Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “interferometers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

THE KECK INTERFEROMETER NULLER

The Keck Interferometer Nuller (KIN), the first operational separated-aperture infrared nulling interferometer, was designed to null the mid-infrared emission from nearby stars so as to ease the measurement of faint circumstellar emission. This paper describes the basis of the KIN's four-beam, two-stage measurement approach and compares it to the simpler case of a two-beam nuller. In the four-beam KIN system, the starlight is first nulled in a pair of nullers operating on parallel 85 m Keck-Keck baselines, after which 'cross-combination' on 4 m baselines across the Keck apertures is used to modulate and detect residual coherent off-axis emission. Comparison to the constructive stellar fringe provides calibration. The response to an extended source is similar in the two cases, except that the four-beam response includes a term due to the visibility of the source on the cross-combiner baseline-a small effect for relatively compact sources. The characteristics of the dominant null depth errors are also compared for the two cases. In the two-beam nuller, instrumental imperfections and asymmetries lead to a series of quadratic, positive-definite null leakage terms. For the four-beam nuller, the leakage is instead a series of correlation cross-terms combining corresponding errors in each of the two nullers, which contribute offsets only to the extent that these errors are correlated on the timescale of the measurement. This four-beam architecture has allowed a significant ({approx}order of magnitude) improvement in mid-infrared long-baseline fringe-visibility accuracies.

79 ASTRONOMY AND ASTROPHYSICS↗

PLATFORM DEFORMATION PHASE CORRECTION FOR THE AMiBA-13 COPLANAR INTERFEROMETER

We present a new way to solve the platform deformation problem of coplanar interferometers. The platform of a coplanar interferometer can be deformed due to driving forces and gravity. A deformed platform will induce extra components into the geometric delay of each baseline and change the phases of observed visibilities. The reconstructed images will also be diluted due to the errors of the phases. The platform deformations of The Yuan-Tseh Lee Array for Microwave Background Anisotropy (AMiBA) were modeled based on photogrammetry data with about 20 mount pointing positions. We then used the differential optical pointing error between two optical telescopes to fit the model parameters in the entire horizontal coordinate space. With the platform deformation model, we can predict the errors of the geometric phase delays due to platform deformation with a given azimuth and elevation of the targets and calibrators. After correcting the phases of the radio point sources in the AMiBA interferometric data, we recover 50%-70% flux loss due to phase errors. This allows us to restore more than 90% of a source flux. The method outlined in this work is not only applicable to the correction of deformation for other coplanar telescopes but also to single-dish telescopes with deformation problems. This work also forms the basis of the upcoming science results of AMiBA-13.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measuring the cosmological 21 cm monopole with an interferometer

A measurement of the cosmological 21 cm signal remains a promising but as-of-yet unattained ambition of radio astronomy. A positive detection would provide direct observations of key unexplored epochs of our cosmic history, including the cosmic dark ages and reionization. In this paper, we concentrate on measurements of the spatial monopole of the 21 cm brightness temperature as a function of redshift (the “global signal”). Most global experiments to date have been single-element experiments. In this paper, we show how an interferometer can be designed to be sensitive to the monopole mode of the sky, thus providing an alternate approach to accessing the global signature. We provide simple rules of thumb for designing a global signal interferometer and use numerical simulations to show that a modest array of tightly packed antenna elements with moderately sized primary beams (FWHM of ∼40{sup ∘}) can compete with typical single-element experiments in their ability to constrain phenomenological parameters pertaining to reionization and the pre-reionization era. We also provide a general data analysis framework for extracting the global signal from interferometric measurements (with analysis of single-element experiments arising as a special case) and discuss trade-offs with various data analysis choices. Given that interferometric measurements are able to avoid a number of systematics inherent in single-element experiments, our results suggest that interferometry ought to be explored as a complementary way to probe the global signal.

