Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “isolation cooling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Vibrational Spectroscopy at Cryogenic Temperatures: From the Laboratory to the Ends of the Universe

Polycyclic aromatic compounds (PAC) have been the subject of astrophysical interest for nearly two decades. Indeed, there is now evidence that these compounds are among the most abundant interstellar molecules, comprising perhaps 10 - 30% of all the carbon in our galaxy. Ranging in size from as few as 20 to as many as hundreds or thousands of carbon atoms, these molecules are enormous by interstellar standards and impact a wide range of astrophysical phenomena including: the near- and mid-infrared emission spectrum of a wide range of astronomical objects; the ultraviolet/visible/near-infrared absorption of the diffuse medium that permeates our galaxy; and the heating and cooling mechanisms of interstellar clouds. Nevertheless, until recently a lack of laboratory spectroscopic data on PAC under astrophysically relevant conditions (i.e. isolated, ionized molecules; ionized molecular clusters, etc.) has hindered critical evaluation and extension of this model. Fortunately, the last decade has seen an explosion of experimental and theoretical techniques aimed specifically at addressing these issues. Here, we begin with a brief review of the evidence for the existence and abundance of interstellar PAC. From there, we move on to an overview of the general spectroscopic characteristics of the range of isolated, neutral and ionized PAC that we have studied over the last decade. Finally, we will conclude with a consideration of the astrophysical implications and applications of interstellar PAC. Our discussion will revolve primarily around the observed interstellar infrared emission spectra and the ability of the laboratory spectra of varying combinations of PAC to accommodate both the global appearance and the region-to-region variability of this emission. Careful models based on sound laboratory spectroscopic data such as these now have the potential to provide insight into the structure, abundance, and ionization state of the interstellar PAC population. That, in turn, will provide direct insight into the processes of carbon nucleation, growth and evolution as matter is processed through the interstellar medium.

Hudgins, Douglas M.↗

Inadvertent actuation block valve for a small modular nuclear reactor

An inadvertent actuation block valve includes inlet and outlet orifices being in selective fluid communication via a chamber. A disc is disposed within the chamber and a bellows is configured to contract at a predetermined pressure differential between reactor fluid entering a reference pressure orifice and control fluid entering the inlet orifice. When the bellows contracts, the disc engages the outlet orifice and isolates fluid communication between the inlet and outlet orifices. The inadvertent actuation block valve prevents inadvertent opening of an emergency core cooling valve when a reactor is at operating pressure that is above the predetermined set pressure range. The inadvertent actuation block valve permits the emergency cooling valves to open and to remain open when reactor pressure is below the predetermined set pressure range. The inadvertent actuation block valve does not impede long term emergency cooling that occurs when the reactor is at low pressure.

O'Brien, Hugh S.↗

Experimental and Computational Investigation of Shaped Film Cooling Holes Designed to Minimize Inlet Separation

Abstract Film cooling is used to protect turbine components from the extreme temperatures by ejecting coolant through arrays of holes to create an air buffer from the hot combustion gases. Limitations in traditional machining meant film cooling holes universally have sharp inlets, which create separation regions at the hole entrance. The present study uses experimental and computational data to show that these inlet separation are a major cause of performance variation in crossflow fed film cooling holes. Three-hole designs were experimentally tested by independently varying the coolant velocity ratio (VR) and the coolant channel velocity ratio (VRc) to isolate the effects of crossflow on hole performance. Leveraging additive manufacturing (AM) technologies, the addition of a 0.25D radius fillet to the inlet of a 7-7-7 shaped hole is shown to significantly improve diffuser usage and significantly reduce variation in performance with VRc. A second AM design used a very large radius of curvature inlet to reduce biasing caused by the inlet crossflow. Experiments showed that this “swept” hole design did minimize biasing of the coolant flow to one side of the shaped hole, and it significantly reduced variations due to varying VRc. RANS simulations at six VR and three VRc conditions were made for each geometry to better understand how the new geometries changed the velocity field within the hole. The sharp and rounded inlets were seen to have very similar tangential velocity fields and jet biasing. Both AM inlets created more uniform, slower velocity fields entering the diffuser. The results of this article indicate that large improvements in film cooling performance can be found by leveraging AM technology.

