Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “images”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

A coded aperture with sub-mean-free-path thickness for implosion geometry imaging on ICF and IFE experiments

Inertial confinement fusion and inertial fusion energy experiments diagnose the geometry of the fusion region through imaging of the neutrons released through fusion reactions. Pinhole arrays typically used for such imaging require thick substrates to obtain high contrast along with a small pinhole diameter to obtain high resolution capability, resulting in pinholes that have large aspect ratios. This leads to expensive pinhole arrays that have small solid angles and are difficult to align. Here, we propose a coded aperture with scatter and partial attenuation (CASPA) for fusion neutron imaging that relaxes the thick substrate requirement for good image contrast. These coded apertures are expected to scale to larger solid angles and are easier to align without sacrificing imaging resolution or throughput. We use Monte Carlo simulations (Geant4) to explore a coded aperture design to measure neutron implosion asymmetries on fusion experiments at the National Ignition Facility (NIF) and discuss the viability of this technique, matching the current nominal resolution of 10 µm. The results show that a 10 mm thick tungsten CASPA can image NIF implosions with neutron yields above 10 14 with quality comparable to unprocessed data from a current NIF neutron imaging aperture. Furthermore, this CASPA substrate is 20 times thinner than the current aperture arrays for fusion neutron imaging and less than one mean free-path of 14.1 MeV neutrons through the substrate. Since the resolution, solid angle, and throughput are decoupled in coded aperture imaging, the resolution and solid angle achievable with future designs will be limited primarily by manufacturing capability.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

NIR fluorescence lifetime macroscopic imaging with a time-gated SPAD camera

The performance of SwissSPAD2 (SS2), a large scale, widefield time-gated CMOS SPAD imager developed for fluorescence lifetime imaging, has recently been described in the context of visible range and fluorescence lifetime imaging microscopy (FLIM) of dyes with lifetimes in the 2.5 – 4 ns range. Here, we explore its capabilities in the NIR regime relevant for small animal imaging, where its sensitivity is lower and typical NIR fluorescent dye lifetimes are much shorter (1 ns or less). We carry out this study in a simple macroscopic imaging setup based on a compact NIR picosecond pulsed laser, an engineered diffuser-based illumination optics, and NIR optimized imaging lens suitable for well-plate or small animal imaging. Because laser repetition rates can vary between models, but the synchronization signal frequency accepted by SS2 is fixed to 20 MHz, we first checked that a simple frequency-division scheme enables data recording for different laser repetition rates. Next, we acquired data using different time gate widths, including gates with duration longer than the laser period, and analyzed the resulting data using both standard nonlinear least-square fit (NLSF) and phasor analysis. We show that the fixed synchronization rate and large gate widths characterizing SS2 (10 ns and over) are not an obstacle to accurately extracting lifetime in the 1 ns range and to distinguishing between close lifetimes. As a result, SS2 and similar very large gated SPAD imagers appear as a versatile alternative to other widefield time-resolved detectors for NIR fluorescence lifetime imaging, including preclinical molecular applications.

FLIM↗

Gamma ray Imaging Based Methods to Improve the Accuracy of Uranium Holdup Quantification

Deposits in commercial uranium processing facilities of interest to nuclear safeguards are predominantly low enriched uranium (LEU). The shapes and sizes of holdup deposits can vary significantly, thus making it difficult to model the deposits accurately for calibration purposes. This presents a challenge to currently employed methods such as the Generalized Geometry Holdup (GGH) that rely on quantifying 235U mass by simplifying deposit shapes as a point, a line, or an area. In this work, gamma ray imaging using high energy resolution Germanium Gamma Imagers (GeGI™) is employed to determine the distribution of uranium inside the source containment. Two types of imaging methods are employed; coded-aperture imaging and Compton imaging. Gamma-ray emissions seen in different regions of the image are quantified using an inverse gamma-ray transport solver being developed at ORNL. Using measured data, the inverse method will be used to solve for unknown source parameters such as source matrix thickness, density, and attenuation due to container wall and shielding. The intrinsic efficiency of the detector is determined based on a library of built-in response functions and key dimensions of the detector (e.g., thickness and radius of the detector crystal). Measurements are performed in both imaging modalities using uranium sources of well-known masses and enrichments configured inside mocked-up holdup fixtures. Results from the two imaging modalities are intercompared. The paper presents preliminary results of the imaging measurements and the progress made in the computational methods to quantify uranium mass.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Advancing X-ray quantum imaging through Monte-Carlo simulations

