the advantages of new anode over traditional Ni-YSZ anodes for distributed reforming and carbon free operation. Technical accomplishments include identification and synthesis of HEA carbon-resistant anode, demonstration of reduction in reforming rate confirmed by GC and modelling data validating effectiveness for thermal management in cell/stacks, electrochemical testing of HEA anode in single cell (HEA-GDC||YSZ||LSM-YSZ) and Characterization of pretest and posttest anode materials by TEM and SEM-EDS confirming carbon-free operation.

30 DIRECT ENERGY CONVERSION↗

Making Northway, Alaska Resilient and Sustainable Through Energy Efficiency and Solar Power

This project implemented energy efficiency measures and installed 6 kW solar arrays on three community buildings in Northway, Alaska, in a collaboration between the Department of Energy - Office of Indian Energy Policy and Programs, the Northway Village Council (NVC), the Tanana Chiefs Conference (TCC), and the Alaska Native Tribal Health Consortium (ANTHC). Northway is a small community in interior Alaska, close to the Canadian border, with high fuel and energy costs: $3.00 per gallon of diesel and $0.56 per kWh, respectively, in 2016, when the project began. The energy efficiency and solar power installation plans aligned with Northway’s long-term energy goals of increasing renewable energy and decreasing reliance on fossil fuels, per the Northway Community Energy Action Plan, the Alaska Interior Regional Energy Plan, and TCC Comprehensive Economic Development Strategy. The project focused on three buildings: (1) the community hall (and later office) building, (2) the washeteria building, and (3) the water/sewer garage. It included multiple directions for energy efficiency measures, such as installing LED lighting upgrades, programmable thermostats, vending machine energy misers, efficient pumps, and adding glycol loops at the water/sewer plant. Since the village has a high potential for solar energy, in order to increase resilience and decrease costs, solar systems were installed on three community buildings. Later, a battery was installed in the community hall to capture solar power produced but not used during the day, and allow the flexibility to use that power during evening and night, further decreasing the reliance on grid power for that building. Electricity savings realized by the village between 2011-2012 and 2018-2019 by improving energy efficiencies in the buildings and adding solar was 23%. This is despite the community hall doubling in size during the same time period. If that is taken into consideration (by adding community hall usage into the 2011-2012 usage one additional time), the energy savings from 2011-2012 to 2018-2019 was 37%.

14 SOLAR ENERGY↗

A Rechargeable Carbon-Oxygen Battery for Efficient, Low-Cost Energy Storage

As part of the Cyclotron Road program, Noon Energy Inc investigated the feasibility of a new class of rechargeable flow battery for long-duration energy storage at the 100+ hour storage capacities needed to make intermittent solar/wind power available 24/7 year-round. Whereas conventional batteries store energy in relatively expensive metals like cobalt, lithium, and vanadium, the new battery stores energy in abundant, ultra-low-cost carbon and oxygen, storage media that cost well below $1 per kWh capacity (less than the cost of their containers). It also can operate with a high roundtrip energy efficiency of ~80% and has 10x higher energy density than conventional aqueous flow batteries, even higher than lithium ion batteries at system level. These properties make it suitable for a variety of potential stationary energy storage applications as well as for electric transportation vehicles (long-haul marine shipping and trucking), so determining the best product-market fit and market entry was a key outcome of Noon’s Cyclotron Road fellowship. Noon had demonstrated initial materials development and proof-of-principle testing before the fellowship. Overall, within the fellowship Noon carried out key initial technology development in market applications, system design, risk assessment and prototyping.