Engineering↗

Measurement and analysis of cryogenic sapphire dielectric resonators and DROs

Presented are the experimental and computational results of a study on a new kind of dielectric resonator oscillator (DRO). It consists of a cooled, cylindrically symmetric sapphire resonator surrounded by a metallic shield and is capable of higher Q's than any other dielectric resonator. Isolation of fields to the sapphire by the special nature of the electromagnetic mode allows the very low loss of the sapphire itself to be expressed. Calculations show that the plethora of modes in such resonators can be effectively reduced through the use of a ring resonator with appropriate dimensions. Experimental results show Q's ranging from 3 x 10 to the 8th at 77 K to 10 to the 9th at 4.2 K. Performance is estimated for several types of DROs incorporating these resonators. Phase noise reductions in X-band sources are indicated at values substantially lower than those previously available.

Dick, G. J.↗

Simulations of the supernova-dominated interstellar medium in disk galaxies

A three-dimensional simulation of the evolution of an SNR-dominated ISM from an initially homogeneous, uniform substrate is presented. Systems with only bremsstrahlung cooling are compared with those cooled by radiation from metals. This distinction translates into a size difference in the resulting SNRs, and thus in the ability of isolated SNRs to affect the evolution of the galactic ecosystem. At a given SN rate, correlating the SNe decreases the global evolution of the galaxy if the SNRs individually can affect the system. It is shown that, when the density of the ISM varies widely, the N(R) test can give the reverse of standard expectations. It is shown that strong SNRs can impede interstellar tunnel production because of their ability to transport material and fill a previously evacuated volume, and that cloud size affects the final picture of the system.

Cioffi, Denis F.↗

Development of Ulta-Efficient Electric Motors

Electric motors utilize a large amount of electrical energy in utility and industrial applications. Electric motors constructed with high temperature superconducting (HTS) materials have the potential to dramatically reduce electric motor size and losses. HTS motors are best suited for large motor applications at ratings above 1000 horsepower (hp), where the energy savings from the efficiency improvement can overcome the additional power required to keep the superconductors on the rotor cooled. Large HTS based motors are expected to be half the volume and have half the losses of conventional induction motors of the same rating. For a 5000 hp industrial motor, this energy savings can result in $50,000 in operating cost savings over the course of a single year of operation. Since large horsepower motors utilize (or convert) about 30% of the electrical power generated in the United States and about 70% of large motors are candidates for replacement by HTS motors, the annual energy savings potential through the utilization of HTS motors can be up to $1 Billion in the United States alone. Research in the application of HTS materials to electric motors has lead to a number of HTS motor prototypes yet no industrial HTS motor product has yet been introduced. These motor demonstrations have been synchronous motors with HTS field windings, on the rotor. Figure 1-1 shows a solid model rendering of this type of motor. The rotor winding is made with HTS coils that are held at cryogenic temperature by introducing cooling fluid from the cryocooler to the rotor through a transfer coupling. The stator winding is made of copper wire. The HTS winding is thermally isolated from the warm armature and motor shafts by a vacuum insulation space and through the use of composite torque tubes. The stator in Figure 1-1 is an air core stator in that the stator teeth and a small part of the yoke is made up of nonmagnetic material so the magnetic fields distribute themselves as if in air. Between the HTS field winding and the physical air gap is a series of concentric cylinders that act as vacuum insulation space walls as well as conducting paths for induced currents to flow in order to shield the HTS winding and the rotor cold space from time dependent fields. These time dependent fields may be caused by rotor hunting, during a change in motor load, or by non-fundamental component voltages and currents applied by the inverter. These motors are variable speed controlled by the inverter. Common large motor utility and industrial applications are pump and fan drives that are best suited by a variable speed motor. Inverter control of the HTS motor eliminates the need to design the rotor for line starting, which would dump a large amount of heat into the rotor that would then heavily tax the cryogenic cooling system. The field winding is fed by a brushless exciter that provides DC current to the HTS rotor winding. The stator winding is air or water cooled. Technical and commercial hurdles to industrial HTS motor product introduction and customer acceptance include (1) the high cost of HTS wire and the cryogenic cooling system components, (2) customer concerns about reliability of HTS motors, and (3) the ability to attain the loss reduction potential of large HTS motors. Reliance Electric has demonstrated a number of HTS based electric motors up to a 1000 hp, variable speed synchronous motor with an HTS field winding in the year 2000. In 2001 this motor was tested to 1600 hp with a sinusoidal (constant frequency) supply. Figure 1-2 shows the HTS motor on the dynamometer test stand in the Reliance Electric test lab. The extensive test program of the 1000 hp motor successfully demonstrated the technical feasibility of large HTS motors and the basic technologies involved, however the test results did indicate the need for design refinements. In addition, test results served to identify other more fundamental critical technology issues, and revealed the need to continue research efforts in order to improve future HTS motor first cost, reliability, and performance. The lessons learned from the development and testing of the 1000 hp motor were the basis for the tasks proposed for the project that is being described in this final report. These eight tasks and the technology and commercial issues they address are listed in Table 1-1.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Split-Stirling, linear-resonant, cryogenic refrigerators for detector cooling