Imaging with X-rays poses fundamental limits due to radiation damage of the highly energetic photons. This becomes problematic for sensitive biological systems such as subcellular structures. Lowering the radiation dose, without sacrificing the signal-to-noise ratio, would be desirable for any kind of imaging modalities involving X-rays. To achieve this goal, quantum imaging with entangled X-ray photons constitutes a promising route. Production of biphotons have been demonstrated in the X-ray regime by the process of Spontaneous Parametric Down-Conversion (SPDC). However, compared to SPDC in the regime of visible light, the production rate for X-ray biphotons is extremely low. With the introduction of new high average brightness X-ray sources, such as 4th generation synchrotrons and high repetition rate Free-Electron X-ray Lasers (XFEL), quantum imaging may become practical. We introduce a ray tracing approach using Monte-Carlo sampling, specifically designed for quantum imaging with entangled X-ray photons generated by SPDC. By simulation, the superior image quality of quantum over classical imaging methods is demonstrated using realistic experimental conditions available at high repetition rate XFELs. With these simulations, we can efficiently assist the design of future experiments at beam lines, which can substantially accelerate the advancement of X-ray quantum imaging and reduce costs.

Entangled Photons↗

A New Workflow of X-ray CT Image Processing and Data Analysis of Structural Features in Rock Using Open-Source Software

X-ray computed tomography (CT) images of rock specimens often contain artifacts which must be corrected before scientific analyses are performed. Here, we present a new workflow of automated image processing to utilize poor-quality X-ray CT scan images. The workflow runs on the open-source image analysis software and efficiently separates desired features from low-contrast scanned images. The new workflow is a two-step technique using contrast enhancement and automated feature segmentation to generate noise-free binary images. The results of binary images using the proposed workflow and using a conventional thresholding technique are analyzed to show the quality of the proposed method. The paper also presents a workflow of estimating the structural geometries of features in two and three dimensions. The results of the structural feature analyses and computational time were compared between the open-source (ImageJ) and commercial image analysis software (Bruker Computed Tomography Analyzer). The commercial software was more computationally efficient, but the task-specific macros in open-source software enabled the user-desired automation in image processing and data extraction of desired structural features of comparable quality.

47 OTHER INSTRUMENTATION↗

Paw-Net: Stacking ensemble deep learning for segmenting scanning electron microscopy images of fine-grained shale samples

Segmentation of scanning electron microscopy (SEM) images is critical yet time-consuming for geological analyses, as it needs to differentiate the boundaries for different mineral objects to facilitate subsequent analyses, such as porosity calculation. Recently, various machine learning methods, especially convolutional neural networks (CNNs), have been explored to segment SEM images of fine-grained shale samples. However, we found that general CNNs do not yield optimal performance due to insufficient training data and imbalanced objects in SEM images. This work has revised the U-Net architecture, a popular approach for biomedical image analyses, by incorporating a loss function that addresses the imbalance issue. Furthermore, we used the ensemble learning method to train multiple models and combined the results to improve the overall performance of segmentation. We prepared 2162 sub-images from raw SEM images in our experiments and divided them into training, validation, and testing datasets. The overall results show that our method improves the average Intersection over Union (IOU) of mineral objects from 0.49 to 0.58, compared to the original U-Net model. Our method can clearly distinguish each object from others with boundaries, even in highly imbalanced images. Training our models takes less than three minutes using a single GPU, while manual labeling can take up to three hours for each image. Furthermore, the method helps geoscientists gain insights quickly and effectively by building neural network models from a small dataset of SEM images.