79 ASTRONOMY AND ASTROPHYSICS↗

Comparison of machine learning systems trained to detect Alfvén eigenmodes using the CO 2 interferometer on DIII-D

Abstract A Machine-Learning (ML) based detection scheme that automatically detects Alfvén Eigenmodes (AE) in a labelled DIII-D database is presented here. Controlling AEs is important for the success of planned burning plasma devices such as ITER, since resonant fast ions can drive AEs unstable and degrade the performance of the plasma or damage the first walls of the machine vessel. Artificial Intelligence could be useful for real-time detection and control of AEs in steady-state plasma scenarios by implementing ML-based models into control algorithms that drive actuators for mitigation of AE impacts. Thus, the objective is to compare differences in performance between using two different recurrent neural network systems (Reservoir Computing Network and Long Short Term Memory Network) and two different representations of the C O 2 phase data (simple and crosspower spectrograms). All C O 2 interferometer chords are used to train both models, but only one is processed during each training step. The results from the model and data comparison show higher performance for the RCN model (True Positive Rate = 90% and False Positive Rate = 14%), and that using simple magnitude spectrograms is sufficient to detect AEs. Also, the vertical C O 2 interferometer chord passing near the center is better for ML-based detection of AEs.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Thermal calcium atom interferometer with a phase resolution of a few milliradians based on a narrow-linewidth diode laser

A symmetrical atom interferometer with a thermal calcium atom beam has been developed using a narrow linewidth diode laser stabilized to the resonance of a high-finesse cavity. The linewidth of the diode laser was estimated to be less than 1 Hz relative to the cavity resonance in noise measurement over the range of 100 Hz to 1 MHz, and the phase instability of the interference fringes obtained from the Allan deviation was improved to 2 mrad at an integration time of 300 s. Using this atom interferometer, the ac Stark phase shift between the {sup 1}S{sub 0} and {sup 3}P{sub 1} states of a Ca atom was measured as a function of a laser power near the resonance of the {sup 1}S{sub 0}-{sup 1} P{sub 1} transition at a wavelength of 423 nm. The decay rate of the {sup 1}P{sub 1} state was determined to be {gamma}=1.91(33)x10{sup 8} s{sup -1}.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Analysis of a free oscillation atom interferometer

We analyze a Bose-Einstein condensate (BEC)-based free oscillation atom Michelson interferometer in a weakly confining harmonic magnetic trap. A BEC at the center of the trap is split into two harmonics by a laser standing wave. The harmonics move in opposite directions with equal speeds and turn back under the influence of the trapping potential at their classical turning points. The harmonics are allowed to pass through each other and a recombination pulse is applied when they overlap at the end of a cycle after they return for the second time. We derive an expression for the contrast of the interferometric fringes and obtain the fundamental limit of performance of the interferometer in the parameter space.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Manipulation of the resonance interaction in Mach-Zehnder-Fano interferometers

We study tunable interaction of the resonances in the Mach-Zehnder-Fano interferometers (MZFIs). A discrete Mach-Zehnder interferometer (MZI) with balanced arms supports bound states in the continuum. We demonstrate that doping an impurity in conventional MZIs gives rise to robust high-Q Fano resonances with asymmetric line shapes. By means of the modified Fano-Anderson model and the scattering-matrix approach, we show that the transmission and the intensity spectra of the whole system are very sensitive to both the location and the strength of the impurity. The side-coupled Fano defects induce an interaction with different eigenmodes of the pure MZI loop. We explore this interaction by tuning the parameters of the Fano defects. The observed resonance interaction can be attributed to the Fano-Feshbach resonance. We further provide with a particular physical example of photonic crystal circuit the applicability of our concept.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Prototyping method for Bragg-type atom interferometers