For the past decade, military IR systems have preferred to see cryogenic coolers provided as split units; separating the functions of compressor and cold-end for system packaging and vibration isolation reasons. A family of split-cycle coolers designed for long MTBF and in the final stages of development is the focus of the discussion. Their technological evolution, from multi-year-MTBF satellite system Stirling coolers developed in the U.S., and the UA 7011 cooler (the first all-linear, military, production cooler) developed in Holland, is explained. Two new split-cycle machines are discussed. They provided 1/4 watt and 1 watt (nominal capacity) at 80 K and 85 K respectively. These linear-resonant, free-displacer Stirling coolers are designed for thousands of hours of service-free operation. They are designed to be compatible with standard U.S. 60 element and 120/180 element detector/dewars, respectively.

Lehrfeld, D.↗

Thermal links for the implementation of an optical refrigerator

Optical refrigeration has been demonstrated by several groups of researchers, but the cooling elements have not been thermally linked to realistic heat loads in ways that achieve the desired temperatures. The ideal thermal link will have minimal surface area, provide complete optical isolation for the load, and possess high thermal conductivity. We have designed thermal links that minimize the absorption of fluoresced photons by the heat load using multiple mirrors and geometric shapes including a hemisphere, a kinked waveguide, and a tapered waveguide. While total link performance is dependent on additional factors, we have observed net transmission of photons with the tapered link as low as 0.04%. Our optical tests have been performed with a surrogate source that operates at 625 nm and mimics the angular distribution of light emitted from the cooling element of the Los Alamos solid state optical refrigerator. We have confirmed the optical performance of our various link geometries with computer simulations using CODE V optical modeling software. In addition we have used the thermal modeling tool in COMSOL MULTIPHYSICS to investigate other heating factors that affect the thermal performance of the optical refrigerator. Assuming an ideal cooling element and a nonabsorptive dielectric trapping mirror, the three dominant heating factors are (1) absorption of fluoresced photons transmitted through the thermal link, (2) blackbody radiation from the surrounding environment, and (3) conductive heat transfer through mechanical supports. Modeling results show that a 1 cm{sup 3} load can be chilled to 107 K with a 100 W pump laser. We have used the simulated steady-state cooling temperatures of the heat load to compare link designs and system configurations.

47 OTHER INSTRUMENTATION↗

Micro-scale heat-exchangers for Joule-Thomson cooling.

This project focused on developing a micro-scale counter flow heat exchangers for Joule-Thomson cooling with the potential for both chip and wafer scale integration. This project is differentiated from previous work by focusing on planar, thin film micromachining instead of bulk materials. A process will be developed for fabricating all the devices mentioned above, allowing for highly integrated micro heat exchangers. The use of thin film dielectrics provides thermal isolation, increasing efficiency of the coolers compared to designs based on bulk materials, and it will allow for wafer-scale fabrication and integration. The process is intended to implement a CFHX as part of a Joule-Thomson cooling system for applications with heat loads less than 1mW. This report presents simulation results and investigation of a fabrication process for such devices.

Gross, Andrew John↗

Variable-temperature cryogenic trap for the separation of gas mixtures

The paper describes a continuous variable-temperature U-shaped cold trap which can both purify vacuum-line combustion products for subsequent stable isotopic analysis and isolate the methane and ethane constituents of natural gases. The canister containing the trap is submerged in liquid nitrogen, and, as the gas cools, the gas mixture components condense sequentially according to their relative vapor pressures. After the about 12 min required for the bottom of the trap to reach the liquid-nitrogen temperature, passage of electric current through the resistance wire wrapped around the tubing covering the U-trap permits distillation of successive gas components at optimal temperatures. Data on the separation achieved for two mixtures, the first being typical vacuum-line combustion products of geochemical samples such as rocks and the second being natural gas, are presented, and the thermal behavior and power consumption are reported.