58 GEOSCIENCES↗

SREMI: Super-resolution electromagnetic imaging with single-channel ground-penetrating radar

High-resolution near-surface imaging has important applications in civil engineering, infrastructure inspection, military threat detection, geological characterization, and lunar and planetary exploration. Zero-offset, singlechannel ground penetrating radar (GPR) imaging is an established technique for near-surface target imaging and sensing but often suffers from low spatial resolution and imaging artifacts, especially of deep structures. In response, we formulate the GPR imaging as a dual-sparsity optimization problem, and develop a super-resolution electromagnetic imaging method based on a fast iterative shrinkage-thresholding algorithm. We develop our GPR imaging method in the framework of electromagnetic exploding-reflectors simulation theory, therefore the imaging method is computationally efficient. In this work, we demonstrate through synthetic and field data examples that our method can produce sharper, more reliable images with fewer artifacts compared with single-pass reverse-time migration GPR method, thus leading to improved near-surface interpretation and object identification.

58 GEOSCIENCES↗

Converting tabular data into images for deep learning with convolutional neural networks

Abstract Convolutional neural networks (CNNs) have been successfully used in many applications where important information about data is embedded in the order of features, such as speech and imaging. However, most tabular data do not assume a spatial relationship between features, and thus are unsuitable for modeling using CNNs. To meet this challenge, we develop a novel algorithm, image generator for tabular data (IGTD), to transform tabular data into images by assigning features to pixel positions so that similar features are close to each other in the image. The algorithm searches for an optimized assignment by minimizing the difference between the ranking of distances between features and the ranking of distances between their assigned pixels in the image. We apply IGTD to transform gene expression profiles of cancer cell lines (CCLs) and molecular descriptors of drugs into their respective image representations. Compared with existing transformation methods, IGTD generates compact image representations with better preservation of feature neighborhood structure. Evaluated on benchmark drug screening datasets, CNNs trained on IGTD image representations of CCLs and drugs exhibit a better performance of predicting anti-cancer drug response than both CNNs trained on alternative image representations and prediction models trained on the original tabular data.

59 BASIC BIOLOGICAL SCIENCES↗

Reconstructing magnetic deflections from sets of proton images using differential evolution

Proton imaging is a powerful technique for imaging electromagnetic fields within an experimental volume, in which spatial variations in proton fluence are a result of deflections to proton trajectories due to interaction with the fields. When deflections are large, proton trajectories can overlap, and this nonlinearity creates regions of greatly increased proton fluence on the image, known as caustics. The formation of caustics has been a persistent barrier to reconstructing the underlying fields from proton images. We have developed a new method for reconstructing the path-integrated magnetic fields, which begins to address the problem posed by caustics. Our method uses multiple proton images of the same object, each image at a different energy, to fill in the information gaps and provide some uniqueness when reconstructing caustic features. We use a differential evolution algorithm to iteratively estimate the underlying deflection function, which accurately reproduces the observed proton fluence at multiple proton energies simultaneously. We test this reconstruction method using synthetic proton images generated for three different, cylindrically symmetric field geometries at various field amplitudes and levels of proton statistics and present reconstruction results from a set of experimental images. Here, the method we propose requires no assumption of deflection linearity and can reliably solve for fields underlying linear, nonlinear, and caustic proton image features for the selected geometries and is shown to be fairly robust to noise in the input proton intensity.

47 OTHER INSTRUMENTATION↗

Fresnel diffraction imaging of surface nanostructure using coherent resonant x-ray scattering

We investigated surface nanostructures on an antiferromagnet MnBi 2 Te 4 using a novel imaging technique, direct (real)-space and real time coherent x-ray imaging (direct-CXI). This technique has provided new insights into antiferromagnetic textures, including the formation of anti-phase antiferromagnetic (AFM) domains and thermal dynamics of AFM domains and domain walls. While this method produces real-space images of AFM textures without requiring a complex imaging retrieval process, its underlying imaging mechanism has not been fully understood, limiting a deep understanding of AFM textures and the information they contain. By investigating the well-defined structural characteristics of the nanostructures fabricated on MnBi 2 Te 4 ⁠, we elucidate the imaging principle of this novel technique. We find that the observed images can be well explained by the Fresnel diffraction integral. Using a simple model from classical optics, our calculations successfully reproduce the experimentally observed images of the nanostructures. This demonstrates that direct-CXI not only provides straightforward real-space imaging but also contains phase information through its Fresnel diffraction integral.