We present a method for rapid modeling of new Bragg ultracold atom-interferometer (AI) designs useful for assessing the performance of such interferometers. The method simulates the overall effect on the condensate wave function in a given AI design using two separate elements. These are (1) modeling the effect of a Bragg pulse on the wave function and (2) approximating the evolution of the wave function during the intervals between the pulses. The actual sequence of these pulses and intervals is then followed to determine the approximate final wave function from which the interference pattern can be calculated. The exact evolution between pulses is assumed to be governed by the Gross-Pitaevskii (GP) equation whose solution is approximated using a Lagrangian variational method to facilitate rapid estimation of performance. The method presented here is an extension of an earlier one that was used to analyze the results of an experiment [J. E. Simsarian et al., Phys. Rev. Lett. 85, 2040 (2000)], where the phase of a Bose-Einstein condensate was measured using a Mach-Zehnder-type Bragg AI. We have developed both 1D and 3D versions of this method and we have determined their validity by comparing their predicted interference patterns with those obtained by numerical integration of the 1D GP equation and with the results of the above experiment. We find excellent agreement between the 1D interference patterns predicted by this method and those found by the GP equation. We show that we can reproduce all of the results of that experiment without recourse to an ad hoc velocity-kick correction needed by the earlier method, including some experimental results that the earlier model did not predict. We also found that this method provides estimates of 1D interference patterns at least four orders-of-magnitude faster than direct numerical solution of the 1D GP equation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Calibration of the Modulation Transfer Function of Surface Profilometers with Binary Pseudorandom Test Standards: Expanding the Application Range to Fizeau Interferometers and Electron Microscopes

A modulation transfer function (MTF) calibration method based on binary pseudorandom (BPR) gratings and arrays has been proven to be an effective MTF calibration method for interferometric microscopes and a scatterometer. Here we report on a further expansion of the application range of the method. We describe the MTF calibration of a 6 in. phase shifting Fizeau interferometer. Beyond providing a direct measurement of the interferometer's MTF, tests with a BPR array surface have revealed an asymmetry in the instrument's data processing algorithm that fundamentally limits its bandwidth. Moreover, the tests have illustrated the effects of the instrument's detrending and filtering procedures on power spectral density measurements. The details of the development of a BPR test sample suitable for calibration of scanning and transmission electron microscopes are also presented. Such a test sample is realized as a multilayer structure with the layer thicknesses of two materials corresponding to the BPR sequence. The investigations confirm the universal character of the method that makes it applicable to a large variety of metrology instrumentation with spatial wavelength bandwidths from a few nanometers to hundreds of millimeters.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High energy x-ray phase contrast CT using glancing-angle grating interferometers

Purpose: The authors present initial progress toward a clinically compatible x-ray phase contrast CT system, using glancing-angle x-ray grating interferometry to provide high contrast soft tissue images at estimated by computer simulation dose levels comparable to conventional absorption based CT. Methods: DPC-CT scans of a joint phantom and of soft tissues were performed in order to answer several important questions from a clinical setup point of view. A comparison between high and low fringe visibility systems is presented. The standard phase stepping method was compared with sliding window interlaced scanning. Using estimated dose values obtained with a Monte-Carlo code the authors studied the dependence of the phase image contrast on exposure time and dose. Results: Using a glancing angle interferometer at high x-ray energy (∼45 keV mean value) in combination with a conventional x-ray tube the authors achieved fringe visibility values of nearly 50%, never reported before. High fringe visibility is shown to be an indispensable parameter for a potential clinical scanner. Sliding window interlaced scanning proved to have higher SNRs and CNRs in a region of interest and to also be a crucial part of a low dose CT system. DPC-CT images of a soft tissue phantom at exposures in the range typical for absorption based CT of musculoskeletal extremities were obtained. Assuming a human knee as the CT target, good soft tissue phase contrast could be obtained at an estimated absorbed dose level around 8 mGy, similar to conventional CT. Conclusions: DPC-CT with glancing-angle interferometers provides improved soft tissue contrast over absorption CT even at clinically compatible dose levels (estimated by a Monte-Carlo computer simulation). Further steps in image processing, data reconstruction, and spectral matching could make the technique fully clinically compatible. Nevertheless, due to its increased scan time and complexity the technique should be thought of not as replacing, but as complimentary to conventional CT, to be used in specific applications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Measurement Error of Interferometers with Diffraction Reference Wave

An experimental setup and results on aberration of sources of a reference spherical wave (SRSW) based on a single-mode optical fiber with a subwavelength output aperture obtained with the aid of an optical part of recording system (OPRS) are presented. SRSW and OPRS are developed for referenceless interferometer with diffraction reference wave. Methods for minimization of the measurement error are proposed. The SRSW and OPRS provide subnanometer measurement accuracy for optics. An increase in the measurement accuracy of the interferometer to a picometer level is discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Testing a Model of Planck-Scale Quantum Geometry With Broadband Correlation of Colocated 40m Interferometers