Des Marais, D. J.↗

Evolution of the 1991-1992 Arctic vortex and comparison with the Geophysical Fluid Dynamics Laboratory SKYHI general circulation model

Nitrous oxide (N2O) measured on board the ER-2 aircraft during the Airborne Arctic Stratospheric Expedition 2 (AASE 2) has been used to monitor descent of air inside the Arctic vortex between October 1991 and March 1992. Monthly mean N2O fields are calculated from the flight data and then compared with mean fields calculated from the high-resolution Geophysical Fluid Dynamics Laboratory general circulation model SKYHI in order to evaluate the model's simulation of the polar vortex. From late fall through winter the model vortex evolves in much the same way as the 1991-1992 vortex, with N2O gradients at the edge becoming progressively steeper. The October to March trends in N2O profiles inside the vortex are used to verify daily net heating rates in the vortex that were computed from clear sky radiative heating rates and National Meteorological Center temperature observations. The computed heating rates successfully estimate the descent of vortex air from December through February but suggest that before December, air at high latitudes may not be isolated from the midlatitudes. SKYHI heating rates are in good agreement with the computed rates but tend to be slightly higher (i.e., less cooling) due to meteorological differences between SKYHI and the 1991-1992 winter. Three ER-2 flights measured N2O just north of the subtropical jet. These low-midlatitude profiles show only slight differences from the high-midlatitude profiles (45 deg - 60 deg N), indicating strong meridional mixing in the midlatitude 'surf zone.' Mean midwinter N2O profiles inside and outside the vortex calculated from AASE 2 data are shown to be nearly identical to 1989 AASE profiles, pointing to the N2O/potential temperature relationship as an excellent marker for vortex air.

Strahan, S. E.↗

The International Space Station 2B Photovoltaic Thermal Control System (PVTCS) Leak: An Operational History

As early as 2004, the Photovoltaic Thermal Control System (PVTCS) for the International Space Station's 2B electrical power channel began slowly leaking ammonia overboard. Initially, the operations strategy was "feed the leak," a strategy successfully put into action via Extra Vehicular Activity (EVA) during the STS-134 Space Shuttle mission. This recharge was to have allowed for continued power channel operation into 2014 or 2015, at which point another EVA would have been required. In mid-2012, the leak rate increased from 1.5lbm/year to approximately 5lbm/year. As a result, an EVA was planned and executed within a 5 week timeframe to drastically alter the architecture of the PVTCS via connection to an adjacent dormant thermal control system. This EVA, US EVA 20, was successfully executed on November 1, 2012 and left the 2B PVTCS in a configuration where the system was now being adequately cooled via a different radiator than what the system was designed to utilize. Data monitoring over the next several months showed that the isolated radiator had not been leaking, and the system itself continued to leak steadily until May 9th, 2013. It was on this day that the ISS crew noticed the visible presence of ammonia crystals escaping from the 2B channel's truss segment, signifying a rapid acceleration of the leak from 5lbm/year to 5lbm/day. Within 48 hours of the crew noticing the leak, US EVA 21 was in progress to replace the coolant pump - the only remaining replaceable leak source. This was successful, and telemetry monitoring has shown that indeed the coolant pump was the leak source and was thus isolated from the running 2B PVTCS. This paper will explore the management of the 2B PVTCS leak from the operations perspective.

Vareha, Anthony N.↗

Use of Mechanical Heat Switch to Speed up TVAC Transitions on Flight Hardware Below 200K