36 MATERIALS SCIENCE↗

PyZebrascope: An Open-Source Platform for Brain-Wide Neural Activity Imaging in Zebrafish

Understanding how neurons interact across the brain to control animal behaviors is one of the central goals in neuroscience. Recent developments in fluorescent microscopy and genetically-encoded calcium indicators led to the establishment of whole-brain imaging methods in zebrafish, which record neural activity across a brain-wide volume with single-cell resolution. Pioneering studies of whole-brain imaging used custom light-sheet microscopes, and their operation relied on commercially developed and maintained software not available globally. Hence it has been challenging to disseminate and develop the technology in the research community. Here, we present PyZebrascope, an open-source Python platform designed for neural activity imaging in zebrafish using light-sheet microscopy. PyZebrascope has intuitive user interfaces and supports essential features for whole-brain imaging, such as two orthogonal excitation beams and eye damage prevention. Its camera module can handle image data throughput of up to 800 MB/s from camera acquisition to file writing while maintaining stable CPU and memory usage. Its modular architecture allows the inclusion of advanced algorithms for microscope control and image processing. As a proof of concept, we implemented a novel automatic algorithm for maximizing the image resolution in the brain by precisely aligning the excitation beams to the image focal plane. PyZebrascope enables whole-brain neural activity imaging in fish behaving in a virtual reality environment. Thus, PyZebrascope will help disseminate and develop light-sheet microscopy techniques in the neuroscience community and advance our understanding of whole-brain neural dynamics during animal behaviors.

59 BASIC BIOLOGICAL SCIENCES↗

Using AI Segmentation Models to Improve Foreign Body Detection and Triage from Ultrasound Images

Medical imaging can be a critical tool for triaging casualties in trauma situations. In remote or military medicine scenarios, triage is essential for identifying how to use limited resources or prioritize evacuation for the most serious cases. Ultrasound imaging, while portable and often available near the point of injury, can only be used for triage if images are properly acquired, interpreted, and objectively triage scored. Here, we detail how AI segmentation models can be used for improving image interpretation and objective triage evaluation for a medical application focused on foreign bodies embedded in tissues at variable distances from critical neurovascular features. Ultrasound images previously collected in a tissue phantom with or without neurovascular features were labeled with ground truth masks. These image sets were used to train two different segmentation AI frameworks: YOLOv7 and U-Net segmentation models. Overall, both approaches were successful in identifying shrapnel in the image set, with U-Net outperforming YOLOv7 for single-class segmentation. Both segmentation models were also evaluated with a more complex image set containing shrapnel, artery, vein, and nerve features. YOLOv7 obtained higher precision scores across multiple classes whereas U-Net achieved higher recall scores. Using each AI model, a triage distance metric was adapted to measure the proximity of shrapnel to the nearest neurovascular feature, with U-Net more closely mirroring the triage distances measured from ground truth labels. Overall, the segmentation AI models were successful in detecting shrapnel in ultrasound images and could allow for improved injury triage in emergency medicine scenarios.

47 OTHER INSTRUMENTATION↗

Ultra-Fast Electron Microscopic Imaging of Single Molecules With a Direct Electron Detection Camera and Noise Reduction

Time-resolved imaging of molecules and materials made of light elements is an emerging field of transmission electron microscopy (TEM), and the recent development of direct electron detection cameras, capable of taking as many as 1,600 fps, has potentially broadened the scope of the time-resolved TEM imaging in chemistry and nanotechnology. However, such a high frame rate reduces electron dose per frame, lowers the signal-to-noise ratio (SNR), and renders the molecular images practically invisible. Here, we examined image noise reduction to take the best advantage of fast cameras and concluded that the Chambolle total variation denoising algorithm is the method of choice, as illustrated for imaging of a molecule in the 1D hollow space of a carbon nanotube with ~1 ms time resolution. Through the systematic comparison of the performance of multiple denoising algorithms, we found that the Chambolle algorithm improves the SNR by more than an order of magnitude when applied to TEM images taken at a low electron dose as required for imaging at around 1,000 fps. Open-source code and a standalone application to apply Chambolle denoising to TEM images and video frames are available for download.