The Holometer is designed to test for a Planck diffractive-scaling uncertainty in long-baseline position measurements due to an underlying noncommutative geometry normalized to relate Black hole entropy bounds of the Holographic principle to the now-finite number of position states. The experiment overlaps two independent 40 meter optical Michelson interferometers to detect the proposed uncertainty as a common broadband length fluctuation. 150 hours of instrument cross-correlation data are analyzed to test the prediction of a correlated noise magnitude of $7\times10^{−21}$ m/$\sqrt{\rm Hz}$ with an effective bandwidth of 750kHz. The interferometers each have a quantum-limited sensitivity of $2.5\times 10^{−18}$ m/$\sqrt{\rm Hz}$, but their correlation with a time-bandwidth product of $4\times 10^{11}$ digs between the noise floors in search for the covarying geometric jitter. The data presents an exclusion of 5 standard deviations for the tested model. This exclusion is defended through analysis of the calibration methods for the instrument as well as further sub shot noise characterization of the optical systems to limit spurious background-correlations from undermining the signal.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A New Simple Interferometer for Obtaining Quantitatively Evaluable Flow Patterns

The method described in the present report makes it possible to obtain interferometer records with the aid of any one of the available Schlieren optics by the addition of very simple expedients, which fundamentally need not to be inferior to those obtained by other methods, such as the Mach-Zehnder interferometer, for example. The method is based on the fundamental concept of the phase-contrast process developed by Zernike, but which in principle has been enlarged to such an extent that it practically represents an independent interference method for general applications. Moreover, the method offers the possibility, in case of necessity, of superposing any apparent wedge field on the density field to be gauged. The theory is explained on a purely physical basis and illustrated and proved by experimental data. A number of typical cases are cited and some quantitative results reported.

INSTRUMENTS - INTERFEROMETERS↗

Imaging interferometer using dual broadband quantum well infrared photodetectors

The Jet Propulsion Laboratory is developing a new imaging interferometer that has double the efficiency of conventional interferometers and only a fraction of the mass and volume. The project is being funded as part of the Defense Advanced Research Projects Agency (DARPA) Photonic Wavelength And Spatial Signal Processing program (PWASSSP).

IR quantum well interferometer imaging spectromete↗

On the Antenna Pattern of Orbitting Interferometer

We consider the response of an interferometer moving with respect to a fixed reference frame, and derive a simple expression for the beam-pattern factors and the polarization-averaged antenna power pattern...Then, we consider a class of motions where the detector's plane is constrained to move on the surface of a cone of constant aperture; at the same time, the two arms are rotating around a vertical axis...In addition, we consider the case of an Earth-based interferometer...Finally, we discuss LISA's response to circularly polarized sinusoidal waves, coming from a few known binary systems in our Galaxy.

interferometer interferometry antenna motions LISA↗

Mission Analysis for Laser Interferometer Space Antenna (LISA)

The interplanetary orbits of three pairs of spaceprobes carrying laser interferometer antennae are designed such that their miutual distances, i.e., the lengths of the interferometer arms remain nearly constant. The pairs move relative to each other in an equilateral triangle.

LISA interferometry interferometer↗

The Micro Fourier Transform Interferometer (muFTIR) - A New Field Spectrometer for Acquisition of Infrared Data of Natural Surfaces

A lightweight, rugged, high-spectral-resolution interferometer has been built by Designs and Prototypes based on a set of specifications provided by the Jet Propulsion Laboratory and Dr. J. W. Salisbury (Johns Hopkins University). The instrument, the micro Fourier Transform Interferometer (mFTIR), permits the acquisition of infrared spectra of natural surfaces. Such data can be used to validate low and high spectral resolution data acquired remotely from aircraft and spacecraft in the 3-5 mm and 8-14 mm atmospheric window. The instrument has a spectral resolutions of ~6 wavenumbers, weighs 16 kg including batteries and computer, and can be operated easily by two people in the field. Laboratory analysis indicates the instrument is spectrally calibrated to better than 1 wavenumber and the radiometric accuracy is <0.5 K if the radiances from the blackbodies used for calibration bracket the radiance from the sample.

Fourier Interferometer↗