Spaceflight hardware that operates at temperatures well below room temperature usually require being well isolated from their warmer environment in order to manage thermal parasitics adequately. This is especially true for spaceflight systems that rely on passive cooling such as a radiator. During ground testing, this design configuration can be problematic for TVAC cycling between operational temperature extremes, since the hardware temperatures may move extremely slowly and lengthen the duration of an already expensive and heavily staffed system-level TVAC campaign. One of the challenges of using an external means of speeding up temperature transitions is that a TVAC campaign usually also requires the simulation of flight-like environments to validate the design, and introducing a test feature to speed up transitions can disrupt the system such that flight-like environments are not achievable. Such an approach was used for the L’Ralph instrument level TVAC test. L’Ralph is a passively cooled instrument on the Lucy mission with planned flyby’s of the Trojan asteroids around 5.5 AU. The optics and visible detector are cooled below 190K, and the IR detector is cooled below 110K. During instrument TVAC qualification testing, a mechanical motor-controlled heat switch uses clamping pressure via a vise-grip mechanism to achieve faster temperature transitions by increasing the conduction to a cold sink. The heat switch system then disengages and employs zero-Q controls to achieve flight-like thermal environments for thermal balance plateaus. Results from stand-alone testing of the heat switch are discussed, including correlated on/off ratios and the expected conductance across its operational temperature range. Test data from an instrument level TVAC that successfully utilized the heat switch are also shown.

Daniel G Bae↗

Using Digital Image Correlation for Material Testing at Cryogenic Temperatures

Recent efforts were made to parametrize an aluminum alloy at cryogenic temperatures to calibrate finite element models simulating material deformation. Digital image correlation (DIC) was used to measure material properties using front/back strains of specimens during tensile tests. Data acquired from DIC was compared to physical extensometer measurements. Two camera pairs (front and back) were mounted via aluminum extrusion to the exterior of an environmental chamber of a hydraulic test stand. Images were taken through single-pane optical glass windows of the environment chamber. Positive pressure bags encased the cameras, attaching to the perimeter of the glass to keep out moisture and prevent windows from frosting. Figure 1 shows the environmental setup and the camera setup during cryogenic testing. Some of the challenges during testing at cryogenic temperatures include the gaseous flow of liquid nitrogen in the optical path of the mounted cameras, frost buildup on the windows as seen in Figure 1b, and frost on the test coupon. The temperature gradient present during the introduction of liquid nitrogen into the chamber can increase the projection error of images captured of the specimen. Figure 2 shows the estimated projection error from DIC as a function of temperature during the cool down process. This presentation addresses some of the concerns and observations when using DIC for testing at cryogenic temperatures using methods of isolated camera system and techniques for maintaining the glass panel clear from frost.

Joseph Cochran↗

Simulating the Effect of Fracture Connectivity on Repository Performance with GDSA Framework - 18589

This work examines the possible migration of radionuclides from a deep geologic nuclear waste repository sited in fractured crystalline host rock. The key safety concern is the potential effect on waste isolation of the inter-connectivity of the fracture network, which is primarily established by the temporal evolution of the temperature and stress fields at the time of original rock intrusion and cooling. Two end members are considered in these simulations, one with a high degree of connectivity to the biosphere, such that advective transport through the fracture and fault network controls radionuclide migration, and the other with a low degree of connectivity, such that slow diffusive transport through the crystalline rock matrix is the controlling process for radionuclide migration to the biosphere. Both end members have several areally extensive, high-transmissivity deformation zones, whose distance to the repository is an important factor for waste isolation capability. Uncertainties in fracture properties (transmissivity, orientation, radius) and fracture distribution also give rise to uncertainty in waste isolation capability (i.e., the overall connectivity of the repository with the surface biosphere). These types of natural system uncertainties are generally present in any geologic site-characterization program and thus represent an important factor in assessing repository performance in hard rock environments. The waste considered in these simulations are spent fuel rod assemblies from the U.S. commercial nuclear reactor fleet. Thermal output of the waste must be considered in the simulations and can influence the rate and timing of waste package failure, waste form degradation, and fluid flux due to thermal expansion around the repository horizon. To achieve a high-fidelity representation of radionuclide transport in fractures and rock matrix, combined with thermal energy transport and fluid flow in fractures and matrix, the mathematical model is solved numerically in a parallel high-performance computing (HPC) environment on a finite volume unstructured grid consisting of approximately 5 million cells, using Geologic Disposal Safety Assessment (GDSA) Framework (https://pa.sandia.gov), an open-source performance assessment tool for deep underground disposal of nuclear waste. GDSA Framework uses PFLOTRAN to solve the balance equations on a three-dimensional grid with heterogeneous properties, using multiple processors in a parallel configuration based on domain decomposition. The fracture networks in these simulations are originally generated as discrete fracture networks (DFNs), which are sets of two-dimensional planes distributed in a three-dimensional domain. The method used in GDSA Framework maps the stochastically generated DFN to an equivalent continuous porous medium (ECPM) domain that allows for the simulation of coupled heat flow, fluid flow, and radionuclide transport, including heat conduction through the matrix of the fractured rock, which is a process not easily modeled in a DFN representation. Computational efficiency is also greatly enhanced using the ECPM method, allowing for a realistic representation and analysis of uncertainties in a multi-realization performance assessment of a deep geologic repository. The effect of fracture connectivity on the waste isolation safety function, as brought to light by these GDSA Framework simulations, points to the importance of including a realistic representation of uncertainties in fracture properties and distribution (effectively, uncertainty in spatial heterogeneity) in repository safety assessment simulations. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Thermal Evolution of Isolated Neutron Stars: Pairing, Pairing, and Pairing