47 OTHER INSTRUMENTATION↗

Simulation studies of a full-ring, CZT SPECT system for whole-body imaging of 99m Tc and 177 Lu

Single photon emission computed tomography (SPECT) is an imaging modality that has demonstrated its utility in a number of clinical indications. Despite this progress, a high sensitivity, high spatial resolution, multi-tracer SPECT with a large field of view suitable for whole-body imaging of a broad range of radiotracers for theranostics is not available. With the goal of filling this technological gap, we have designed a cadmium zinc telluride (CZT) full-ring SPECT scanner instrumented with a broad-energy tungsten collimator. The final purpose is to provide a multi-tracer solution for brain and whole-body imaging. Our static SPECT does not rely on the dual- and the triple-head rotational SPECT standard paradigm, enabling a larger effective area in each scan to increase the sensitivity. We provide a demonstration of the performance of our design using a realistic model of our detector with simulated body-sized phantoms filled with 99m Tc and 177 Lu. Our SPECT design can resolve 7.9 mm rods for 99m Tc (140 keV) and 9.5 mm for 177 Lu (208 keV) in a hot-rod Derenzo phantom with a 3-min exposure and reach an image contrast of 78% for 99m Tc and 57% for 177 Lu using the NEMA IQ phantom with a 6-min exposure. Our modified scatter correction shows an improved contrast-recovery ratio compared to a standard correction. In this paper, we demonstrate the good performance of our design for whole-body imaging purposes. This adds to our previous demonstration of improved qualitative and quantitative 99m Tc imaging of brain perfusion and 123 I imaging of dopamine transport with respect to state-of-the-art NaI dual-head cameras. We show that our design provides similar IQ and contrast to the commercial full-ring SPECT VERITON for 99m Tc. Regarding 177 Lu imaging of the 208 keV emissions, our design provides similar contrast to that of other state-of-the-art SPECTs with a significant reduction in exposure. In conclusion, the high sensitivity and extended energy range up to 250 keV makes our SPECT design a promising alternative for clinical imaging and theranostics of emerging radionuclides.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Automated Scoring of Morphological Changes in Images of Pentaerythritol Tetranitrate

Recent advances in characterization techniques that generate large datasets of material microstructure images require robust, automated image-processing. We applied an unsupervised anomaly detection method called feature anomaly detection system (FADS) to automatically detect and quantify microstructure changes in images of the explosive pentaerythritol tetranitrate (PETN) aged at various temperatures. We demonstrated the FADS approach on two-dimensional images extracted from computed tomography scans, but the same technique can be readily applied to other imaging modalities. FADS calculates anomaly scores on the basis of differences in filter activations of nominal and test data in pretrained convolutional neural networks. The FADS scores successfully differentiated between pristine PETN and PETN aged at a temperature where material coarsening occurred. Morphological metric analysis of segmented images verified observed trends in FADS scores as a function of aging temperature and aging time, specifically by calculating volume fractions, specific boundary lengths, two-point correlation functions, and local thicknesses. Here, the FADS technique has two important advantages compared to traditional morphological analysis: First, it uses grayscale images as input, rather than images that are segmented to separate the appropriate phases; and second, FADS scores capture any type of changes among image sets, rather than requiring prior knowledge or selection of a relevant set of metrics.