25 ENERGY STORAGE↗

Comprehensive Total Cost of Ownership Quantification for Vehicles with Different Size Classes and Powertrains

In order to accurately compare the costs of two vehicles, the total cost of ownership (TCO) should consist of all costs related to both purchasing and operating the vehicle. This TCO analysis builds on previous work to provide a comprehensive perspective of all relevant vehicle costs of ownership. In this report, we present what we believe to be the most comprehensive explicit financial analysis of the costs that will be incurred by a vehicle owner. This study considers vehicle cost and depreciation, financing, fuel costs, insurance costs, maintenance and repair costs, taxes and fees, and other operational costs to formulate a holistic total cost of ownership and operation of multiple different vehicles. For each of these cost parameters that together constitute a comprehensive TCO, extensive literature review and data analysis were performed to find representative values in order to build a holistic TCO for vehicles of all size classes. The light- and heavy-duty vehicles selected for analysis in this report are representative of those that are on the road today and expected to be available in the future. Important additive analyses in this study include systematic analysis of vehicle depreciation, in-depth examination of insurance premium costs, comprehensive maintenance and repair estimates, analysis of all relevant taxes and fees, and considerations of specific costs applicable to commercial vehicles. We find that cars depreciate faster than light trucks and that older plug-in electric vehicles have a greater depreciation rate than newer electric vehicles. Light-duty vehicle (LDV) insurance costs show comparable costs for different powertrains, and lower costs for larger size classes. Medium- and heavy-duty vehicle (MHDV) insurance costs vary significantly by vocation. Electric and electrified powertrains have lower maintenance and repair costs than internal combustion engine (ICE) powertrains for all vehicle sizes, relative to vehicle price. MHDV maintenance and repair costs depend heavily on vocation and duty cycle. LDV taxes and fees are comparable across powertrain types and size classes, though marginally higher registration fees exist for alternative fuel vehicles. MHDV fees depend on the vocation, weight rating, and state. Many electric tractor trailers would be affected by additional battery weight, reducing the available payload capacity, and this cost can be substantial. Electric vehicle charging for commercial vehicles can be time-consuming; labor rates can cause this cost to dominate TCO. With improved knowledge of each of the cost components, we calculate a lifetime TCO for comparison across vehicles of different types and attributes. For a simulated small sport utility vehicle in 2025, modeled using Autonomie, the hybrid electric vehicle (HEV) has the lowest cost, followed by the conventional ICE vehicle. For MHDV, TCO can be drastically different depending on the vocation. Long-haul vehicles typically have the lowest per-mile costs. Excluding labor costs, the class 4 delivery has a comparable TCO to the day cab. Vocational trucks, refuse trucks, and transit buses have a high per-mile cost of ownership due to maintenance and insurance. For all of these vehicles, the cost of operating the vehicle is heavily weighted by the labor of the driver, followed by the fuel costs. While the HEV begins as the lowest cost powertrain for passenger vehicles, fuel cells are forecast to reach cost parity by 2030 when hydrogen prices reach $\$ 5$/kg while battery electric vehicles (BEV) reach cost parity by 2035 at a battery cost of $\$ 98$ per usable kWh of capacity, with these two technologies being the lowest cost in 2050. For the class 8 day cab tractor, the HEV and ICE vehicle begin as the lowest cost powertrains, and the 250-mile BEV reduces in cost from the most expensive to the least expensive by 2030.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Storage Futures Study: Storage Technology Modeling Input Data Report

The Storage Futures Study (SFS) is a multiyear research project to explore the role and impact of energy storage in the evolving electricity sector of the United States. The SFS is designed to examine the potential impact of energy storage technology advancement on the deployment of utility-scale storage and the adoption of distributed storage, and the implications for future power system infrastructure investment and operations. This specific report synthesizes current and projected cost performance assumptions along with location availability for storage technologies through 2050 that will be used in scenario analysis for the SFS at both the bulk power and distribution system scales. For comparison and context, this report also presents a synthesis of current cost and performance characteristics of energy storage technologies for storage durations ranging from minutes to months and including mechanical, thermal, and electrochemical storage technologies for the electricity sector. This information is intended to cover a broad range of storage technologies that are currently receiving significant attention from the investment community as well as in the media. In the report, we emphasize that energy storage technologies must be described in terms of both their power (kilowatts [kW]) capacity and energy (kilowatt-hours [kWh]) capacity to assess their costs and potential use cases.

24 POWER TRANSMISSION AND DISTRIBUTION↗