The thermal evolution of young isolated neutron stars is driven by neutrino emission from matter at the highest densities reached in their inner core. As such, these objects are direct probes of the structure of matter at supranuclear density. However, pairing of the neutrino emitting baryons, or quarks, can significantly alter their emission efficiency and the predicted thermal evolution is very sensitive to assumptions about gap size(s). After a brief description of these physical processes, I compare with present observational data models of cooling neutron stars driven by slow or fast neutrino emission. Depending on the assumed size of the neutron {sup 3}P{sub 2}-{sup 3}F{sub 2} gap, a minimal model of neutron stars can accommodate all present data, with the exception of the cold pulsar J0007.0+7303 in the supernova remnant CTA 1. However, in case this gap is vanishingly small or very large, the estimated surface temperatures of more than a half of the observed young cooling neutron stars would imply the intervention of some form of enhanced neutrino emission. Unfortunately, the present uncertainty on the size of the neutron {sup 3}P{sub 2}-{sup 3}F{sub 2} gap precludes us to draw any definitive conclusion about the state of dense matter from the sole study of isolated neutron stars.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A cryogen-free low temperature scanning tunneling microscope capable of inelastic electron tunneling spectroscopy

The design and performance of a cryogen-free low temperature scanning tunneling microscope (STM) housed in ultrahigh vacuum (UHV) are reported. The cryogen-free design was done by directly integrating a Gifford-McMahon cycle cryocooler to a Besocke-type STM, and the vibration isolation was achieved by using a two-stage rubber bellow between the cryocooler and a UHV-STM interface with helium exchange gas cooling. A base temperature of 15 K at the STM was achieved, with a possibility to further decrease by using a cryocooler with higher cooling power and adding additional low temperature stage under the exchange gas interface. Atomically sharp STM images and high resolution dI/dV spectra on various samples were demonstrated. Furthermore, we reported the inelastic tunneling spectroscopy on a single carbon monoxide molecule adsorbed on Ag(110) surface with a cryogen-free STM for the first time. Being totally cryogen-free, the system not only saves the running cost significantly but also enables uninterrupted data acquisitions and variable temperature measurements with much ease. In addition, the system is capable of coupling light to the STM junction by a pair of lens inside the UHV chamber. We expect that these enhanced capabilities could further broaden our views to the atomic-scale world.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Solid-Liquid Interface Characterization Hardware: Advanced Technology Development (ATD)

This ATD has the goal of enabling the integration of three separate measurement techniques to characterize the solid-liquid interface of directionally solidified materials in real-time. Arrays of film-based metal thermocouple elements are under development along with compact Seebeck furnaces suitable for interfacing with separately developed X-ray Transmission Microscopes. Results of applying film arrays to furnace profiling are shown, demonstrating their ability to identify a previously undetected hardware flaw in the development of a second-generation compact furnace. Results of real-time furnace profiling also confirmed that the compact furnace design effectively isolates the temperature profiles in two halves of the furnace, a necessary feature. This isolation had only been inferred previously from the characteristics of Seebeck data reported. Results from a 24-thermocouple array successfully monitoring heating and isothermal cooling of a tin sample are shown. The importance of non-intrusion by the arrays, as well as furnace design, on the profiling of temperature gradients is illustrated with example measurements. Further developments underway for effectively combining all three measurements are assessed in terms of improved x-ray transmission, increased magnification, integral arrays with minimum intrusion, integral scales for velocity measurements and other features being incorporated into the third generation Seebeck furnace under construction.

Peters, Palmer N.↗