Accelerated aging↗

Deep learning-based noise filtering toward millisecond order imaging by using scanning transmission electron microscopy

Application of scanning transmission electron microscopy (STEM) to in situ observation will be essential in the current and emerging data-driven materials science by taking STEM’s high affinity with various analytical options into account. As is well known, STEM’s image acquisition time needs to be further shortened to capture a targeted phenomenon in real-time as STEM’s current temporal resolution is far below the conventional TEM’s. However, rapid image acquisition in the millisecond per frame or faster generally causes image distortion, poor electron signals, and unidirectional blurring, which are obstacles for realizing video-rate STEM observation. Here we show an image correction framework integrating deep learning (DL)-based denoising and image distortion correction schemes optimized for STEM rapid image acquisition. By comparing a series of distortion corrected rapid scan images with corresponding regular scan speed images, the trained DL network is shown to remove not only the statistical noise but also the unidirectional blurring. This result demonstrates that rapid as well as high-quality image acquisition by STEM without hardware modification can be established by the DL. The DL-based noise filter could be applied to in-situ observation, such as dislocation activities under external stimuli, with high spatio-temporal resolution.

47 OTHER INSTRUMENTATION↗

Classification of computed thermal tomography images with deep learning convolutional neural network

Thermal tomography (TT) is a computational method for the reconstruction of depth profile of the internal material defects from Pulsed Infrared Thermography (PIT) nondestructive evaluation. Here, the PIT method consists of recording material surface temperature transients with a fast frame infrared camera, following thermal pulse deposition on the material surface with a flashlamp and heat diffusion into material bulk. TT algorithm obtains depth reconstructions of thermal effusivity, which has been shown to provide visualization of the subsurface internal defects in metals. In many applications, one needs to determine the defect shape and orientation from reconstructed effusivity images. Interpretation of TT images is non-trivial because of blurring, which increases with depth due to the heat diffusion-based nature of image formation. We have developed a deep learning convolutional neural network (CNN) to classify the size and orientation of subsurface material defects in TT images. CNN was trained with TT images produced with computer simulations of 2D metallic structures (thin plates) containing elliptical subsurface voids. The performance of CNN was investigated using test TT images developed with computer simulations of plates containing elliptical defects, and defects with shapes imported from scanning electron microscopy images. CNN demonstrated the ability to classify radii and angular orientation of elliptical defects in previously unseen test TT images. We have also demonstrated that CNN trained on the TT images of elliptical defects is capable of classifying the shape and orientation of irregular defects.

42 ENGINEERING↗

Forward modeling fluctuations in the DESI LRGs target sample using image simulations

We use the forward modeling pipeline, Obiwan, to study the imaging systematics of the Luminous Red Galaxies (LRGs) targeted by the Dark Energy Spectroscopic Instrument (DESI). Imaging systematics refers to the false fluctuation of galaxy densities due to varying observing conditions and astrophysical foregrounds corresponding to the imaging surveys from which DESI LRG target galaxies are selected. We update the Obiwan pipeline, which we previously developed to simulate the optical images used to target DESI data, to further simulate WISE images in the infrared. This addition allows simulating the DESI LRGs sample, which utilizes WISE data in the target selection. Deep DESI imaging data combined with a method to account for biases in their shapes is used to define a truth sample of potential LRG targets. We inject these data evenly throughout the DESI Legacy Imaging Survey footprint at declinations between -30 and 32.375 degrees. We simulate a total of 15 million galaxies to obtain a simulated LRG sample (Obiwan LRGs) that predicts the variations in target density due to imaging properties. We find that the simulations predict the trends with depth observed in the data, including how they depend on the intrinsic brightness of the galaxies. We observe that faint LRGs are the main contributing source of the imaging systematics trend induced by depth. We also find significant trends in the data against Galactic extinction that are not predicted by Obiwan. These trends depend strongly on the particular map of Galactic extinction chosen to test against, implying systematic contamination in the Galactic extinction maps is a likely root cause (e.g., Cosmic-Infrared Background, dust temperature correction). We additionally observe a morphological change of the DESI LRGs population evidenced by a correlation between OII emission line average intensity and the size of the z-band PSF. This effect most likely results from uncertainties in background subtraction. The detailed findings we present should be used to guide any observational systematics mitigation treatment for the clustering of the DESI LRGs sample.

79 ASTRONOMY AND ASTROPHYSICS↗